P12_AE Addendum Two.pdf

PDF 2 MB Posted

Attached to
Biloxi Building 1 Renovation - Biloxi, MS -- Y1DA
Solicitation number
QSE--36C10F24R50025
Issued by

About this file

This document appears to be an addendum to the specifications for the Biloxi Building 1 Renovation project. The addendum provides updates to Section 02 82 13.19 - Tile and Mastic and Brick Coating Abatement, and Section 02 83 33.13 - Lead Paint Removal. It also includes revisions to drawings FA101 - 3rd Floor Fire Alarm, FA102 - 4th Floor Fire Alarm, and FA201 - Legends and Riser. The key changes are the removal of local operation console devices from certain rooms, and the addition of a notation that devices compatible with the existing fire alarm system will be VA provided and contractor installed.

The overall federal contract opportunity is for the full renovation of Biloxi Building 1, including selective demolition, exterior envelope alterations, interior renovations, and upgrades to HVAC, plumbing, electrical, telecommunications, and fire protection systems. The project magnitude is between $50M to $100M, with a period of performance of 912 calendar days. Wage Rate Requirements (Construction) apply.

View the file

Other files

File Type Posted
S02_Solicitation Amendment 0003.pdf PDF
C28_02821319 TILE AND MASTIC AND BRICK COATING ABATEMENT.pdf PDF
C28_02833313 LEAD PAINT REMOVAL.pdf PDF
SolicitationAmendment0004.pdf PDF
P03_Justification and Approval - TekTone Nurse Call System - revised 05.24.24.pdf PDF
P12_Asbestos Report - 01.03.2022.pdf PDF
SolicitationAmendment0003.pdf PDF
52.219-28 Post-Award Small Business Program Rerepresentation.pdf PDF
Wage Determination - Harrison County MS.pdf PDF
QSE 36C10F24R50025.pdf PDF
P12_Asbestos Report - 07.06.2017.pdf PDF
S05_RFI Questions and Answers.pdf PDF
P12_Lead Based Paint Analysis - Bldg 1 - 01.11.2017.pdf PDF
S02_117300 CEILING MOUNTED PATIENT LIFTS - Revised.pdf PDF
P12_Asbestos Report - 05.06.2008.pdf PDF
P12_Addendum 1 - 05.14.2024.pdf PDF
S04_Biloxi Bldg 1 Reno - Pre-Proposal Conference Attendees.pdf PDF
SolicitationAmendment0002.pdf PDF
SolicitationAmendment0001.pdf PDF
QSE 36C10F24R50025.pdf PDF
Wage Determination - Harrison County MS.pdf PDF
52.219-28 Post-Award Small Business Program Rerepresentation.pdf PDF
Drawings - Architectural - 3.pdf PDF
General Contractor Reference Form.docx DOCX document
Drawings - Telecommunication.pdf PDF
Drawings - Architectural - 4.pdf PDF
Drawings - Reference.pdf PDF
VA Biloxi 4th Floor Footwall.pdf PDF
Drawings - Architectural - 1.pdf PDF
Building 1 Inventory - d.pdf PDF
Adec Submittal - VA Biloxi.pdf PDF
Drawings - Electrical - 2.pdf PDF
LOCQ7780-03-SWS-Biloxi VA Dental Lab.pdf PDF
Justification and Approval - Siemens Security and Video Surveillance System.pdf PDF
Past Performance Questionnaire.docx DOCX document
A-dec Floor Plan - VA Biloxi - Elevations.pdf PDF
Drawings - Structural - 2.pdf PDF
Specifications Volume II.pdf PDF
Biloxi VA Reno B1 - Set H.pdf PDF
Drawings - Plumbing - 1.pdf PDF
Drawings - Structural - 1.pdf PDF
VA Biloxi Patient Room Footwall Typical Elevation.pdf PDF
Justification and Approval - Herman Miller Compass Patient Care Modular System.pdf PDF
Solicitation.pdf PDF
000000 Cover Page Appendix.pdf PDF
Justification and Approval - ESTIII Fire Alarm System.pdf PDF
Drawings - General.pdf PDF
A-dec Floor Plan - VA Biloxi - Preliminary.pdf PDF
Drawings - Mechanical - 2.pdf PDF
Drawings - Plumbing - 2.pdf PDF
Show 40 more

Latest 50 of 64 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM #2

SPECIFICATION SECTIONS

1. Section 02 82 13.19 Tile and Mastic and Brick Coating Abatement is issued with this Addendum.

2. Section 02 83 33.13 Lead Paint Removal is issued with this Addendum.

DRAWINGS

1. Drawing FA101 – THIRD FLOOR – FIRE ALARM:

a. REMOVE local operation console device from C3-105.

2. Drawing FA102 – FOURTH FLOOR – FIRE ALARM:

a. REMOVE local operation console device from C4-105.

3. Drawing FA201 – LEGENDS AND RISER – FIRE ALARM

a. ADD notation that devices compatible with the existing fire alarm system will be VA provided and contractor installed.

END OF ADDENDUM #2

SJW

Enclosures: 02 82 13.19, 02 83 33.13, FA101, FA102, FA201

VA Biloxi

ANDERSON #15090

IMEG #17002162.02 Addendum #2 Page 1 of 1

D

D

D

L

F

L

L

L

L

L

L

F

FAPU

FS

D S

D D

S D

C C

FS

DH

DH

F

L L

L

F

L

LL

L

FLTSLFLTSM M

D

L

L

L

FS

FAA

L

L

L

FS

D

MM

FS

FSFS

D

DH

DH

D D

FS

FS FS

FS

FS

FS

FS FS FS FS

FS

FS

FS

FS

FS

L

L

L

L

L

L

FS

FS

FS FS

L

L

L

FS

FS

FS

FS

FS

FS

L

L

L

L

L

L

L

L

FS

L

L

FS

L

L

C D

S D

C

DSD

L

DSD

DSD

DSD

C

C

C

D

FAA

PATIENT ROOM 1

3B114

PATIENT ROOM 2

3B116

PATIENT ROOM 3

3B118

PATIENT ROOM 4

3B119

CLEAN EQUIPMENT STORAGE

3B121

MD DICTATION

3B122

PATIENT ROOM 5

3B123 PATIENT ROOM 6

3B124

WHEELCHAIR ALCOVE

3B102

ELECTRICAL ROOM

3B101

PATIENT CENTERED CARE

3B103

MEDICAL GAS STORAGE

3B104

CRASH CART

3B105

HAC

3B106

CLEAN UTILITY

3B107

CLEAN LINEN

3B108

KINESIOTHERAPY

3B109

WEST STAIR

3B110

PATIENT ROOM 7 - NEGATIVE

PRESSURE

3B111

UNASSIGNED

3B113

PATIENT BATHROOM

3B111A

ANTE ROOM

3B111B

PATIENT BATHROOM

3B114A

PATIENT BATHROOM

3B118A

PATIENT BATHROOM

3B119A

PATIENT BATHROOM

3B123A

PATIENT BATHROOM

3B124A

CORRIDOR

C3-104

CENTRAL STAIR

3A101

MALE TOILET

3A102

FEMALE TOILET

3A103

FAMILY TOILET

3A104

WAITING / LOUNGE

3A105FAMILY CONSULTATION

3A106

MECHANICAL SHAFT

3A107

SOILED LINEN

3A110

ENGINEERING

3A111

HEAD NURSE / ASSISTANT MANAGER

3A112

MEDICATION ROOM

3A114

NOURISHMENT STATION

3A115

PATIENT ROOM 8

3A117

PATIENT ROOM 9

3A118

MD DICTATION

3A120

IMD SUPPLY STORAGE

3A121

PATIENT ROOM 10

3A122

PATIENT ROOM 11

3A123

BARIATRIC PATIENT ROOM 12

3A125

CONFERENCE / REPORT ROOM

3A128

PATIENT BATHROOM

3A117A PATIENT BATHROOM

3A118A

PATIENT BATHROOM

3A122A PATIENT BATHROOM

3A123A

BARIATRIC PATIENT BATHROOM

3A125A

HAC

3A127

TELEMETRY

3A130

BARIATRIC PATIENT BATHROOM

3A131A

BARIATRIC PATIENT ROOM 13 - NEG.

PRESS.

3A131

ANTE ROOM

3A131B

EAST STAIR

3A133

PHARMACY CUBICLES

3A134

MALE LOCKERS

3A137

STAFF TOILET

3A136

STAFF SHOWER

3A135

CORRIDOR

3A141

STAFF LOUNGE

3A138

FEMALE LOCKERS

3A139

TELECOMM

3A140

SOILED UTILITY

3A142

NURSE STATION

3A109A

CORRIDOR

C3-105

CORRIDOR

C3-103

NURSE SERVER

3A124

CORRIDOR

C3-109

NURSE SERVER

3A132

CORRIDOR

C3-101

NURSE SERVER

3B112

NURSE SERVER

3B125

CORRIDOR

C3-107

NURSE SERVER

3A126NURSE SERVER

3A119

NURSE SERVER

3B120NURSE SERVER

3B117

NURSE SERVER

3B115

NURSE STATION

3A109

PATIENT BATHROOM

3B116A

CORRIDOR

C3-100

CORRIDOR

C3-102

CORRIDOR

C3-102A

CORRIDOR

C3-106

CORRIDOR

C3-107A

CORRIDOR

C3-108

L

(15)(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)(15)

(15)

222019181716151413121110987654321 21

A

B

C

D

E

F

G

(15)

BPS

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)(15)

(15)

(15)

(15)

(15)

(15) (15)

(15)

(15) (15)

(15)

(15)

(15)

CENTRAL STAIR

1A101

13121110

A

B

C

D

RM 1A100

FACP

13121110

G

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of

C R e v it L o c a l F ile s \I C

T

B L

D G

E le c tr ic a l C

D S

S te v e n .J

.W ie g e rs .r v t

/2

/2

:0

:1

P

M

FA101

3RD FLOOR - FIRE ALARM RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 IMEG STEWIE

218 238

1/8" = 1'-0"FA101

1 3RD FLOOR - FIRE ALARM

1/8" = 1'-0"FA101

2 LEVEL 1 PARTIAL PLAN - FIRE ALARM

1/8" = 1'-0"FA101

EXISTING 1ST FLOOR PARTIAL PLAN - FIRE ALARM -

FAA LOCATION

GENERAL NOTES:

1. REFER TO SHEET E001 FOR ELECTRICAL SYMBOLS,

GENERAL NOTES, RENOVATION NOTES, AND

INSTALLATION NOTES.

DEDUCT ALTERNATE:

1. REFER TO GENERAL CONDITIONS SPECIFICATIONS

FOR REQUIREMENTS OF DEDUCT ALTERNATE.

Revisions: Date:

ADDENDUM #2 5/24/2024

D D

D

L

F

L

L

L

L

F

FAPU

FS

D S

D D

S D

D S

D C

C C

FS

DH

DH

F

L L

L

F

L

L

LL

L

FLTSL

FLTS

M M

D

L

L

L

FS

FAA

L

L

L

D

MM

FS

FSFS

L

L

FS

L

L

DH

DH

D D

L

D

FS

FS FS

FS

FS FS FS FS

FS FS

FS

FS

L

L

L

L

FS

L

D

D

FS

L

FS

FS

L

FS

L

L

FS

L

L

L

L

L

FS

FS

L

L

FS

L

FS

FS

FS

FS

CDSD

C

DSD

CDSD

CDSD

DSD

DSD

DSD

DSD

C

C

C

C

PATIENT ROOM 1

4B114

PATIENT ROOM 2

4B116

PATIENT BATHROOM

4B116A

PATIENT BATHROOM

4B114A

PATIENT BATHROOM

4B118A

PATIENT BATHROOM

4B119A

PATIENT ROOM 3

4B118

PATIENT ROOM 4

4B119

CLEAN EQUIPMENT STORAGE

4B121

MD DICTATION

4B122

PATIENT ROOM 5

4B123

PATIENT BATHROOM

4B123A

PATIENT BATHROOM

4B124A

PATIENT ROOM 6

4B124 ENGINEERING

4A111

SOILED LINEN

4A110

STAFF EDUCATION

4A112

MEDICATION ROOM

4A114

NOURISHMENT STATION

4A115

PATIENT ROOM 8

4A117

PATIENT BATHROOM

4A117A

PATIENT BATHROOM

4A118A

PATIENT ROOM 9

4A118

IMD SUPPLY STORAGE

4A121

MD DICTATION

4A120

PATIENT ROOM 10

4A122

PATIENT BATHROOM

4A122A

PATIENT BATHROOM

4A123A

PATIENT ROOM 11

4A123

BARIATRIC PATIENT ROOM 12

4A125

BARIATRIC PATIENT BATHROOM

4A125A

CONFERENCE / REPORT ROOM

4A128

BED STORAGE

4A130BARIATRIC PATIENT BATHROOM

4A131A

BARIATRIC PATIENT ROOM 13 - NEG.

PRESS.

4A131

M.O.D. ROOM

4A134

EAST STAIR

4A133

STAFF TOILET

4A136

STAFF SHOWER

4A135

MALE LOCKERS

4A137

STAFF LOUNGE

4A138

FEMALE LOCKERS

4A139

TELECOMM

4A140

SOILED UTILITY

4A142

CORRIDOR

4A141

ANTE ROOM

4A131B

CENTRAL STAIR

4A101

MALE TOILET

4A102

FEMALE TOILET

4A103

FAMILY TOILET

4A104

FAMILY CONSULTATION

4A106

MECHANICAL SHAFT

4A107

CORRIDOR

C4-104

WAITING / LOUNGE

4A105

ELECTRICAL ROOM

4B101

PATIENT CENTERED CARE

4B103

MEDICAL GAS STORAGE

4B104

CRASH CART

4B105

HAC

4B106

CLEAN UTILITY

4B107

CLEAN LINEN

4B108

KINESIOTHERAPY

4B109

WHEELCHAIR ALCOVE

4B102

WEST STAIR

4B110

PATIENT ROOM 7 - NEGATIVE

PRESSURE

4B111

PATIENT BATHROOM

4B111A

UNASSIGNED

4B113

ANTE ROOM

4B111B

CORRIDOR

C4-103

NURSE STATION

4A109A

CORRIDOR

C4-105

CORRIDOR

C4-101

CORRIDOR

C4-107

NURSE SERVER

4B120

NURSE SERVER

4B125

NURSE SERVER

4A119

NURSE SERVER

4A124

NURSE SERVER

4A132

NURSE SERVER

4B112

HAC

4A127

NURSE SERVER

4B115

NURSE SERVER

4B117

NURSE SERVER

4A126

M.O.D. BATHROOM

4A134A

CORRIDOR

C4-109

NURSE STATION

4A109

DENTAL VAC CLOSET

4B100A

SIM

TYP

FEC

FEC FEC

NOTE: SEE SHEET "IN102" FOR INTERIOR ELEVATION REFERENCE

CORRIDOR

C4-100

CORRIDOR

C4-102

CORRIDOR

C4-102A

CORRIDOR

C4-106

CORRIDOR

C4-107A

CORRIDOR

C4-108

222019181716151413121110987654321 21

A

B

C

D

E

F

G

L

(15)(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

BPS

(15)

(15)

(15)

(15)

(15)

(30)

(30)

(30) (30)

(15)

(15)

(15)

(15)

(15)

(15)

SYSTEM

CONNECTED,

SOUNDER BASE

(15)

(15)

(15)

(15) (15)

(15) (15)

(15)

(15)

(15)

(15) (15)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of

C R e v it L o c a l F ile s \I C

T

B L

D G

E le c tr ic a l C

D S

S te v e n .J

.W ie g e rs .r v t

/2

/2

:0

:1

P

M

FA102

4TH FLOOR - FIRE ALARM RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 IMEG STEWIE

219 238

1/8" = 1'-0"FA102

1 4TH FLOOR - FIRE ALARM

GENERAL NOTES:

1. REFER TO SHEET E001 FOR ELECTRICAL SYMBOLS,

GENERAL NOTES, RENOVATION NOTES, AND

INSTALLATION NOTES.

FIRE ALARM SYSTEM NOTES

• The location of the branch circuit disconnecting means shall be identified at all fire alarm control equipment.

• Disconnecting means for fire alarm system components shall be identified with a red marking.

• A duct smoke detector shall be provided within five feet of all fire smoke dampers and located per the requirements of the International Building Code.

• Duct smoke detectors shall be provided in all HVAC units greater than 2000 CFM per the International Building Code.

• Contractor shall refer to the mechanical drawings for drawings and details associated with the shutdown of HVAC equipment.

• HVAC units serving egress corridors shall shutdown automatically upon activation of the fire alarm system.

• A connection to the fire pump controller shall be provided for supervision.

• Contractor shall provide fire alarm connections to all kitchen hoods as required by the hood assembly. All electrical equipment located under the hood shall be shunt trip at the breaker in the panel serving the equipment via the fire alarm system.

• Heat detectors shall be provided with in 24” of each sprinkler located within the elevator hoistways, elevator pits, elevator machine rooms and elevator control rooms for shut down of elevator prior to sprinkler operation. Contractor shall coordinate with sprinkler layout and shop drawings for quantity of heat detectors to be provided. Contractor shall provide the shunt trip breaker(s) in the panel which serves the elevator equipment. The shunt trip operation shall not occur within the elevator machine/control room.

• All electrically locked doors in a required means of egress shall automatically release upon activation of the fire alarm system. Coordinate locations with architectural floor plans and door schedules.

• Emergency communication system circuits shall meet the survivability requirements as indicated in NFPA 72.

• Level 2 or Level 3 pathway survivability is required for in building emergency communications systems employing relocation or partial evacuation.

• Where two-way emergency communications systems are required/specified, fireman’s telephone jacks shall be provided at all locations as indicated in NFPA 72.

• Level 2 or Level 3 pathway survivability is required for two-way in building wired emergency communications systems.

• Level 2 or Level 3 pathway survivability is required for area of refuge wired emergency communications systems.

• A weather-proof fire alarm horn/strobe shall be provided outside of the fire sprinkler room.

• Fire alarm contractor shall provide connection to the overhead paging or voice reinforcement system as required for automatic override of those systems in the event of a fire. Coordinate with appropriate vendor for exact integration requirements.

No Scale

NOTES FOR FIRE ALARM SYSTEM

2. SMOKE DETECTOR IS AN ADDRESSED ZONE ONLY.

NOTES:

5. SOLENOID VALVE KEEPS WATER OUT OF SHAFT AND MACHINE ROOM.

3. LOBBY SMOKE DETECTOR IS ADDRESSED SPECIFICALLY BY ZONE AND INITIATES

ELEVATOR RECALL DIRECTLY (NOT THRU F.A.C.P.).

1. HEAT DETECTOR IN MACHINE ROOM OR SHAFT OR PIT (LESS THAN 2' FROM BOTTOM)

EITHER DIRECTLY OR THRU THE F.A.C.P. UPON DETECTION OF HEAT (135 F):

4. FLOW SWITCH IS A SPECIFIC ADDRESS AND INDICATES AN OPEN SPRINKLER HEAD

IN SHAFT OR MACHINE ROOM.

6. THIS SMOKE DETECTOR IS AN ADDRESSED ZONE AND LIGHTS AN L.E.D. MOUNTED

AT THE FIRE FIGHTERS OPERATION KEY SWITCH TO ALERT FIRE DEPT. PERSONEL OF

SMOKE IN ELEV. SHAFT.

SMOKE DETECTOR

HEAT DETECTOR

SOLENOID VALVE

FLOW SWITCH

TAMPER SWITCH

SPRINKLER HEAD

SD

HD

SV

FS

TS

FIRE ALARM CONTROL PANELFACP

LEGEND

SD

NOTE 1

SD

NOTE 3

SDHD SVFLTS

ELEVATOR

MACHINE

ROOM

NOTE 1

NOTE 6

NOTE 5

NOTE 4

NOTE 1

NOTE 2

A. OPENS ITS ASSOCIATED SOLENOID VALVE

B. KILLS POWER TO ELEVATOR WITH A SHUNT TRIP BREAKER.

C. IS ADDRESSED SPECIFICALLY AT THE F.A.C.P.

D. LOCATE HEAT DETECTOR WITHIN 18" FROM EACH SPRINKLER HEAD.

ALL DETECTION ASSOCIATED WITH ELEVATOR RECALL AND ELEVATOR

SHUTDOWNSHALL BE CONNECTED AND SUPERVISED THROUGH THE BUILDING FIRE

ALARM SYSTEMIN ACCORDANCE WITH NFPA 72, 3-9.3.1. CONTROL CIRCUITS TO SHUT

DOWNELEVATOR POWER SHALL BE MONITORED IN ACCORDANCE WITH NFPA 72, 3-9.4.4.

GENERAL NOTE:

No Scale

ELEVATOR FIRE ALARM SYSTEM

HD

HD

SD

NOTE 3

SD

NOTE 3

SD

NOTE 3

CAB

SD

NOTE 3

SD

NOTE 3

FIRST FLOOR

FACP

NEW

REMOTE

ANNUNCIA

TOR IN

LOBBY.

3. REFER TO MECHANICAL FOR ADDITIONAL NOTES ON SEQUENCE OF OPERATION FOR THE

SHUT DOWN OF AIR HANDLING UNITS.

GENERAL NOTES:

4. ALL MAGNETIC DOOR HOLD OPEN DEVICES ARE TO RELEASE UPON ALARM ACTIVATION.

5. ALL ACCESS CONTROL DEVICES ARE TO "UNLOCK" UPON ALARM.

(TYPICAL INSTALLATION REPRESENTED)

FIRE ALARM RISER DIAGRAM

2. FIRE ALARM SHUTDOWN

A. WHENEVER THE FIRE ALARM SYSTEM SENSES SMOKE/FIRE, THE FIRE

ALARMSYSTEM SHALL SIGNAL THE DDC SYSTEM.

B. THE DDC SYSTEM IS TO DE-ENERGIZE THE UNIT AND SHALL PERFORM

THEFOLLOWING.

1) SHUTDOWN THE SUPPLY AIR FAN

2) SHUTDOWN THE RETURN AIR FAN

3) SHUTDOWN THE ASSOCIATED EXHAUST FANS.

4) CLOSE CHILLED WATER VALVE V-CHW.

5) CLOSE THE OUTSIDE AIR DAMPER (D-OSA).

6) OPEN THE RETURN AIR DAMPER (D-RET).

NOTES:

2. PROVIDE BUILDING MAP AT THE FACP LOCATIONS AND ANNUNCIATOR THAT INDICATES

ZONES AND DEVICES. THE MAP SHALL BE ENGRAVED PHENOLIC WITH 1/4" HIGH HIGH LETTERING, SIZED AS REQUIRED.

3. PROVIDE WEATHERPROOF DEVICES WERE SHOWN OR AS REQUIRED BASED ON THE

LOCATION OF THE DEVICE.

4. RECORD AND SHOP DRAWINGS SHALL INDICATE EXACT ROUTING AND LOCATIONS OF ALL

DEVICES, CONDUITS (TYPES AND SIZES), CONDUCTORS (TYPES AND SIZES) AND ALL PERTINENT

INSTALLATION INFORMATION.

5. USE FINAL ACTUAL ROOMS NAMES AND NUMBERS BASED IN THE INSTALLATION OF

SIGNAGEAND NOT THE ARCHITECTURAL ROOM NAMES WHEN PROGRAMMING THE FINAL

SYSTEM.

1. APPROVED FIRE ALARM SHOP DRAWINGS TO BE SUBMITTED TO THE AUTHORITY

HAVING JURISDICTION.

No Scale

FIRE ALARM RISER DIAGRAM

TYPICAL THIRD THRU 5TH FLOOR

(COMPLY WITH

NFPA 72- 8.5.3.2)

D D

R

L L

D

L

BPS

D D

L

D

LL

PHONE LINES

DEDICATED

REMOTE

ANNUNCIATOR

PANEL

J

(VERIFY QUANTITIES

AND LOCATIONS, ADD

AS REQUIRED)

(VERIFY QUANTITIES

AND LOCATIONS)

TSFL

FIRE ALARM TAMPER

& FLOW SWITCHES FOR THE

BACK FLOW PREVENTER.

COORDINATE THE FINAL

LOCATIONS AND QUANTITIES.

F

INDICATING

DEVICES

INITIATING

DEVICES

INDICATING

DEVICES

INITIATING

DEVICES

CONTROL

DEVICES

ATTIC FLOOR

BPS

J

JUST OUTSIDE

RM 1A100

No Scale

FIRE ALARM RISER DIAGRAM NOTES

D D

R

L L

D

L

D D

L

D

LL

F

INDICATING

DEVICES

INITIATING

DEVICES

INDICATING

DEVICES

INITIATING

DEVICES

CONTROL

DEVICES

REMOTE

ANNUNCIATOR

PANEL

EXTEND EXISTING EDWARDS

FIRE ALARM SYSTEM

1. FIRE ALARM DEVICES REQUIRED TO BE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM WILL BE VC (VA PROVIDED/CONTRACTOR INSTALLED). ALL WIRING FOR THE FIRE ALARM SYSTEM WILL BE CC (CONTRACTOR

PROVIDED/CONTRACTOR INSTALLED).

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of

C R e v it L o c a l F ile s \I C

T

B L

D G

E le c tr ic a l C

D S

S te v e n .J

.W ie g e rs .r v t

/2

/2

:4

:4

A

M

FA201

LEGENDS AND RISER - FIRE ALARM RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 IMEG STEWIE

222 238

(95)

DH

PS

FS

FL

TS

E

S

DSD

D

SD

SD

HD

L

D

SYSTEM CONNECTED SMOKE DETECTOR FOR FIREMAN'S RECALL

DUCT-SMOKE DETECTOR INDICATOR LIGHT (WALL MOUNTED 10"BELOW CEILING)

HORN/FLASHING LIGHT COMBINATION (CANDELA VALUE AS SPECIFIED)

SMOKE DOOR HOLDER

FIRE SPEAKER CEILING MOUNTED

TAMPER SWITCH

PRESSURE SWITCH

FLOW SWITCH

SYSTEM CONNECTED SMOKE DETECTOR

SYSTEM CONNECTED SMOKE DETECTOR

AUTOMATIC HEAT DETECTOR (RATE OF RISE TYPE)

DUCT-SMOKE DETECTOR (SUPPLY) OR (RETURN)

BELL/FLASHING LIGHT COMBINATION

CHIME/FLASHING LIGHT COMBINATION

MANUAL PULL STATION

6'-0"

CEILING

CEILING

CEILING

80"

46"

80"

80"

NON-SYSTEM CONNECTED SMOKE DETECTOR. CONNECT TO 120V.(WITH BATTERY BACK UP.)

CEILING

WALL @ 7'

L

L

L

F

B

VCP

M

FAA

FAPU

FAST

FACC

FR

E.O.L.

C

FAPC

FACP

SV

SA

GRA

HI

GV

FIRE ALARM MONITOR MODULE, ADDRESSABLE

FIRE ALARM CONTROL MODULE, ADDRESSABLE

SPEAKER STATION WALL MOUNTED SPEAKERS TO BE DUAL CONE, LTS TO BE DUAL WHITE/AMBER

VOICE CONTROL PANEL

END OF LINE DEVICE

COMMAND CENTER

CENTRAL PROCESSING UNIT

REMOTE ANNUNCIATOR

CONTROL PANEL

TRANSPONDER

FIRESTAT

PULL CABINET

7'-0"

SOLENOID VALVE

SMOKE DETECTOR W AUDIBLE ALARM.

GENERATOR ANNUNCIATOR PANEL

LED TEXT DISPLAY FOR HEARING IMPAIRED

GAS VALVE SHUT OFF

FLASHING LIGHT SPEAKER SIGNAL STATION WALL MOUNTEDL

S

FS FLASHING LIGHT FIRE SPEAKER CEILING MOUNTEDL

FLASHING LIGHT 80"LL

FIRE ALARM SYSTEM

FLASHING LIGHT CEILING MOUNTEDL

LOC LOCAL OPERATING CONSOLE

7'-0"

BPS FIRE ALARM BOOSTER POWER SUPPLY

P12_20240524_Addendum #2_Narrative
C28_Electrical Addendum #2
Sheets
FA101 - 3RD FLOOR - FIRE ALARM
FA102 - 4TH FLOOR - FIRE ALARM

File details come from the government source that posted it. Updated .