P12_Lead Based Paint Analysis - Bldg 1 - 01.11.2017.pdf
PDF 1 MB Posted
- Solicitation number
- QSE--36C10F24R50025
About this file
This document is an analytical report from Micro-Methods Laboratory, Inc. detailing the results of a limited lead-based paint (LBP) inspection performed on various exterior painted surfaces of Building 1 at the VA Medical Center in Gulfport, MS. The inspection was conducted on January 11, 2017 by a state-certified LBP inspector. The report identifies the presence of lead in 8 of the 10 paint chip samples collected, with lead concentrations ranging from 116 ppm to 89,800 ppm. The inspection was performed in accordance with Mississippi regulations for LBP activities, and the results indicate that LBP is present on multiple building components. This information is likely relevant to an upcoming renovation project at Building 1, as referenced in the related federal contract opportunity, which requires the contractor to complete selective demolition, exterior building envelope alterations, and interior renovations, including upgrades to building systems and limited structural work.
View the file
Other files
Show 40 more
Latest 50 of 64 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6500 Sunplex Drive
Ocean Springs, MS 39564
228.875.6420 Phone
228.875.6423 Fax
LELAP Certification # 01960
Mailing Address:
PO Box 1410
Ocean Springs, MS
39566-1410
Roy Anderson Corp.
RE: VAMC Gulfport, MS Bldg. 1
Gulfport, MS 39502
PO Box 2
Matt Pringle
Enclosed are Micro-Methods Laboratory, Inc. results of analyses performed on samples received
01/11/17 15:20. If you have any questions concerning this report, please feel free to contact the office.
Sincerely, January 16, 2017
Harry P. Howell
President
Work Order # : 1701206
Purchase Order #:
Micro-Methods Laboratory, Inc.
DISCLAIMER
The results only relate to the items or the sample and/or samples received by the laboratory. This report shall not be reproduced except in full, without the approval of the laboratory. All test methods performed meet the requirements of NELAC 2009 Standards. Any variances and/or deviations specific to this analytical report are referenced in the lab report using qualifiers and detailed explanations found in the case narrative.
Project:
Project Number:
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
Sample ID Laboratory ID Matrix Date/Time Sampled
ANALYTICAL REPORT FOR SAMPLES
Date/Time Received
Sampled by
01-North Side Ext. Brick 1701206-01 Paint 01/11/17 10:50 01/11/17 15:20Clifford W. Meins
02-West Side Ext. Brick 1701206-02 Paint 01/11/17 10:55 01/11/17 15:20Clifford W. Meins
03-South Side Ext. Brick 1701206-03 Paint 01/11/17 11:00 01/11/17 15:20Clifford W. Meins
04-Chapel South Side Ext. Brick 1701206-04 Paint 01/11/17 11:15 01/11/17 15:20Clifford W. Meins
05-North Side Ext. Decorative Railing 1701206-05 Paint 01/11/17 11:20 01/11/17 15:20Clifford W. Meins
06-North Side Ext. Doors & Trim 1701206-06 Paint 01/11/17 11:25 01/11/17 15:20Clifford W. Meins
07-North Side Ext. Columns 1701206-07 Paint 01/11/17 11:35 01/11/17 15:20Clifford W. Meins
08-South Side Columns (Sampled Inside) 1701206-08 Paint 01/11/17 11:50 01/11/17 15:20Clifford W. Meins
09-South Side Ext. 1701206-09 Paint 01/11/17 11:55 01/11/17 15:20Clifford W. Meins
10-Chapel Ext. Fascia Board Trim 1701206-10 Paint 01/11/17 12:05 01/11/17 15:20Clifford W. Meins
Sample Receipt Conditions
1/11/2017 3:20:00PM
Sarah E. Tomek
1/11/2017 3:42:00PM Sarah E. Tomek
Lab Pick-upShipped by:Date/Time Received:
Received by:
Date/Time Logged: Logged by:
Clifford W. MeinsSubmitted by:
no cooler
Custody Seals
Containers Intact
COC/Labels Agree
Labels Complete
COC Complete
Received on Ice
No Ice, Short Trip
Obvious Contamination
Rush to meet HT
No
Yes
Yes
No
Yes
No
No
No
No
Receipt Temperature:Cooler ID: °C
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 2 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
CASE NARRATIVE SUMMARY
All reported results are within Micro-Methods Laboratory, Inc.defined laboratory quality control objectives unless detailed in narrative summary or identified as qualifications. NOTE: All results listed on this report are calculated on a wet weight basis (as received by the laboratory) unless otherwise noted in the analysis qualification sections.
Summary Comments:
On 1/11/2017 Charles D. Bingham and Clifford Meins, Representatives of Micro-Methods Laboratory Inc. performed a limited lead base paint (LBP) inspection of various painted exterior substrates at building 1 of the VA Medical Center, Biloxi, Mississippi. Individual paint chip sampling of various components to be disturbed in upcoming work was performed in ten separate locations as directed by Roy Anderson Corp. The following is a summary of the findings.
Lead was identified in sample numbers 1,2,4,5,6,8,9, and 10 of the samples collected at the time of this inspection (see included report).
OSHA defines LBP as any detectable lead in paint.
HUD defines LBP as any paint or other surface coating that contains lead equal to or in excess of 0.5 percent by weight.
This inspection was conducted according to the State of Mississippi Regulations for Lead-Based Paint Activities, Miss. Code Annotated Sections 49-17-501 through 49-17-531. Inspections were performed by a state certified lead base paint inspector.
MSDEQ Certified Lead Paint Inspector:
Clifford Meins Certification # PBI-1740 Expiration 03/19/2017
Qualifiers:
Total Metals-SW 6010B
The RPD between the sample and sample duplicate exceeded the acceptance limits. The batch was accepted based on the lab controls.RPD04
Lead
7A13014-DUP1
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 3 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
01-North Side Ext. Brick
1701206-01 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B3530 7A13014 01/12/17
11:00
01/13/17
10:51 ppm 1Lead 100 MMG
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 4 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
02-West Side Ext. Brick
1701206-02 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B4080 7A13014 01/12/17
11:00
01/13/17
11:02
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 5 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
03-South Side Ext. Brick
1701206-03 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
ND 01/12/17
11:00 ppm 7A130141Lead 100 MMG 01/13/17
11:07
SW 6010B
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 6 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
04-Chapel South Side Ext. Brick
1701206-04 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B116 7A13014 01/12/17
11:00
01/13/17
11:12
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 7 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
05-North Side Ext. Decorative Railing
1701206-05 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B12900 7A13014 01/12/17
11:00
01/13/17
12:49
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 8 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
06-North Side Ext. Doors & Trim
1701206-06 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B7630 7A13014 01/12/17
11:00
01/13/17
11:18
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 9 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
07-North Side Ext. Columns
1701206-07 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
ND 01/12/17
11:00 ppm 7A130141Lead 100 MMG 01/13/17
11:23
SW 6010B
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 10 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
08-South Side Columns (Sampled Inside)
1701206-08 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B89800 7A13014 01/12/17
11:00
01/13/17
12:02 ppm 20Lead 198 MMG
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 11 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
09-South Side Ext.
1701206-09 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B8460 7A13014 01/12/17
11:00
01/13/17
11:33
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 12 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
ResultAnalyte MRL Batch
Date Time
Prepared
Date Time
Analyzed Method Qualifiers DilUnits Analyst
10-Chapel Ext. Fascia Board Trim
1701206-10 (Paint)
Metals by EPA 6000 Series Methods ICP-AES
SW 6010B69300 7A13014 01/12/17
11:00
01/13/17
12:05 ppm 20Lead 197 MMG
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 13 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
Result MRL Units Level Spike
Result Source
%REC
%REC
Limits RPD
RPD
Limit Qualifiers Analyte
Metals by EPA 6000 Series Methods ICP-AES - Quality Control
Batch 7A13014 - EPA 3050B
Blank (7A13014-BLK1) Prepared: 01/12/17 Analyzed: 01/13/17
Lead ppmND 2.50
LCS (7A13014-BS1) Prepared: 01/12/17 Analyzed: 01/13/17
Lead ppm10.1 2.50 10.0 85-115101
LCS Dup (7A13014-BSD1) Prepared: 01/12/17 Analyzed: 01/13/17
Lead ppm10.8 2.50 10.0 2085-115108 6.91
Duplicate (7A13014-DUP1) Source: 1701206-01 Prepared: 01/12/17 Analyzed: 01/13/17
Lead ppm4760 9.87 3530 20 RPD0429.7
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 14 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
Laboratory Accreditations/Certifications
Code Description Number Expires
01960La Environmental Lab Accreditation Program 06/30/2017C01
TNI01397National Environmental Lab Accreditation Program 06/30/2017C02
MS00021Ms Dept of Health (Coliform) 03/01/2017C03
MS00021Ms Dept of Health (Drinking Water Certificate) 03/01/2017C04
PBF-00000028Ms DEQ Lead Firm Certification 10/16/2017C05
ABI-00001348MsDEQ Asbestos Inspector : C.D. Bingham 03/10/2017C06
AM-011572MsDEQ Air Monitor : C.D. Bingham 04/22/2017C07
ABI-00001821MsDEQ Asbestos Inspector: C. W. Meins 09/29/2017C08
AM-011189MsDEQ Air Monitor : C.W. Meins 04/22/2017C09
ABI-00001345MsDEQ Asbestos Inspector : H.P. Howell 03/10/2017C12
PBI-00003690MsDEQ Lead Paint Inspector : C.D. Bingham 03/18/2017C14
PBI-00001740MsDEQ Lead Paint Inspector : C.W. Meins 03/18/2017C15
Report Definitions
DET Analyte DETECTED
ND Analyte NOT DETECTED at or above the minimum reporting limit
NR Not Reported
RPD Relative Percent Difference
ICV Initial Calibration Verfiication
CCV Continuing Calibration Verification Standard
SSV Secondary Source Verfication Standard
LCS Lab Control Spike - Lab matrix prepared with known concentration of analyte/s of interest analyzed by method.
MS Matrix Spike - Sample prepared with known concentration of analyte/s of interest analyzed by method.
MSD Matrix Spike Duplicate - Duplicate sample prepared with known concentration of anlayte/s of interest analyzed by method.
MRL Minimum Reporting Limit
%REC Percentage Recovery of known concentration added to matrix
Batch Group of samples prepared for analysis not to exceed 20 samples.
Matrix Material containing analyte/s of interest
Surrogate Analyte added to sample to determine extraction efficiency of method.
TNC Too Numerous To Count
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 15 of 18
Project Manager:
Reported:
Roy Anderson Corp.
PO Box 2 [none]
Matt Pringle
VAMC Gulfport, MS Bldg. 1
01/16/17 08:34Gulfport MS, 39502
6500 Sunplex Drive
Ocean Springs, MS 39564
228-875-6420 Phone
228-875-6423 Fax
InitialsFullName
Analyst Initials Key
Charles D. Bingham CDB Clifford W. Meins CWM Michelle M Gallegos MMG Sarah E. Tomek SET Tina Tomek TPT
The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.Page 16 of 18
File details come from the government source that posted it. Updated .