ATTACHMENT 06_B403 Cyber_Drawings (Full size)_B3.pdf
PDF 36 MB Posted
- Attached to
- PBXP 222050 - B403 CYBER REPAIR
- Solicitation number
- W50S8R26RA005
About this file
This file contains architectural and engineering drawings for the B403 Cyber Repair project at Mansfield Lahm Air National Guard Base in Ohio. The drawings package includes comprehensive design documentation across civil, structural, architectural, mechanical, electrical, plumbing, fire protection, telecommunications, and security disciplines for a Type B-3 final repair project designated as PBXP222050.
The project scope encompasses renovation of an existing building to accommodate cyberoperations mission requirements in compliance with ICD-705 standards and DoD Building Code (UFC 1-200-01). Key design criteria include: Type II-B construction classification for Group B occupancy; automatic sprinkler fire protection systems per NFPA 13; fire alarm and mass notification systems per NFPA 72; life safety provisions for 123 occupants with two required exits; secured areas requiring contractor security compliance per specification 01 32 52; and cybersecurity controls per UFC 4-010-06. The project requires deferred design submittals for antiterrorism anchorage, rooftop fall protection systems, raised access floors, fire protection engineering services, direct digital controls design, and specialty inspections. Construction must be performed using U.S. companies and U.S. citizens per security requirements. The contractor is responsible for quality control program execution, building commissioning, sustainability certification through GBCI, and compliance with all erosion control and environmental requirements. Contract documents reference Monaco fire protection equipment and Advantor electronic security systems as sole-source vendors, with project completion required within 540 calendar days from notice to proceed.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
O H
IO
A
IR
N
AT
IO
N
AL
G U
AR
D
D R
A W
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
TA
SK
O R
D
ER
N O
G-001
C O
VE
R
S H
EE
T
M
AN
SF
IE
LD
L
AH
M
A
IR
N
AT
IO
N
AL
G
U
AR
D B
AS
E, O H
M
AN
SF
IE
LD
L
AH
M
A
IR
N
AT
IO
N
AL
G
U
AR
D B
AS
E, O H
JA
C
O
BS
G O
VE
R
N M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N S
R , S
TE
IR
VI
N
E, C
A
M . O
SS
AN
N A
K.
L
O N
BE
C
K
D . P
EA
R
SO
N
D . P
EA
R
SO
N
M
AY
PB
XP
FA
-2
1- D
-0
W
S8 R
F0
TYPE B-3 FINAL
R
EP
AI
R
B
FO
R C
YB
ER
FA
LOCATION MAP (NTS) VICINITY MAP
OHIO AIR NATIONAL GUARD
REPAIR B403 FOR CYBER
TYPE B-3 FINAL MAY 2026
PBXP222050
MANSFIELD LAHM AIR NATIONAL GUARD BASE, OH
PROJECT
BOUNDARY
PROJECT SITE
H
IO
A
IR
N
AT
IO
N
AL
G U
AR
D
D R
A W
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
TA
SK
O R
D
ER
N O
G-002
SH
EE
T
IN
D
EX
M
AN
SF
IE
LD
L
AH
M
A
IR
N
AT
IO
N
AL
G
U
AR
D B
AS
E, O H
M
AN
SF
IE
LD
L
AH
M
A
IR
N
AT
IO
N
AL
G
U
AR
D B
AS
E, O H
JA
C
O
BS
G O
VE
R
N M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N S
R , S
TE
IR
VI
N
E, C
A
M . O
SS
AN
N A
K.
L
O N
BE
C
K
D . P
EA
R
SO
N
D . P
EA
R
SO
N
M
AY
PB
XP
FA
-2
1- D
-0
W
S8 R
F0
TYPE B-3 FINAL
R
EP
AI
R
B
FO
R C
YB
ER
FA
SHEET INDEX
NO DRAWING INDEX
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
G-003 GENERAL SYMBOLS
GI001 LIFE SAFETY CODE ANALYSIS
GI002 LIFE SAFETY OVERALL FLOOR PLAN
GI103 CIVIL CODE COMPLIANCE SITE PLAN
CIVIL
C-001 CIVIL GENERAL NOTES, ABBREVIATIONS AND LEGEND
C-002 CIVIL OVERALL SITE ACCESS, STAGING AND HAUL ROUTE
CD101 CIVIL DEMOLITION AND EROSION CONTROL AND SEDIMENT CONTROL PLAN
C-101 CIVIL GRADING AND SITE LAYOUT PLAN
CU101 CIVIL UTILITY PLAN
C-501 CIVIL DETAILS 1
C-502 CIVIL DETAILS 2
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-002 STRUCTURAL ABBREVIATIONS
SD101 STRUCTURAL DEMOLITION FLOOR PLAN
SB101 STRUCTURAL FOUNDATION PLAN
SF101 STRUCTURAL CEILING FRAMING PLAN
SF102 STRUCTURAL ROOF FRAMING PLAN
S-501 STRUCTURAL DETAILS
S-502 STRUCTURAL DETAILS
S-510 STRUCTURAL CMU DETAILS
S-520 STRUCTURAL STEEL DETAILS
S-521 TYPICAL CEILING GRID DETAILS
ARCHITECTURAL
A-001 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS
A-002 ARCHITECTURAL ACCESSIBILITY STANDARDS
AD101 ARCHITECTURAL DEMOLITION FLOOR PLAN
AD102 ARCHITECTURAL DEMOLITION ROOF PLAN
AD201 ARCHITECTURAL DEMOLITION ELEVATIONS
A-101 ARCHITECTURAL FLOOR PLAN
A-102 ARCHITECTURAL ROOF PLAN
A-111 ARCHITECTURAL REFLECTED CEILING PLAN
A-201 ARCHITECTURAL BUILDING ELEVATIONS
A-310 ARCHITECTURAL BUILDING SECTIONS
A-401 ARCHITECTURAL WALL SECTIONS
A-450 ARCHITECTURAL ENLARGED PLANS AND ELEVATIONS
A-501 ARCHITECTURAL EXTERIOR DETAILS
A-502 ARCHITECTURAL CEILING DETAILS
A-503 ARCHITECTURAL WALL PENETRATION DETAILS
A-504 ARCHITECTURAL INTERIOR DETAILS
A-505 ARCHITECTURAL INTERIOR DETAILS
A-520 ARCHITECTURAL SECURE AREA NOTES AND DETAILS
A-521 ARCHITECTURAL INTERIOR RF DETAILS
A-522 ARCHITECTURAL SECURE AREA DETAILS
A-523 ARCHITECTURAL SECURE AREA DETAILS
A-524 ARCHITECTURAL SECURE AREA DETAILS
A-525 ARCHITECTURAL SECURE AREA DETAILS
A-526 ARCHITECTURAL SECURE AREA DETAILS
A-527 ARCHITECTURAL SECURE AREA DETAILS
A-601 ARCHITECTURAL DOOR SCHEDULE
A-701 ARCHITECTURAL WALL TYPES SCHEDULE
INTERIORS
I-001 INTERIORS GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
IN101 INTERIOR FINISH FLOOR PLAN
IN201 INTERIOR ELEVATIONS
IN202 INTERIOR ELEVATIONS
IN203 INTERIOR ELEVATIONS
IN204 INTERIOR ELEVATIONS
IN501 INTERIOR DETAILS
IN601 ROOM FINISH SCHEDULE AND FINISH LEGEND
IN701 INTERIOR MILLWORK SECTIONS
IN702 INTERIOR MILLWORK SECTIONS
IF101 INTERIORS FF&E PLAN
IF401 WORKSTATION TYPICALS
IF402 DESK TYPICALS
IG101 INTERIORS SIGNAGE PLAN
IG601 INTERIORS SIGNAGE SCHEDULE AND DETAILS
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES
FA101 FIRE ALARM OVERALL FLOOR PLAN
FA501 FIRE ALARM DETAILS
FA502 FIRE ALARM MATRIX
FIRE PROTECTION
FX001 FIRE SPRINKLER GENERAL NOTES
FX101 FIRE SPRINKLER OVERALL FLOOR PLAN
FX301 FIRE SPRINKLER SECTIONS
FX501 FIRE SPRINKLER DETAILS
PLUMBING
P-001 PLUMBING GENERAL NOTES AND ABBREVIATIONS
PD101 PLUMBING DEMOLITION GROUND FLOOR PLAN
P-101 PLUMBING UNDERGROUND FLOOR PLAN
P-102 PLUMBING OVERALL GROUND FLOOR PLAN
P-401 PLUMBING ENLARGED PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-602 PLUMBING SCHEDULES
P-701 ISOMETRIC - SANITARY SEWER
P-702 ISOMETRIC - DOMESTIC WATER
P-703 ISOMETRIC - STORM DRAIN PIPING
P-801 PLUMBING DOMESTIC COLD WATER SYSTEM ONE-LINE DIAGRAM
MECHANICAL
M-001 MECHANICAL LEGEND, ABBREVIATIONS, AND NOTES
M-002 MECHANICAL GENERAL NOTES
M-101 MECHANICAL DEMOLITION FLOOR PLAN
M-102 MECHANICAL FLOOR PLAN
M-103 UNDER FLOOR PLAN MECHANICAL
M-301 MECHANICAL SECTIONS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-607 MECHANICAL CONTROLS COVER
M-608 MECHANICAL CONTROLS
M-609 MECHANICAL CONTROLS
SHEET INDEX
NO DRAWING INDEX
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES & ABBREVIATIONS
E-002 ELECTRICAL LEGEND
ED101 ELECTRICAL SITE PLAN - DEMOLITION
ED102 ELECTRICAL POWER PLAN - DEMOLITION
ED103 ELECTRICAL LIGHTNING PROTECTION PLAN - DEMOLITION
ES101 ELECTRICAL SITE PLAN
EP101 ELECTRICAL POWER PLAN
EM101 ELECTRICAL POWER PLAN - MECHANICAL AND PLUMBING
EG101 ELECTRICAL GROUNDING PLAN
EG102 ELECTRICAL LIGHTNING PROTECTION PLAN
EL101 ELECTRICAL LIGHTING PLAN
E-401 ELECTRICAL ENLARGED PLAN
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL GROUNDING DETAILS
E-503 ELECTRICAL EQUIPMENT DETAILS
E-504 ELECTRICAL SECURITY DETAILS
ED601 ELECTRICAL ONE-LINE DIAGRAM - DEMOLITION
E-601 ELECTRICAL ONE-LINE DIAGRAM
E-610 ELECTRICAL EQUIPMENT CONNNECTION SCHEDULE
E-611 ELECTRICAL PANEL SCHEDULES
E-612 ELECTRICAL PANEL SCHEDULES
E-613 ELECTRICAL PANEL SCHEDULES
E-614 ELECTRICAL PANEL SCHEDULES
E-630 ELECTRICAL LIGHTING SCHEDULES
TELECOMMUNICATION
T-001 TELECOMMUNICATION LEGEND AND GENERAL NOTES
TS101 TELECOMMUNICATION SITE PLAN
TD101 TELECOMMUNICATION DEMOLITION FLOOR PLAN
T-101 TELECOMMUNICATION FLOOR PLAN
T-102 TELECOMMUNICATION CABLE TRAY PLAN
T-301 TELECOMMUNICATION CABINET ELEVATIONS
T-401 TELECOMMUNICATION ENLARGED PLANS
T-402 TELECOMMUNICATION ENLARGED PLANS
T-403 TELECOMMUNICATION ENLARGED PLANS
T-501 DETAILS
T-502 DETAILS
T-503 DETAILS
T-504 DETAILS
T-505 DETAILS
T-601 TELECOMMUNICATION SINGLE LINE DIAGRAMS
T-602 TELECOMMUNICATION SCHEDULES
SECURITY
TY001 SECURITY LEGEND AND GENERAL NOTES
TY101 SECURITY FLOOR PLAN
TY501 DETAILS
TY502 DETAILS
TY601 SINGLE LINE DIAGRAMS
AD101 SHEET SEQUENCE
SHEET TYPE
DISCIPLINE CHARACTER
SHEET
NUMBER
NORTH ARROW
GRID BUBBLES
VIEW NUMBER
(GRID INTERSECTION ON SHEET)
VIEW SCALE
VIEW
TITLE
VIEW TITLE
GRAPHIC
SCALE
INTERIOR ELEVATION REFERENCE
EXTERIOR ELEVATION REFERENCE
BUILDING SECTION NUMBER
ARROW & TAIL INDICATE
DIRECTION OF SECTION
FULL BUILDING SECTION
REFERENCE
WALL SECTION NUMBER
ARROW INDICATES
DIRECTION OF SECTION
WALL SECTION REFERENCE
DETAIL SECTION NUMBER
DETAIL CALLOUT REFERENCE
ROOM
TAG
EL: 8' - 0"
A
KEYNOTE
REVISION TAG
DOOR TAG
WINDOW /
LOUVER TAG
WALL/
STOREFRONT/
CURTAIN WALL
TAG
CEILING TAG
SPOT
ELEVATIONS
LEVEL HEADS LEVEL NAME
EL 0' - 0"
12" = 1'-0" 0 1" 2" 3"
MODIFIER CHARACTER
('-' IF NO MODIFIER NEEDED)
SECTION NUMBER
ARROW & TAIL INDICATE
DIRECTION OF SECTION
PARTIAL BUILDING SECTION
REFERENCE
SHEET ON WHICH SECTION
IS REFERENCED
SHEET ON WHICH SECTION
IS REFERENCED
SHEET ON WHICH SECTION IS
REFERNCED
SHEET ON WHICH SECTION
IS REFERNCED
X-XXX
X1
X1X1
X1
X RFI-0000
#X
X###X
REVISION NUMBER
RFI NUMBER
1' - 0" A.F.F.
Room Name
XXXXX ROOM NUMBER
AREA
(WHERE REQUIRED)
DESIGNATOR
(WHERE REQUIRED)
ROOM NUMBER
DOOR NUMBER
DESIGNATOR
(WHERE REQUIRED)
TYPE
EXPOSED CEILING
TAG
EXPOSED
MATCHLINE
/ A1011
MATCHLINE
REFERENCE
MATCHLINE
/ A1011
A1 View Name
SCALE 1/8" = 1'-0"
PROJECT
NORTH
TRUE
NORTH
X-XXX
X1
X1
X-XXX
X1
X-XXX
X1
X-XXX
X1
X-XXX
X1
X-XXX
PLAN
NORTH
SHEET ID
O H
IO
A
IR
N
AT
IO
N
AL
G U
AR
D
D R
A W
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
TA
SK
O R
D
ER
N O
G-003
M
AN
SF
IE
LD
L
AH
M
A
IR
N
AT
IO
N
AL
G
U
AR
D B
AS
E, O H
JA
C
O
BS
G O
VE
R
N M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N S
R , S
TE
IR
VI
N
E, C
A
R .S
M
IT
H
E.
N
EW
SU
M
D .P
EA
R
SO
N
S.
W
IN
ST
EA
D
M
AY
PB
XP
FA
-2
1- D
-0
W
S8 R
F0
TYPE B-3 FINAL
M
AN
SF
IE
LD
L
AH
M
A
IR
N
AT
IO
NA
L G
U
AR
D B
AS
E, H
R
EP
AI
R B
FO
R
C
YB
ER
FA
G
EN
ER
A
L N
O
TE
S
S
YM
B O
LS
SYMBOLS LEGEND SYMBOLS LEGEND
GENERAL PROJECT NOTES
1. BUILDING CODE
THE BUILDING CODE FOR THIS PROJECT IS THE DECEMBER 2024 EDITION OF UFC 1-200-01, DOD BUILDING
CODE.
2. SECURED AREAS
THIS PROJECT INCLUDES SECURED AREAS COMPLYING WITH ICD/ICS 705, UFC 4-010-05, AND ANGETL 25-01-02.
THE CONTRACTOR IS RESPONSIBLE FOR ALL SECURITY REQUIREMENTS OF SPECIFICATION 01 32 52 AND THE
CONSTRUCTION SECURITY PLAN (CSP). REQUIREMENTS INCLUDE BUT ARE NOT LIMITED TO:
• HANDLE AND PROTECT CONSTRUCTION PLANS AND ALL RELATED DOCUMENTS IN ACCORDANCE WITH THE
APPROVED CSP.
• INSTALL BARRIERS TO SEGREGATE CONSTRUCTION WORKERS FROM OPERATIONAL ACTIVITIES AND
VISUAL OBSERVATION OF UNAUTHORIZED AREAS IN ACCORDANCE WITH THE CSP.
• PROVIDE ACCESS AND ACCOMMODATION FOR PERIODIC SECURITY INSPECTIONS PERFORMED BY THE SITE
SECURITY MANAGER (SSM) OR THEIR DESIGNEE.
• PERFORM ALL CONSTRUCTION AND DESIGN WITH U.S. COMPANIES USING U.S. CITIZENS. U.S. COMPANIES USING INDIVIDUALS LAWFULLY ADMITTED FOR PERMANENT U.S. RESIDENCE ARE PERMITTED WITH APPROVAL
OF THE ACCREDITING OFFICIAL (AO) AND IN ACCORDANCE WITH THE APPROVED CSP.
• ALL WORKERS AND VEHICLES ARE SUBJECT TO IDENTITY VERIFICATION AND RANDOM SEARCHES BY
GOVERNMENT SECURITY PERSONNEL AT SITE ENTRY AND EXIT POINTS.
• PERFORM CORRECTIVE WORK AS NEEDED TO PASS SECURITY TESTS REQUIRED FOR ACCREDITATION OF
SECURED AREAS.
3. UNIFIED FACILITIES GUIDE SPECIFICATIONS
THIS PROJECT INCLUDES SPECIFICATIONS BASED ON THE UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS).
IN THE EVENT OF DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE CONTRACTING OFFICER WHO WILL MAKE A DETERMINATION IN ACCORDANCE WITH THE
FEDERAL ACQUISITION REGULATIONS (FAR).
4. SOLE SOURCE JUSTIFICATION AND APPROVAL
THE FOLLOWING SYSTEM VENDORS SHALL BE PROVIDED:
• FIRE PROTECTION EQUIPMENT AND CONTROLS: MONACO
• ELECTRONIC SECURITY SYSTEMS (ESS): ADVANTOR
5. SUBMITTALS
SUBMITTALS AND RESUBMITTALS SHALL BE NUMBERED USING THE SPECIFICATION SECTION ACCORDING TO
THE FOLLOWING EXAMPLE:
ORIGINAL SUBMITTAL: 051200-001
FIRST RESUBMITTAL: 051200-001.1
SECOND RESUBMITTAL: 051200-001.2
SUBMITTAL OF SIMILAR INFORMATION (FOR EXAMPLE WELDER CERTIFICATIONS) SHALL BE COMBINED INTO A
SINGLE SUBMITTAL TO REDUCE THE NUMBER OF SUBMITTALS THE GOVERNMENT MUST PROCESS.
6. SUSTAINABILITY
THIS PROJECT IS REGISTERED WITH GREEN BUILDING CERTIFICATION, INC (GBCI) AND WILL OBTAIN THIRD PARTY CERTIFICATION FOR SUSTAINABILITY. THE CONTRACTOR IS RESPONSIBLE FOR ALL CERTIFICATION COSTS, GBCI REVIEWS, AND SUBMITTAL OF ALL REQUIRED INFORMATION TO GBCI TO OBTAIN SUSTAINABILITY
CERTIFICATION. SEE SPECIFICATION 01 33 29 FOR ADDITIONAL INFORMATION.
7. QUALITY CONTROL PROGRAM
THE CONTRACTOR WILL EXECUTE A QUALITY CONTROL PROGRAM IN ACCORDANCE WITH SPECIFICATION 01 45
00. THIS INCLUDES:
• PREPARATION AND SUBMITTAL OF A QUALITY CONTROL PLAN FOR APPROVAL BY THE GOVERNMENT. THE GOVERNMENT MAY WITHDRAW APPROVAL OF THE PLAN AND REQUIRE A RESUBMITTAL IF THE PLAN DOES NOT
RESULT IN COMPLIANT WORK PRODUCTS AND WORKMANSHIP.
• APPOINTMENT OF A QUALITY CONTROL MANAGER (QCM), ALL REQUIRED QUALITY CONTROL SPECIALISTS, AND QUALIFIED TEST LABS. ALL APPOINTMENTS ARE SUBJECT TO APPROVAL BY THE GOVERNMENT.
• WEEKLY QC MEETINGS RUN BY THE QUALITY CONTROL MANAGER.
• EXECUTION OF THE THREE PHASES OF CONTROL INCLUDING THE PREPARATORY, INITIAL, AND FOLLOW-ON
PHASES.
8. QUALITY CONTROL INSPECTION AND TESTING
ALL QUALITY CONTROL TESTS AND INSPECTIONS REQUIRED BY THE SPECIFICATIONS AND DRAWINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE GOVERNMENT RESERVES THE RIGHT TO PERFORM THEIR OWN TESTING AND INSPECTIONS AT ANY TIME. GOVERNMENT TESTING AND INSPECTION ARE NOT A SUBSTITUTE
FOR THE CONTRACTOR'S QC REQUIREMENTS.
9. SPECIAL INSPECTION
THE CONTRACTOR SHALL PROVIDE AN INDEPENDENT SPECIAL INSPECTION AGENCY TO PERFORM THE SPECIAL INSPECTIONS AND TESTS REQUIRED BY SPECIFICATION 01 45 35. SPECIAL INSPECTIONS AND TESTS ARE IN ADDITION TO THE CONTRACTOR'S QUALITY CONTROL REQUIREMENTS. THE CONTRACTOR SHALL HIRE AND PAY FOR THE SERVICES OF THE SPECIAL INSPECTION AGENCY SUBJECT TO APPROVAL BY THE GOVERNMENT. THE SPECIAL INSPECTION AGENCY WILL REPORT TO THE COR AND SHALL SUBMIT REPORTS TO THE COR AND THE
QCM SIMULTANEOUSLY TO MAINTAIN INDEPENDENCE FROM THE CONTRACTOR.
10. BUILDING COMMISSIONING
THE CONTRACTOR SHALL HIRE A COMMISSIONING FIRM AND SPECIALIST (CxA) TO PERFORM THE
COMMISSIONING REQUIREMENTS OF SPECIFICATION 01 91 00.15.
11. DEFERRED DESIGN SUBMITTALS
THE CONTRACTOR SHALL HIRE AN ENGINEER REGISTERED IN THE STATE OF OHIO TO PREPARE THE DEFERRED DESIGN SUBMITTALS LISTED BELOW. DEFERRED DESIGN SUBMITTALS SHALL BE STAMPED BY THE PREPARING ENGINEER AND SHALL BE SUBMITTED FOR REVIEW BY THE DESIGNER OF RECORD, AND APPROVAL BY THE COR. THE CONTRACTOR SHALL IDENTIFY DEFERRED DESIGN ACTIVITIES IN THE
CONSTRUCTION SCHEDULE.
• ANTITERRORISM ANCHORAGE AND BRACING OF WALL MOUNTED OR SUSPENDED COMPONENTS
WEIGHING MORE THAN 31 LBS AND DISTRIBUTION LINES WEIGHING MORE THAN 10 PLF.
• ROOFTOP FALL PROTECTION SYSTEM.
• RAISED ACCESS FLOOR SYSTEMS.
12. FIRE PROTECTION DESIGN
THE CONTRACTOR SHALL HIRE A REGISTERED FIRE PROTECTION ENGINEER TO SERVE AS THE
QUALIFIED FIRE PROTECTION ENGINEER (QFPE) DURING CONSTRUCTION IN ACCORDANCE WITH UFC 3-600-01 FIRE PROTECTION ENGINEERING. THE QFPE SHALL APPROVE AND SEAL SHOP DRAWINGS, PERFORM INSPECTIONS, AND WITNESS ACCEPTANCE TESTING.
THE FIRE ALARM AND FIRE SPRINKLER DRAWINGS PROVIDE PERFORMANCE CRITERIA AND
CONCEPTUAL LAYOUTS. THE CONTRACTOR SHALL ENGAGE TECHNICIANS WITH THE FOLLOWING
MINIMUM QUALIFICATIONS TO PERFORM FINAL LAYOUT DESIGN AND PREPARE SHOP DRAWINGS:
• FIRE SPRINKLER: NICET LEVEL III CERTIFIED TECHNICIAN
• FIRE ALARM: REGISTERED FIRE PROTECTION ENGINEER OR NICET LEVEL IV CERTIFIED
TECHNICIAN.
THE QFPE SHALL REVIEW, APPROVE, AND SEAL THE SHOP DRAWINGS PRIOR TO SUBMITTAL TO THE
GOVERNMENT FOR FINAL REVIEW AND APPROVAL.
THE CONTRACTOR SHALL IDENTIFY FIRE PROTECTION DESIGN ACTIVITIES IN THE CONSTRUCTION
SCHEDULE.
13. DIRECT DIGITAL CONTROLS
THE CONTRACTOR SHALL HIRE A DIRECT DIGITAL CONTROLS CONTRACTOR TO DESIGN THE CONTROLS SYSTEM AND PREPARE DESIGN DRAWINGS IN ACCORDANCE WITH SPECIFICATION 23 09 00 FOR REVIEW
AND APPROVAL BY THE GOVERNMENT.
THE CONTRACTOR SHALL IDENTIFY CONTROL SYSTEM DESIGN ACTIVITIES IN THE CONSTRUCTION
SCHEDULE.
14. CYBER SECURITY
CONTROL SYSTEMS SHALL COMPLY WITH UFC 4-010-06 CYBERSECURITY OF FACILITY-RELATED
CONTROL SYSTEMS. SEE DIVISION 25 SPECIFICATIONS FOR CYBER SECURITY REQUIREMENTS FOR THE
FOLLOWING CONTROL SYSTEMS:
• FIRE ALARM CONTROLS
• ELECTRONIC SECURITY SYSTEMS (ESS)
• DIRECT DIGITAL CONTROL SYSTEM
15. DEMOLITION
DEMOLITION DRAWINGS ARE PREPARED BASED ON LIMITED SITE VISITS AND AS-BUILT DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO CONSTRUCT THE COMPLETE AND
OPERATIONAL FACILITY SHOWN IN THE DESIGN DOCUMENTS.
IBC SUMMARY
LIFE SAFETY CODE SUMMARY
APPLICABLE CODES AND STANDARDS
UFC 1-200-01 - DoD BUILDING CODE
UFC 3-600-01 - FIRE PROTECTION ENGINEERING FOR FACILITIES
UFC 4-010-01 - DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
UFC 4-021-01 - DESIGN AND O&M: MASS NOTIFICATION SYSTEMS
UFC 4-010-05 - SECURE AREA PLANNING, DESIGN, AND CONSTRUCTION
NFPA 1 - FIRE CODE
NFPA 10 - STANDARD FOR PORTABLE FIRE EXTINGUISHERS
NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
NFPA 24 - STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES
NFPA 70 - NATIONAL ELECTRICAL CODE
NFPA 72 - NATIONAL FIRE ALARM AND SIGNALING CODE
NFPA 80 - STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES
NFPA 90A - STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS
NFPA 101 - LIFE SAFETY CODE (LSC)
NFPA 110 - STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS
NFPA 170 - STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS
NFPA 220 - STANDARD ON TYPES OF BUILDING CONSTRUCTION
INTERNATIONAL BUILDING CODE (IBC)
TSFPEWG G 3-600-01.01-18
ANG ETL 24-01-03 FIRE PROTECTION DESIGN GUIDANCE
FIRE-RESISTANCE RATING REQUIREMENTS (TYPE II-B CONSTRUCTION)
PRIMARY STRUCTURAL FRAME
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS
WALLS
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
EXTERIOR NONBEARING WALLS - BASED ON FIRE SEPARATION DISTANCE = X
X > 10 FT
0 - HOUR
0 - HOUR
0 - HOUR
0 - HOUR
0 - HOUR
0 - HOUR
OCCUPANCY CLASSIFICATION
GROUP B (IBC)
NOTE: ALL STORAGE OCCUPANCIES IN BUILDING WILL BE CONSIDERED ACCESSORY (IBC 311.1.1)
TO THE MAIN OCCUPANCY AND, THEREFORE, CLASSIFIED AS GROUP B.
BUILDING CONSTRUCTION TYPE
TYPE II-B (IBC)
REQUIRED PROVIDED
0 - HOUR
0 - HOUR
0 - HOUR
0 - HOUR
0 - HOUR
0 - HOUR
REFERENCE
IBC SECTION 601
IBC SECTION 601
IBC SECTION 601
IBC SECTION 601
IBC SECTION 601
IBC TABLE 705.5
BUILDING HEIGHT AND AREA - (SPRINKLERED)
BUILDING AREA (SF)
BUILDING HEIGHT (NO. OF STORIES):
BUILDING HEIGHT (FT):
ALLOWABLE
92,000 (S1)
OCCUPANCY CLASSIFICATION
BUSINESS (NFPA 101)
CLASSIFICATION OF HAZARD OF CONTENTS
ORDINARY HAZARD CONTENTS
OCCUPANT LOAD FACTORS BASED ON USE
ASSEMBLY
BUSINESS
BUILDING EQUIPMENT SPACES
IT EQUIPMENT SPACES
CONCENTRATED BUSINESS
MEANS OF EGRESS CAPACITY
LEVEL COMPONENTS AND RAMPS
EXIT WIDTH
DOOR CLEAR WIDTH
OCCUPANT LOAD FACTOR (SF/OCC)
15 NET
150 GROSS
500 GROSS
300 GROSS
50 GROSS
CAPACITY FACTOR (IN/OCC)
0.2
MINIMUM REQUIRED CLEAR WIDTH
32 INCHES
REFERENCE
NFPA 101 6.1.11
MINIMUM NUMBER OF REQUIRED EXITS
NUMBER OF REQUIRED EXITS
*BASED ON CALCULATED OCCUPANT LOAD OF 123
ARRANGEMENT OF MEAN OF EGRESS FOR BUSINESS OCCUPANCY
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD-END CORRIDOR
FIRE RESISTANCE RATINGS REQUIREMENTS
TEF AND LABS
ELEC ROOM
REQUIRED
1 HOUR
1 HOUR OR SMOKE PARTITION
REFERENCE
TSFPEWG 3-600-01.01 -18 SECTION 3-2.1
NFPA 101 SECTION 8.7
ILLUMINATION OF MEANS OF EGRESS
ILLUMINATION OF THE MEANS OF EGRESS WILL BE PROVIDED WITHIN THE EXIT ACCESS AND EXIT DISCHARGE. THE EXIT ACCESS WILL INCLUDE ONLY CORRIDORS AND AISLES LEADING TO AN EXIT. THE EXIT DISCHARGE WILL INCLUDE AISLES, CORRIDORS, AND WALKWAYS LEADING TO A PUBLIC WAY
FLOORS AND WALKING SURFACES WITHIN AN EXIT AND WITHIN PORTIONS OF THE EXIT ACCESS AND EXIT DISCHARGE WILL BE ILLUMINATED AS FOLLOWS:
• FLOORS AND WALKING SURFACES (MEASURED AT THE FLOOR): 1 FT-CANDLE
FAILURE OF ANY SINGLE LIGHTING UNIT WILL NOT RESULT IN ILLUMINATION LEVEL OF LESS THAN 0.2 FT-CANDLE IN ANY DESIGNATED AREA.
REFERENCE
NFPA 101 SECTION 7.8.1.1.
NFPA 101 SECTION 7.8.1.3
NFPA 101 SECTION 7.8.1.4
EMERGENCY LIGHTING WITHIN THE MEANS OF EGRESS
EMERGENCY LIGHTING WITHIN THE MEANS OF EGRESS WILL BE PROVIDED WITHIN THE EXIT ACCESS AND EXIT DISCHARGE. THE EXIT ACCESS WILL INCLUDE ONLY CORRIDORS, AND AISLES LEADING TO AN EXIT. THE EXIT DISCHARGE WILL INCLUDE AISLES, CORRIDORS, AND WALKWAYS LEADING TO A PUBLIC WAY.
WHERE MAINTENANCE OF ILLUMINATION DEPENDS ON CHANGING FROM ONE ENERGY SOURCE TO ANOTHER, A DELAY OF NOT MORE THAN 10 SECONDS IS
PERMITTED.
EMERGENCY LIGHTING WILL BE PROVIDED FOR A MINIMUM OF 1-1/2 HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING
EMERGENCY LIGHTING WILL PROVIDE AN INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT, NOT LESS THAN .1 FT-
CANDLE, MEASURED ALONG THE MEANS OF EGRESS AT FLOOR LEVEL.
REFERENCE
NFPA 101 SECTION 7.9.1.2
NFPA 101 SECTION 7.9.1.3
NFPA 101 SECTION 7.9.2.1
NFPA 101 SECTION 7.9.2.1.1
MARKING OF THE MEANS OF EGRESS
EXITS WILL BE MARKED BY AN APPROVED EXIT SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT ACCESS, OTHER THAN MAIN EXTERIOR EXIT DOORS
THAT ARE CLEARLY IDENTIFIABLE AS EXITS.
EXIT SIGNS WILL BE PLACED SO THAT NO POINT IN AN EXIT ACCESS CORRIDOR IS IN EXCESS OF 100 FT OR THE RATED VIEWING DISTANCE OF THE SIGN
REFERENCE
NFPA 101 SECTION 7.10.1.2.1
NFPA 101 SECTION 7.10.1.5.2
MEANS OF EGRESS COMPONENTS
LOCKS, LATCHES, AND ALARM DEVICES
DOORS WILL BE READILY OPEN FROM THE EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED
LOCKS WILL NOT REQUIRE THE USE OF A KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE EGRESS SIDE
LATCHES WILL BE PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS METHOD OF OPERATION AND READILY OPERATED UNDER ALL LIGHTING
CONDITIONS
DOORS MUST SWING IN THE DIRECTION OF EGRESS TRAVEL FOR OCCUPANT LOADS GREATER THAN 50.
REFERENCE
NFPA 101 TABLE 7.2.1.5.1
NFPA 101 TABLE 7.2.1.5.3
NFPA 101 TABLE 7.2.1.5.10
NFPA 101 SECTION 7.2.1.4.2
MINIMUM REQUIRED INTERIOR FINISH OCCUPANCY
BUSINESS
REFERENCE
NFPA 101 A.10.2.2
PROVIDED
CLASS A, B, AND C
REQUIRED IN EXIT ACCESS CORRIDORS
CLASS C
REQUIRED IN OTHER SPACE
CLASS C
SYSTEMS:
WET PIPE SYSTEM DESIGNED IN ACCORDANCE WITH UFC 3-600-01 & NFPA 13.
FIRE ALARM/MASS NOTIFICATION SYSTEM DESIGNED IN ACCORDANCE WITH UFC 3-600-01, TSFPEWG G 3-600-01.01-18, UFC 4-021-01, AND NFPA 72.
ACTUAL
5,850
REFERENCE
IBC TABLE 506.2
IBC TABLE 504.4
IBC TABLE 504.3
REFERENCE
IBC SECTION 304
REFERENCE
IBC SECTION 602
REFERENCE
NFPA 101 TABLE 7.3.1.2
NFPA 101 TABLE 7.3.1.2
UFC 3-600-01 TABLE 10-1
UFC 3-600-01 TABLE 10-1
NFPA 101 TABLE 7.3.1.2
REFERENCE
NFPA 101 TABLE 7.3.3.1
REFERENCE
NFPA 101 SECTION 7.2.1.2.3.2.
PROVIDED CLEAR WIDTH
34 INCHES OR GREATER
REFERENCE
NFPA 101 7.4.1.1
INTERIOR FINISHES, IN ALL AREAS WHERE CLASS C IS REQUIRED, WILL HAVE A SMOKE DEVELOPMENT INDEX LESS THAN 450 AND A FLAME SPREAD INDEX LESS THAN 200 WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723, AS REQUIRED BY NFPA 101 SECTION 10.2.3.3.
SMOKE CONTROL
AUTOMATIC SMOKE EXHAUST IS REQUIRED FOR ELECTRONIC EQUIPMENT AREAS PER TSFPEWG 3-600-01.1-18 SECTION 2-13.
EDITION
CHANGE 4, 17 DECEMBER 2024
CHANGE 6, 06 MAY 2021
CHANGE 3, 24 MAY 2024
CHANGE 1, 01 JANUARY 2010
26 MAY 2023
CHANGE 1, 21 APRIL 2021
31 MARCH 2024
PROVIDED
1 HOUR
1 HOUR
APPLICABLE CODES AND STANDARDS
NOTES:
1. ALL STORAGE OCCUPANCIES IN BUILDING WILL BE CONSIDERED INCIDENTAL (NFPA 101 6.1.14.1.3) TO THE MAIN OCCUPANCY AND
THEREFORE, CLASSIFIED AS BUSINESS.
2. LABS SPACES ARE COMPUTER LABS AND WILL BE CLASSIFIED AS BUSINESS OCCUPANCIES.
REFERENCE
NFPA 101 6.2.2.3
REQUIRED
2*
PROVIDED
REFERENCE
NFPA 101 38.2.6.3
NFPA 101 38.2.5.2.1
NFPA 101 38.2.5.3.1
REQUIRED (FT)
PROVIDED (FT)
FEATURES OF FIRE PROTECTION
SYSTEM
AUTOMATIC SPRINKLER
FIRE PUMP
FIRE HYDRANTS
FIRE ALARM
MASS NOTIFICATION
FIRE EXTINGUISHER
STANDPIPE
SMOKE EXHAUST
REQUIRED?
YES
NO
YES
YES
YES
YES
NO
YES
PROVIDED?
YES
NO
YES
YES
YES
YES
NO
YES
GOVERNING CODE/STANDARD
NFPA 13 (2025) & UFC 3-600-01
N/A
NFPA 1 (2024) & UFC 3-600-01
NFPA 72 (2025) & UFC 3-600-01
NFPA 72 (2025), UFC 3-600-01, & UFC 4-021-01
NFPA 1, NFPA 101, & UFC 3-600-01
N/A
NFPA 92, UFC 3-600-01, & TSFPEWG G 3-600-01.01-18
BUILDING REHABILITATION (UFC 3-600-01 SECTION 34)
CATEGORY PER NFPA 101 CHAPTER 43
RECONSTRUCTION/CHANGE OF USE
REQUIREMENTS
AREA WILL COMPLY WITH REQUIREMENTS FOR NEW CONSTRUCTION PER NFPA 101 AND UFC 3-600-01
AS REQUIRED BY UFC 3-600-01 34-1.3.1
LABS AND TEF ROOM WILL HAVE INTERIOR FINISH RATINGS OF CLASS A OR B AND INTERIOR FLOOR FINISH RATINGS OF CLASS I OR II IN ACCORDANCE WITH TSFPEWG G 3-600-01.01-18 2-3.
SHEET ID
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
A N
G P
R O
J E
C T
N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
T A
S K
O R
D E
R N
O
GI001
L
IF
E S
A F
E T
Y C
O D
E A
N A
L Y
S
IS
M A
N S
F
IE
L D
L A
H M
A
IR
N A
T
IO
N A
L G
U A
R D
B A
S E
O
H M
A N
S F
IE
L
D L
A H
M A
IR
N
A T
IO
N
A L
G U
A R
D B
A S
E O
H
J A
C O
B S
G O
V E
R N
M E
N T
S E
R V
IC
E
S M
IC
H
E L S
O N
S R
S
T E
IR
V
IN
E
C
A
E P
IT
T
S
B M
IT
C
H E
L L
D P
E A
R S
O N
B B
U S
S
M A
Y
P B
X P
F A
-2
-D
-0
W S
R
F
TYPE B-3 FINAL
R E
P A
IR
B
F
O R
C Y
B E
R
F A
05-08-26
DN
4 2 1
A
B
C
D
LAB B
LAB C
LAB A
CIRCULATION
FIRE RISER
ELEC
OFFICE
OFFICE
OFFICE
SECURITY
VESTIBULE
CIRC
WOMENS
CONFERENCE
CONFERENCE
OPEN
OFFICE
BREAK
MENS
1 1
CP = 58'
T D
CP = 24'
TD = 122'
DE = 21'
0.2
0.2
0.2
0.2
CP = 65"
FE
FEFE
FE
FE
FE
FE
TEF
DIAGONAL DIMENSION OF SPACE
108' 0"
SEPARATION OF EXITS
37' 5"
CA
CA
CA
CA
DC
DC
DC
LIFE SAFETY LEGEND
INDICATES START OF CP & TD
INDICATES END OF CP
INDICATES POINT OF EXIT
146' TD 75' CP
1 HOUR FIRE RATED BARRIER
PATH OF EXIT TRAVEL WITH DISTANCES FROM SELECTED REMOTE LOCATIONS TO
NEAREST EXIT. INCLUDES; TOTAL TRAVEL DISTANCE (TD) AND COMMON PATH OF
TRAVEL(CP).
W
Z
X
Y
W = EGRESS CAPACITY FACTOR (IN/PERSON)
X = OCCUPANTS USING EXIT (PERSONS)
Y = EXIT CAPACITY (PERSONS)
Z = EXIT CLEAR WIDTH (IN)
OCCUPANCY CLASSIFICATION
LABEL OCCUPANCY/ USE
LOAD FACTOR
SF/PERSON
OCCUPANCY: BUSINESS
USE: ASSEMBLY
OCCUPANCY: BUSINESS
USE: CONCENTRATED BUSINESS
OCCUPANCY: BUSINESS
USE: BUSINESS
OCCUPANCY: BUSINESS
USE: IT EQUIPMENT SPACES
OCCUPANCY: BUSINESS
USE: BUILDING EQUIPMENT SPACES
XX
XX
XX
XX
XX
15 NET
50 GROSS
150 GROSS
300 GROSS
500 GROSS
CLEAN AGENT FIRE EXTINGUISHERFE
DRY CHEMICAL FIRE EXTINGUISHER
CA
DC
FE
A. REFER TO GL101 FOR GENERAL NOTES AND CODE ANALYSIS.
B. REFER TO EL101 FOR EXIT SIGNAGE.
OCCUPANT LOAD TABLE
ROOM
ID
ROOM NAME AREA
(SF)
OCCUPANT LOAD
FACTOR
OCCUPANT
LOAD
VESTIBULE
OPEN OFFICE
BREAK
OFFICE
OFFICE
OFFICE
TEF
LAB A
LAB B
LAB C
CIRCULATION
CIRC
WOMENS
MENS
CONFERENCE
CONFERENCE
SECURITY
FIRE RISER
ELEC
1:150
1:50
1:15
1:150
1:150
1:150
1:300
1:50
1:50
1:50
1:150
1:150
1:150
1:150
1:15
1:15
1:150
1:500
1:500
OCCUPANT LOAD TABLE 123
GENERAL SHEET NOTES
SHEET KEYNOTES
GRAPHIC SCALE(S)
PLAN
NORTH
SHEET ID
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
A N
G P
R O
J E
C T
N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
T A
S K
O R
D E
R N
O
GI002
L
IF
E S
A F
E T
Y O
V E
R A
L L
F L
O O
R P
L A
N
M A
N S
F
IE
L D
L A
H M
A
IR
N A
T
IO
N A
L G
U A
R D
B A
S E
O
H M
A N
S F
IE
L
D L
A H
M A
IR
N
A T
IO
N
A L
G U
A R
D B
A S
E O
H
J A
C O
B S
G O
V E
R N
M E
N T
S E
R V
IC
E
S M
IC
H
E L S
O N
S R
S
T E
IR
V
IN
E
C
A
E P
IT
T
S
B M
IT
C
H E
L L
D P
E A
R S
O N
B B
U S
S
M A
Y
P B
X P
F A
-2
-D
-0
W S
R
F
TYPE B-3 FINAL
R E
P A
IR
B
F
O R
C Y
B E
R
F A
04 8 16268
SCALE: 1/8"=1'-0"
SCALE 1/8" = 1'-0"
A1
LIFE SAFETY GROUND FLOOR PLAN
1 HORIZONTAL SLIDING DOOR ASSEMBLY PERMITTED FOR SPACES WITH
OCCUPANT LOADS LESS THAN 10 PER NFPA 101 SECTION 7.2.1.4.1(4)
2 1:12 RAMP SLOPE
W
W
W
W
W
W W
G
G
SHEET ID
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
GRAPHIC SCALE(S)
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
GI103
LI
FE
S A
FE
TY
C O
D E
C O
M
PL
IA
N
C E
SI
TE
P
LA
N
E.
P
IT
TS
J.
O
YE
I.
N
AT
H
1" = 20'
0 20' 40' 60'
SCALE:
A1 CODE COMPLIANCE SITE PLAN
SCALE: 1" = 20'
# SHEET KEYNOTES
1. NOT USED.
2. EXISTING FIRE WATER LINE.
3. EXISTING FIRE HYDRANT. ONLY ONE FIRE HYDRANT IS
REQUIRED FOR THIS FACILITY BECAUSE THE HYDRANT IS
WITHIN 150' OF FIRE DEPARTMENT CONNECTION, 350' OF
ALL EXTERIOR PORTIONS OF THE BUILDING AND IS
CAPABLE OF PROVIDING THE REQUIRED FIRE FLOW.
4. EXISTING 8" FIRE SERVICE LATERAL.
5. INTENDED FIRE DEPARTMENT MAIN ACCESS.
6. KNOX BOX LOCATION.
7. FIRE DEPARTMENT CONNECTION LOCATION.
8. ASSUMED LOT LINE.
9. EXISTING POST INDICATOR VALVE.
10. ALL PORTIONS OF BUILDING EXTERIORS ARE WITHIN 350'
OF HYDRANT.
11. FIRE DEPARTMENT ACCESS WITHIN 33' OF BUILDING
ENTRANCE.
12. TRANSFORMER USES LESS THAN 10,000 GALLONS OF LESS
FLAMMABLE LIQUID AND IS MORE THAN 5' FROM BUILDING
PER UFC 3-600-01 TABLE 4-4.
13. HYDRANT WAS USED AS FLOW HYDRANT DURING FLOW
TEST.
14. GAUGE HYDRANT IS ABOUT 200' EAST FROM FLOW
HYDRANT AND IS AT AN ELEVATION OF 2' ABOVE FINISHED
FLOOR.
15. GRAVEL AREA TO BE USED AS A FIRE DEPARTMENT
APPARATUS TURN AROUND AS APPROVED BY FIRE
DEPARTMENT.
16. GENERATOR IS AT LEAST 5' FROM BUILDING IN
ACCORDANCE WITH NFPA 37 4.1.4 REQUIREMENT FOR
GENERATORS AND NFPA 30 22.4 REQUIREMENT FOR FUEL
TANKS WITH EMERGENCY VENTING AND LESS THAN 30,000
GALLONS OF FUEL.
17. NO TURN AROUND IS REQUIRED FOR DEAD-END ACCESS
ROUTES LESS THAN 150' PER NFPA 1 SECTION 18.2.3.5.4.
6 7
3 14
PLAN
NORTH
D A
TE
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
C-001
C
IV
IL
G
EN
ER
A L
N O
TE
S, A B
B R
EV
IA
TI
O
N S
A N
D L
EG
EN
D
A.
T
H O
M
PS
O N
J.
O
YE
I.
N
AT
H
GRAVEL SURFACING
A. EXISTING SITE FEATURES, UTILITIES, AND BASE MAPPING SHOWN WERE OBTAINED FROM CAD FILES PROVIDED BY THE MANSFIELD-LAHM ANG. NO TOPOGRAPHIC SURVEY WAS PERFORMED. EXISTING CONDITIONS MAY VARY FROM THOSE SHOWN ON THESE PLANS. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND ADJUST WORK PLAN ACCORDINGLY PRIOR TO BEGINNING CONSTRUCTION.
B. MAINTAIN, RELOCATE OR REPLACE EXISTING MONUMENTS WHICH ARE DISTURBED OR DESTROYED DURING CONSTRUCTION. PERFORM THE WORK TO PRODUCE THE SAME LEVEL OF ACCURACY AS THE ORIGINAL MONUMENT(S) IN A TIMELY MANNER AND AT THE
CONTRACTOR'S EXPENSE.
C. EXISTING SITE FEATURES ARE SHOWN AS SCREENED LINES AND PROPOSED SITE FEATURES ARE SHOWN AS DARK LINES.
A. PROJECT TESTING: ALL TESTING REQUIRED WILL BE CONDUCTED BY THE CONTRACTOR, AS SPECIFIED.
B. ALL DISTURBED SURFACES SHALL BE REPLACED IN KIND. NO EXPOSED SOIL IS ALLOWED ON BASE.
C. CONTRACTOR TO FIELD VERIFY DEPTH AND LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION AND PROTECT ALL EXISTING UTILITIES NOT IDENTIFIED FOR REMOVAL DURING CONSTRUCTION. UTILITIES SHOWN ON THE DRAWINGS ARE BASED ON THE BEST AVAILABLE INFORMATION, AND MAY NOT REFLECT THE ACTUAL FIELD CONDITIONS OR LOCATIONS OF UNDERGROUND STRUCTURES OR EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE TO EXISTING UTILITIES.
D. THE CONTRACTOR TO NOTIFY MANSFIELD ANG FOURTEEN (14) FULL BUSINESS DAYS PRIOR TO PLANNED EXCAVATION, AND OBTAIN A DIG
PERMIT BEFORE BEGINNING WORK.
E. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES MARKED OR UNMARKED BEFORE COMMENCING CONSTRUCTION. THE CONTRACTOR TO USE EXTREME CARE IN ALL EXCAVATIONS TO AVOID CONFLICTS WITH ALL UTILITIES MARKED OR UNMARKED. THE CONTRACTOR AGREES TO PRESERVE ANY AND ALL UTILITIES AND STRUCTURES WITHIN TWO FEET OF FIELD MARKED UNDERGROUND
UTILITIES.
F. CONTRACTOR MUST NOTIFY THE COMMUNICATIONS SQUADRON PRIOR TO REMOVING ANY COMMUNICATIONS EQUIPMENT (FIBER OPTIC, COPPER CABLE, ETC.) OR IF ANY TYPE OF COMMUNICATIONS EQUIPMENT SHOULD NEED TO BE RELOCATED BECAUSE OF
CONSTRUCTION.
G. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE NORMAL OPERATING FUNCTIONS OF ALL UTILITY SYSTEMS THROUGH THE CONSTRUCTION SITE DURING THE ENTIRE DURATION OF THE PROJECT, TO THE EXTENT FEASIBLE. THE CONTRACTOR TO COORDINATE WITH CONTRACTING OFFICER REQUIREMENTS FOR SHUT DOWN AND DURATION LIMITS OF SHUT DOWN.
H. ELEVATIONS GIVEN ARE TO FINISHED GRADE UNLESS OTHERWISE NOTED.
I. SLOPE UNIFORMLY BETWEEN CONTOURS OR SPOT ELEVATIONS SHOWN.
APPROXIMATELY
AND
ARCHITECTURAL BARRIERS ACT
AGGREGATE BASE COURSE
ABANDON
ABANDONED
ASPHALT CONCRETE
AMERICANS WITH DISABILITIES ACT
AIR NATIONAL GUARD
APPROXIMATE
ANTI-TERRORISM
ANTI-TERRORISM OFFICER
AMERICAN WATER WORKS ASSOCIATION
ABA
ABC
ABN
ABND
AC
ADA
ANG
APPROX
AT
ATO
AWWA
L
LBS
LEV
LF
LOG
LP
LT
LENGTH
POUNDS
LOW EMISSION VEHICLE
LINEAR FEET
LIP OF GUTTER
LOW POINT
LEFT
BC
BLDG
BM
BMP
BOW
BUR
BACK OF CURB
BUILDING
BENCH MARK
BEST MANAGEMENT PRACTICE
BOTTOM OF WALL
BURIED
CB
CCSD
CI
CMP
C.O.
CO
CONC
CONST
COORD
COR
CL, C
CU YD
CATCH BASIN
CONVENTIONAL CONSTRUCTION STANDOFF DISTANCE
CAST IRON
CORRUGATED METAL PIPE
CONTRACTING OFFICER
CLEAN OUT
CONCRETE
CONSTRUCT
COORDINATE
CONTRACTING OFFICER'S REPRESENTATIVE
CENTERLINE
CUBIC YARD
DI
DIA, Ø
DEMO
DWG
DUCTILE IRON/DROP INLET
DIAMETER
DEMOLISH OR DEMOLITION
DRAWING
EAST, EASTING
ELBOW
ELECTRICAL
ELEVATION
EDGE OF SLAB/SIDEWALK
EDGE OF PAVEMENT
ENVIRONMENTAL PROTECTION AGENCY
EQUIPMENT
EROSION AND SEDIMENT CONTROL
EXISTING
E
ELB
ELECT
EL, ELEV
EOS
EP
EPA
EQUIP
ESC
EXST
F
FDC
FFE
FG
FH
FL
FOW
FT
FLANGE
FIRE DEPARTMENT CONNECTION
FINISHED FLOOR ELEVATION
FINISHED GRADE
FIRE HYDRANT
FLOWLINE
FACE OF WALL
FEET
G
GB
GOV
GAS
GRADE BREAK
GOVERNMENT OWNED VEHICLES
HC
HP
HEATING/COOLING
HIGH POINT
IE
INV
INVERT ELEVATION
INVERT
MAX
MH
MIN
MISC
MJ
MUTCD
MAXIMUM
MANHOLE
MINIMUM
MISCELLANEOUS
MECHANICAL JOINT
MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES
N
NTS
NOI
NPDES
NORTH, NORTHING
NOT TO SCALE
NOTICE OF INTENT
NATIONAL POLLUTANT DISCHARGE
ELIMINATION SYSTEM
OD
ODOT
OH,OVH
OSHA
OWS
OUTER DIAMETER
OHIO DEPARTMENT OF TRANSPORTATION
OVERHEAD
OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OIL/WATER SEPARATOR
PC
PCC
PCCP
PE
PED
PI
PJF
PSI
PT
PVC
PVI
PVT
PVMT
POINT OF CURVATURE
POINT OF COMPOUND CURVE
PORTLAND CEMENT CONC PAVEMENT
POLYETHYLENE
PEDESTRIAN
POST INDICATOR VALVE
PREMOLDED JOINT FILLER
POUNDS PER SQUARE INCH
POINT OF TANGENCY
POLYVINYL CHLORIDE OR POINT OF VERTICAL
CURVATURE
POINT OF VERTICAL INTERSECTION
POINT OF VERTICAL TANGENCY
PAVEMENT
R,RAD
RCP
REQ'D
RT
RADIUS
REINFORCED CONCRETE PIPE
REQUIRED
RIGHT
S, SS
SD
SIM
SOG
SPEC'D
SST
STA =
STND
STRUCT
SW
SWPPP
SANITARY SEWER
STANDARD DETAIL / STORM DRAIN
SIMILAR
SLAB ON GRADE
SPECIFIED
STAINLESS STEEL
STATION
STANDARD
STRUCTURAL
SIDEWALK
STORMWATER POLLUTION PREVENTION
PLAN
TBC
TG
TOC
TOS
TOW
TYP
TOP BACK OF CURB
TOP OF GRATE
TOP OF CONCRETE
TOP OF SLAB
TOP OF WALL
TYPICAL
UG
UNO
UST
UNDERGROUND
UNLESS NOTED OTHERWISE
UNDERGROUND STORAGE TANK
W W/
WATER
WITH
CIVIL GENERAL NOTES
CIVIL CONSTRUCTION NOTES
CIVIL SYMBOLS CIVIL ABBREVIATIONS
NEW
EXISTING
FIRE HYDRANT
VALVE
POST INDICATOR VALVE
SANITARY SEWER MANHOLE
PLUG
POST OR BOLLARD
TELECOM MANHOLE
ELECTRICAL TRANSFORMER
LIGHTNING PROTECTION
CLEANOUT
EDGE OF PAVEMENT
CURB
CURB AND GUTTER
POTABLE WATER LINE
NATURAL GAS LINEG
W
COMM TELECOMMUNICATION
BURIED ELECTRICALE-BUR
OHE OVERHEAD ELECTRICAL
STORM DRAIN LINESD
SS SANITARY SEWER LINE
F FIRE WATER LINE
SOD
CONCRETE
ASPHALT
OR STRUCTURE, BUILDING OR FACILITY
CENTER LINE, BUILDING, ROAD, ETC.
FLOW LINE
EDGE OF PAVEMENT
POST OR BOLLARD
ASPHALT
GRAVEL SURFACING
CONCRETE
SILT FENCE
CHAIN LINK FENCE
TELECOMMUNICATIONCOMM
E-BUR BURIED ELECTRICAL
INLET PROTECTION
DEMOLITION
DEMOLITION OF CONCRETE
DEMOLITION OF ASPHALT
DEMOLITION OF GRAVEL SURFACING
CONTRACTOR STAGING AREA
VERT VERTICAL
ABANDON PIPE
G NATURAL GAS LINE
A
A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
GRAPHIC SCALE(S)
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
C-002
C
IV
IL
O
VE
R
A
LL
S
IT
E A
C C
ES
S, S
TA
G
IN
G A
N D
H A
U L
R O
U
TE
A.
T
H O
M
PS
O N
J.
O
YE
I.
N
AT
H
GENERAL SHEET NOTES
1" = 200'-0"
0 200' 400' 600'
SCALE:
H
AR
R
IN
G
TO
N M
EM
O
R
IA
L R
O
AD
S AIRPORT ROAD
INTERNATIONAL DRIVE
CAIRNS ROAD
INTERNATIONAL
DRIVE N
INTERNATIONAL
DRIVE S
H
AR
R
IN
G
TO
N M
EM
O
R
IA
L R
O
AD
B414 B415
B412B410B525
B500
B403
B409
B601 B600
B602
B603
B522
B520
B420 B422
B421
B300
B416
B207
B203
B203A
B164
B407 B405
B108
B110
B112
B114
B104
B102
B120
T/W A
B408
A1 OVERALL SITE ACCESS, STAGING AND HAUL ROUTE
SCALE: 1" = 200'
PLAN
NORTH
MANSFIELD ANG
MAIN GATEPRIMARY HAUL
ROUTE
SECONDARY HAUL ROUTE, COORDINATE
ACCESS WITH CONTRACTING OFFICER
MANSFIELD ANG SECONDARY GATE,
COORDINATE ACCESS WITH CONTRACTING
OFFICER
PROPOSED CONTRACTOR
PARKING AREA, SEE NOTE A
PROPOSED CONTRACTOR
LAYDOWN AREA, SEE NOTE A
PROJECT
A. LAYDOWN AREA SHALL BE FOR STOCKPILES AND MATERIAL STORAGE.
PARKING AREA FOR CONTRACTOR'S EMPLOYEE PARKING AND TRAILERS. FINAL
LOCATION TO BE COORDINATED WITH CONTRACTING OFFICER. SUBMIT
STAGING PLAN INCLUDING TEMPORARY BARRIER LOCATION AND DETAIL FOR
APPROVAL PRIOR TO CONSTRUCTION.
B. ALL MATERIALS TO BE STOCKPILED FOR 24 HOURS OR MORE SHALL BE
COVERED UNLESS OTHERWISE DIRECTED OR APPROVED IN WRITING BY
CONTRACTING OFFICER.
C. COORDINATE ACCESS AND ESCORTING REQUIREMENTS TO THE SITE AND
FLIGHTLINE WITH CONTRACTING OFFICER PRIOR TO CONSTRUCTION.
D. CONTRACTOR TO RESTORE ALL STAGING AREAS TO EXISTING CONDITIONS AT
COMPLETION OF CONSTRUCTION ACTIVITIES.
E. RELOCATION OF THE FENCE AND ESTABLISHMENT OF THE
STAGING/LAYDOWN/PARKING AREA REQUIRES ACCESS TO THE AIRPORT
OPERATIONS AREA (AOA).
F. COORDINATE AOA TRAINING AND BADGING REQUIREMENTS WITH
CONTRACTING OFFICER.
G. COORDINATE FOREIGN OBJECT DEBRIS (FOD) MITIGATION PLAN WITH
CONTRACTING OFFICER PRIOR TO MOBILIZING. DEBRIS MUST BE KEPT FROM
ENTERING THE AIRCRAFT OPERATING AREA AT ALL TIMES.
H. CONTRACTOR SHALL NOT GO BEYOND BARRICADES AT ANY TIME WITHOUT
COORDINATION AND APPROVAL OF THE CONTRACTING OFFICER.
I. CONSTRUCTION ACTIVITY REQUIRES PRIOR FAA APPROVAL (FAA 7460-1),
WHICH WILL BE COORDINATED BY ANG. ACTIVITIES REQUIRING CRANES OR
OTHER LIFTING EQUIPMENT REQUIRE SPECIAL COORDINATION AND SEPARATE
APPROVAL THAN GENERAL CONSTRUCTION EQUIPMENT.
J. CONFIRM COMPLETION OF FAA APPROVAL PROCESS WITH CONTRACTING
OFFICER PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES, INCLUDING
MOBILIZATION ONTO THE AIRCRAFT APRON AND CREATION OF THE
STAGING/LAYDOWN/PARKING AREA.
K. CONTRACTOR PERSONNEL ARE STRICTLY PROHIBITED FROM CROSSING
OUTSIDE THE WORK AREA BOUNDARIES AS DEFINED ON THIS PLAN. CROSSING
THE BOUNDARY WITHOUT PERMISSION OF THE CONTRACTING OFFICER IS
CAUSE FOR IMMEDIATE AND PERMANENT DISMISSAL FROM THE SITE.
L. WHEN WORKING INSIDE THE AOA, THE CONTRACTOR SHALL MAINTAIN
CONTINUOUS TWO-WAY RADIO CONTACT WITH THE ATCT. THE CONTRACTOR
SHALL PROVIDE A MINIMUM OF THREE RADIOS CAPABLE OF TRANSMITTING
AND RECEIVING ON A VHF AIRCRAFT FREQUENCY FOR THIS PURPOSE. EACH
RADIO SHALL EITHER BE A HARD-WIRED VEHICLE-MOUNTED BASE RADIO OR A
PORTABLE TRANSCEIVER. IF PORTABLE RADIOS ARE USED, EACH MUST BE
EQUIPPED WITH A SPARE BATTERY PACK AND VEHICLE POWER.
M. THE CONTRACTOR IS RESPONSIBLE FOR GUARDING AGAINST UNAUTHORIZED
ACCESS TO THE SITE AND TO SECURE AREAS OF THE AIRFIELD, ANY OPENING
IN THE AIR OPERATIONS AREA (AOA) SECURITY FENCE SHALL BE GUARDED BY
AUTHORIZED (BADGED) PERSONNEL AT ALL TIMES WHILE OPEN. CONTRACTOR
IS REQUIRED TO MAINTAIN ACCESS TO THE PROJECT IN ACCORDANCE WITH
THE AIRPORT AND TSA REQUIREMENTS
N. VEHICLE ACCESS MUST BE MAINTAINED BETWEEN CONTRACTOR PARKING
AND LAYDOWN AREA FOR B102 CONSTRUCTION. COORDINATE WITH
CONTRACTING OFFICER PRIOR TO CONSTRUCTION.
1. CONSTRUCT AND TIE IN NEW FENCE PRIOR TO DEMOLISHING EXISTING
FENCE TO MAINTAIN CONTINUITY OF AOA SECURE PERIMETER.
COORDINATE INSPECTION OF NEW FENCING WITH CONTRACTING OFFICER.
SEE SHEETS CD101 AND CS101 FOR DETAILS
2. PLACE AT A MINIMUM LOW PROFILE BARRICADES MIN. 150' FROM TAXIWAY A
CENTERLINE. AREA BEYOND THESE BARRICADES IS AN ACTIVE AIRFIELD
OPERATIONS AREA
3. MANNED GATE, SEE GENERAL NOTE N
H
ER
C U
LE
S
W
AY
MUSTANG BLVD
SABRE RD
GALA
XY W
AY
SA
BR
E R
D
G
AL
AX
Y
W
AY
HERCULES WAY
HE
RC
UL
ES
W
AY
AIR
LIF
T LA
NE
H
ER
C U
LE
S
W
AY
180'-0"
SHEET KEYNOTES
PERIMETER
FENCE
FIRE
STATION
A
TE
S
L
Y
N
C
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
COMM
C O
M M
C O
M M
C O
M M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM COMM
COMM
COMM
COMM
COMM
COM
COMM
COMM
COMM
COMM
W
W
W
SS
SS
SS
SS
SS
SS
G
G
G
E-BUR
E-BUR
E-BUR
E-BUR
E-BUR
E-BU
R
E-BU
R
E-BU
R
COMM
COMM
COMM
COMM
M
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
E-BUR
E-BUR
C O
M M
C O
M M
C O
M M
COMM
COMM
COMM COMM
COMM
SS
SS
SS
SS
E-
BU
R E-
BU
R
E-
BU
R E-
BU
R
E-BUR
E-BUR E-BUR E-BUR E-BUR
W W
W
W
W
W
W
W
SS
G
G
G
G
SD
SD
SD
SD
W
W
W
W
W
W
SD
SD
SD
SD
SD
SHEET ID
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
GRAPHIC SCALE(S)
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
CD101
C
IV
IL
D
EM
O
LI
TI
O N
A N
D
ER
O
SI
O N
A N
D S
ED
IM
EN
T
C O
N
TR
O L
PL
A
N
A.
T
H O
M
PS
O N
J.
O
YE
I.
N
AT
H
1" = 10'
0 10' 20' 30'
SCALE:
A1 DEMOLITION AND EROSION AND SEDIMENT CONTROL PLAN
SCALE: 1" = 10'
B403
F.F. ELEV (1296.00
ON PRIOR DESIGN)
A. CONTRACTOR SHALL PROVIDE ALL NECESSARY EROSION CONTROL AS
FIELD CONDITIONS REQUIRE. CONTRACTOR IS RESPONSIBLE FOR
DEVELOPING AND SUBMITTING FINAL EROSION AND SEDIMENTATION
CONTROL (ESC) AND/OR SWPPP TO THE CONTRACTING OFFICE FOR
REVIEW AND APPROVAL AS SPECIFIED PRIOR TO CONSTRUCTION.
B. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL TEMPORARY AND
PERMANENT EROSION CONTROL MEASURES AT ALL TIMES. MAINTENANCE
OF TEMPORARY AND PERMANENT EROSION CONTROL MEASURES SHALL BE
CONSIDERED INCIDENTAL.
C. STORM WATER RUNOFF SHALL NOT BE ALLOWED TO LEAVE SITE
UNTREATED (LADEN WITH SUSPENDED SEDIMENT). IF THIS OCCURS THE
CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ANY PERMIT
VIOLATIONS AND FINES.
D. CONTRACTOR TO CONFORM TO OHIO EPA'S RAINWATER AND LAND
DEVELOPMENT MANUAL FOR ESC GUIDANCE, INCLUDED BEST
MANAGEMENT PRACTICES.
E. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR
RECONFIGURATION OF EXTERIOR DOWNSPOUT PIPING.
F. PRIOR EXCAVATION OCCURRED DURING CONSTRUCTION OF THE BUILDING
ADDITION. SIX TO SEVEN FEET OF UNCLASSIFIED FILL WAS EXCAVATED AND
REPLACED WITH NON FROST SUSCEPTIBLE FILL. IF IMPROVEMENTS EXIST
OUTSIDE OF THE PREVIOUS EXCAVATION LIMITS, OVER EXCAVATE FOUR
FEET AND REPLACE WITH NON FROST SUSCEPTIBLE FILL.
G. THE FIRE DEPARTMENT REQUIRES REQUIRES A 20 FOOT WIDE ASPHALT
DRIVE TO THE BUILDING. SAWCUT AND WIDEN THE ASPHALT BACK TO
NEAREST POINT EXISTING ROAD HAS 20' WIDTH (APPROXIMATELY 100 LF).
H. NEW FLIGHT LINE FENCE, SHOWN ON CS101, TO BE INSTALLED PRIOR TO
THE DEMOLITION OF FLIGHT LINE FENCE
1. SILT FENCE, SEE DETAIL A1/C-501
2. INLET PROTECTION, SEE DETAIL A6/C-501
3. SAWCUT AND DEMOLISH SIDEWALK, SEE GENERAL NOTE E
4. RETAIN AND PROTECT EXISTING UTILITIES
5. RETAIN AND PROTECT STORM DRAIN INLET AND UNDERGROUND PIPING
6. DEMOLISH EXISTING ABOVE GRADE GAS METER ASSEMBLY, SEE PD101
7. SAWCUT AND DEMOLISH EXISTING ASPHALT PAVEMENT
8. RETAIN AND PROTECT EXISTING UNDERGROUND INFILTRATION GALLERY
9. RETAIN AND PROTECT EXISTING SANITARY MANHOLE; REMOVE AND
SALVAGE FRAME AND LID
10. DEMOLISH GRAVEL SURFACING
11. DEMOLISH CHAIN LINK FENCE
12. RETAIN AND PROTECT LIGHTNING PROTECTION TEST WELLS, SEE ED101
13. DEMOLISH LIGHTNING PROTECTION TEST WELLS, SEE ED101
14. DEMOLISH BOLLARD
15. RETAIN AND PROTECT EXISTING CONCRETE PAVEMENT
16. RETAIN AND PROTECT SD CLEANOUTS
17. RETAIN AND PROTECT MANHOLE AND SURROUNDING CONCRETE PAD
18. REMOVE SD GRATE AND CAP; RETAIN AND PROTECT EXISTING SD PIPING
BELOW GRADE
19. DEMOLISH LAMBS TONGUE DRAIN
20. DEMOLISH HAND HOLE, SEE ED101
21. ABANDON BURIED ELECTRICAL IN PLACE, SEE ED101
22. DEMOLISH TRANSFORMER PAD, SEE ED101
23. SAWCUT AND DEMOLISH CONCRETE APRON
24. RETAIN AND PROTECT CHAIN LINK FENCE
25. CONSTRUCTION ENTRANCE, SEE DETAIL A8/C-501
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
B500
PLAN
NORTH
'-0
2'-0"
20'-0"
TYP 3
SEE NOTE F
X
XX20
SEE NOTE G
X X
X
GENERAL SHEET NOTES
# SHEET KEYNOTES
SEE GENERAL
NOTE H
A
TE
D N L
H
SHEET ID
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
GRAPHIC SCALE(S)
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
C-101
C
IV
IL
G
R A
D
IN
G A
N D
S
IT
E
LA
YO
U
T
PL
A N
A.
T
H O
M
PS
O N
J.
O
YE
I.
N
AT
H
GENERAL SHEET NOTES
# SHEET KEYNOTES
1" = 10'
0 10' 20' 30'
SCALE:
A1 GRADING AND SITE LAYOUT PLAN
B403
EXST FFE = 1296.00
RAISED FFE = 1297
33' UNOBSTRUCTED ZONE
33'
33' UNOBSTRUCTED SPACE
A. PROVIDE SMOOTH TRANSITION BETWEEN NEW AND EXISTING SIDEWALKS.
ALL SIDEWALK MUST BE ABA ACCESSIBLE.
B. SPOT GRADES SHOWN ARE APPROXIMATE, NO SURVEY WAS CONDUCTED.
ALL NEW WORK TO TIE INTO EXISTING ADJACENT GRADES.
C. ALL EQUIPMENT PADS TO BE A MINIMUM OF 4" ABOVE ADJACENT GRADE.
D. NEW SIDEWALKS AND ASPHALT PAVEMENT TO MATCH EXISTING
SURROUNDING GRADES. PROVIDE A SMOOTH TRANSITION ACROSS
CONNECTION POINTS.
E. SLOPE MECHANICAL YARD AND ATTACHED SIDEWALK TO BE A MINIMUM OF
1% CROSS SLOPE AWAY FROM THE BUILDING. CONTRACTOR TO VERIFY
EXISTING AND PROPOSED GRADES PRIOR TO CONSTRUCTION.
F. CONCRETE EQUIPMENT PAD IS LOCATED AND SIZED BASED ON EQUIPMENT
DEFINED ON ES101. IF EQUIPMENT SELECTED IS DIFFERENT IN SIZE, PAD
MAY NEED TO BE REVISED TO MATCH MANUFACTURER'S
RECOMMENDATIONS. REVIEW AND APPROVAL OF PAD LOCATION
REQUIRED. PAD SHOULD NOT CONFLICT WITH SIDEWALK CIRCULATION.
1. CONCRETE SIDEWALK, SEE DETAIL D8/C-501
2. CONCRETE EQUIPMENT PAD ON EXISTING CONCRETE APRON, SEE DETAIL
F1/S-501 AND NOTE C
3. ABA LANDING AND RAMP, SEE DETAILS D4/S-501 AND E4/A-501
4. EQUIPMENT ENCLOSURE, SEE DETAILS A3/A-450 AND A6/A-450
5. ASPHALT PATCHING PROVIDE SMOOTH TRANSITION BETWEEN EXISTING
AND PROPOSED PAVEMENT, SEE DETAILS A3 AND A7/C-502
6. BOLLARD, SEE DETAIL A4/C-501
7. MECHANICAL YARD CONCRETE, SEE DETAIL F4/S-501 AND SEE NOTE E
8. GRAVEL SURFACING, SEE DETAIL D4/C-501 AND E9/C-502
9. CHAIN LINK FENCE, SEE DETAIL C1/C-502
10. CONCRETE CONNECTION, SEE DETAIL A5/C-502
11. CONCRETE EQUIPMENT PAD, SEE DETAIL F4/S-501 AND SEE NOTE C
12. MATCH EXISTING GRADE, PROVIDE SMOOTH TRANSITION
13. CONCRETE TO ASPHALT TRANSITION, SEE DETAIL A1/C-502
14. SIDEWALK WILL BE ELEVATED ABOVE EXISTING ELEVATION OF ASPHALT,
CREATING A CURB. EXISTING ASPHALT GRADUALLY RISES TO MEET GRADE
OF SIDEWALK AT SOUTHEAST CORNER, SEE NOTE E
15. CONCRETE EQUIPMENT PAD ON NEW CONCRETE SIDEWALK, SEE DETAIL
F1/S-501 AND NOTE C AND F
16. PATCH CONCRETE APRON; MATCH EXISTING SUBBASE AND CONCRETE
DEPTH AND MATERIALS, SEE DETAIL A5/C-502
19'x4.8'
7.8'x5.3'
5'
5'
+1297
1:
+1297 1296
(MATCH
EXISTING)
1:12
+1297
1:
TYP 2
.0
0'
41.50'12.00'6.67'
5.
'-3
MATCH
EXISTING
5'
5'
5'
5'
5'
PLAN
NORTH
B500
5'
.0
0'
16'-1 1/2"
20.00'
21'-1/2"
21'-1/2"
10'
8'
7'-6 1/2" x 41'-9 3/4"
7.8'x5.3'
3'-4 1/2"
6' -9
/4
4'-6"
3'-0 1/4"
11'-1 1/2"
+ MATCH
EXISTING
1295.95+
1295.95+ 1295.75+
1295.75+ 1295.95+
1% MIN
1% MIN 1% MIN
TYP 2
1296(MATCHEXISTING)
5'
SEE NOTE F
MATCH EXISTING
6'
4'
2'
2'
4'- 1 3
/4"
3'
3'
5'
'-4
5' 5'
5'
5'-11"
5' -1
1"
0'-9"
'-4
/2
"15'-1"
16'
'-2
10'-3"
'-1
1"
5'
3'-7"
8' -5
9'-10"
1' -7
4'-3"
5'
8'-4"
3' -3
33'-9"
0' -6
2' -1
2' 2'
-7
2'-2"
4'
5'-5"
A
TE
K
E
E
Y
C
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
COMM
C O
M M
C O
M M
C O
M M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM COMM
COMM
COMM
COMM
M
COMM
COMM
COMM
COMM
COMM
COMM
W
W
W
SS
SS
SS
SS
SS
SS
SD
SD
SD
SD
SD
SD
G
G
G
E-BU
R
E-BU
R
E-BU
R
COMM
COMM
COMM
COMM
MM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
SD
E-BUR
SD
E-BUR
C O
M M
C O
M M
C O
M M
COMM
COMM
COMM COMM
COMM
SS
SS
SS
SS
E-
BU
R E-
BU
R
E-
BU
R E-
BU
R
SD
SD SD
W W
W
W
W
W
W
W
SS
G
G
G
G
SD
SD
SD
SD
W
W
W
W
W
W
SD
SD
SD
SD
SD
E-BUR
E-BUR
E-BUR
COMM COMM COMM COMM COMM COMM COMM COMM COMM
COMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM
SS
MMM
COMM
COMM
COMM
G
MM
G
W
SSS
COOWW
MMB
MMMM
SSSS
OMOCO
UR
MMMMMMMM
URURUR
SS
MM
EEEE
E MME-E-
GG
C
GGGG
B
G
BBBBB-B-BU-BBUBBU
CO
W
OMOM
C
U
COCOC
UUU
WW
S
CO
B MMB
MM
MMMMME
SS
CCO
E-BB
E
MMMM
RR
MM
E
WW
GG
WWWW
GGGGGGGG
R
E-E
RR
E BE BEE
MMMM
S
R
SSSSS
COC
RR
E-B E
B
EEEE
B
CCCCC
G G
G G
E-BUR
E-BUR
E-BUR
E-BUR E-BUR
SHEET ID
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
GRAPHIC SCALE(S)
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
CU101
C
IV
IL
U
TI
LI
TY
P
LA
N
A.
T
H O
M
PS
O N
J.
O
YE
I.
N
AT
H
GENERAL SHEET NOTES
# SHEET KEYNOTES
1" = 10'
0 10' 20' 30'
SCALE:
A1 UTILITY PLAN
EXST 6" SS
EXST 3"
GAS
EXST 8"
DOMESTIC & FIRE
EXST MH
EXST 6" SD
EXST CLEANOUT
EXST CLEANOUT
EXST FIRE HYDRANT
EXST UNIDERGROUND
INFILTRATION GALLERY
EXST 8" SD
EXST 4" SDEXST 4" SD
EXST 4" SD
B403
EXST (2) 4"
CONDUIT
EXST HH
EXST (2) 4"
CONDUIT
EXST HH
LIGHTNING
PROTECTION,
TYP 8
A. EXISTING UTILITY LOCAITONS AND ELEVATIONS ARE BASED ON AVAILABLE
RECORD DRAWINGS AND ARE SHOWN APPROXIMATELY. VERIFY EXACT
LOCATIONS AND ELEVATIONS. NOT ALL EXISTING UTILITIES MAY BE SHOWN.
B. SEE MECHANICAL SHEETS FOR EQUIPMENT AND EXTERIOR DUCT DETAILS.
C. SEE COMMUNICATIONS AND ELECTRICAL SITE PLANS FOR CONDUIT
ROUTING AND DETAILS.
1. ELECTRICAL SERVICE, SEE ES101
2. MECHANICAL EQUIPMENT, SEE M-102
3. FOLDING ANTENNAS TOWER LOCATION
4. GENERATOR, SEE ES101
5. RESET SSMH FRAME AND GRATE
6. TRANSFORMER, SEE ES101
7. COMM SERVICE, 4 - 4" CONDUITS, CONC ENCASED, SEE A1/T-505 AND T-401
FOR CONTINUATION
8. ELECTRICAL HANDHOLE, SEE ES101
9. 3/4" GAS LINE, SEE P-101 AND D1/C-501
10. CONDENSER UNITS, SEE M-102
11. AUTOMATIC AND MANUAL TRANSFER SWITCHES, SEE ES101
12. CT CABINET AND METER, SEE ES101
13. DOCKING STATION, SEE ES101
14. LOAD BANK, SEE ES101
15. COMM AND ELEC STUB UP FOR FUTURE CONNECTION TO ANTENNA TOWER
16. SEE P-101 AND P-102 FOR CONTINUATION OF ABOVE GRADE GAS, GAS
METER, AND CONNECTION TO HVAC EQUIPMENT
PLAN
NORTH
B500
EXST 4" SD
EXST WATER METER
VALVE VAULT
EXST FFE = 1296.00
RAISED FFE = 1297
TYP 5
10TYP 3
1 2
13 14
A
TE
B
A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H O
H
IO
A
IR
N A
TI
O
N A
L G
U A
R D
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
D . P
EA
R
SO
N
M
AY
PB
XP
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
AN
G
P R
O
JE
C T
N O
FA
-2
1- D
-0
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
R
EP
A
IR
B
FO
R C
YB
ER
FA
M A
R K
D
ES
C R
IP
TI
O N
M A
N
SF
IE
LD
L A
H M
A
IR
N A
TI
O
N A
L G
U A
R D
B A
SE
, O
H
TYPE B-3 FINAL
JA
C
O B
S G
O
VE
R N
M
EN
T
SE
R
VI
C
ES
M
IC
H
EL
SO
N
D R
ST
E
IR
VI
N
E, C
A
TA
SK
O R
D
ER
N O
W
S8
R
F0
C-501
C
IV
IL
D
ET
A
IL
S
A.
T
H O
M
PS
O N
J.
O
YE
I.
N
AT
HD1 TYPICAL TRENCH
SCALE: NTS
1. NEW SURFACING, OR SURFACE
RESTORATION, SEE SURFACE
RESTORATION DETAIL THIS
SHEET
2. TRENCH BACKFILL ABOVE PIPE
ZONE
3. PIPE OUTSIDE DIAMETER
4. PIPE BEDDING MATERIAL
5. NOT USED
6. DEPTH OF COVER
7. MARKING TAPE AS SPECIFIED
8. PIPE ZONE
9. MINIMUM WIDTH = PIPE OD + 1'-6"
NOTES
M
IN
6" M
IN
TY
P
NOTES:
PROVIDE MOUND FOR
SETTLEMENT UNLESS
OTHERWISE APPROVED
BY THE CONTRACTING
OFFICER
TOP SOIL INSTALLED AS
SPECIFIED, SEE NOTE B
SEE NOTE C
VERTICAL TRENCH
SHOWN, SEE NOTE A
A. SLOPE TRENCH WALLS OR SHORE EXCAVATIONS FOR CONSTRUCTION AND SAFETY
AND IN ACCORDANCE WITH CURRENT OSHA REQUIREMENTS.
B. THE TOP 6" OF TRENCH BACKFILL, BENEATH THE TOPSOIL LAYER, TO BE INSTALLED,
SMOOTHED, BUT LEFT UN-COMPACTED.
C. TOPSOIL AND SEEDING TO EXTEND BEYOND TOP OF TRENCH AND TO THE LIMITS OF
DISTURBANCE.
SOD/LANDSCAPING RESTORATION
D4 SURFACE RECONSTRUCTION
SCALE: NTS D8 TYPICAL CONCRETE SIDEWALK
SCALE: NTS
TRENCH BACKFILL
(SEE TRENCHING
DETAIL THIS SHEET)
NOTES:
SECTION
ELEVATION
A. BURY BOTTOM OF FILTER FABRIC 6" VERTICALLY BELOW FINISHED GRADE.
B. 2"x4" DOUGLAS FIR OR STEEL FENCE POSTS.
C. STITCHED LOOPS TO BE INSTALLED DOWNHILL SIDE OF SLOPE.
D. COMPACT ALL AREAS OF FILTER FABRIC TRENCH.
6' MAX SPACING
GEOTEXTILE
FABRIC
2"x2" BY 14 GA WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
JOINTS IN GEOTEXTILE FABRIC SHALL BE
SPLICED AT POSTS. USE STAPLES, WIRE
RINGS OR EQUIVALENT TO FABRIC TO POSTS
MINIMUM 4"X4" TRENCH
POST SPACING MAY BE INCREASED
TO 8' IF WIRE BACKING IS USED
2"x2" WOOD
POSTS, STEEL
FENCE POSTS, OR
EQUIVALENT
2"x2" BY 14 GA WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
MINIMUM 4"X4" TRENCH
2"x2" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT
" M
IN
2'
M
IN
A1 SILT FENCE
SCALE: NTS
3' -6
5'
1"
6" M
IN
36" DIA
FILL W/CONCRETE
AND ROUND OFF TOP
WITH GROUT PLUG
PAINT PER SPECS
12" SCH 40 STEEL PIPE,
GRIND SMOOTH ALL ROUGH
SURFACES AND EDGES
1" SLOPE
TOP OF FINISH GRADE
OR SURFACE MATERIAL
CONCRETE ENCASEMENT
A4 BOLLARD
SCALE: NTS A6 INLET PROTECTION
SCALE: NTS
1'-0" MIN
SUBGRADE OR
SUBGRADE COURSE
EXISTING GRAVEL
SURFACING
GRAVEL SURFACING
SEWN 6"
OVERLAP
#5 REBAR
GRATE
GEOTEXTILE INSERTFILTERED
WATER
#5 REBAR
SEWN 6"
OVERLAP
FLOWFLOW
NOTE:
A. FROST DEPTH 40", GAS TO BE BURIED AT A
MINIMUM 0F 40".
NOTES:
A. WOVEN GEOTEXTILE INSERT TO HAVE:
B. INSERT TO BE UV RESISTANT
C. INSERT TO…
This is the start of the file's text. The full file is on GovTribe.