This document is an asbestos survey report for the Iowa City VA Health Care System's Dialysis Clinic renovation project. Conducted by Landmark Environmental, LLC on November 19, 2024, the survey covered the 5th floor south (5S) and 5th floor west (5W) areas, collecting 84 bulk asbestos samples that were analyzed into 95 individual sample layers. The survey identified two asbestos-containing materials: gray adhesive on plaster (10 square feet) and 12" x 12" white and gray floor tile (100 square feet). Additionally, fire doors and electric panels were assumed to contain asbestos.
The report recommends removing identified asbestos-containing materials in accordance with accompanying specifications, with contractors required to stop work and assume materials contain asbestos if untested materials are discovered during renovation. The survey was part of a larger project (VA Project Number 636A8-24-001) to renovate the Dialysis Clinic, which involves preparing a temporary dialysis clinic and then renovating 5,000 square feet of the existing clinic. The survey was conducted to ensure safe renovation practices and compliance with environmental regulations, with samples analyzed by EMSL Analytical, Inc. using polarized light microscopy.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Anderson Engineering of Minnesota, LLC
13605 1st Avenue North Plymouth, MN 55441
Phone: 763-412-4000 Fax: 763-412-4090
Prepared in association with the following:
IMEG Corp
2882 106th Street Des Moines, IA 50322 Phone: 515-334-9906
Renovate Dialysis
VA PROJECT NUMBER: 636A8-24-001
601 HWY 6 West Iowa City, IA 52246
TECHNICAL SPECIFICATIONS
Volume 3: APPENDICES
ANDERSON ENGINEERING OF MN, LLC
Project Number: 17909
Issue for Construction Documents
April 24, 2025
Prepared for:
ANDERSON ENGINEERING
13605 - 1ST AVENUE NORTH
PLYMOUTH, MN
December 23, 2024
Pre-Renovation Asbestos Survey Iowa City VA Health Care System – Renovate Dialysis Building 1 – 5th Floor Iowa City, Iowa
Landmark Environmental, LLC 9555 James Avenue South, Suite 262 | Bloomington, MN 55431 | Phone: 952-295-9400 | www.landmarkenv.com
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
Asbestos Inspection Report
Iowa City VA Health Care System – Renovate Dialysis
Building 1 – 5th Floor
Iowa City, Iowa
1.0 Executive Summary
2.0 Introduction
3.0 Sampling Methods and Analysis
4.0 Asbestos-Containing Material Assessment
5.0 Findings
6.0 Signatures of Environmental Professional(s)
Appendices
Appendix A Asbestos Certificates
Appendix B Building Diagrams with Sample Locations
Appendix C Asbestos-Containing Materials Physical Assessment
Appendix D Building Diagram with Locations of Asbestos-Containing Materials
Appendix E Asbestos Laboratory Report and Chain of Custody
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
1.0 Executive Summary
Landmark Environmental, LLC (Landmark) was retained by Anderson Engineering (Client) to conduct an asbestos survey (Survey) prior to a renovation project at the Veterans
Affairs (VA) Iowa City Health Care System located in Iowa City, Iowa (Property). The
Client intends to conduct a renovation project titled “Renovate Dialysis” (Project) on the
5th Floor of Building 1.
Landmark conducted a full asbestos survey of 5th floor south (5S), along with a limited survey of 5th floor west (5W) that will temporarily house the dialysis department during the construction Project. Stairwells and elevators were not included in the Survey.
An asbestos survey was previously conducted of Building 1 by Shive-Hattery, Inc. (Shive-
Hattery) in June 2016. No asbestos was found in the Project area during the Shive-
Hattery survey. Sample data from the Shive-Hattery survey was not used during the
Landmark Survey.
A summary of the Survey results are as follows:
Landmark collected 84 bulk asbestos samples as part of the Survey. The contracted laboratory, EMSL Analytical, Inc. (EMSL) separated these 84 samples into 95 individual sample layers and all 95 sample layers were analyzed.
Based on the laboratory report, suspect building materials found to contain asbestos include – gray adhesive on plaster, and 12” x 12” floor tile.
Building materials assumed to contain asbestos include – fire doors, and electric panels.
No attempt was made to locate materials inside walls, doors, ducts, and other areas that would require destructive entry. The possibility exists that materials may be present at these locations. Any untested building materials observed, or suspected in these areas, are assumed to be asbestos-containing. The possibility exists that as these locations are opened during renovation, suspect asbestos-containing material(s) (ACM) may be found.
Fire doors were not sampled since doing so would damage the integrity of the door and void the warranty of the product.
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
Electrical wiring and panels were not sampled for asbestos. Landmark does not perform bulk sampling of electrical equipment unless it has been shut down and tagged by a licensed electrician.
This Survey identifies ACM as they existed on the day of the Survey at the Property.
Conditions may change over time.
The ACM quantities provided are estimates and must be verified by the bidding contractors.
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
2.0 Introduction
Landmark completed an asbestos survey and associated report (Report) at the Property.
The procedures used for this Survey and assessment comply with the Environmental
Protection Agency (EPA), Occupational Safety and Health Administration (OSHA), Iowa
Division of Labor (IDL), and Iowa Department of Natural Resources (IDNR) asbestos standards.
2.1 Purpose
Landmark was retained by the Client to complete the Survey and provide a Report to identify ACM and to quantify ACM in the 5th floor work areas of the Property prior to commencing with a scheduled Project.
2.2 Survey Approach
The Survey, consisting of identifying, sampling, assessing, and quantifying suspect ACM within the Project area, was conducted on November 19, 2024. In 5S, a full survey was conducted on all materials in this portion of the Project area. In 5W, a limited survey was conducted. Only surfaces (flooring, walls, ceiling tiles, etc.) that may be impacted during the Project were included in the Survey. The 5W portion of the Project only involves moving furniture, and possibly tying into existing plumbing in the exam room restrooms as part of the dialysis equipment installation.
2.3 Assumptions, Limitations and Exceptions
The findings and recommendations in this Report are subject to the following assumptions, limitations, and/or exceptions:
• A limited asbestos survey was conducted in 5 West based on the proposed plans for the Project at the time of the Survey. Only flooring, walls, and ceiling materials that may be impacted during the Project were included in the Survey.
• No attempt was made to locate materials inside walls, doors, ducts, and other areas that would require destructive entry. The possibility exists that materials may be present at these locations. Materials observed, or suspected in these areas, are assumed to be ACM. The possibility exists that as these locations are opened during renovation, suspect asbestos-containing material(s) may be found.
• Electrical wiring and panels were not sampled for asbestos. Landmark does not perform bulk sampling of electrical equipment unless it has been shut down and tagged by a licensed electrician.
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
• Fire doors were not sampled since doing so would damage the integrity of the door and void the warranty of the door. Fire doors must be treated as asbestos-containing during abatement, or sampled to determine if they contain asbestos prior to disturbance.
• This Survey identifies materials as they existed on the day of the Survey. Conditions may change over time.
2.4 Qualifications
The Survey was conducted by Mark Meier, an accredited asbestos building inspector with Landmark. A photocopy of the inspector’s IDL certification is included in Appendix A.
Asbestos sample analysis for this project was conducted by EMSL located in New Hope, Minnesota. EMSL is accredited by the National Voluntary Accreditation Program for bulk asbestos analysis (NVLAP lab code 200019-0).
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
3.0 Sampling Methods and Analysis
3.1 Bulk Asbestos Sampling
Building diagrams were utilized to divide the Property building into functional spaces for the purpose of describing sampling locations. The building diagram with sample locations has been included in Appendix B.
Similar systems and materials were grouped into “homogeneous areas of building materials” (homogeneous materials). Homogeneous materials often exist in more than one functional space within the Property building. Each homogeneous material was assigned a discrete number; the homogeneous material number is indicated in the first number of the sample name. Multiple samples of each homogeneous material were taken in accordance with the EPA-Asbestos Hazard Emergency Response Act (AHERA) guidelines using a random sampling procedure. These multiple samples were designated “A, B, C,” etc. for each homogenous material, as indicated in the sample name. The sample locations and sample descriptions are shown on the building diagram (Appendix B) and the asbestos laboratory report (Appendix E).
Samples were collected by wetting and carefully removing a small representative sample of the suspect material and sealing it in a plastic bag.
3.2 Bulk Asbestos Analysis
Landmark collected 84 bulk asbestos samples as part of the Survey. EMSL separated these 84 samples into 95 individual layer samples and all 95 individual layer samples were analyzed.
The bulk samples were analyzed by polarized light microscopy (PLM) with dispersion staining, EPA method 600/R-93/116 and EPA method 600/M4-82-020. Quantity determinations are made by visual estimation. For each homogeneous material, once a positive sample was identified, the remaining samples were not analyzed.
EPA National Emission Standards for Hazardous Air Pollutants (NESHAP)-Rule 40 CFR
Part 61 states that samples found to contain less than 10% asbestos by visual estimation may be further quantified by point count analysis.
The EPA Asbestos rule states all multi-layer systems, except for wall systems where joint compound was used only at the joints and nail holes, must be analyzed as separate materials. If any layer contains greater than one percent asbestos, that layer must be treated as asbestos-containing. This requires all layers in a multi-layered system to be
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx treated as asbestos-containing if the layers cannot be separated without disturbing the asbestos-containing layer.
Asbestos samples will be held for 30 days after the date of this report.
3.3 Chain of Custody Procedures
To ensure that samples collected in the field are neither lost nor their identity mis-identified, all samples, from the point of collection to receipt in the laboratory, proceeds as follows. Each sample is first assigned a unique and distinct sampling number. After a sample is placed into a plastic bag, that unique number is assigned to that bag. This same number is documented on the laboratory’s chain of custody. The inspector signs each chain of custody before delivering to the lab. Upon receipt of the samples, the lab analyst verifies that each sample matches the corresponding chain of custody number and signs and dates the chain of custody. After analysis, the analyst generates a report that includes the sample results and the project chain of custody forms.
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
4.0 Asbestos-Containing Material Assessment
In each functional space, each homogeneous material was quantified and assessed for friability (i.e. material can be crumbled, pulverized, or reduced to powder by hand pressure when dry). Suspect ACM was then assessed as to their condition and potential for disturbance. This information was recorded on the asbestos physical assessment shown in Appendix C. The model for this system is described in the EPA Draft
Curriculum for Training Building Inspectors.
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
5.0 Findings
5.1 Summary of Asbestos-Containing Materials
Suspect homogeneous materials found to contain asbestos, and their sample numbers, include:
Thermal Insulation
No ACM Observed
Surfacing Material
No ACM Observed
Miscellaneous Materials
Gray adhesive on plaster (Sample 6A).
12” x 12” floor tile, white with gray (Sample 102).
Assumed Materials Fire doors
Electric panels
5.2 Summary of Non-Asbestos-Containing Materials
Suspect ACM is considered negative for asbestos when all samples of the material are found to contain one percent or less asbestos. Suspect homogeneous materials observed, sampled, and found to be negative during Landmark’s Survey includes:
1. Sheetrock and joint compound (Sample 1).
2. Plaster (Sample 2).
3. Black adhesive on concrete wall (Sample 3).
4. 2’ x 2’ ceiling tile, white texture reveal with small fissures and holes (Sample 4).
5. 2’ x 2’ ceiling tile white reveal (Sample 5).
6. Tan adhesive behind sheetrock (Sample 7).
7. Floor sheeting, cream with blue specks & adhesive (Samples 8 & 22).
8. Tan baseboard & adhesive (Samples 9 & 10).
9. 12” x 12” floor tile, pinkish cream with smears & mastic (Samples 11 & 12).
10. Dark gray baseboard & adhesive (Samples 13 & 14).
11. Vinyl flooring, orangish wood plank (Sample 15).
12. Floor sheeting, light blue with white specks & adhesive (Samples 16 & 17).
13. Window caulk, white (Sample 18).
14. Window glazing, interior window (Sample 19).
15. Brown firestop putty (Sample 20).
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
16. Gray duct sealant (Sample 21).
17. Floor sheeting, blue gray with gray specks & adhesive (Samples 23 & 24).
18. Floor sheeting, tan with cream specks (Sample 25).
19. Black baseboard & adhesive (Samples 26 & 27).
20. Gray splashguard adhesive (Sample 28).
21. Dark brown baseboard & adhesive (Samples 29 & 30).
22. Carpet glue, green and tan (Sample 31).
23. White firestop putty (Sample 32).
24. Gray sink undercoating (Sample 33).
25. Brown gummy firestop putty (Sample 34).
26. 2” tan ceramic floor tile, mortar, & grout (Samples 35, 36, & 37).
27. 2” white ceramic wall tile, mortar, & grout (Samples 38, 39 & 40).
28. Plaster (Sample 100).
29. Sheetrock and joint compound (Sample 101).
30. Floor tile mastic, black (Sample 103).
31. 12” tan ceramic wall tile, mortar & grout (Samples 104, 105, & 106).
32. 2” brown ceramic floor tile, mortar, & grout (Samples 107, 108, & 109).
33. 2’ x 2’ ceiling tile, white revel (Sample 110).
34. 12” x 12” floor tile, cream with tan & mastic (Samples 111, & 112).
35. Floor sheeting, gray plank (Sample 113).
36. Black baseboard & adhesive (Samples 114, & 115).
37. Floor sheeting, red stained with wood grain (Sample 116).
5.3 Summary of ACM & Quantities
This Survey was conducted to locate and quantify ACM in the Project area of the
Property building. Based on the Survey and laboratory results, each identified ACM and the estimated quantity of each are summarized below.
Description Total Estimated
Thermal System Insulation
No ACM observed
Surfacing Material No ACM observed
Miscellaneous Materials
Gray adhesive on plaster 10 sf
12” x 12” floor tile, white with gray 100 sf
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
Assumed Materials
Fire doors 7 doors
Electric panels 5 panels
5.4 Recommendations
This Survey was conducted to locate and quantify ACM in the Project area of the
Property building. Based on the Survey and laboratory results, as well as the construction plans provided, the recommendations for the identified ACM are included below.
Remove the ACM identified in this report in accordance with the specifications accompanying this report.
If untested material(s) are discovered during renovation or demolition activities, work shall stop immediately. Assume the material(s) contains asbestos or have the material(s) tested to determine asbestos content.
Provide this report to contractor(s) who are working in or around the location(s) where the renovation or demolition activities are occurring, so they are aware of the materials containing asbestos and their locations. In addition, the contractor(s) should be aware of what materials have not been sampled for asbestos and what they should do upon encountering untested materials or suspect ACM.
If this report is reproduced, this report must be copied in its entirety.
F:\PROJECTS\AND-Anderson Engineering\Iowa City - Dialysis Project\Asbestos Survey\Iowa City VAMC Building 1 Level 5-
Renovate Dialysis Asbestos Draft Report 12232024.docx
6.0 Signatures of Environmental Professional(s)
We declare that, to the best of our professional knowledge and belief, the Survey referenced by this report, and the report itself, were conducted in accordance with intent of the EPA, IDNR, IDL, and AHERA regulations to the best of my ability and knowledge.
Mark Meier
Asbestos Building Inspector (24-12078)
Eric Gabrielson, Vice President
Appendices
Appendix A
Appendix B
10 11
0 4' 8' 16'
168 SF
5S25
STAFF
LOUNGE
152 SF
5ST05
Room 33 SF
5S22
STAFF TLT
33 SF
5S520
HSKPG
152 SF
5CS02A
CORRIDOR
36 SF
5S26
CHANGE
ROOM
20 SF
5S23
LINEN
121 SF
5S14
DIALYSATE
STORAGE
146 SF
5S14A
MIT
WORKROOM
106 SF
5S18
REPROCESS
STORAGE
43 SF
5S19
PATIENT
TLT
219 SF
5S21
DIALYSIS
81 SF
5S11
CHIEF
OFFICE
56 SF
5S09
MED PREP
155 SF
5S05
ISOLATION
ROOM
41 SF
5S05A
ISO TLT
70 SF
5S03
SOILED
UTILITY
129 SF
5S01
OFFICE
134 SF
5S04
RECEPTION
5W101
5C01
5W100
5W03
5W05
5W07
5W09A
29 SF
5S04A
STAFF TLT
5E025E04A5E04
172 SF
5S24
RO WATER
TREATMENT
5S28
DIALYSIS
CUBICLES
5S29
DIALYSIS
CUBICLES
5CS02
CORRIDOR
5S27
NURSE
STATION
KEYPLAN - ZONE 1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CHARETTE REPORT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
IMEG CORP
2882 106th St Des Moines, IA 50322
Contact: Dellan Llewellyn
(515) 334-7921
C U s e rs \M
C a m e ro n \D o c u m e n ts \1
-I C
V A
F L
R -A
-R m c a m e ro n M
T
.r v t
/2
/2
:0
:4
P
M
AD111
FIFTH LEVEL DEMOLITION PLAN -
ZONE 1
RENOVATE DIALYSIS
Iowa City, IA
636A8-24-001 xx/xx/xxxx X X 17909
3/16" = 1'-0"
FIFTH LEVEL DEMOLITION PLAN - ZONE 1
Revisions: Date:
Asbestos Sample Diagram
Non-asbestos containing sample location
Asbestos containing sample location00
35A 38A 36A 39A 37A 40A
6A 1A 5A 2A 7A 3A 8A 4A 22A 9A
10A 11A 12A 2B
13A 14A 15A1B
16A 17A 18A
2C
5W01
100A
8B 19A 22B
20A 21A
23A 24A 25A 26A 27A 28A
4B 5B 29A 30A 31A
32A
11B 12B
21B
23B 24B
1C
2D 2E 3B 20B
2F 2G 18B 34A 33A
5W100
5W07
5W09A
5W09
5W06
5W06A
5W08
5W10
123 SF
5W12
CLEAN
UTILITY
87 SF
5W14
SOILED
UTILITY
25 SF
5W16
TOILET
148 SF
5W18
SOILED
PROCESSING
5W17
5W17A
5C W03A
CORRIDOR
169 SF
5W19
CLEAN / MIT
WORKROOM
135 SF
5W20
ISO BED
DIALYSIS
STATION
59 SF
5W20A
TOILET
62 SF
5W18A
TOILET
5W30A
5ST04
5W24
161 SF
5W30
DIALYSIS
STATION
164 SF
5W32
DIALYSIS
STATIONS
5W32A 5W34A
175 SF
5W34
DIALYSIS
STATIONS
5ST13
5W35
201 SF
5W33
STORAGE
5W33A5W31A
193 SF
5W31
DIALYSIS
STATIONS
235 SF
5W29
DIALYSIS
STATIONS
5C W05
85 SF
5W21
MED PREP
50 SF
5W22
NUTRITION
37 SF
5W25
HSKPG
46 SF
5W15B
TOILET
74 SF
5W29A
TOILET
48 SF
5W27
TOILET
381 SF
5W15
PROVIDER
WORKSTATIONS
5C W03B
193 SF
5W13
BREAKROOM
5W11
REF
ICE
T
R
N
5W11A
5W08A
261 SF
5S24
CHARTING &
RECEPTION
5C W02
CORRIDOR
5C W01
CORRIDOR
70 SF
5W19A
TOILET
16 17 19.1 20.1 21.1
22 23 24
J
K
L
M
5W12
5W11A
5W11 5W13
5W15B5W15
5W25 5W27 5W29
5W29A
5C W05
5W17
5W17A
5W19C 5W19A
5W19
5W18A
5W18
5W16
5W14
5C W03A
5W21
5W22
5C W02
5W20
5W31
5W34
5W33
5W325W30
5W30A 5W32A 5W34A
5W33A 5W31A
5W20A
2119 20
FL2
FL2
FL2
FL2
FL2
20'-6" 21'-5" 8'-8" 16'-1" 25'-10" 20'-6" 21'-0"
134'-0"
66'-8" 67'-4"
13'-9" 8'-8" 13'-9"
KEYPLAN - ZONE 2
TRUE
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
SCHEMATIC DESIGN
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
35% SD SUBMISSION
NOT FOR CONSTRUCTION
IMEG CORP
2882 106th St Des Moines, IA 50322
Contact: Dellan Llewellyn
(515) 334-7921
C U s e rs \M
C a m e ro n \D o c u m e n ts \1
-I C
V A
F L
R -A
-R m c a m e ro n M
T
.r v t
/1 /2
:4
:3
A
M
1-A5
5TH FLOOR - FLOOR PLAN - ZONE
RENOVATE DIALYSIS
IOWA CITY, IA
636A8-24-001
11/12/2024 EM MWC
17909
3/16" = 1'-0"1 FIFTH FLOOR WEST PLAN - TEMP SPACE
Revisions: Date:
0 5'4" 10'8"2'8"
Asbestos Sample Diagram
Non-asbestos containing sample location
Asbestos containing sample location00
101A 110A 113B
116B
104 107 105 108 106 109
113A
101B 110B
114A 115A
101C
114B 115B116A
Appendix C
12/18/2024 BUILDING 1 RENOVATE DIALYSIS - IOWA CITY VAHCS
IOWA CITY, IOWA
ASBESTOS-CONTAINING MATERIAL ASSESSMENT DATABASE
Floor Location Type Description Quantity
Height
(Feet) Condition
Disturbance
Potential
Homog.
Material
5 5S24 (RO Mechanical Room) MISC Electric Panel 3 panels 5 G L Assumed
5 5S24 (RO Mechanical Room) MISC Fire Door (1.5 hour) 1 door 0-7 G L Assumed
5 5S24 (RO Mechanical Room) MISC Gray adhesive on plaster (above drop ceiling) 10 sf 9 G L 6
5 5S22 (Staff Restroom) No ACM Observed
5 5S20 (Janitors Closet) No ACM Observed
5 5S26 (Locker Room) No ACM Observed
5 5525 (Break Room) No ACM Observed
5 5S23 (Linen Room) No ACM Observed
5 5S21 No ACM Observed
5 5S19 (Patient Restroom) No ACM Observed
5 5S11 No ACM Observed
5 5S05 No ACM Observed
5 5S03 MISC Fire Door (1 hour) 1 door 0-7 G L Assumed
5 5S01 No ACM Observed
5 5S04 No ACM Observed
5 5S14 MISC Fire Door (1 hour) 1 door 0-7 G L Assumed
Type: TSI=Thermal System Insulation SURF=Surfacing Materials MISC=Misc.
Quantity: CF=Cubic Ft LF=Linear Ft SF=Square Ft Condition: G=Good F=Fair P=Poor Dist. Pot.: L=Low M=Medium H=High
ASBESTOS-CONTAINING MATERIAL ASSESSMENT DATABASE
Floor Location Type Description Quantity
Height
(Feet) Condition
Disturbance
Potential
Homog.
Material
5 5S14A No ACM Observed
5 5S18 MISC Fire Door (1 hour) 1 door 0-7 G L Assumed
5 5S09 No ACM Observed
5 Corridor/Common Area MISC Fire Doors (20 min) 2 door 0-7 G L Assumed
5 5W11 & 5W11A No ACM Observed
5 5W13 & 5W13A No ACM Observed
5 5W13B No ACM Observed
5 5W15 & 5W15B No ACM Observed
5 5W21 No ACM Observed
5 5W22 No ACM Observed
5 5W25 No ACM Observed
5 5W27 No ACM Observed
5 5W29 & 5W29A No ACM Observed
5 5W31 & 5W31A No ACM Observed
5 5W33 & 5W33A No ACM Observed
Quantity: CF=Cubic Ft LF=Linear Ft SF=Square Ft Condition: G=Good F=Fair P=Poor Dist. Pot.: L=Low M=Medium H=High
ASBESTOS-CONTAINING MATERIAL ASSESSMENT DATABASE
Floor Location Type Description Quantity
Height
(Feet) Condition
Disturbance
Potential
Homog.
Material
5 5W35 MISC Fire Door 1 door 0-7 G L Assumed
5 5W34 & 5W34A No ACM Observed
5 5W32 & 5W32A No ACM Observed
5 5W30 & 5W30A No ACM Observed
5 5W24 No ACM Observed
5 5W17 & 5W17A No ACM Observed
5 5W19 & 5W19A No ACM Observed
5 5W20 & 5W20A No ACM Observed
5 5W18 & 5W18A No ACM Observed
5 5W16 No ACM Observed
5 5W14 No ACM Observed
5 5W12B No ACM Observed
5 5W08 & 5W08A No ACM Observed
5 5W01 MISC 12" x 12" floor tile, white with dark gray streaks 100 sf 1 G L 102
5 5W01 MISC Electric panels 2 panels 5 G L Assumed
Quantity: CF=Cubic Ft LF=Linear Ft SF=Square Ft Condition: G=Good F=Fair P=Poor Dist. Pot.: L=Low M=Medium H=High
ASBESTOS-CONTAINING MATERIAL ASSESSMENT DATABASE
Floor Location Type Description Quantity
Height
(Feet) Condition
Disturbance
Potential
Homog.
Material
5 5W25 No ACM Observed
5 5W10 No ACM Observed
5 West Corridor No ACM Observed
Quantity: CF=Cubic Ft LF=Linear Ft SF=Square Ft Condition: G=Good F=Fair P=Poor Dist. Pot.: L=Low M=Medium H=High
Appendix D
Appendix E
EMSL Analytical, Inc.
3410 Winnetka Avenue North New Hope, MN 55427
Tel/Fax: (763) 449-4922 / (763) 449-4924 http://www.EMSL.com / minneapolislab@emsl.com
352411034EMSL Order:
Customer ID: LMEN42
Customer PO:
Project ID:
Attention: Phone:Mark Meier (952) 666-2422
Fax:Landmark Environmental, LLC (952) 887-9605
Received Date:9555 James Avenue South – Suite 262 11/20/2024 3:55 PM
Analysis Date:Bloomington, MN 55431 11/26/2024 - 11/27/2024
Collected Date:
Project: VAMC Iowa City/23107.02
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1A
352411034-0001
None DetectedNon-fibrous (Other)96%Glass4%White
Non-Fibrous
Heterogeneous
Sheetrock + Joint
Compound
This is a composite result of wallboard, jt. compound, and tape
1B
352411034-0002
None DetectedNon-fibrous (Other)97%Glass3%White
Non-Fibrous
Heterogeneous
Sheetrock + Joint
Compound
This is a composite result of wallboard, jt. compound, and tape
1C
352411034-0003
None DetectedNon-fibrous (Other)94%Cellulose
Glass
3%
3%
White
Non-Fibrous
Heterogeneous
Sheetrock + Joint
Compound
This is a composite result of wallboard, jt. compound, and tape
2A-Plaster
352411034-0004
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
2A-Skim Coat
352411034-0004A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
2B-Plaster
352411034-0005
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
2B-Skim Coat
352411034-0005A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
2B-Adhesive
352411034-0005B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Plaster
2C-Plaster
352411034-0006
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
2C-Skim Coat
352411034-0006A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
2D-Plaster
352411034-0007
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
2D-Skim Coat
352411034-0007A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
2E-Plaster
352411034-0008
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
2E-Skim Coat
352411034-0008A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
2F-Plaster
352411034-0009
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
Initial report from: 11/27/2024 14:34:35
Page 1 of 6ASB_PLM_0008_0002 - 2.31 Printed: 11/27/2024 2:34 PM
Tel/Fax: (763) 449-4922 / (763) 449-4924 http://www.EMSL.com / minneapolislab@emsl.com
352411034EMSL Order:
Customer ID: LMEN42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
2F-Skim Coat
352411034-0009A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
2G-Plaster
352411034-0010
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
2G-Skim Coat
352411034-0010A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
3A
352411034-0011
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black Adhesive
3B
352411034-0012
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black Adhesive
4A
352411034-0013
None DetectedPerlite
Non-fibrous (Other)
30%
5%
Cellulose
Glass
50%
15%
Beige
Fibrous
Homogeneous
2x2 CT White text
Reveal w/small F+H
4B
352411034-0014
None DetectedPerlite
Non-fibrous (Other)
30%
5%
Cellulose
Glass
50%
15%
Beige
Fibrous
Homogeneous
2x2 CT White text
Reveal w/small F+H
5A
352411034-0015
None DetectedPerlite
Non-fibrous (Other)
15%
10%
Cellulose
Glass
30%
45%
Beige
Fibrous
Homogeneous
2x2 CT white Reveal
5B
352411034-0016
None DetectedPerlite
Non-fibrous (Other)
15%
10%
Cellulose
Glass
15%
60%
Beige
Fibrous
Homogeneous
2x2 CT white Reveal
6A
352411034-0017
7% ChrysotileNon-fibrous (Other)93%Gray
Non-Fibrous
Homogeneous
Gray Adh on Plaster
7A
352411034-0018
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Tan Adh Behind
Sheetrock
8A
352411034-0019
None DetectedNon-fibrous (Other)35%Cellulose
Synthetic
40%
25%
Tan/Blue
Non-Fibrous
Homogeneous
Cream Floor Sheeting w/ blue Specs
8B
352411034-0020
None DetectedNon-fibrous (Other)35%Cellulose
Synthetic
40%
25%
Tan/Blue
Non-Fibrous
Homogeneous
Cream Floor Sheeting w/ blue Specs
9A
352411034-0021
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Tan BB
10A
352411034-0022
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BB Adh
11A
352411034-0023
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
12"x12" FT pinkish cream w/ smears
12A
352411034-0024
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
FT Mastic
11B
352411034-0025
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
FT Mastic
12B
352411034-0026
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
FT Mastic
Page 2 of 6ASB_PLM_0008_0002 - 2.31 Printed: 11/27/2024 2:34 PM
Tel/Fax: (763) 449-4922 / (763) 449-4924 http://www.EMSL.com / minneapolislab@emsl.com
352411034EMSL Order:
Customer ID: LMEN42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
13A
352411034-0027
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Dark gray BB
14A
352411034-0028
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BB Adh
15A
352411034-0029
None DetectedNon-fibrous (Other)95%Glass5%White
Non-Fibrous
Homogeneous orangey wood plank flooring
16A
352411034-0030
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Floor sheet, Light
Blue w/ white specks
17A-Adhesive
352411034-0031
None DetectedNon-fibrous (Other)100%Green
Non-Fibrous
Homogeneous
Adhesive
17A-Leveler
352411034-0031A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Adhesive
18A
352411034-0032
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Window Caulk white
18B
352411034-0033
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Window Caulk white
19A
352411034-0034
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Window glazing on interior window
20A
352411034-0035
None DetectedNon-fibrous (Other)92%Synthetic8%Red
Non-Fibrous
Homogeneous
Brown firestop putty
20B
352411034-0036
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
Brown firestop putty
21A
352411034-0037
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous gray duct sealant
21B
352411034-0038
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous gray duct sealant
22A
352411034-0039
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Adhesive under #8
22B
352411034-0040
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Adhesive under #8
23A
352411034-0041
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Blue/Gray floor sheeting w/ gray specs
23B
352411034-0042
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Blue/Gray floor sheeting w/ gray specs
24A
352411034-0043
None DetectedNon-fibrous (Other)90%Cellulose10%Gray/Green
Non-Fibrous
Homogeneous
Adhesive under 23
24B
352411034-0044
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Adhesive under 23
Page 3 of 6ASB_PLM_0008_0002 - 2.31 Printed: 11/27/2024 2:34 PM
Tel/Fax: (763) 449-4922 / (763) 449-4924 http://www.EMSL.com / minneapolislab@emsl.com
352411034EMSL Order:
Customer ID: LMEN42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
25A
352411034-0045
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Tan w/ cream specs floor sheeting
26A
352411034-0046
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black BB
27A
352411034-0047
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BB adh
28A
352411034-0048
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous
Gray Splashguard
Adh
29A
352411034-0049
None DetectedNon-fibrous (Other)100%Gray/Black
Non-Fibrous
Homogeneous
Dark brown BB
30A
352411034-0050
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BB Adh
31A
352411034-0051
None DetectedNon-fibrous (Other)100%Yellow/Green
Non-Fibrous
Homogeneous green + Tan Carpet
Glue
32A
352411034-0052
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
White FS putty
33A
352411034-0053
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous gray Sink SD
34A
352411034-0054
None DetectedNon-fibrous (Other)90%Synthetic10%Red
Non-Fibrous
Homogeneous
Brown gummy Fire
Stop putty
35A
352411034-0055
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
2" Tan ceramic FT
36A
352411034-0056
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
2" Tan ceramic Mortar
37A
352411034-0057
None DetectedNon-fibrous (Other)96%Cellulose4%Gray
Non-Fibrous
Homogeneous
2" Tan ceramic Grout
38A
352411034-0058
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
2" White Ceramic WT
39A-Mortar
352411034-0059
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
2" White Ceramic WT
Mortar
39A-Adhesive
352411034-0059A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
2" White Ceramic WT
Mortar
40A
352411034-0060
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
2" White Ceramic WT
Grout
100A-Plaster
352411034-0061
None DetectedNon-fibrous (Other)100%White/Various
Non-Fibrous
Homogeneous
Plaster
100A-Skim Coat
352411034-0061A
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Plaster
Page 4 of 6ASB_PLM_0008_0002 - 2.31 Printed: 11/27/2024 2:34 PM
Tel/Fax: (763) 449-4922 / (763) 449-4924 http://www.EMSL.com / minneapolislab@emsl.com
352411034EMSL Order:
Customer ID: LMEN42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
101A
352411034-0062
None DetectedNon-fibrous (Other)95%Cellulose
Glass
2%
3%
White
Non-Fibrous
Heterogeneous
Sheet Rock + Joint
Compound
This is a composite result of wallboard, jt. compound, and tape
101B
352411034-0063
None DetectedNon-fibrous (Other)95%Cellulose
Glass
2%
3%
White
Non-Fibrous
Heterogeneous
Sheet Rock + Joint
Compound
This is a composite result of wallboard, jt. compound, and tape
101C
352411034-0064
None DetectedNon-fibrous (Other)94%Cellulose
Glass
3%
3%
White
Non-Fibrous
Heterogeneous
Sheet Rock + Joint
Compound
This is a composite result of wallboard, jt. compound, and tape
352411034-0065
7% ChrysotileNon-fibrous (Other)93%Tan
Non-Fibrous
Homogeneous
12x12 FT White w/
Gray
352411034-0066
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
FT Mastic
352411034-0067
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Ceramic Wall Tile 12"
Tan
352411034-0068
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Ceramic Wall Tile
Mortar
352411034-0069
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Wall Tile
Grout
352411034-0070
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
2" Brown Ceramic
Floor tile
352411034-0071
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
2" Brown Ceramic
Floor Mortar
352411034-0072
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
2" Brown Ceramic
Floor Grout
110A
352411034-0073
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Glass
25%
45%
Beige
Fibrous
Homogeneous
2x2 CT white Reveal
110B
352411034-0074
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Glass
25%
45%
Beige
Fibrous
Homogeneous
2x2 CT white Reveal
352411034-0075
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
12x12 FT Cream w/
Tan
352411034-0076
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
FT Mastic
113A
352411034-0077
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Gray Vinyl Plank flooring
113B
352411034-0078
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Gray Vinyl Plank flooring
114A
352411034-0079
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black BB
Page 5 of 6ASB_PLM_0008_0002 - 2.31 Printed: 11/27/2024 2:34 PM
Tel/Fax: (763) 449-4922 / (763) 449-4924 http://www.EMSL.com / minneapolislab@emsl.com
352411034EMSL Order:
Customer ID: LMEN42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
114B
352411034-0080
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black BB
115A
352411034-0081
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BB Adh
115B
352411034-0082
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
BB Adh
116A
352411034-0083
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous red stained Flooring, wood grain
116B
352411034-0084
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous red stained Flooring, wood grain
Analyst(s)
Andrew Capaul (95) Rachel Travis, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. New Hope, MN NVLAP Lab Code 200019-0; Colorado AL-24478
Page 6 of 6ASB_PLM_0008_0002 - 2.31 Printed: 11/27/2024 2:34 PM
OrderID: 352411034
3345 Stop 8 Rd, Dayton OH 45414 • (800) 535-5585 • (937) 461-1988 fax • www.ameriwater.com
December 19, 2024
Iowa City VA Medical Center 601 US 6 West Iowa City, IA 52246
ATTN: Ed Markfort EMarkfort@ae-mn.com
Quote Number: 52016A – Dialysis Central System – Quote SAC Contract: #36C10G22D0010
Dear Mr. Markfort:
Hope you are well.
Enclosed you will find the AmeriWater proposal for the supply of a Central Dialysis Water Treatment System for the Iowa City VAMC.
CLIN’s quoted: #2001AA (QTY 1) and #2001AG (QTY 12)
AmeriWater is one of the few water treatment companies that offers a FDA 510K certification on all components. All components have been carefully selected and sized to meet your specific requirements.
If you have any questions please do not hesitate to contact me.
We truly appreciate this opportunity to be of service.
Sincerely, Travis Tashjian Vice President of Strategic Accounts AmeriWater mailto:EMarkfort@ae-mn.com
2022 Heat Central System Quote Template – Rev 7/14/22 Page 2 of 8
IOWA CITY VAMC
12 STATION WATER TREATMENT SYSTEM
#52016A 12.19.2024
This proposal encompasses the AmeriWater equipment of a direct feed system that meets both AAMI and FDA design standards for dialysis. The 510K authorization number issued for this AmeriWater, Inc. Class II Medical Device is K99159.
SCOPE:
This quotation covers the sale of equipment for a pure water system sized to provide 10 stations and 2 maintenance stations.
SIZING REQUIREMENTS:
- 3 Patient Shifts with a Total of 12 Hours of Operation
- 10 GPG Water Hardness with Softener Regeneration Every 2 Day(s)
- New Loop – 1” PEX at an Estimated Loop Length of 300 Feet
- RO goes up to 90% recovery - dependant upon water quality and usage
- High recovery mode to keep water under 90 gallons per treatment – dependant upon water quality and usage
- Minimum RO Recovery Rate of 75%
- Requires 0 Acid Tanks and 0 Bicarb Tanks
- Voltage Requirements of 208V, 3 PH
EQUIPMENT:
CLIN #2001AA $227,532.34
Central Dialysis Water Purification and Distribution System for Dialysis Center: 1-12 Stations
Quantity Product Description Blend Valve Assembly:
1 0054-0037 1¼" x 1¼", Flow Range 5 - 37 GPM, Left to Right The all brass thermostatically controlled blend valve mixes hot and cold water to adjust the RO feed water to approximately 77°F (25°C) ±5°F. The blend valve is sized to the feed flow rate, which is twice the product flow. It has an adjustment knob for temperature adjustment and internal check valves on both the hot and cold sides to prevent back flow from one side to the other. The blend valve assembly includes inlet and outlet valves with a cold water bypass for service. Included are a pressure gauge and thermometer on the outlet. FRP unistrut is utilized to mount the assembly to the wall.
Booster Pump: CME Variable Pressure
1 0080190 1½ HP, 208-230V, 1PH
The variable pressure booster pump provides flow rates up to 25 GPM @ 50 PSI. Single pump design includes: stainless steel pump, installation plumbing including 3 valve bypass, check valve, outlet pressure gauge, and pressure switch. The control panel requires a 230V, single-phase power source. The controller will transform the 230V single-phase power to the required three-phase power to operate the pump motor.
Pretreatment Headers:
1 009602 1” Multiple 4 Carbon Tank with Bypass 2 009591 1" Assembly with Bypass
Header assembly includes isolation and bypass valves, outlet PSI gauge, and sample port.
2022 Heat Central System Quote Template – Rev 7/14/22 Page 3 of 8
System Pre-Filter 1 0021015 1", IN/OUT for 20" x 4½" Cartridges
The system pre-filter protects the pretreatment equipment from particulate matter that may be present in the source water. The pre-filter is sized for the highest required flow rate in the system. The pre-filter housing is all polypropylene construction with inlet and outlet isolation valves and pressure gauges. The design utilizes dual open-end (DOE) cartridges of 1-5 micron nominal filtration (greater than 80% efficiency). A sump drain and wrench are provided.
System Pre-Filter Cartridges:
2 20-1056 20" x 4½", 5 Micron, Polybond
Carbon Fleck 2850 SXT Backwashable Filters: Requires 29.71 Cubic Feet to Meet 10 Minute EBCT 4 0095031 24" x 65", 9 cu ft
All non-corrosive design with acid-washed, granular activated carbon with Fleck Series 2850 control head, electronic 7-day timer with programmable backwash time at any time of day.
A full flow 1½” valve. Filter has 12 x 40 mesh with an iodine number greater than 1,000.
Filters interface to lockout the RO when in backwash. Pretreatment headers are sold separately.
Automatic Fleck 2850 SXT Water Softener: Based on 10 Grains Hardness (Subject to change based on actual water hardness)
1 0095016 24" x 65", 270,000 Grains A single tank water softener sized to the maximum possible water usage by the RO based on the water hardness and a 30% safety factor is designed to regenerate every night that the center operates. A full flow 1½” valve. The water softener is constructed of all non-corrosive components with a programmable electronic 7-day timer Fleck 2850 control, with the time of regeneration and all cycles fully adjustable. Pretreatment headers are sold separately.
RO Pre-Filter:
1 0021015 1", IN/OUT for 20" x 4½" Cartridges
The RO pre-filter protects the RO membranes from plugging with carbon fines. The pre-filter is sized for twice the rate of the RO product water. The pre-filter housing is all polypropylene construction with inlet and outlet isolation valves and pressure gauges. The design utilizes dual open-end (DOE) cartridges of 1-5 micron nominal filtration (greater than 80% efficiency). A sump drain and wrench are provided.
MRO Pre-Filter Cartridges:
2 20-1016 20" x 4½", 1 Micron, Polybond
RO Bypass Headers:
1 0011-0039 1” Loop, 1” Pretreatment
2022 Heat Central System Quote Template – Rev 7/14/22 Page 4 of 8
Reverse Osmosis System:
1 00MDP4-230 Dual Pass, 5 Membrane, up to 14,400 GPD, 208/230V, 3 Ph
The MediQA system uses proven reverse osmosis technology combined with heat disinfection to provide a unique combination of performance, reliability, and functionality.
This fully integrated water purification solution when coupled with pre-treatment and PEX distribution pipework makes a complete system. Dual Pass membrane configuration provides maximum flexibility in water quality. Automated heat disinfection of RO membranes provides system efficiency/labor savings and ensures that any potential for bacterial growth on membrane surfaces is minimized. Full color touch screen display with comprehensive menu navigation, including full schematics. Advanced data logging technology with password protection. Information is available via an integrated touch screen display or downloaded to Excel. Stored data includes active status indicators, alarm conditions and performance logs. 8” TFC membranes in FRP vessels. Compact, powder coated aluminum skid mounted package. Note: Permeate flow rate at 77°F. Variations in feed water temperature can affect output by up to ± 3% per degree Fahrenheit. Based on 1,000 microsiemens water or less.
Heat Disinfection System:
1 00HS20815 460V, 15 kW, 3 Ph
The HeatSan is an integrated heat disinfection system for disinfecting the distribution loop and dialysis machines with the ability to adjust for each day of the week, heating intervals, holding times and disinfection temperatures. Provides up to 100 gallons of 185°F hot water and can disinfect two separate loops. The PLC controller, dual color touch screen displays alarms, system status, tank level, disinfection temperatures and event log with added password protection. Easy step through programming (7 day program) syncs dialysis machines with the HeatSan. Intelligent monitoring routines, leak detection, and over use.
The heat disinfect will abort if leak is detected. There are four levels of password protection.
The event log holds up to 12 months of data and can be downloaded to Excel. Stainless steel skid complete with insulated stainless steel storage tank with sloping base fitted with three phase heating elements, level transmitter and temperature monitor. Stainless steel recirculation pump, stainless steel solenoid valves. The isolation of the RO and bicarb mixing system is accomplished with three way motorized ball valves that are controlled by the HeatSan.
Installation Kit:
1 0088-0008 Heatsan to MediQA, 1”
Post-Treatment Rack:
1 00PTR2-L2R 1” Dual Housing, 20”, Left to Right
An ultra-filter for endotoxin is required on systems utilizing a storage tank or deionizer tanks. Aluminum powder-coated frame has dimensions of 26 9/16” x 14 ¼” x 65 ⅜”and consists of a DI bypass header, alarm panel, and single or dual endotoxin housings.
Endotoxin equipped with pressure gauges, inlet/outlet sample ports, inlet/outlet manual isolatation valves, and drain valves. DI bypass includes 1 Meg-Ohm resistivity monitor, resistivity monitor probe, automatic dump valve, and sample port. Alarm Panel with both conductivity/resistivity monitors and ability to communicate with RO, bicarb, and Heatsan disinfection system.
2022 Heat Central System Quote Template – Rev 7/14/22 Page 5 of 8
Endotoxin Filter Cartridges:
4 20-3046 0.2 Micron, 2.5" x 20", 222, Pall, 10 GPM
CMS Water Treatment Label Kit:
1 99-9075 Label Kit
Includes color coded directional flow arrows and product identification labels to meet CMS requirements.
Central System Valve Tags and Labels:
1 0099-0001 Central System Valve Tags (100) and Labels
Pretreatment Water Sample Port Box:
1 0082-0024 Pretreatment Water Sample Port Box The AmeriWater sample box for pretreatment water is designed to deliver test sample water to a central collection point. This provides easy sampling and draining of the test lines. Single piece ABS construction wall box is recessed to prevent damage to the valves.
Water valves are PVC ball type with a lever handle for ease of operation. Measuring cup makes sure tubing to the sample box is flushed before sample is drawn. Drain connection is 1” PVC pipe.
Installation Kits:
1 0088-0020-3 Kit, Install, 1.0" Loop, PEXa, 0-400, With Insulation 1 001-142-0002 Central System Drain Waste Manifold 2" 1 001-014-0005 Complete Water System Install Kit, 1.0” Pretreatment Manifolds
PACKAGING:
Packaging: Central Systems 1 PKG7-13 7 to 13 Stations
CLIN #2001AG $872.80 each Dialysis Wall Station Box with Connections for Water, Drain, Machine
PEX Wall Boxes*:
12 000-082-0040 Water Only, 1” PEX
White single piece ABS construction with an opening cut out of 14⅝"W x 13⅝"H with a depth of 4¾”.
* Wall boxes do not include dialysis machine fittings!
OFF – CONTRACT ITEMS $16,654.00
Dealkalizer
Series 2850 SXT Fleck Chloride Anion Dealkalizer:
1 0095051 24" x 65", 9.5 cu ft, Flow Rate 27 GPM
A full flow 1½” valve. The dealkalizer is constructed of all non-corrosive components with a programmable electronic 7-day timer Fleck 2850 control, with the time of regeneration and all cycles fully adjustable. Pretreatment headers are sold separately. Grain capacity depends on water analysis. Max flow rate based on 3 GPM per cubic foot.
2022 Heat Central System Quote Template – Rev 7/14/22 Page 6 of 8
INSTALLATION:
Installation of complete water treatment system listed in this proposal with the following exceptions. The buyer is responsible for:
- Supplying hot and cold water supply
- Completion of site preparation requirements – To be determined
- Installation of all required drains
- Piping to drain for wall boxes
- Wall box installation to cabinetry
- Installation of hanging support requirements (for distribution loop)
- All electrical wiring and utilities including disconnects
The following are AmeriWater requirements to consider when providing your installation quote.
1. System requires hot and…