Drawings - Plumbing - 2.pdf
PDF 12 MB Posted
- Solicitation number
- QSE--36C10F24R50025
About this file
This document appears to be a solicitation for the Biloxi Building 1 Renovation project in Biloxi, MS. The Department of Veterans Affairs Office of Construction and Facilities Management is seeking a contractor to provide all necessary supervision, labor, materials, transportation, and equipment to complete the renovation of Building 1. The project scope includes selective demolition, exterior building envelope alterations, and interior renovation of floors 3, 4, and 5, as well as upgrades to HVAC, plumbing, electrical, telecommunications, chilled water, and fire protection systems. The period of performance is 912 calendar days from the notice to proceed, and the project magnitude is estimated between $50M to $100M. Wage Rate Requirements (Construction) apply. The solicitation number is QSE-36C10F24R50025.
View the file
Other files
Show 40 more
Latest 50 of 64 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
G
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
EXISTING 1-1/4"
OXYGEN RISER UP
WITH SHUT-OFF
VALVE IN RISER.
EXISTING 1/2" OXYGEN UP
TO ZONE VALVE ABOVE.
NEW 1-1/4" O, RISER UP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL301
EXISTING CRAWL SPACE -MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 150 238
KEYED NOTES:
1. CONNECT TO EXISTING 2" OXYGEN PIPING.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTORS SHALL REVIEW ROUTING OF PIPING
PRIOR TO BID. ROUTING SHOWN IS ONE POTENTIAL
ROUTE WITH FINAL ROUTE UP TO INSTALLING
CONTRACTOR TO DETERMINE.
3. CONTRACTORS SHALL COORDINATE ROUTING OF PIPING
WITH EXISTING CONDITIONS.
4. REMOVE ALL EXISTING DENTAL VACUUM PIPING
SERVING THE FIRST FLOOR AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED.
Revisions: Date:
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
EXISTING 1 1/4"O UP & DN
EXISTING 1 1/4" MA & 1 1/2" MV
UP
PROVIDE SHUT-OFF
VALVES.
UPUP & DN
UP
2" MV CAPPED
FOR FUTURE USE
EXISTING O, MA, MV UP
TO 2ND FLOOR
BIOMEDICAL DEPT.
EXISTING SHUT-OFF VALVES
FOR SERVICES TO 2ND FLOOR
BIOMEDICAL DEPT. EXISTING 0, MA, & MV SERVICES
TO EAST WING
1" O, 1" MA
REMOVE EXISTING DENTAL AIR RISER FROM THE
FIRST FLOOR BACK TO THE DENTAL AIR
COMPRESSORS AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED AND IS OPERATIONAL.
VERIFY WITH VA PRIOR TO REMOVAL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL302
EXISTING 1ST FLOOR - MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 151 238
KEYED NOTES:
1. CONNECT TO EXISTING 3/4" O & 3/4" MA
PIPING DOWNSTREAM OF EXISTING SHUT-OFF
VALVES. CAP EXISTING O & MA AT SHUT-OFF VALVES.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. REFER TO PL501 AND PL502 FOR DETAILS.
3. REFER TO PL507 FOR RISER DIAGRAMS.
4. REMOVE ALL EXISTING DENTAL AIR AND DENTAL
VACUUM PIPING ON THE FIRST FLOOR AFTER THE
NEW DENTAL LAB HAS BEEN COMPLETED.
5. REFER TO DRAWING AE102 FOR INFORMATION
REGARDING PHASING OF WORK ON THE SECOND
FLOOR.
1 2 3 4 5 6 7 8 9
11 12
14 15 16 17 18 19 20 21 22
G
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
PROVIDE SHUT-OFF
VALVES AND CAP
FOR FUTURE USE.
TURN UP/DN..
1"O, 1" MA, 2" MV
CAPPED.
REMOVE EXISTING DENTAL AIR RISER FROM
THE FIRST FLOOR BACK TO THE DENTAL AIR
COMPRESSORS AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED AND IS OPERATIONAL.
VERIFY WITH VA PRIOR TO REMOVAL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL303
EXISTING 2ND FLOOR - MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 152 238
KEYED NOTES:
1. EXISTING 1 1/4" OXYGEN PIPING SHALL CONTINUE TO SERVE
THE 1ST & 2ND FLOORS. CAP RISER BELOW 3RD FLOOR & PROVIDE
WITH A SHUT-OFF VALVE.
2. CONNECT TO EXISTING 1 1/2" MA & 1 1/2" MV.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. REFER TO PL501 AND PL502 FOR DETAILS.
3. REFER TO PL507 FOR RISER DIAGRAMS.
4. REFER TO DRAWING AE102 FOR INFORMATION REGARDING
PHASING OF WORK ON THE SECOND FLOOR.
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
FEC
FEC FEC
ZONE VALVE
MEDICAL GAS
AREA ALARM
PROVIDE
SHUT-OFF VALVES.
ZONE
VALVE
TURN UP/DN..
NEW MA & MV
UP/DN..
SHUT-OFF
VALVES
SHUT-OFF
VALVES
SHUT-OFF
VALVES
1 1/4" O, 1 1/2" MA,
2" MV
REMOVE EXISTING DENTAL AIR RISER FROM
THE FIRST FLOOR BACK TO THE DENTAL AIR
COMPRESSORS AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED AND IS OPERATIONAL.
VERIFY WITH VA PRIOR TO REMOVAL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL304
3RD FLOOR - MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 153 238
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. REFER TO PL501 AND PL502 FOR DETAILS.
3. REFER TO PL507 FOR RISER DIAGRAMS.
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
ZONE VALVE
ZONE
VALVE
1 1/2" LA & 1 1/2" DA
UP TO 5TH FLOOR
PROVIDE
SHUT-OFF VALVES.
DENTAL AIR
TURN UP/DN..
NEW MA & MV
UP/DN..
LA
SHUT-OFF VALVE IN
VERTICAL. ( TYP.)
SHUT-OFF
VALVES
1 1/4"O, 1 1/2"
MA, 2"MV
UP TO
WCO
UP TO
WCO
1 1/2" DV UP TO WCO
1 1/2" DV UP TO WCO
2" DV UP
REMOVE EXISTING DENTAL AIR RISER FROM
THE FIRST FLOOR BACK TO THE DENTAL AIR
COMPRESSORS AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED AND IS OPERATIONAL.
VERIFY WITH VA PRIOR TO REMOVAL.
2" DV FROM
DENTAL INTO TANK
2" DV FROM
PUMP INTO TANK
MEDICAL GAS
AREA ALARM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL305
4TH FLOOR - MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 154 238
KEYED NOTES:
1. 1/2" DA UP TO DENTAL CHAIR FLOOR BOX.
2. 1/2" LA UP TO DENTAL LAB. COORDINATE
EXACT LOCATION WITH DENTAL LAB
EQUIPMENT LAYOUT, STRUCTURE, AND
RESIDENT ENGINEER.
3. 1-1/2" DV UP TO DENTAL CHAIR FLOOR BOX.
4. 1/2" DA UP TO SIDE ACCESSORY CONSOLE.
5. 1" LA PIPING UP TO DENTAL LAB.
COORDINATE EXACT LOCATION WITH DENTAL
LAB EQUIPMENT LAYOUT, STRUCTURE, AND
RESIDENT ENGINEER.
6. CONTRACTOR TO INSTALL VA PROVIDED
SEPARATOR TANK. CONTRACTOR SHALL
PROVIDE ALL NECESSARY COMPONENTS FOR
COMPLETE INSTALLATION. COORDINATE
REQUIREMENTS WITH VA.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND
NOTES.
2. REFER TO PL501 AND PL502 FOR DETAILS.
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
ZONE VALVE
1 1/2" LA & 1 1/2" DA
DOWN TO 4TH FLOOR
PROVIDE SHUT-OFF
VALVES.
NEW MA & MV
DN..
NEW MA & MV
UP.
LA
1 1/4" O DN, 1 1/2"MA, 2"
MV UP/DN
UP
UP
UP & DN
WCO
WCO
WCO
WCO
REMOVE EXISTING DENTAL AIR RISER FROM
THE FIRST FLOOR BACK TO THE DENTAL AIR
COMPRESSORS AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED AND IS OPERATIONAL.
VERIFY WITH VA PRIOR TO REMOVAL.
LOCATE Y-SPLIT OUTLET
AT THESE STATIONS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL306
5TH FLOOR - MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 155 238
KEYED NOTES:
1. CAP 2" MV & 1 1/2" MA FOR FUTURE USE.
2. 1/2" LA PIPING DOWN TO 4TH FLOOR.
COORDINATE EXACT FLOOR PENETRATION
LOCATION, PIPING TERMINATION, AND OUTLET
TYPE, LOCATION, AND ELEVATION WITH DENTAL
LAB EQUIPMENT/FURNITURE, STRUCTURE, AND
RESIDENT ENGINEER.
3. 1" LA PIPING DOWN TO 4TH FLOOR.
COORDINATE EXACT ROUTE OF LA PIPING WITH
VACUUM TUBING SYSTEM LOCATED WITHIN
ISLAND CABINETRY.COORDINATE EXACT FLOOR
PENETRATION LOCATION, PIPING TERMINATION,
AND OUTLET TYPE, LOCATION, AND ELEVATION
WITH DENTAL LAB EQUIPMENT/FURNITURE AND
VENDOR (LOC), STRUCTURE, AND RESIDENT
ENGINEER.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. REFER TO PL501 AND PL502 FOR DETAILS.
F
E
D
C
B
A
7.4
F.8
F.3
B.4
B.7
D.8
D.2
B.8
B.2
10.8 12.2
5.1
EXISTING 1-1/2" MEDICAL AIR
EXISTING 2" MEDICAL VACUUM
NEW 1-1/2" DENTAL AIR
NEW 1 1/2"MA, 2"MV, 1 1/2" LA,
& 1 1/2" DA DOWN TO 5TH FLOOR
NEW MA & MV
DN..
NEW 1-1/2" LABORATORY AIR
DN
2" DV EXHAUST TO OUTSIDE WEATHER
CAP. COORDINATE INSTALLATION WITH
MECHANICAL CONTRACTOR. EXHAUST
OUTLET TO BE 25 FEET MINIMUM FROM
HVAC INTAKES.
INSTALL VA PROVIDED PUMP. CONTRACTOR
SHALL PROVIDE ALL NECESSARY
COMPONENTS FOR COMPLETE INSTALLATION.
COORDINATE REQUIREMENTS WITH VA AND
ELECTRICAL.
REMOVE EXISTING DENTAL AIR RISER FROM
THE FIRST FLOOR BACK TO THE DENTAL AIR
COMPRESSORS AFTER THE NEW DENTAL LAB
HAS BEEN COMPLETED AND IS OPERATIONAL.
VERIFY WITH VA PRIOR TO REMOVAL.
REVISE EXISTING PIPING ROUTE FOR NEW
MECHANICAL AND DUCT INSTALLATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL307
ATTIC - MED GAS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 156 238
KEYED NOTES:
1. 1 1/2" LA CONNECTION TO EXISTING DENTAL
AIR COMPRESSOR. PROVIDE PRESSURE REDUCING VALVE
SET AT 50 PSI.
2. 1 1/2" DA CONNECTION TO EXISTING DENTAL AIR
COMPRESSOR. PROVIDE PRESSURE REDUCING VALVE SET
AT 140 PSI.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
12 13
B
A
B.4
B.2
12.2
UP & DN
4" SAN UP
& DN
4"
VENT
UP
2" CW UP
1 1/2" CW
UP
UP
UP
UP
UP
UP & DN
16 17
D
D.2
4" SAN
UP & DN
3" VENT
UP
UP
UP
UP
UP
UP
UP
UP
12 13
B.4
B.2
12.2
4" SAN
DN
UP1" CW,
1/2" HW,
1/2" HWR
DN
UP
3 4
D
C
D.2
WCO
4" SV UP
4" SS DN
F
E
D.8
1 1/2" CW DN
1" HW DN
1" CW DN
1/2" HWR DN
DN
4" SV
UP
UP & DN
19 20 21 22
C
B
B.4
B.7
B.8
B.2
4" SAN
DN
2" SAN
DN
2" SS DN
WCO
4" SAN
DN
2" CW DN
1 1/2"HW DN
UP
UP
1 1/2"HWR DN
MULTIPLE
TRAP PRIMER
DN
4" SV UP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL401
ENLARGED PLANS - PLUMBING RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 157 238
KEYED NOTE
1. 1/2" CW BELOW SLAB TO TRAP.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
10 11 12 13
F
F.8
F.3
10.8 12.2
DN
UP
DN
3" SS
3" SS DN
2" SV UP
WCO
2" SV
4" SS
DN
2" CW DN
1 1/2" HW DN
1 1/2" HWR DN
1" CW UP TO
HOSE BIBBS IN
ATTIC.
UP
MULTIPLE
TRAP PRIMER
UP
3" SS UP TO EXISTING
FLOOR DRAIN
2 3 4
C
B
B.4
B.7
B.8
B.2
4" VENT
UP
UP & DN
WCO
UP
UP
UP
UP
UP
SERVICES TO
PATIENT
ROOM SINK
CS-2
UP
UP
TP-2
UP
UP
G
F
E
F.8
F.3
D.8
4" SAN
UP & DN
4" VENT
UPUP
UP
UPUP
UP
UP
UP
UP & DN
TP-2
TP-2
BFP
1/2" HWR UP
1/2" HW UP
1/2" CW UP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL402
ENLARGED PLANS - PLUMBING RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 158 238
KEYED NOTE
1. 1/2" CW BELOW SLAB TO TRAP
2. PROVIDE 3/4" DRAIN WITH SOLENOID VALVE THEN
MANUAL SHUT-OFF VALVE EXTENDED TO FLOOR SINK (OR
MOP SINK) TO "HEAT AND FLUSH" DOMESTIC HOT WATER
LINE. SOLENOID VALVE TO BE WIRED TO BAS FOR REMOTE
OPERATION AND MONITORING. COORDINATE VALVE
SELECTION AND LOCATION WITH OWNER AND
TEMPERATURE CONTROL CONTRACTOR.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38
ALTERNATE NO.2 FOR REQUIREMENTS OF
DEDUCT ALTERNATE OF THE DIALYSIS
BOXES INDICATED ON THIS SHEET.
1 2 3 4 5 6
F
E
F.8
F.3
D.8
4" SV UP
4" SAN
UP & DN
4" SV UP
4" SAN
UP & DN
4" SAN
UP &
DN
4" SAN
UP & DN
1/2" HWR
UP
WC
UP
UP UP
UP
WCO
UP
UP UP & DN
UP
UP
DN
UPUP
UP
UP & DN
CS-2
CS-2
CS-2
CS-2
UPUP
UP
TP-2
TP-2
TP-2
DNTP-2
1/2" HW
UP
1/2" CW
UP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL403
ENLARGED PLANS - PLUMBING RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 159 238
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38
ALTERNATE NO.2 FOR REQUIREMENTS OF
DEDUCT ALTERNATE OF THE DIALYSIS
BOXES INDICATED ON THIS SHEET.
19 20 21
C
B
B.4
B.7
B.8
B.2
UP
DN
UP & DN
DN
UP
DN
UP
UP
CS-2
TP-2
UP
UP
UP
UP
UP
UP
UP
1 2 3 4
C
B
B.4
B.7
B.8
B.2
DN
BAL V
4" SS DN
4 5
F
F.8
F.3
WCO
87.4
F.8
F.3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL404
ENLARGED PLANS - PLUMBING RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 160 238
KEYED NOTES:
1. PROVIDE 1/2" CW, 1/2" HW, AND 1 1/2" WASTE
CONNECTIONS FOR SINK LOCATED IN SIDE ACCESSORY
CONSOLE. COORDINATE ROUGH-IN REQUIREMENTS
WITH EQUIPMENT PROVIDER.
2. PROVIDE P-710 HANDHELD EYEWASH STATION WITH
MIXING VALVE MOUNTED BELOW COUNTER.
COORDINATE PIPING, MOUNTING BRACKET, UNIT
LOCATION, AND MIXING VALVE LOCATION WITH SINK
AND EQUIPMENT.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38
ALTERNATE NO.2 FOR REQUIREMENTS OF
DEDUCT ALTERNATE OF THE DIALYSIS BOXES
INDICATED ON THIS SHEET.
MEDICAL GAS MOUNTING HEIGHT DETAIL
NOT TO SCALE
PIPE PENETRATION THROUGH WALL BELOW GRADE
NOT TO SCALE
(P-809) DIALYSIS BOX DETAIL
NOT TO SCALE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL501
DETAILS - PLUMBING RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 161 238Revisions: Date:
PORTABLE
WATER
ANALYZER
AUTOMATIC SPRINKLER SYSTEM SECTIONAL
CONTROL VALVE AND INSPECTOR'S TEST
VALVE AND DRAIN ASSEMBLY DETAIL
FLOOR MOUNTED HANDICAPPED, WATER CLOSET DETAIL
WALL HUNG HANDICAPPED, WATER CLOSET DETAIL
MEDICAL GAS PIPING AT OUTLETS 4
5a
3 5WATER MONITORING SYSTEM DETAIL
NOT TO SCALE
5b
NOT TO SCALE
NOT TO SCALE NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL502
DETAILS - PLUMBING RENOVATE BUILDING 1
10/27/2023 SCOPRZ AARMEY 162 238Revisions: Date:
1ST FLOOR 0'-0"
2ND FLOOR 13'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
CS-2
CS-2
EXISTING FLOOR
DRAIN
EXISTING
4" VTR
EXISTING
4" VTR
EXISTING
4" VTR
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
4" VTR
4" VTR
4" VTR
CONNECT TO
EXISTING 4" VTR
EXISTING 4" VTR
CS-2
EXISTING VENT PIPING IN
ATTIC WHICH IS TO BE
REMOVED AS EXISTING
RISERS ARE REMOVED FROM
SERVICE. (TYPICAL)
REMOVE EXISTING
4" VTR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL505
OVERALL SANITARY RISER RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 163 238
KEYED NOTES:
1. PROVIDE 1/2" CW, 1/2" HW, AND 1 1/2" WASTE
CONNECTIONS FOR SINK LOCATED IN SIDE ACCESSORY
CONSOLE. COORDINATE ROUGH-IN REQUIREMENTS
WITH EQUIPMENT PROVIDER.
GENERAL SHEET NOTES:
1. REFER TO FLOOR PLANS FOR SIZES.
2. REFER TO PL601 FOR SYMBOLS AND NOTES.
3. REFER TO PL508, PL509, PL510, AND PL511 FOR
ENLARGED RISER DIAGRAMS.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38
ALTERNATE NO.2 FOR REQUIREMENTS OF
DEDUCT ALTERNATE OF THE DIALYSIS BOXES
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
CS-2
CS-2
CS-2
CS-2
CS-2
CS-2
CS-2
CS-2
CS-2
CS-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
TP-2
CS-2
CS-2
CS-2
CS-2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL506
OVERALL WATER RISER RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 164 238
KEYED NOTES:
1. PROVIDE 1/2" CW, 1/2" HW, AND 1 1/2" WASTE
CONNECTIONS FOR SINK LOCATED IN SIDE
ACCESSORY CONSOLE. COORDINATE ROUGH-
IN REQUIREMENTS WITH EQUIPMENT
PROVIDER.
2. PROVIDE P-710 HANDHELD EYEWASH STATION
WITH MIXING VALVE MOUNTED BELOW
COUNTER. COORDINATE PIPING, MOUNTING
BRACKET, UNIT LOCATION, AND MIXING VALVE
LOCATION WITH SINK AND EQUIPMENT.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. REFER TO FLOOR PLANS FOR SIZES.
3. REFER TO PL508, PL509, PL510, AND PL511 FOR
ENLARGED RISER DIAGRAMS.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38
ALTERNATE NO.2 FOR REQUIREMENTS OF
DEDUCT ALTERNATE OF THE DIALYSIS BOXES
ATTIC 66'-0"
5TH FLOOR 52'-0"
4TH FLOOR 39'-0"
3RD FLOOR 26'-0"
2ND FLOOR 13'-0"
1ST FLOOR 0'-0"
EXISTING
EXISTING
EXISTING
EXISTING
VA PROVIDED,
CONTRACTOR INSTALLED
SEPARATOR TANK
EXISTING
VA PROVIDED,
CONTRACTOR INSTALLED
VACUUM PUMP
MEDICAL GAS
AREA ALARM
MEDICAL GAS
AREA ALARM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL507
OVERALL MED GAS RISER RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 165 238
GENERAL NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. REFER TO FLOOR PLANS FOR SIZES NOT SHOWN.
3. REFER TO FLOOR PLANS PL301, PL302, AND PL307 FOR SYSTEM CONNECTIONS.
4. PROVIDE MEDICAL GAS RISER DIAGRAM IN SHOP DRAWING SUBMITTAL FOR REVIEW. VERIFY ROUTING IN FIELD PRIOR TO SUBMITTING DRAWINGS.
WCO
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
TO EXISTING VTR
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
TP-2
TP-2
CS-2
WCO
WCO
WCO
WCO
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
FD-M
FD-M
2" VTR
TP-2
TP-2
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR
39'-0"
5TH FLOOR 52'-0"
TP-2
TP-2
TP-2
TP-2
WCO
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3/4" HW DRAIN LINES WITH
SOLENOID VALVE THEN MANUAL
SHUT-OFF VALVE EXTENDED TO
FLOOR SINK (OR MOP SINK) TO
"HEAT AND FLUSH" DOMESTIC HOT
WATER LINE.
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3/4" HW DRAIN LINES WITH
SOLENOID VALVE THEN MANUAL
SHUT-OFF VALVE EXTENDED TO
FLOOR SINK (OR MOP SINK) TO
"HEAT AND FLUSH" DOMESTIC
HOT WATER LINE.
TP-2
TP-2
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
BFP
BFP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL508
PLUMBING RISERS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 166 238
SIMILAR RISERS:
P/3, P/4, P/7, P/8, P/9
SIMILAR RISERS:
P/3, P/4, P/7, P/8, P/9
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38 ALTERNATE
NO.2 FOR REQUIREMENTS OF DEDUCT ALTERNATE
OF THE DIALYSIS BOXES INDICATED ON THIS SHEET.
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
WCO
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3/4" HW DRAIN LINES WITH SOLENOID
VALVE THEN MANUAL SHUT-OFF VALVE
EXTENDED TO FLOOR SINK (OR MOP
SINK) TO "HEAT AND FLUSH" DOMESTIC
HOT WATER LINE.
WCO
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL509
PLUMBING RISERS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 167 238
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS
SPECIFICATION SECTION 01 00 00.1.38 ALTERNATE
NO.2 FOR REQUIREMENTS OF DEDUCT ALTERNATE
OF THE DIALYSIS BOXES INDICATED ON THIS SHEET.
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
FLOOR 3 26'-0"
FLOOR 4 39'-0"
FLOOR 5 52'-0"
WCO
2ND FLOOR 13'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
2ND FLOOR 13'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL510
PLUMBING RISERS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 168 238
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
CS-2
TP-2
TP-2
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
6TH FLOOR 66'-0"
3/4" HW DRAIN LINES WITH SOLENOID
VALVE THEN MANUAL SHUT-OFF VALVE
EXTENDED TO FLOOR SINK (OR MOP
SINK) TO "HEAT AND FLUSH" DOMESTIC
HOT WATER LINE.
CS-2
TP-2
TP-2
FILTER
BFP
2ND FLOOR 13'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
CS-2
CS-2
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
CS-2
CS-2
3RD FLOOR 26'-0"
PATIENT ROOMS
3&4, 5&6, 8&9 10&11
ARE SIMILAR
3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
CS-2
CS-2
CS-2
CS-2
PATIENT ROOMS
3&4, 5&6, 8&9, 10 &11
ARE SIMILAR 3RD FLOOR 26'-0"
4TH FLOOR 39'-0"
5TH FLOOR 52'-0"
CS-2
CS-2
CS-2
CS-2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL511
PLUMBING RISERS RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 169 238
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTOR SHALL SET ALL BALANCE VALVES TO
0.5GPM UNLESS NOTED OTHERWISE.
DEDUCT ALTERNATE:
1. REFER TO GENERAL REQUIREMENTS SPECIFICATION
SECTION 01 00 00.1.38 ALTERNATE NO.2 FOR
REQUIREMENTS OF DEDUCT ALTERNATE OF THE
DIALYSIS BOXES INDICATED ON THIS SHEET.
PACKAGE BOOSTER PUMP SCHEDULE
MARK LOCATION AREA AND/OR
BLDG SERVED
SYSTEM
AND/OR
SERVICE
TYPE
CIRCULATING FLUID
PRESSURE
TRANSMITTER
SETPOINT
OUTLET BUFFER
TANK ACCEPTANCE
VOLUME
(MINIMUM)
ELECTRICAL MOTOR
FLUID NO
PUMPS
FLOW EA. PUMP HEAD EA. PUMP MIN
NPSH
AVAIL
TEMPERATURE
SP GR % EFF
NOMINAL POWER,
EA. PHASE VOLT MAX RPM SPEED
CONTROL REMARKS
GPM [L/s] FT [M] °F [°C] PSIG [kPa] GAL [L] HP [kW]
1-BP1
BLDG 1
BASEMENT
MECH ROOM BC
HOSPITAL
PRESSURE
FLOORS 3, 4,
AND 5
DOMESTIC
BOOSTER PUMP
VERTICAL
MULTISTAGE
DOMESTIC COLD
WATER 3 75 [ 5 ] 173.3 [ 52 ] N/A 50 [ 10 ] 1 68 75 [ 520 ] 30 [ 110 ] 3.0 [ 2 ] 3 208 3600 VARIABLE -----
NOTES:
1. UNIT INCOMING PRESSURE 50PSI, OUTLET PRESSURE TO BE 75 PSI. REFER TO SPECIFICATIONS FOR OPERATION.
2. PROVIDE UNIT WITH CAPABILITY TO INTERFACE WITH BAS. REFER TO DRAWINGS AND SPECIFICATIONS FOR MORE INFORMATION.
3. SYSTEM CONTROLLER SHALL ALTERNATE PUMPS TO EQUAL RUNTIME ON THE PUMPS. REFER TO SPECIFICATIONS FOR MORE INFORMATION.
4. PROVIDE SEPARATE PRESSURE SWITCHES FOR THE HIGH PRESSURE CUT OFF AND NOT FLOW CUT OFF SAFETIES. EACH DEVICE SHALL BE WIRED SEPARATELY TO THE BOOSTER PUMP CONTROL. THE USE OF A SINGLE DEVICE FOR VFD/SYSTEM PRESSURE CONTROL
AND MULTIPLE SAFETIES IS NOT ACCEPTABLE.
5. BASIS OF DESIGN UNIT ARMSTRONG DESIGN ENVELOPE 6800 BOOSTER SYSTEM MODEL N290102-3. CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES REQUIRED DUE TO DIFFERENCES FROM BASIS OF DESIGN MODEL INCLUDING COORDINATION WITH ELECTRICAL.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PL601
SCHEDULES - PLUMBING RENOVATE BUILDING 1
10/27/2023 SCOPRZ AARMEY 170 238Revisions: Date:
PROVIDE TWO 6" LOW PRESSURE DROP RPZ STYLE BACK FLOW
PREVENTORS ARRANGED IN PARALLEL CONFIGURATION ON 8" WATER LINE
SERVING BUILDING 1. UNITS SHALL BE INSTALLED ABOVE GRADE WITH
PIPING CONNECTION TO EXISTING MAINS LOCATED BELOW GRADE.
CONTRACTOR SHALL FIELD VERIFY EXISTING PIPING LOCATIONS PRIOR TO
EXCAVATING. CONTRACTOR SHALL COORDINATE TIE IN LOCATIONS AND
NEW BACKFLOW PREVENTOR LOCATION WITH THE RESIDENT ENGINEER.
CONNECT TO EXISTING 4" CW MAIN. ROUTE NEW 4" CW LINE THROUGH
BASEMENT WINDOW BOX AT BUILDING 53. CONTRACTOR SHALL VERIFY
EXISTING PIPE MATERIAL AT TIE-IN LOCATIONS. CONTRACTOR SHALL FIELD
VERIFY EXISTING PIPING LOCATIONS PRIOR TO EXCAVATING.
CONTRACTOR SHALL COORDINATE TIE IN LOCATION WITH THE RESIDENT
ENGINEER.
8" CW
8" CW
PRIMARY PUMP LOCATION
IN ROOM BC 109
ALTERNATE PUMP
LOCATION IN ROOM BC 109
APPROXIMATE LOCATION
OF ROOM BC 109
PROVIDE DOMESTIC WATER
BOOSTER PUMP SYSTEM IN
BASEMENT ROOM BC 109.
UNIT SHALL BE NO LARGER
THAN 72"W X 88" H X 60"D.
4" CW
CONTRACTOR TO TIE INTO VA FURNISHED 4"
COPPER PIPING WITH BACKFLOW PREVENTOR
IN MECHANICAL SPACE BELOW BUILDING 53.
REFER TO PL101 FOR MORE INFORMATION.
EXISTING 4" WATER
MAIN FOR BUILDING 53
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
520-317X
Dwg. of
PS101
SITE PLAN - PLUMBING RENOVATE BUILDING 1
BILOXI, MISSISSIPPI
10/27/2023 SCOPRZ AARMEY 136 238
KEYED NOTES:
1. CONNECT TO EXISTING LIFT STATION.
2. REFER TO PL101 FOR CONTINUATION.
GENERAL SHEET NOTES:
1. REFER TO PL601 FOR SYMBOLS AND NOTES.
2. CONTRACTORS SHALL REVIEW ROUTING OF PIPING
PRIOR TO BID. ROUTING SHOWN IS ONE POTENTIAL ROUTE
WITH FINAL ROUTE UP TO INSTALLING CONTRACTOR TO
DETERMINE.
3. CONTRACTORS SHALL COORDINATE ROUTING OF PIPING
WITH EXISTING CONDITIONS.
| Drawings - Plumbing - 2a |
| Drawings - Plumbing - 2b |
File details come from the government source that posted it. Updated .