This file contains architectural elevation drawings from Merrick Lentz Architect for the Union Gospel Mission's Simonka Place renovation project in Keizer, Oregon. The drawings show detailed exterior elevations for all four sides (East, West, North, and South) of the facility, including specifications for new siding, windows, trim, flashing, and other exterior components. The drawings are dated December 19, 2024, and are marked as "UPDATED RFP SET," indicating they are part of the request for proposal documentation.
The elevation drawings include extensive notes detailing materials and construction specifications, such as 5/16" F.R.C. panels with vertical battens, manufactured stone cladding, window replacements, aluminum screen walls, and various trim pieces. The drawings also indicate existing elements that will remain, including composition roofing, vertical channel siding, and CMU walls. The scale used for all elevations is 1/8" = 1'-0", and the drawings include multiple reference points to other architectural details and cross-sections. This documentation will be used by contractors to prepare bids for the exterior renovation portion of the $3.38 million construction project.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING COMPOSITION
ROOFING TO REMAIN
P101
P102
7'- 0"
2'- 0"
5'- 6"
1'- 6"
9'- 9"
1'- 3"
8'- 6"
P101 P103
P103
P103
06 0707
NEW SIDING OVER EXISTING SUBSTRATE, THUS: 5/16"
F.R.C. PANEL W/ 1x2 F.R.C. VERT BATTENS AT 24" O.C., OVER 1x4@16"o.c. RAINSCREEN FURRING, OVER NEW
W.R.B., OVER EXISTING PLYWOOD SHTH'G. REPLACE
EXISTING DAMAGED PLYWOOD SHTH'G WHERE REQ'D.
NEW SIDING AT NEW ADDITION, THUS: 5/16" F.R.C. PANEL
W/ 1x2 F.R.C. VERT BATTENS AT 24" O.C., OVER 1x4@16"o.c. RAINSCREEN FURRING, OVER W.R.B.
NEW 5/16" F.R.C. PANEL FASCIA OVER NEW W.R.B.
NEW VENEER MANUFACTURERED STONE CLADDING PER
SCHEDULE.
NEW WINDOW PER SCHEDULE W/IN EXISTING OPENING,
TO REPLACE EXISTING.
NEW WINDOW PER SCHEDULE IN NEW/MODIFIED
OPENING.
NEW CONT. 5/4 x 6 F.R.C. BASE TRIM W/ Z-FLASHING
OVER
NEW CONT. 1 x 3 F.R.C. RUNNING TRIM W/ Z-FLASHING
NEW CONT. 3/4" x 4 1/2" RUNNING TRIM W/ Z-FLASHING
NEW CONT. 1 x 4 F.R.C. RUNNING TRIM W/ Z-FLASHING
NEW 1 x 3 F.R.C. CORNER STANDING TRIM
NEW 1 x 3 F.R.C. CASING, TYP. ALL AROUND WINDOWS
NEW 5/4" x _ F.R.C. FASCIA
NEW PREFIN. METAL EDGE FLASHING; COLOR
INDICATED.
NEW COLUMN, REFER STRUCTURAL; W/ 5/16" F.R.C.
PANEL CLADDING EA. SIDE.
NEW ALUMINUM SCREEN WALL: 1.5"x4" ALUMINUM TUBE, POWDER COATED (COLOR TBD)
INFILL PORTION OF EXISTING WINDOW OPENING AS
REQ'D FOR NEW CLERESTORY WINDOW
NEW PREFIN. METAL FLASHING CAP
NEW 1 x 3 STANDING TRIM
NEW 1 x _ STANDING TRIM
NEW 5/4" x _ CONT. RUNNING EAVE TRIM
NEW PREFIN. METAL GABLE FLASHING
NEW PREFIN. METAL GUTTER; TO REPLACE EXISTING
WHERE APPLICABLE
NEW PREFIN. METAL DOWNSPOUT; TO REPLACE
EXISTING WHERE APPLICABLE. TIE INTO EXISTING
DRAINAGE SYSTEM CONNECTION POINTS
PAINT EXISTING CMU AND CONCRETE COLUMN, MATCH
PRIMARY BODY COLOR
2008 ADDITIONORIGINAL BUILDING
EXISTING COMPOSITION
ROOFING TO REMAIN
EXISTING VERT. CHANNEL
SIDING TO REMAIN
PLATE
LINE
8'- 0"
EXISTING COMPOSITION
ROOFING TO REMAIN
P102
P103 P103
P101
05 05 05 050506 07 07 070606
P121
C A4.1
B A4.1
A A4.1
4A A5.1
4A A5.1
4A A5.1
4A A5.1
SIM
SIM 3
A5.1
LOW SLOPE SINGLE
PLY ROOFING BEYOND
EXISTING BUILDING BEYOND
PLATE
LINE
EXISTING COMPOSITION
ROOFING
EXISTING ROOF FASCIA
TO REMAIN
EXISTING ROOF
FASCIA TO REMAIN
EXISTING COMPOSITION
ROOFING TO REMAIN
EXISTING VERT. CHANNEL
SIDING TO REMAIN
EXISTING CMU TO REMAIN
P103
P101 07
EXISTING LOW SLOPE
SINGLE PLY ROOFING
EXISTING PARAPET WALL
BEYOND
EXISTING BUILDING BEYOND
TO REMAIN
PLATE
LINE
8'- 0"
PLATE
LINE
PLATE
LINE
'-0
8'- 0"
EXISTING VERT. CHANNEL
SIDING TO REMAIN
EXISTING ROOF FASCIA
TO REMAIN
EXISTING ROOF FASCIA
TO REMAIN
project name
12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com
UNPUBLISHED WORK
© 2024 MERRICK LENTZ ARCHITECT
Unauthorized use or reproduction of these drawings or any part herein without the permission of
Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title
MDL
design development
11/18/24 RFP SET
Simonka Place Union Gospel Mission
5119 River Road North Keizer, OR 97303
Addition and
Interior Alteration
12/19/24 UPDATED RFP SET
SCALE: 1/8" = 1'-0"
A
A3.1
EXTERIOR ELEVATION - EAST
EXTERIOR ELEVATION NOTES
A3.1
EXTERIOR
ELEVATIONS
SCALE: 1/8" = 1'-0"
B
A3.1
EXTERIOR ELEVATION - WEST
SCALE: 1/8" = 1'-0"
C
A3.1
EXTERIOR ELEVATION - NORTH
SCALE: 1/8" = 1'-0"
D
A3.1
EXTERIOR ELEVATION - SOUTH
| Sheets and Views |