TV KINGS POINTER Docking Calculations 2.pdf

PDF 12 KB Posted

Attached to
TRAINING VESSEL FREEDOM STAR(TVFS) FY25 DRY DOCK
Solicitation number
6933A225Q000001
Issued by

About this file

This is a docking calculations document for the Training Vessel (T/V) KINGS POINTER, prepared by Beckley Engineering Co., Inc. on February 23, 2015.

The document details stability and docking calculations for a vessel with a full load displacement of 963.08 long tons. Key specifications include: 20 keel blocks with dimensions of 48x28 inches and contact area of 168 square inches each, allowable pressure of 370 psi, and maximum allowable load of 27.75 long tons per block. The vessel has a length between perpendiculars (LBP) of 166 feet, drafts of approximately 11.31 feet, and a metacentric height (GMo) of 6.153 feet. The calculations confirm the vessel's stability parameters, including knuckle reaction at the aftmost keel block (0.22 long tons) and seismic overturning resistance requiring 7 side blocks per side, which exceeds the minimum requirement of 4.01 blocks. All calculations are noted as "OK" or within acceptable parameters, with no deviations from Docking Plan 1316-901.

View the file

Other files

File Type Posted
Crane rope cert.pdf PDF
1547 4411 Rev 5 Machinery Arrgmt.pdf PDF
Tow Winch Pic 2.jpg JPG image
1547L F 54 Rev 4 Barge Towing Arr and Det.pdf PDF
Sullair Compressor Pic.jpg JPG image
1547L P72 Rev 2 Towing winch Power and controls.pdf PDF
AMD 0002 Drydock 2025 Questions and Answers 2.pdf PDF
P00002 6933A225Q000001 .pdf PDF
crane cab rough dimensions.pdf PDF
Tow Winch Pic 1.jpg JPG image
AMD0001 6933A225Q000001 .pdf PDF
Item 225 Photo.jpg JPG image
Item 226 Fassmer FRB.pdf PDF
DB Design PURY P T Y S KMU A BS MEES17K096 201802.pdf PDF
Item 225 SH PLFY P NCMU E OCH410D Parts OCB410D 1.pdf PDF
AMD 00001 TSFS Drydock 2025 Questions and Answers.pdf PDF
Item 226 Global Davit Catalogue 2016.pdf PDF
Item 225 DB PUHY P T Y S KMU A BS U11 E2 3.pdf PDF
FREEDOM STAR ON 629627 Trim and Stability Booklet Rev D.pdf PDF
1547 4411 Rev 5 Machinery Arrgmt.pdf PDF
1547-4701 Rev 3 Rudder Arr 3.pdf PDF
MA-57 Dry dock Report 3.pdf PDF
1547-4420 Rev 3 Bow Thruster Arr 3.pdf PDF
FREEDOM STAR ON 629627 Trim and Stability Booklet Rev D 1.pdf PDF
Stern Thruster Mechanical manual G569W G570W 32HJP 4.pdf PDF
TSFS 2023 Anchor Chain Gauging Report 2.pdf PDF
Shaft Liners 2.pdf PDF
TSFS Wartsila Tailshaft Parts 2024 1.pdf PDF
Stern Thruster 2768WG-D 32HJP SECTIONAL ARRANGEMENET 1.pdf PDF
TSFS 2023 Motor Megger Report 3.pdf PDF
Sherwin Williams Coating Spec 04-12-2024 2.pdf PDF
1316-901 Kings Pointer Docking Plan 3.pdf PDF
FREEDOM STAR MEGGER READINGS blank 1.docx DOCX document
2018 Bow Thruster Maintenance - Final Service Report 1.pdf PDF
1780-4419 Stern Thruster Compt Arrangement1of1 3.pdf PDF
Crane Diesel Manual 1.pdf PDF
TSFS FY25 CSS 6933A225Q000001 FINAL.pdf PDF
1547-1420 Docking Plan 3.pdf PDF
1547-2510 Rev 7 Long l Struct Sections 3.pdf PDF
Sullair ES6 2.pdf PDF
1547-4801 Rev 4 Shafting Arr and Det 2.pdf PDF
2020 Bow Thruster Maintenance Report 1.pdf PDF
ABS Rules Part 7 Chapter 6 4.pdf PDF
TSFS 2023 Anode Locations 2.pdf PDF
TS FREEDOM STAR - Signed CFR 014 Tailshaft Bearing Clearances WI 202 1.pdf PDF
2023 Freedom Star Gauge Calibration List 1.xls XLS spreadsheet
4163B-M20 Bow Thruster Arrangement Omega OCP-400 1.pdf PDF
TSFS Gauge Calibration Final Report 2023 1.pdf PDF
Attmt II TSFS VENDOR PRICE SHEET (SECTION B) .xlsx XLSX spreadsheet
ABS Rules Part 7 Chapter 5 Sections 1 and 2 3.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Beckley Engineering Co., Inc. T/V KINGS POINTER

DOCKING CALCULATIONS

Rev -, 23 Feb 2015

STABILITY

Displacement, SW 963.08 Lton Full Load Displacement Displacement, FW

Stability Draft @ LCF 11.311 ft KMt 19.725 ft KG 13.307 ft GM, uncorrected 6.418 ft F.S. corr'n 0.265 ft GMo 6.153 ft

Drafts & Trim LCB 87.75 ft, aft FP LCG 87.74 ft, aft FP Trim Lever -0.01 ft MCT1" 109.64 ft-Lton/inch Trim 0.007 ft LCF 93.22 aft of FP, m Draft, FP 11.318 ft Draft, MP 11.311 ft Draft, AP 11.311 ft

Draft, Fwd Marks 11.317 ft Draft, Mid Marks 11.311 ft Draft, Aft Marks 11.311 ft

DOCKING CALCULATIONS LOAD DISTRIBUTION ON BLOCKS

Docking Position No 1 MILSTD 1625C LBP 166 ft Keel Block Capacity SRP 0 ft No. of blocks 20 LCG 87.74 ft aft FP block size 48x28 OHA 30 ft contact area 168 sq in, each W 963.08 Lton Allowable Pressure 370 psi Lk 116.33 ft Max Allowable Load 27.75 Lton Cb 58.165 ft

B 19.388 A 9.905

MAX BLOCK LOADING 29.14 Lton LOADmax 12.51 Lton/ft MIN BLOCK LOADING 9.44 Lton LOADmin 4.05 Lton/ft

OK!

Deviations from Docking Plan 1316-901 NONE

Beckley Engineering Co., Inc. T/V KINGS POINTER

DOCKING CALCULATIONS

Rev -, 23 Feb 2015

KNUCKLE REACTION AT AFTMOST KEEL BLOCK

Trim 0.01 ft (+ by stern) MCT1" 109.64 ft-Ltons/in k 0.97 Dist from Knuckle block to LCF, Xkn 42.78 ft

Knuckle Reaction 0.22 Ltons OK!

DRAFT AT LANDING, H1

Knuckle reaction 0.22 Lton TPI 11.36 Lton/in H1 = 11.31 ft

DRAFT AT INSTABILITY, H2

draft KMt Displ'ment Product

9.00 19.86 663 13166

9.50 19.79 724 14326

10.00 19.80 787 15581

10.50 19.73 852 16805

11.00 19.72 918 18107

11.50 19.72 986 19449

Kgo * Displ'ment = 18996.75 ft-Lton H2=11.31 thus, H2 <= H1 OK!

NUMBER OF SIDE BLOCKS REQUIRED

TO RESIST SIESMIC OVERTURNING

Displacement 963.08 Ltons KG o 19.99 ft ABL g 0.2 acceleration Ms 8624882.202 ft-lbs

A2 80% contact, mean 336 in2 24"x28", 50% contact Sp 800 psi L2 8 ft mean

N2 No. of side blocks 4.01 required

Actual No. per side 7 OK !!