About this file

This file contains architectural elevation drawings from Merrick Lentz Architect for the Union Gospel Mission's Simonka Place renovation project in Keizer, Oregon. The drawings show detailed exterior elevations for all four sides (East, West, North, and South) of the facility, including specifications for new siding, windows, trim, flashing, and other exterior components. The drawings are dated December 19, 2024, and are marked as "UPDATED RFP SET," indicating they are part of the request for proposal documentation.

The elevation drawings include extensive notes detailing materials and construction specifications, such as 5/16" F.R.C. panels with vertical battens, manufactured stone cladding, window replacements, aluminum screen walls, and various trim pieces. The drawings also indicate existing elements that will remain, including composition roofing, vertical channel siding, and CMU walls. The scale used for all elevations is 1/8" = 1'-0", and the drawings include multiple reference points to other architectural details and cross-sections. This documentation will be used by contractors to prepare bids for the exterior renovation portion of the $3.38 million construction project.

View the file

Other files

Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING COMPOSITION

ROOFING TO REMAIN

P101

P102

7'- 0"

2'- 0"

5'- 6"

1'- 6"

9'- 9"

1'- 3"

8'- 6"

P101 P103

P103

P103

06 0707

NEW SIDING OVER EXISTING SUBSTRATE, THUS: 5/16"

F.R.C. PANEL W/ 1x2 F.R.C. VERT BATTENS AT 24" O.C., OVER 1x4@16"o.c. RAINSCREEN FURRING, OVER NEW

W.R.B., OVER EXISTING PLYWOOD SHTH'G. REPLACE

EXISTING DAMAGED PLYWOOD SHTH'G WHERE REQ'D.

NEW SIDING AT NEW ADDITION, THUS: 5/16" F.R.C. PANEL

W/ 1x2 F.R.C. VERT BATTENS AT 24" O.C., OVER 1x4@16"o.c. RAINSCREEN FURRING, OVER W.R.B.

NEW 5/16" F.R.C. PANEL FASCIA OVER NEW W.R.B.

NEW VENEER MANUFACTURERED STONE CLADDING PER

SCHEDULE.

NEW WINDOW PER SCHEDULE W/IN EXISTING OPENING,

TO REPLACE EXISTING.

NEW WINDOW PER SCHEDULE IN NEW/MODIFIED

OPENING.

NEW CONT. 5/4 x 6 F.R.C. BASE TRIM W/ Z-FLASHING

OVER

NEW CONT. 1 x 3 F.R.C. RUNNING TRIM W/ Z-FLASHING

NEW CONT. 3/4" x 4 1/2" RUNNING TRIM W/ Z-FLASHING

NEW CONT. 1 x 4 F.R.C. RUNNING TRIM W/ Z-FLASHING

NEW 1 x 3 F.R.C. CORNER STANDING TRIM

NEW 1 x 3 F.R.C. CASING, TYP. ALL AROUND WINDOWS

NEW 5/4" x _ F.R.C. FASCIA

NEW PREFIN. METAL EDGE FLASHING; COLOR

INDICATED.

NEW COLUMN, REFER STRUCTURAL; W/ 5/16" F.R.C.

PANEL CLADDING EA. SIDE.

NEW ALUMINUM SCREEN WALL: 1.5"x4" ALUMINUM TUBE, POWDER COATED (COLOR TBD)

INFILL PORTION OF EXISTING WINDOW OPENING AS

REQ'D FOR NEW CLERESTORY WINDOW

NEW PREFIN. METAL FLASHING CAP

NEW 1 x 3 STANDING TRIM

NEW 1 x _ STANDING TRIM

NEW 5/4" x _ CONT. RUNNING EAVE TRIM

NEW PREFIN. METAL GABLE FLASHING

NEW PREFIN. METAL GUTTER; TO REPLACE EXISTING

WHERE APPLICABLE

NEW PREFIN. METAL DOWNSPOUT; TO REPLACE

EXISTING WHERE APPLICABLE. TIE INTO EXISTING

DRAINAGE SYSTEM CONNECTION POINTS

PAINT EXISTING CMU AND CONCRETE COLUMN, MATCH

PRIMARY BODY COLOR

2008 ADDITIONORIGINAL BUILDING

EXISTING COMPOSITION

ROOFING TO REMAIN

EXISTING VERT. CHANNEL

SIDING TO REMAIN

PLATE

LINE

8'- 0"

EXISTING COMPOSITION

ROOFING TO REMAIN

P102

P103 P103

P101

05 05 05 050506 07 07 070606

P121

C A4.1

B A4.1

A A4.1

4A A5.1

4A A5.1

4A A5.1

4A A5.1

SIM

SIM 3

A5.1

LOW SLOPE SINGLE

PLY ROOFING BEYOND

EXISTING BUILDING BEYOND

PLATE

LINE

EXISTING COMPOSITION

ROOFING

EXISTING ROOF FASCIA

TO REMAIN

EXISTING ROOF

FASCIA TO REMAIN

EXISTING COMPOSITION

ROOFING TO REMAIN

EXISTING VERT. CHANNEL

SIDING TO REMAIN

EXISTING CMU TO REMAIN

P103

P101 07

EXISTING LOW SLOPE

SINGLE PLY ROOFING

EXISTING PARAPET WALL

BEYOND

EXISTING BUILDING BEYOND

TO REMAIN

PLATE

LINE

8'- 0"

PLATE

LINE

PLATE

LINE

'-0

8'- 0"

EXISTING VERT. CHANNEL

SIDING TO REMAIN

EXISTING ROOF FASCIA

TO REMAIN

EXISTING ROOF FASCIA

TO REMAIN

project name

12815 NE 126th Place, Kirkland, WA 98034 t.425.747.3177 www.mlarch.com

UNPUBLISHED WORK

© 2024 MERRICK LENTZ ARCHITECT

Unauthorized use or reproduction of these drawings or any part herein without the permission of

Merrick Lentz Architect is not permitted consultant stamp descriptionissued date checked by drawn by CSC drawing title

MDL

design development

11/18/24 RFP SET

Simonka Place Union Gospel Mission

5119 River Road North Keizer, OR 97303

Addition and

Interior Alteration

12/19/24 UPDATED RFP SET

SCALE: 1/8" = 1'-0"

A

A3.1

EXTERIOR ELEVATION - EAST

EXTERIOR ELEVATION NOTES

A3.1

EXTERIOR

ELEVATIONS

SCALE: 1/8" = 1'-0"

B

A3.1

EXTERIOR ELEVATION - WEST

SCALE: 1/8" = 1'-0"

C

A3.1

EXTERIOR ELEVATION - NORTH

SCALE: 1/8" = 1'-0"

D

A3.1

EXTERIOR ELEVATION - SOUTH

Sheets and Views
a3.1

File details come from the government source that posted it. Updated .