Biloxi VA Reno B1 - Set H.pdf
PDF 6 MB Posted
- Solicitation number
- QSE--36C10F24R50025
About this file
This document appears to be a set of technical drawings and specifications for a ceiling lift system installation as part of the renovation of Building 1 at the Biloxi VA Medical Center in Biloxi, Mississippi.
The key details include:
- The renovation will involve selective demolition, exterior building envelope alterations, and interior renovation of areas within Building 1, primarily on unoccupied floors 3, 4, and 5.
- There will be upgrades to the interior utilities and building systems, including replacement of HVAC, plumbing, electrical, telecommunication systems, chilled water systems, and modifications to the fire protection systems.
- Limited structural, mechanical, and electrical work related to the underside of the 3rd floor structure within the occupied areas of the 2nd floor is required, along with site restoration.
- The awarded contractor will be responsible for monitoring the existing Building 1 foundation system throughout the duration of the project.
- The period of performance is 912 calendar days from receipt of the Notice to Proceed.
- The project magnitude is between $50M to $100M.
- Wage Rate Requirements (Construction) apply.
View the file
Other files
Show 40 more
Latest 50 of 64 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
SIGNOFF / APPROVAL NOTES
1. The facility structure capacity must be able to support the load specified on the installation drawing.
2. Electrical power source provided by the facility, position to be verified in the field.
3. Guldmann Inc. reserves the right to slightly modify the track layout if necessary without Facility approval.
This includes lowering the system to avoid ceiling objects.
4. Guldmann Inc. will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process of which we have not been advised.
5. Modifications of door headers by the facility.
6. Signed drawings are required prior to ordering and installation of ceiling lifts.
This signature of each drawing confirms agreement of all the conditions listed above.
7. Systems are tested at 1.5 times capacity.
550 lbs. tested at 825 lbs.; 770 lbs. tested at 1155 lbs.; 825 lbs. tested at 1238 lbs.; 1100 lbs. tested at 1650 lbs.
MY SIGNATURE BELOW VERIFIES THAT I HAVE:
Reviewed all _____ pages, with a total quantity of _____ room(s), _____ system(s) for the approbation of layout for each room and the approbation of structure for each room.
CUSTOMER
APPROVAL: _____________________________________ DATE: _______________
DATE: DRAWN BY:
Biloxi VA Biloxi VA Reno B1 400 Veterans Ave.
Biloxi, MS 39531
PROJECT ID:103287
Biloxi VA Reno B1
FACILITY SIGNOFF
GUL101
KIT02/05/2016
20 26 26
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
ORIGINAL PROJECT ID: 100098
Revision Schedule
Date Issued by Letter Description
02/22/2016 KIT A ID Added
03/22/2016 TRC B Add Room
04/20/2016 TRC C Add Room
08/12/2016 KIT D Adjusted Layout / Height
02/24/2017 ZLS E Adjusted Layout
07/18/2017 KIT F Adjusted Attachment
06/09/2020 STE G 26 RMs Total / Set Updated / Room Sketches
11/15/2022 CML H New Revit Background / Redrawn To Current Standards / Pages Renumbered / Project ID Number Changed
EACH FIXED RAIL TO
HAVE x1 PARALLEL & x2 PERPENDICULAR
STABILIZERS
ALL JOINTS MUST HAVE x1 PARALLEL & x1
PERPENDICULAR STABILIZER
SEE SPAN CHART
S E
E S
P A
N C
H A
R T
SEE SPAN CHART
± 22°
STABILIZERS CAN BE ROTATED 180°
Fixed rail systems Fixed rail systems must be connected by Guldmann Service Team or by a qualified installer.
A Guldmann class I transformer must be used.
Installation to follow existing rules for authorized electricians and according to IEC/UL 60601-1.
Terminals on transformers Class I Double-insulated UL approved cable must be used (Cable specification: UL category: AVLV2, min.300V, min.
80° C, min. 18AWG (1 mm2 )) Transformer DK-13991 In:
Terminal 1 = N Terminal 2 = 100-115V AC Terminal 3 = 230V AC Terminal 4 = Protective ground Out:
Terminal 5 = 33V AC Terminal 6 = 33V AC
POWER TO BE WITHIN 15 FT OF END OF FIXED RAIL
Guldmann permanent mounted ceiling aluminium rail
Hoist with trolleys movable in rail
Protective Plast Enclosure
UL approved 400V cable, green, min. 14 AWG
Protective Ground
M1
UL approved 400V double isolated cable, min. 18 AWG
ON/OFF
UL approved 400V double isolated cable, min. 18 AWG
T ra n s fo rm e r
D K
-1
Main power Permanent installation Specification of breaker:
≥ 2.5 Amp capacity Line must always be broken
L1
AC/DC charger
Main Motor Control
Emergency Stop
Safety Circuit Emergency down
Motor Function Selector Switch0 1
V A
C
U S
V
A C
P ro te c tiv e G ro u nd
V A
C
V A
C1 A
T
.5
A T
Green Light ON (or ON / OFF - sign)
Licensed Electrician to perform hardwire to transformer
MAX
PROJECTION
MAX DISTANCE BETWEEN VERTICAL SUPPORTS
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
X
X
X
RAIL
RAIL
RAIL
RAIL
RAIL
RAIL
INCH
METER
,23
,7
1,2
39 49 59 68 78 118 137 147 157 177 187 206 215 236 246 264
1,0 1,25 1,5 1,75 2,0 3,0 3,5 3,75 4,0 4,5 4,75 5,25 5,5 6,0 6,25 6,75
MAX. 175 KG (385 LBS.)
MAX. 205 KG (450 LBS.)
MAX. 255 KG (560 LBS.)
MAX. 300 KG (660 LBS.)
MAX. 350 KG (770 LBS.)
MAX. 375 KG (825 LBS.)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A-RAIL
WEIGHT: 2.6 KG/M
(1.75 LBS/FT)
B-RAIL
WEIGHT: 5.0 KG/M
(3.36 LBS/FT)
C-RAIL
WEIGHT: 6.0 KG/M
(4.03 LBS/FT)
(2 1/2")
62 mm.
(2
/4
,5 m m
(2 1/2")
62 mm.
(5 m m
(2 1/2")
62 mm.
(6
/3 m m
A
B
C
RAIL MAX. 400 KG (880 LBS.)
X
X
X
A
B
C
RAIL MAX. 500 KG (1100 LBS.)
X
X
X
7,25
8,0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CENTERED IN DOORWAY
76.2 mm (3")
.2 m m
DOOR JAM
MODIFICATIONS TO DOOR
FRAME/HEADER DONE BY FACILITY
AND COORDINATED WITH GULDMANN
PATIENT LIFT
m m
/2
A
B
C
D
E
F
G
H
I
J
K
Ceiling bracket standard
A / B / C
Basic High M
Basic High M
Dimensions
205 mm
580 mm
345 mm
24 mm
58.5 / 125 / 170 mm
156 mm
184 mm
425 mm
2500 mm
970 mm
340 mm
8"
22.8"
13.5"
1.5"
2.2 / 4.9 / 6.6"
6.29"
7.2"
16.75"
98"
38"
13.3"
H
A
E D
F
C
G I
B
K J
Electrical parts On/off : Automatically on activation Motor consumption : 24V DC5W Periodic load : 10/90 Power supply : 33V AC, 2.5A Supply voltage transformer : 115/230 V AC
Classification, tightness Hand control : IP 54
Weight and materials GH Switch track 90˚ : 23 lbs (10,4 kg) Switch track railpart : Anodized aluminum Plateparts : Stainless steel m m
/8
551 mm (21 3/4")
550 mm (21 5/8")
50 mm (2") m m
/2
MAX. WEIGHT LIMIT 560 LBS
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
Biloxi VA Reno B1
GEN. INFO
GUL102
KIT02/05/2016
PROJECT ID:103287
NTS
BRACING + SUPPORT
NTS
GH3 TRANSFORMER
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
NTS
RAIL SPAN CHART
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
WAFFLE, SPAN = 19"
NTS
DOOR HEADER HOIST PASSTHROUGH
NTS
GH3 PATIENT SLING DIMS
NTS
GH SWITCHTRACK
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
SPRING PLATE
AVAILABLE FOR A & B RAIL
FLUSH CEILING PROFILE LIP IS 7/16" X 3/8"
CUT 12 - 15 MM OF THE 2 LONGITUDE
SCREW FOR
PROFILE END
175 mm (6 3/4") 3 mm (1/8")
99 mm (4")
MINIMUM
100 mm (4")
WALL
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
GEN. INFO
GUL102.1
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
NTS
FLUSH CEILING PROFILE
NTS
COMBI-LOCK (375 KG / 825 LBS MAX)
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
40° T O 90°
0°
90°
1A B
8,9
DRAWINGS APPROVED FOR THE GULDMANN
GH-3 LIFTER SYSTEM STANDARD INSTALLATION
OF SUPPORT AND CONNECTION TO WAFFLE
DECK.
SYSTEMS INSTALLED FOR 1100 POUNDS WILL BE
TESTED AT 1650 POUNDS.
SYSTEMS INSTALLED FOR 770 POUNDS WILL BE
TESTED AT 1155 POUNDS.
SYSTEMS INSTALLED FOR 550 POUNDS WILL BE
TESTED AT 825 POUNDS.
V A
R
IE
S
M A
X
9,11
HVAC / MECH
BASEPLATE x4
STABILIZERS x3
STABILIZERS
± 22°
BRIDGE / RAIL TOP
BRIDGE SECTION
GULDMANN RAIL
SPAN
OPTIONAL B
DETAIL B
DETAIL A
OPTIONAL A
8,9
WAFFLE DECK / CONCRETE BEAM
DESCRIPTIONITEM NUMBERTAG
1-5/8" X 10' B2B STRUT SLOTTED20070821
3/8" B7 THREADED RODHTHR037 12B72
STABILIZER BRACKET KIT - GULDMANN5504393
1" Ø-6013-T6 AL TUBE - GULDMANN550481-US4
CEILING BRACKET KIT - GULDMANN5504355
2 HOLE 90 DEG. BRACKETP10266
MQM-F WINGNUT 3/8"3778827
3/8" X 1-1/4" HEX BOLT4117648
3/8" X 1-1/4" X 1/8" WASHER (THICK)111012739
3/8" X 3-3/4" KB1223145610
3/8" NYLOCK NUT113702411
3/8" BEVELLED WASHER3387312
3/8" HEX NUT41175213
MQZ-L BASEPLATE 3/8"37063214
MQA-F SADDLE NUT 3/8"37788515
( USED AS NEEDED )
( OPTIONAL )
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
ATTACHMENT
GUL103
KIT02/05/2016
PROJECT ID:103287
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
GUL104
GUL104
/4
B .O
H
O
IS
T
/2
B .O
T
R A
V E
R S
E
C E
IL
IN
G
C O
M B
I- L O
C K
/2
A -R
A
IL
/8
T .O
T
R A
V E
R S
E
/8
T .O
H
O
IS
T
8" MIN.
/4
/2
/8
TRAVERSE (B-RAIL)
CEILING
/4
/2
/4
M
A X
A-RAIL
/2
/8
COMBI-LOCK
COMBI-BRACE
CEILING
TRAVERSE (B-RAIL)
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
PROJECT DETAILS
GUL104
KIT02/05/2016
PROJECT ID:103287
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
1" = 1'-0"
TYP SYSTEM HEIGHTS
1 1/2" = 1'-0"
CEILING / HOIST DETAIL
3" = 1'-0"
COMBI-LOCK DETAIL
Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
OVERALL - 3rd Floor
GUL105
CML11/15/2022
PROJECT ID:103287
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
A rail
Revision Schedule
Date Issued by Number
11/15/2022 CML H
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
1" = 20'-0"
OVERALL - 3rd Floor
HOIST COVERAGE AREA5.
Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
OVERALL - 4th Floor
GUL106
CML11/15/2022
PROJECT ID:103287
Revision Schedule
Date Issued by Number
11/15/2022 CML H
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
1" = 20'-0"
OVERALL - 4th Floor
HOIST COVERAGE AREA5.
/4
/8
10' - 11 3/4" 3 7/8"
/8
2' - 3"
3'
/8
2' - 10 1/8" 1"
/8
6' - 1 3/4"
90°
SWITCHTRACK
60° RIGHT
45°
30°
60°
45°
Patient Room 1
4B114
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 1
GUL107
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
REFERENCE ROOMS
3B114 4B114
3/8" = 1'-0"
PATIENT ROOM 1
1' - 4 3/8"
/2
3' - 5 1/2"
3' - 2 3/8"
1' - 11"
/8
9' - 4 1/4"
8' - 4 3/8" 10"
/8
SWITCHTRACK
90° LEFT
30°
45°
45°
Patient Room 2
4B116
GUL104
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 2
GUL108
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
REFERENCE ROOMS
3B116 4B116
1/2" = 1'-0"
PATIENT ROOM 2
6' - 5"
/8
/2
/8
3 7/8" 10' - 9 1/8"
2' - 0 7/8"
1' - 2 3/8"
/4
2' - 0 1/2"
/2
SWICHTRACK
60° RIGHT
90°
60°
Patient Room 3
4B118
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 3
GUL109
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
REFERENCE ROOMS
3B118 4B118
1/2" = 1'-0"
PATIENT ROOM 3
2' - 0 1/2"
/4
SWITCHTRACK
60° LEFT
60°
90°
6' - 5"
/2
/8
/8
10' - 10 5/8" 3 7/8"
2' - 0 7/8"Patient Room 4
4B119
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 4
GUL110
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
REFERENCE ROOMS
3B119 4B119
1/2" = 1'-0"
PATIENT ROOM 4
2' - 0 1/2"
3' - 6 7/8"
/2
/8
/2
3 7/8" 11' - 2 1/4"
/8
30°
90°
SWITCHTRACK
60° RIGHT
30°
30°
30°
Patient Room 5
4B123
7' - 1 5/8"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 5
GUL111
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
REFERENCE ROOMS
3B123 4B123
1/2" = 1'-0"
PATIENT ROOM 5
Patient Room 6
4B124
/2
/8
11' - 1 3/4" 3 7/8"
/8
7' - 1 3/8"
/8 "2' - 0 1/2"
3' - 3 1/4"
1' - 1 1/4"
/4
SWITCHTRACK
60° LEFT
90°
30°
30°
30°
30°
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 6
GUL112
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3B124 4B124 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
1/2" = 1'-0"
PATIENT ROOM 6
SWITCHTRACK
90° LEFT
45°
45°
1" 4' - 10 3/8"
/4
2' - 0 3/8"
9' - 6 1/4"
8' - 4 3/8" 10 3/4"
/2
"Patient Room 7 (Neg. Press.)
4B111
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 7
GUL113
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3B111 4B111 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
3/8" = 1'-0"
PATIENT RM 7 (Neg. Press.)
/8
/8
M A
X
3 7/8" 10' - 3 5/8"
1' - 1 1/2"
2' - 6 1/2"
/4
3' - 11 3/4"
1' - 6 1/2"
60°
30°
90°
30°
SWITCHTRACK
60° RIGHT
Patient Room 8
4A117
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 8
GUL114
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3A117 4A117 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
1/2" = 1'-0"
PATIENT ROOM 8
11' - 3 1/2" 3 7/8"
/8
M A
X
/2
1' - 7 7/8"
1' - 0 3/8"
3' - 9 1/2"
/2
2' - 6 1/2"
60°
90°
30°
SWITCHTRACK
60° LEFT
30°
Patient Room 9
4A118
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 9
GUL115
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3A118 4A118 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
1/2" = 1'-0"
PATIENT ROOM 9
Patient Room 10
4A122
/8
/8
3 7/8" 11' - 8 1/8"
/2
2' - 0 5/8"
1' - 8 7/8"
6' - 7 7/8"
SWITCKTRACK
60° RIGHT
90°
30°
30°
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 10
GUL116
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3A122 4A122 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
1/2" = 1'-0"
PATIENT ROOM 10
Patient Room 11
4A123
/2
/8
11' - 10 7/8" 3 7/8"
/8
1' - 8 5/8"
/2
1' - 11"
1' - 2"
/4
6' - 9 3/8"
SWITCKTRACK
60° LEFT
90°
30°
30°
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 11
GUL117
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3A123 4A123 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
1/2" = 1'-0"
PATIENT ROOM 11
Bariatric Patient Room 12
4A125
3 7/8" 12' - 9 5/8"
/2
/8
/2
2' - 9 7/8"
/2
3' - 5 3/8"
2' - 0 5/8"
3' - 0"
/4
30°
60°
SWITCHTRACK
60° RIGHT
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP BARI PATIENT ROOM 12
GUL118
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
03/22/2016 TRC B
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3A125 4A125 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
3/8" = 1'-0"
BARI PATIENT ROOM 12
Bariatric Patient Room 13
(Neg. Press.)
4A131
1' - 4 3/4"
3' - 0 3/8" 7' - 7" 1"
/4
/8
M A
X
SWITCHTRACK
60° RIGHT
30°
3 7/8" 13' - 1 1/2"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS
Biloxi VA Reno B1
TYP PATIENT ROOM 13
GUL119
KIT02/05/2016
PROJECT ID:103287
Revision Schedule
Date Issued by Number
02/22/2016 KIT A
08/12/2016 KIT D
02/24/2017 ZLS E
07/18/2017 KIT F
06/09/2020 STE G
11/15/2022 CML H
REFERENCE ROOMS
3A131 4A131 HOIST = 550 LBS1.
FLUSH RECESSED / TYPE P2.
CEILING HEIGHT = 9' - 0"3.
AFF TO DECK = 13' - 6"
ATTACHMENT TYPE =4.
WAFFLE, SPAN = 19"
w/ SWITCHTRACK
HOIST COVERAGE AREA5.
CENTER IN DOORWAY6.
CENTER TO TOILET7.
Stabilizers
Combi-lock
B rail
Hoist Transformer
Hoist
Wall switch for TTBL/SWT
KEY
Ceiling bracket, Extended
A rail
3/8" = 1'-0"
BARI PATIENT RM 13 (Neg. Press.)
| Sheets |
| GUL101 - FACILITY SIGNOFF |
| GUL102 - GEN. INFO |
| GUL102.1 - GEN. INFO |
| GUL103 - ATTACHMENT |
| GUL104 - PROJECT DETAILS |
| GUL105 - OVERALL - 3rd Floor |
| GUL106 - OVERALL - 4th Floor |
| GUL107 - TYP PATIENT ROOM 1 |
| GUL108 - TYP PATIENT ROOM 2 |
| GUL109 - TYP PATIENT ROOM 3 |
| GUL110 - TYP PATIENT ROOM 4 |
| GUL111 - TYP PATIENT ROOM 5 |
| GUL112 - TYP PATIENT ROOM 6 |
| GUL113 - TYP PATIENT ROOM 7 |
| GUL114 - TYP PATIENT ROOM 8 |
| GUL115 - TYP PATIENT ROOM 9 |
| GUL116 - TYP PATIENT ROOM 10 |
| GUL117 - TYP PATIENT ROOM 11 |
| GUL118 - TYP BARI PATIENT ROOM 12 |
| GUL119 - TYP PATIENT ROOM 13 |
File details come from the government source that posted it. Updated .