This document is a specification and qualification package for Kingspan Insulated Panels' KS Shadowline insulated metal wall panel system for the Mansfield Air National Guard Building 403 project in Mansfield, Ohio. The package includes manufacturer qualifications, installation contractor recognition, product specifications, warranty terms, installation drawings, and material specifications for coatings and sealants.
Kingspan Group is a global manufacturer of insulated roof, wall, and façade systems headquartered in Ireland with over 5,500 employees worldwide. The company operates North American offices in California, Florida, Ohio, and Canada, and provides insulated metal panels for commercial, industrial, and cold storage applications. The KS Shadowline product features vertical or horizontal orientation with 24" to 42" widths, thicknesses ranging from 2" to 6", and R-values approximately 7.2 to 8.25 per inch. The panels are manufactured with foamed-in-place polyurethane insulation between metal facings, utilizing Fluropon 70% PVDF coatings from Sherwin-Williams in various color options. The limited warranty covers XX years with no dollar limitation for repair or replacement, contingent upon proper installation per Kingspan guidelines, regular maintenance including caulking replacement, owner inspection before installation, and timely defect reporting within 30 days. The warranty excludes exterior finish coatings, weathertightness, and corrosion-related damage. Installation contractor Alloyd Sheet Metal & Insulation Company is recognized by Kingspan for successful installation of similar panels. Supporting materials include butyl sealant specifications, NovaFlex metal roof adhesive sealant with multiple color options, detailed wall section drawings, and elevation plans showing panel integration with structural elements, CMU backup walls, windows, doors, and penetrations.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.kingspanpanels.us www.kingspanpanels.ca
Manufacturer Qualification
| Kingspan | Group | are | global | leaders | in | the | design | and | manufacture | of | insulated | roof, | architectural | wall | and | façade | systems | that |
| offer | designers | and | architects | unlimited | choice | to | create | energy‐efficient | buildings | that | deliver | 'signature' | architectural | and | ||||
| aesthetic | impact. |
Fact sheet
| Kingspan | is | recognized | throughout | the | construction | industry | for | its | commitment | to | innovation, | design, | quality | and | technical | ||||
| expertise. | Across | a | wide | range | of | sectors | within | the | industry, | Kingspan’s | integrated | approach | to | building | envelope | solutions | |||
| has | made | them | first | choice | in | meeting | the | specialist | needs | of | architects, | specifiers, | developers | and | owners. | Operating | on | an | |
| International | level | Kingspan | has | manufacturing | and | distribution | operations | throughout | Europe, | the | Far | East, | the | United | |||||
| States, | and | Canada. | Kingspan | products | are | designed | to | reduce | capital | costs | and | improve | the | quality | and | working | environment | ||
| in | both | new | and | refurbished | buildings. | Many | products | can | be | integrated | on | the | same | project | offering | the | client | improved | build |
| speed, | exceptional | thermal | performance | and | undisputed | fire‐safe | construction. | Through | its | continued | investment | in | research | ||||||
| and | development, | its | recognized | commitment | to | quality | and | performance | Kingspan | confidently | looks | forward | to | a | future | of | |||
| continued | service | to | the | construction | industry | world‐wide |
History
| 1970 | ‐ | 1980 | The | Group | was | founded | in | 1972 | as | a | small | family | business | by | Eugene | and | Brendan | Murtagh | (both | currently |
| members | of | the | Board | of | Directors). | The | Group | was | initially | involved | in | the | manufacture | of | metal | cladding | and | roll | formed | |
| structural | sections. | Later, | Kingspan | layered | the | foundations | for | its | current | full | environmental | offering |
Listings Kingspan is quoted on the Irish Stock Exchanges (Symbol: KSP:ISE)
Employees Over 5,500 people are employed by Kingspan world‐wide, including approximately 3,000 people in an operational or technical capacity.
Head office and registered office
Kingspan Group Plc Dublin Road, Kingscourt,Co. Cavan. Ireland.
Tel: +353 (0) 42 9698000 Fax: +353 (0) 42 9667501
North American Offices
Kingspan Insulated Panels
Kingspan Benchmark 2000 Morgan Road 726 Summerhill Drive 720 Marion Road Modesto, CA 95358, USA Deland, FL 32724, USA Columbus, OH 43207, USA Tel: +1 800 377 5110 Fax: +1 209 531 9099 Tel: +1 877 638 3266 Fax: +! 386 626 6884 Tel: +1 614-444-0110 Fax: +1 614-444-7759
Kingspan Insulated Panels 12577 Coleraine Drive
5202 – 272nd Street
Caledon, ON L7E 3B5, Canada Langley, BC V4W 1S3, Canada Tel +1 905-951-5600 Fax +1 905-951-3944 Tel +1 604-607-1101 Fax +1 604-607-1142
Mansfield ANG Building 403 - Mansfield, OH - KS Series
L i n e 3 0 9 0 7 4 2 1 3 Q u a l i f i c a t i o n p a r a g r a p h # 1 . 5 . 3 joel Highlight
To Whom It May Concern, Kingspan is a leading manufacturer and has demonstrated a successful history of providing Insulated Metal Wall Panels and accessories for over (20) years. Kingspan is a member of the Metal Construction Association (MCA), and all materials are manufactured in conformance with MCA guidelines and tolerances.
Regards, Royce Chitty Engineer Technician Technical Services
Mansfield ANG Building 403 - Mansfield, OH - KS Series
726 Summerhill Dr., Deland, FL 32724, USA 386-626-6789 p 386-626-6887 f
2000 Morgan Rd., Modesto, CA 95358, USA 209-531-9091 p 209-531-9055 f
720 Marion Road (P.O. Box 07928) Columbus, OH 43207, USA 614-444-0110 p 614-444-7759 f
12557 Coleraine Dr., ON L7E 3B5, Canada 905-951-5600 p 905-951-3944 f
5202-272nd St., Langley, B.C. V4W 1S3, Canada 604-607-1101 p 604-607-1142 f
May 3, 2021
Mr. Tom Wills Alloyd Sheet Metal & Insulation Company 5734 Webster St.
Dayton, OH 45413
RECOGNITION LETTER
Dear Tom:
This letter is written to document our recognition of Alloyd Sheet Metal & Insulation Company’s installation of Kingspan insulated panels of similar size and scope on many projects with great success. Alloyd Sheet Metal & Insulation Company’s knowledge of Kingspan panel products and the quality installation that is always completed continuously makes for a successful project.
If any other information is required, please contact me.
Best regards, KINGSPAN INSULATED PANELS
Alex R. Detmer
Alex R. Detmer Manager Field Technical Services
Line 310 Section 074213 Qualification of Installation Contractor 1.5.4
Final 11/16 11217387.1
LIMITED WARRANTY – PANELS
(NO DOLLAR LIMITATION FOR REPAIR OR REPLACEMENT)
PROJECT: ___________________________ OWNER: ________________________
CUSTOMER: ________________________
DATE OF SHIPMENT: ___________________________
KINGSPAN JOB NO.: ___________________________
PLANT LOCATION: ___________________________
PANEL TYPE(S): ___________________________
Kingspan Insulated Panels Inc. (or Kingspan Insulated Panels Ltd. for projects located in Canada), hereinafter referred to as “Kingspan”, shall extend a limited warranty for a period of (XX) year(s) on the insulated panels furnished by Kingspan for the project referenced above subject to the following terms and conditions:
TERMS AND CONDITIONS
I. WARRANTY DESCRIPTION AND DURATION
Kingspan warrants to the owner of the building (“Owner”) that the panels covered hereunder will be free from defects in material and workmanship under normal use and service for the period noted above.
Panels, if properly installed, will not show evidence of excessive deflection or delamination under conditions within panel design limits determined by Kingspan. The warranty period commences on the date of substantial completion, or six months from date of shipment, whichever occurs first. Exterior finish coating is excluded from this limited warranty; see separate finish warranty available upon request from Kingspan. A separate weathertightness limited warranty may be available at an additional cost. This warranty does not include any matter relating to corrosion.
II. OWNER’S OBLIGATIONS
1. Owner, or its designated contractor, shall, prior to installation, inspect the material received from Kingspan, and shall forthwith notify Kingspan of any nonconformity of the material.
Installation of the material shall constitute acceptance of the material as in conformity with the material ordered.
2. Caulking and sealing materials shall be maintained and replaced as necessary as outlined in the maintenance guidelines.
Mansfield ANG Building 403 - Mansfield, OH - KS Series
Line 312 074213 Warranty Paragraph 1.8
Line 341 074213 Closeout Submittals 1.8
11217387.1
3. Owner shall periodically clean the panels to remove debris, silt and other contaminants and obstructions to flow of runoff. This cleaning shall be performed at least as frequently as outlined in the maintenance guidelines.
4. Owner must provide Kingspan free access to all panels on the subject building during normal business hours to conduct any and all investigations and repairs.
5. Any claim arising from this limited warranty for any cause whatsoever shall be deemed WAIVED by Owner unless written notice thereof is given to the Plant Manager of the Kingspan plant location listed above within the earlier of (a) thirty (30) days after discovery of claimed defect, or (b) thirty (30) days from time such defect should have been discovered after exercise of reasonable diligence, and within the warranty period. Owner’s notice shall include Kingspan’s order number, date of shipment and date of panel installation. On request, Owner must provide duly authenticated records describing the defect which were made in the ordinary course of business contemporaneously with the events noted thereon. Owner shall, on demand, present evidence that establishes any claimed defects are due to a breach of the limited warranty stated herein, and that the Owner’s obligations under the limited warranty have been fulfilled.
6. Owner must install, use and maintain the panels strictly in accordance with the instructions and recommendations contained in Kingspan’s installation and maintenance guidelines and accepted industry practices. Owner understands and agrees that Kingspan’s written instructions and recommendations contained in Kingspan’s installation and maintenance guidelines and accepted industry practices control, and that it shall not rely on any oral statements or recommendations of Kingspan personnel. Owner acknowledges that any shop drawings prepared by Kingspan are solely for the purpose of finalizing Kingspan’s bill of materials, and are not for reliance by Owner or Installer.
7. Kingspan shall be given reasonable opportunity to inspect the installation prior to Owner making or causing to be made any repairs to the panels. All repair attempts made must be pre-approved in writing by Kingspan. Owner agrees to reimburse Kingspan for all investigation costs incurred by Kingspan for claims made by Owner which are determined not to be valid hereunder. No components or materials shall be returned to Kingspan without Kingspan’s inspection and approval and receipt from Kingspan of written shipping instructions.
III. EXCLUSIVE REMEDY
1. If it is determined to Kingspan’s reasonable satisfaction, upon inspection by Kingspan, that a valid warranty claim has been made pursuant to the terms of this limited warranty, Kingspan shall, at its sole discretion, (i) provide replacements for any defective panels, (ii) repair the defective panels (subject always to such repair obligation being limited solely to the cost of material and labor), or (iii) pay to the Owner an amount equal to the price originally paid for the defective panels by Customer. The warranty period for any repaired or replaced panels shall be limited to the unexpired warranty period for the originally supplied panels.Liability under this Limited Warranty shall be limited to the actual cost of the warranty repair work, but is not limited to the original cost of the material supplied by Kingspan. Kingspan shall not be liable for claims resulting from improper or incorrect installation of Kingspan’s panels.
Kingspan’s sole liability for breach of warranty shall be as set forth in this Section III.1.
2. Should the product covered under this limited warranty be discontinued, Kingspan reserves the right to substitute a product of equal quality or price at its discretion. It is understood and
11217387.1 accepted by Owner that normal exposure to the elements may preclude a perfect color match between the original and any replacement material.
3. Owner and Customer hereby WAIVE all remedies not expressly provided herein, including, but not limited to, losses due to damage to property, any direct or indirect losses or costs, or incidental or consequential damages for loss of use, loss of revenue or loss of profit. Such waiver shall apply even if Kingspan has been advised of the possibility of such claims, losses or damages.
IV. WARRANTY LIMITATIONS
1. THE WARRANTY ISSUED TO OWNER HEREUNDER IS EXCLUSIVE AND IN LIEU
OF ANY AND ALL OTHER WARRANTIES, CONDITIONS, RIGHTS OR REMEDIES,
EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE TO OWNER OR CUSTOMER,
INCLUDING THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE AND THE CONDITION OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. KINGSPAN HEREBY DISCLAIMS, AND
OWNER AND CUSTOMER HEREBY WAIVE, ANY LIABILITY OF KINGSPAN IN
CONTRACT OR TORT, STRICT OR OTHERWISE, OR UNDER ANY STATUTE FOR
DAMAGES, DIRECT OR CONSEQUENTIAL, RESULTING FROM A DEFECT IN
DESIGN, MATERIAL, WORKMANSHIP, OR MANUFACTURE, WHETHER OR NOT
OCCASIONED BY KINGSPAN’S NEGLIGENCE.
2. This limited panel warranty will be null and void if one or more of the following conditions exist, whether or not such conditions result from or are occasioned by the negligence or fault of any other party:
a. Failure of Owner to fulfill his obligations as set forth in Section II above.
b. Improper installation, including but not limited to non-compliance with information set forth in current Kingspan installation guidelines, Kingspan shop drawings or Kingspan approved shop drawings, non-conformance to SMACNA principles for sheet metal practices, facing or changing the factory finished color by any means such as adhering a membrane to the facing, or installation of panels with any accessories or by any means not approved in writing by Kingspan.
c. Alterations made to the panels without prior authorization from Kingspan, including but not limited to, structures, fixtures, or utilities being placed upon or attached to the panels, or attachments of signs, the installation of vents or manual perforations or penetrations such as skylights or solar panels or the addition or relocation of curb units, smoke hatches, HVAC units, electrical or pip penetrations or ventilators.
d. Damage caused by settlement, expansion or deflection of structural load-bearing members or movement of roof, walls, steel frame or secondary structural members of building systems or equipment including building foundations, or vibrating, reciprocating or rotating machinery.
e. Damage resulting from natural or man-made disasters such as tornadoes, hurricanes, hail, floods, cyclones, sand storms, earthquakes, lightning, fire, acts of war, vandalism or terrorism, or other force majeure events.
11217387.1
f. Damage resulting from acts of negligence including but not limited to improper storage, shipping and/or handling, accident or misuse, aggressive cleaning products or methods, etc.
g. Damage resulting from falling objects, projectiles, however propelled, foot traffic, recreational activities, or storage of material of any kind in contact with the panels or other improper use of the panels.
h. Changes in building usage or utilization without prior written consent of Kingspan.
i. Standing water (ponding or pooling) or inadequately sealed overlaps allowing retention of water or other contaminants.
j. Corrosion of any sort, including corrosion resulting from drainage, roof top equipment, leaky gutters, exposure to marine (salt water) atmosphere, atmospheric contaminants or contaminants generated inside the building, including moisture build-up due to inadequate or poor ventilation of interior. The fact that contaminants may not have been identified or existent at time of installation shall not obligate Kingspan under the provisions of this limited warranty.
k. Movement or deterioration of metal components and/or dissimilar metals in direct contact with or adjacent to the panels unless such components are an integral part of the panel system and have been approved or designated by Kingspan in writing as a part of the panel system purchased, or deterioration caused by contact with wet, green or treated lumber or due to direct or indirect contact with corrosive materials.
l. Failure of any materials, assemblies or components furnished by others whether or not identified to Kingspan at the time of entry into the contract with Customer for the sale of panels.
m. Fair wear and tear, misuse, willful damage, negligence, abnormal working conditions, default or breach of any statutory duty by Owner or its contractors, failure to follow Kingspan’s instructions, or misuse of the panels.
n. Any change in the atmospheric conditions at the site where the Project is located from those conditions notified to Kingspan on the date of Kingspan’s entry into the contract with Customer for the panels, or any atmospheric conditions not in compliance with the established air quality standards set forth in the U.S. Clean Air Act or any and all other applicable laws of any federal, provincial, state, municipal or local governmental body.
o. Repairs or attempted repairs by persons other than Kingspan or its appointed agents, or the occurrence of any events which are commonly covered by a building insurance policy.
p. Exposure to continuous temperatures howsoever caused greater than 180ºF / 82ºC.
q. The performance of any touch-up paint or overpaint used on the panels before, during or after erection.
r. The panels being in direct contact with, or run off from, materials with advance corrosion.
11217387.1
s. The panels being removed and/or installed in a different location after the original installation.
3. The Owner’s rights, and entitlement to bring a claim or otherwise make recovery under this limited warranty (and Kingspan’s liability) shall be subject to the Customer, the Customer’s sub-contractors and the Owner (including Owner’s agents and representatives) having followed Kingspan’s technical documents in all respects, but particularly in relation to design loads, supporting spans, fastener spacing and type, detail installation design and fixing.
Where not covered by Kingspan’s latest published product literature, then such parties shall have followed best practice and all reasonable skill and care have been employed.
4. The limited warranty is given by Kingspan in reliance upon and upon condition of the accuracy of the information provided by the Customer and/or Owner. Any inaccuracy in such information provided by the Customer and/or Owner shall result in Kingspan ceasing to be liable or having any responsibility under this limited warranty and the Owner shall not be entitled to make a claim and/or recovery or otherwise commence any legal action against Kingspan under or in connection with this limited warranty.
5. Kingspan shall have no liability under this limited warranty if a defect or fault in the panels results from any drawing, design or specification supplied by the Customer or Owner or a failure to comply with Kingspan’s design guidelines issued from time to time.
6. The internal and external environmental conditions prevailing at the time of installation of the goods are deemed “designed for” and then only when full and accurate audited information is available to Kingspan. Kingspan will not be liable for any defect or failure which may occur to the panels due to change of building usage or variations in atmospheric conditions.
7. Gutter assemblies (gutter components) of any kind are excluded from this limited warranty.
V. TRANSFERS, ASSIGNMENTS AND REPRESENTATIONS
1. This Limited Warranty is extended to the above named Owner only and is non-transferable and assignable only to future owners of the Project on which the panels have been originally installed, subject, in all instances, to the terms of this Limited Warranty including the conditions and limitations hereof.
VI. TERMINATION
1. Kingspan reserves the right to terminate this Limited Warranty except with respect to orders which it has already accepted, upon giving of written notice thereof.
VII. ENTIRE AGREEMENT/MERGER
1. Oral statements made by Kingspan’s representatives and written descriptions of the products appearing elsewhere than in this Limited Warranty are not warranties and shall not be relied upon by Owner. This writing constitutes the final, complete and exclusive expression of the terms of the parties’ agreement. Any modifications hereof, to be effective, shall be in writing, shall expressly refer to this Limited Warranty, and shall be signed by an authorized representative of Kingspan.
2. Kingspan will not participate in any claims or pay any claims until the full contract price for all work performed and materials furnished is received by Kingspan, unless the claim of an
11217387.1 alleged failure of the warranted product is made prior to completion of the installation. This requirement also includes payment to Kingspan for the additional cost of this Limited Warranty, if any. Kingspan’s obligations under this Limited Warranty are conditioned on compliance with all of the terms of the contract of sale between Kingspan and Customer, including the terms of this Limited Warranty.
3. Kingspan’s failure at any time to enforce any of the terms and / or conditions stated herein shall not be construed to be a waiver of those provisions.
4. In the event of a material breach by the Owner of any of the conditions of this Limited Warranty, Kingspan shall have no liability for any panel failure claims.
5. The laws of the state of Florida shall govern the construction, interpretation and performance of this limited warranty, except for projects located in Canada which shall be governed by the laws of the Province of Ontario in each case without regard to the laws of such jurisdiction relating to conflicts of laws. In the event that any provision shall be deemed illegal, unenforceable or null and void, all remaining provisions shall remain in effect. Any controversy or dispute arising out of or related to this Limited Warranty shall be addressed and resolved in accordance with the process set forth in Kingspan’s Sales Terms and Conditions (U.S.) available at [URL] (the “Sales Terms”).
6. In case any one or more of the provisions or parts of a provision contained herein are, for any reason, held to be invalid, illegal or unenforceable in any respect in any jurisdiction, such invalidity, illegality or unenforceability will not affect any other provision or part of a provision hereof or any other jurisdiction, but this Limited Warranty will be reformed and construed in any such jurisdiction as if such invalid or illegal or unenforceable provision or part of a provision had never been contained herein and such provision or part will be reformed so that it would be valid, legal and enforceable to the maximum extent permitted in such jurisdiction.
7. The parties acknowledge that they have requested that this Limited Warranty and all documents relating hereto be drawn up in the English language, and the English language shall prevail. Les parties reconnaissent qu'elles ont exigés que les présentes conditions de ventes et tous documents qui y sont afférents soient rédigés en langue anglaise et le langue anglaise prédominera.
8. This Limited Warranty is issued pursuant to, and in connection with, the Sales Terms, and, except to the extent, if any, that this Limited Warranty directly conflicts with the Sales Terms, this limited warranty is subject to all applicable provisions of the Sales Terms. In the case of a direct conflict, the provisions of this Limited Warranty shall control with respect to such Limited Warranty only.
WARRANTY RESPONSIBILITY
Date of Issuance: ______________________
Kingspan Insulated Panels
By:
Title:
726 Summerhill Dr., Deland, FL 32724, USA 386-626-6789 p 386-626-6887 f 2000 Morgan Rd., Modesto, CA 95358, USA 209-531-9091 p 209-531-9055 f
720 Marion Road (P.O. Box 07928) Columbus, OH 43207, USA 614-444-0110 p 614-444-7759 f 12557 Coleraine Dr., ON L7E 3B5, Canada 905-951-5600 p 905-951-3944 f
5202-272nd St., Langley, B.C. V4W 1S3, Canada 604-607-1101 p 604-607-1142 f www.kingspanpanels.us
Line 313 Section 074213 Installation Drawings Paragraph 1.5.1.1
Product Specification
| Profile: | Exterior: | Shadowline |
| Interior: | Shadowline |
| Embossing: | Exterior: | Stucco or non-embossed |
| Interior: | Stucco or non-embossed |
| Gauge: | Exterior: | 26, 24, 22 ga |
| Interior: | 26, 24, 22 ga |
Width: 24”, 30”, 36”, 42”
Thickness: 2”, 2.5”, 3”, 4”, 5”, 6”
Length: 8’ - 53’
| Reveal option: | Vertical: | 1/8” | |
| Horizontal: | 1/8” or 3/8” |
Orientation: Vertical or horizontal
| Post fabrication: | Trimless ends, folded corners |
| (Manufacturing limitations apply. Please contact us for detailed information) |
| R-value: | ≈ 7.2 per inch per ASTM C518 @ 75˚F |
| ≈ 8.25 per inch per ASTM C518 @ 35˚F |
Applications Shadowline high performance wall systems deliver an attractive and affordable panel choice. Shadowline panels, horizontally or vertically applied, use a patented double seal integrated joint. Standard reveals are 1/8” for vertical applications, and 3/8” for horizontal applications.
Shadowline panels are suitable for new and retrofit applications across the cold storage, commercial and industrial market sectors.
Design Features The foamed-in-place manufacturing process produces superior panels of consistent high quality that arrive to site ready for quick and easy installation, saving up to 50% in on-site construction time.
Panels are available with optional factory-caulked side joints to save erection labor (not available for cold storage applications).
Customer Options Kingspan offers a full spectrum of vibrant colors for every color scheme. The high performance coatings provide long-life protection, color and gloss retention. Custom color matching is available to meet individual building designs and creative freedom.
24” - 42”
Shadowline
Shadowline
Interior face
Exterior face
2” -6
KS Shadowline Data Sheet Insulated Wall Panel System
Kingspan’s single component systems can increase speed of build by up to 50%
Line 315 Section 074213 Product Data
Pat Szempruch Highlight
Pat Szempruch Highlight
Pat Szempruch Highlight
Pat Szempruch Highlight
Pat Szempruch Highlight
| Test | Procedure | Results |
| Fire | FM-4880 | Passed: Class 1 Fire Rating of Insulated Wall or Wall and Roof / Ceiling Panels, Interior |
| Finish Materials or Coatings, and Exterior Wall Systems |
ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN/ULC-S101 Fire Endurance Tests: 10 min and 15 min stayed in place
CAN/ULC-S102 Flame Spread: 5 / Smoke developed: 135 for panel with facings
CAN/ULC-S127 Flame Spread: <500 for foam core
| CAN/ULC S138 | Passed: Fire growth of foamed plastic insulated building panels in a full scale room |
| configuration |
CAN/ULC-S134 Passed: Standard method of test for fire of exterior wall assemblies
NFPA 259 Tested for potential heat of building materials
| NFPA 268 | Passed: Standard test method for determining ignitability of exterior wall assemblies |
| using a radiant heat energy source |
| NFPA 285 | Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics |
| of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components |
Structural FM-4881 Passed: Class +110/-154 Zone H Class +100/-140 Zone HM – LM
ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal ASTM C518 Transmission
Air Infiltration ASTM E283 0.003 CFM/ft2 of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
| Fatigue | Cyclic test to positive and negative | The panels exceeded 2 million alternate cycles without failure or damage |
| wind loading to ± L/180 deflection |
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to 2 PSI at 212°F for 21/2 hours
Skin Delamination No skin delamination with direct pull off pressure up to 1188 psf
Performance Testing and Approvals Kingspan insulated panels meet specific building envelope performance criteria and requirements stipulated by US and Canadian building codes.
Panels are tested in accordance with UL, ULC, FM and ASTM approval standards, testing methods and procedures. Kingspan insulated panels are listed by FM Global and Warnock Hersey.
KS Shadowline Data Sheet Insulated Wall Panel System
Issue 4: 10/2019
Thermal Performance at 75˚ Thickness U-Factor R-Value
2 0.07 14.4
2.5 0.06 18.0 3 0.05 21.6 4 0.03 28.8 5 0.03 36.0 6 0.02 43.2
Thermal Performance at 35˚ Thickness U-Factor R-Value
2 0.06 16
2.5 0.05 20 3 0.04 24 4 0.03 32 5 0.03 40 6 0.02 48
Kingspan North America DeLand, FL: 386-626-6789 Modesto, CA: 209-531-9091 www.kingspanpanels.us
Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading.
Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof.
Caledon, ON: 905-951-5600 Langley, BC: 604-607-1101 www.kingspanpanels.ca
For the product offering in other markets please contact your local sales representative or visit www.kingspanpanels.com
Pat Szempruch Highlight
Pat Szempruch
Fluropon Low-Gloss A low gloss finish is a unique exterior finish that gives your building a distinctively matte appearance.
Fluropon Low-Sheen A low sheen coating gives you a flat or “satin” finish. This two-coat system will make your project stand out.
Fluropon Premiere Need to make a statement with bold and bright colors? This three-coat system is designed to bring out depth and beauty of bright pigments with a clear coat for added protection.
Fluropon Solar-Reflective (SR) Fluropon SR contains solar-reflective pigments, offering durability that resists heat absorption and aids in structure cooling. We have thousands of SR’s energy efficiency coatings that meet ENERGY STAR®, LEED® and CRRC performance requirements.
Fluropon Effects Fluropon Effects transform the concept of color with innovative new palettes that have never before been achieved in 70% PVDF coating systems. These two- to three-coat systems create unique, mesmerizing effects. Kameleon creates an eye-catching color shift; Nova offers an intense sparkle; and Rustica features a nature-inspired color palette.
Fluropon Our flagship coating. Its excellent performance is a direct result of Sherwin-Williams' innovative technology—a two-coat fluoropolymer formulation that continually exceeds performance needs while maintaining its color and durability long into the future.
Fluropon Classic II When a sparkle appearance is desired, this two-coat fluoropolymer system utilizes mica-based pigmentation to deliver a subtle or bold metallic appearance without the need for a clear coat.
Fluropon Classic Take vibrancy to a new performance level with a special metallic effect color coat and a clear coat for added shine and protection, making this three-coat system gleam.
FLUROPON® 70% PVDF COATINGS
FROM SHERWIN-WILLIAMS
Sherwin-Williams® is chosen more often than any other brands of PVDF-based coatings. For PVDF exterior metal coatings systems, none is more trusted than our premium Fluropon coatings, which are fluoropolymer, containing 70% polyvinylidene difluoride (PVDF) resins. Field- and time- proven, they meet or exceed the most rigorous ASTM performance standards.
KEEP YOUR PROJECT LOOKING BEAUTIFUL
The long-lasting beauty of your project goes hand in hand with its durability.
FLUROPON® 70% PVDF
COIL COATING SYSTEMS
Mansfield ANG Building 403 - Mansfield, OH - KS Series
Line 316 Section 074213 Facyory Color Finish 2.2.1
Line 332 and 333 Section 074213 Coatings and caulking 2.2.1.2
FLUROPON®
TWO-COAT SYSTEM
Fluropon, Classic II, Low Gloss, Low Sheen and Solar Reflective (SR)
Topcoat
Pretreated Aluminum Backer
Primer
FLUROPON®
THREE-COAT SYSTEM
Classic and Premiere
Topcoat
Backer
Clear Coat
Pretreated Substrate Primer
Key Characteristics
Number of
Coats
Dry Film Thickness (DFT)
Total Topside
DFT:
Specular Gloss 60°
COATING
SYSTEM
Primer Top Coat
Clear Coat
Fluropon® Effects Coat
Backer +/-5 units of manufacturer's specification
FLUROPON® Solid Colors 2-Coat 0.2–0.3 mils
0.7-0.8 mils — 0.9-1.1 mils 0.3-0.4 mils 20-35
FLUROPON®
CLASSIC II
Metallic Utilizing Mica-Based
Pigmentation 2-Coat 0.2-0.3 mils 0.7-0.8 mils — 0.9-1.1 mils
0.3-0.4 mils 15-30
FLUROPON
CLASSIC
Metallic Utilizing Aluminum-Based
Pigmentation 3-Coat 0.2–0.3 mils 0.7-0.8 mils 0.4-0.5 mils 1.3-1.7 mils
0.3-0.4 mils 25-40
FLUROPON
PREMIERE
Bright, Vibrant Colors 3-Coat 0.2–0.3 mils 0.7-0.8 mils 0.4-0.5 mils 1.3-1.6 mils
0.3-0.4 mils 25-40
LOW-
GLOSS
Matte
Finish 2-Coat 0.2–0.3 mils 0.7-0.8 mils — 0.9-1.1 mils
0.3-0.4 mils 8-15
LOW-
SHEEN
Flat or "Satin" Finish 2-Coat 0.2–0.3 mils 0.7-0.8 mils — 0.9-1.1 mils
0.3-0.4 mils
10º maximum
SOLAR
REFLECTIVE
(SR)
Solar-reflective pigments 2-Coat 0.2–0.3 mils 0.7-0.8 mils — 0.9-1.1 mils
0.3-0.4 mils 20-35
FLUROPON®
EFFECTS
RUSTICA
Saturated Metallic
Color Collection
2-Coat 3-Coat
0.2-0.3 mils
0.7-0.8 mils
0.9-1.1 mils
0.3-0.4 mils 15-30
FLUROPON®
EFFECTS
NOVA
High-Intensity Sparkle 3-Coat 0.2-0.3 mils 0.7-0.8 mils 0.8-0.9 mils 1.7-2.1 mils
0.3-0.4 mils 40-60
FLUROPON®
EFFECTS
KAMELEON
Color-Shifting 3-Coat 0.2-0.3 mils
0.5-0.6 mils
0.8-0.9 mils
1.5-1.9 mils
0.3-0.4 mils 30-60
COMMITMENT TO QUALITY
Our coatings are trusted and field-proven through rigorous testing, providing key benefits to our customers.
Fluropon® is a registered trademark of The Sherwin-Williams Corporation. For details and health, safety and handling information, Material Safety Data Sheets (MSDS) are available at coil.sherwin.com.
Sherwin-Williams makes no warranties, expressed or implied, and disclaimers all implied warranties including warranties of merchantability or fitness for a particular use. Sherwin-Williams will not be liable for any special, incidental or consequential damages. © 2018 Sherwin-Williams. All Rights Reserved.
Mansfield ANG Building 403 - Mansfield, OH - KS Series coil.sherwin.com or call (866) 351-6900
SUBSTRATES
Fluropon coatings may be applied to a number of pretreated substrates including: Galvalume®, Hot-Dipped Galvanized (HDG) steel and aluminum.
END USES
All Fluropon coatings are ideal for external use on monumental, commercial, residential structures and pre-engineered buildings, including:
• Architectural and residential metal roofing systems
• Composite and insulated metal wall panel systems
BENEFITS
• Superior resistance to ultraviolet rays
• Outstanding color retention and consistency
• Excellent overall adhesion
• Great flexibility and formability
• High film integrity
COLORS
Our Fluropon systems are available in a wide range of colors, sheens, gloss levels and special effects to achieve nearly any look you can dream up.
FLUROPON® 70% PVDF
COIL COATING SYSTEMS
FLUROPON PERFORMANCE TESTING
Industry Specifications Compliance
AAMA1 2605-17A Requirements Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels
Substrates Pretreated substrates: Galvalume®, Hot-Dipped Galvanized (HDG) steel and Aluminum.
ASTM2 TEST METHOD AAMA 2605-17A REQUIRED TEST RESULTPHYSICAL TESTING
Falling Sand Abrasion ASTM D 968 65 ± 10 liters
Film Adhesion ASTM D 3359 No removal of film under tape in the cross-hatched area (Dry, Wet, Boiling Water)
Surface Burning Characteristics
ASTM E 84 Flame Spread Index: Class A. Smoke Developed Index: Class A
Graffiti Resistance ASTM D 6578/D 6578M Meets and exceeds
Humidity Resistance ASTM D 2247:
100% RH at 100° F for 1,000 hours
100% RH at 100° F for 2,000 hours 100% RH at 100° F for 3,000 hours
Kamelelon: Galvalume or HDG: Rating 8, no more than a few field blisters. Rustica:
No field blisters.
Galvalume or HDG: No field blisters Aluminum: No field blisters
Impact Resistance (Direct)
ASTM D 2794
Galvalume or HDG: 3x metal thickness inch-pounds, no loss of adhesion Aluminum: 1.5x metal thickness inch-pounds, no loss of adhesion.
Pencil Hardness ASTM D 3363 Fluropon®, Classic II, Low Gloss, Low Sheen, SR, Rustica: HB to 2H Premiere, Classic , Nova, Kameleon: HB to H
Salt Spray ASTM B 117:
1,000 Hours
3,000 Hours
Fluropon, Classic II, Premiere, Low Gloss, Low Sheen, SR, Rustica, Nova, Kameleon: Galvalume or HDG: Creep from scribe ≤ 1/16" (2mm), no field blisters.
Classic: Galvalume or HDG: Creep from scribe ≤ 1/32" (1mm), no blisters.
Fluropon, Classic II, Low Gloss, Low Sheen, SR, Rustica, Nova, Kameleon:
Aluminum: Creep from scribe ≤ 1/16" (2mm), no field blisters.
Premiere, Classic: Aluminum: Creep from scribe ≤ 1/32" (1mm), no blisters.
T-Bends ASTM D 41453 T-3T, no loss of adhesion
ASTM TEST METHOD AAMA 2605-17A REQUIRED TEST RESULT
SOUTH FLORIDA
EXPOSURE TESTING
Atmosperic Environmental Exposure Testing of Non- Metallic Materials
ASTM G7 45 degree southern exposure for panel racking
Color ASTM D 2244 No more than 5 Hunter units at 20 years.
Chalk ASTM D 4214 Rating no less than 8 at 20 years. Kameleon: Rating no less than 8 at 10 years.
Film Integrity ASTM G7 25 years
Erosion Resistance ASTM D 662 10% - 15%.
1American Architectural Manufacturers Association. 2American Society for Testing and Materials. 3Fluropon is not designed to bridge cracks in the substrate. Fluropon coatings will generally meet the requirements for most post-painted fabrication processes. However, variations in metal quality, thickness or cleaning/ pretreatment applications can lead to diminished flexibility.
Mansfield ANG Building 403 - Mansfield, OH - KS Series
Pat Szempruch Highlight
SW
-C
C- 2, 1- 9-
We’ll work with you to find a solution. Want a unique color? We’ll create it for you. Need a quick turnaround?
Talk to us, and we’ll help you get your project completed on time.
WE’RE HERE TO HELP
Give us a call and see how we can help with your next project.
coil.sherwin.com coilhelp@sherwin.com
(866) 306-2645
DO YOU HAVE A
UNIQUE APPLICATION?
FLUROPON® 70% PVDF
COIL COATING SYSTEMS
Non-Skinning Butyl Sealant
1. PRODUCT DESCRIPTION
Kingspan NS Butyl Sealant is a high solids, non-drying, self-healing synthetic rubber based sealant for u s e i n reducing sound and vapor transmission, standing roof seams, wall panels, insulated metal panel and metal building construction. Provides excellent adhesion to ZINCALUME®, KYNAR500®, stainless steel, polyvinylidene fluoride, Galvalume®, Galvalume® Plus, aluminum, concrete, gypsum, wood surfaces, foam boards, plastic and fiberglass. Kingspan NS Butyl Sealant is a VOC compliant, non-drying, non-bleeding formula which remains flexible to form a long lasting resilient seal. This non-webbing formulation exhibits excellent tackiness for permanent bonding. NS Butyl Sealant contains an anti-microbial agent which inhibits the growth of mildew and bacteria. FDA regulated for food contact. USDA and CFIA accepted.
Conforms to the following specifications:
• ASTM E2140-01 Standard Test Method for Water Penetration of Metal Roof Panels by Static Water
Pressure Head
• ASTM E1646-95 (2003) Standard Test Method for Water Penetration of Exterior Metal Roof Panel
Systems by Uniform Static Air Pressure Difference
• ASTM E1680-95 (2003) Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof
Panel Systems
• AAMA 800 flexibility cold testing of -100ºF
• AAMA 809 Specifications for Non-Drying Sealants
• Federal Specification TT-C-1796A for Caulking Compounds, Metal Seam, and Wood Seam (Type I)
2. RECCOMENDATIONS FOR USE
Surface Preparation:
For reliable, repeatable and durable results, adhesives and sealants must be applied to clean, dry, sound and frost free surfaces. For high strength bonds, surface contaminants such as paints, oils, oxide films, mold release agents, dirt, and the like, must be completely removed. Remove old sealants or adhesives.
Installation:
Kingspan NS Butyl Sealant can be applied from 10-oz (300ml) cartridges or 20-oz (600ml) sausages using standard caulking guns or pneumatic dispensers (air guns). 5-gallon pails or 50-gallon drums are available for bulk applications. Some applications may not be compatible with this product. Testing suitability for intended application before proceeding with full application is recommended.
Technical Data
Line 319 Section 074213 Sealants and Caulking 2.5.4.1
Clean-up:
Mineral spirits may be used.
3. TECHNICAL DATA:
Typical Properties
Color: White
Extrudability (ASTM D 2452): 40-60 sec. per 20 grams through a 0.104" orifice at 50 psi
Total Solids (ASTM C 681): 93.5 - 96.5%
VOC Content (via EPA Method 24) 3.47%
Volume Shrinkage (ASTM D 2453): Less than 10%
Weight per U.S. Gallon (ASTM D 1475): 12.90 – 13.14 lbs.
Coverage Range: 1500 lineal feet per gallon at 1/8” bead 695 lineal feet per gallon at 3/16” bead 392 lineal feet per gallon at ¼” bead
Drying Time: Non-skinning, remains permanently soft and tacky
Engageability: Sealant will engage easily to make a joint at 10ºF
Vehicle Bleedout (ASTM C772): No visible exudation of vehicle from sealant after three weeks at 158ºF (70ºC) on painted or unpainted metal surfaces
Flexibility (ASTM C 711): No loss of adhesion to -100ºF
Service Temperature Range: -100ºF to 200ºF (-70ºC to 90ºC)
Application Temperature Range: 10ºF to 120ºF (-10ºC to 50ºC)
Sag (ASTM D2202): Nil
Non-Corrosive: No darkening, etching or salt deposits on GALVALUME®, GALVALUME PLUS®, ACRYLUME®, ZINCALUME®, KYNAR 500®, aluminum, aluminized steel, or galvanized metal
Staining (ASTM D 925 Method A): Sealant will not stain a painted surface
Adhesion (ASTM C 794): Excellent adhesion to oily GALVALUME®, GALVALUME
PLUS®, ACRYLUME®, ZINCALUME®, KYNAR 500®,
aluminum, aluminized steel, or galvanized metal
Resistance to fungus/mildew growth: Will resist fungal attack and not support mildew growth
Heat aging: No loss of surface tack or adhesion
Weatherability (ASTM G 154): No cracking bleeding or loss of rubbery characteristics
Chemical Resistance: Excellent to water, ozone, water vapor, alcohols; fair to weak for acids and bases. Poor to organic solvents.
Static Water Pressure Head Test
(ASTM E-2140-01):
Sealant passes 6 inches of static water pressure head, no leakage.
Rate of Air Leakage Through Exterior Metal Roof Panel Systems (ASTM E 1680)
Sealant passes. Air infiltration @ 1.57 psf � 0.0016 cfm/ft^2 and 0.0032 cfm/lin.ft. Air infiltration @ 6.24 psf � 0.0037 cfm/ft^2 and 0.0073 cfm/lin.ft
Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference (ASTM E 1646):
Sealant passed. No water leakage.
Wet Flammability (ASTM D 56): 158 ºF flash point
Toxicity: Contains no carcinogenic ingredients. Dispose in accordance with local regulations. Meets FDA, USDA and
CFIA.
4. STORAGE LIFE
For maximum shelf-life, store unopened product between 32ºF and 90ºF. Shelf life is 18 months minimum in unopened containers.
5. PRECAUTIONARY INFORMATION
CAUTION: COMBUSTIBLE LIQUID & VAPOR. Contains mineral spirits. Keep away from heat and flame. Avoid skin contact. Wash thoroughly after handling. Avoid breathing vapor. Use with adequate ventilation. Do not take internally. See MSDS for additional information. Keep out of reach of children.
6. LIMITED WARRANTY
Any goods prove defective will be replaced or the purchase price refunded. The limited warranty described herein is in lieu of any other warranty, expressed or implied, including any implied warranty of merchantability or fitness for a particular use. The user shall determine suitability of the product for its intended use. Liability for any incidental or consequential damage or loss is excluded. The user assumes all risks of the product’s use, handling and storage.
MR150
TRANSLUCENT
MR101
BLUE WHITE
MR100
WHITE
MR105
ANTIQUE WHITE
MR3401
EGGSHELL
MR146
STONE
MR3461
ALMOND
MR191
SANDSTONE
MR3482
SAND
MR3404
WHEAT
MR3333
SIERRA TAN
MR3201
COPPERTONE
MR157
COPPER
MR184
TERRACOTTA
MR182
RED
MR180
BRANDYWINE
MR196
REGAL RED
MR171
REGAL BLUE
MR3801
PACIFIC BLUE
MR3510
WEATHERED ZINC
MR197
PATINA GREEN
MR3702
HEMLOCK GREEN
MR169
GREEN
MR168
HARTFORD GREEN
MR115
LIGHT GRAY
MR3514
GUTTER GRAY
MR4103
SILVER METALLIC
MR156
SILVER
MR118
SLATE GRAY
MR3421
CHAMPAGNE METALLIC
MR155
CHAMPAGNE
MR117
GUNMETAL GRAY
MR134
MEDIUM BRONZE
MR137
BROWN
MR131
CHOCOLATE BROWN
MR120
DARK BRONZE
MR121
LINCOLN BRONZE
MR126
CHARCOAL GRAY
MR194
EXTERIOR BRONZE
MR110
BLACK
Made in USA. Professional Grade.
Metal Roof Adhesive Sealant
• Neutral cure silicone
• Excellent adhesion
• Permanently flexible
• Extrudes to -20°F
• Adheres to:
- Metals
- Wood
- Masonry
- PVC/PVDF
- Common Construction Materials
• Also used as
- Gutter Sealant
- Chimney Flashing
- Snow Guard
- Pipe Boots
Visit novagard.com/color-match-product/metal-roof/ for our metal roof manufacturer color cross reference tool.
Section 319 Section 074213 Sealants and Caulking 2.5.4.1 Used where caulking is exposed https://www.novagard.com/novaflex/metal-roof-sealants/ http://novagard.com/color-match-product/metal-roof/
Effective Date: Aug 2020-v2.6
NovaFlex is proudly made in Cleveland, OH
Permanently Flexible
| • Will not shrink or crack | • Mold/Mildew resistant | |
| • Waterproof | • Superior UV resistance |
Interior and Exterior Applications
| • Excellent adhesion to most | • Will not sag or slump | |
| building substrates | • Tack-free in 10 minutes |
• Completely cured within 48 hours
Easily Gunned at all Temperatures
• Weatherproof plastic cartridges • Excellent tooling properties with removable tips
VOC Compliant in all 50 States (Green Building Compliant)
• Low odor • Solvent free
AAMA Verified for Window Installs
• Will not freeze • 18 month shelf life
• Available in all major siding, trim coil, window, and metal roof manufacturer colors
Professional Grade
Product Specifications
Typical Properties*
Metal Roof Adhesive Sealant
5109 Hamilton Avenue, Cleveland, OH 44114 USA
(216) 881-8111 | (800) 380-0138 | (216) 881-6977 F novagard.com
S I L I C O N E | H Y B R I D S | F O A M
ISO 9001:2015 QMS (with Design) , IATF 16949:2016 QMS (with Design) Certified Women’s Business Enterprise
Certified Woman Owned Small Business
Physical Property Test Method Performance Range Type I - Class 35
Performance Range Type II - Class 50
Appearance Paste (Various Colors) Paste (Various Colors)
Viscosity Brookfield #7 @ 10 rpm 3,500-7,000 poises 4,500-8,000 poises
Extrusion Rate 1/8" Orifice @ 50 psi 30 - 80 grams/minute 30 - 80 grams/minute
Skin Over Time 3/8" @ 50% RH & 77°F 5 - 10 minutes 5 - 10 minutes
Through Cure 3/8" @ 50% RH & 77°F 48 hours (14 days for OEM window applications)
48 hours (14 days for OEM window applications)
Physical Property Test Method Typical Value Type I - Class 35
Typical Value Type II - Class 50
Specific Gravity 1.00 - 1.05 1.15 - 1.25
Tensile Strength ASTM D412 140 - 200 psi 170 - 220 psi
Elongation ASTM D412 500 - 650% 800 - 1000%
Tear Resistance ASTM D624 30 - 35 pli 30 - 35 pli
Shore Hardness ASTM D2240 20 +/- 5 25 +/- 5
Service Temperature
- 40°F to 400°F (- 40°C to 204°C)
- 40°F to 400°F (- 40°C to 204°C)
Joint Sealant Designation ASTM C920
Type S Grade NS Class 35
Use NT, M, G, A, O
Type S Grade NS Class 50
Use NT, M, G, A, O
Adhesion Glass Aluminum Vinyl
ASTM D903 12 - 15 pli 10 - 14 pli 12 - 15 pli
12 - 15 pli 10 - 14 pli 12 - 15 pli
*The values outlined reflect testing that was conducted under laboratory conditions, actual results may vary. The information provided in the above table is not intended for use in preparing specifications. Please consult manufacturer for additional information.