This solicitation is for a construction project to expand primary care facilities at the Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio. The contractor shall provide all labor, equipment, supplies, and supervision necessary to add approximately 12,000 square feet of space across three floors by expanding the existing ambulatory care addition. The project budget is estimated between $10-15 million. Requests for information are due by August 12, 2021 and shall be emailed to the contracting officer. This is a 100% set-aside for a Service-Disabled Veteran Owned Small Business. Bidders must be verified in VETBIZ and registered in SAM by the time of offer and award to be eligible. The NAICS code for this project is 236220 with a size standard of $39.5 million.
View the file
Other files for this federal contract opportunity
Show all 34
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: NICK CARROZZA
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
E T
G
DE
I
RET
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
AT
E
I
T C
J.
O
O
FO
H
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C U s e rs
\d a v e
\D o c u m e n ts \E x p a n d P ri m a ry
C a re
R d a k a p la n
.r v t
/3
/2
:2
:5
P
M
BID ISSUE SUBMISSION
GI-1
TITLE SHEET & DRAWING INDEX EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
8.1.21 CJK DAK
DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER - WADE PARK
EXPAND PRIMARY CARE FOR PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OH 44106
PROJECT NO. 541-376
Cleveland Veterans Affairs Medical Center
SCOPE OF WORK
GROUND LEVEL
NORTH
CODE INFORMATION:
I. PROJECT LOCATION: CLEVELAND VETERANS AFFAIRS MEDICAL CENTER
10701 EAST BLVD.
CLEVELAND, OHIO
II. DESCRIPTION & USER GROUP CLASSIFICATION OF BUILDING
A. NATURE OF PROJECT: TWO-STORY ADDITION TO AND INTERIOR RENOVATIONS OF EXISTING 1ST
FLOOR PRIMARY CARE DEPARTMENT, 2ND FLOOR SPECIALTY CARE
DEPARTMENT, AND BASEMENT LEVEL MECHANICAL ROOM
B. DESIGN CODES: 2018 NFPA LIFE SAFETY CODE 101, IBC 2018, ABAAS & VA BARRIER-FREE GUIDELINES
C. USE GROUP: 1ST & 2ND FLOORS: B - AMBULATORY CARE FACILITY (EXISTING)
BASEMENT LEVEL: S - STORAGE
D. CONSTRUCTION TYPE: TYPE I-332, IA - NON-COMBUSTIBLE, PROTECTED
FIRE RATED CONSTRUCTION (LSC A.8.2.1.1)
EXTERIOR BEARING WALLS 3 HRS
INTERIOR BEARING WALLS 3 HRS
STRUCTURAL COLUMNS 3 HRS (SUPPORTING > 1 FLOOR)
2 HRS (SUPPORTING 1 FLOOR ONLY)
2 HRS (SUPPORTING ROOF ONLY)
BEAMS, GIRDERS, TRUSSES 3 HRS (SUPPORTING > 1 FLOOR, COLS., OR BEARING WALLS)
FLOOR-CEILING ASSEMBLIES 2 HRS
ROOF-CEILING ASSEMBLIES 1-1/2 HRS
INTERIOR NON-BEARING WALLS 0 HRS
EXTERIOR NON-BEARING WALLS 0 HRS
WALL ASSEMBLIES
FIRE PARTITIONS 1 HR
SMOKE BARRIERS 1 HR
STAIR ENCLOSURES 2 HRS
SHAFT ENCLOSURES 2 HRS
E. PROJECT AREA: BASEMENT LEVEL: 5,422 GSF ADDITON
FIRST FLOOR: 10,170 SF INTERIOR RENOVATION + 5,102 GSF ADDITION
SECOND FLOOR: 1,067 SF INTERIOR RENOVATION + 5,216 GSF ADDITION
F. PROJECT AREA OCCUPANT LOAD: BASEMENT LEVEL: 19
FIRST FLOOR: 153
SECOND FLOOR: 63
G. FIRE PROTECTION: FULLY SPRINKLED - EXISTING AND ADDITION. EXISTING FIRE PROTECTION
SYSTEM TO BE MODIFIED AS REQUIRED FOR NEW IMPROVEMENTS. DESIGN
SHALL BE COMPLETED SEPARATELY BY A LICENSED FIRE PROTECTIONS
SYSTEM DESIGNER.
DRAWING INDEX:
BID ISSUE SUBMISSION
8.1.21
GI-1 TITLE SHEET & DRAWING INDEX
ARCHITECTURAL
LS-0.1 BASEMENT LEVEL LIFE SAFETY PLAN - PHASE I
LS-1.1 FIRST FLOOR LIFE SAFETY PLAN - PHASE I
LS-1.2 FIRST FLOOR LIFE SAFETY PLAN - PHASE II
LS-1.3 FIRST FLOOR LIFE SAFETY PLAN - PHASE III
LS-1.4 FIRST FLOOR LIFE SAFETY PLAN - PHASE IV
LS-1.5 FIRST FLOOR LIFE SAFETY PLAN - PHASE V
LS-2.1 SECOND FLOOR LIFE SAFETY PLAN - PHASE I
AS-X-0.1 BASEMENT LEVEL EXISTING CONDITIONS PLAN
AS-D-0.1 BASEMENT LEVEL - DEMOLITION PLAN - PHASE I
AS-0.1 BASEMENT LEVEL PROPOSED IMPROVEMENT/ADDITION PLAN - PHASE I
AS-C-0.1 BASEMENT LEVEL - REFLECTED CEILING PLAN - PHASE I
AS-X-1.1 1ST FLOOR PRIMARY CARE DEPT. - EXISTING CONDITIONS PLAN
AS-D-1.1 1ST FLOOR PRIMARY CARE DEPT. - DEMOLITION PLAN - PHASE I
AS-DC-1.1 1ST FLOOR PRIMARY CARE DEPT. - CEILING DEMOLITION PLAN - PHASE I
AS-1.1 1ST FLOOR PRIMARY CARE DEPT. - PROPOSED IMPROVEMENT/ADDITION PLAN -
PHASE I ADDITION
AS-1.1A 1ST FLOOR PRIMARY CARE DEPT. - PROPOSED IMPROVEMENT PLAN -
PHASE I INTERIORS
AS-C-1.1 1ST FLOOR PRIMARY CARE DEPT. - REFLECTED CEILING PLAN - PHASE I
AS-D-1.2 1ST FLOOR PRIMARY CARE DEPT. - DEMOLITION PLAN - PHASE II
AS-DC-1.2 1ST FLOOR PRIMARY CARE DEPT. - CEILING DEMOLITION PLAN - PHASE II
AS-1.2 1ST FLOOR PRIMARY CARE DEPT. - PROPOSED IMPROVEMENT PLAN - PHASE II
AS-C-1.2 1ST FLOOR PRIMARY CARE DEPT. - REFLECTED CEILING PLAN - PHASE II
AS-D-1.3 1ST FLOOR PRIMARY CARE DEPT. - DEMOLITION PLAN - PHASE III
AS-DC-1.3 1ST FLOOR PRIMARY CARE DEPT. - CEILING DEMOLITION PLAN - PHASE III
AS-1.3 1ST FLOOR PRIMARY CARE DEPT. - PROPOSED IMPROVEMENT PLAN - PHASE III
AS-C-1.3 1ST FLOOR PRIMARY CARE DEPT. - REFLECTED CEILING PLAN - PHASE III
AS-D-1.4 1ST FLOOR PRIMARY CARE DEPT. - DEMOLITION PLAN - PHASE IV
AS-DC-1.4 1ST FLOOR PRIMARY CARE DEPT. - CEILING DEMOLITION PLAN - PHASE IV
AS-1.4 1ST FLOOR PRIMARY CARE DEPT. - PROPOSED IMPROVEMENT PLAN - PHASE IV
AS-C-1.4 1ST FLOOR PRIMARY CARE DEPT. - REFLECTED CEILING PLAN - PHASE IV
AS-D-1.5 1ST FLOOR PRIMARY CARE DEPT. - DEMOLITION PLAN - PHASE V
AS-DC-1.5 1ST FLOOR PRIMARY CARE DEPT. - CEILING DEMOLITION PLAN - PHASE V
AS-1.5 1ST FLOOR PRIMARY CARE DEPT. - PROPOSED IMPROVEMENT PLAN - PHASE V
AS-C-1.5 1ST FLOOR PRIMARY CARE DEPT. - REFLECTED CEILING PLAN - PHASE V
AS-X-2.1 2ND FLOOR SPECIALTY CARE DEPT. - EXISTING CONDITIONS PLAN
AS-D-2.1 2ND FLOOR SPECIALTY CARE DEPT. - DEMOLITION PLAN - PHASE I
AS-DC-2.1 2ND FLOOR SPECIALTY CARE DEPT. - CEILING DEMOLITION PLAN - PHASE I
AS-2.1 2ND FLOOR SPECIALTY CARE DEPT. - PROPOSED IMPROVEMENT/ADDITION
PLAN - PHASE I ADDITION
AS-2.1A 2ND FLOOR SPECIALTY CARE DEPT. - PROPOSED IMPROVEMENT/ADDITION
PLAN - PHASE I INTERIORS
AS-2.1B 2ND FLOOR SPECIALTY CARE DEPT. - DEDUCT ALTERNATE 1-3 PLANS
AS-C-2.1 2ND FLOOR SPECIALTY CARE DEPT. - REFLECTED CEILING PLAN - PHASE I
AS-C-2.1B 2ND FLOOR SPECIALTY CARE DEPT. - DEDUCT ALTERNATE 1-3 CEILING PLANS
AS-3.1 THIRD FLOOR/NEW ADDITION ROOF PLAN - PHASE I
AS-200 NEW ADDITION EXTERIOR ELEVATIONS
AS-201 WALL SECTIONS
AS-202 WALL SECTIONS
AS-203 WALL SECTIONS
AS-204 ENLARGED STAIR SECTION, PLANS, AND DETAILS
AS-300 ENLARGED PLANS AND INTERIOR ELEVATIONS
AS-301 ENLARGED PLANS AND INTERIOR ELEVATIONS
AS-302 ENLARGED PLANS AND INTERIOR ELEVATIONS
AS-303 INTERIOR ELEVATIONS
AS-304 INTERIOR ELEVATIONS
AS-305 INTERIOR ELEVATIONS
AS-306 MILLWORK DETAILS
AS-400 ENLARGED PLAN & SECTION DETAILS
AS-401 ENLARGED SECTION DETAILS
AS-600 WINDOW TYPES
AS-601 WALL TYPES
AS-700 DOOR SCHEDULE AND DETAILS
AS-701 1ST FLOOR - MASTER FINISH PLAN
AS-702 BASEMENT LEVEL AND 2ND FLOOR - MASTER FINISH PLANS
AS-703 FINISH SCHEDULE AND DETAILS
MECHANICAL/HVAC
H-001 HVAC GENERAL NOTES AND SYMBOL LEGEND
H-002 HVAC DETAILS
H-003 HVAC DETAILS
H-004 HVAC TEMPERATURE CONTROLS
H-005 HVAC TEMPERATURE CONTROLS
H-006 HVAC SCHEDULES
H-007 HVAC SECTIONS AT BASEMENT LEVEL
H-D-0-1 BASEMENT LEVEL PHASE I HVAC DEMOLITION PLAN
H-0.1-1 BASEMENT LEVEL PHASE I HVAC DUCTWORK IMPROVEMENT PLAN
H-0.2-1 BASEMENT LEVEL PHASE I HVAC PIPING IMPROVEMENT PLAN
H-D-1-1 FIRST FLOOR LEVEL PHASE I HVAC DEMOLITION PLAN
H-1.1-1 FIRST FLOOR LEVEL PHASE I HVAC DUCTWORK IMPROVEMENT PLAN
H-1.2-1 FIRST FLOOR PHASE PHASE I HVAC PIPING IMPROVEMENT PLAN
H-D-1-2 FIRST FLOOR LEVEL PHASE II HVAC DEMOLITION PLAN
H-1.1-2 FIRST FLOOR LEVEL PHASE II HVAC DUCTWORK IMPROVEMENT PLAN
H-1.2-2 FIRST FLOOR LEVEL PHASE II HVAC PIPING IMPROVEMENT PLAN
H-D-1-3 FIRST FLOOR LEVEL PHASE III HVAC DEMOLITION PLAN
H-1.1-3 FIRST FLOOR LEVEL PHASE III HVAC DUCTWORK IMPROVEMENT PLAN
H-1.2-3 FIRST FLOOR LEVEL PHASE III HVAC PIPING IMPROVEMENT PLAN
H-D-1-4 FIRST FLOOR LEVEL PHASE IV HVAC DEMOLITION PLAN
H-1.1-4 FIRST FLOOR LEVEL PHASE IV HVAC DUCTWORK IMPROVEMENT PLAN
H-1.2-4 FIRST FLOOR LEVEL PHASE IV HVAC PIPING IMPROVEMENT PLAN
H-D-1-5 FIRST FLOOR LEVEL PHASE V HVAC DEMOLITION PLAN
H-1.1-5 FIRST FLOOR LEVEL PHASE V HVAC DUCTWORK IMPROVEMENT PLAN
H-1.2-5 FIRST FLOOR LEVEL PHASE V HVAC PIPING IMPROVEMENT PLAN
H-D-2-1 SECOND FLOOR LEVEL PHASE I HVAC DEMOLITION PLAN
H-2.1-1 SECOND FLOOR LEVEL PHASE I HVAC DUCTWORK IMPROVEMENT PLAN
H-2.2-1 SECOND FLOOR LEVEL PHASE I HVAC PIPING IMPROVEMENT PLAN
STRUCTURAL
S-0.1 GENERAL NOTES
S-0.2 GENERAL NOTES
S-0.3 GENERAL NOTES
S-1.0 FOUNDATION PLAN - PHASE I
S-2.0 FIRST FLOOR FRAMING PLAN - PHASE I
S-3.0 SECOND FLOOR FRAMING PLAN - PHASE I
S-4.0 ROOF/FUTURE THIRD FLOOR SLAB PLAN - PHASE I
S-5.0 FOUNDATION TYPICAL DETAILS
S-5.1 FOUNDATION SECTIONS AND DETAILS
S-5.2 FOUNDATION SECTIONS AND DETAILS
S-6.0 TYPICAL MASONRY DETAILS AND ENLARGED STAIR PLAN AND ELEVATION
S-7.0 CONCRETE TYPICAL DETAILS
S-7.1 FRAMING SECTIONS AND DETAILS
S-8.0 SECTIONS AND DETAILS
S-9.0 SECTIONS AND DETAILS
S-9.1 SECTIONS AND DETAILS
FIRE PROTECTION
FP-001 FIRE PROTECTION GENERAL NOTES, DETAILS, AND SYMBOL LEGEND
FP-0-1 BASEMENT LEVEL PHASE I FIRE PROTECTION IMPROVEMENT PLAN
FP-1-1 FIRST FLOOR LEVEL PHASE I FIRE PROTECTION IMPROVEMENT PLAN
FP-1-2 FIRST FLOOR LEVEL PHASE II FIRE PROTECTION IMPROVEMENT PLAN
FP-1-3 FIRST FLOOR LEVEL PHASE III FIRE PROTECTION IMPROVEMENT PLAN
FP-1-4 FIRST FLOOR LEVEL PHASE IV FIRE PROTECTION IMPROVEMENT PLAN
FP-1-5 FIRST FLOOR LEVEL PHASE V FIRE PROTECTION IMPROVEMENT PLAN
FP-2-1 SECOND FLOOR LEVEL PHASE I FIRE PROTECTION IMPROVEMENT PLAN
CIVIL
GS-0 EXISTING SITE SURVEY
GS-1 SYMBOL LEGEND AND GENERAL NOTES
GS-2 CLEARING AND DEMOLITION PLAN
GS-3 SITE UTILITY AND GRADING PLAN
GS-4 SITE PAVING PLAN
GS-5 EROSION CONTROL NARRATIVE
GS-6 SITE DETAILS
LANDSCAPE/SITE
MSP-01 MASTER SITE IMPROVEMENT PLAN
MSP-02 SITE ELEVATIONS & DETAILS
L-01 LANDSCAPE PLAN
L-02 IRRIGATION PLAN
PLUMBING
P-001 PLUMBING GENERAL NOTES, SCHEDULES, DETAILS, AND SYMBOL LEGEND
P-D-0-1 BASEMENT LEVEL PHASE I PLUMBING DEMOLITION PLAN
P-D-1-1 FIRST FLOOR LEVEL PHASE I PLUMBING DEMOLITION PLAN
P-D-2-1 SECOND FLOOR LEVEL PHASE I PLUMBING DEMOLITION PLAN
P-0.1-1 BASEMENT LEVEL PHASE I PLUMBING PIPING IMPROVEMENT PLAN
P-0.2-1 BASEMENT LEVEL PHASE I PLUMBING WASTE IMPROVEMENT PLAN
P-1.1-1 FIRST FLOOR LEVEL PHASE I PLUMBING PIPING IMPROVEMENT PLAN
P-1.2-1 FIRST FLOOR LEVEL PHASE I PLUMBING WASTE IMPROVEMENT PLAN
P-2.1-1 SECOND FLOOR LEVEL PHASE I PLUMBING PIPING IMPROVEMENT PLAN
P-2.2-1 SECOND FLOOR LEVE PHASE I PLUMBING WASTE IMPROVEMENT PLAN
P-3.2-1 ROOF PLAN PHASE I PLUMBING WASTE IMPROVEMENT PLAN
P-D-0-2 BASEMENT LEVEL PHASE II PLUMBING DEMOLITION PLAN
P-D-1-2 FIRST FLOOR LEVEL PHASE II PLUMBING DEMOLITION PLAN
P-0.2-2 BASEMENT LEVEL PHASE II PLUMBING WASTE IMPROVEMENT PLAN
P-1.1-2 FIRST FLOOR LEVEL PHASE II PLUMBING PIPING IMPROVEMENT PLAN
P-1.2-2 FIRST FLOOR LEVEL PHASE II PLUMBING WASTE IMPROVEMENT PLAN
P-D-0-3 BASEMENT LEVEL PHASE III PLUMBING DEMOLITION PLAN
P-D-1-3 FIRST FLOOR LEVEL PHASE III PLUMBING DEMOLITION PLAN
P-0.2-3 BASEMENT LEVEL PHASE III PLUMBING WASTE IMPROVEMENT PLAN
P-1.1-3 FIRST FLOOR LEVEL PHASE III PLUMBING PIPING IMPROVEMENT PLAN
P-1.2-3 FIRST FLOOR LEVEL PHASE III PLUMBING WASTE IMPROVEMENT PLAN
P-D-0-4 BASEMENT LEVEL PHASE IV PLUMBING DEMOLITION PLAN
P-D-1-4 FIRST FLOOR LEVEL PHASE IV PLUMBING DEMOLITION PLAN
P-0.2-4 BASEMENT LEVEL PHASE IV PLUMBING WASTE IMPROVEMENT PLAN
P-1.1-4 FIRST FLOOR LEVEL PHASE IV PLUMBING PIPING IMPROVEMENT PLAN
P-1.2-4 FIRST FLOOR LEVEL PHASE IV PLUMBING WASTE IMPROVEMENT PLAN
P-D-0-5 BASEMENT LEVEL PHASE V PLUMBING DEMOLITION PLAN
P-D-1-5 FIRST FLOOR LEVEL PHASE V PLUMBING DEMOLITION PLAN
P-0.2-5 BASEMENT LEVEL PHASE V PLUMBING WASTE IMPROVEMENT PLAN
P-1.1-5 FIRST FLOOR LEVEL PHASE V PLUMBING PIPING IMPROVEMENT PLAN
P-1.2-5 FIRST FLOOR LEVEL PHASE V PLUMBING WASTE IMPROVEMENT PLAN
P-002-1 PLUMBING ISOMETRICS - PHASE I
P-002-2 PLUMBING ISOMETRICS - PHASE I & II
P-002-3 PLUMBING ISOMETRICS - PHASE III, IV, & V
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES AND SYMBOL LEGEND
E-002 LIGHTING FIXTURE SCHEDULE - ELECTRICAL
E-003 PANELBOARD SCHEDULES - ELECTRICAL
E-004 MECHANICAL EQUIPMENT SCHEDULE - ELECTRICAL
E-005 PARTIAL ONE-LINE DIAGRAMS - ELECTRICAL
E-006 ELECTRICAL DETAILS - ELECTRICAL
E-007 TELECOM DETAILS - ELECTRICAL
E-008 NURSE CALL DETAILS
ES-1 DEMOLITION SITE UTILITIY PLAN - ELECTRICAL
ES-2 NEW WORK - SITE UTILITY PLAN - ELECTRICAL
E-D-1-1 DEMOLITION - FIRST FLOOR LEVEL PHASE I FLOOR PLAN - ELECTRICAL
E-D-2-1 DEMOLITION - SECOND FLOOR LEVEL PHASE I FLOOR PLAN - ELECTRICAL
E-0.1-1 LIGHTING - BASEMENT LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-0.2-1 POWER - BASEMENT LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-0.3-1 SYSTEMS - BASEMENT LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-1.1-1 LIGHTING - FIRST FLOOR LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-1.2-1 POWER - FIRST FLOOR LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-1.3-1 SYSTEMS - FIRST FLOOR LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-1.4-1 TELECOM - FIRST FLOOR LEVEL PHASE I IMPROVEMENT PLAN - ELECTRICAL
E-2.1-1A LIGHTING - SECOND FLOOR LEVEL PHASE I - BASE BID & DEDUCT ALTERNATE 1 & 2 PLANS
E-2.2-1A POWER - SECOND FLOOR LEVEL PHASE I - BASE BID & DEDUCT ALTERNATE 1 & 2 PLANS
E-2.3-1A SYSTEMS - SECOND FLOOR LEVEL PHASE I - BASE BID & DEDUCT ALTERNATE 1 & 2 PLANS
E-2.4-1A TELECOM - SECOND FLOOR LEVEL PHASE I - BASE BID & DEDUCT ALTERNATE 1 & 2 PLANS
E-2.5-1A LIGHT/PWR/SYS - SECOND FLOOR LEVEL PHASE I - DEDUCT ALT. 3 PLAN
E-D-1-2 DEMOLITION - FIRST FLOOR LEVEL PHASE II FLOOR PLAN - ELECTRICAL
E-1.1-2 LIGHTING - FIRST FLOOR LEVEL PHASE II IMPROVEMENT PLAN - ELECTRICAL
E-1.2-2 POWER - FIRST FLOOR LEVEL PHASE II IMPROVEMENT PLAN - ELECTRICAL
E-1.3-2 SYSTEMS - FIRST FLOOR LEVEL PHASE II IMPROVEMENT PLAN - ELECTRICAL
E-1.4-2 TELECOM - FIRST FLOOR LEVEL PHASE II IMPROVEMENT PLAN - ELECTRICAL
E-D-1-3 DEMOLITION - FIRST FLOOR LEVEL PHASE III FLOOR PLAN - ELECTRICAL
E-1.1-3 LIGHTING - FIRST FLOOR LEVEL PHASE III IMPROVEMENT PLAN - ELECTRICAL
E-1.2-3 POWER - FIRST FLOOR LEVEL PHASE III IMPROVEMENT PLAN - ELECTRICAL
E-1.3-3 SYSTEMS - FIRST FLOOR LEVEL PHASE III IMPROVEMENT PLAN - ELECTRICAL
E-1.4-3 TELECOM - FIRST FLOOR LEVEL PHASE III IMPROVEMENT PLAN - ELECTRICAL
E-D-1-4 DEMOLITION - FIRST FLOOR LEVEL PHASE IV FLOOR PLAN - ELECTRICAL
E-1.1-4 LIGHTING - FIRST FLOOR LEVEL PHASE IV IMPROVEMENT PLAN - ELECTRICAL
E-1.2-4 POWER - FIRST FLOOR LEVEL PHASE IV IMPROVEMENT PLAN - ELECTRICAL
E-1.3-4 SYSTEMS - FIRST FLOOR LEVEL PHASE IV IMPROVEMENT PLAN - ELECTRICAL
E-1.4-4 TELECOM - FIRST FLOOR LEVEL PHASE IV IMPROVEMENT PLAN - ELECTRICAL
E-D-1-5 DEMOLITION - FIRST FLOOR LEVEL PHASE V FLOOR PLAN - ELECTRICAL
E-1.1-5 LIGHTING - FIRST FLOOR LEVEL PHASE V IMPROVEMENT PLAN - ELECTRICAL
E-1.2-5 POWER - FIRST FLOOR LEVEL PHASE V IMPROVEMENT PLAN - ELECTRICAL
E-1.3-5 SYSTEMS - FIRST FLOOR LEVEL PHASE V IMPROVEMENT PLAN - ELECTRICAL
E-1.4-5 TELECOM - FIRST FLOOR LEVEL PHASE V IMPROVEMENT PLAN - ELECTRICAL
Revisions: Date:
SCHEM. DESIGN SUBMISSION 3.15.19
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19
90% CD's SUBMISSION 8.9.19
100% CD's SUBMISSION 2.14.20
BID ISSUE SUBMISSION 8.1.21
E
E
F E
FE
F E
F E
F E
P H
A S
E I S
C O
P E
O F
W O
R K
P H
A S
E I S
C O
P E
O F
W O
R K
E
Outpatient Pharmacy
BAC311
Tech Sup. Mail Order
BAC312
Storage
BAC301
HD Storage Room
BAC301A
Consult Room
BAC313
Consult Room
BAC313
Waiting
BAC326
Staff Lockers/Break
BAC303
HAC
BAC302
Office
BAC306
Mechanical Room
BA109
Stair 3
BS3
Office
BA109C
Corridor
BAC327
Corridor
BAC328
Mechanical Room
BA111
Outside Air Enclosure
BA110
Stair 5
BS5
Stair 1
BS1
Supervisor
BAC316
Tech Supply
BAC317
Controlled Sub,/ Sec Disp
BAC318Record Storage
BAC320
Staff Toilet
BAC319
Consult
BAC321
Waiting
BAC324
Electrical Closet
BAC309
Comm
BAC308
Work Room
BAC307
Areawell Access
BA109A
CONSTRUCTION AREA
EXISTING EGRESS PATHS FROM EXISTING
MECHANICAL ROOM TO REMAIN
UNAFFECTED DURING CONSTRUCTION
19 OCCUPANTS
76'-10" +/- EGRESS TRAVEL
DISTANCE/COMMON PATH OF
TRAVEL
IBC TABLE 1006.3.2(2) STORIES WITH
ONE EXIT OR ACCESS TO ONE EXIT:
-MAXIMUM OCCUPANT LOAD: 29
-MAXIMUM EXIT TRAVEL DISTANCE:
100' (SPRINKLED)
SPECIAL NOTE: AREA WITH DIAGONAL HATCH INDICATES EXISTING OUTPATIENT PHARMACY
DRUG PREPARATION AREA. ACCESS ABOVE EXISTING TILE CEILING IN THIS AREA IS
REQUIRED FOR 1ST FLOOR UTILITY WORK - REFER TO MEP DWGS. FOR SCOPE. GC SHALL
EMPLOY THE FOLLOWING INFECTION CONTROL PROTECTION MEASURES DURING
CONSTRUCTION IN OUTPATIENT PHARMACY AREAS AT ALL TIMES:
• WHEN REMOVING CEILING TILES, MOBILE HEPA FILTRATION CARTS MUST BE
UTILIZED THAT CREATE AN ENCLOSURE AROUND A SINGLE CEILING TILE
• WHEN REMOVING AN AREA OF CEILING TILES EQUAL TO OR EXCEEDING 10' X 10' AT
ANY ONE TIME, VISQUEEN ENCLOSURE MUST BE PROVIDED AROUND THE
PERIMETER OF THE AREA
ADDITIONALLY, A VA PHARMACIST MUST BE CONTACTED AND PRESENT BY LAW DURING ALL
CONSTRUCTION ACTIVITIES. THE GC AND THEIR EMPLOYEES/SUBCONTRACTORS SHALL
NOT BE PERMITTED FREE ACCESS INTO THE OUTPATIENT PHARMACY WITHOUT PROPER
PHARMACY SUPERVISION. WORK PERFORMED IN THE OUTPATIENT PHARMACY MUST
OCCUR OFF-HOURS WITHIN THE FOLLOWING TIMEFRAMES (WITH PHARMACY SUPERVISION
PRESENT):
• MON./TUES./WED./FRI. - 7 PM THRU 7 AM
• THURS. - 8 PM THRU 7 AM
• SAT./SUN. - 5 PM THRU 7 AM
79'-11" +/- EGRESS TRAVEL
DISTANCE/COMMON PATH OF
TRAVEL
F E
Areawell
BA110A
FE
FE
Mens
BAC330
Womens
BAC329
Conference Room
BAC286
Exam
BAC254
Exam
BAC255
Clean Supply
BAC259
Soiled Holding
BAC258
Office
BAC257
Records
BAC256
Waiting
BAC250
Triage
BAC251
Passage
BAC250B
Exam
BAC252
Exam
BAC253
Break Room
BAC283
Copy File/Work
BAC282Office
BAC281
Storage, File Room
BAC285
Elevator Lobby
BAC325
Corridor
BAC284
Anti-Coagulation Clinic Open Office
BAC280
LIFE SAFETY LEGEND:
TEMPORARY ZIP WALL PROTECTION TO BE PROVIDED AROUND CONSTRUCTION AREA PER VA
SAFETY STANDARDS. INSTALLATION OF ZIP WALL MAY NEED TO OCCUR AFTER RELOCATION OF
CASEWORK/FURNITURE. GC TO COORDINATE SEQUENCING OF INSTALL WITH COR
EXISTING/NEW 2 HOUR RATED FIRE BARRIER
EXISTING/NEW 1 HOUR RATED FIRE BARRIER
EXISTING/NEW 1 HOUR RATED SMOKE BARRIER
EXISTING/NEW O HOUR RATED SMOKE PARTITION
E EXIT
FE
FIRE EXTINGUISHER
EXIT SIGN LOCATION (DIRECTIONAL ARROWS MAY
OCCUR, SEE PLAN)
LIFE SAFETY GENERAL NOTES:
1. SEE COVER SHEET FOR APPLICABLE CODE INFORMATION. BUILDING IS CLASSIFIED AS A "NEW
AMBULATORY HEALTH CARE OCCUPANCY" PER NFPA 101 2018.
2. PROJECT SCOPE LINE IS INDICATED FOR GENERAL INTENT ONLY. CONTRACTOR WILL COMPLETE ALL WORK REGARDLESS IF IT IS LOCATED OUTSIDE OF PROJECT SCOPE AREA AS INDICATED ON ANY DRAWINGS
3. CONTRACTOR TO COVER OR ALTER EXIT SIGNS, OR TEMPORARILY RELOCATE EXISTING EXIT SIGNS WHICH, DUE TO CONSTRUCTION, TEMPORARILY DO NOT DEPICT EXIT PATHS AND/OR ARE IN THE WAY OF TEMPORARY CONSTRUCTION BARRIERS (TYP. OF ALL EXIT SIGNS IN OR BEYOND PROJECT AREA)
4. TRAVEL DISTANCES OVER 200' WILL REQUIRE INTERIM LIFE SAFETY MEASURES. COORDINATE WITH VA.
5. EXISTING FLOOR SLABS ARE 2 HR RATED. FOR ALL NEW CORE DRILLS/UTILITY PENETRATIONS, GC SHALL UTILIZE GROUND PENETRATING RADAR TO X-RAY EXISTING FLOOR SLAB AT PROPOSED, NEW PENETRATION LOCATION TO ENSURE THAT FLOOR SLAB REBAR STRUCTURE WILL NOT BE COMPROMISED, AND SHALL NOTIFY COR AND A/E TEAM OF ANY ISSUES DISCOVERED IN FIELD. GC SHALL PROVIDE NEW 2 HR RATED THRU-SLAB FIRESTOP ASSEMBLIES AT ALL PENETRATIONS. FOR EXISTING THRU-SLAB UTILITIES THAT ARE REMOVED AS A PART OF DEMOLITION SCOPE, GC SHALL PATCH CONC. SLAB FULLY WITH NEW CONCRETE
TO MATCH EXISTING
6. PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH NEW AND EXISTING FIRE/SMOKE RATED BARRIER WALLS AND FLOOR SLABS TO COMPLY WITH THE REQUIRED BARRIER RATINGS. PROVIDE
FIRESTOPPING AROUND TEN (10) PENETRATIONS LESS THAN 6 SQUARE INCHES AND FOUR (4)
PENETRATIONS BETWEEN 16 AND 36 SQUARE INCHES TO COMPLY WITH REQUIRED RATING NOT
ASSOCIATED WITH NEW WORK. LARGER OPENINGS SHALL BE BROUGHT TO THE ATTENTION OF THE COR.
GC SHALL SUBMIT UL LISTED METHODS FOR PATCHING ALL FIRE BARRIERS THAT MEET THE MINIMUM FIRE RATING REQUIREMENTS OF THE PENETRATING BARRIER AND ARE IN COMPLIANCE WITH THE OPENING SIZE
AS DICTATED BY THE ASSEMBLY.
7. TEMPORARY FIRE ALARMS IN CONSTRUCTION AREAS: GC SHALL PROVIDE TEMPORARY FIRE ALARMS IN ALL CONSTRUCTION AREAS THROUGHOUT THE CONSTRUCTION DURATION UNTIL SUCH TIME THAT NEW FIRE ALARM SYSTEM DEVICES ARE INSTALLED, TESTED, AND IN FULL OPERATION. HEAT DETECTION DEVICES SHALL BE UTILIZED AND SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND
COORDINATED THROUGH THE VA ELECTRICAL SHOP. GC SHALL COORDINATE WITH VA SAFETY
DEPARTMENT FOR ALL TEMPORARY FIRE ALARM INSTALLATIONS TO ENSURE COMPLIANCE WITH SAFETY
STANDARDS.
HAZARDOUS ROOM
EXISTING/NEW 2 HOUR RATED FIRE/SMOKE BARRIER
FIRE-RATED PLASTIC SHEETING/METAL STUD WALL TEMPORARY PARTITION WALL W/3'-0" X 7'-0"
SCWD DOOR FOR CONTRACTOR ACCESS ONLY. WALL AND DOOR TO BE REMOVED UPON
COMPLETION OF WORK U.N.O. PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY CONSTRUCTION. REFER TO "SOLID BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-601. SCHEDULE NOTE: CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE
PERFORMED AFTER NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR.
SEPARATE ALL OCCUPIED AREAS OF THE RENOVATION AREA BY TEMPORARY SMOKE-TIGHT
CONSTRUCTION PARTITIONS BUILT TO THE DECK ABOVE, AND FOR AREAS WITHOUT ACTIVE
SPRINKLER PROTECTION ON BOTH SIDES, THE PARTITION SHALL BER ONE-HOUR FIRE RATED.
PROJECT SCOPE BOUNDARY
PHASING DURATION & CONSTRUCTION TIMEFRAMES:
THE SCOPE OF WORK DESCRIBED IN THIS DRAWING PACKAGE REPRESENTS A MULTI-PHASED PROJECT THAT MUST BE UNDERTAKEN SIMULTANEOUSLY WITH THE FULL OCCUPANCY AND FUNCTION OF THE EXISTING
HOSPITAL. THE PROPOSED PHASING DURATING PLAN IS AS FOLLOWS:
PRE-CONSTRUCTION: 60 DAYS
PHASE I: 270 DAYS
VA ACTIVATION OF PHASE I: 45 DAYS
PHASE II: 90 DAYS
VA ACTIVATION OF PHASE II: 45 DAYS
PHASE III: 90 DAYS
VA ACTIVATION OF PHASE III: 45 DAYS
PHASE IV: 90 DAYS
VA ACTIVATION OF PHASE IV: 45 DAYS
PHASE V: 60 DAYS
VA ACTIVATION OF PHASE V: 45 DAYS
TOTAL TIMEFRAME: 885 DAYS*
*DEDUCT ALTERNATES, IF ACCEPTED, SHALL MODIFY THE CONTRACT TIMEFRAME AS FOLLOWS:
• DEDUCT ALTERNATE #1: PHASE I SHALL BE REDUCED (5) DAYS, FOR A NEW TOTAL TIMEFRAME OF 880
DAYS
• DEDUCT ALTERNATE #2: PHASE I SHALL BE REDUCED BY (7) DAYS, FOR A NEW TOTAL TIMEFRAME OF 878
DAYS
• DEDUCT ALTERNATE #3: PHASE I SHALL BE REDUCED BY (14) DAYS, FOR A NEW TOTAL TIMEFRAME OF 871
DAYS
THE FOLLOWING CONSTRUCTION SCHEDULE TIMEFRAMES SHALL APPLY TO THIS PROJECT:
CONSTRUCTION ACTIVITIES ARE PERMITTED TO OCCUR DURING REGULAR SHIFT HOURS, INCLUDING CONSTRUCTION OF THE ADDITION. TEMPORARY CONSTRUCTION BARRIERS MUST BE FULLY IN PLACE AND INTACT DURING CONSTRUCTION. CONTRACTORS, HOWEVER, SHALL NOT BE PERMITTED TO HAVE MATERIALS AND DELIVERIES DELIVERED OR TAKEN AWAY DURING REGULAR SHIFT HOURS, AND MUST COORDINATE SUCH ACTIVITIES TO TIMES WHEN THE PRIMARY CARE AND SPECIALTY CARE DEPARTMENTS ARE CLOSED.
COORDINATE TIMES WITH VA.
THE TIMEFRAMES IDENTIFIED ABOVE ARE IN REFERENCE TO NORMAL CONSTRUCTION ACTIVITIES AND, UNLESS
APPROVED BY VA COR, SHALL NOT APPLY TO WORK INCLUDING BUT NOT LIMITED TO:
• ABOVE-CEILING WORK IN THE BASEMENT LEVEL OUTPATIENT PHARMACY MUST OCCUR AFTER HOURS OR ON THE WEEKEND. REFER TO BASEMENT LEVEL LIFE SAFETY PLAN FOR APPLICABLE HOURS. VA
PHARMACIST MUST BE ON SITE DURING ALL ACTIVITIES IN THIS SPACE BY LAW.
• UTILITY SHUTDOWNS
• EXISTING MEP SYSTEM SHUTDOWNS
• WORK IN PUBLIC CORRIDORS/WAITING AREAS
• CUTTING OF FLOOR OPENINGS IN THE EXISTING BUILDING
• WORK OUTSIDE OF TEMPORARY CONSTRUCTION PARTITIONED AREAS, INCLUDING ACCESS OF CEILING
PLENUM SPACES IN FLOORS ABOVE OR BELOW CONSTRUCTION AREAS, AND REPLACEMENT OF EXISTING
FINISHES
• CONSTRUCTION OF TEMPORARY CONSTRUCTION BARRIERS
WORK IDENTIFIED ABOVE SHALL OCCUR EITHER IN THE EVENING SHIFT, OR IF REQUIRED BY THE VA, ON WEEKENDS. ALL CONSTRUCTION ACTIVITIES AND SCHEDULES MUST BE REVIEWED AND APPROVED BY VA COR.
REFER TO SPEC DIVISION 01 FOR GENERAL PROJECT REQUIREMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: NICK CARROZZA
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
E T
G
DE
I
RET
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
AT
E
I
T C
J.
O
O
FO
H
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C U s e rs
\d a v e
\D o c u m e n ts \E x p a n d P ri m a ry
C a re
R d a k a p la n
.r v t
/2
/2
:5
:3
P
M
BID ISSUE SUBMISSION
LS-0.1
BASEMENT LEVEL LIFE SAFETY PLAN - PHASE
I
EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
8.1.21 CJK DAK
SCALE: 1/8" = 1'-0"
BASEMENT LEVEL LIFE SAFETY PLAN - PHASE I
NORTH
Revisions: Date:
SCHEM. DESIGN SUBMISSION 3.15.19
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19
90% CD's SUBMISSION 8.9.19
FEC
F E
C
FEC
REF
REF. REF.
E
E
E
CONSTRUCTION AREA
E
FE
FE
F E
5'-0"
FE
F E
PROVIDE TEMPORARY FIRE
EXTINGUISHER CABINET IN TEMP.
CONSTRUCTION BARRIER DURING
PHASE I CONSTRUCTION. GC SHALL
RETAIN CABINET AND RELOCATE
DURING FUTURE PHASES
GC SHALL PROIVIDE MIN. 5'-0" WIDE
EGRESS PATH BETWEEN TEMPORARY
CONST. BARRIER AND EXISTING CORRIDOR
WALL
ALL EXISTING EGRESS PATHS IN PRIMARY CARE
DEPT. (DASHED LINES) TO REMAIN AS IS DURING
PHASE I CONSTRUCTION
REFER TO FUTURE PHASE LIFE
SAFETY PLANS FOR
CONTINUATION OF NEW SMOKE
BARRIER
CONSTRUCTION NOTE: SAFE EGRESS FROM THIS
EXISTING FIRST FLOOR STAIR DOOR MUST BE
MAINTAINED THROUGH CONSTRUCTION. NEW
CONSTRUCTION BARRIER FENCING SHALL BE
DESIGNED TO ACCOMMODATE SAFE EGRESS TRAVEL
TO SOUTH SIDE OF SITE WITHOUT TRAVEL THROUGH
CONSTRUCTION AREAS. SEE CIVIL DRAWINGS FOR
LAYOUT OF CONSTRUCTION FENCING
NEW SHAFT
NEW SHAFTS
Vestibule
1A101
Reception
1A102
Lobby
1A104
Waiting
1A105
Stair Alcove
1A106
Stair 1
1S1
Toilet
1A108
LPN Work Area
1A109
LPN Work Area
1A110
LPN Work Area
1A111
Soiled Utility
1A112
Electrical
1A113
Telecomm
1A114
Exam/Treatment Room
1A115
Exam/Treatment Room
1A116
Clean Utility
1A121
Exam/Treatment Room
1A122
Exam/Treatment Room
1A123
Exam/Treatment Room
1A124
Exam/Treatment Room
1A125
Exam/Treatment Room
1A126
Exam/Treatment Room
1A127
Exam/Treatment Room
1A128
Exam/Treatment Room
1A129
Exam/Treatment Room
1A130
Diabetes Education Office
1A132
Exam/Treatment Room
1A133
Exam/Treatment Room
1A134
Exam/Treatment Room
1A135
Social Work Office
1A136
Mas Reception 1
1A138
Mas Reception 2
1A139
Social Work Office
1A140
Exam/Treatment Room
1A141
Exam/Treatment Room
1A142
Exam/Treatment Room
1A143
Break Room
1A144
Exam/Treatment Room
1A148
Exam/Treatment Room
1A149
Exam/Treatment Room
1A150
Exam/Treatment Room
1A151
Exam/Treatment Room
1A152
Consult.
1A153A Men's
1A154
RR Alcove
1A155
Women's
1A156
Lead Techs Work Room
1A157
Exam/Treatment Room
1A158
Exam/Treatment Room
1A159
Exam/Treatment Room
1A160
Exam/Treatment Room
1A161
Exam/Treatment Room
1A162
Exam/Treatment Room
1A163
Exam/Treatment Room
1A164
Exam/Treatment Room
1A165
Exam/Treatment Room
1A166
Exam/Treatment Room
1A146
Stair 3
1S3
On-Call Room
1A169
Program Support Asst.
1A170
Nurse Manager
1A171
Staff Toilet
1A157A
Office
1A111A Office
1A111B
Lockers
1A111C
Corridor
1A100C
Corridor
1A100D
Corridor
1A100E
Corridor
1A100F
Corridor
1A100G
Waiting Room
1AC220
Reception
1AC221 Toilet
1AC222
Radiology 1
1AC223
Womens
1A214
Hospitality
1A215
Vending
1A216
Elevator Lobby
1A217
PCAS Waiting
1A218
Fast Track Exam
1AC288
Fast Track Exam
1AC290
Staff Lounge
1AC289B
GS6 Office
1A137A
GS9 Office
1A137B
Check-Out
1A137C
Stair 2
1S2
PACT Team Hub
- South
1A140
Exam/Treatment Room
1A136
Exam/Treatment Room
1A131
Check-Out
1A137D
Waiting Room
1A105
Consult.
1A153B
Exam/Treatment Room
1A132
Exam/Treatment Room
1A133
Exam/Treatment Room
1A134
Exam/Treatment Room
1A137
Exam/Treatment Room
1A138
Exam/Treatment Room
1A139
Nurse Managers Office
1A141
Director's Office
1A142
Precepting Room
1A143Elec. Closet
1A143A
Staff Toilet
1A144
Exam/Treatment Room
1A145
Stair 5
1S5 Stair 5 Vest.
1S5A
Corridor
1A100I
Exam/Treatment Room
1A117
Exam/Treatment Room
1A118
Exam/Treatment Room
1A119
Precepting Room
1A120
PACT Team Hub
- North
1A129
Break Room
1A126
Exam/Treatment Room
1A130A
Corridor
1A100H
86'-3" +/- EGRESS TRAVEL
DISTANCE/COMMON PATH OF
TRAVEL
Fire Alarm
1A126B
LIFE SAFETY LEGEND:
TEMPORARY ZIP WALL PROTECTION TO BE PROVIDED AROUND CONSTRUCTION AREA PER VA
SAFETY STANDARDS. INSTALLATION OF ZIP WALL MAY NEED TO OCCUR AFTER RELOCATION OF
CASEWORK/FURNITURE. GC TO COORDINATE SEQUENCING OF INSTALL WITH COR
EXISTING/NEW 2 HOUR RATED FIRE BARRIER
EXISTING/NEW 1 HOUR RATED FIRE BARRIER
EXISTING/NEW 1 HOUR RATED SMOKE BARRIER
EXISTING/NEW O HOUR RATED SMOKE PARTITION
E EXIT
FE
FIRE EXTINGUISHER
EXIT SIGN LOCATION (DIRECTIONAL ARROWS MAY
OCCUR, SEE PLAN)
LIFE SAFETY GENERAL NOTES:
1. SEE COVER SHEET FOR APPLICABLE CODE INFORMATION. BUILDING IS CLASSIFIED AS A "NEW
AMBULATORY HEALTH CARE OCCUPANCY" PER NFPA 101 2018.
2. PROJECT SCOPE LINE IS INDICATED FOR GENERAL INTENT ONLY. CONTRACTOR WILL COMPLETE ALL WORK REGARDLESS IF IT IS LOCATED OUTSIDE OF PROJECT SCOPE AREA AS INDICATED ON ANY DRAWINGS
3. CONTRACTOR TO COVER OR ALTER EXIT SIGNS, OR TEMPORARILY RELOCATE EXISTING EXIT SIGNS WHICH, DUE TO CONSTRUCTION, TEMPORARILY DO NOT DEPICT EXIT PATHS AND/OR ARE IN THE WAY OF TEMPORARY CONSTRUCTION BARRIERS (TYP. OF ALL EXIT SIGNS IN OR BEYOND PROJECT AREA)
4. TRAVEL DISTANCES OVER 200' WILL REQUIRE INTERIM LIFE SAFETY MEASURES. COORDINATE WITH VA.
5. EXISTING FLOOR SLABS ARE 2 HR RATED. FOR ALL NEW CORE DRILLS/UTILITY PENETRATIONS, GC SHALL UTILIZE GROUND PENETRATING RADAR TO X-RAY EXISTING FLOOR SLAB AT PROPOSED, NEW PENETRATION LOCATION TO ENSURE THAT FLOOR SLAB REBAR STRUCTURE WILL NOT BE COMPROMISED, AND SHALL NOTIFY COR AND A/E TEAM OF ANY ISSUES DISCOVERED IN FIELD. GC SHALL PROVIDE NEW 2 HR RATED THRU-SLAB FIRESTOP ASSEMBLIES AT ALL PENETRATIONS. FOR EXISTING THRU-SLAB UTILITIES THAT ARE REMOVED AS A PART OF DEMOLITION SCOPE, GC SHALL PATCH CONC. SLAB FULLY WITH NEW CONCRETE
TO MATCH EXISTING
6. PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH NEW AND EXISTING FIRE/SMOKE RATED BARRIER WALLS AND FLOOR SLABS TO COMPLY WITH THE REQUIRED BARRIER RATINGS. PROVIDE
FIRESTOPPING AROUND TEN (10) PENETRATIONS LESS THAN 6 SQUARE INCHES AND FOUR (4)
PENETRATIONS BETWEEN 16 AND 36 SQUARE INCHES TO COMPLY WITH REQUIRED RATING NOT
ASSOCIATED WITH NEW WORK. LARGER OPENINGS SHALL BE BROUGHT TO THE ATTENTION OF THE COR.
GC SHALL SUBMIT UL LISTED METHODS FOR PATCHING ALL FIRE BARRIERS THAT MEET THE MINIMUM FIRE RATING REQUIREMENTS OF THE PENETRATING BARRIER AND ARE IN COMPLIANCE WITH THE OPENING SIZE
AS DICTATED BY THE ASSEMBLY.
7. TEMPORARY FIRE ALARMS IN CONSTRUCTION AREAS: GC SHALL PROVIDE TEMPORARY FIRE ALARMS IN ALL CONSTRUCTION AREAS THROUGHOUT THE CONSTRUCTION DURATION UNTIL SUCH TIME THAT NEW FIRE ALARM SYSTEM DEVICES ARE INSTALLED, TESTED, AND IN FULL OPERATION. HEAT DETECTION DEVICES SHALL BE UTILIZED AND SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND
COORDINATED THROUGH THE VA ELECTRICAL SHOP. GC SHALL COORDINATE WITH VA SAFETY
DEPARTMENT FOR ALL TEMPORARY FIRE ALARM INSTALLATIONS TO ENSURE COMPLIANCE WITH SAFETY
STANDARDS.
HAZARDOUS ROOM
EXISTING/NEW 2 HOUR RATED FIRE/SMOKE BARRIER
FIRE-RATED PLASTIC SHEETING/METAL STUD WALL TEMPORARY PARTITION WALL W/3'-0" X 7'-0"
SCWD DOOR FOR CONTRACTOR ACCESS ONLY. WALL AND DOOR TO BE REMOVED UPON
COMPLETION OF WORK U.N.O. PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY CONSTRUCTION. REFER TO "SOLID BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-601. SCHEDULE NOTE: CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE
PERFORMED AFTER NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR.
SEPARATE ALL OCCUPIED AREAS OF THE RENOVATION AREA BY TEMPORARY SMOKE-TIGHT
CONSTRUCTION PARTITIONS BUILT TO THE DECK ABOVE, AND FOR AREAS WITHOUT ACTIVE
SPRINKLER PROTECTION ON BOTH SIDES, THE PARTITION SHALL BER ONE-HOUR FIRE RATED.
PROJECT SCOPE BOUNDARY
PHASING DURATION & CONSTRUCTION TIMEFRAMES:
THE SCOPE OF WORK DESCRIBED IN THIS DRAWING PACKAGE REPRESENTS A MULTI-PHASED PROJECT THAT MUST BE UNDERTAKEN SIMULTANEOUSLY WITH THE FULL OCCUPANCY AND FUNCTION OF THE EXISTING
HOSPITAL. THE PROPOSED PHASING DURATING PLAN IS AS FOLLOWS:
PRE-CONSTRUCTION: 60 DAYS
PHASE I: 270 DAYS
VA ACTIVATION OF PHASE I: 45 DAYS
PHASE II: 90 DAYS
VA ACTIVATION OF PHASE II: 45 DAYS
PHASE III: 90 DAYS
VA ACTIVATION OF PHASE III: 45 DAYS
PHASE IV: 90 DAYS
VA ACTIVATION OF PHASE IV: 45 DAYS
PHASE V: 60 DAYS
VA ACTIVATION OF PHASE V: 45 DAYS
TOTAL TIMEFRAME: 885 DAYS*
*DEDUCT ALTERNATES, IF ACCEPTED, SHALL MODIFY THE CONTRACT TIMEFRAME AS FOLLOWS:
• DEDUCT ALTERNATE #1: PHASE I SHALL BE REDUCED (5) DAYS, FOR A NEW TOTAL TIMEFRAME OF 880
DAYS
• DEDUCT ALTERNATE #2: PHASE I SHALL BE REDUCED BY (7) DAYS, FOR A NEW TOTAL TIMEFRAME OF 878
DAYS
• DEDUCT ALTERNATE #3: PHASE I SHALL BE REDUCED BY (14) DAYS, FOR A NEW TOTAL TIMEFRAME OF 871
DAYS
THE FOLLOWING CONSTRUCTION SCHEDULE TIMEFRAMES SHALL APPLY TO THIS PROJECT:
CONSTRUCTION ACTIVITIES ARE PERMITTED TO OCCUR DURING REGULAR SHIFT HOURS, INCLUDING CONSTRUCTION OF THE ADDITION. TEMPORARY CONSTRUCTION BARRIERS MUST BE FULLY IN PLACE AND INTACT DURING CONSTRUCTION. CONTRACTORS, HOWEVER, SHALL NOT BE PERMITTED TO HAVE MATERIALS AND DELIVERIES DELIVERED OR TAKEN AWAY DURING REGULAR SHIFT HOURS, AND MUST COORDINATE SUCH ACTIVITIES TO TIMES WHEN THE PRIMARY CARE AND SPECIALTY CARE DEPARTMENTS ARE CLOSED.
COORDINATE TIMES WITH VA.
THE TIMEFRAMES IDENTIFIED ABOVE ARE IN REFERENCE TO NORMAL CONSTRUCTION ACTIVITIES AND, UNLESS
APPROVED BY VA COR, SHALL NOT APPLY TO WORK INCLUDING BUT NOT LIMITED TO:
• ABOVE-CEILING WORK IN THE BASEMENT LEVEL OUTPATIENT PHARMACY MUST OCCUR AFTER HOURS OR ON THE WEEKEND. REFER TO BASEMENT LEVEL LIFE SAFETY PLAN FOR APPLICABLE HOURS. VA
PHARMACIST MUST BE ON SITE DURING ALL ACTIVITIES IN THIS SPACE BY LAW.
• UTILITY SHUTDOWNS
• EXISTING MEP SYSTEM SHUTDOWNS
• WORK IN PUBLIC CORRIDORS/WAITING AREAS
• CUTTING OF FLOOR OPENINGS IN THE EXISTING BUILDING
• WORK OUTSIDE OF TEMPORARY CONSTRUCTION PARTITIONED AREAS, INCLUDING ACCESS OF CEILING
PLENUM SPACES IN FLOORS ABOVE OR BELOW CONSTRUCTION AREAS, AND REPLACEMENT OF EXISTING
FINISHES
• CONSTRUCTION OF TEMPORARY CONSTRUCTION BARRIERS
WORK IDENTIFIED ABOVE SHALL OCCUR EITHER IN THE EVENING SHIFT, OR IF REQUIRED BY THE VA, ON WEEKENDS. ALL CONSTRUCTION ACTIVITIES AND SCHEDULES MUST BE REVIEWED AND APPROVED BY VA COR.
REFER TO SPEC DIVISION 01 FOR GENERAL PROJECT REQUIREMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: NICK CARROZZA
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
E T
G
DE
I
RET
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
AT
E
I
T C
J.
O
O
FO
H
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C U s e rs
\d a v e
\D o c u m e n ts \E x p a n d P ri m a ry
C a re
R d a k a p la n
.r v t
/2
/2
:5
:4
P
M
BID ISSUE SUBMISSION
LS-1.1
1ST FLOOR LIFE SAFETY PLAN - PHASE I EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
8.1.21 CJK DAK
SCALE: 1/8" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN - PHASE I
NORTH
TOTAL EXAM ROOMS AVAILABLE FOR USE DURING PHASE I CONSTRUCTION = 34
Revisions: Date:
SCHEM. DESIGN SUBMISSION 3.15.19
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19
90% CD's SUBMISSION 8.9.19
F E
C
FEC
FEC
REF
REF. REF.
LIFE SAFETY LEGEND:
TEMPORARY ZIP WALL PROTECTION TO BE PROVIDED AROUND CONSTRUCTION AREA PER VA
SAFETY STANDARDS. INSTALLATION OF ZIP WALL MAY NEED TO OCCUR AFTER RELOCATION OF
CASEWORK/FURNITURE. GC TO COORDINATE SEQUENCING OF INSTALL WITH COR
EXISTING/NEW 2 HOUR RATED FIRE BARRIER
EXISTING/NEW 1 HOUR RATED FIRE BARRIER
EXISTING/NEW 1 HOUR RATED SMOKE BARRIER
EXISTING/NEW O HOUR RATED SMOKE PARTITION
E EXIT
FE
FIRE EXTINGUISHER
EXIT SIGN LOCATION (DIRECTIONAL ARROWS MAY
OCCUR, SEE PLAN)
LIFE SAFETY GENERAL NOTES:
1. SEE COVER SHEET FOR APPLICABLE CODE INFORMATION. BUILDING IS CLASSIFIED AS A "NEW
AMBULATORY HEALTH CARE OCCUPANCY" PER NFPA 101 2018.
2. PROJECT SCOPE LINE IS INDICATED FOR GENERAL INTENT ONLY. CONTRACTOR WILL COMPLETE ALL WORK REGARDLESS IF IT IS LOCATED OUTSIDE OF PROJECT SCOPE AREA AS INDICATED ON ANY DRAWINGS
3. CONTRACTOR TO COVER OR ALTER EXIT SIGNS, OR TEMPORARILY RELOCATE EXISTING EXIT SIGNS WHICH, DUE TO CONSTRUCTION, TEMPORARILY DO NOT DEPICT EXIT PATHS AND/OR ARE IN THE WAY OF TEMPORARY CONSTRUCTION BARRIERS (TYP. OF ALL EXIT SIGNS IN OR BEYOND PROJECT AREA)
4. TRAVEL DISTANCES OVER 200' WILL REQUIRE INTERIM LIFE SAFETY MEASURES. COORDINATE WITH VA.
5. EXISTING FLOOR SLABS ARE 2 HR RATED. FOR ALL NEW CORE DRILLS/UTILITY PENETRATIONS, GC SHALL UTILIZE GROUND PENETRATING RADAR TO X-RAY EXISTING FLOOR SLAB AT PROPOSED, NEW PENETRATION LOCATION TO ENSURE THAT FLOOR SLAB REBAR STRUCTURE WILL NOT BE COMPROMISED, AND SHALL NOTIFY COR AND A/E TEAM OF ANY ISSUES DISCOVERED IN FIELD. GC SHALL PROVIDE NEW 2 HR RATED THRU-SLAB FIRESTOP ASSEMBLIES AT ALL PENETRATIONS. FOR EXISTING THRU-SLAB UTILITIES THAT ARE REMOVED AS A PART OF DEMOLITION SCOPE, GC SHALL PATCH CONC. SLAB FULLY WITH NEW CONCRETE
TO MATCH EXISTING
6. PROVIDE FIRESTOPPING AT ALL PENETRATIONS THROUGH NEW AND EXISTING FIRE/SMOKE RATED BARRIER WALLS AND FLOOR SLABS TO COMPLY WITH THE REQUIRED BARRIER RATINGS. PROVIDE
FIRESTOPPING AROUND TEN (10) PENETRATIONS LESS THAN 6 SQUARE INCHES AND FOUR (4)
PENETRATIONS BETWEEN 16 AND 36 SQUARE INCHES TO COMPLY WITH REQUIRED RATING NOT
ASSOCIATED WITH NEW WORK. LARGER OPENINGS SHALL BE BROUGHT TO THE ATTENTION OF THE COR.
GC SHALL SUBMIT UL LISTED METHODS FOR PATCHING ALL FIRE BARRIERS THAT MEET THE MINIMUM FIRE RATING REQUIREMENTS OF THE PENETRATING BARRIER AND ARE IN COMPLIANCE WITH THE OPENING SIZE
AS DICTATED BY THE ASSEMBLY.
7. TEMPORARY FIRE ALARMS IN CONSTRUCTION AREAS: GC SHALL PROVIDE TEMPORARY FIRE ALARMS IN ALL CONSTRUCTION AREAS THROUGHOUT THE CONSTRUCTION DURATION UNTIL SUCH TIME THAT NEW FIRE ALARM SYSTEM DEVICES ARE INSTALLED, TESTED, AND IN FULL OPERATION. HEAT DETECTION DEVICES SHALL BE UTILIZED AND SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND
COORDINATED THROUGH THE VA ELECTRICAL SHOP. GC SHALL COORDINATE WITH VA SAFETY
DEPARTMENT FOR ALL TEMPORARY FIRE ALARM INSTALLATIONS TO ENSURE COMPLIANCE WITH SAFETY
STANDARDS.
HAZARDOUS ROOM
EXISTING/NEW 2 HOUR RATED FIRE/SMOKE BARRIER
FIRE-RATED PLASTIC SHEETING/METAL STUD WALL TEMPORARY PARTITION WALL W/3'-0" X 7'-0"
SCWD DOOR FOR CONTRACTOR ACCESS ONLY. WALL AND DOOR TO BE REMOVED UPON
COMPLETION OF WORK U.N.O. PATCH/REPAIR EXISTING CONDITIONS AS REQUIRED UPON REMOVAL OF ALL TEMPORARY CONSTRUCTION. REFER TO "SOLID BARRIER" TYPICAL TEMPORARY PARTITION DETAIL ON SHEET AS-601. SCHEDULE NOTE: CONSTRUCTION OF TEMPORARY BARRIERS SHALL BE
PERFORMED AFTER NORMAL BUSINESS HOURS UNLESS OTHERWISE APPROVED BY THE COR.
SEPARATE ALL OCCUPIED AREAS OF THE RENOVATION AREA BY TEMPORARY SMOKE-TIGHT
CONSTRUCTION PARTITIONS BUILT TO THE DECK ABOVE, AND FOR AREAS WITHOUT ACTIVE
SPRINKLER PROTECTION ON BOTH SIDES, THE PARTITION SHALL BER ONE-HOUR FIRE RATED.
PROJECT SCOPE BOUNDARY
Nurse Manager
1A171
Program Support Ass't
1A170
On-Call Room
1A169
Staff Toilet
1A157A
Mental Health Consult.
1A167
Mental Health Consult.
1A166
Mental Health Consult.
1A165
Mental Health Consult./Diabetes
Education
1A164
Exam/Treatment Room
1A163
Exam/Treatment Room
1A162
Exam/Treatment Room
1A161
Exam/Treatment Room
1A150
Exam/Treatment Room
1A149
Exam/Treatment Room
1A143
Exam/Treatment Room
1A142
Social Work Office
1A140
Social Work Office
1A136 GS6/GS9 Office
1A110
Mas. Reception 1
1A138
Mas Reception 2
1A139
SMA Conference Room
1A111
SMA Storage Room
1A111A
Exam/Treatment Room
1A112
Toilet
1A108 Stair Alcove
1A106
Stair 1
1S1 Electrical
1A113
Telecomm
1A114
Exam/Treatment Room
1A125
Exam/Treatment Room
1A126
Exam/Treatment Room
1A128
Corridor
1A100A
Exam/Treatment Room
1A122
Exam/Treatment Room
1A129
Exam/Treatment Room
1A133
Precepting Room
1A120
Exam/Treatment Room
1A131
Exam/Treatment Room
1A132
Exam/Treatment Room
1A133
Exam/Treatment Room
1A134
Corridor
1A100H
Exam/Treatment Room
1A136
Exam/Treatment Room
1A137
Exam/Treatment Room
1A138
Exam/Treatment Room
1A139
Stair 5 Vest.
1S5A
Stair 5
1S5
PACT Team Hub
- North
1A129
PACT Team Hub
- South
1A140 Exam/Treatment
Room
1A147
Exam/Treatment Room
1A148
Soiled Holding
1A153
Exam/Treatment Room
1A146
Corridor
1A100I
Storage
1A152
Stair 3
1S3Corridor
1A100F
Corridor
1A100G
Consult.
1A153B Staff Toilet
1A144
Exam/Treatment Room
1A145
Precepting Room
1A143
Director's Office
1A142
Nurse Managers Office
1A141
Corridor
1A100D
Corridor
1A100A
Corridor
1A100E
Diabetes Education Office
1A132
Consult.
1A153A
Exam/Treatment Room
1A151
Clean Utility
1A157
Exam/Treatment Room
1A127
Exam/Treatment Room
1A124
Exam/Treatment Room
1A123
Exam/Treatment Room
1A115
Exam/Treatment Room
1A116
Exam/Treatment Room
1A117
Exam/Treatment Room
1A118
Exam/Treatment Room
1A119
Clean Utility
1A121
Exam/Treatment Room
1A130
Check-Out
1A137C
Exam/Treatment Room
1A134
Exam/Treatment Room
1A135
Exam/Treatment Room
1A141
Break Room
1A144
FE
CONSTRUCTION AREA
CONSTRUCTION AREA
E
E
E
D E
A D
E N
D
5'-0"
GC SHALL PROVIDE
MIN. 5'-0" WIDE
EGRESS PATH
BETWEEN
TEMPORARY CONST.
BARRIER AND
EXISTING CORRIDOR
WALL
PROPOSED INTERIM
EGRESS PATHS IN
PRIMARY CARE DEPT.
(DASHED LINES)
FE
FE
FE
PROVIDE TEMPORARY FIRE
EXITINGUISHER CABINET IN TEMP.
CONST. BARRIER DURING PHASE II
CONSTRUCTION (RELOCATED FROM
PHASE I). GC SHALL RETAIN CABINET
AND RELOCATE DURING FUTURE
PHASES
F E
SPECIAL PHASING NOTE: EXAMS
ROOMS 1A145 AND 1A146 WILL NOT
BE IN USE BY PATIENTS DURING
PHASE II. DOORS FACING
CONSTRUCTION AREAS SHALL BE
FULLY SEALED BY GC AND
PROTECTED FROM
CONSTRUCTION ACTIVITIES
REFER TO FUTURE PHASE LIFE SAFETY PLANS
FOR CONTINUATION OF NEW SMOKE BARRIER
GC ACCESS
DOOR
GC ACCESS
DOOR
MAINTAIN ACCESS TO STAFF
TOILET ROOM DURING THIS
PHASE
Corridor
1A100C
5'-0"
SPECIAL PHASING NOTE: THE DEMOLITION OF THE
ELECTRICAL ROOM WALL AND EX. SOILED UTILITY
ROOM SHALL OCCUR AT THE END OF PHASE II. SEE
PHASE II DEMO PLAN
Elec. Closet
1A143A
Exam/Treatment Room
1A130A
Break Room
1A126
Corridor
1A100C
17'-5"
6'-10"
Mens
1A154
Womens
1A156
RR Alcove
1A155
Elevator Lobby
1A217
Waiting Room
1A105
Lobby
1A104
Reception
1A102
PCAS Waiting
1A218
Vestibule
1A101
Fast Track Exam
1AC290
Fast Track Exam
1AC288
Staff Lounge
1AC289B
Waiting Room
1AC220
Reception
1AC221 Toilet
1AC222 Radiology 1
1AC223
Vending
1A216
Hospitality
1A215
Fire Alarm
1A126B
PHASING DURATION & CONSTRUCTION TIMEFRAMES:
THE SCOPE OF WORK DESCRIBED IN THIS DRAWING PACKAGE REPRESENTS A MULTI-PHASED PROJECT THAT MUST BE UNDERTAKEN SIMULTANEOUSLY WITH THE FULL OCCUPANCY AND FUNCTION OF THE EXISTING
HOSPITAL. THE PROPOSED PHASING DURATING PLAN IS AS FOLLOWS:
PRE-CONSTRUCTION: 60 DAYS
PHASE I: 270 DAYS
VA ACTIVATION OF PHASE I: 45 DAYS
PHASE II: 90 DAYS
VA ACTIVATION OF PHASE II: 45 DAYS
PHASE III: 90 DAYS
VA ACTIVATION OF PHASE III: 45 DAYS
PHASE IV: 90 DAYS
VA ACTIVATION OF PHASE IV: 45 DAYS
PHASE V: 60 DAYS
VA ACTIVATION OF PHASE V: 45 DAYS
TOTAL TIMEFRAME: 885 DAYS*
*DEDUCT ALTERNATES, IF ACCEPTED, SHALL MODIFY THE CONTRACT TIMEFRAME AS FOLLOWS:
• DEDUCT ALTERNATE #1: PHASE I SHALL BE REDUCED (5) DAYS, FOR A NEW TOTAL TIMEFRAME OF 880
DAYS
• DEDUCT ALTERNATE #2: PHASE I SHALL BE REDUCED BY (7) DAYS, FOR A NEW TOTAL TIMEFRAME OF 878
DAYS
• DEDUCT ALTERNATE #3: PHASE I SHALL BE REDUCED BY (14) DAYS, FOR A NEW TOTAL TIMEFRAME OF 871
DAYS
THE FOLLOWING CONSTRUCTION SCHEDULE TIMEFRAMES SHALL APPLY TO THIS PROJECT:
CONSTRUCTION ACTIVITIES ARE PERMITTED TO OCCUR DURING REGULAR SHIFT HOURS, INCLUDING CONSTRUCTION OF THE ADDITION. TEMPORARY CONSTRUCTION BARRIERS MUST BE FULLY IN PLACE AND INTACT DURING CONSTRUCTION. CONTRACTORS, HOWEVER, SHALL NOT BE PERMITTED TO HAVE MATERIALS AND DELIVERIES DELIVERED OR TAKEN AWAY DURING REGULAR SHIFT HOURS, AND MUST COORDINATE SUCH ACTIVITIES TO TIMES WHEN THE PRIMARY CARE AND SPECIALTY CARE DEPARTMENTS ARE CLOSED.
COORDINATE TIMES WITH VA.
THE TIMEFRAMES IDENTIFIED ABOVE ARE IN REFERENCE TO NORMAL CONSTRUCTION ACTIVITIES AND, UNLESS
APPROVED BY VA COR, SHALL NOT APPLY TO WORK INCLUDING BUT NOT LIMITED TO:
• ABOVE-CEILING WORK IN THE BASEMENT LEVEL OUTPATIENT PHARMACY MUST OCCUR AFTER HOURS OR ON THE WEEKEND. REFER TO BASEMENT LEVEL LIFE SAFETY PLAN FOR APPLICABLE HOURS. VA
PHARMACIST MUST BE ON SITE DURING ALL ACTIVITIES IN THIS SPACE BY LAW.
• UTILITY SHUTDOWNS
• EXISTING MEP SYSTEM SHUTDOWNS
• WORK IN PUBLIC CORRIDORS/WAITING AREAS
• CUTTING OF FLOOR OPENINGS IN THE EXISTING BUILDING
• WORK OUTSIDE OF TEMPORARY CONSTRUCTION PARTITIONED AREAS, INCLUDING ACCESS OF CEILING
PLENUM SPACES IN FLOORS ABOVE OR BELOW CONSTRUCTION AREAS, AND REPLACEMENT OF EXISTING
FINISHES
• CONSTRUCTION OF TEMPORARY CONSTRUCTION BARRIERS
WORK IDENTIFIED ABOVE SHALL OCCUR EITHER IN THE EVENING SHIFT, OR IF REQUIRED BY THE VA, ON WEEKENDS. ALL CONSTRUCTION ACTIVITIES AND SCHEDULES MUST BE REVIEWED AND APPROVED BY VA COR.
REFER TO SPEC DIVISION 01 FOR GENERAL PROJECT REQUIREMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: NICK CARROZZA
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Louis Stokes Cleveland
VA Medical Center
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
E T
G
DE
I
RET
S
HCRA
I
KACZMAR
STANLEY
NO. 4988
T
E R
S
AT
E
I
T C
J.
O
O
FO
H
1468 WEST 9TH STREET #400
CLEVELAND, OH 44113
P. 216.687.1555 F. 216.687.1558
STRUCTURAL ENGINEERING:
THORSON BAKER + ASSOCIATES
3030 WEST STREETSBORO RD.
RICHFIELD, OH 44286
P. 330.659.6688
CIVIL/MECH./ELEC./PLUMBING ENGINEERING:
SCHEESER BUCKLEY MAYFIELD, LLC
1540 CORPORATE WOODS PKWY.
UNIONTOWN, OH 44111
P. 330.526.2700
COST ESTIMATING:
MCGUINESS UNLIMITED, INC.
15724 STILLWOOD AVE.
CLEVELAND, OH 44111
P. 440.667.5120
LANDSCAPE ARCHITECTURE:
JAMES S. MCKNIGHT
P.O. BOX 14158
CLEVELAND, OH 44114
P. 216.952.2408
HAZARDOUS MATERIALS
ASSESSMENT:
STEPHEN J. SEBESTA &
ASSOCIATES, INC.
30628 DETROIT RD., NO. 258
WESTLAKE, OH 44145
P. 216.781.0060
C U s e rs
\d a v e
\D o c u m e n ts \E x p a n d P ri m a ry
C a re
R d a k a p la n
.r v t
/2
/2
:5
:4
P
M
BID ISSUE SUBMISSION
LS-1.2
FIRST FLOOR LIFE SAFETY PLAN - PHASE II EXPAND PRIMARY CARE FOR
PACT REALIGNMENT
10701 EAST BLVD. CLEVELAND, OHIO
541-376
8.1.21 Checker Author
SCALE: 1/8" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN - PHASE II
NORTH
TOTAL EXAM ROOMS AVAILABLE FOR USE DURING PHASE II CONSTRUCTION = 30 (INCL. DIABETES EDUCATION OFFICE)
Revisions: Date:
SCHEM. DESIGN SUBMISSION 3.15.19
DD SUBMISSION 5.3.19
65% CD's SUBMISSION 6.14.19
90% CD's SUBMISSION 8.9.19
E
C
FEC
FEC
FEC
R E
F
REF. REF.
F E
C
Mas. Reception 1
1A138
Mas Reception 2
1A139
GS6/GS9 Office
1A110
SMA Conference Room
1A111
Electrical
1A113
Telecomm
1A114
Stair Alcove
1A106
Toilet
1A108
Stair 1
1S1
Waiting Room
1A105
Mens
1A154
Womens
1A156
RR Alcove
1A155
Nurse Manager
1A171
Program Support Ass't
1A170
Corridor
1A100G
Exam/Treatment Room
1A112 SMA Storage
Room
1A111A
Exam/Treatment Room
1A125
Exam/Treatment Room
1A126
Exam/Treatment Room
1A117
Exam/Treatment Room
1A118
Exam/Treatment Room
1A128
Exam/Treatment Room
1A120
Exam/Treatment Room
1A121
Exam/Treatment Room
1A122
Exam/Treatment Room
1A129
Exam/Treatment Room
1A122
Corridor
1A100A
Exam/Treatment Room
1A127
PACT Team Hub
- North
1A129
Exam/Treatment Room
1A130
Exam/Treatment Room
1A131
Exam/Treatment Room
1A132
Exam/Treatment Room
1A133
Exam/Treatment Room
1A134
Exam/Treatment Room
1A135
Exam/Treatment Room
1A136
Exam/Treatment Room
1A137
Exam/Treatment Room
1A138
Exam/Treatment Room
1A139
PACT Team Hub
- South
1A140Exam/Treatment Room
1A147
Exam/Treatment Room
1A148 Nurse Managers Office
1A141
Director's Office
1A142
Precepting Room
1A143Elec. Closet
1A143A
Staff Toilet
1A144
Exam/Treatment Room
1A145
Exam/Treatment Room
1A146
Soiled Holding
1A153
Storage
1A152
Exam/Treatment Room
1A149
Exam/Treatment Room
1A150
Exam/Treatment Room
1A151
Consult.
1A153B
Exam/Treatment Room
1A161
Exam/Treatment Room
1A162
Exam/Treatment Room
1A163
Mental Health Consult./Diabetes
Education
1A164
Mental Health Consult.
1A165
Mental Health Consult.
1A166
Mental Health Consult.
1A167
Staff Toilet
1A157A
On-Call Room
1A169
Stair 5
1S5Stair 5 Vest.
1S5A
Stair 3
1S3
Corridor
1A100D
Corridor
1A100A
Corridor
1A100E
Corridor
1A100H
Corridor
1A100F
Corridor
1A100IClean Utility
1A157
Meds. Alcove
1A121A
Exam/Treatment Room
1A130A
Vestibule
1A101
Reception
1A102
Lobby
1A104
Waiting
1A105
Exam/Treatment Room
1A115
Exam/Treatment Room
1A116
Exam/Treatment Room
1A117
Exam/Treatment Room
1A118
Exam/Treatment Room
1A123
Exam/Treatment Room
1A124
Exam/Treatment Room
1A127
PACT Team Hub
- West
1A119
Consult.
1A153A
Waiting Room
1AC220
Reception
1AC221 Toilet
1AC222
Radiology 1
1AC223
Womens
1A214
Hospitality
1A215
Vending
1A216
Elevator Lobby
1A217
PCAS Waiting
1A218
Fast Track Exam
1AC288
Fast Track Exam
1AC290
Staff Lounge
1AC289B
Stair 2
1S2
Corridor
1A100C
Check-Out
1A137C
CONSTRUCTION AREA
C O
N S
T R
U C
T
IO
N A
R E
A
FE
E
E
E
SMOKE COMPARTMENT 'A'
9,229 SF
SMOKE COMP. 'B'
5,992 SF
SMOKE COMPARTMENT 'A'
9,229 SF
SMOKE COMPARTMENT 'B'
5,992 SF
FE
F E
FE
F E
PROVIDE TEMPORARY FIRE EXITINGUISHER
CABINET IN TEMP. CONST. BARRIER DURING
PHASE III CONSTRUCTION (RELOCATED FROM
PHASES I & II). GC SHALL RETAIN CABINET
AND RELOCATE DURING FUTURE PHASES
SPECIAL PHASING NOTE: AREA OF PHASE III CONSTRUCTION
HATCHED IN GRAY IS INTENDED TO BE BUILT LAST, AFTER
TEMPORARY CONST. BARRIERS ARE REMOVED. INTENT IS TO
MAINTAIN EGRESS PATH IN CORRIDOR TO NEW STAIR 5 AS
INDICATED UNTIL SUCH TIME THAT CONST. BARRIERS CAN BE
REMOVED. REMAINING PORTION OF EXAM ROOM 1A130
CONSTRUCTION IN GRAY AREA SHALL THEN BE
CONSTRUCTED. COORD. PROTECTION REQUIREMENTS WITH
VA COR AND VA SAFETY
EMPLOYEES SHALL NOT
HAVE ACCESS TO WEST
PACT ENTRY DOOR
DURING PHASE III.
EMPLOYEES WILL HAVE
ACCESS TO DOOR OFF
CORRIDOR 1A100H
9'-11"
5'-0"
GC SHALL PROVIDE
MIN. 5'-0" WIDE
EGRESS PATH
BETWEEN
TEMPORARY CONST.
BARRIER AND
EXISTING CORRIDOR
WALL
DEAD END
44'-2"
PROPOSED INTERIM EGRESS
PATHS IN PRIMARY CARE
DEPT. (DASHED LINES)
FE
FE
CURVED DASHED LINE INDICATES 83'-8"
+/- COMMON PATH OF TRAVEL
GC ACCESS
DOORS
(SHELL) (SHELL)
(SHELL)
Corridor
1A100C
Corridor
1A100B
Exam/Treatment Room
1A128
Staff/Patient Toilet
1A128A
Locker Area
1A126A
Break Room
1A126
GC SHALL COORD. TIMING OF CUTTING NEW
CONNECTING OPENING TO BREAK ROOM TO BE
TOWARDS THE END OF PHASE III SO AS TO
MINIMIZE TIMEFRAME TO SEPARATE THE BREAK
ROOM FROM TEMPORARY BARRIER AS SHOWN
'A '. 'B
Fire Alarm
1A126B
Storage
1A129A
LIFE…