UGM Simonka_A2.6 WALL SCHEDULES_12.19.24.pdf

PDF 132 KB Posted

Attached to
Union Gospel Mission - Construction Services at Simonka Place Women's Shelter
Solicitation number
S-C25102-00012036
Issued by
Marion County, Junction City, Oregon

About this file

This document is a detailed architectural wall schedule and details drawing for the Union Gospel Mission's Simonka Place renovation project in Keizer, Oregon. The drawing, dated December 19, 2024, includes specifications for both exterior and interior wall assemblies, providing comprehensive construction details for three types of exterior walls (W1, W2, W3) and five types of interior partition walls (P1-P5).

The technical specifications detail wall performance ratings, materials, and assembly requirements. The exterior walls feature various cladding options including manufactured stone and fiber reinforced cement (FRC) siding, with U-values ranging from 0.041 to 0.049. Interior partition walls are specified with fire resistance ratings of 1 hour (GA File #WP 3614 and WP 3647), incorporating sound attenuation batts, gypsum wall board (GWB), and specific framing requirements. The drawing includes detailed cross-sections showing precise measurements, materials, and installation requirements for each wall type, with particular attention to vapor barriers, insulation values, and weatherproofing details.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AT HORIZONTAL SIDING

INSTALL OVER P.T.

1/2"x3" @ 16" o.c. MAX.

VERTICAL FURRING OR

W/ ALTERNATE

PREMAN. FURRING

SUCH AS

VAPROBATTEN, OR EQ.

WALL FRAMING; 2x6 @ 16"o.c.

R-21 BATT INSUL EA.

JST SPACE

5/8" GWB AT INTERIOR

SIDE

INTERIOR SIDE

WALL PERFORMANCE:

U-0.0433 (R23.1)

5/8" DENS-GLASS

SHEATHING (TYPE "X")

MANUF'RD STONE

CLADDING PER ELEV.;

THIN SET PER MANUF'R

WEATHER BARRIER

TYPE W2

NEW EXTERIOR WALL WITH WOOD STUDS AND MANUF'RD STONE CLADDING

EX

TE

RI

OR

S

ID

E

VAPOR RETARDER*

4"

7MM DRAINAGE MAT

(STUC-O-FLEX WATERWAY

PLUS, OR EQ.)

*NOTE: PVA VAPOR

RETARDER COATING

MAY SUBSTITUTE FOR

SHEET VAPOR

RETARDER.

1/2" CONCRETE BOARD

EXTERIOR WALL ASSEMBLY

SCHEDULE NOTES

WALL FRAMING; 2x6 @ 16"o.c.

R-21 BATT INSUL EA.

JST SPACE

5/8" GWB AT INTERIOR

SIDE

INTERIOR SIDE

WALL PERFORMANCE:

U-0.041 (R24.59)

R0 .17

R5 .2/

3.0

R1 5.9

R0 .56

R0 .68

R0 .55

7/16" PLYWD SHEATHING

F.R.C. SIDING OVER

1/2"x3"@ 16" P.T.

PLYWD FURRING

WEATHER BARRIER (SA)

TYPE W1

NEW EXTERIOR WALL WITH WOOD STUDS AND F.R.C. SIDING

EX

TE

RI

OR

S

ID

E

VAPOR RETARDER*

8"

8" 65

8"

1/2" POLYISO RIGID INSUL.,

FOIL-FACED (R3)

R0 .18

*NOTE: PVA VAPOR

RETARDER COATING

MAY SUBSTITUTE FOR

SHEET VAPOR

RETARDER.

1x2 @ 24"o.c. F.R.C. VERT.

BATTEN, TYP.

PROVIDE ADD'L FURRING

@ BATTENS & PANEL

JOINTS

EXIST'G WALL FRAMING

EXISTING R-21 BATT

INSUL EA. JST SPACE

EXISTING 5/8" GWB AT

INTERIOR SIDE

INTERIOR SIDE

WALL PERFORMANCE:

U-0.049 (R20.4)

EXISTING SHEATHING

NEW F.R.C. SIDING OVER

NEW 1/2"x3"@ 16"o.c. P.T.

PLYWD FURRING

NEW WEATHER BARRIER

OVER EXIST'G SHTH'G

TYPE W3

EXISTING EXTERIOR WALL WITH NEW F.R.C. SIDING

EX

TE

RI

OR

S

ID

E

EXIST'G VAPOR

RETARDER*

8"

*NOTE: PVA VAPOR

RETARDER COATING

MAY SUBSTITUTE FOR

SHEET VAPOR

RETARDER.

NEW 1x2 @ 24"o.c. F.R.C.

VERT. BATTEN, TYP.

PROVIDE ADD'L FURRING

@ BATTENS & PANEL

JOINTS

1/2" POLYISO RIGID INSUL.,

FOIL-FACED (R3)

R0 .17

R3 .0

R1 5.9

R0 .56

R0 .68

R0 .56

R0 .13

R0 .26

R0 .17

R0 .79

R1 5.7

R0 .56

R0 .68

R0 .55

R0 .18

INTERIOR WALL ASSEMBLY

SCHEDULE NOTES

WALL FRAMING;

2x4@16"o.c.

SOUND ATTENUATION

BATT EA. JOIST SPACE

5/8" GWB AT INTERIOR

SIDE

5/8" TYPE "X" GWB

TYPE P1

INTERIOR PARTITION WALL

4"

- REFER 1/A2.X FOR TYP. PARTITION WALL

- SEE X/A2.X FOR RATED WALL INTERSECTIONS

TYPE "X" GWB NOT

REQ'D AT NON-

CORRIDOR

PARTITIONS

ASSEMBLY: GA FILE #

WP 3614 -

1 HOUR FIRE

RESISTANCE

AT WET WALLS USE

5/8" DENS ARMOR

PLUS IN LIEU OF GWB.

WALL FRAMING;

2x6@16"o.c.

MIN. 3-1/2" SOUND

ATTENUATION BATT EA.

JOIST SPACE

5/8" GWB AT INTERIOR

SIDE

5/8" TYPE "X" GWB

TYPE P2

INTERIOR PARTITION WALL

4"

- REFER 1/A2.X FOR TYP. PARTITION WALL

- SEE X/A2.X FOR RATED WALL INTERSECTIONS

TYPE "X" GWB NOT

REQ'D AT NON-

CORRIDOR

PARTITIONS

ASSEMBLY: GA FILE #

WP 3614 -

1 HOUR FIRE

RESISTANCE

AT WET WALLS USE

5/8" DENS ARMOR

PLUS IN LIEU OF GWB.

WALL FRAMING; 2x4@8"o.c.

STAGGERED ON 2x6

PLATES

SOUND ATTENUATION

BATT; FILL CAVITY

5/8" GWB AT INTERIOR

SIDE

5/8" TYPE "X" GWB

TYPE P3

INTERIOR PARTITION WALL

4"

- REFER 1/A2.X FOR TYP. PARTITION WALL

- SEE X/A2.X FOR RATED WALL INTERSECTIONS

TYPE "X" GWB NOT

REQ'D AT NON-

CORRIDOR

PARTITIONS

ASSEMBLY: GA FILE #

WP 3614 -

1 HOUR FIRE

RESISTANCE

AT WET WALLS USE

5/8" DENS ARMOR

PLUS IN LIEU OF GWB.

WALL FRAMING;

2x4@16"o.c.

SOUND ATTENUATION

BATT EA. JOIST SPACE

5/8" GWB AT INTERIOR

SIDE

5/8" TYPE "X" GWB

TYPE P4

INTERIOR PARTITION WALL

4"

- REFER 1/A2.X FOR TYP. PARTITION WALL

- SEE X/A2.X FOR RATED WALL INTERSECTIONS

ASSEMBLY: GA FILE #

WP 3647 -

1 HOUR FIRE

RESISTANCE

AT WET WALLS USE

5/8" DENS ARMOR

PLUS IN LIEU OF GWB.

EXISTING 1-HOUR

PARTITION TO REMAIN

(2x_@16"o.c. FRAMING W/

5/8" GWB EA. SIDE

NEW 5/8" GWB ONE SIDE

TYPE P5

INTERIOR PARTITION WALL

AT WET WALLS USE

5/8" DENS ARMOR

PLUS IN LIEU OF GWB.

HORIZ. RESILIENT

CHANNELS @ 24"o.c.

HORIZ. RESILIENT

CHANNELS @ 24"o.c.

WALL ASSEMBLY PER WALL

SCHEDULE.

FINISH: LEVEL 4 AT PAINT FINISHES,

LEVEL 2 ABOVE CEILING, HIDDEN

LOCATIONS AND BEHIND TILE/FRP,

LEVEL 3 BEHIND VINYL WALL

COVERINGS

2x_P.T. SILL PLATE, W/ POWER-

DRIVEN ANCHOR (.14M"Ø RAMSET,

1500 SERIES, 3/4" EMBEDMENT @

24"o.c., OR EQ.)

ROOF/CEILING ASSEMBLY ABV

(2) 2x_ STUD TOP PLATE, ACOUSTIC SEALANT EA. SIDE

TOP OF STRUCTURAL SLAB

FASTEN SHEAR WALL SHEATH'G

TO FACE OF STUD, WHERE

REQ'D; REFER STRUCT'L

2x4@48" o.c. DIAG. WALL BRACE

TO JOISTS ABV., W/ A34 EA. END,

ALT DIRECTION

ROOF FRAMING ABV

project name

12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com

UNPUBLISHED WORK

© 2024 MERRICK LENTZ ARCHITECT

Unauthorized use or reproduction of these drawings or any part herein without the permission of

Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title

MDL

design development

11/18/24 RFP SET

Simonka Place Union Gospel Mission

5119 River Road North Keizer, OR 97303

Addition and

Interior Alteration

12/19/24 UPDATED RFP SET

SCALE: 1/8" = 1'-0"

A2.6

DETAIL - TYP. INTERIOR PARTITION

A2.6

WALL

SCHEDULES

WALL DETAILS

SCHEDULES

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .