Attachment-O3__Museum_Drawings_Pt3.pdf
PDF 37 MB Posted
- Attached to
- Arch Museum Exhibits (JEFF 199869B) Federal contract opportunity
- Solicitation number
- P16PS00660
About this file
Contract 1 - Museum Drawings Part 3 of 3
View the file
Other files for this federal contract opportunity
Show all 50
Arch Museum Exhibits (JEFF 199869B) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
XX XX
DRAWING SCHEDULE
N.T.S.3
GENERAL AUDIO & VIDEO SYSTEM NOTES
N.T.S.2
PLATE & PANEL CONSTRUCTION CONVENTIONS
N.T.S.1
MUSEUM OF WESTWARD EXPANSION AUDIO AND VIDEO
DRAWING SCHEDULE
Sheet Number Sheet Title Scale
AV010
TABLE OF CONTENTS / SCHEDULE OF
TERMINATIONS
NTS
AV020 AV SCHEDULE OF TERMINATIONS NTS
AV101
ENTRY LEVEL PARTIAL PLAN AV
LOCATIONS - AREA 1.1/1.2/1.3
1/8" = 1'0"
AV102
ENTRY LEVEL PARTIAL PLAN AV
LOCATIONS - AREA1.1/1.2/1.4
1/8" = 1'0"
AV103
MEZZANINE LEVEL PARTIAL PLAN AV
LOCATIONS - AREA 1.2/1.3
1/8" = 1'0"
AV104
MAIN LEVEL PARTIAL PLAN AV
LOCATIONS - AREA 1.2/1.3
1/8" = 1'0"
AV105
MAIN LEVEL PARTIAL PLAN AV
LOCATIONS - AREA 3.1/4.1/2.1
3/8" = 1'0"
AV106
MAIN LEVEL PARTIAL PLAN AV
LOCATIONS - AREA 3.2
1/4" = 1'0"
AV107
MAIN LEVEL PARTIAL PLAN AV
LOCATIONS - AREA 4.1
1/4" = 1'0"
AV108
MAIN LEVEL PARTIAL PLAN AV
LOCATIONS - ROOM 107
1/4" = 1'0"
AV111
ENTRY LEVEL PARTIAL AV RCP
SECURITY
1/4" = 1'0"
AV201
PROGRAM AND PAGING AV
SINGLE-LINE 1
NTS
AV202
PROGRAM AND PAGING AV
SINGLE-LINE 2
NTS
AV203
PROGRAM AND PAGING AV
SINGLE-LINE 3
NTS
AV204
MULTI-PURPOSE ROOM AV
SINGLE-LINE 1
NTS
AV205
MULTI-PURPOSE ROOM AV
SINGLE-LINE 2
NTS
AV206
CONFERENCE ROOMS AV
SINGLE-LINE 1
NTS
AV207
CONFERENCE ROOMS AV
SINGLE-LINE 2
NTS
AV208
DIGITAL SIGNAGE AND VIDEO
SINGLE-LINE 1
NTS
AV209
DIGITAL SIGNAGE AND VIDEO
SINGLE-LINE 2
NTS
AV210
DIGITAL SIGNAGE AND VIDEO
SINGLE-LINE 3
NTS
AV211
PORTABLE AUDIO PERFORMANCE
RACK SINGLE-LINE
NTS
AV212
PORTABLE VIDEO PERFORMANCE
RACK SINGLE-LINE
NTS
AV213 AV OUTPUT DROPBOX SINGLE-LINE NTS
AV301 CONNECTOR PLATE DETAILS AS NOTED
AV302 MOUNTING DETAILS 1 AS NOTED
AV303 RACK DETAILS 1 AS NOTED
AV304 RACK DETAILS 2 AS NOTED
AV305 MOUNTING DETAILS 2 AS NOTED
LOW VOLTAGE RACEWAY SIZING
N.T.S.4
3/4/2016 RFP 150: EXHIBIT SPEAKER WIRING (RFI-0661)1
REFERENCED CONNECTION
SHEET THAT THE OTHER END OF THE CONNECTION IS ON.
IF BLANK IT IS ON THE CURRENT SHEET
"AA" -- TERRAZO FLR BOX PANELS
SCALE 1:21
"AB" -- INFO FLOOR BOX PANELS
SCALE 1:22
"AD" -- PLAZA PANEL
SCALE 1:26
"AE" -- CONF ROOM FB PANELS
SCALE 1:23
"AF01" -- DIST LEARN WALL PANEL
SCALE 1:24
"AF02-05" -- CONF ROOM WALL BOX
SCALE 1:25
PUSH
"AG" -- PROJECTOR PANEL
SCALE 1:27
"AH" -- TOUCH CONTROL PANEL
SCALE 1:28
"AI" -- BUTTON CONTROL PANEL
SCALE 1:29
"AJ" -- PAGING STATION
SCALE 1:210
"AL" -- ALS ANTENNA PANEL
SCALE 1:211
"BK04" -- PA LOUDSPEAKER PANEL
SCALE 1:212
"BX01-05" -- WALL DISPLAY PANELS
SCALE 1:213
"BX06" -- CEILING DISPLAY PANELS
SCALE 1:213
"BW" -- 70V CEILING SPEAKER DETAIL
SCALE 1:41
"BX04" -- OUTDOOR DISPLAY KIOSK MOUNT PATTERN
SCALE 3"=1'0"3
"BKxx" - LOUDSPEAKER MOUNTING DETAIL
SCALE 1"=1'2
AV CONDUIT (3 4") ENTRY
AC CONDUIT (3 4") ENTRY
"ZX" -- MASTER SYSTEM RACK
SCALE 1:81"ZA" -- ENTRY LVL DIST. RACK
SCALE 1:82"ZC" -- MAIN LVL W. DIST. RACK
SCALE 1:83"ZG" -- IR CONFERENCE RACK
SCALE 1:84"ZJ" -- MAIN LVL N. DIST. RACK
SCALE 1:85
"ZE" -- WEST MULTIPURPOSE RACK
SCALE 1:81
"ZF" -- EAST MULTIPURPOSE RACK
SCALE 1:82
PORTABLE AUDIO PERFORMANCE SYSTEM SCALE: 1:83
PORTABLE VIDEO PERFORMANCE SYSTEM SCALE: 1:84
AV OUTPUT DROPBOX SCALE: 1:85
"ZH" -- METRO CONF RM RACK
SCALE 1:86
05/25/2016 RFI #884, RFP #199
M LNO
05/25/2016 RFI #819, RFP #199
M LN
05/25/2016 RFI #819, RFI # 884, RFI # 895, RFP #1992
1. WIRE AND CABLE SHEATH SHALL BE MAINTAINED TO FINAL
DESTINATION. ALL UTP CABLE TERMINATIONS TO MAINTAIN
TWIST OF INDIVIDUAL PAIRS TO WITHIN 3/8" OR LESS OF
FINAL TERMINATION.
2. CABLES INSTALLED IN PLENUM AREAS WITHOUT CONDUIT
SHALL BE PLENUM RATED. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO INSPECT ALL DRAWINGS AND VERIFY
SPACES PLENUM CABLE IS REQUIRED.
3. PROVIDE LABELS FOR ALL TERMINATION BLOCKS, PATCH
PANELS… REFER TO SPECIFICATIONS FOR REQUIREMENTS.
ALL WIRES AND CABLES SHALL BE LABELED WITHIN 6" OF
FINAL TERMINATION. LABELS SHALL BE MACHINE PRINTED,
SELF-LAMINATING TYPE.
4. INSTALL EACH CABLE SET INDICATED BY THE DOCUMENTS
FROM THE OUTLET LOCATION TO THE RESPECTIVE SERVING
TECHNOLOGY SPACE (UNO).
5. ALL WIRING, CABLING, SYSTEM DEVICES AND SYSTEM
CONTROLS SHALL BE INSTALLED IN COMPLIANCE WITH ALL
CODE REQUIREMENTS, MANUFACTURER'S INSTRUCTIONS
AND BEST PRACTICES UNLESS WRITTEN DIRECTION TO THE
CONTRARY IS PROVIDED.
6. WIRING AND CABLING IN CEILING AREAS WHERE CABLE
TRAY IS NOT SPECIFIED SHALL BE PROPERLY SUPPORTED
BY CONDUIT. CABLES SHALL BE FULLY SUPPORTED USING
ONLY CABLE TRAYS OR CONDUITS. J-HOOKS ARE NOT AN
ACCEPTABLE MEANS OF SUPPORT. QUANTITY OF CABLES
AND MOUNTING OF HARDWARE SHALL BE IN COMPLIANCE
WITH MANUFACTURER INSTRUCTIONS AND SPECIFIED
MAXIMUM FILL RATIOS.
7. IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSPECT
ALL CABLE PATHWAYS PRIOR TO INSTALLATION OF CABLING
AND VERIFY PATHWAYS HAS BEEN INSTALLED IN
CONFORMANCE WITH THE DOCUMENTS.
8. CONTRACTOR SHALL VERIFY PATHWAYS ARE INSTALLED IS
SUCH A MANNER THAT CABLING DOES NOT EXCEED
MAXIMUM ALLOWABLE DISTANCES.
9. CONTRACTOR SHALL INSPECT PATHWAYS AND VERIFY ALL
REQUIRED PROTECTIVE BUSHINGS, GROUNDING BUSHINGS,
RADIUS LIMITERS, ETC. HAVE BEEN INSTALLED PRIOR TO
CABLE INSTALLATION
10. SIGNAL / CABLE TYPES SHALL NOT BE MIXED. PROVIDE
INDEPENDENT PATHWAYS FOR ALL COPPER/UTP, OPTICAL
FIBER, A/V CABLING.
11. CONTRACTOR SHALL PROVIDE A CATEGORY 6 CABLING
SOLUTION.
11. CONTRACTOR SHALL NOT “MIX” MANUFACTURERS. ALL
CABLING AND CONNECTIVITY SHALL BE FROM A SINGLE
MANUFACTURER.
12. CONTRACTOR SHALL PROVIDE MANUFACTURERS'
EXTENDED APPLICATIONS ASSURANCE WARRANTY FOR THE
SYSTEM INSTALLED.
13. MANUFACTURERS' EXTENDED WARRANTY SHALL APPLY TO
ALL CABLING AND CONNECTIVITY PRODUCTS INSTALLED.
14. MANUFACTURERS' EXTENDED WARRANTY SHALL BE FOR A
MINIMUM OF TWENTY-YEARS FROM OWNERS FINAL
ACCEPTANCE
15. THIS FACILITY REQUIRES PHYSICAL SEPARATION FOR
SEVERAL ENTITIES AND NETWORKS.
16. CABLING FOR DIFFERENT ENTITIES SHALL NOT OCCUPY THE
SAME RACEWAY. CABLING, RACEWAYS AND SUPPORTS FOR
THE FOLLOWING SHALL BE SEPARATE:
A. NATIONAL PARK SERVICES
B. JNPA
C. METRO
D. AUDIOVISUAL
E. SECURITY
TELECOMMUNICATIONS DRAWING LIST
SHEET NUMBER SHEET NAME
TT-000
DRAWING LIST, NOTES AND SYMBOL LIST
TT-001
DRAWING LIST, NOTES AND SYMBOL LIST
TT-002 TELECOM MAIN LEVEL ZONE PLAN
TT-003 TELECOM MEZZANINE LEVEL ZONE PLAN
TT-004 TELECOM ENTRY LEVEL ZONE PLAN
TT-097 TELECOM MECHANICAL TUNNEL PLAN
TT-098 TELECOM LOWER LOADING PLAN
TT-099 TELECOM LOAD LEVEL OVERALL PLAN
TT-100 TELECOM MAIN LEVEL OVERALL FLOOR PLAN
TT-101 TELECOM MEZZANINE LEVEL OVERALL FLOOR PLAN
TT-102 TELECOM ENTRY LEVEL OVERALL FLOOR PLAN
TT-103 TELECOM ROOF LEVEL OVERALL FLOOR PLAN
TT-104 TELECOM MAIN LEVEL OVERALL RCP
TT-105 TELECOM MEZZANINE LEVEL OVERALL RCP
TT-106 TELECOM ENTRY LEVEL OVERALL RCP
TT-120 TELECOM MAIN LEVEL PARTIAL PLAN
TT-121 TELECOM MAIN LEVEL PARTIAL PLAN
TT-122 TELECOM MAIN LEVEL PARTIAL PLAN
TT-123 TELECOM MEZZANINE LEVEL PARTIAL PLAN
TT-124 TELECOM MEZZANINE LEVEL PARTIAL PLAN
TT-125 TELECOM MEZZANINE LEVEL PARTIAL PLAN
TT-126 TELECOM ENTRY LEVEL PARTIAL PLAN
TT-127 TELECOM ENTRY LEVEL PARTIAL PLAN
TT-128 TELECOM ENTRY LEVEL PARTIAL PLAN
TT-129 TELECOM ENTRY LEVEL PARTIAL PLAN
TT-130 TELECOM MAIN LEVEL PARTIAL PLAN
TT-131 TELECOM MAIN LEVEL PARTIAL PLAN
TT-132 TELECOM MAIN LEVEL PARTIAL PLAN
TT-133 TELECOM MAIN LEVEL PARTIAL PLAN
TT-134 TELECOM MAIN LEVEL PARTIAL PLAN
TT-134.1 TELECOM MAIN LEVEL PARTIAL PLAN
TT-135 TELECOM MAIN LEVEL PARTIAL PLAN
TT-136 TELECOM MAIN LEVEL PARTIAL PLAN
TT-137 TELECOM MAIN LEVEL PARTIAL PLAN
TT-138 TELECOM MAIN LEVEL PARTIAL PLAN
TT-143 TELECOM MUSEUM STORE LOWER LEVEL PLANS
TT-159 TELECOM MUSEUM STORE LOWER LEVEL RCP
TT-160 TELECOM MAIN LEVEL PARTIAL RCP
TT-161 TELECOM MAIN LEVEL PARTIAL RCP
TT-162 TELECOM MAIN LEVEL PARTIAL RCP
TT-163 TELECOM MEZZANINE LEVEL PARTIAL RCP
TT-164 TELECOM MEZZANINE LEVEL PARTIAL RCP
TT-165 TELECOM MEZZANINE LEVEL PARTIAL RCP
TT-166 TELECOM ENTRY LEVEL PARTIAL RCP
TT-167 TELECOM ENTRY LEVEL PARTIAL RCP
TT-168 TELECOM ENTRY LEVEL PARTIAL RCP
TT-169 TELECOM ENTRY LEVEL PARTIAL RCP
TT-170 TELECOM MAIN LEVEL PARTIAL RCP
TT-171 TELECOM MAIN LEVEL PARTIAL RCP
TT-172 TELECOM MAIN LEVEL PARTIAL RCP
TT-173 TELECOM MAIN LEVEL PARTIAL RCP
TT-174 TELECOM MAIN LEVEL PARTIAL RCP
TT-174.1 TELECOM MAIN LEVEL PARTIAL RCP
TT-175 TELECOM MAIN LEVEL PARTIAL RCP
TT-176 TELECOM MAIN LEVEL PARTIAL RCP
TT-177 TELECOM MAIN LEVEL PARTIAL RCP
TT-178 TELECOM MAIN LEVEL PARTIAL RCP
TT-300 TELECOM ENLARGED ROOM PLANS
TT-300A TELECOM ENLARGED ROOM PLANS
TT-301 TELECOM ENLARGED ROOM PLANS
TT-301A TELECOM ENLARGED ROOM PLANS
TT-302 TELECOM ENLARGED ROOM PLANS
TT-302A TELECOM ENLARGED ROOM PLANS
TT-303 TELECOM ENLARGED ROOM PLANS
TT-303A TELECOM ENLARGED ROOM PLANS
TT-304 TELECOM ENLARGED ROOM PLANS
TT-304A TELECOM ENLARGED ROOM PLANS
TT-306 TELECOM ENLARGED ROOM PLANS
TT-306 TELECOM ENLARGED ROOM PLANS
TT-307 TELECOM ENLARGED ROOM PLANS
TT-308 TELECOM ENLARGED ROOM PLANS
TT-308A TELECOM ENLARGED ROOM PLANS
TT-311 TELECOM ENLARGED ROOM PLANS
TT-311A TELECOM ENLARGED ROOM PLANS
TT-312 TELECOM ENLARGED ROOM PLANS
TT-312A TELECOM ENLARGED ROOM PLANS
TT-400 TELECOM RISER DIAGRAM
TT-400A TELECOM RISER DIAGRAM
TT-401 TELECOM RISER DIAGRAM
TT-402 TELECOM RISER DIAGRAM
TT-403 TELECOM RISER DIAGRAM
TT-403A TELECOM RISER DIAGRAM
TT-500 TELECOM DETAILS
TT-501 TELECOM DETAILS
TT-502 TELECOM DETAILS
TT-503 TELECOM DETAILS
TT-504 TELECOM DETAILS
TT-505 TELECOM DETAILS
MUSEUM OF WESTERN EXPANSION
TELECOMMUNICATIONS DRAWINGS
1. WHERE EXACT DIMENSIONS ARE NOT INDICATED, THE SCALE OF THIS DRAWING
IS SUFFICIENTLY ACCURATE FOR DETERMINING THE LOCATION OF EQUIPMENT,
JUNCTION BOXES, OUTLET BOXES, WIREWAYS, PANELS, ETC. WHERE EXACT
DIMENSIONS ARE INDICATED, THE REFERENCE SURFACE SHALL BE FINAL
FINISHED SURFACE INCLUDING ANY ACOUSTICAL TREATMENTS. ROOM
DIMENSIONS ON THE DRAWINGS HAVE BEEN TAKEN FROM PRELIMINARY
ARCHITECTURAL DRAWINGS. ALL DIMENSIONS SHALL BE VERIFIED AND ANY
DEVIATIONS CAUSING CHANGES EXCEEDING 3-INCHED SHALL BE COORDINATED
WITH THE CONTRACTING OFFICER.
2. DIMENSIONS SHOWN ARE SUGGESTED PLACEMENTS AND ARE PROVIDED FOR
INFORMATION PURPOSES ONLY. COORDINATE ALL DEVICES AND DIMENSIONED
LOCATIONS WITH ARCHITECTURAL AND ENGINEERING DRAWINGS.
3. DRAWINGS ARE NOT TO BE USED FOR ARCHITECTURAL OR ENGINEERING
PURPOSES. DRAWINGS SHALL ONLY BE USED FOR TECHNOLOGY SYSTEM
INSTALLATION AND COORDINATION WITH OTHER CONTRACTORS AND SYSTEMS.
COORDINATE PATHWAYS FOR ALL TECHNOLOGY RELATED DEVICES WITH THE
ARCHITECTURAL AND ENGINEERING PLANS.
4. ALL TECHNOLOGY DEVICES SHALL BE SECURELY MOUNTED PLUMB AND SQUARE
TO WALLS, FLOORS OR RACKS PER THE MANUFACTURERS' RECOMMENDED
MOUNTING PRACTICES.
5. ALL EQUIPMENT SHOWN IN PHANTOM IS FOR REFERENCE ONLY.
6. FIRESTOPS SHALL BE INSTALLED IN ALL SLAB AND WALL PARTITION
PENETRATIONS PROVIDED FOR THE INSTALLATION OF CABLE. FIRESTOPS SHALL
MAINTAIN THE RATING OF THE SLAB OR WALL PARTITION. REVIEW
ARCHITECTURAL PLANS FOR PARTITION TYPES.
7. ALL FIRESTOP SYSTEMS/ASSEMBLIES USED FOR ALL PENETRATIONS SHALL BE
APPROVED BY THE AHJ.
8. ALL ELECTRICAL REQUIREMENTS FOR TECHNOLOGY SHALL BE INSTALLED IN
ACCORDANCE WITH LOCAL ELECTRICAL CODES.
9. ALL DEVICES SHOWN INCLUDING RACKS, WIREWAYS, CONDUITS, ETC. SHALL BE
INSTALLED IN ACCORDANCE WITH LOCAL SEISMIC REQUIREMENTS.
10. REFER TO TELECOMMUNICATIONS SPECIFICATION FOR INSTALLATION
INSTRUCTIONS FOR FLOORBOXES, JUNCTION BOXES, PLYWOOD PANELS,
GROUNDING CONDUCTORS, BUSBARS, CONDUITS, CABLE TRAYS AND METALLIC
ENCLOSURES.
11. ELECTRICAL FEEDS SHALL NOT BE RUN PARALLEL TO VIDEO AND/OR AUDIO
LINES OR RACEWAYS. IF ELECTRICAL FEEDS MUST BE RUN PARALLEL TO
AUDIO/VIDEO LINES, A MINIMUM OF 4' - 0” OF SEPARATION SHALL BE MAINTAINED.
12. REFER TO SPECIFICATIONS FOR SEPARATION REQUIREMENTS FOR
TELECOMMUNICATIONS CABLING.
13. POWER BREAKER PANELS ARE SIZED AND SPECIFIED BY THE ELECTRICAL
ENGINEER, REFER TO ELECTRICAL DRAWINGS. ALL CIRCUITS SHALL BE
PROTECTED BY 120VAC, 20 AMP BREAKERS (UNO).
14. POWER RECEPTACLES SHOWN ON TECHNOLOGY DRAWINGS ARE DEDICATED TO
SPECIFIC TECHNOLOGY EQUIPMENT AND ARE SHOWN FOR REFERENCE ONLY.
THESE RECEPTACLES SHOULD BE ISOLATED GROUND / COMMON PHASE. REFER
TO ELECTRICAL DRAWINGS FOR ADDITIONAL POWER UTILITY RECEPTACLES.
15. WHERE POWER CIRCUITS ARE SHOWN TERMINATING INTO JUNCTION BOXES
WITHOUT RECEPTACLES, THE WIRES SHALL BE CAPPED AND THE BOXES
COVERED. THESE CIRCUITS WILL BE CONNECTED BY OTHERS DURING
INSTALLATION OF THE TECHNOLOGY SYSTEM EQUIPMENT.
16. GROUND ALL CONDUITS, CABLE TRAYS, LADDER RACKS, RELAY RACKS,
CABINETS AND JUNCTION BOXES PER THE MANUFACTURER'S
RECOMMENDATIONS AND PER ALL APPLICABLE CODES.
17. ALL EMPTY CONDUITS SHALL BE REAMED, CLEANED AND CAPPED (WHERE
APPROPRIATE), TAGGED AND FURNISHED WITH PULL LINES.
18. INSTALL CABLE TRAY FOR TELECOMMUNICATIONS WIRING TO MAINTAIN A
MINIMUM OF 5” SEPARATION FROM FLUORESCENT LIGHTING.
19. THERE SHALL BE A MINIMUM OF ONE PULL BOX FOR EVERY 100' OF STRAIGHT
EMPTY CONDUIT AND/OR ONE PULL BOX FOR MORE THAN TWO 90° BENDS OR
LESSER BENDS TOTALING 180° IN A CONDUIT RUN.
20. MAINTAIN MINIMUM BEND RADIUS OF 10X O.D. FOR ALL CONDUITS LESS THAN 4”.
21. MAINTAIN MINIMUM BEND RADIUS OF 48” FOR ALL CONDUITS OF 4” O.D.
22. ALL 4” O.D. CONDUITS SHALL BE PROVIDED WITH A 5/8” PULL-TAPE HAVING A
MINIMUM TENSILE STRENGTH OF 1800 LBS. PULL-TAPE SHALL HAVE FOOTAGE
MARKINGS.
23. ALL CONDUITS LESS THAN 4” O.D. SHALL BE PROVIDED WITH A PULL-LINE.
PULL-LINE SHALL HAVE A MINIMUM TENSILE STRENGTH OF 210 LBS.
24. STUB UP CONDUIT SLEEVES THROUGH SLAB 3” ABOVE FINISHED FLOOR, EXCEPT
IN THE CASE OF ACCESS FLOOR, IN WHICH CASE STUB UPS SHALL TERMINATE
UNDER THE ACCESS FLOOR.
25. ALL CABLE TRAY THAT IS SURFACE MOUNTED ON SLAB BELOW ACCESS FLOOR
SHALL BE PROVIDED WITH SUPPORTS. SUPPORTS SHALL BE SECURELY
FASTENED TO THE SLAB AND CABLE TRAY SHALL BE FASTENED TO THE
SUPPORTS.
26. PROVIDE ALL CABLE BASKET TRAY CONNECTION HARDWARE, GROUNDING LUGS,
GROUNDING STRAPS, THERMAL EXPANSION PLATES, SUPPORT BRACKETS,
SPLICE HARDWARE, TERMINATION KITS, END SUPPORT KITS, CEILING SUPPORT
HARDWARE AND CABLE BEND RADIUS LIMITING DEVICES FOR ALL CABLE TRAY
LOCATIONS PER MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE
CODES.
27. PROVIDE ALL CABLE RUNWAY CONNECTION HARDWARE, GROUNDING LUGS,
GROUNDING STRAPS, THERMAL EXPANSION PLATES, SUPPORT BRACKETS,
SPLICE HARDWARE, TERMINATION KITS, END SUPPORT KITS, CEILING SUPPORT
HARDWARE, 7” CABLE RETAINING POSTS AND CABLE BEND RADIUS LIMITING
DEVICES FOR ALL CABLE RUNWAY LOCATIONS PER MANUFACTURER'S
RECOMMENDATIONS AND APPLICABLE CODES.
28. ALL POWER CONDUIT, POWER WIREWAYS AND POWER JUNCTION BOXES ARE TO
BE REVIEWED BY THE ELECTRICAL ENGINEER FOR CODE COMPLIANCE.
31 EMPTY CONDUIT RUNS ON THE TECHNOLOGY DRAWINGS SHOW ONLY
INTERCONNECTION BETWEEN TERMINATION POINTS. THE EXACT PATH OF THE
CONDUITS IS TO BE DETERMINED BY THE ELECTRICAL ENGINEER AND FIELD
CONDITIONS.
32. ALL CABLES ARE TO BE IN CONDUIT IN NON-ACCESSIBLE SPACES AND SHALL
ROUTE TO TR'S OR TO CABLE TRAY INCLUDING HORIZONTAL AND VERTICAL
RUNS. HORIZONTAL CABLES ONLY, IN ACCESSIBLE SPACES SHALL ROUTE IN
CABLE TRAY..
33. NOTIFY CONTRACTING OFFICER ON ANY DISCREPANCIES BETWEEN EXISTING
CONDITIONS AND THE TECHNOLOGY DRAWINGS. OBTAIN CLARIFICATION
BEFORE PROCEEDING WITH WORK.
34. CONTRACTOR SHALL RESTORE CEILINGS, WALLS AND ANY OTHER SURFACES
AFFECTED BY ITS WORK UPON COMPLETION OF WORK WITH LIKE MATERIALS TO
MATCH EXISTING CONDITIONS.
35. REFER TO A-700 SERIES PLANS FOR FLOOR BOX LOCATIONS, TYPES AND
DETAILS.
36. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY SIGNAL /
CONDUIT PATHWAYS WITH THE ELECTRICAL ENGINEERING DRAWINGS.
37. CONTRACTOR SHALL PROVIDE A TELECOMMUNICATIONS GROUNDING AND
BONDING SYSTEM IN ACCORDANCE WITH ANSI/TIA-607-B STANDARDS.
38. ALL CONDUITS USED FOR TELECOMMUNICATIONS / AV / SECURITY CABLING
SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH ANSI/TIA-607-B
STANDARDS. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY GROUNDING
DEVICES ARE INSTALLED PRIOR TO CABLING INSTALLATION.
39. ALL CONDUITS USED FOR TELECOMMUNICATIONS / AV / SECURITY CABLING
SHALL BE PROVIDED WITH PROTECTIVE BUSHINGS AT ALL TERMINATION POINTS
INCLUDING BUT NOT LIMITED TO ALL JUNCTION BOXES, PULL-BOXES AND WALL
BOXES. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY PROTECTIVE
BUSHINGS ARE INSTALLED PRIOR TO CABLING INSTALLATION.
40. ALL PLYWOOD BACKBOARDS IN TECHNOLOGY ROOMS SHALL HAVE (2) COATS OF
FIRE RETARDANT PAINT APPLIED TO ALL 6 SIDES PRIOR TO MOUNTING. FIRE
RETARDANT PAINT SHALL BE WHITE IN COLOR. CONTRACTOR SHALL MASK (1)
FIRE RATED STAMP ON EACH PLYWOOD BACKBOARD INSTALLED PRIOR TO
PAINTING. MASKING TAPE SHALL BE REMOVED AFTER PLYWOOD BACKBOARD
INSTALLATION
41. ALL PARTS AND/OR ACCESSORIES SHALL BE UL LISTED AND RATED FOR THE
ENVIRONMENT IN WHICH THEY ARE INSTALLED.
42. REFER TO ELECTRICAL SHEETS E-002 AND E-003 FOR THE CONSOLIDATED
RESPONSIBILITY MATRIX FOR COORDINATION OF ROUGH-IN FOR FACILITY AND
EXHIBIT AUDIO/VISUAL, NETWORK, RADIO, STRUCTURED CABLING, ACCESS
CONTROL/INTRUSION DETECTION AND VIDEO SURVEILLANCE SYSTEMS.
1. A UNIFIED TECHNOLOGY GROUNDING AND BONDING SYSTEM SHALL BE
INTEGRATED WITH AND PROVISIONED IN ADDITION TO THE ELECTRICAL
GROUNDING SYSTEM FOR THE SPACE.
2. THE GROUNDING AND BONDING SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH ANSI/TIA-607-B STANDARD “COMMERCIAL BUILDING
GROUNDING AND BONDING FOR TELECOMMUNICATIONS.
3. THE FOLLOWING IS REQUIRED FOR A TELECOMMUNICATIONS
GROUNDING AND BONDING SYSTEM:
A. A PRE-DRILLED MINIMUM 24” X 4” X ¼” SOLID COPPER BUS-BAR
WITH PLEXIGLASS COVER (STENCILED “TMGB”), WALL-MOUNTED
ON INSULATED STANDOFFS. TMGB SHALL BE INSTALLED IN THE
SERVICE ENTRANCE ROOM.
B. MULTIPLE PRE-DRILLED MINIMUM 24” X 2” X ¼” SOLID COPPER
BUS-BAR WITH PLEXIGLASS COVER (STENCILED “TGB”),
WALL-MOUNTED ON INSULATED STANDOFFS. INSTALL A MINIMUM
OF ONE IN EACH TELECOMMUNICATIONS ROOM, EQUIPMENT
ROOM, AND AS REQUIRED THROUGHOUT THE SPACE.
4. THE TMGB SHALL BE PROVIDED WITH A CONTINUOUS COPPER BONDING
CONDUCTOR BONDED TO THE MAIN ELECTRICAL SERVICE GROUND
LOCATED IN THE BUILDING'S ELECTRICAL SERVICE ROOM AS SPECIFIED
BY THE ELECTRICAL ENGINEER.
5. A CONTINUOUS TELECOMMUNICATIONS BONDING BACKBONE SHALL
ROUTE FROM THE TMGB TO THE FARTHEST TGB LOCATED WITHIN THE
BUILDING'S TECHNOLOGY SPACES.
6. WHERE POSSIBLE THE TBB SHALL BE INSTALLED AS A SINGLE
CONTINUOUS CONDUCTOR WITHOUT SPLICES. WHERE INSTALLATION OF
A SINGLE CONTINUOUS TBB CONDUCTOR IS NOT POSSIBLE OR
PRACTICAL THE NUMBER OF SPLICES SHALL BE KEPT TO A MINIMUM.
WHERE NECESSARY, SPLICES SHALL BE MADE ACCESSIBLE WITHIN THE
TECHNOLOGY SPACES. JOINED SEGMENTS SHALL BE CONNECTED
USING EXOTHERMIC WELDING, IRREVERSIBLE COMPRESSION-TYPE
CONNECTORS, OR EQUIVALENT.
7. ALL INTERMEDIATE TGB'S LOCATED THROUGHOUT THE BUILDING SHALL
BE ATTACHED TO THE TBB WITH A SHORT SEGMENT CONDUCTOR EQUAL
TO THE TBB WITH A TWO-HONE IRREVERSIBLE COMPRESSION TYPE
CONNECTOR TERMINATING AT THE BUS-BAR AND CONNECTED TO THE
TBB USING EXOTHERMIC WELDING, IRREVERSIBLE COMPRESSION-TYPE
CONNECTORS, OR EQUIVALENT.
8. ALL CONNECTIONS MADE TO THE RESPECTIVE BUS-BARS SHALL BE
ACCOMPLISHED WITH A TWO-HOLE GROUNDING LUG THAT IS
PERMANENTLY ATTACHED (HYDRAULICALLY CRIMPED) TO THE LEADING
CONDUCTOR.
9. ALL BUS-BARS SHALL BE POSITIONED TO THE SIDE OF THE LOCAL PANEL
BOARD SERVING THE DEDICATED EQUIPMENT POWER (WHEN PROVIDED
WITHIN THE ROOM). BOND THE TMGB/TGBS TO THE LOCAL PANEL'S
ACEG BUS (WHERE PROVIDED). OTHERWISE, BOND EACH BUS-BAR TO
THE METAL FRAME OF THE BUILDING USING A MINIMUM #6 AWG OR
LARGER CONDUCTOR (BASED ON LENGTHS DEFINED WITHIN THE
STANDARDS.
10. INTERIOR WATER PIPES SHALL NOT BE USED AS AN APPROVED
GROUNDING POINT FOR ANY OF THE REFERENCED BUILDING BONDING
CONDUCTORS.
11. ALL METALLIC CONDUITS, EQUIPMENT RACKS, EQUIPMENT CABINETS,
LADDER RACK, METALLIC BACKBONE CABLE SHEATH COMPONENTS,
ENTRANCE PROTECTION UNITS AND CABLE TRAY ENTERING OR LOCATED
WITHIN THE VARIOUS TECHNOLOGY SPACES SHALL BE BONDED TO THE
TMGB/TGB WITH A MINIMUM #6 AWG STRANDED, INSULATED (GREEN)
GROUNDING CONDUCTOR.
12. ALL BUS-BARS, ATTACHED CONDUCTORS AND SPLICE POINTS SHALL BE
LABELED IN ACCORDANCE WITH ANSI/TIA-606-A ADMINISTRATION
STANDARD FOR COMMERCIAL TELECOMMUNICATIONS INFRASTRUCTURE.
13. CABLE TRAYS / CABLE RUNWAY (LADDER RACK) SHALL BE GROUNDED
USING A MINIMUM #6 AWG STRANDED GROUNDING CONDUCTOR.
14. EACH SEGMENT OF THE CABLE TRAYS / CABLE RUNWAY (LADDER RACK)
SHALL BE BONDED TOGETHER USING A MINIMUM #6 AWG STRANDED
GROUNDING CONDUCTOR OR MANUFACTURER APPROVED GROUNDING
STRAP.
15. EACH GROUNDING / BONDING CONDUCTOR ATTACHED TO THE TMGB/TGB
SHALL BE CONNECTED USING AN INDIVIDUAL LUG. MULTIPLE
CONDUCTORS TERMINATED IN A SINGLE LUG SHALL NOT BE ALLOWED.
16. “DAISY-CHAINING” OF CONDUCTORS SHALL NOT BE ALLOWED.
17. ALL LUGS ATTACHED TO THE TMGB/TGB SHALL BE INDIVIDUALLY BOLTED
TO THE BUS-BAR. MULTIPLE LUGS CONNECTED USING A SINGLE SET OF
BOLT HOLES SHALL NOT BE ALLOWED.
19. GROUNDING SHALL COMPLY WITH ANSI/TIA 607-B
1. CONTRACTOR SHALL IDENTIFY ALL CABLING USED FOR TELECOMMUNICATIONS PRIOR TO DEMOLITION.
2 CONTRACTOR SHALL MARK, IDENTIFY AND PROTECT ALL CABLING USED FOR TELECOMMUNICATIONS PRIOR TO DEMOLITION.
3. CONTRACTOR SHALL NOT DISCONNECT, CUT OR REMOVE ANY CABLING USED FOR TELECOMMUNICATIONS WITHOUT PRIOR
CONSENT FROM THE NATIONAL PARK SERVICE.
A/E - ARCHITECT / ENGINEER (DESIGNER)
AFC - ABOVE FINISHED CEILING
AFF - ABOVE FINISHED FLOOR
AFP - ABOVE FINISHED PLATFORM
AHJ - AUTHORITY HAVING JURISDICTION
ANSI - AMERICAN NATIONAL STANDARDS
INSTITUTE
AS - ABOVE SLAB
A/V - AUDIOVISUAL
BFC - BELOW FINISHED CEILING
BICSI - BUILDING INDUSTRY CONSULTING
SERVICE INTERNATIONAL
BSSH - BUILDING STANDARD SWITCH HEIGHT
BSRH - BUILDING STANDARD RECEPTACLE
HEIGHT
CLG - CEILING
EC - EMPTY CONDUIT
GND - GROUND
HH - HAND HOLE
ID - INSIDE DIAMETER
IDF - INTERMEDIATE DISTRIBUTION FRAME
IEEE - INSTITUTE OF ELECTRICAL AND
ELECTRONICS ENGINEERS
IP - INTERNET PROTOCOL
ISP - INSIDE PLANT CABLE
IT - INFORMATION TECHNOLOGY
ITSIMM - INFORMATION TRANSPORT SYSTEMS
INSTALLATION METHODS MANUAL
LOMMF - LASER OPTIMIZED MULTIMODE OPTICAL
FIBER
MC - MAIN CROSS CONNECT
MH - MAINTENANCE HOLE
MPOE - MINIMUM POINT OF ENTRY
MTER - MAIN TELECOMMUNICATIONS
EQUIPMENT ROOM
NDRM - NETWORK DESIGN REFERENCE MANUAL
NEC - NATIONAL ELECTRIC CODE
NEMA - NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NESC - NATIONAL ELECTRIC SAFETY CODE
NFPA - NATIONAL FIRE PROTECTION
ASSOCIATION
NIC - NOT IN CONTRACT
OC - ON CENTER
OD - OUTSIDE DIAMETER
OFE - OWNER FURNISHED EQUIPMENT
OSP - OUTSIDE PLANT CABLE
OSPRDM - OSP DESIGN REFERENCE MANUAL
PB - PULL BOX
POE - POWER OVER ETHERNET
RCDD - REGISTERED COMMUNICATIONS
DISTRIBUTION DESIGNER
ROHS - RESTRICTION OF HAZARDOUS
SUBSTANCES.
RW - RACEWAY
SCTP - SCREENED TWISTED PAIR
SMF - SINGLEMODE OPTICAL FIBER
SSER - SATELLITE SERVICE ENTRANCE ROOM
STP - SHIELDED TWISTED PAIR
TDMM - TELECOMMUNICATIONS DISTRIBUTION
METHODS MANUAL
TDR - TIME DOMAIN REFLECTOMETER
TEMP - TEMPORARY
TGB - TELECOMMUNICATIONS GROUNDING
BUSBAR
TIA - TELECOMMUNICATIONS INDUSTRY
ASSOCIATION
TMGB - TELECOMMUNICATIONS MAIN
GROUNDING BUSBAR
TR - TELECOMMUNICATIONS ROOM
TSER - TELECOMMUNICATIONS SERVICE
ENTRANCE ROOM
TYP - TYPICAL
UL - UNDERWRITERS LABORATORY
UNO - UNLESS OTHERWISE NOTED
UPS - UNINTERRUPTABLE POWER SUPPLY
UTP - UNSHIELDED TWISTED PAIR
WDRM - WIRELESS DESIGN REFERENCE MANUAL
WOA - WORK AREA OUTLET
WP - WATERPROOF
WW - WIREWAY
1. TELECOMMUNICATIONS OUTLETS FOR NATIONAL PARK SERVICES ARE DESIGNATED THE LETTER "N".
2. TELECOMMUNICATIONS OUTLETS FOR JNPA ARE DESIGNATED THE LETTER "J".
3. TELECOMMUNICATIONS OUTLETS FOR METRO ARE DESIGNATES THE LETTER "M".
4. TELECOMMUNICATIONS OUTLETS FOR AUDIOVISUAL ARE DESIGNATED THE LETTER "A".
5. TELECOMMUNICATIONS OUTLETS FOR SECURITY ARE DESIGNATED THE LETTER "S".
EXAMPLES:
WALL MOUNTED OUTLET FOR NATIONAL PARK SERVICE
CEILING MOUNTED OUTLET FOR JNPA
FLOOR MOUNTED OUTLET FOR METRO
DEFINES THE OUTLET CONFIGURATION
1. ALL AV OUTLETS MARKED A-B, A-C, OR A-D WILL REQUIRE A 20' PATCH CORD FROM OUTLET INTO MILLWORK.
05/13/2016 RFI #895, RFP #199
M L
2 05/25/2016 RFI #884, RFP #199
05/25/2016 RFI #819, RFP #199
07/06/2016 RFI 882, RFP 246
05/25/2016 RFI #895, RFP #1991
RFI #811
01/15/2016 RFP #082 - JNPA DATA NEEDS1
BUILDING GROUNDING
ELECTRODE SYSTEM
(BY OTHERS)
TGB 1 (BY OTHERS)
EQUIPMENT RACKS LADDER RACK
PANELS SERVING
TELECOM ROOMS
ALL TELECOM
SLEEVES AND
RACEWAYS
TYPICAL EQUIPMENT BONDED
TO ALL TGB'S AND TMGB
(TYPICAL FOR ALL FLOORS IN
CONTRACT)
N-POP / TR-2A
GROUNDING CONDUCTOR SIZING
LINEAR LENGTH (ft) CONDUCTOR SIZE (AWG)
LESS THAN 13 6
14-20 4
21-26 3
27-33 2
34-41 1
42-52 1/0
53-66 2/0
67-84 3/0
CABLE TRAY
MINIMUM #6 AWG COPPER BONDING
CONDUCTOR IN GREEN INSULATED
JACKET
(TYPICAL FOR ALL - SEE TABLE)
BUILDING POWER SYSTEM
MAIN GROUND BUS - ROOM 1EC1
BONDING
CONDUCTOR FOR
TELECOMMUNICATIONS
MIN. SIZE #3/0 AWG
TELECOMMUNICATIONS MAIN
GROUNDING
BUSBAR (TMGB) LOCATED IN TT-302
TELECOMMUNICATIONS BONDING
BACKBONE (TBB) SIZED PER
GROUNDING CONDUCTOR SIZING
TABLE, MIN. SIZE #2 AWG
IRREVISIBLE COMPRESSION
CONNECTOR
TELECOMMUNICATIONS BONDING
BACKBONE CONDUCTOR, SIZED
PER CONDUCTOR SIZING TABLE.
MIN. SIZE #2 AWG BARE
COPPER BONDING
CONDUCTOR (TYP.)
THIS CONNECTION IS NOT REQUIRED
FOR SLEEVES OR RACEWAYS
BONDED TO THE TBB OR GE. SEE
NOTE 3.
CADWELD
BUILDING STEEL
(IF AVAILABLE)
GROUNDING NOTES:
1. ALL BUSBARS SHALL BE SIZED PER SPECIFICATION 27 05 26 (UON) PRE-DRILLED TIN-PLATED COPPER. MOUNT ON WALL WITH 2" STANDOFF INSULATORS AND
PLEXIGLASS.
2. ALL CABLE CONNECTIONS TO TGB'S ARE TWO HOLE LONG BARREL COMPRESSION LUGS, UNLESS OTHERWISE NOTED.
3. BONDING CONDUCTORS SHALL GENERALLY BE RUN OPEN WITH PLASTIC SUPPORTS. WHERE RUN IN STEEL CONDUITS LONGER THAN 36", BOND CONDUIT TO TBB OR GE
AT BOTH ENDS.
4. BONDING CONDUCTORS SHALL BE RUN WITHOUT SPLICES WHEREVER POSSIBLE. ANY SPLICES MUST BE MADE WITH NON-REVERSIBLE COMPRESSION CONNECTORS
OR CADWELD.
5. BONDING CONDUCTORS SHALL BE COPPER CONDUCTORS WITH GREEN INSULATION OR DISTINCTIVE GREEN MARKING, UNLESS OTHERWISE NOTED.
6. THE SIGNAL GROUNDING SYSTEM SHALL BE TIED TO THE INCOMING BUILDING ELECTRICAL SAFETY GROUND AT THE PRIMARY TRANSFORMER NEUTRAL BOND, AND/OR
AT THE NEUTRAL BOND OF ANY SEPARATELY DERIVED SOURCE IN ACCORDANCE WITH APPLICABLE CODE. THE SYSTEM GROUND RESISTANCE SHALL BE LESS THAN 5.0
OHMS. THIS SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/TIA-607-B, GENERIC TELECOMMUNICATIONS BONDING AND GROUNDING (EARTHING)
FOR CUSTOMER PREMISE, AUGUST 2012 AND ANSI/TIA-607-B-1, GENERIC TELECOMMUNICATIONS BONDING AND GROUNDING (EARTHING) FOR CUSTOMER PREMISE., ADDENDUM 1, EXTERNAL GROUNDING, JANUARY 2013,
7. NO SPLICE SHALL BE MADE TO A BACKBONE OR BONDING CONDUCTOR WITHOUT PRIOR APPROVAL OF THE CONTRACTING OFFICER.
85-105 4/0
106-125 250 kcmil
126-150 300 kcmil
151-175 350 kcmil
176-250 500 kcmil
251-300 600 kcmil
GREATER THAN 300 750 kcmil
NOTE:
THE MINIMUM SIZE FOR A
TELECOMMUNICATIONS BONDING
BACKBONE CONDUCTOR IS #2 AWG.
T
Y
P
A
S
R
E
Q
U
I
R
E
D
1"
1 1/8"
2" HIGH RED
STENCILED LETTERING
CLEAR 3/8" THICK
PLEXIGLASS COVER
5/8"-11 x 1-1/2" CONT.
THREADED ROD (TYP)
2-3/4" INSULATOR
9/16" (40) PLACES
5/8-11x1" H.H.C.S.
2-3/4"INSULATOR
7/16" DIA. (20) PLACES
2-3/4"INSULATOR
5/8" DIA.
5/8-11x1" H.H.C.S.
LOCKWASHER
5/8"DIA. (TYP.)
T
G
B
R
A
D
I
U
S
THE RADIUS ON ANY
BEND SHALL NOT BE
LESS THAN 8 INCHES
THE ANGLE OF ANY
BEND SHALL NOT BE
LESS THAN 90 DEGREES
D
G
R
E
S
M
I
N
I
M
U
M
001 - 444 - 5
01 - 033 - 125 - 2
SHEET INDEX: REFER TO TECHNOLOGY INSTALLATION
NOTES, THIS SHEET, FOR DESCRIPTIONS OF DRAWING
AND SPECIFICATION NAMING STRUCTURE FOR RELATED
SYSTEMS SUCH AS T###, TT AND TY SERIES DRAWINGS.
T-000 COVER SHEET TECHNOLOGY
T-001 SITE PLAN - TECHNOLOGY
T-002 MAIN LEVEL EXISTING FLOOR PLAN
T-003 NORTH AND SOUTH LOWER LOADING PLAN
T-002D MAIN LEVEL DEMOLITION PLAN
T-100 MAIN LEVEL FLOOR PLAN
T-101 MEZZANINE LEVEL FLOOR PLAN
T-102 ENTRY LEVEL FLOOR PLAN
T-103 COURT HOUSE BASEMENT FLOOR PLAN
T-120 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-121 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-122 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-130 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-131 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-132 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-133 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-134 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-135 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-136 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-137 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-138 TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-200 ENLARGED MAIN FLOOR PLANS
T-300 TECHNOLOGY DETAILS
T-301 TECHNOLOGY DETAILS
T-302 TECHNOLOGY DETAILS
T-303 TECHNOLOGY DETAILS
T-304 TECHNOLOGY DETAILS
T-400 TECHNOLOGY RISERS
T-401 TECHNOLOGY RISERS
T-402 TECHNOLOGY RISERS
T-403 TECHNOLOGY RISERS
T-404 TECHNOLOGY RISERS
T-405 TECHNOLOGY RISERS
T-406 TECHNOLOGY RISERS
T-500 TECHNOLOGY SCHEDULES
T-501 TECHNOLOGY SCHEDULES
1. "1/T302" INDICATES DETAIL NUMBER / SHEET NUMBER.
2. "SC-SEC-1" INDICATES GENERAL TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED
AS "EQUIPMENT LIST ABBREVIATION.".
3. " " INDICATES KEYED NOTE USED TO DESCRIBE ADDITIONAL INFORMATION OF
WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL IT IS SHOWN WITH.
4. ABBREVIATION KEY:
T.C. TELECOMMUNICATIONS CONTRACTOR, WORK DEFINED IN TT SERIES
DRAWINGS
E.C. ELECTRICAL CONTRACTOR
S.C. SECURITY CONTRACTOR, WORK DEFINED IN TY AND T### SERIES DRAWINGS
N.C. NETWORK CONTRACTOR, WORK DEFINED BY THESE DRAWINGS, T-###
SERIES
AFF ABOVE FINISH FLOOR
TYP TYPICAL
+#" MOUNTING HEIGHT FROM FINISHED FLOOR TO CENTERLINE
NPS NATIONAL PARK SERVICE
DAS DISTRIBUTED ANTENNA SYSTEM
UPS UNINTERRUPTIBLE POWER SUPPLY
RC RADIO CONTRACTOR, DAS AND WI-FI
5. MOUNTING SUBSCRIPT KEY:
1. REFER TO MATERIAL LIST AND SPECIFICATIONS FOR FULL DESCRIPTIONS AND
MANUFACTURERS OF ALL DEVICES.
6. LINE TYPE KEY:
NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS
CONTRACTOR (DARK LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN
(LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK SHORT DASHED LINE)
GENERAL TECHNOLOGY NOTES:
TECHNOLOGY INSTALLATION NOTES:
TECHNOLOGY DEMOLITION NOTES:
TELECOM ROOM REFERENCES
1. THE TECHNOLOGY DRAWINGS INDICATE EXISTING TECHNOLOGY ITEMS TO BE
REMOVED. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF WORK
REQUIRED AND DO NOT INDICATE EVERY BOX, CONDUIT, OR WIRE THAT MUST BE
REMOVED.
2. ITEMS (i.e., SPEAKERS, SWITCHES, ETC) REMOVED AND NOT RELOCATED REMAIN THE
PROPERTY OF THE CONTRACTING OFFICER. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE DISPOSAL OF MATERIAL THE CONTRACTING OFFICER DOES
NOT WANT TO REUSE OR RETAIN. (i.e., FOR MAINTENANCE PROPOSES)
3. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CONTRACTING OFFICER
BEFORE TURNING OFF THE POWER TO EQUIPMENT, SYSTEMS, PANELS, ETC.
COORDINATE ALL OUTAGES WITH CONTRACTING OFFICER. CONDUIT CONCEALED IN
WALL MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY OTHER CONSTRUCTION.
4. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE
CONDUIT IS IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG.
WHERE CONDUIT IS RUN EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS,
ETC., SHALL ALSO BE REMOVED.
5. THIS CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER CONTRACTORS AT
THE JOB SITE BEFORE REMOVING EXISTING ELECTRICAL AND INSTALLING NEW ITEMS.
6. EXISTING CONDUIT IN GOOD CONDITION MAY BE REUSED IN PLACE. RELOCATED
EXISTING CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE
INSTALLED IN ALL REUSED CONDUIT TO ASSURE PROPER GROUND PATH.
7. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A
JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION EXTEND
CONDUIT AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.
8. TECHNOLOGY DEVICES TO BE REMOVED SHALL HAVE ALL CONNECTED WIRING
REMOVED TO THE SOURCE.
9. DEVICES NOT TO BE REMOVED SHALL BE PROTECTED FROM THE ENVIRONMENT, AND
ALL CABLE/RACEWAYS ARE TO REMAIN AND BE PROTECTED. T.C. SHALL BE
RESPONSIBLE FOR REPAIR OF ANY INTERRUPTIONS TO PROTECTED DEVICES.
SYMBOL EQUIPMENT LIST ABBREVIATION DESCRIPTION NOTES:
TECHNOLOGY SYMBOL LIST
GENERAL NOTES:
1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT. REFER TO THE
TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION AND ITEMS.
2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON THE SHEET INDEX.
REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL INFORMATION.
WALL MOUNT,
DIRECTIONAL
WIRELESS ACCESS POINT (WALL MOUNT)SC-WAP-W
WAP
DISTRIBUTED ANTENNA SYSTEM ANTENNA (TYPE 1)DAS-ANT-1
DA1
DISTRIBUTED ANTENNA SYSTEM ANTENNA (TYPE 2)DAS-ANT-2
NA FLOOR RACK
DAS-ANT-3
DISTRIBUTED ANTENNA SYSTEM ANTENNA (TYPE 3)
ER
DAS-ER
EQUIPMENT RACK ENCLOSURE, WALL MOUNT
DIP
DAS-DIP
DISTRIBUTED ANTENNA SYSTEM DIPOLE ANTENNA
ROU
DAS-ROU
DISTRIBUTED ANTENNA SYSTEM REMOTE OPTICAL
UNIT
DUP
DAS-DUP
RADIO TRANSMITTER AND DUPLEXER
DAS
DAS-CTRL
DISTRIBUTED ANTENNA SYSTEM CONTROL
RPT
DAS-RPT
DISTRIBUTED ANTENNA SYSTEM REPEATER
WAP
DA4
DAS-ANT-4
DISTRIBUTED ANTENNA SYSTEM ANTENNA (TYPE 4)
WIRELESS ACCESS POINT (CEILING MOUNT)SC-WAP-C
DA2
DA3
DA5
DAS-ANT-5
DISTRIBUTED ANTENNA SYSTEM ANTENNA (TYPE 5)
DAE NA
DISTRIBUTED ANTENNA SYSTEM ANTENNA, EXISTING
TO BE REMOVED
CEIL. MOUNT,
OMNI DIR.
POLE MOUNT,
YAGI
CEIL. MOUNT,
OMNI DIR.
POLE MOUNT,
YAGI
1. RELATED DRAWINGS:
T-### SERIES: THIS SET, TECHNOLOGY, WHICH DEFINES THE PROVISIONING AND
INSTALLATION OF 1) NETWORK ELECTRONIC EQUIPMENT FOR THE NPS DATA NETWORK, 2)
NETWORK ELECTRONIC EQUIPMENT FOR THE SECURITY NETWORK, 3) VIDEO SURVEILLANCE
RECORDING AND CONTROL, 4) DAS AND WI-FI SYSTEMS, 5) ANALOG PHONE LINE
REQUIREMENTS AND 6) AT&T NET POP CROSS CONNECTION REQUIREMENTS.
T### SERIES: SITE TECHNOLOGY WHICH INCLUDES CABLING AND DEVICES WHICH TERMINATE
TO EQUIPMENT DEFINED IN T-###, TT AND TY SERIES DRAWINGS. T### SERIES DRAWINGS
GENERALLY INCLUDE, BUT ARE NOT LIMITED TO: HORIZONTAL CABLING FOR EXTERIOR SITE
TELECOMMUNICATIONS NEEDS TO TERMINATION POINTS AT OSP/ISP (PLENUM) LOCATIONS,
PROVISIONING AND INSTALLATION OF SITE TECHNOLOGY DEVICES SUCH AS SURVEILLANCE
CAMERAS.
TY-### SERIES:INTERIOR SECURITY DRAWINGS WHICH GENERALLY INCLUDE, BUT ARE NOT
LIMITED TO PROVISIONING AND INSTALLATION OF INTERIOR SECURITY DEVICES SUCH AS
SURVEILLANCE CAMERAS AND ACCESS CONTROL SYSTEMS.
TT-### SERIES: TELECOMMUNICATIONS DRAWINGS WHICH GENERALLY
INCLUDE, BUT ARE NOT LIMITED TO, INTERIOR STRUCTURED CABLING, RACKS, ENCLOSURES
AND HORIZONTAL CABLING FOR GENERAL TELECOMMUNICATIONS AND SECURITY SYSTEMS.
2. SPECIFICATIONS ASSOCIATED WITH T-### SERIES, THIS SET, ARE DIVISIONS 27 AND 28.
CONTRACTOR SHALL COORDINATE WITH WORK DEFINED IN T###, TT-### AND TY-### SERIES
DRAWINGS AS WELL AS THE DIVISIONS 27 AND 28 SPECIFICATIONS ASSOCIATED WITH T###,
TT-### AND TY-### SERIES DRAWINGS
3. TELECOMMUNICATIONS ROOMS ARE REFERENCED BY ARCHITECTURAL ROOM NUMBERS.
4. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE A.D.A.A.C. (AMERICANS
WITH DISABILITIES ACT ACCESSIBLE GUIDELINES)
5. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, AND IN FLOOR SLAB, ETC.
UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN
MECHANICAL ROOMS, AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON
BUILDING STRUCTURE.
6. REFER TO ELECTRICAL DRAWINGS FOR CONSOLIDATED RESPONSIBILITY MATRIX FOR THE
VARIOUS CONTRACTORS.
7. CONTRACTOR SHALL VERIFY ALL FURNITURE, MODULAR FURNITURE AND EQUIPMENT
LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS AND REVIEWED SHOP DRAWINGS.
PRIOR TO MAKING THE ACTUAL INSTALLATION THIS CONTRACTOR SHALL ADJUST OUTLETS OR
CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.
8. EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO ELECTRICAL AND MECHANICAL
EQUIPMENT.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE
EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
SEALED INTO OPENINGS.
10. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL BE
TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
THROUGH-PENETRATION FIRESTOPS.
11. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE
EXECUTION OF TECHNOLOGY WORK. CONTRACTOR SHALL REPLACE CEILING TILES WITH
IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR.
12. EXISTING PUBLIC SAFETY AND MAINTENANCE RADIO SYSTEM SHALL HAVE NO DOWNTIME.
TRANSFER OF CABLING RELATED TO THE RADIO SYSTEM SHALL BE COORDINATED WITH
CONTRACTING OFFICER.
13. RADIO CONTRACTOR SHALL COORDINATE FINAL WAP AND DAS ANTENNA LOCATIONS WITH
ARCHITECT. PRE-CONSTRUCTION COVERAGE MAPS WERE CREATED BASED ON LOCATIONS
DEFINED ON THESE DRAWINGS. AS FINAL CONSTRUCTION MAY HAVE AN EFFECT ON
COVERAGE, RADIO CONTRACTOR IS RESPONSIBLE FOR RELOCATION OF WAP AND DAS
ANTENNAS TO OBTAIN DESIRED COVERAGE.
TECHNOLOGY INSTALLATION NOTES:
14. FOR RACKS AND ENCLOSURES DEFINED IN THE TELECOMMUNICATIONS DRAWINGS, THE
DIMENSIONS OF THOSE ITEMS IN THE TELECOMMUNICATIONS DRAWINGS SUPERCEDE THESE
DRAWINGS.
COVER SHEET - TECHNOLOGY
SITE PLAN - TECHNOLOGYSITE PLAN - TECHNOLOGY
T-001
GENERAL NOTES
KEYNOTES
MAIN LEVEL EXISTING FLOOR PLANMAIN LEVEL EXISTING FLOOR PLAN
T-002
MAIN LEVEL FLOOR PLAN -
DEMOLITION
MAIN LEVEL FLOOR PLAN - DEMOLITION
T-002D
WAP
DA1
A-25
WAP
DA4
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UPUP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UPUPUP
MAIN LEVEL FLOOR PLANMAIN LEVEL FLOOR PLAN
T-100
DA1
DAS-A01-11
WAP
NPS-AP-06
NPS-AP-17
NPS-AP-18
WAP
WAP
WAP
NPS-AP-12
DA2
DAS-A-16
UP
UP
UP
U P
TECHNOLOGY - MAIN LEVEL -
PARTIAL PLAN
TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-120
UP
WAP
NPS-AP-05
WAP
NPS-AP-11
WAP
NPS-AP-10
DA1
DAS-A01-09
DAS-A01-13
DA1
DAS-A0110
ROU
DAS-ROU-3
DAS-A01-14
WAP
NPS-AP-16
DA2
DA2
TECHNOLOGY - MAIN LEVEL -
PARTIAL PLAN
TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-130
NPS-AP-14
WAP
NPS-AP-15
DA1
DAS-A01-04
DA1
DAS-A01-03
DAS-ROU-1
ROU
DAS-A01-05
DA1
DAS-A01-02
DAS-A01-01
DAS
WAP
NPS-AP-1
DA2
DA2
TECHNOLOGY - MAIN LEVEL -
PARTIAL PLAN
TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-131
MTRO-AP-01
WAP
NPS-AP-09
DA1
DAS-A01-07
WAP
NPS-AP-07
WAP
NPS-AP-04
WAP
NPS-AP-25
WAP
NPS-AP-13
WAP
NPS-AP-23
WAP
NPS-AP-28
TECHNOLOGY - MAIN LEVEL -
PARTIAL PLAN
TECHNOLOGY - MAIN LEVEL - PARTIAL PLAN
T-132
GENERAL NOTES
/ RFP-082
RISER DIAGRAM, NPS NETWORK SWITCHES, 1TC6
NO SCALE:
RISER DIAGRAM, NPS NETWORK SWITCHES, 1TC4
NO SCALE:
RISER DIAGRAM, NPS NETWORK SWITCHES, 3TC1
NO SCALE:
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 1TC1
NO SCALE:
RISER DIAGRAM, NPS NETWORK SWITCHES, 313
NO SCALE:
TECHNOLOGY RISERS
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 1TC6
NO SCALE:
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 313
NO SCALE:
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 1TC4
NO SCALE:
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 1TC2
NO SCALE:
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 1TC3
5 NO SCALE:
RISER DIAGRAM, SECURITY NETWORK SWITCHES, 3TC1
NPS DATA NETWORK FIBER OPTIC RISER DIAGRAM
NO SCALE:
SECURITY NETWORK FIBER OPTIC RISER DIAGRAM
ANALOG LINES RISER DIAGRAM
EXISITING RADIO SYSTEM RISER DIAGRAM
DAS RISER DIAGRAM
WIRELESS ACCESS POINT SCHEDULEDAS ANTENNA SCHEDULE
NOTES:
1. NPS-AP-# USED FOR A/V MAINTENANCE SHALL BE SEPARATED FROM NPS DATA/IT NETWORK BY A CONTRACTOR CONFIGURED VIRTUAL
LOCAL AREA NETWORK (VLAN)
2. INTERNET SERVICE PROVIDER AND ROUTER TO BE ARRANGED BY CONTRACTING OFFICER.
TECHNOLOGY SCHEDULES
TECHNOLOGY MATERIAL LIST TECHNOLOGY MATERIAL LIST
TECHNOLOGY SCHEDULES
| FP-100 |
| FP-101 |
| FP-102 |
| FP-103 |
| FP-160_REV02_RFP262r1 |
| FP-167_REV01_RFP262r1 |
| FP-174-RCP-MAIN LEVEL-PARTIAL |
| FP-175-RCP-MAIN LEVEL-PARTIAL |
| FP-176 |
| FPD-134_REV06_RFP029 |
| FPD-135 |
| FPD-136 |
| P-100 |
| P-120_REV02_RFI0400 |
| P-134_REV02_RFP145CR1_RFI1026 |
| P-135_REV02_RFI693 |
| P-136 |
| P-300_REV04_RFP084 |
| PD-134_REV06_RFP029 |
| PD-135_REV02_RFI266 |
| PD-136 |
| AV-010 |
| AV-020_REV02_RFI882_RFP246 |
| AV-104_REV01_RFP150_RFI0661 |
| AV-105 |
| AV-108_REV02_RFI882_RFP246 |
| AV-201 |
| AV-202 |
| AV-203 |
| AV-204 |
| AV-205 |
| AV-206 |
| AV-207 |
| AV-208 |
| AV-209 |
| AV-210 |
| AV-211 |
| AV-212 |
| AV-213 |
| AV-301 |
| AV-302 |
| AV-303 |
| AV-304 |
| AV-305 |
| TY-000 |
| TY-099 |
| TY-100 |
| TY-101 |
| TY-102 |
| TY-120 |
| TY-130_REV01_RFI884_RFP199 |
| TY-131_REV01_RFI819_RFP199 |
| TY-132 |
| TY-134.1 |
| TY-300_REV02_RFI819_RFI884_RFI895_RFP199 |
| TY-301 |
| TY-400 |
| TY-500 |
| TY-501 |
| TY-502 |
| TY-503 |
| TY-504 |
| TY-505 |
| TY-506 |
| TY-507 |
| TY-508 |
| TY-509 |
| TY-600 |
| TY-700 |
| TY-701 |
| TY-702 |
| TY-703_REV01_RFP082 |
| TY-704 |
| TY-705 |
| TY-706 |
| TY-707 |
| TT-000 |
| TT-001_REV02_RFI 358_RFP 093 |
| TT-002 |
| TT-120_REV01_RFP048_RFI0192 |
| TT-127_REV01_RFP048_RFI0192 |
| TT-130_REV02_RFI884_RFP199 |
| TT-131_REV03_RFI819_RFP199 |
| TT-132_REV01_RFP048_RFI0192 |
| TT-170_REV01_RFI882_RFP246 |
| TT-171_REV01_RFI882_RFP246 |
| TT-174_1_REV01_RFI882_RFP246 |
| TT-302_REV01_RFI884_RFP199 |
| TT-400_REV01_RFI811_RFP184 |
| TT-400A |
| TT-401_REV01_RFI811_RFP184 |
| TT-402_REV02_RFI811_RFP184 |
| TT-403_REV01_RFI811_RFP184 |
| TT-403A |
| TT-500 |
| TT-501 |
| TT-502 |
| TT-503 |
| TT-504_REV01_RFI593 |
| TT-505 |
| T-000 |
| T-001 |
| T-002 |
| T-002D |
| T-100 |
| T-120 |
| T-130 |
| T-131 |
| T-132_REV02_RFP082 |
| T-400_REV01_RFI019 |
| T-401 |
| T-402 |
| T-403_REV 01_RFI124 |
| T-404_REV 01_RFI124 |
| T-405 |
| T-406 |
| T-500 |
| T-501 |
File details come from the government source that posted it. Updated .