This is a Motor Megger Report dated March 3, 2023, for the TS FREEDOM STAR vessel at Colonna's Shipyard in Norfolk, Virginia. The report documents electrical resistance measurements between phases on cables at 16 motor controllers, performed using a FLUKE 1507 Megohmmeter set to 500V signal. The testing was conducted in the presence of ship's force and in accordance with ABS requirements.

The report includes detailed megohm readings for various ship systems including STBD CPP pumps, port CPP pumps, F.O. transfer pumps, fire & bilge pumps, steering gear pumps, anchor windlass hydraulic pump, bow thruster hydraulic power unit, ER supply fans, and engine room exhaust fan. All tests were satisfactory, with most readings around 550 megohms. The report notes that the F.O. Purifier system (#16) is non-operational and no longer in use. The testing was performed by I. Johansson from Shop 403 and approved by PM/Superintendent Gallegos/Johansson.

View the file

Other files

File Type Posted
Crane rope cert.pdf PDF
1547 4411 Rev 5 Machinery Arrgmt.pdf PDF
Tow Winch Pic 2.jpg JPG image
1547L F 54 Rev 4 Barge Towing Arr and Det.pdf PDF
Sullair Compressor Pic.jpg JPG image
1547L P72 Rev 2 Towing winch Power and controls.pdf PDF
AMD 0002 Drydock 2025 Questions and Answers 2.pdf PDF
P00002 6933A225Q000001 .pdf PDF
crane cab rough dimensions.pdf PDF
Tow Winch Pic 1.jpg JPG image
AMD0001 6933A225Q000001 .pdf PDF
Item 225 Photo.jpg JPG image
Item 226 Fassmer FRB.pdf PDF
DB Design PURY P T Y S KMU A BS MEES17K096 201802.pdf PDF
Item 225 SH PLFY P NCMU E OCH410D Parts OCB410D 1.pdf PDF
AMD 00001 TSFS Drydock 2025 Questions and Answers.pdf PDF
Item 226 Global Davit Catalogue 2016.pdf PDF
Item 225 DB PUHY P T Y S KMU A BS U11 E2 3.pdf PDF
FREEDOM STAR ON 629627 Trim and Stability Booklet Rev D.pdf PDF
1547 4411 Rev 5 Machinery Arrgmt.pdf PDF
1547-4701 Rev 3 Rudder Arr 3.pdf PDF
MA-57 Dry dock Report 3.pdf PDF
1547-4420 Rev 3 Bow Thruster Arr 3.pdf PDF
FREEDOM STAR ON 629627 Trim and Stability Booklet Rev D 1.pdf PDF
Stern Thruster Mechanical manual G569W G570W 32HJP 4.pdf PDF
TSFS 2023 Anchor Chain Gauging Report 2.pdf PDF
Shaft Liners 2.pdf PDF
TSFS Wartsila Tailshaft Parts 2024 1.pdf PDF
Stern Thruster 2768WG-D 32HJP SECTIONAL ARRANGEMENET 1.pdf PDF
Sherwin Williams Coating Spec 04-12-2024 2.pdf PDF
1316-901 Kings Pointer Docking Plan 3.pdf PDF
FREEDOM STAR MEGGER READINGS blank 1.docx DOCX document
2018 Bow Thruster Maintenance - Final Service Report 1.pdf PDF
1780-4419 Stern Thruster Compt Arrangement1of1 3.pdf PDF
TV KINGS POINTER Docking Calculations 2.pdf PDF
Crane Diesel Manual 1.pdf PDF
TSFS FY25 CSS 6933A225Q000001 FINAL.pdf PDF
1547-1420 Docking Plan 3.pdf PDF
1547-2510 Rev 7 Long l Struct Sections 3.pdf PDF
Sullair ES6 2.pdf PDF
1547-4801 Rev 4 Shafting Arr and Det 2.pdf PDF
2020 Bow Thruster Maintenance Report 1.pdf PDF
ABS Rules Part 7 Chapter 6 4.pdf PDF
TSFS 2023 Anode Locations 2.pdf PDF
TS FREEDOM STAR - Signed CFR 014 Tailshaft Bearing Clearances WI 202 1.pdf PDF
2023 Freedom Star Gauge Calibration List 1.xls XLS spreadsheet
4163B-M20 Bow Thruster Arrangement Omega OCP-400 1.pdf PDF
TSFS Gauge Calibration Final Report 2023 1.pdf PDF
Attmt II TSFS VENDOR PRICE SHEET (SECTION B) .xlsx XLSX spreadsheet
ABS Rules Part 7 Chapter 5 Sections 1 and 2 3.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Ship & Hull Number CSI REPORT #

3/3/2023 TS FREEDOM STAR 034

Item Title / Subject Required Report Growth / New Work Contract #

Motor Megger Report Yes No Yes No

Description of Conditions Found

KTR was tasked to measure resistance between phases on cables at 16ea. motor controllers per ABS and list provided by COR. The test was conducted in the presence of ship’s force using the 500V signal setting. Upon inspecting and testing, KTR discovered that F.O Purifier is non-operational and is no longer in use.

See attached report. All tests were SAT.

Recommended Repairs

Accept report.

Material Required: List all models, serials, type, quantities, size, type of material, etc.

(1) FLUKE 1507 Megohmmeter, Cal. Date=April 18th,2022 Cal. Due=April 18th,2023, CSI#2857-01

Colonna’s Representative Print / Sign Name Port Engineer Action/Comments

Originator: I. Johansson Shop: 403 Date: 3/3/2023

PM/Superintendent: Gallegos / Johansson Date: 3/3/2023

CSI-FM-005 (REV 01.25.16)

Colonna’s Job #

Spec. Item #/ Work Item #

Item Para Std Item Std Item Para

Colonna’s Work Order #

40745 Ch 009 N/A N/A N/A

COLONNA’S SHIPYARD, INC.

Norfolk, Virginia

Condition / Required Report

CSI-FM-005 (REV 01.25.16)

X X

SHOP

DISTRIBUTION

Received

03-03-2023 timothy.mcgeein Stamp

File details come from the government source that posted it. Updated .