SOL_Attach_9_RECOMMENDED QUALITY ASSURANCE PROVISIONS AND SPECIAL INSPECTION REQUIREMENTS.pdf
PDF 370 KB Posted
- Solicitation number
- FA812126R0010
About this file
This document is a collection of AFMC Form 807s (Recommended Quality Assurance Provisions and Special Inspection Requirements) covering fifty-five separate National Stock Numbers (NSNs) related to various aircraft components and parts, primarily for the T56 turbine engine and associated equipment. The forms span from March 2010 through March 2025 and originate from multiple Air Force organizations, including the 538 ACSS, AFLCMC/LPSDBB, AFLCMC/LPSEC2, AFLCMC/LPED2, and AFLCMC/LPSDN.
The quality assurance requirements across these NSNs vary significantly based on item criticality and complexity. Items designated as CAI (Criticality for Aircraft Integrity) or CSI (Criticality for System Integrity) generally require higher-level contract quality requirements, including AS 9100, ISO 9001 (in versions 2000, 2008, or 2015), and NATO AQAP 2070 or equivalent standards. Standard inspection requirements per FAR 52.246-2 through -6 apply to all items, with inspection occurring at source and acceptance at destination. Several items require both standard and higher-level quality requirements simultaneously. Commercial item inspection (FAR 52.212-4) is specified for limited items. All forms include ODS (Ozone Depleting Substances) statements confirming that Class I ODS are not required for contract performance. Quality pre-award surveys are recommended for new sources on selected NSNs. Technical authorities from various AFMC directorates approved these quality requirements, with I&A codes ranging from 1 to 3 and CQR codes including C, G, H, and I designations.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECOMMENDED QUALITY ASSURANCE PROVISIONS
AND SPECIAL INSPECTION REQUIREMENTS
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840013692118OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Welker, Marlon W
ORGANIZATION / SYMBOL
538 ACSS / GFEB
PHONE
405-734-9114 / 884-9114
DATE
03 MAR 2010
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840002250953OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Whitson, Carmela J / 405-582-9753
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
X OTHER (Describe in Block 8)
8. REMARKS
Brannon, Harley JNAME: 27 AUG 2010DATE:
Case and vane assembly; NSN 00-225-0953; P/N 684734.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES X NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
I
11. SIGNATURE OF TECHNICAL AUTHORITY
Brannon, Harley J
ORGANIZATION / SYMBOL
538 ACSS / GFEA
PHONE
405-734-9115 / 884-9115
DATE
27 AUG 2010
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
4320000127080OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wright, Tiffany L / 405-734-4967
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
X OTHER (Describe in Block 8)
8. REMARKS
Brannon, Harley JNAME: 24 AUG 2010DATE:
None.
8a. OZONE DEPLETING SUBSTANCES (ODS)
STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
X WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
I
11. SIGNATURE OF TECHNICAL AUTHORITY
Brannon, Harley J
ORGANIZATION / SYMBOL
538 ACSS / GFEA
PHONE
405-734-9115 / 884-9115
DATE
24 AUG 2010
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840013692119OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCENO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
GOLDIE, PETER A
ORGANIZATION / SYMBOL
538 ACSS / GFEB
PHONE
405-734-4688 / 884-4688
DATE
14 FEB 2012
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
5945008454392OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
X YES X NEW SOURCE
PREVIOUS SOURCENO
X AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
09 APR 2014
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
3040004422945OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Morris, Michael L / 405-734-4963
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
X YES X NEW SOURCE
PREVIOUS SOURCENO
X AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
09 APR 2014
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840014929017OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Prince, Darius V / 405-582-9753
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
23 APR 2014
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
4810011105305OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2915008592915OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840013372608OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Prince, Darius V / 405-582-9753
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840014871830OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Prince, Darius V / 405-582-9753
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840005226376OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Morris, Michael L / 405-734-4963
6. EQUIPMENT SPEC / PHONE
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Vanskike, William P
ORGANIZATION / SYMBOL
AFLCMC / LPSDBB
PHONE
405-734-4966 / 884-4966
DATE
30 JUL 2014
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
5996014064035OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
Spencer, Carl / 405-734-9196
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
X YES X NEW SOURCE
PREVIOUS SOURCENO
X AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Bender, Caleb D
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4603 / 884-4603
DATE
19 JUN 2015
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
5996016284657OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
SPENCER, CARL / 405-734-3159
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Denny, Michael FNAME: 27 JAN 2016DATE:
Item is CAI criticality. NSN is sole source to OEM.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
27 JAN 2016
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840014817439OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wilson, Melissa R / 405-736-2242
6. EQUIPMENT SPEC / PHONE
denny, michael / 405-734-9194
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Denny, Michael FNAME: 18 NOV 2016DATE:
Standard inspection requirements in effect in addition to higher level contract quality requirements
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
18 NOV 2016
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840000218168OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
DENNY, MICHAEL / 405-734-9194
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Denny, Michael FNAME: 17 NOV 2016DATE:
STANDARD INSPECTION REQUIREMENTS IN EFFECT IN ADDITION TO HIGHER LEVEL QUAL REQMTS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
17 NOV 2016
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840016528921OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Prince, Darius V / 405-582-9753
6. EQUIPMENT SPEC / PHONE
DIXON, DAVID P / 405-734-7368
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES X NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
02 MAY 2017
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840016526038OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Prince, Darius V / 405-582-9753
6. EQUIPMENT SPEC / PHONE
DIXON, DAVID P / 405-734-7368
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Denny, Michael FNAME: 02 MAY 2017DATE:
ITEM IS CSI CRITICALITY. RQR-1-T56 APPLIES. STD INSPECTION REQUIREMENTS APPLY IN ADDITION TO HIGHER LEVEL QUAL REQUIREMENTS.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840016563799OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
dixon, david P / 405-734-7368
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
8145009531825OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wilson, Melissa R / 405-736-2242
6. EQUIPMENT SPEC / PHONE
Spencer, Carl / 405-736-3159
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
ISO 9001:2000
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Bender, Caleb DNAME: 10 MAY 2017DATE:
ISO 9001:2015 is latest version. Item P/N is 6848690.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES X NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Bender, Caleb D
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-736-7687 / 336-7687
DATE
10 MAY 2017
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
8145006612972OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wilson, Melissa R / 405-736-2242
6. EQUIPMENT SPEC / PHONE
Bacon, Joseph / 405-734-9195
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
X COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Bragg, Joshua KNAME: 10 MAY 2017DATE:
Completed RDL requested.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
H
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
11 MAY 2017
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
8145014497707OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
Spencer, Carl / 405-736-3159
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Greenfield, Heather LNAME: 10 MAY 2017DATE:
This is a T56 turbine shipping container
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Greenfield, Heather L
ORGANIZATION / SYMBOL
AFLCMC / LPSEC
PHONE
405-739-9173 / 339-9173
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
8145012047393OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wilson, Melissa R / 405-736-2242
6. EQUIPMENT SPEC / PHONE
Spencer, Carl / 405-736-3159
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Greenfield, Heather LNAME: 10 MAY 2017DATE:
This is a T56 compressor module container
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Greenfield, Heather L
ORGANIZATION / SYMBOL
AFLCMC / LPSEC
PHONE
405-739-9173 / 339-9173
DATE
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
8145010103776OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Grissom, Candace R / 405-734-7517
6. EQUIPMENT SPEC / PHONE
SPENCER, CARL / 405-736-3159
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-4696 / 884-4696
DATE
14 JUN 2017
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
4810005283666OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Kalsu, Jon B / 405-736-7117
6. EQUIPMENT SPEC / PHONE
STONE, RAYMOND / 405-734-0543
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Denny, Michael FNAME: 01 APR 2019DATE:
Item is CAI criticality (T56 anti-ice solenoid)
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-9194 / 884-9194
DATE
01 APR 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840004118852OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Jones, Shelia Y / 405-734-4583
6. EQUIPMENT SPEC / PHONE
LeBlanc, Terry / 405-852-1432
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Olson, Gregory TNAME: 15 MAY 2019DATE:
Both standard level inspection and AS 9100 apply.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Olson, Gregory T
ORGANIZATION / SYMBOL
AFLCMC / LPED2
PHONE
405-622-7626 / 892-7626
DATE
15 MAY 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 6Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840006299195OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Jones, Shelia Y / 405-734-4583
6. EQUIPMENT SPEC / PHONE
Olson, Greg / 405-622-7626
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Olson, Gregory TNAME: 11 OCT 2019DATE:
CAI
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Olson, Gregory T
ORGANIZATION / SYMBOL
AFLCMC / LPED2
PHONE
405-622-7626 / 892-7626
DATE
11 OCT 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 3Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840000127100OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Whitson, Carmela J / 405-582-9753
6. EQUIPMENT SPEC / PHONE
STONE, RAYMOND / 405-734-0543
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Denny, Michael FNAME: 18 SEP 2019DATE:
Item has CAI criticality.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-9194 / 884-9194
DATE
18 SEP 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840000127130OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Young, Joseph C / 405-734-7529
6. EQUIPMENT SPEC / PHONE
DENNY, MICHAEL / 405-734-9194
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-9194 / 884-9194
DATE
26 SEP 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 2Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
4320006543617OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Hopkins, Michelle R / 405-996-8855
6. EQUIPMENT SPEC / PHONE
denny, michael / 405-734-9194
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-9194 / 884-9194
DATE
26 SEP 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 3Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
6150008596815OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wilson, Melissa R / 405-736-2242
6. EQUIPMENT SPEC / PHONE
DENNY, MICHAEL / 405-734-9194
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
G
11. SIGNATURE OF TECHNICAL AUTHORITY
Denny, Michael F
ORGANIZATION / SYMBOL
AFLCMC / LPSEC2
PHONE
405-734-9194 / 884-9194
DATE
03 OCT 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 4Generated by PRPS using Jasper Reports on 18 Mar 2025
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2925006275397OJ
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Wilson, Melissa R / 405-736-2242
6. EQUIPMENT SPEC / PHONE
denny, michael / 405-734-9194
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
X HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
AS 9100
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE:…
This is the start of the file's text. The full file is on GovTribe.