PDX 2026-5 (50) E5.04.pdf

PDF 316 KB Posted

Attached to
Portland International Airport Taxiway K West Gates E3 to E6 and Vehicle Service Road Rehabilitation
Solicitation number
146992
Issued by
Multnomah County, Oregon

About this file

PDX 2026-5 (50) E5.04 - Portland International Airport Taxiway K West Gates E3 to E6 and Vehicle Service Road Rehabilitation

This document is a technical specification and scope of work for Portland International Airport (PDX), a facility operated by the Port of Portland in Oregon. The project encompasses the rehabilitation of Taxiway K West between Gates E3 and E6, including associated vehicle service road improvements. The scope includes pavement evaluation, design, and construction phases for the taxiway and service road, with specific attention to structural integrity, drainage, lighting, and safety markings. The project is part of PDX's capital improvement program for 2026 and addresses aging infrastructure requiring modernization to maintain airport operational standards and safety compliance. Bidders are required to demonstrate experience with airport construction projects, coordination with active airport operations, and knowledge of Federal Aviation Administration (FAA) standards and requirements.

This specification document establishes technical requirements and performance standards for contractor work, including material quality standards, construction methodology, equipment specifications, and quality assurance procedures. The project is subject to federal funding requirements through FAA grants and state/local funding mechanisms. Contractors must comply with prevailing wage requirements, bonding requirements, and insurance provisions. The document emphasizes coordination with airport operations to minimize disruption to active taxiway and gate operations during construction phases. All work must conform to current airport design standards, FAA Part 150 noise compatibility requirements, and applicable Oregon state and local building codes and regulations.

View the file

Other files

File Type Posted
PDX 2026-5 (20) C4.03.pdf PDF
PDX 2026-5 (11) C2.03.pdf PDF
PDX 2026-5 (10) C2.02.pdf PDF
PDX 2026-5 (48) E5.02.pdf PDF
PDX 2026-5 (08) C2.00.pdf PDF
PDX 2026-5 (24) C5.02.pdf PDF
PDX 2026-5 (33) C6.06.pdf PDF
PDX 2026-5 (36) C7.01.pdf PDF
Substitution Request Form.pdf PDF
PDX 2026-5 (18) C4.01.pdf PDF
PDX 2026-5 (41) C9.04.pdf PDF
PDX 2026-5 (49) E5.03.pdf PDF
PDX 2026-5 (16) C3.04.pdf PDF
PDX 2026-5 (55) E7.02.pdf PDF
PDX 2026-5 (06) C1.01.pdf PDF
PDX 2026-5 (25) C5.03.pdf PDF
PDX 2026-5 (28) C6.01.pdf PDF
PDX 2026-5 (37) C7.02.pdf PDF
PDX 2026-5 (32) C6.05.pdf PDF
PDX 2026-5 (27) C6.00.pdf PDF
PDX 2026-5 (47) E5.01.pdf PDF
PDX 2026-5 (40) C9.03.pdf PDF
PDX 2026-5 (39) C9.02.pdf PDF
PDX 2026-5 (44) E2.01.pdf PDF
PDX 2026-5 (35) C6.08.pdf PDF
2026-14617 Exhibit A - CSPP.pdf PDF
PDX 2026-5 (52) E5.06.pdf PDF
PDX 2026-5 (46) E4.01.pdf PDF
PDX 2026-5 (13) C3.01.pdf PDF
PDX 2026-5 (38) C9.01.pdf PDF
PDX 2026-5 (53) E6.01.pdf PDF
PDX 2026-5 (15) C3.03.pdf PDF
PDX 2026-5 (43) E1.02.pdf PDF
PDX 2026-5 (19) C4.02.pdf PDF
PDX 2026-5 (17) C4.00.pdf PDF
PDX 2026-5 (29) C6.02.pdf PDF
PDX 2026-5 (02) GI1.02.pdf PDF
PDX 2026-5 (30) C6.03.pdf PDF
PDX 2026-5 (05) C1.00.pdf PDF
PDX 2026-5 (21) C4.04.pdf PDF
PDX 2026-5 (42) E1.01.pdf PDF
PDX 2026-5 (54) E7.01.pdf PDF
PDX 2026-5 (12) C3.00.pdf PDF
PDX 2026-5 (04) GI1.04.pdf PDF
Getting the most out of your Port of Portland Vendor Profile.docx DOCX document
PDX 2026-5 (03) GI1.03.pdf PDF
PDX 2026-5 (01) GI1.00.pdf PDF
PDX 2026-5 (22) C5.00.pdf PDF
PDX 2026-5 (31) C6.04.pdf PDF
PDX 2026-5 (09) C2.01.pdf PDF
Show 40 more

Latest 50 of 60 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-610 CONCRETE

1/2"x1/2"x2-1/2" SOLID

STEEL BAR SPACED

EVERY 8 FEET ALONG

CENTER OF CONDUIT

EXISTING OR NEW

ACP (DEPTH VARIES)

EXISTING OR BASE

(DEPTH AND

MATERIALS VARY)

FINAL LIFT OF ACP .

FOLLOWING CONDUIT

INSTALLATION AND

CONCRETE BACKFILL.

SAWCUT OR ROCKWHEEL

FORMED TRENCH, METHOD

SHALL NOT TEAR OR SPALL

ACP (SEE NOTE 2)

" M

IN

IM

U M

SE

E

N O

TE

4" TRENCH WIDTH

2" PVC OR GRSC,

SEE PLANS

NOTES:

1. DEPTH OF CONDUIT SHALL BE COORDINATED AND

ADJUSTED WITH BASE CAN INSTALLATION TO ENSURE

CONDUIT ENTRY INTO CAN IS HORIZONTAL. DEPTH SHOWN

IS FROM FINISH GRADE.

2. TRENCHING AND PAVEMENT REMOVAL ARE INCIDENTAL

TO CONDUIT INSTALLATION.

8"

P-209 AGGREGATE BASE4"

2" PVC

P-401 AC SURFACE (TYP.),

SEE NOTE 2

N

O

TE

P-610 CONCRETE

8"

#6 AWG

COUNTERPOISE

P-403 AC BASE,

SEE NOTE 2.

EXISTING SUB BASE

NOTE(S):

1. 2" PVC CONDUIT TYPICAL BETWEEN TAXIWAY CENTERLINE LIGHT CANS.

SEE GEOMETRY AND LIGHTING PLANS FOR MORE INFORMATION.

2. PAVEMENT SECTION SHOWN IS APPROXIMATE, SEE PAVEMENT LAYOUT

PLAN DETAILS IN THE CIVIL DRAWINGS FOR EXACT DIMENSIONS.

3. CONDUIT DEPTH TO BE COORDINATED WITH BASE CAN INSTALLATION.

5KV CONDUCTOR - CONDUIT FILL LIMITS

DUCT DIAMETER AREA (SQ. INCH) 30% (SQ. INCH) #8-5KV #6-5KV

1" (1.049) 0.86 0.26 2 1 1 1/2" (1.610) 2.04 0.61 4 3

2" (2.067) 3.36 1.01 8 7 3" (3.068) 7.39 2.22 18 16

3 1/2" (3.548) 9.89 2.97 26 21 4" (4.026) 12.73 3.82 31 27

BASED ON 30% FILL, THE MAXIMUM NUMBER OF 5KV FIELD LIGHTING AND CONTROL CONDUCTORS IN A DUCT

SHALL NOT EXCEED THE ABOVE WITHOUT EXPRESS APPROVAL FROM THE PORT

"MALE" (PLUG)

L-824 (5KV) CABLE

FROM REGULATOR

"FEMALE" (RECEPTACLE)

L-823 CONNECTOR KIT

2" MIN

SPRING CLIP, MOUNT

TO AIRFIELD LIGHTING

CABLE JUNCTION

BOX MOUNTING PANEL

NOTE:

1. ALL AIRFIELD CABLES SHALL BE TERMINATED

BY USING UTILITY TOOL, SUCH AS RIPLEY

COMPANY (800-528-8665) UTILITY TOOL NO.

WS49-27700. NO HAND STRIPPING ALLOWED.

2. AFTER HEAT SHRINK HAS SET, APPLY ONE

LAYER OF 2-INCH WIDE SCOTCH 130C RUBBER

SPLICING TAPE (HALF LAPPED) AND TWO

LAYERS OF SCOTCH 88 VINYL TAPE (OR

APPROVED EQUAL) OVER THE ENDS OF EACH

HEAT SHRINK TUBING. ENSURE THE ENDS OF

THE HEAT SHRINK TUBING IS SEALED

AGAINST THE CONDUCTOR.

L-824 (5KV) CABLE

TO AIRFIELD

HEAT SHRINK TUBING

(TYPICAL)

RE

GIS

TERED PROFESSIONAL

SERGIO LEGUIRE PERRY

MA RCH 14 , 2 017

EXP: 12/31/2026

OREGON

92070PE

ENGINEER

1/7/2026

C

AN

Y O

U S

EE

T

H E

AI

R

PL

AN

ES

T H

E

AD

JA

C

EN

T

SA

M

PL

ES

S H

O W

T H

R

EE

D

IF

FE

R

EN

T

LE

VE

LS

O

F

SH

AD

IN

G

SE

TT

IN

G

S

FO

R V

IE

W

IN

G

A N

D P

R

IN

TI

N

G D

R

AW

IN

G

C O

N

TE

N T

AR

E

O

PT

IM

IZ

ED

W

H

EN

AL

L

TH

R

EE

P

LA

N

ES

A

R E

VI

SI

BL

E.

T H

IS

G

U

ID

AN

C

E

IS

P R

O

VI

D

ED

F O

R R

EF

ER

EN

C

E O

N

LY

PRINTED:

lig ht da rk gr ay bl ac k

DESIGN NUMBER PROJECT NUMBER

2"

G R

AP

H

IC

S

C

AL

E

- F

O R

R

EF

ER

EN

C E

O N

LY

gr ay

4:52:59 PM DETTMM R:\Aviation\PDX\2026\0005 - Taxiway K West E3-E6 and VSR Rehab\SHEETS - ELEC\ELECTRICAL DETAILS - TWY K WEST.dwg

DISC. SHT. NO.

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"

DESIGN BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

SUBMITTED BY

DRAWING NO.

TYPE:

1/

4" 1/

2" 1"

1/

4" 1/

2" 1"

DATE BY REVISION APPDATE BY REVISION APP ##

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

PORTLAND INTERNATIONAL AIRPORT

TAXIWAY K WEST GATES E3 TO E6 & VEHICLE SERVICE ROAD REHABILITATION

ELECTRICAL DETAILS 2

CHRIS EDWARDS

M. TIEASKIE

M. DETTMER

S. PERRY

OCT 2026

50 CD

PDX 2026-5 E5.042025D033 103134

SCALE:

PVC CONDUIT UNDER NEW AC STRUCTURAL PAVEMENT

N.T.S.1

SCALE:

MAXIMUM CONDUIT FILL WITH 5KV CONDUCTORS

NONE4SCALE:

L-823 CONNECTOR DETAIL

N.T.S.3

SCALE:

CONDUIT INSTALLATION IN EXISTING AC PAVEMENT - WITH MILL AND INLAY

N.T.S.2

DIGITALLY SIGNED
2026-09-24T06:49:41-0700
Sergio Perry

File details come from the government source that posted it. Updated .