UGM Simonka_AD2.1 DEMO FLOOR PLAN_12.19.24.pdf

PDF 170 KB Posted

Attached to
Union Gospel Mission - Construction Services at Simonka Place Women's Shelter
Solicitation number
S-C25102-00012036
Issued by
Marion County, Junction City, Oregon

About this file

This demolition floor plan drawing from Merrick Lentz Architect shows the planned demolition work for the Union Gospel Mission's Simonka Place facility renovation project in Keizer, Oregon. The drawing details extensive interior modifications including removal of existing walls, doors, fixtures, and finishes throughout the 22,181 square foot facility. Key demolition elements include removal of portions of exterior walls, concrete columns, interior non-bearing partition walls, doors and frames, exterior cladding, casework, wall coverings, and various bathroom fixtures.

The floor plan indicates multiple spaces being modified including dormitory rooms, offices, corridors, chapel areas, kitchen facilities, and common areas. Detailed demolition notes (D01-D16) specify requirements for structural shoring, utility modifications, and finish removal/replacement. The drawing is dated December 19, 2024 as part of an updated RFP set, with particular attention given to ADA compliance modifications in bathroom areas and careful preservation of certain utility rough-ins for future installations. The document serves as a key technical reference for contractors bidding on the renovation project, which must maintain facility operations during construction.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ACCESSIBLE

LEARNING CENTER

NLF LOUNGE

EXISTING

DORM

EXISTING

DORM

EXISTING

DORM

EXISTING

DORM

EXISTING

DORM

EXISTING

DORM

DORM

EXISTING

DORM

180A

HALL

180B

HALL

SHOWERS

STOR.

EXISTING

CASE MNGR

EXISTING

CASE MNGR

EXISTING

CASE MNGR

EXISTING

CASE MNGR

EXISTING

STOR.

EXISTING

STOR.

EXISTING

RECEPTION

EXISTING

LOBBY

EXISTING

IT

EXISTING

NLF OFFICE

EXISTING

NLF OFFICE

EXISTING

NLF OFFICEEXISTING

CLASSROOM

EXISTING

STAFF BREAKEXISTING

109A

STOR.

EXISTING

CORRIDOR

EXISTING

110C

CORRIDOR

EXISTING

CORRIDOR

EXISTING

141B

CHAPEL

EXISTING

VESTIBULE

101A

RECEPTION

NEW

HEALTH CONSULT

EXISTING

CORRIDOR

EXISTING

CORRIDOR

EXISTING

CORRIDOR

EXISTING

CORRIDOR

NEW

I.T.

EXISTING

141A

CHAPEL

EXISTING

R.R./SHOWERS

EXISTING

R.R./SHOWERS

EXISTING

PRAYER RM.

EXISTING

DAY ROOM

EXISTING

MEDS

EXISTING

CLINIC

NEW

OFFICE

EXISTING

OFFICE

EXISTING

WORKSHOP

EXISTING

MECHANICAL

EXISTING

STAFF

EXISTING

DINING ROOM

EXISTING

KITCHEN

EXISTING

PANTRY

EXISTING

RECEIVING

EXISTING

STORAGE

EXISTING

LAUNDRY

EXISTING

DRY STOR.

NEW

ADA DORM ROOM

EXISTING

DORM ROOM

EXISTING

DORM ROOM

EXISTING

DORM ROOM

EXISTING

DORM ROOM

EXISTING

DORM ROOM

EXISTING

STOR.

EXISTING

STOR.

EXISTING

STOR.

EXISTING

STOR.

EXISTING

STOR.

EXISTING

STORAGE

D10

D10D10

D10

D10

D10

D10

D10

D03 D03 D03 D04 D03D04D04D04 D04

D04 D04 D04

D04

D04

D04

D04

D04

ABV

D01D05

D05

D05

D05

D05D05D05

D05

D05

D05

D06

D06 D06

D06D06

D07

D07

D07

D07

D07D07

D07D07D07 D07D07

D07

D07

D07D07

D07

D07

D07

D07

D07

D05D05

D05

D10

D11

D12

D11

D12

D02

D02

D09

C

AD3.1

A

AD3.1

M

AD3.2

N

AD3.2

D

AD3.1

E

AD3.2

F

AD3.2

G

AD3.2

D

AD3.1

B

AD3.1

A

AD3.1

K

AD3.2

L

AD3.2

D13

D13

D05D06 D06D06

D16D15

D15

D14

D10

D10

D10

D10

D10

PORTION OF EXISTING EXTERIOR WALL TO BE

REMOVED. SHORE EXISTING STRUCTURE AS REQ'D.

DEMO EMBEDDED UTILITIES BACK TO POINT OF

CONNECTION.

EXISTING CONCRETE COLUMN TO BE REMOVED.

REMOVE COLUMN FOOTING

DEMO PORTION OF EXISTING EXTERIOR WALL FOR NEW

OPENING. REFER STRUCTURAL FOR NEW HEADER, KING

AND CRIPPLE STUDS. SHORE ROOF FRAMING AS REQ'D.

REMOVE EXISTING WINDOW AND FRAME. WINDOW

OPENING TO REMAIN.

(PORTION OF) INTERIOR NON-BEARING PARTITION WALL

TO BE REMOVED, TYP.; DEMO EMBEDDED UTILITIES

BACK TO POINT OF CONNECTION. RELOCATE

EMBEDDED UTILITIES TO REMAIN AS REQ'D. REPAIR

EXISTING CEILING AT REMOVED WALL. SHORE/UPGRADE

EXISTING CEILING FRAMING AS REQ'D AT DEMO'D WALLS

REMOVE PORTION OF EXISTING INTERIOR WALL FOR

NEW OR RELOCATED DOOR AND FRAME; RELOCATE

EMBEDDED UTILITIES AS REQ'D

REMOVE EXISTING DOOR AND FRAME

REMOVE EXTERIOR CLADDING AND SHEATHING AT

ADDITION, TYP.

PORTION OF EXISTING ROOF ABOVE TO BE REMOVED

REMOVE CARPETED WALLS AND BASE UP TO RUNNING

TRIM (±7'-0" A.F.F.; REPAIR GWB AS REQUIRED TO MAKE

SMOOTH, PRIME AND INSTALL NEW VINYL WALL

COVERING UP TO UNDERSIDE OF TRIM. INSTALL NEW

VINYL BASE. REPAINT ALL TRIM, DOOR FRAME, AND GWB

SURFACES IN HALL, INCLUDING CEILINGS.

REMOVE EXISTING VANITY CABINET, SINK AND FAUCET.

RETAIN ROUGH-IN'S AT LOCATIONS WHERE NEW

LAVATORY IS TO BE INSTALLED. CAP ROUGH-IN'S WITHIN

WALL WHERE NOT RE-USED. MODIFY ROUGH-IN'S AS

REQ'D FOR ADA-COMPLIANT INSTALLATION WHERE

REQUIRED.

REMOVE EXISTING NON-ACCESSIBLE TOILET. RETAIN

CLOSET FLANGE AT IF LOCATED 16"-18" FROM

ADJACENT SIDE WALL.

REMOVE EXISTING CASEWORK, TYP.

REMOVE BEADBOARD WAINSCOT, BASE TRIM AND PLATE

RAIL. REMOVE WALL COVERING ABOVE, FULL HT OF

WALL.

REMOVE WALL COVERING FULL HEIGHT OF WALL

REMOVE WALL COVERING ABOVE UP TO CEILING.

D01

D02

D03

D04

D05

D06

D07

D08

D09

D10

D11

D12

D13

D14

D15

D16 project name

12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com

UNPUBLISHED WORK

© 2024 MERRICK LENTZ ARCHITECT

Unauthorized use or reproduction of these drawings or any part herein without the permission of

Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title

MDL

design development

11/18/24 RFP SET

Simonka Place Union Gospel Mission

5119 River Road North Keizer, OR 97303

Addition and

Interior Alteration

12/19/24 UPDATED RFP SET

SCALE: 1/8" = 1'-0"

CONSTRUCTION FLOOR PLAN

DEMOLITION FLOOR PLAN NOTES

AD2.1

DEMOLITION

FLOOR PLAN

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .