UGM Simonka_A2.1 FLOOR PLAN_12.19.24.pdf
PDF 459 KB Posted
- Solicitation number
- S-C25102-00012036
- Issued by
- Marion County, Junction City, Oregon
About this file
This is a construction floor plan drawing for the Simonka Place Union Gospel Mission renovation project in Keizer, Oregon, created by Merrick Lentz Architect. The drawing details a comprehensive facility layout featuring numerous dorm rooms, family dorms, offices, common areas, and support spaces within the 22,181 square foot facility. The plan shows both existing spaces and new construction, including a 523 square foot addition, with detailed annotations for wall types, room numbers, and dimensions. The drawing is dated December 19, 2024, and is labeled as an updated RFP set.
The floor plan includes specific construction notes and details for modifications to existing structures, new partition walls, window replacements, and ADA-compliant restroom upgrades. Key areas shown include case manager offices, family dorm rooms with private bathrooms, a chapel, child development areas, health consultation spaces, and various storage areas. The drawing provides technical specifications for contractors regarding wall removal, shoring requirements, utility modifications, and finish details. The plan demonstrates how the facility will maintain operations during construction through strategic placement of new and modified spaces.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ACCESSIBLE
LEARNING CENTER
NLF LOUNGE
EXISTING
DORM
EXISTING
DORM
EXISTING
DORM
EXISTING
DORM
EXISTING
DORM
EXISTING
DORM
DORM
EXISTING
DORM
180A
HALL
180B
HALL
SHOWERS
STOR.
EXISTING
STOR.
EXISTING
STOR.
NEW
CASE MNGR
EXISTING
LOBBY
EXISTING
NLF OFFICE
EXISTING
NLF OFFICE
EXISTING
NLF OFFICEEXISTING
CLASSROOM
EXISTING
STAFF BREAKEXISTING
109A
STOR.
EXISTING
CORRIDOR
EXISTING
CORRIDOR
NEW
FAMILY DORM
NEW
DIRECTOR OFFICE
EXISTING
141B
CHAPEL NEW
CHILD DEV.
EXISTING
VESTIBULE
NEW
CASE MNGR NEW
CASE MNGR
NEW
CASE MNGR
NEW
OFFICE
101A
RECEPTION
NEW
HEALTH CONSULT
EXISTING
CORRIDOR
EXISTING
CORRIDOR
EXISTING
CORRIDOR
EXISTING
CORRIDOR
NEW
I.T.
NEW
FAMILY DORM
NEW
FAMILY DORM
NEW
FAMILY DORM
NEW
FAMILY DORM
NEW
FAMILY DORM
NEW
FAMILY DORM
NEW
FAMILY DORM
NEW
124A
R.R.EXISTING
125A R.R.
EXISTING
126A R.R.
EXISTING
128A R.R.
EXISTING
129A R.R.
NEW
127A R.R.
NEW
130A R.R.
NEW
131A R.R.
EXISTING
141A
CHAPEL
EXISTING
R.R./SHOWERS
EXISTING
R.R./SHOWERS
EXISTING
PRAYER RM.
EXISTING
DAY ROOM
EXISTING
R.R.
EXISTING
R.R. EXISTING
MEDS
EXISTING
CLINIC
NEW
OFFICE
EXISTING
OFFICE
EXISTING
WORKSHOP
EXISTING
MECHANICAL
EXISTING
STAFF
EXISTING
R.R.
EXISTING
R.R.
EXISTING
DINING ROOM
EXISTING
KITCHEN
EXISTING
PANTRY
EXISTING
RECEIVING
EXISTING
STORAGE
EXISTING
LAUNDRY
EXISTING
DRY STOR.
NEW
ADA DORM ROOM
EXISTING
DORM ROOM
EXISTING
DORM ROOM
EXISTING
DORM ROOM
EXISTING
DORM ROOM
EXISTING
DORM ROOM
EXISTING
STOR.
EXISTING
STOR.
EXISTING
STOR.
EXISTING
STOR.
EXISTING
STOR. EXISTING
148A R.R.
EXISTING
146A
R.R.EXISTING
150A R.R.
EXISTING
152A R.R.
EXISTING
154A R.R.
EXISTING
156A R.R.
EXISTING
STORAGE
NEW
138A
CLASSROOM
1'-11" 2'-4" 1'-8"
3'-2" 2'-4" 1'-8"
8'-4"
5'- 9"
2'- 7"
4'- 9"3'-5"
5'-111 2"
1'- 7"
8'- 5"
6'-1"
9'- 0"
4'- 0"
1'-
4'-5"
5'- 0"
4'-101 2" 6'-01
2" 4'-11" 3'-9"
8'- 5"
EQ3EQ3EQ2EQ2EQ1EQ1
4'-6"4'-6"4'-5"
3'-
22'-0"
1'-0"4'-9"
±8 '-6
'-1 1 2"
9'- 61 2"
4'- 0"
2'-6"11'-5"
12'-1"
1'- 0"
2'-0"
2'- 0"
2'- 6"
5" 2'-
6" 3'-
81 2" 3'-
0" 5"
3'- 0"
1'- 4"
3'-11"
4'-91 2"
7'-11"
5'-0"
6'-2"
3'- 5"
7'-9"
3'-5"
2'- 0"
7'-11" 3'-10"
EQ
EQ
W1
W1
W2
P1 TYP.
P1TYP.
P1TYP.
P1P2
P1
TYP.
115 114 113 111
E100E100A
138A
138C
NEW
138B R.R.
138B
124A
125A126A
127A128A 129A129
126 125
130A
131A
E
E E
E
E
E
E
EE
E134
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
EE
E
E E
E
E
E
E146
E
E
E
E
EEE
EE
E E
E
EE
EE E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E E E E E
146A
E
E
AREA OF PROPOSED
ADDITION = 523 S.F.
ALIGN
P1
P1
P5A
P3 P3 P3 P5P5P5
P4
P4
P5
P5 P5
P4 P4
E E
E115E117E118E123E124E127E128E130E131EE
E
E
E
E
E E
E
129 126 125 114 113
100C
E
E
E156 E154 E152 E150 E148 E146
E159
E160
E169
±5'-111 2" 5'-0"
2013 ADDITION ORIGINAL BUILDING
A
DD
ITI
ON
OR
IG
IN
AL
B
UI
LD
IN
G
ALIGN
ALIGN
4'-0"
ALIGN
06A
TYP.
TYP.
07A
TYP.
06A
TYP.
07A
07A
07A
06A
06A
06A
10 10 10 1010
10 10 10
11 11 11 11 11
ABV.
C A3.1
07A
A A3.1
D A3.1
F A3.2
E A3.2
G A3.2
B A3.1
D A3.1
L A3.2
K A3.2
J A3.2
H A3.2
M A3.2
N A3.2
P A3.2
A A3.1
A A4.1
B A4.1
C A4.1
ALIGN
EXISTING CONDENSATE
FLOOR DRAIN
18 19
W3W3W3
WALL
TYPE W1WALL TYPE W3
WALL TYPE W3
WALL TYPE W3
W3 W3
W3
W3
W3
W3
PORTION OF EXISTING EXTERIOR WALL TO BE
REMOVED. SHORE EXISTING STRUCTURE AS REQ'D.
DEMO EMBEDDED UTILITIES BACK TO POINT OF
CONNECTION.
EXISTING CONCRETE COLUMN TO BE REMOVED
(PORTION OF) INTERIOR NON-BEARING PARTITION WALL
TO BE REMOVED, TYP.; DEMO EMBEDDED UTILITIES
BACK TO POINT OF CONNECTION. RELOCATE
EMBEDDED UTILITIES TO REMAIN AS REQ'D.
REMOVE EXTERIOR CLADDING AND SHEATHING AT
ADDITION, TYP.
NEW EXTERIOR WALL PER WALL SCHEDULE
NEW INTERIOR NON-BEARING PARTITION PER WALL
SCHEDULE. 1-HOUR RATED ASSEMBLY AT "A".
NEW INFILL PARTITION WALL AT EXISTING OPENING(S).
INFILL EXISTIGN CLERESTROY ABOVE WHERE
APPLICABLE; MATCH EXISTING WALL WIDTH, TYP.; TYPE
P-1, U.N.O.; 1-HOUR RATED ASSEMBLY AT "A".
NEW INFILL WALL AT EXISTING OPENING IN BEARING
WALL; 1-HOUR RATED ASSEMBLY
NEW MOVEABLE PARTITION WALL; MODERNFOLD
"ACOUSTI-SEAL PREMIER" PAIRED-PANEL
CONFIGURATION, MANUAL OPERATION, REFER
STRUCTURAL FOR NEW HEAD RAIL SUPPORT.
NEW EXTERIOR WINDOW PER SCHEDULE TO REPLACE
EXISTING IN EXISTING OPENING.
NEW EXTERIOR WINDOW PER SCHEDULE IN NEW
OPENING. REFER STRUCTURAL FOR NEW HEADER.
SHORE ROOF FRAMING AS REQ'D.
NEW ADA-COMPLIANT PRIVATE RESTROOM. PROVIDE
2x6 BLK'G IN WALL FOR LAVATORY AND GRAB BARS, PLUMBING BY DESIGN-BUILD.
NEW ADA-COMPLIANT PRIVATE CHILD RESTROOM.
PROVIDE 2x6 BLK'G IN WALL FOR LAVATORY AND GRAB
BARS, PLUMBING BY DESIGN-BUILD.
NEW PRIVATE RESTROOM. PLUMBING BY DESIGN-BUILD.
MODIFY EXISTING PRIVATE RESTROOM TO MAKE
ADA-COMPLIANT . PROVIDE 2x6 BLK'G IN WALL FOR
LAVATORY AND GRAB BARS, PLUMBING BY
DESIGN-BUILD.
REMOVE CARPETED WALLS AND BASE UP TO RUNNING
TRIM (±7'-0" A.F.F.; REPAIR GWB AS REQUIRED TO MAKE
SMOOTH, PRIME AND INSTALL NEW VINYL WALL
COVERING UP TO UNDERSIDE OF TRIM. INSTALL NEW
VINYL BASE. REPAINT ALL TRIM, DOOR FRAME, AND GWB
SURFACES IN HALL, INCLUDING CEILINGS.
REMOVE BEADBOARD WAINSCOT, BASE TRIM AND PLATE
RAIL. REMOVE WALL COVERING ABOVE, FULL HT OF
WALL.
REMOVE WALL COVERING FULL HEIGHT OF WALL
REMOVE WALL COVERING ABOVE UP TO CEILING.
project name
12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com
UNPUBLISHED WORK
© 2024 MERRICK LENTZ ARCHITECT
Unauthorized use or reproduction of these drawings or any part herein without the permission of
Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title
MDL
design development
11/18/24 RFP SET
Simonka Place Union Gospel Mission
5119 River Road North Keizer, OR 97303
Addition and
Interior Alteration
12/19/24 UPDATED RFP SET
SCALE: 1/8" = 1'-0"
CONSTRUCTION FLOOR PLAN
FLOOR PLAN NOTES
A2.1
CONSTRUCTION
FLOOR PLAN