S02_BNJ_Door Cylinders_Reno Dialysis_IC_Redacted.pdf

PDF 254 KB Posted

Attached to
Z1DA--Renovate Dialysis PN: 636A8-24-001 Iowa City, IA
Solicitation number
36C26326B0005
Issued by

About this file

This document is a Brand Name Justification for Simplified Acquisition Procedures (SAP) for the Veterans Health Administration (VHA), specifically for the Iowa City VA Medical Center. The procurement involves CORMAX Best (Stanley Security) door hardware cylinders for a dialysis renovation project (Project #636A8-24-001). The justification emphasizes the need for standardization, highlighting that these specific brand-name cylinders are currently the only ones installed in the facility and are critical for maintaining the existing security key management system.

The document details unique technical requirements for the door cylinders, including specifications such as having at least seven pins, removable core type, interchangeability with existing lock systems, and compatibility with the facility's current master key. The contracting office conducted market research and determined no competing vendors offer fully compatible products. The total procurement will be competitively bid, with offerors responsible for obtaining pricing from suppliers. The justification is prepared under FAR 13.106-1 and supports the procurement of door hardware cylinders that will enhance facility security while reducing maintenance and repair costs.

View the file

Other files

File Type Posted
AS06_Amend 0004_ICVA-Dialysis_ADD1_SpecVol2.pdf PDF
AS06_Amend 0004_ICVA-Dialysis_ADD1_Sheets_fullset.pdf PDF
AS06_36C26326B0005_Amendment 0004.pdf PDF
AS06_Amend 0004_PreBid Site Visit Sign-In_Reno Dialysis.pdf PDF
AS06_Amend 0004__Pre-Bid Site Walk QAs_Reno Dialysis.pdf PDF
AS06_Amend 0004_ICVA-Dialysis_ADD1_SpecVol3.pdf PDF
AS06_Amend 0004_SOC Building 1 and Bldg 50 2023.pdf PDF
AS06_Amend 0004_ICVA-Dialysis_ADD1_Narrative.pdf PDF
AS06_DBA WD_IA20260068_2Jan26.pdf PDF
AS06_Amend 0004_SOW Rev 2_Reno Dialysis_IC.pdf PDF
AS06_Amend 4_Round 2 Questions_Reno Dialysis.pdf PDF
AS06_Amend 0004_ICVA-Dialysis_ADD1_SpecVol1.pdf PDF
AS06_36C26326B0005_Amendment 0003.pdf PDF
AS06_36C26326B0005_Amendment 0002.pdf PDF
AS06_Amendment_36C26326B0005 0001_Reno Dialysis_IC.pdf PDF
AS06_Contracting Officers Special Information and Instructions_Revised.docx DOCX document
S02_BNJ_Speakers_Reno Dialysis_IC_Redacted.pdf PDF
S02_BNJ_Patient Lifts_Reno Dialysis_IC_Redacted.pdf PDF
S02_BNJ_Fire Alarm Hardware_Reno Dialysis_IC_Redacted.pdf PDF
S02_CD_Spec Vol 3_Reno Dialysis.pdf PDF
S02_ICVA-Dialysis_CD_SpecVol2_20251210.pdf PDF
S02_DBA WD_IA20250068_12Dec25.pdf PDF
S02_SOW NARA Contract Language.pdf PDF
S02_ICVA-Dialysis_CD_SpecVol1_20251210.pdf PDF
S02_Final SOW_Reno Dialysis_IC.pdf PDF
S02_36C26326B0005_IFB_Reno Dialysis_IC.pdf PDF
S02_VAAR 852.219-75_VA Notice of Limitations on Subcontracting.pdf PDF
S02_BNJ_Signage_Reno Dialysis_IC_Redacted.pdf PDF
S02_BNJ_Nurse Call Sys_Reno Dialysis_IC_Redacted.pdf PDF
S02_BNJ_Elec Panel Boards_Reno Dialysis_IC_Redacted.pdf PDF
S02_BNJ_ACS_Reno Dialysis_IC_Redacted.pdf PDF
S02_SSJ_BAS_Reno Dialysis_IC_Redacted.pdf PDF
S02_CD Narrative_Reno Dialysis_IC.pdf PDF
S02_CD_Drawings_Reno Dialysis_IC.pdf PDF
S02_BNJ_Code Green Sys_Reno Dialysis_IC_Redacted.pdf PDF
S02_SOW TMS 20939.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAPG Part 813.106 Simplified Acquisition Procedures Brand Name Justification for SAP under the SAT

Revision: 01 Effective Date: 11/15/2024 Page 1 of 3 Acquisition ID# 36C263-26-AP-0384

DEPARTMENT OF VETERANS AFFAIRS

Justification for Brand Name Awards IAW FAR 13.106-1 For

Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)

Acquisition Plan Action ID: 36C263-26-AP-0384

1. Contracting Activity:

Veterans Health Administration (VHA), NCO 23 Contracting Office

Department of Veterans Affairs, VISN 23, VAMC Iowa City

Project #: 636A8-24-001 Const – Renovate Dialysis

2237 #: 636-26-2-8896-0001

2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:

This project has a need for the CORMAX Best (Stanley Security) brand line. This door hardware cylinder requirement covers all the doors requiring cylinders affected by the scope of the project. The use of a particular brand name for the items listed below to accommodate standardization of these items throughout the facility. The CORMAX Best (Stanley Security) brand line for security door key cylinders with the following requirements (not all inclusive):

• Locks and latches for doors 45 mm (1-3/4 inch) thick or over must have beveled fronts.

• Lock cylinders must have not less than seven pins.

• Cylinders for all locksets must be removable core type. Cylinder must be removable by special key or tool.

• Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand Master Key System.

• Disassembly of lever or lockset must not be required to remove core from lockset.

• All locksets or latches on double doors with fire label must have latch bolt with 19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label.

• Provide temporary keying device or construction core to allow opening and closing during construction and prior to the installation of final cores.

https://www.acquisition.gov/?q=/browse/far/13

Effective Date: 11/15/2024 Page 2 of 3 Acquisition ID# 36C263-26-AP-0384

• Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset.

The approximate value of the CORMAX Best (Stanley Security) is .

3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:

This is a brand name justification in support of FAR 11.105, Items Peculiar to One Manufacturer.

The specified brand-named CORMAX Best is the only door cylinder that is currently being installed at the Iowa City VA Health Care System (ICVAHCS). The intent is to install the same door hardware cylinders throughout the medical center to use in-stock (readily available at the facility) replacement parts/materials and equipment for repairs of these doors which will significantly reduce maintenance and repair costs to the Government and aid in protecting against security breaches. Standardization of the facilities door hardware is imperative to be compliant with facilities physical security system.

The facility already uses a BEST CORMAX key system. This brand-name requirement is based on the need for specific, proprietary interchangeable cores that fit into existing door hardware without extensive modifications. CORMAX is a patented key system that provides a high level of security and protection against unauthorized key duplication. Introducing another system would compromise the integrity of the facility's overall security and key management plan. New cylinders must be operated by the facility's current master key to allow the locksmith shop to respond quickly and efficiently to maintenance issues and key requests. Using a different system would require facility staff to manage multiple, incompatible security systems, leading to increased training costs, personnel demands, and potential repair delays

By standardizing the door cylinders at the ICVAHCS, it allows the Government to take advantage of cost savings on spare replacement parts, and maintenance. It also allows standardization of the security of the facility and its door hardware. Should another door cylinder be used it would create duplication of costs for the Government and increase the possibility of security breaches at the facility.

4. Description of market research conducted and results or statement why it was not conducted:

The market research for the equipment was conducted and prepared by the COR and shared with the CO for further review. The CO was in concurrence with information provided in the estimate that supported the brand name items. Approval of the items as brand name only is critical for the overall efficiency of the completed project and the entire Iowa City VAMC facility.

The specified brand-named COREMAX Best is the only door cylinder that is currently being installed at the ICVAHCS. At this time, there are no known competing vendors whose products are fully compatible with the existing system being used at the ICVAHCS.

Effective Date: 11/15/2024 Page 3 of 3 Acquisition ID# 36C263-26-AP-0384

There will be competition for the overall procurement. It will be the responsibility of the offerors to obtain pricing from the suppliers of the items and to submit a competitive proposal for the project. If a requirement arises in the future to replace all door cylinders at the facility, a competitive acquisition will be considered.

5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106- 1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

CALVIN L. COURTNEY Date Contracting Officer Network Contracting Office 23 https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466 https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466

2025-12-10T10:29:10-0700
CALVIN COURTNEY

File details come from the government source that posted it. Updated .