S02. Drawings - PLUMBING.pdf
PDF 10 MB Posted
- Attached to
- Expand Primary Care for Pact Realignment Federal contract opportunity
- Solicitation number
- 36C25020B0060_1
About this file
This solicitation is for an expansion project at the Louis Stokes Cleveland VA Medical Center to provide an additional 12,000 square feet of space on three floors for primary care. The contractor shall provide all labor, equipment, supplies and supervision necessary to complete the expansion project, valued between $10-15 million. The project involves expanding primary care for patient aligned care teams. The NAICS code is 236220 for commercial and institutional building construction. The business size standard is $39.5 million. The solicitation number is 36C25020B0060_1. The opportunity is a 100% set-aside for service-disabled veteran-owned small businesses. All bidders must be verified in VETBIZ and registered in SAM by the offer due date and award date. The site visit will be conducted at the medical center and cut-off for requests for information is August 12, 2021. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is the agency listed.
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLBG DEMOLITION GENERAL NOTES
1. THE GENERAL NOTES LISTED HERE APPLY TO ALL DEMOLITION DRAWINGS IN ADDITION TO ANY
ADDITIONAL DEMOLITION DRAWING NOTES ON THE INDIVIDUAL DEMOLITION DRAWINGS.
2. WALLS SHOWN IN DASHED ARE BEING REMOVED. WALLS SHOWN TO BE REMOVED MAY
CONTAIN PLUMBING PIPING TO FIXTURES THAT ARE TO REMAIN. THIS PIPING IS TO BE
PROTECTED DURING WORK.
3. DARK, DASHED LINES INDICATE PIPING AND EQUIPMENT TO BE REMOVED.
4. UNLESS NOTED OTHERWISE, ALL PIPING TO BE DEMOLISHED SHALL BE REMOVED BACK TO THE
MAIN AND CAPPED.
5. CAP ALL REMAINING PIPING WITH SIMILAR MATERIALS. PIPE ENDS INDICATED TO BE CAPPED
ARE NOT TO BE CRIMPED. ALL DCW, DHW, & RDHW PIPING SHOWN TO BE REMOVED AND NOT
INDICATED TO BE EXTENDED WITH NEW WORK, THE CAPPED ENDS ARE TO BE INSULATED WITH
MATERIALS SPECIFIED FOR NEW WORK.
6. NEW INSULATION IS TO BE INSTALLED ON ANY EXPOSED SECTIONS OF PIPING THAT WAS
PREVIOUSLY INSULATED PRIOR TO THE START OF DEMOLITION WORK. THIS INCLUDES CAPPED
ENDS OF PIPING.
7. PROVIDE HANGERS TO SUPPORT ANY REMAINING PIPING OR EQUIPMENT.
8. REMOVE ALL HANGERS AND SUPPORTS FOR PIPING AND EQUIPMENT BEING DEMOLISHED.
9. OWNER SHALL HAVE SALVAGE RIGHTS TO ANY EQUIPMENT OR MATERIALS BEING REMOVED.
ANY EQUIPMENT OR MATERIALS REFUSED BY THE OWNER SHALL BE REMOVED FROM THE SITE.
SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
10. SEE SPECIFICATIONS FOR ALL CUTTING AND PATCHING REQUIREMENTS REQUIRED UNDER
DEMOLITION AND ALSO INDICATED ON DRAWINGS.
11. THIS CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF
CONSTRUCTION.
12. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXACT LOCATION AND
ELEVATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO COMMENCING WORK. THE
PLUMBING CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES WHICH OCCURS BY HIS FAILURE
TO LOCATE OR PRESERVE THE UNDERGROUND CONDITIONS.
13. IF DURING CONSTRUCTION OPERATIONS, THE PLUMBING CONTRACTOR ENCOUNTERS
UTILITIES OTHER THAN THOSE LOCATIONS SHOWN IN THE PLANS, HE SHALL IMMEDIATELY
NOTIFY THE ENGINEER AND TAKE THE NECESSARY STEPS TO PROTECT THE FACILITY AND
ASSURE THE CONTINUANCE OF SERVICE.
14. AN ATTEMPT HAS BEEN MADE TO SHOW ALL ITEMS TO BE REMOVED AND/OR RELOCATED.
FIELD VERIFY EXISTING CONDITIONS INCLUDING LOCATIONS AND INVERTS AND REMOVE OR
RELOCATE ALL PLUMBING PIPING THAT INTERFERES WITH NEW CONSTRUCTION PRIOR TO START
OF WORK.
15. ANY DISRUPTION OF ANY EXISTING SERVICE THAT SERVES THE BUILDING SHALL BE
COORDINATED WITH THE OWNER PRIOR TO DISRUPTION. WORK ASSOCIATED WITH THIS
SERVICE SHALL BE PERFORMED AT A TIME REQUESTED BY OWNER WHICH COULD BE
PERFORMED OFF STANDARD WORKING HOURS AT NO ADDITIONAL COST TO OWNER FOR TIME OF
WORK. COST TO BE INCLUDED UNDER BASE BID FOR PROJECT.
16. ALL CONTRACTORS SHALL COORDINATE THEIR WORK WITH OTHER CONTRACTORS AND WITH
THE OWNER. THIS INCLUDES ALL SHUTDOWNS AND DRAINING REQUIRED. THIS CONTRACTOR TO
COORDINATE PLUMBING SYSTEM SHUTDOWNS WITH THE OWNER AT LEAST 24 HOURS PRIOR TO
THE BEGINNING OF THE SHUTDOWN.
17. THE PLUMBING CONTRACTOR IS TO MINIMIZE THE AMOUNT OF CEILING, CHASE, AND WALL
REMOVAL FOR THE REMOVAL AND REPLACEMENT OF SANITARY, VENT, DCW, AND DHW LINES
SERVING THE PLUMBING FIXTURES. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR
PATCHING THE CEILING, CHASE, AND WALLS TO MATCH EXISTING CONDITIONS. REMOVAL OF
SANITARY AND WATER PIPING IS TO BE COORDINATED WITH THE NEW WORK PLANS AND THE
OWNER TO MINIMIZE DISTURBANCE.
18. WHERE PLUMBING PIPING HAS BEEN REMOVED AND/OR CAPPED, THE PLUMBING
CONTRACTOR IS TO PATCH FLOOR/WALL TO MATCH EXISTING CONDITIONS.
19. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR CUTTING AND PATCHING OF EXISTING
WALLS AND CEILINGS THAT REQUIRES PLUMBING WORK AND IS OUTSIDE THIS PROJECT.
PATCHING IS TO MATCH EXISTING CONSTRUCTION AND FINISH.
20. REMOVAL AND REINSTALLATION OF CEILINGS NOT INDICATED TO BE REMOVED AND
REINSTALLED ON THE ARCHITECTURAL DRAWINGS TO BE PERFORMED BY THIS CONTRACTOR
FOR DEMOLITION OR INSTALLATION OF NEW PIPING OR EQUIPMENT OUTSIDE THE PROJECT
AREA. REMOVAL OF PLUMBING PIPING IN CEILING SPACE IS TO BE COORDINATED WITH THE NEW
WORK PLAN TO MINIMIZE DISTURBANCE TO ADJACENT SPACES.
21. THE PLUMBING CONTRACTOR SHALL REMOVE PLUMBING PIPING IN WALLS TO BE REMOVED
AND RE-PIPE ALL ITEMS OUTSIDE THE DEMOLITION LIMITS AND RESTORE TO ORIGINAL WORKING
CONDITION.
PLUMBING GENERAL NOTES
1. THE GENERAL NOTES LISTED HERE APPLY TO ALL PLUMBING DRAWINGS IN ADDITION TO ANY
ADDITIONAL DRAWING NOTES ON THE INDIVIDUAL DRAWINGS.
2. SEE CODED NOTES ON INDIVIDUAL DRAWING SHEETS FOR SPECIFIC INSTRUCTIONAL NOTES.
3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION.
4. IF DURING CONSTRUCTION OPERATIONS, THE PLUMBING CONTRACTOR ENCOUNTERS
UTILITIES OTHER THAN THOSE LOCATIONS SHOWN IN THE PLANS, HE SHALL IMMEDIATELY
NOTIFY THE ENGINEER AND TAKE THE NECESSARY STEPS TO PROTECT THE FACILITY AND
ASSURE THE CONTINUANCE OF SERVICE.
5. COORDINATE WITH GENERAL TRADES WORK, HVAC WORK, FIRE PROTECTION WORK,
ELECTRICAL WORK AND OTHER WORK.
6. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE AND SMOKE WALLS AND RATED
STRUCTURES. SEE DETAILS AND SPECIFICATIONS FOR PIPE PENETRATION SEAL
REQUIREMENTS.
7. THE PLUMBING DESIGN DRAWINGS ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW
EXACT LOCATION OF EQUIPMENT AND PIPING UNLESS DIMENSIONS ARE GIVEN OR OTHERWISE
IMPLIED FOR CLEARANCES, ETC. PIPING AND PLUMBING EQUIPMENT ARE TO BE INSTALLED
ALONG THE GENERAL PLANS SHOWN ON THE DRAWINGS, BUT KEEPING IN MIND ACTUAL
BUILDING CONDITIONS WHICH MUST BE CONFORMED WITH IN THE ACTUAL WORK. CONTRACTORS
IN THEIR BIDS ARE REQUIRED TO INCLUDE ALL LABOR AND MATERIALS AND OTHER RELATED
WORK NECESSARY TO PROVIDE MINOR OFFSETS IN PLUMBING WORK AS REQUIRED TO AVOID
CONFLICT WITH OTHER WORK ON THIS PROJECT OR AS REQUIRED IN ORDER TO OBTAIN
MAXIMUM HEAD ROOM OR EQUIPMENT ACCESS IN SPACES.
8. THE PLUMBING CONTRACTOR IS TO COORDINATE ALL PIPING WITH OTHER TRADES PRIOR TO
ROUTING PIPING AND SHALL MAKE OFFSETS AND ADJUST PIPE ROUTING AS REQUIRED TO
HANDLE CONFLICTS IN FIELD. THE PLUMBING CONTRACTOR SHALL ALSO BE REQUIRED TO
OFFSET VERTICAL SANITARY AND VENT LINES AROUND STRUCTURAL MEMBERS AS REQUIRED
AND SHALL INCLUDE IN THEIR BASE BID THE ASSOCIATED COST FOR ADDITIONAL FITTINGS,
PIPING, AND MAN HOURS TO ACCOMMODATE CONFLICTS.
9. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION AND ELEVATION OF PLUMBING FIXTURES.
10. ALL COLD WATER AND HOT WATER PIPING TO INDIVIDUAL SINKS AND INDIVIDUAL LAVATORIES
TO BE 1/2", UNLESS OTHERWISE INDICATED.
11. ALL COLD WATER AND HOT WATER PIPING SERVING 3 OR LESS SINKS OR LAVS ARE TO BE 3/4"
UNLESS NOTED OTHERWISE.
12. FINAL COLD WATER PIPING CONNECTIONS TO WATER CLOSETS TO BE 1-1/4".
13. UNLESS OTHERWISE NOTED SEE PLUMBING FIXTURE SCHEDULE FOR FIXTURE DRAIN, VENT, DCW AND DHW PIPE SIZES.
14. P.C. TO FURNISH WALL FLANGES AROUND ALL PIPING EXPOSED BELOW CEILING AND
CASEWORK.
15. P.C. TO COORDINATE ALL COUNTERTOP SINKS WITH CASEWORK TO ENSURE PROPER
INSTALLATION AND CLEARANCE REQUIREMENTS PRIOR TO ORDERING AND INSTALLATION.
COORDINATE ANY CHANGE IN SIZE OR CONFIGURATION WITH PROJECT ENGINEER AND
ARCHITECT.
16. SEE PLUMBING ISOMETRICS FOR SANITARY PIPE SIZES NOT INDICATED ON FLOOR PLANS.
17. UNLESS OTHERWISE INDICATED, ALL PIPING TO RUN GENERALLY BELOW DUCTWORK FOR
ACCESS TO VALVING. DO NOT OBSTRUCT EQUIPMENT OR ACCESS DOORS.
18. DRAIN VALVES WITH HOSE ADAPTORS ARE TO BE INSTALLED AT THE BASE OF ALL DCW, DHW, AND RDHW RISERS.
19. EQUIPMENT CONNECTION ARRANGEMENTS, FLANGES, UNIONS, VALVING, ETC. ARE NOT
TYPICALLY SHOWN ON PLAN VIEWS. REFER TO DETAILS AND FLOW DIAGRAMS FOR
REQUIREMENTS. INSTALL ALL VALVES AND OTHER ITEMS REQUIRING OR FACILITATING
MAINTENANCE IN ACCESSIBLE LOCATIONS, AND SO AS TO NOT OBSTRUCT MAINTENANCE ON
EQUIPMENT SERVED.
20. SEE PROJECT SPECIFICATIONS FOR CUTTING AND PATCHING RESPONSIBILITIES.
21. FINAL FLOOR DRAIN ELEVATIONS ARE TO BE SET BY THE PLUMBING CONTRACTOR.
COORDINATE EXACT POSITIONING OF FLOOR DRAINS WITH HVAC CONTRACTOR TO SERVE HVAC
EQUIPMENT AS INTENDED, AND TO AVOID TRIPPING HAZARDS WITH ABOVE FLOOR DRAIN PIPING.
22. PLUMBING FIXTURE NUMBERS ARE SHOWN ON WASTE PLANS AND REFERS TO PLUMBING
FIXTURE SCHEDULE.
23. ACCESS PANELS ARE TO BE FURNISHED AND INSTALLED BY THE PLUMBING CONTRACTOR.
THE PLUMBING CONTRACTOR IS TO COORDINATE LOCATION AND INSTALLATION OF VALVES,
SHOCK STOPS, AND CLEANOUTS ABOVE ACCESS PANEL WITH G.C. AND ARCHITECTURAL
DRAWINGS TO MINIMZE SIZE OF PANELS.
24. SEAL ALL PIPING PENETRATIONS THROUGH NON-RATED FLOORS TO PREVENT PASSAGE OF
SMOKE.
WALL SECTION
FLOOR SECTION
FURNISH AND INSTALL
FIRESTOP MATERIALS IN
ACCORDANCE WITH
APPROPRIATE U.L. SYSTEMS
TO MAINTAIN FIRE RESISTANCE
RATING
PIPE SLEEVE
DAMMING MATERIAL
(PER U.L. TESTED
SYSTEM DESIGN)
FLOOR SLAB; SEE
ARCHITECTURAL DRAWINGS
FOR FLOOR CONSTRUCTION
AND FIRE RATING
PIPE INSULATION
(WHERE SPECIFIED)
PENETRATING COMPONENT
FURNISH AND INSTALL FIRESTOP
MATERIALS IN ACCORDANCE WITH
APPROPRIATE U.L. SYSTEMS TO
MAINTAIN FIRE RESISTANCE RATING
PIPE SLEEVE (SLEEVE TO
EXTEND 2" ABOVE FLOOR
IN MECHANICAL EQUIPMENT
ROOMS.)
SEAL JOINT BETWEEN SLEEVE
AND FLOOR SLAB WITH MIN. 1/2"
BEAD FIRESTOP CAULK
SEE ARCHITECTURAL
DRAWINGS FOR WALL
CONSTRUCTION AND FIRE
RATING
PENETRATING COMPONENT
PIPE INSULATION
(WHERE SPECIFIED)
NOTES:
1. WHERE PIPES, DUCTS AND OTHER COMPONENTS PASS THROUGH FIRE OR SMOKE RATED WALLS OR FLOORS, PROVIDE NON-ASBESTOS SEAL ASSEMBLIES CLASSIFIED BY U.L. TO PROVIDE FIRE BARRIERS EQUAL TO OR GREATER THAN THE TIME RATING OF THE CONSTRUCTION BEING PENETRATED, WITH APPROPRIATE MATERIALS AND SYSTEMS THAT COMPLY WITH APPLICABLE CODES AND THAT HAVE BEEN
TESTED IN ACCORDANCE WITH U.L. 1479 OR ASTM E814.
2. GROUT, MORTAR OR GYPSUM BASED PRODUCTS SHALL NOT BE INSTALLED IN LIEU OF FIRESTOPPING
MATERIALS AND U.L. SYSTEMS.
3. FOR SLEEVED PENETRATIONS, FIRESTOP ANNULAR SPACE, IF ANY, BETWEEN SLEEVE AND ADJACENT
CONSTRUCTION TO MEET U.L. SYSTEM REQUIREMENTS. SEE NOTE 2 ABOVE.
4. THIS CONTRACTOR SHALL FIRESTOP ALL MISCELLANEOUS OPENINGS IN FIRE-RATED CONSTRUCTION
RESULTING FROM HIS WORK.
5. CONTRACTOR SHALL PROVIDE SUBMITTAL DRAWINGS TO ARCHITECT, INCLUDING U.L. RATED SYSTEM
NUMBER AND DETAIL FOR EACH TYPE OF PENETRATION AND CONFIGURATION.
6. THE FIRESTOPPING SYSTEMS ARE TO BE INSTALLED BY EXPERIENCED, MANUFACTURER TRAINED, AND
UL CERTIFIED OR FM CERTIFIED PERSONNEL.
7. ALL FIRESTOPPING MATERIAL IS TO BE PROVIDED FROM A SINGLE MANUFACTURER FOR ALL
APPLICATIONS.
8. CONTRACTOR SHALL CONSULT MANUFACTURER'S TECHNICAL EXPERTS FOR ASSISTANCE IN SELECTING
APPROPRIATE FIRESTOPPING SYSTEM FOR EACH APPLICATION.
THROUGH FIRE-RATED CONSTRUCTIONS
N.T.S.
FIRESTOPPING DETAIL FOR PENETRATIONS
DESCRIPTIONABBREVIATION SYMBOL
US
SAN
UST
DS
PD
DCW
DHW
RDHW
MA
O
MV
F.P.S.C.
H.B.
F.D.
R.D.
A.D.
PLUMBING SYMBOL LEGEND
US SANITARY SEWER BELOW FLOOR OR GRADE
SAN SANITARY SEWER ABOVE FLOOR
SANITARY VENT
UST STORM SEWER BELOW FLOOR OR GRADE
DS DOWNSPOUT ABOVE FLOOR (WITHIN BUILDING SPACE)
PD PUMP DISCHARGE
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
RDHW RECIRCULATED DOMESTIC HOT WATER
MA MEDICAL COMPRESSED AIR
O OXYGEN
MV MEDICAL VACUUM
SHOCK STOP IN HORIZONTAL
GATE VALVE
GAS COCK
GLOBE VALVE
BALL VALVE
BALANCE VALVE (SEE SPECIFICATIONS)
CHECK VALVE (SWING)
PUMP DISCHARGE SILENT LIFT CHECK VALVE
CONCENTRIC REDUCER/INCREASER
STRAINER WITH BLOWDOWN
UNION
FLANGED UNION
EXPANSION JOINT
PIPE ANCHOR
PIPE GUIDE
PIPE SLEEVE (SEE SPECIFICATIONS FOR ADDIT. REQUIREMENTS)
VIBRATION CONNECTION (SEE SPECIFICATIONS)
PETE'S TEST PLUG
MANUAL AIR VENT
AUTOMATIC AIR VENT WITH BALL VALVE
BFP DOUBLE CHECK BACKFLOW PREVENTER
RPBP REDUCED PRESSURE BACKFLOW PREVENTER WITH AIR GAP DEVICE AND DRAIN
COMPANION FLANGE
YARD HYDRANT
C.O. CLEANOUT
FW/FCO FLUSH WITH FLOOR CLEANOUT
FW/WCO FLUSH WITH WALL CLEANOUT
F.P.S.C. FROSTPROOF SILL COCK / WALL HYDRANT
FAUCET OR HOSE BIBB
F.D. SANITARY FLOOR DRAIN
R.D. ROOF DRAIN
A.D. AREA DRAIN (STORM)
D.S. D.S. DOWNSPOUT
R.L. R.L. RAIN LEADER
PRESSURE GAUGE WITH GAUGE COCK (WATER)
PRESSURE GAUGE WITH BALL VALVE (WATER)
P__-__ PLUMBING FIXTURE (SEE SCHEDULE)
PE__-__ PLUMBING EQUIPMENT (SEE SCHEDULE)
E.C. E.C. ELECTRICAL CONTRACTOR
F.P.C. F.P.C. FIRE PROTECTION CONTRACTOR
G.C. G.C. GENERAL CONTRACTOR
H.C. H.C. HVAC CONTRACTOR
P.C. P.C. PLUMBING CONTRACTOR
A.D. A.D. ACCESS DOOR
A.F.F. A.F.F. ABOVE FINISHED FLOOR
F.F.E. F.F.E. FINISHED FLOOR ELEVATION
MFR. MFR. MANUFACTURER
N.O. N.O. NORMALLY OPEN
N.C. N.C. NORMALLY OPEN
TYP. TYP. TYPICAL
INDICATES TIE INTO EXISTING
INDICATES REMOVE TO POINT FOR RECONNECTION
INDICATES REMOVE TO POINT AND CAP
CLEVIS HANGER PIPE SUPPORT
N.T.S.
NOTE:
REFER TO HANGER SPECIFICATIONS
FOR ADDITIONAL REQUIREMENTS.
PIPE ℄
TYPICAL FOR
UN-INSULATED PIPE
TYPICAL FOR
INSULATED PIPE
STRUCTURAL FRAMING
NOTE: SUPPLY ADDITIONAL
SUPPORT STEEL AS
REQUIRED
BEAM CLAMP
HEX NUTS (4 REQUIRED)
THREADED ROD (SEE
SPECIFICATIONS FOR DIAMETER)
ADJUSTABLE CLEVIS HANGER
PIPE WITH INSULATION AND
JACKET (AS APPLICABLE).
SEE SPECIFICATIONS FOR
REQUIREMENTS.
180 DEG. INSULATION PROTECTION
SHIELD, 14 GA., GALVANIZED BY 18"
LONG FOR PIPING 8" AND OVER.
SEE SPECIFICATIONS FOR 6" AND
UNDER.
SUPPORT BLOCK (SEE
SPECIFICATIONS)
BUILDING DRAIN CLEANOUT DETAIL
N.T.S.
"Y" BRANCH
FINISHED GRADE
ADJUSTABLE HOUSING
6" C.I. ENCASED IN IN CONCRETE
6" THICK ON EACH SIDE OF PIPE
6" C.I.
P.C. TO COORDINATE WITH ROOM FINISH SCHEDULE
AND PLUMBING FIXTURE SCHEDULE, PROVIDE
CARPET MARKERS WHERE APPLICABLE.
COORDINATE LOCATIONS WITH CARPET INSTALLER.
P.C. TO FURNISH COVER LIDS TO MATCH TYPE OF
FLOOR FINISH.
M A
X
VENT PIPE CURB DETAIL
N.T.S.
STORM COLLAR CLAMP
TO PIPE
SILICONE CAULK
ROOF LINE
ROOF INSULATION
ROOFING, MEMBRANE, RUN
UP UNDER COVER (BY G.C.)
PIPE - SEE PLANS FOR QUANTITY
SIZES, ARRANGEMENT, AND
CONTINUATION
ANCHOR TO EXISTING ROOF
DECK AS REQUIRED
"PATE" TYPE PCA-5
CURB ASSEMBLY
GALVANIZED STEEL COVER
SECURE TO CURB
STAINLESS STEEL CLAMP
VENT TERMINATION HEIGHT IN
ACCORDANCE WITH LOCAL
JURISDICTION.
TYPICAL ROOF DRAIN DETAIL
N.T.S.
SEE DRAWINGS FOR SIZES
UNDERDECK CLAMP
P.C. TO INSTALL ALL
NECESSARY SUPPORT
BRACING PLATE AROUND
OPENING AS REQUIRED
TO INSTALL ROOF DRAIN.
FLASHING AND COUNTER FLASHING
BY ROOFING CONTRACTOR. P.C. TO
COORDINATE AND SECURE ROOFING
MEMBRANE TO ROOF DRAIN.
ROOF MEMBRANE
INSULATION
CONCRETE DECK
INSULATE ALL VERTICAL AND
HORIZONTAL SECTIONS OF
DOWNSPOUT, SEE
DOWNSPOUT DETAIL
CHECK VALVE (TYP.)
BALANCE VALVE (TYP.) PRESSURE GAUGE (TYP.)
H.W. RECIRCULATING PUMP,
SEE PLUMBING EQUIPMENT
SCHEDULE.
PE-2
RECIRCULATING HOT WATER PUMP DETAIL
N.T.S.
RDHW
RDHW TO HOT WATER
HEATERS
FROM NEW
ADDITION
FROM EXISTING
BUILDING
NOTE:
1. PROVIDE FLUSHING TAPS, DISINFECTION, AND TESTING FOR EACH DOMESTIC WATER SYSTEM: DOMESTIC COLD WATER, DOMESTIC HOT WATER, DOMESTIC HOT WATER RETURN.
2. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT REQUIRED TO COMPLETE DISINFECTION AND TESTING PER THE PROCEDURE LISTED BELOW THIS WILL INCLUDE BUT NOT BE LIMITED TOO THE FOLLOWING; BACKFLOW PREVENTER, TEMPORARY PUMPS, CONNECTION/DRAIN HOSES, CHLORINE, BARRELS AND TESTING EQUIPMENT.
SEQUENCE OF OPERATIONS:
1. DOMESTIC WATER PIPE SHALL BE FLUSHED AND DISINFECTED PRIOR TO CONNECTING TO HOSPITAL POTABLE WATER SYSTEMS, AND BEFORE ACCEPTANCE BY THE VA. CONTRACTOR SHALL SCHEDULE TEST WITH VA AND DOCUMENT DISINFECTION WITH A WITNESSED REPORT. A. INSTALL ISOLATION VALVES AND INJECTION TEES ON THE HOT, COLD AND HOT WATER RETURN LINES SO ALL FIXTURES INSTALLED IN THE SCOPE OF THE PROJECT CAN BE DISINFECTED (SHOCK CHLORINATED). INSURE ISOLATION VALVES ARE INSTALLED TO PROHIBIT DISINFECTION CHEMICALS FROM ENTERING BACK
INTO THE MEDICAL CENTER DOMESTIC WATER LINES.
A. REMOVE ALL LAMINAR FLOW DEVICES AND OR SCREENS AND COMPLETELY FLUSH ALL FIXTURES AT FULL VOLUME FOR
10 MINUTES. SOURCE WATER SHALL HAVE A BACKFLOW PROTECTION DEVICE.
B. DISINFECTION SHALL BE ACCOMPLISHED THRU SHOCK CHLORINATION WITH ONE OF FOLLOWING TWO METHODS:
1. FILL PIPING SYSTEM WITH A WATER/CHLORINE MIXTURE LEVEL OF AT LEAST 50 PPM FREE CHLORINE FOR A MINIMUM OF 24 HOURS. ALL FIXTURES SHOULD HAVE 50 PPM AT THE TAP. (STRONG SMELL OF CHLORINE AT THE FAUCET).
2. FILL PIPING SYSTEM WITH A WATER/CHLORINE MIXTURE LEVEL OF AT LEAST 200 PPM FREE CHLORINE FOR A MINIMUM OF 3 HOURS AND A MAXIMUM OF 4 HOURS. ALL FIXTURES SHOULD HAVE 200 PPM AT THE TAP. (STRONG SMELL OF
CHLORINE AT THE FAUCET).
D. AFTER DISINFECTION ALL FIXTURES MUST BE FLUSHED AND TESTED TO INSURE SAFE POTABLE WATER LEVELS ARE
AVAILABLE. NO MORE THAN 3 PPM FREE CHLORINE.
E. TWO TEST SAMPLES SHALL BE TAKEN 24 HOURS APART FROM EACH OF THE FOLLOWING LOCATIONS; BEGINNING OF MAIN, END OF MAIN, AND EACH BRANCH. WATER SHALL BE TESTED FOR FREE CHLORINE (LESS THAN 3 PPM) AND COLIFORM
ORGANISMS (NONE PRESENT).
F. SUBMIT REPORT WHICH DOCUMENTS ABOVE TEST AND PROCEDURE. RESULT SHALL BE WITNESSED AND SIGNED OFF BY
VA REPRESENTATIVE.
CONNECTION POINT TO EXISTING
DOMESTIC COLD WATER SYSTEM WITHIN 2 PIPE
DIAMETERS MAIN BRANCH TO NEW
PLUMBING FIXTURES
EXISTING DOMESTIC
WATER SYSTEM
ISOLATION VALVE
WITHIN 2 PIPE
DIAMETERS
3/4" BALL VALVE WITH MALE
HOSE THREADS AND CAP
DOMESTIC WATER DISINFECTING/FLUSHING PROCEDURE
N.T.S.
3" SUMP VENT, SEE FLOOR
PLAN FOR CONTINUATION
WIRING BY E.C.
CONTROL PANEL FURNISHED
AND INSTALLED BY P.C.
COORDINATE WIRING TO
BAS WITH T.C.C. SEE
SPECIFICATIONS.
HIGH LEVEL ALARM
INDICATOR
CONTROL WIRING ACCESS
CONDUIT
SUMP PUMP ACCESS
AND REMOVAL COVER
MOUNT CONTROL PANEL
ON NEAREST WALL
PLAN VIEW
ELEVATION
4" THICK CONCRETE PAD
36" x 60" DEEP
POLYETHYLENE
BASIN
FLOOR
BASIN LID
3" SUMP VENT
CLEANOUT
BALL VALVE
PUMP DISCHARGE
CHECK VALVE
UNION
PUMP ACCESS COVER
PUMP OFF
PUMP #1 ON
PUMP #2 ON
HIGH LEVEL ALARM
UNION
PUMP DISCHARGE
PUMP PULL ROD/CABLE
ASSEMBLY
DUPLEX SUMP PUMP DETAIL
N.T.S.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:1
PM
P-001
PLUMBING GENERAL NOTES, SCHEDULES,
DETAILS, AND SYMBOL LEGEND
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
NOTES:
PLUMBING EQUIPMENT SCHEDULE
MARK. NO. DESCRIPTION MAKE/MODEL/SIZE REMARKS
PE-1 DUPLEX FOUNDATION
SUMP PUMPS AND BASIN
"CRANE/BARNES"
MODEL SE1044L
(2) PUMPS RATED FOR 43 GPM AT 30 TDH. 1 HP 208V/3 PHASE. PROVIDE 36" DIA. x 60"
DEEP POLYETHYLENE BASIN. PROVIDE WITH NEMA 1 DUPLEX CONTROL PANEL.
CONTROL PANEL TO INCLUDE HOA SWITCH FOR EACH PUMP, ALARM AUXILIARY DRY
CONTACT, AND (4) LEVEL FLOAT SWITCHES WITH 20' CORDS. PROVIDE PUMPS WITH 25'
CORDS.
PE-2 INLINE RECIRCULATING
HOT WATER PUMP
"TACO"
MODEL 113
INLINE PUMP CAPACITY TO BE 10 GPM WITH 15 FEET OF HEAD. MOTOR RPM OF 1725,
1/8" HP MOTOR, 120 VOLT/1 PHASE, AND 1" PUMP CONNECTIONS. E.C. TO PROVIDE
MOTOR STARTER AND DISCONNECT SWITCH. SEE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
NOTES:
PLUMBING FIXTURE CONNECTION SCHEDULE
MARK NO. FIXTURE DRAINAGE WATER
W.P. V.P. CW HW
A.D. AREA DRAIN
F.D. FLOOR DRAIN
P-103 WATER CLOSET
WALL HUNG
4" 2" 1-1/2" -
P-413 LAVATORY
COUNTERTOP
1-1/2" 1-1/2" 1/2" 1/2"
P-414 LAVATORY
WALL HUNG
1-1/2" 1-1/2" 1/2" 1/2"
P-502 MOP SINK 3" 1-1/2" 1/2" 1/2"
P-528 STAINLESS STEEL
DROP-IN SINK
1-1/2" 1-1/2" 1/2" 1/2"
P-529 STAINLESS STEEL
UNDERMOUNT SINK
1-1/2" 1-1/2" 1/2" 1/2"
P-801 FROST PROOF WALL
HYDRANT
- - 3/4" -
P-804 WALL HYDRANT - - 3/4" -
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19 100% CD's SUBMISSION 2.14.20
BID ISSUE SUBMISSION 8.1.21
49 50 50.3 51 52 53
J
K
K4
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
8" S
AN
8" SAN
8" S
AN
8"
S
AN
8" SAN
" U
ST
" U
ST
" U
ST
8" S
AN
2 1/2" DCW
2 1/2" DHW
1 1/4" RDHW
8" S
AN
8"
S
AN
3/ 4"
D C
W
2" D
C W
2"
4" SAN
2"
4" 4"
4"
4" SAN
4"
4"
3" D
C W
2" D
H W
1" R
D H
W
3" DCW
2" DHW
1" RDHW
" U
ST
8" S
AN
3" D
C W
2" D
H W
1" R
D H
W
2" D
C W
UST
5 6
OUTPATIENT PHARMACY
CODED NOTES
1. REMOVE EXISTING 8" US PIPING BETWEEN POINTS INDICATED FOR RECONNECTION UNDER
PHASE 1 NEW WORK.
2. REMOVE EXISTING DCW, DHW AND RDHW PIPING BETWEEN POINTS INDICATED FOR
RECONNECTION UNDER PHASE 1 NEW WORK.
3. REMOVE SECTION OF EXISTING FOOTER DRAINAGE PIPING. COORDINATE EXTENT OF
REMOVAL WITH NEW WORK PLAN.
4. REMOVE EXISTING 4" SAN BACK TO POINT INDICATED AND CAP.
5. EXISTING 4" SAN AND 3" VENT STACKS TO REMAIN.
6. EXISTING 6" STORM STACK TO REMAIN.
7. EXISTING 3" DCW, 2" DHW AND 1" RDHW RISERS TO REMAIN.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
C. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:0
PM
P-D-0-1
BASEMENT LEVEL PHASE I PLUMBING
DEMOLITION PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
BASEMENT LEVEL PHASE I PLUMBING DEMOLITION PLAN
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
FEC
FE
C
FEC
REF
49 50 50.3 51 52 53
J
K
K4
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
5 6
CODED NOTES
1. REMOVE EXISTING PLUMBING FIXTURES ALONG WITH ALL ASSOCIATED DOMESTIC WATER,
SANITARY AND VENT PIPING, AND VALVING TO POINTS INDICATED AND CAP.
2. REMOVE EXISTING HOSE BIBB AND ALL ASSOCIATED PIPING AND VALVING BACK TO BELOW
FLOOR AND CAP.
3. REMOVE EXISTING 1-1/2" VENT BACK TO POINT INDICATED AND CAP.
4. REMOVE EXISTING FLOOR DRAIN.
5. EXISTING 4" SAN AND 3" VENT STACKS TO REMAIN.
6. EXISTING 6" STORM STACK TO REMAIN.
7. EXISTING 3" DCW, 2" DHW AND 1" RDHW RISERS TO REMAIN.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
C. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:3
PM
P-D-1-1
FIRST FLOOR LEVEL PHASE I PLUMBING
DEMOLITION PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
FIRST FLOOR LEVEL PHASE I PLUMBING DEMOLITION PLAN
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
C
FE
C
49 50 50.3 51 52 53
J
K
K4
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
3/ 4"
D C
W 3/
4" D
H W
1/ 2"
R D
H W
2" DCW
1 1/4" DHW
1/2" RDHW
1/2" O
3/4" MV
1/2" MA
1" DCW
1/2" O
3/4" MV
1/2" MA
1" DHW
1/2" RDHW
2" D
C W
1" D
H W
1/ 2"
R D
H W
2" D
C W
1" D
H W
1/ 2"
R D
H W
1 1/2" DCW
1" DHW
1/2"
1/
2" D
C W
1/
2" D
H W
3/ 4"
R D
H W
3/ 4"
D C
W 3/
4" D
H W
1/ 2"
R D
H W
1/2" O
3/4" MV
1/2" MA
2" D
C W
1" D
H W
1/ 2"
R D
H W
2" D
C W
1/ 2"
M A
1/
4" M
V 3/
4" O
CODED NOTES
1. EXISTING 2-1/2" DCW, 2" DHW AND 1" RDHW PIPE RISERS DOWN TO FIRST FLOOR TO REMAIN.
2. REMOVE MEDICAL GAS OUTLETS AND MEDICAL GAS PIPING BACK TO POINTS INDICATED AND
CAP.
3. REMOVE EXISTING SINK AND ALL ASSOCIATED PIPING BACK TO MAINS AND CAP.
4. EXISTING 3/4" O, 1-1/4" MV AND 3/4" MA PIPE RISERS DOWN TO FIRST FLOOR TO REMAIN.
5. EXISTING 4" SAN AND 3" VENT STACKS TO REMAIN.
6. EXISTING 6" STORM STACK TO REMAIN.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
C. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:2
PM
P-D-2-1
SECOND FLOOR LEVEL PHASE I PLUMBING
DEMOLITION PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
SECOND FLOOR LEVEL PHASE I PLUMBING DEMOLITION PLAN
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
K
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
TO EXISTING
HOT WATER
HEATERS
2 1/2" DCW
2 1/2" DHW
1 1/4" RDHW
3" DCW
2" DHW
1" RDHW
3" D
C W
2" D
H W
1" R
D H
W
2" D
C W
3/ 4"
D C
W1
2 1/2" DCW
2" DHW
1" RDHW
2" D
C W
PE-2
OUTPATIENT PHARMACY
BAC318 BAC317
BAC316
BS1 BAC309
BAC308
BAC307
BA109A
BA111-1
BS5-1BA109
BA109C
BS3
BAC306
BAC303
BAC302
BAC301A
BAC301BAC312BAC313
BAC311
BAC330
BAC285
BAC281
BAC282
BAC280
BAC283 BAC253
BAC260B
BAC252 BAC251
BAC250
BAC256
BAC257
BAC258
BAC259
BAC255BAC254
BAC286BAC329
BAC326
BAC325
BAC327
BAC250B
BAC328
BA110-1
3/4" DCW
3/ 4"
D C
W
P-804
CODED NOTES
1. EXISTING 3" DCW, 2" DHW AND 1" RDHW PIPE RISERS UP.
2. TIE NEW 2-1/2" DCW, 2" DHW AND 1" RDHW PIPING INTO EXISTING 2-1/2" DCW, 2-1/2" DHW AND
1-1/4" RDHW.
3. INSTALL 2-1/2" DCW, 2" DHW AND 1" RDHW PIPE RISERS UP IN WALL.
4. INSTALL NEW DOMESTIC HOT WATER RECIRCULATION PUMP. SEE DETAIL FOR ADDITIONAL
REQUIREMENTS.
5. HEAVY DASHED BOUNDARY INDICATES OUTPATIENT PHARMACY. REFER TO ARCHITECTURAL
PLAN AS-0.1 FOR SPECIAL TIMEFRAME AND INFECTION CONTROL REQUIREMENTS AND STAFFING RESTRICTIONS THAT MUST BE STRICTLY ADHERED TO. COORDINATE CONSTRUCTION ACITVITIES
WITH VA COR AHEAD OF TIME TO ENSURE ALL PROTECTIVE MEASURES ARE IN PLACE.
6. INSTALL 3/4" DCW LINE DOWN ALONG COLUMN TO HOSE BIBB WITH VACUUM BREAKER
MOUNTED AT 36" ABOVE FINISHED FLOOR.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:2
PM
P-0.1-1
BASEMENT LEVEL PHASE I PLUMBING PIPING
IMPROVEMENT PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
BASEMENT LEVEL PHASE I PLUMBING PIPING IMPROVEMENT PLAN
ROOM LEGEND
BA109 Mechanical Room
BA109A Areawell Access BA109C Office BA110-1 Outside Air Enclosure-1 BA111-1 Mechanical Room-1 BAC250 Waiting
BAC250B Passage BAC251 Triage BAC252 Exam BAC253 Exam BAC254 Exam BAC255 Exam BAC256 Records BAC257 Office BAC258 Soiled Holding BAC259 Clean Supply
BAC260B Passage BAC280 Anti-Coagulation Clinic Open Office BAC281 Office BAC282 Copy File/Work BAC283 Break Room BAC285 Storage, File Room BAC286 Conference Room BAC301 Storage
BAC301A HD Storage Room
BAC302 HAC
BAC303 Staff Lockers/Break BAC306 Office BAC307 Work Room BAC308 Comm BAC309 Electrical Closet BAC311 Outpatient Pharmacy BAC312 Tech Sup. Mail Order BAC313 Consult Room BAC316 Supervisor BAC317 Tech Supply BAC318 Controlled Sub,/ Sec Disp BAC325 Elevator Lobby BAC326 Waiting BAC327 Corridor BAC328 Corridor BAC329 Womens BAC330 Mens
BS1 Stair 1 BS3 Stair 3
BS5-1 Stair 5-1
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
K
K4
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
8" S
AN
" U
ST
8" S
AN
" U
ST
8" S
AN
" U
ST
8" SAN
8" SAN
8" S
AN
4" SAN
4"
4"
8" S
AN
8"
S
AN
4" SAN
4"2"
2"
2"
8" S
AN
4"
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4"
4"
4" SAN4"
2"
4" UST
4"
4" SAN
4"
4" SAN
4" SAN
4"
2"
4" SAN
4" S
AN
2"
8" UST
2" SAN
2" S
AN
2"
S
AN
6" UST
6" U
ST
2"
8" S
AN
" U
ST
1 2
6" U
S
6" US 6" US
5 6
C.O.
C.O.
FW/FCO
C.O.
C.O.
C.O.
FW/FCO
4" SAN2" SAN
F.D.
F.D.
A.D.
A.D.
A.D.
A.D.
4" U
ST
4"
U
ST
4" U
ST
2" SAN
UST
UST
U
ST
U
ST
UST
C.O.
4" SAN
2" S
AN
6" U
S
C.O.
C.O.
C.O.
4" D
S
6" U
S
2"2"2"
2" SAN
4"
FW/FCO
FW/FCO
8" DS
4" US
4" S
AN
C.O.
4"
PE-1
3" V
EN
T
OUTPATIENT PHARMACY
1/
2" S
A N
4" D
S
C.O.
4" S
AN
3" VENT
2"
FINISHED FLOOR = 649.5
4" DT
4" DT
4" DRAIN TILE (TYPICAL)
4" DT
4" DT
BAC318 BAC317
BAC316
BS1 BAC309
BAC308
BAC307
BA109A
BA111-1
BS5-1
BA109
BA109C
BS3
BAC306
BAC303
BAC302
BAC301A
BAC301BAC312BAC313
BAC311
BAC330
BAC285
BAC281
BAC282
BAC280
BAC283 BAC253
BAC260B
BAC252 BAC251
BAC250
BAC256
BAC257
BAC258
BAC259
BAC255BAC254
BAC286BAC329
C.O. C.O.
2" S
AN
2 1/2" SAN
UST
4"
4" D
S 4"
D S
C.O.
A.D. 4" UST
6" INVERT = 647.5
6" INVERT = 646.9
6" INVERT = 646.5
F.D.
CODED NOTES
1. EXISTING 4" SAN AND 3" VENT STACKS UP.
2. EXISTING 6" STORM STACK UP.
3. TIE NEW 6" US INTO EXISTING 8" US.
4. INSTALL 4" SAN AND 3" VENT STACKS UP IN WALL ON FLOOR ABOVE.
5. INSTALL 1-1/2" SAN UP TO SINK ON FLOOR ABOVE. EXTEND 1-1/2" VENT UP IN WALL TO CEILING
SPACE.
6. INSTALL 4" SAN UP TO WATER CLOSET ON FLOOR ABOVE. EXTEND 2" VENT UP IN WALL/CHASE
TO CEILING SPACE.
7. INSTALL 1-1/2" SAN UP TO LAV ON FLOOR ABOVE. EXTEND 1-1/2" VENT UP IN WALL TO CEILING
SPACE.
8. INSTALL 4" STORM STACK UP TO ROOF DRAIN.
9. ROUTE NEW FOOTER DRAINAGE PIPING AROUND NEW ADDITION AND RECONNECT INTO
EXISTING SYSTEM. EXISTING BUILDING DRAWINGS INDICATE THE HIGH POINT OF SLOPED
FOOTER DRAINAGE PIPING TO BE NEAR COLUMN (L,54). THE INTENT IS FOR THE HIGH POINT OF THE NEW FOOTER DRAINAGE PIPING TO BE INSTALLED NEAR COLUMN (M,57) AND TO BE SLOPED TOWARDS COLUMN (O,54) AND COLUMN (K,54) @ A MINIMUM OF 0.5%. SURVEY EXISTING INVERTS TO MAINTAIN POSITIVE SLOPE. FIELD VERIFY PRIOR TO CONSTRUCTION. FIELD VERIFY SIZE OF
PIPING.
10. TIE NEW 4" SAN INTO EXISTING 4" SAN STACK.
11. INSTALL 2" SAN IN BASEMENT CEILING SPACE AND EXTEND UP IN WALL ON FLOOR ABOVE.
EXTEND 1-1/2" SAN TO SINK ON FLOOR ABOVE. EXTEND 1-1/2" VENT UP IN WALL TO CEILING
SPACE.
12. INSTALL SUMP PUMP AND BASIN. INSTALL 2" PUMP DISCHARGE UP ALONG WALL TO CEILING
SPACE. REFER TO DETAIL FOR ADDITIONAL INFORMATION. COORDINATE ELECTRICAL
REQUIREMENTS WITH E.C.
13. INSTALL 4" SAN AND 3" VENT STACKS UP ALONG COLUMN TO BASEMENT CEILING SPACE.
14. HEAVY DASHED BOUNDARY INDICATES OUTPATIENT PHARMACY. REFER TO ARCHITECTURAL
PLAN AS-0.1 FOR SPECIAL TIMEFRAME AND INFECTION CONTROL REQUIREMENTS AND STAFFING RESTRICTIONS THAT MUST BE STRICTLY ADHERED TO. COORDINATE CONSTRUCTION ACTIVITIES
WITH VA COR AHEAD OF TIME TO ENSURE ALL PROTECTIVE MEASURES ARE IN PLACE.
15. INSTALL 8" STORM PIPE THROUGH WALL AT INVERT = 664.0. EXTEND 8" STORM PIPE TO TIE INTO CLEANOUT AS SHOWN ON CIVIL DRAWING GS-3. SEE CIVIL DRAWINGS FOR CONTINUATION.
16. PROVIDE OPENING IN SUMP CROCK FOR EXTENSION OF UNDERSLAB DRAINAGE SYSTEM.
REFER TO STRUCTURAL DRAWING S-1.0 FOR UNDERSLAB DRAINAGE SYSTEM INFORMATION.
17. INSTALL 4" PERFORATED DRAIN TILE UNDER SLAB. REFER TO STRUCTURAL DRAWING S-1.0
AND S-5.0 FOR UNDERSLAB DRAINAGE SYSTEM INFORMATION.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:3
PM
P-0.2-1
BASEMENT LEVEL PHASE I PLUMBING WASTE
IMPROVEMENT PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
BASEMENT LEVEL PHASE I PLUMBING WASTE IMPROVEMENT PLAN
ROOM LEGEND
BA109 Mechanical Room
BA109A Areawell Access BA109C Office BA110-1 Outside Air Enclosure-1 BA111-1 Mechanical Room-1 BAC250 Waiting
BAC250B Passage BAC251 Triage BAC252 Exam BAC253 Exam BAC254 Exam BAC255 Exam BAC256 Records BAC257 Office BAC258 Soiled Holding BAC259 Clean Supply
BAC260B Passage BAC280 Anti-Coagulation Clinic Open Office BAC281 Office BAC282 Copy File/Work BAC283 Break Room BAC285 Storage, File Room BAC286 Conference Room BAC301 Storage
BAC301A HD Storage Room
BAC302 HAC
BAC303 Staff Lockers/Break BAC306 Office BAC307 Work Room BAC308 Comm BAC309 Electrical Closet BAC311 Outpatient Pharmacy BAC312 Tech Sup. Mail Order BAC313 Consult Room BAC316 Supervisor BAC317 Tech Supply BAC318 Controlled Sub,/ Sec Disp BAC325 Elevator Lobby BAC326 Waiting BAC327 Corridor BAC328 Corridor BAC329 Womens BAC330 Mens
BS1 Stair 1 BS3 Stair 3
BS5-1 Stair 5-1
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
FE
C
FEC
REF
49 50 50.3 51 52 53
J
K
K4
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
2 1/2"
1 1/2" DHW
3/4"
2"
1/ 4"
3/ 4"
2"
1/ 4"
3/ 4"
1/2" 3/4"
1 1/2"
1/2" 3/4"
1 1/2" 1/2"
1 1/4"
1/2"
1 1/4" 3/4"
1/2"
1/ 2"
1"
1/ 2"
1 1/2" 3/4"
1/2"
1 1/2" 3/4"
1/2"
1/2" 3/4"
1 1/2"3/4" 3/4"
1/2"
1" DCW
1" DHW
1/2" RDHW
3/4" 3/4"
1/2" 1/2"
1" DCW
1" DHW
1/2" RDHW
1/ 2"
R D
H W
1" D
H W
1" D
C W
2 2 2 2
2 2
3/ 4"
D C
W
P-801
1/ 2"
D C
W 1/
2" D
H W
1/ 2"
R D
H W
1/2" RDHW
1/2" DHW
1/2" DCW
1/ 2"
R D
H W
1/ 2"
D H
W 1/
2" D
C W
BALANCE TO .5 GPM
(TYP.)
1A104-1
1S1-1 1A113-1 1A114-1
1A115-1 1A116-1 1A117-1 1A118-1 1A119-1
1A120-2
1A121-1
1A130-1
1A129-1
1A122-1 1A123-1
1A128-1
1A127-1
1A124-1 1A125-1
1A126-1
1A100A-1
1A112
1A111C
1A111A
1A111
1A108-1
1A109
1A110
1A111B
1A105-1
1A138
1A139-1
1A137B
1A137A
1A137D-1
1A137C-1 1A140-1
1A136-1
1A135-1
1A141-1 1A142-1
1A134-1
1A100C-1
1A132-1
1A144-1
1A143-1
1A133-1
1A100D-1
1A148-1
1A166 1A164
1A149-11A150-1
1A162-11A160
1A151-11A152
1A158
1A217-1
1A155-1
1A154 1A153A-1
1A153B-1
1A156
1A171-1 1A170 1A169-1
1A157A-1
1A157 1A159
1A161-1 1A163-1 1A165
1A100E-1
1A105-1
1A102-1
1A216-1
1A214-1
1A100G-1
1AC290-1
1AC288-1
1AC289A-1
1AC289B-1
1AC220-1
1AC221-1 1AC222-1
1AC223-1
1AC220A-1
1A100F-1
1S3-1
1A181-1
1AC226-1
1AC291-1
1A213-1
1A129
1A134-21A133-2
1A132-1 1A131-1
1A136-1 1A137-1 1A138-1 1A139-1
1S5A-1 1S5-1
1A140-1
1A141-1
1A142-1
1A143-1
1A143A-1 1A144-1
1A145-1
1A146-1
CODED NOTES
1. EXISTING 3" DCW, 2" DHW AND 1" RDHW RISERS DOWN TO BASEMENT, AND 2-1/2" DCW, 2" DHW
AND 1" RDHW UP TO SECOND FLOOR.
2. INSTALL 1/2" DCW, 1/2" DHW AND 1/2" RDHW PIPING DOWN IN WALL TO SINK.
3. INSTALL 2-1/2" DCW, 2" DHW AND 1" RDHW PIPE RISERS DOWN IN WALL TO BASEMENT.
4. INSTALL 1/2" DCW, 1/2" DHW AND 1/2" RDHW PIPING DOWN IN WALL TO LAV.
5. INSTALL 1-1/4" DCW WITH SHOCK STOP DOWN IN WALL/CHASE TO WATER CLOSET.
6. OFFSET 2-1/2" DCW, 2" DHW AND 1" RDHW PIPE RISERS IN FIRST FLOOR CEILING SPACE AND
EXTEND UP IN WALL ON FLOOR ABOVE.
7. INSTALL 3/4" DCW LINE DOWN IN INTERIOR WALL AND EXTEND TO FROST PROOF RECESSED
WALL HYDRANT. COORDINATE FINAL ELEVATION WITH ARCHITECTURAL PLANS.
8. DASHED LINE INDICATES NEW 1 HR FIRE/SMOKE BARRIER.
9. INSTALL 1/2" DCW LINE WITH BALL VALVE AND DOUBLE CHECK VALVE (ASSE 1022) IN CEILING
SPACE. EXTEND 1/2" DCW LINE DOWN IN WALL TO COLD WATER HOOK-UP BOX. PROVIDE
ROUGH-IN AND FINAL CONNECTIONS TO REFRIGERATOR WITH ICE MACHINE.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:2
PM
P-1.1-1
FIRST FLOOR LEVEL PHASE I PLUMBING
PIPING IMPROVEMENT PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
FIRST FLOOR LEVEL PHASE I PLUMBING PIPING IMPROVEMENT PLAN
ROOM LEGEND
1A100A-1 Corridor-1 1A100C-1 Corridor-1 1A100D-1 Corridor-1 1A100E-1 Corridor-1 1A100F-1 Corridor-1 1A100G-1 Corridor-1 1A102-1 Reception-1 1A104-1 Lobby-1 1A105-1 Waiting Room-1 1A105-1 Waiting-1 1A108-1 Toilet-1 1A109 LPN Work Area 1A110 LPN Work Area 1A111 LPN Work Area
1A111A Office 1A111B Office 1A111C Lockers 1A112 Soiled Utility
1A113-1 Electrical-1 1A114-1 Telecomm-1 1A115-1 Exam/Treatment Room-1 1A116-1 Exam/Treatment Room-1 1A117-1 Exam/Treatment Room-1 1A118-1 Exam/Treatment Room-1 1A119-1 Exam/Treatment Room-1 1A120-2 Precepting Room-2 1A121-1 Clean Utility-1 1A122-1 Exam/Treatment Room-1 1A123-1 Exam/Treatment Room-1 1A124-1 Exam/Treatment Room-1 1A125-1 Exam/Treatment Room-1 1A126-1 Exam/Treatment Room-1 1A127-1 Exam/Treatment Room-1 1A128-1 Exam/Treatment Room-1 1A129 PACT Team Hub - North
1A129-1 Exam/Treatment Room-1 1A130-1 Exam/Treatment Room-1 1A131-1 Exam/Treatment Room-1 1A132-1 Diabetes Education Office-1 1A132-1 Exam/Treatment Room-1 1A133-1 Exam/Treatment Room-1 1A133-2 Exam/Treatment Room-2 1A134-1 Exam/Treatment Room-1 1A134-2 Exam/Treatment Room-2 1A135-1 Exam/Treatment Room-1 1A136-1 Social Work Office-1 1A136-1 Exam/Treatment Room-1 1A137-1 Exam/Treatment Room-1 1A137A GS6 Office 1A137B GS9 Office
1A137C-1 Check-Out-1 1A137D-1 Check-Out-1
1A138 Mas Reception 1 1A138-1 Exam/Treatment Room-1 1A139-1 Mas Reception 2-1 1A139-1 Exam/Treatment Room-1 1A140-1 Social Work Office-1 1A140-1 PACT Team Hub - South-1 1A141-1 Exam/Treatment Room-1 1A141-1 Nurse Managers Office-1 1A142-1 Exam/Treatment Room-1 1A142-1 Director's Office-1 1A143-1 Exam/Treatment Room-1 1A143-1 Precepting Room-1
1A143A-1 Elec. Closet-1 1A144-1 Break Room-1 1A144-1 Staff Toilet-1 1A145-1 Exam/Treatment Room-1 1A146-1 Exam/Treatment Room-1 1A148-1 Exam/Treatment Room-1 1A149-1 Exam/Treatment Room-1 1A150-1 Exam/Treatment Room-1 1A151-1 Exam/Treatment Room-1 1A152 Exam/Treatment Room
1A153A-1 Consult.-1 1A153B-1 Consult.-1
1A154 Men's 1A155-1 RR Alcove-1 1A156 Women's 1A157 Lead Techs Work Room
1A157A-1 Staff Toilet-1 1A158 Exam/Treatment Room 1A159 Exam/Treatment Room 1A160 Exam/Treatment Room
1A161-1 Exam/Treatment Room-1 1A162-1 Exam/Treatment Room-1 1A163-1 Exam/Treatment Room-1 1A164 Exam/Treatment Room 1A165 Exam/Treatment Room 1A166 Exam/Treatment Room
1A169-1 On-Call Room-1 1A170 Program Support Asst.
1A171-1 Nurse Manager-1 1A181-1 Comm Clos-1 1A213-1 Restroom Alcove-1 1A214-1 Womens-1 1A216-1 Vending-1 1A217-1 Elevator Lobby-1
1AC220-1 Waiting Room-1 1AC220A-1 Passage-1 1AC221-1 Reception-1 1AC222-1 Toilet-1 1AC223-1 Radiology 1-1 1AC226-1 View Sort-1 1AC288-1 Fast Track Exam 2-1
1AC289A-1 Conference Room-1 1AC289B-1 Staff Lounge-1 1AC290-1 Fast Track Exam 3-1 1AC291-1 Corridor-1
1S1-1 Stair 1-1 1S3-1 Stair 3-1 1S5-1 Stair 5-1
1S5A-1 Stair 5 Vest.-1
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
FE
C
FEC
REF
49 50 50.3 51 52 53
J
K
K4
L
M
M.8
N
N.1
N.2
N.3
O
P
575654.554.153A 54
2 3
2" S
AN
1/ 2"
S A
N
C.O.
C.O.
C.O.
2" SAN
P-529 P-529 P-529
P-529
P-529
P-529
4 4
C.O.
C.O.
C.O. C.O.
4"
2" SAN
C.O.
2" SAN4" SAN4" SAN
C.O.
1A104-1
1S1-1 1A113-1 1A114-1
1A115-1 1A116-1 1A117-1 1A118-1 1A119-1
1A120-2
1A121-1
1A130-1
1A129-1
1A122-1 1A123-1
1A128-1
1A127-1
1A124-1 1A125-1
1A126-1
1A100A-1
1A112
1A111C
1A111A
1A111
1A108-1
1A109
1A110
1A111B
1A105-1
1A138
1A139-1 1A137B
1A137A
1A137D-1
1A137C-1 1A140-1
1A136-1
1A135-1
1A141-1 1A142-1
1A134-1
1A100C-1
1A132-1
1A144-1
1A143-1
1A133-1
1A100D-1
1A148-1
1A1661A164
1A149-11A150-1
1A162-1 1A160
1A151-11A152
1A158
1A217-1
1A155-1
1A154 1A153A-1
1A153B-1
1A156
1A171-1 1A170 1A169-1
1A157A-1
1A157 1A159
1A161-1 1A163-1 1A165
1A100E-1
1A105-1
1A102-1
1A216-1
1A214-1
1A100G-1
1AC290-1
1AC288-1
1AC289A-1
1AC289B-1
1AC220-1
1AC221-1 1AC222-1
1AC223-1
1AC220A-1
1A100F-1
1S3-1
1A181-1
1AC226-1
1AC291-1
1A213-1
1A129
1A134-2 1A133-2
1A132-1
1A131-1
1A136-1
1A137-1
1A138-1 1A139-1
1S5A-1 1S5-1
1A140-1
1A141-1
1A142-1
1A143-1
1A143A-1 1A144-1
1A145-1
1A146-1
P-103
P-529
P-529
P-529 P-529
P-528
4" SAN
2" S
AN
C.O.
C.O.
P-413
P-529
CODED NOTES
1. EXISTING 4" SAN AND 3" VENT STACKS.
2. INSTALL 4" SAN AND 3" VENT STACKS.
3. INSTALL 1-1/2" SAN UP TO SINK ON FLOOR ABOVE. EXTEND 1-1/2" VENT UP IN WALL TO CEILING
SPACE.
4. INSTALL 1-1/2" SAN IN WALL TO SINK. EXTEND 1-1/2" VENT UP IN WALL TO CEILING SPACE.
5. OFFSET 4" SAN AND 3" VENT STACKS IN FIRST FLOOR CEILING SPACE AND EXTEND UP IN WALL.
6. OFFSET 4" STORM STACK IN FIRST FLOOR CEILING SPACE AND EXTEND DOWN TO BELOW
BASEMENT FLOOR SLAB.
7. INSTALL 4" SAN UP INTO CHASE ON FLOOR ABOVE. EXTEND 4" SAN TO WATER CLOSET
FLANGE AND 1-1/2" SAN TO LAV. EXTEND 2" VENT UP FROM WATER CLOSET AND 1-1/2" VENT UP
FROM LAV. TIE TOGETHER IN CHASE AND EXTEND 2" VENT UP TO CEILING SPACE.
8. DASHED LINE INDICATES NEW 1 HR FIRE/SMOKE BARRIER.
9. EXTEND 4" STORM STACK UP TO SECOND FLOOR CEILING SPACE AND DOWN TO BELOW
BASEMENT FLOOR SLAB.
PLAN NOTES
A. THIS DRAWING WAS DESIGNED TO PLOT AS 30" X 42" PLOT. IF PLOT DOES NOT MATCH THE
DESIGNED SIZE, THE GRAPHICAL SCALE SHALL BE USED.
B. SEE SHEET P-001 FOR PLUMBING SYMBOL LEGEND, PLUMBING GENERAL NOTES, AND
PLUMBING DETAILS.
DATESIGNATURE
SCHOONOVER
C. J.
ST
AT
E OF O
H IO
P R O F E
SS IO N
AL EN
G
IN
E E R
REG IS T E R
ED
E-62197
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C :\U se rs
\a m ca le es e\
D oc um en ts \1
_M
EP
_C
EN
TR
AL
F
IL
E_ am ca le es e.
rv t
7/
/2
4:
:5
PM
P-1.2-1
FIRST FLOOR LEVEL PHASE I PLUMBING
WASTE IMPROVEMENT PLAN
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
NICK CARROZZA
8.1.21 CJS DMR
BID ISSUE SUBMISSION
8.1.21
N 1/8" = 1'-0"
FIRST FLOOR LEVEL PHASE I PLUMBING WASTE IMPROVEMENT PLAN
ROOM LEGEND
1A100A-1 Corridor-1 1A100C-1 Corridor-1 1A100D-1 Corridor-1 1A100E-1 Corridor-1 1A100F-1 Corridor-1 1A100G-1 Corridor-1 1A102-1 Reception-1 1A104-1 Lobby-1 1A105-1 Waiting Room-1 1A105-1 Waiting-1 1A108-1 Toilet-1 1A109 LPN Work Area 1A110 LPN Work Area 1A111 LPN Work Area
1A111A Office 1A111B Office 1A111C Lockers 1A112 Soiled Utility
1A113-1 Electrical-1 1A114-1 Telecomm-1 1A115-1 Exam/Treatment Room-1 1A116-1 Exam/Treatment Room-1 1A117-1 Exam/Treatment Room-1 1A118-1 Exam/Treatment Room-1 1A119-1 Exam/Treatment Room-1 1A120-2 Precepting Room-2 1A121-1 Clean Utility-1 1A122-1 Exam/Treatment Room-1 1A123-1 Exam/Treatment Room-1 1A124-1 Exam/Treatment Room-1 1A125-1 Exam/Treatment Room-1 1A126-1 Exam/Treatment Room-1 1A127-1 Exam/Treatment Room-1 1A128-1 Exam/Treatment Room-1 1A129 PACT Team Hub - North
1A129-1 Exam/Treatment Room-1 1A130-1 Exam/Treatment Room-1 1A131-1 Exam/Treatment Room-1 1A132-1 Diabetes Education Office-1 1A132-1 Exam/Treatment Room-1 1A133-1 Exam/Treatment Room-1 1A133-2 Exam/Treatment Room-2 1A134-1 Exam/Treatment Room-1 1A134-2 Exam/Treatment Room-2 1A135-1 Exam/Treatment Room-1 1A136-1 Social Work Office-1 1A136-1 Exam/Treatment Room-1 1A137-1 Exam/Treatment Room-1 1A137A GS6 Office 1A137B GS9 Office
1A137C-1 Check-Out-1 1A137D-1 Check-Out-1
1A138 Mas Reception 1 1A138-1 Exam/Treatment Room-1 1A139-1 Mas Reception 2-1 1A139-1 Exam/Treatment Room-1 1A140-1 Social Work Office-1 1A140-1 PACT Team Hub - South-1 1A141-1 Exam/Treatment Room-1 1A141-1 Nurse Managers Office-1 1A142-1 Exam/Treatment Room-1 1A142-1 Director's Office-1 1A143-1 Exam/Treatment Room-1 1A143-1 Precepting Room-1
1A143A-1 Elec. Closet-1 1A144-1 Break Room-1 1A144-1 Staff Toilet-1 1A145-1 Exam/Treatment Room-1 1A146-1 Exam/Treatment Room-1 1A148-1 Exam/Treatment Room-1 1A149-1 Exam/Treatment Room-1 1A150-1 Exam/Treatment Room-1 1A151-1 Exam/Treatment Room-1 1A152 Exam/Treatment Room
1A153A-1 Consult.-1 1A153B-1 Consult.-1
1A154 Men's 1A155-1 RR Alcove-1 1A156 Women's 1A157 Lead Techs Work Room
1A157A-1 Staff Toilet-1 1A158 Exam/Treatment Room 1A159 Exam/Treatment Room 1A160 Exam/Treatment Room
1A161-1 Exam/Treatment Room-1 1A162-1 Exam/Treatment Room-1 1A163-1 Exam/Treatment Room-1 1A164 Exam/Treatment Room 1A165 Exam/Treatment Room 1A166 Exam/Treatment Room
1A169-1 On-Call Room-1 1A170 Program Support Asst.
1A171-1 Nurse Manager-1 1A181-1 Comm Clos-1 1A213-1 Restroom Alcove-1 1A214-1 Womens-1 1A216-1 Vending-1 1A217-1 Elevator Lobby-1
1AC220-1 Waiting Room-1 1AC220A-1 Passage-1 1AC221-1 Reception-1 1AC222-1 Toilet-1 1AC223-1 Radiology 1-1 1AC226-1 View Sort-1 1AC288-1 Fast Track Exam 2-1
1AC289A-1 Conference Room-1 1AC289B-1 Staff Lounge-1 1AC290-1 Fast Track Exam 3-1 1AC291-1 Corridor-1
1S1-1 Stair 1-1 1S3-1 Stair 3-1 1S5-1 Stair 5-1
1S5A-1 Stair 5 Vest.-1
Revisions: Date:
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19 90% CD's SUBMISSION 8.9.19
C
FE
C
FEC
C G
-1
CG-1
CG-1 CG-1
CG-1
CG-1CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1CG-1
CG-1 CG-1
CG-1
CG-1
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .