UGM Simonka_A1.1 SITE PLAN_12.19.24.pdf

PDF 626 KB Posted

Attached to
Union Gospel Mission - Construction Services at Simonka Place Women's Shelter
Solicitation number
S-C25102-00012036
Issued by
Marion County, Junction City, Oregon

About this file

This is a site plan drawing for the Union Gospel Mission's Simonka Place renovation project in Keizer, Oregon, prepared by Merrick Lentz Architect. The drawing details a 523 square foot proposed addition to an existing building, along with site improvements including new concrete sidewalks, ramps, landings, and lighting upgrades. The plan shows existing parking lots containing 32 total spaces (14 + 9 + 9), accessible parking areas, loading zones, landscaping, and courtyard areas. The site plan includes detailed notes for new construction elements including concrete work, lighting installations, and two add alternates for fencing improvements.

The site plan specifies two major add alternates: Add Alternate #1 involves demolishing existing perimeter fencing and installing new 8' chain link fence with PVC privacy slats on three sides, while Add Alternate #2 includes installing new 8' chain link fencing with a 15' wide motorized rolling gate equipped with RFID and keypad entry systems. Additional technical specifications include new directional arrows, signage, concrete curbing, and accessibility features such as detectable warning strips and ramps with 1:12 slopes. The drawing is dated December 19, 2024, marked as an "UPDATED RFP SET" for the project located at 5119 River Road North in Keizer, Oregon.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

'-0

SI

DE

YA

RD

SE

TB

AC

K

'-0

SI

DE

YA

RD

SE

TB

AC

K

EXISTING

BUILDING

EXISTING

LOADING AREA

EXISTING

PARKING LOT

EXISTING

PARKING LOT

EXISTING ACCESSIBLE

PARKING TO REMAIN

EXISTING 14

PARKING SPACES

EXISTING 9

PARKING SPACES

EXISTING 9

PARKING SPACES

EXISTING

LANDSCAPING

EXISTING

LANDSCAPING

EXISTING CONC.

CURB, TYP.

EXISTING

COURTYARD

PAVING TO

REMAIN

EXIST'G CHAIN LINK FENCE W/

36" GATE, W/ PANIC

HARDWARE

EXISTING DRIVEWAY/

APPROACH

EXIST'G ROOF OVERHANG

EXISTING CANOPY

STRUCTURE

EXISTING

CONCRETE

SIDEWALK TO

REMAIN

5'- 0"

6'-0" 5'-0" 6'-0"

EXISTING CONCRETE

SIDEWALK AND PAVER

PATIO TO REMAIN

6'-0"

6"

PROPOSED ADDITION

= 523 S.F.

EXISTING SIGN

'-0

15'-0"

10'-0"

S01

S01

S02 S02

S02

9'-6"

S04

S05 S06

S06

S07

S08

S09 S09

S10

S10

S11

S11

S11

S12

S12

S12

S13

S13 10'-9" S15

S14

ONLY

DO NOT ENTER

ONLY

DO

N

OT

E

NT

ER

S16

S16

S16

S16

S17

DNDN

NEW 4" CONCRETE SIDEWALK TO REPLACE EXIST'G;

BROOM FINISH

NEW CONC. RAMP DOWN (1:12 SLOPE, 6" RISE), TYP.

EA. SIDE OF LANDING

NEW CONC. LANDING FLUSH W/ PAVING; W/ 24"

WIDE DETECTABLE WARNING STRIP AT PAVING

EDGE

NEW 4" CONCRETE SLAB AT ENTRY

ALIGN NEW CURB W/ EXISTING

ASPHALT PATCH AS REQ'D AS REQUIRED FOR NEW

SIDEWALK/ CURB

NEW AT-GRADE SIGN LIGHT; TYP. EA. SIDE

NEW WHEEL STOP, TYP.

EXISTING 12' LIGHT POLE, WITH NEW DUAL HEAD

LED AREA LIGHTS PER SCHEDULE.

EXISTING 12' LIGHT POLE, WITH NEW SINGLE HEAD

LED AREA LIGHT PER SCHEDULE.

ADD ALTERNATE #1: DEMO EXISTING PERIMETER

FENCE. INSTALL NEW 8' CHAIN LINK FENCE W/ PVC

PRIVACY SLATS, TYP. 3 SIDES. DEMO EXISTING

LANDSCAPING AS REQ'D FOR INSTALL OF NEW

FENCE.

ADD ALTERNATE #2: INSTALL NEW 8' CHAIN LINK

FENCE

ADD ALTERNATE #2: INSTALL NEW 15' WIDE

ROLLING GATE, 8' TALL; MOTORIZED, WITH EXIT

AND SAFETY SENSORS, W/ RFID AND KEY PAD

ENTRY ON POST. PROVIDE POWER AND LOW

VOLTAGE IN SEPARATE CONDUITS FROM BUILDING

TO OPERATORS AND MAKE ALL REQUIRED

CONNECTIONS. PATCH AND REPAIR ASPHALT AND

CONCRETE PAVING AS REQUIRED.

ADD ALTERNATE #2: NEW 3' WIDE CHAIN LINK EXIT

GATE, WITH EXTERIOR-RATED EXIT HARDWARE

AND SECURITY PLATE

ADD ALTERNATE #2: NEW CURB, WITH 36" WIDE

ASPHALT STRIP FOR GATE STACKING

NEW PAINTED DIRECTIONAL ARROW (WHITE), TYP.;

W/ TEXT AS INDICATED

ADD ALTERNATE #1: RETAIN AND REINSTALL

EXISTING ACCESSIBLE PARKING SIGN AT THE HEAD

OF ACCESSIBLE PARKING SPACE, TYP. (2) LOC'S)

S01

S02

S03

S04

S05

S06

S07

S08

S09

S10

S11

S12

S13

S14

S15

S16

S17 project name

12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com

UNPUBLISHED WORK

© 2024 MERRICK LENTZ ARCHITECT

Unauthorized use or reproduction of these drawings or any part herein without the permission of

Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title

MDL

design development

11/18/24 RFP SET

Simonka Place Union Gospel Mission

5119 River Road North Keizer, OR 97303

Addition and

Interior Alteration

12/19/24 UPDATED RFP SET

SCALE: 1" = 20'-0"

SITE PLAN

SITE PLAN NOTES

A1.1

SITE PLAN

AutoCAD SHX Text R I V E R R O A D N O R T H

AutoCAD SHX Text

S1°56'OO" W 163.02'

AutoCAD SHX Text N0°16'3O"E 163.00'

AutoCAD SHX Text S86°44'42"E 445.04'

AutoCAD SHX Text N86°44'42"W 446.11'

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .