This is an architectural elevation drawing sheet (A3.2) for the Union Gospel Mission's Simonka Place Women's Shelter renovation project in Keizer, Oregon, prepared by Merrick Lentz Architect. The drawing shows detailed exterior elevations from multiple angles including courtyard views (north, east, and west), entry views (north, west, and south), and loading area views (north and west). The sheet includes comprehensive notes detailing exterior finishing specifications, including new siding installations, window replacements, trim details, and various architectural elements.

The technical specifications call for 5/16" F.R.C. panel siding with 1x2 F.R.C. vertical battens at 24" O.C. over rainscreen furring and weather-resistant barrier, both for existing substrate overlays and new additions. Additional elements include manufactured stone cladding, multiple window replacements, various F.R.C. trim pieces, prefabricated metal flashings, aluminum screen walls, and new gutters and downspouts. The drawings indicate both existing elements to remain (such as composition roofing) and new construction components, with precise measurements and placement details provided at a scale of 1/8" = 1'-0".

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW SIDING OVER EXISTING SUBSTRATE, THUS: 5/16"

F.R.C. PANEL W/ 1x2 F.R.C. VERT BATTENS AT 24" O.C., OVER 1x4@16"o.c. RAINSCREEN FURRING, OVER NEW

W.R.B., OVER EXISTING PLYWOOD SHTH'G. REPLACE

EXISTING DAMAGED PLYWOOD SHTH'G WHERE REQ'D.

NEW SIDING AT NEW ADDITION, THUS: 5/16" F.R.C. PANEL

W/ 1x2 F.R.C. VERT BATTENS AT 24" O.C., OVER 1x4@16"o.c. RAINSCREEN FURRING, OVER W.R.B.

NEW 5/16" F.R.C. PANEL FASCIA OVER NEW W.R.B.

NEW VENEER MANUFACTURERED STONE CLADDING PER

SCHEDULE.

NEW WINDOW PER SCHEDULE W/IN EXISTING OPENING,

TO REPLACE EXISTING.

NEW WINDOW PER SCHEDULE IN NEW/MODIFIED

OPENING.

NEW CONT. 5/4 x 6 F.R.C. BASE TRIM W/ Z-FLASHING

OVER

NEW CONT. 1 x 3 F.R.C. RUNNING TRIM W/ Z-FLASHING

NEW CONT. 3/4" x 4 1/2" RUNNING TRIM W/ Z-FLASHING

NEW CONT. 1 x 4 F.R.C. RUNNING TRIM W/ Z-FLASHING

NEW 1 x 3 F.R.C. CORNER STANDING TRIM

NEW 1 x 3 F.R.C. CASING, TYP. ALL AROUND WINDOWS

NEW 5/4" x _ F.R.C. FASCIA

NEW PREFIN. METAL EDGE FLASHING; COLOR

INDICATED.

NEW COLUMN, REFER STRUCTURAL; W/ 5/16" F.R.C.

PANEL CLADDING EA. SIDE.

NEW ALUMINUM SCREEN WALL: 1.5"x4" ALUMINUM TUBE, POWDER COATED (COLOR TBD)

INFILL PORTION OF EXISTING WINDOW OPENING AS

REQ'D FOR NEW CLERESTORY WINDOW

NEW PREFIN. METAL FLASHING CAP

NEW 1 x 3 STANDING TRIM

NEW 1 x _ STANDING TRIM

NEW 5/4" x _ CONT. RUNNING EAVE TRIM

NEW PREFIN. METAL GABLE FLASHING

NEW PREFIN. METAL GUTTER; TO REPLACE EXISTING

WHERE APPLICABLE

NEW PREFIN. METAL DOWNSPOUT; TO REPLACE

EXISTING WHERE APPLICABLE. TIE INTO EXISTING

DRAINAGE SYSTEM CONNECTION POINTS

PAINT EXISTING CMU AND CONCRETE COLUMN, MATCH

PRIMARY BODY COLOR

EXISTING COMPOSITION

ROOFING TO REMAIN

P103

P10105 05 0507

24242424

EXISTING COMPOSITION

ROOFING TO REMAIN

P103

P101 07

08 11

EXISTING ROOF FASCIA

TO REMAIN

LINE OF EXISTING

BUILDING

PLATE

LINE

8'- 0"

EXISTING VERT. CHANNEL

SIDING TO REMAIN

9'- 9"

1'- 3"

'-0

3'-

0"

P101

P101

P101

P101 P103

P101

P101 project name

12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com

UNPUBLISHED WORK

© 2024 MERRICK LENTZ ARCHITECT

Unauthorized use or reproduction of these drawings or any part herein without the permission of

Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title

MDL

design development

11/18/24 RFP SET

Simonka Place Union Gospel Mission

5119 River Road North Keizer, OR 97303

Addition and

Interior Alteration

EXTERIOR ELEVATION NOTES

A3.2

EXTERIOR

ELEVATIONS

SCALE: 1/8" = 1'-0"

F

A3.2

EXTERIOR ELEVATION - COURTYARD NORTH

SCALE: 1/8" = 1'-0"

E

A3.2

EXTERIOR ELEVATION - COURTYARD EAST

SCALE: 1/8" = 1'-0"

G

A3.2

EXTERIOR ELEVATION - COURTYARD WEST

SCALE: 1/8" = 1'-0"

H

A3.2

EXT. ELEV. - ENTRY NORTH

SCALE: 1/8" = 1'-0"

J

A3.2

EXT. ELEV. - ENTRY WEST

SCALE: 1/8" = 1'-0"

K

A3.2

EXT. ELEV. - ENTRY SOUTH

SCALE: 1/8" = 1'-0"

L

A3.2

EXT. ELEV. - ENTRY SOUTH

SCALE: 1/8" = 1'-0"

M

A3.2

EXT. ELEV. - LOADING NORTH

SCALE: 1/8" = 1'-0"

N

A3.2

EXT. ELEV. - LOADING WEST

SCALE: 1/8" = 1'-0"

P

A3.2

EXT. ELEV. - LOADING NORTH

Sheets and Views
a3.2

File details come from the government source that posted it. Updated .