UGM Simonka_A2.2 CEILING PLAN_12.19.24.pdf

PDF 540 KB Posted

Attached to
Union Gospel Mission - Construction Services at Simonka Place Women's Shelter
Solicitation number
S-C25102-00012036
Issued by
Marion County, Junction City, Oregon

About this file

This is a reflected ceiling and lighting plan drawing for the Union Gospel Mission's Simonka Place renovation project in Keizer, Oregon, prepared by Merrick Lentz Architect. The drawing details modifications to existing HVAC supply, ductwork, and fire protection systems throughout new and modified rooms. It specifies repairs and replacements to existing ceilings at demolished walls using 5/8" Type "X" GWB (gypsum wall board) on existing suspension systems, with finishes to match existing conditions.

The plan includes detailed annotations for new surface-mounted light fixtures with associated J-boxes and circuiting requirements, removal and replacement of existing recessed troffers, and patches to match existing ceiling textures. Multiple ceiling elements are labeled with various codes (D1, D2, D3, B1, T1, L1, L2, L3, F1, etc.) indicating different components and modifications throughout the space. The drawing is dated December 19, 2024, marked as an "UPDATED RFP SET" at 1/8" = 1'-0" scale, and includes specifications for new suspended GWB ceilings that must be flush with existing ceilings. Several areas indicate "EXISTING LIGHTING TO REMAIN" and show an existing roof access ladder to be maintained.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MODIFY EXISTING HVAC SUPPLY

AND DUCTWORK AS REQ'D; MODIFY

EXISTING FIRE PROTECTION AS

REQ'D, TYP. @ NEW AND MODIFIED

ROOMS

REPAIR/REPLACE EXIST'G CEILING AS

REQ'D AT DEMO'D WALLS; 58" TYPE "X"

GWB, FLUSH W/ EXIST'G ON EXISTING

SUSPENSION SYSTEM; MATCH EXIST'G

FINISH, TYP.

SS

REPAIR/REPLACE EXIST'G CEILING AS

REQ'D AT DEMO'D WALLS; 58" TYPE "X"

GWB, FLUSH W/ EXIST'G ON EXISTING

SUSPENSION SYSTEM; MATCH EXIST'G

FINISH, TYP.

REMOVE EXISTING RECESSED

TROFFER; PATCH AND REPAIR GWB

TO MATCH EXIST'G CEILING

TEXTURE; W/ NEW J-BOX FOR NEW

FIXTURE WHERE REQ'D, TYP.

NEW SURFACE-MOUNTED

FIXTURE, TYP.; PROVIDE

NEW J-BOX AND CIRCUITING

WHERE REQUIRED

D3

D2 D1

D3

D3

D3

D3

D3D3

D3

D3 D3

D3D3

D3 D3

D3 D3

D3 D3

D3D3

D3 D3

D3 D3

D3 D3

D3 D3 D3

D3 D3

D3

D3

D3

D1

D1

D1

D1

D1

D1D1

D1D1 D1 D1 D1D1D1D1D1

D2

D2

D2 D2

D2

D2

D2

D2

D2

D2

D2

D2D2D2

D2

D2

D2

D2

D2D2

D2D2

D2 D2 D2 D2

D2D2

D2

D2

D2

D2

D2

D2

D2

D2

D2

D2 D2

D2

D2

D2

D3

D3 D3

D3 D3

D3 D3

D3 D3

D3 D3

D3

D1

D1

D1

D1 D1 D1 D1 D1

D2

D2

D2

D2

D3 D3

D3D3 D3 D3

D3 D3

D3

D3

D3

D3

D3

P1P1P1

P2 P2

D2 D2

D2D2

B1B1B1B1B1B1B1B1B1B1

B1

B1

B1

B1B1B1B1B1B1B1B1B1

B1B1

B1

B1

B1

B1

B1

B1

B1B1

B1 B1 B1 B1

B1

B1

B1

B1

B1

T1

T1

T1T1

T1

T1T1

T1

T1 T1

T1

T1

D2

T1

T1

T1 T1

T1 T1

L1 L1 L1

L2

L2 L2 L2 L2 L2 L2

L2

L2 L2 L2 L2 L2 L2 L2

L2 L2 L2 L2

L3

L3

L3

L3

L3

L3

L3

L3

L3

L1

L1

NEW SUSPENDED

GWB CEILING PER

1/A2.2.1, TYP; FLUSH

W/ EXISTING

P2

EXISTING LIGHTING

TO REMAIN

EXISTING LIGHTING

TO REMAIN

EXISTING LIGHTING

TO REMAIN

EXISTING LIGHTING

TO REMAIN

EXISTING LIGHTING

TO REMAIN

D1

F1F1F1F1F1

F1

F1

F1F1F1F1

F1

F1

F1

F1

F1

F1

F1

F1

F1 F1

F1 F1

F1 F1 F1 F1 F1

F1

F1 F1F1

F1F1

D2

F1

EXISTING LIGHTING

TO REMAIN

D2

EXISTING ROOF

ACCESS LADDER

TO REMAIN

L3L3L3L3

REMOVE EXISTING RECESSED

TROFFER; PATCH AND REPAIR GWB

TO MATCH EXIST'G CEILING TEXTURE

NEW SURFACE-MOUNTED

FIXTURE, TYP.; W/ NEW J-BOX

AND CIRCUITING AS REQ'D; BY

ELECTRICAL DESIGN-BUILD

S1

WP1

EXISTING LIGHTING

TO REMAIN

EXISTING LIGHTING

TO REMAIN

B1

NEW SUSPENDED

GWB CEILING,

FLUSH W/ EXISTING

project name

12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com

UNPUBLISHED WORK

© 2024 MERRICK LENTZ ARCHITECT

Unauthorized use or reproduction of these drawings or any part herein without the permission of

Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title

MDL

design development

11/18/24 RFP SET

Simonka Place Union Gospel Mission

5119 River Road North Keizer, OR 97303

Addition and

Interior Alteration

12/19/24 UPDATED RFP SET

SCALE: 1/8" = 1'-0"

REFLECTED CEILING/LIGHTING PLAN

A2.2

REFLECTED

CEILING/

LIGHTING PLAN

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .