2018 Bow Thruster Maintenance - Final Service Report 1.pdf
PDF 1 MB Posted
- Attached to
- TRAINING VESSEL FREEDOM STAR(TVFS) FY25 DRY DOCK
- Solicitation number
- 6933A225Q000001
About this file
This is a condition/required report from Colonna's Shipyard documenting bow thruster maintenance performed on the vessel Freedom Star, along with an attached service report from BNA Marine Services detailing the maintenance work conducted from June 25-July 5, 2018.
The maintenance involved an Omega OCP 400 bow thruster unit, which underwent comprehensive inspection and repairs. Initial findings showed proper thrust lift measurements but indicated leakage around the blades/seals from an undersized O-ring. The work included removal of blades for cleaning and NDT testing, complete thruster removal and disassembly, replacement of various seals and bearings, and repairs to the O-ring groove area using metal epoxy. Multiple tests were conducted including pitch testing for ABS certification. The root cause of the original leak was determined to be an undersized O-ring (6mm) installed during previous yard work; this was corrected by installing the proper 7mm O-ring with flange sealant 574. The work was performed at Colonna's Shipyard in Norfolk, VA by BNA Marine Services technician Rick Hartenstine, with Job #40654 and Work Order #2130-001.
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date Ship & Hull Number CSI REPORT #
7/10/2018 FREEDOM STAR 046
Item Title / Subject Required Report Growth / New Work Contract #
Bow Thruster Maintenance Yes No Yes No
Description of Conditions Found
Please see the attached final service report from OEM technical representative BNA Marine Services for work performed on the Freedom Star bow thruster.
Recommended Repairs
Please accept the required report.
Material Required: List all models, serials, type, quantities, size, type of material, etc.
N/A
Colonna’s Representative Print / Sign Name Port Engineer Action/Comments
Originator: B. Zeman Shop: 403 Date: 7/10/2018
Superintendent / PM: Cook / Zeman Date: 7/10/2018
CSI‐FM‐005 (REV 01.25.16)
Colonna’s Job # Spec. Item # Colonna’s Work Order #
40654 213 2130‐001
COLONNA’S SHIPYARD, INC.
Norfolk, Virginia
Condition / Required Report
CSI‐FM‐005 (REV 01.25.16)
X X
SHOP
DISTRIBUTION