GENERAL NOTES:
FOR MECHANICAL PIPING NOTES,
LEGENDS, AND ABBREVIATIONS, SEE
SHEETS M-900001B THRU M-900007B.
FOR ADDITIONAL TRANSMITTERS AND
INDICATORS, SEE SHEETS MP900601B
THRU MP900608B.
REFER TO SHEET A-900008B FOR HEMP
SHIELD.
KEYNOTES:
A.
B.
C.
14" DIA DOWN W/ METAL EXPANSION
JOINT FOR PIPING SEE DETAIL 4 ON
SHEET MP900502B.
REFER TO SPECIFICATION SECTION 43
21 29. 01 00 FOR FLOW METER SIZE.
B
C
D
E
E.2
7 8 9 10
MP900302B
MP900302B
GCP-90031001A GCP-90031001B
GCP-90031001C GCP-90031002A
GCP-90031002B
12"ø GCS
AS-90031001
GMU-90031001
ET-90031001
H X
-9 A
H X
-9 B
H X
-9 C
12"ø WWC 12"ø WWC 12"ø WWC
12"ø GCS 12"ø GCS 12"ø GCS
FM-90031004
FM-90031003
FM-90022001
UH-90041001 UH-90041002
1 1/2"ø GHR 1 1/2"ø GHS (TYP)
UH-90041003FCU-90041008
4"ø GHS 4"ø GHR
1 1/2"ø GCR
1 1/2"ø GCS
1 1/4"ø GHS 1 1/4"ø GHR
12"ø GCR12"ø GCR12"ø GCR
12"ø WWD 12"ø WWD
"ø
W W
D
"ø
W W
C
12"ø WWD
8"ø GHS 8"ø GHR
10"ø ECWR 10"ø ECWS
14"ø WWC
4"ø GHS 4"ø GHR
10"ø GCS
6"ø GCS
10"ø GCR
10"ø GCS 10"ø GCR
4"ø GHR 4"ø GHS
1"ø GHR
1"ø GHS 8"ø 8"ø 8"ø
8"ø GCS8"ø GCS8"ø GCS
"ø
W W
C "ø
W W
C
HP-90022001 HP-90022002
W/ GMP-90031001A&B
4"ø GHR 4"ø GHS
6"ø GCR 6"ø GCS
12"ø WWC
20"ø WWC
1 1/4"ø FOR
1 1/4"ø FOS
MECH ROOM 1
CORR
CORR
6"ø GCS10"ø10"ø
F M
-9
CSF-90031001
"ø
G C
S
"ø
4"ø GHR 4"ø GHS
MP900302B
12"ø GCS
12"ø GCS
6"ø GCS
8"ø GCR8"ø GCR8"ø GCR
"ø
W W
D
"ø
W W
D
"ø
W W
D
MP900503B
(TYP)
MP900501B
(TYP)
MP900505B
MP900505B
MP900501B
(TYP)
MP900503B
SEE DRAWING D-900102B
3/4"ø GHS
3/4"ø GHR 3/4"ø GHS 3/4"ø GHR
1 1/4"ø GHR
1 1/4"ø GHS
1-1/4" FOS/FOR FOR
TEMPORARY USE
1-1/4" FOS/FOR FOR
FUTURE CONNECTION
TO LPP
SEE D-900102B
MP900503B
3/4"ø GHS 3/4"ø GHR
3/4"ø HTS 3/4"ø HTR
1"ø
WWF-90031002
10"ø (TYP)
MP900303B
FM-90035001B
(LINE SIZE)
A B
C D
E
LES
D E
P
A R
T M
E N
T O
F D
E F
E
N S
E
MISSIL
E D
E F
E N
S E
A
G
ENCY
D ra w in g
F ile
N a m e
D w g S c a le
P lo t S c a le
D a te
D ra w n
R E
S
ID
E N
T E
N G
IN
E
E R
P R
IM
E
C O
N T
R A
C T
O R
S u b m it te d
D e s ig n e d
R e v ie w e d
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
A N
C H
O R
A G
E A
L A
S K
A
C O
R P
S O
F E
N G
IN
E
E R
S
D a te
S T
A T
E C
IT
Y
C O
N T
R A
C T
O R
C O
N T
R A
C T
N O
R e c o m m e n d e d
A p p ro v e d
Reference number:
HGFEDCBA
A S
N O
T E
D
P L O
T T
E D
O N
US Army Corps of Engineers ®
Alaska District
M D
A
C L R
FOR OFFICIAL USE ONLY
A E
C O
M
T E
T R
A T
E C
H J
V
NOT FOR CONSTRUCTION
/2
/2
:4 :5
A
M C
U s e rs
\d e c a s tr o c \D o c u m e n ts
\C L R
L R
D R
M
C F
M
E C
H c h e ls e a .d e c a s tr o .r v t
RTA MP900402B
M E
C H
A N
IC
A
L P
IP
IN
G E
N L A
R G
E D
P L A
N
S H
E E
T
O F
L O
N G
R A
N G
E D
IS
C
R
IM
IN
A
T
IO
N R
A D
A R
C L
E A
R A
F S
A
L A
S K
A
P .W
U
:1
C .D
E C
A S
T R
O
N .P
A T
E L
W K
B -1
-R
-0
.1
.1
C O
N S
T R
U C
T
IO
N P
A C
K A
G E
V O
L U
M E
B
T N
CL
R_
LR
DR
_M
CF
_M
EC
H_
A F
-1
-3 -0
PLAN NORTH
SCALE:
0 4' 8'
1/4" = 1' - 0"
4' 8'
S E
E S
H E
E T
M P
B
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUTS/NOTES ARE INCHES UNLESS OTHERWISE NOTED
1/4" = 1'-0"MP900402B
1 LEVEL 1 MECHANICAL PIPING ENLARGED PLAN B
S y m
A c ti o n
D e s c ri p ti o n
D a te
A p p v d
F
R E
A D
Y T
O A
D V
E R
T
IS
E S
U B
M
IT
T A
L
.1
.1
B T
N
A M
A M
E N
D M
E N
T
.0
.2
B T
N
10 1010
File details come from the government source that posted it. Updated .