Att_19_-_ACA_Facilities.pdf
PDF 248 KB Posted
- Attached to
- Global Security Engineering & Supply Chain
- Solicitation number
- SAQMMA17R0168
About this file
Att 19 - ACA Facilities
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DOS Request for Proposals No. SAQMMA17R0168, Attachment 19
Contractor-Provided Facility Requirements for ACA-Related Activities
Unless otherwise noted, all office space furniture, telephones, tools, equipment and supplies are GFE. The Contractor must provide sufficient facilities, utilities, security, cleaning, and maintenance services to meet or exceed the requirements detailed below.
The Security Systems Integration Division (DS/C/ST/SSI) requires Contractor-provided facilities that meet or exceed the following requirements to integrate protective technologies into DS vehicles:
Combined square footage is 52,100 with 38,000 of that being warehouse space with 20+ ceiling height for the warehouse area. (For movement of tall vehicles/ forklift and storing pallets.)
o Warehouse space requires loading docks and ramps for easy access for receiving and shipping.
o The Contractor is required to provide a forklift and hand trucks to move pallets in the warehouse.
o Warehouse space must accommodate 6 seats with desks, chairs and OpenNet drops for logistical personnel.
Office spaces - 4,320 Sq. Ft. to accommodate 30 seats with desks and chairs and 30 OpenNet drops.
Lab - 25 seats with cabinets with table work space and chairs (approximately 1,800 Sq.
Ft.)
Fabrication cage (900 Sq. Ft.) to accommodate government-owned MIG welder, plasma cutting table, plasma cutting machine, iron worker machine, drill press, metal chop saw, band saw, disk and belt sander, vacuum forming machine. (Hot work permit is required for the fabrication cage).
Eight (8) service bays/stations with easy access for vehicles (electric roll up doors) that accommodate large SUVs (Suburbans). The bays should be big enough to house a DOD MRAP and or DoS Bear (10’ wide X 12’ high X30’ long). The floor must support heavy vehicles up to 10 tons. The facility must accommodate the following government-owned equipment:
o A vehicle exhaust system (for running vehicles in the shop, and for the plasma and welding station in the fabrication cage).
o A heavy duty vehicle lift (20000 pound)
Conference room that accommodates up to 40 people for meetings.
Parking for 35+
DOS Request for Proposals No. SAQMMA17R0168, Attachment 19
SSI also requires the facilities used to configure Security Management System enterprise (SMSe) workstations and servers and high definition video systems (HDVS):
Minimum 3000 Sq. Ft mixed configuration and office space with at least 40 20-Amp circuits (mostly 110volt with 2 – 220volt)
Minimum of 6 OpenNet drops
Easy access to the ground floor entrances for rack movement
Equipment currently in operation in the space:
o 18 SMSe workstations o 1 DL320 (COM016) deployment server. This deployment server is for workstation/server imaging.
o 5 HDVS Servers o 8 HDVS Switches o 2 Palo Alto Firewalls o 1 iSTAR o 16 IP cameras o 5 SMSeNet switches o 4 Raritan IP KVMs o 2 Junipers
Current workload in the space:
o HDVS configurations: currently 3 HDVS builds in place.
o SMSe workstation configurations: shipping 20 configured workstations per month, on average.
SSI also requires Contractor-provided facilities to support the Contingency Communications and
Radio (CCR) program and the System Integration and Monitoring (SIM) program. Facility requirements for CCR are presented in Attachment J-17; SIM requires a minimum of 15,000 Sq.
Ft. of secure indoor, high-bay space for staging and contingency equipment/materials storage.
The Security Infrastructure Directorate (DS/SI) requires Contractor-provided facilities that meet or exceed the following requirements to meet its vital national security responsibilities:
Minimum 500 Sq. Ft. of space for staging and operational use.
Doors capable of receiving and shipping of boxes 36” wide.
Power to operate 15 Dell R730s (or equivalent) simultaneously.
Power to operate 1 Movincool Office Pro36.
3 OpenNet connection drops within this space.
Minimum of 1 phone drop.
Security system to control access and secure space.