This is a condition report and anchor chain inspection report for the TS Freedom Star vessel, conducted by Colonna's Shipyard in Norfolk, Virginia on March 23, 2023. The inspection found two damaged links on the starboard anchor chain that require replacement - one deformed/bent link in shot #5 and one gouged link in shot #3.
The inspection includes detailed gauging measurements for both port and starboard anchor chains, showing measurements for inside, outside, and average dimensions across multiple shots. The original chain size is 1.25 with a wear limit of 0.15 and minimum wear of 1.1. The recommended repairs specify replacing the bent link with a government-furnished material (GFM) detachable link and completely removing the gouged link before reassembly. The work was conducted under Job #40745 at Colonna's Shipyard's West Yard location, with readings taken by Christopher Kennedy and Noel Layao.
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date Ship & Hull Number CSI REPORT #
3/23/2023 TS FREEDOM STAR 050
Item Title / Subject Required Report Growth / New Work Contract #
Anchor Chain Inspection Yes No Yes No
Description of Conditions Found
KTR inspected and gauged port and starboard anchor chains per ABS. See attached gauging report.
There are 2 ea. damaged links that need to be replaced. One link was deformed with a bend (#5 Shot STBD), & another with a gouge(#3 Shot STBD).
Recommended Repairs
Task KTR to replace bent link with GFM detachable link and remove gouged link from shot completely before reassembly. Pricing to follow.
Material Required: List all models, serials, type, quantities, size, type of material, etc.
1 ea. GFM detachable link.
Colonna’s Representative Print / Sign Name Port Engineer Action/Comments
Originator: J.McClain Shop: 417 Date: 3/23/2023
PM/Superintendent: Gallegos / Johansson Date: 3/23/2023
CSI-FM-005 (REV 01.25.16)
Colonna’s Job #
Spec. Item #/ Work Item #
Item Para Std Item Std Item Para
Colonna’s Work Order #
40745 N/A N/A N/A N/A