OPEN
OPEN
A 09/14/16 SPEAKER REMOVED MH
"=1'
FEET
1'
Scale: 1-1/2" = 1'
2'
A
KEY NOTES:
1. SOLID SURFACE BONDED TO FIRE RATED FORMALDEHYDE FREE MDF
SUBSTRUCTURE. SEE DRAWING (Q) MWE 1111.
2. GRAPHIC PANEL.
3. UNIT FIXED TO FLOOR.
4. 46 INCH TOUCH SCREEN UNIT. SEE DRAWING (Q) MWE 1116 AND A/V
LIST FOR DETAILS.
5. LED RECESSED UNDER.
6. KICKER WITH LED EDGE LIGHTING.
7. PUSH BUTTON TO ACTIVATE INTERACTIVE ON DC-8-03 - SEE DRAWING
(D) MWE 3805 FOR MORE DETAILS.
8. OMITTED.
9. SCALE MODEL OF DC-8-03.
NOTES:
FOR TYPICAL ELECTRICAL CONNECTION DETAILS SEE THE (M) DRAWING
SERIES.
POWER IN BOTH UNITS ARE CONNECTED TO THE FLOOR BOX UNDER
ADJACENT TOUCH SCREEN HOUSING
S8
M1
M1 S8
B
AV - AUDIO VISUAL / AUDIO
DC - DISPLAY CASE
PI - PHYSICAL INTERACTIVE
IT - INFORMATION TECHNOLOGY
GL - GRAPHICS LAYOUT
MR - MODEL OR RECONSTRUCTION
INDIVIDUAL PACKAGE TYPES SHOULD BE READ IN
CONJUNCTION WITH THE RELEVANT SPECIFICATIONS
AND LISTS.
SCALES
GL-1-01
Project No.
DRAWING STATUS
Area No.
DWG Type
AUTHOR DATE
RevDWG No.
APPROVED
REV.
BY
NOTESDATEREV.
@ D+
GENERAL DRAWING NOTES
DO NOT SCALE OFF THIS DRAWING
except for the purposes of cost estimating & shop drawing production.
ALL DIMENSIONS TO BE CHECKED ON SITE
ALL DIMENSIONS ARE IN FEET & INCHES
[MILLIMETERS IN SQUARE BRACKETS] UNLESS
OTHERWISE STATED
This drawing shows 'design intent' only.
It is the responsibility of the appointed contractor to finalize development, using specialists approved by Contracting
Officer, & produce detailed shop drawings.
ALL shop drawings to be approved by Contracting Officer prior to manufacture.
All Electrical & data communications systems must conform to the prevailing national regulations & any local bylaws pertaining.
All materials to conform to US national building specification, including fire ratings and spread of flame.
All products specified are for Basis of Design Only. Suitable comparable or similar approved products, may be used.
EXPLANATION OF EXHIBIT CODES
EVERY EXHIBIT ELEMENT IS GIVEN AN IDENTIFICATION
NUMBER OR CODE WHICH UNIQUELY IDENTIFIES IT.
ITEM NUMBER
AREA CODE
EXPLANATION OF PACKAGE TYPE
PACKAGE TYPE
PMIS No. NPS DRAWING No.
M1
EXPLANATION OF DRAWING MARKERS
D1
STANDARD DRAWING NOTE
DETAIL MARKER
FINISHES MARKER REFER TO DRAWING
9489 (Z) MWE 1500
JEFFERSON NATIONAL EXPANSION
MEMORIAL
MUSEUM OF WESTWARD EXPANSION
DRAWING SET NUMBER 366/130323
AREA 8 - BUILDING THE ARCH
DISPLAY TABLES FOR SAARINEN'S
TOUR INTERACTIVE
JB JULY 15, 2016 RW
E MWE 4811 A
BID
A-A
5"
PI-8-05
GL-8-37
PI-8-05
GL-8-37
16 5
3'-10"
1 S8
GL-8-36
MR-8-03
GL-8-36
MR-8-03
M1 5
Scale 1/16"=1'
DISPLAY TABLES FOR SAARINEN'S TOUR INTERACTIVE
LOCATION PLAN
2 3/8"
IT-8-02
IT-8-02
S8
Scale 1-1/2"=1'
B
DISPLAY TABLES FOR SAARINEN'S TOUR INTERACTIVE
ELEVATIONScale 1-1/2"=1'
A
DISPLAY TABLES FOR SAARINEN'S TOUR INTERACTIVE
ELEVATION
Scale 1-1/2"=1'
A-A
DISPLAY TABLES FOR SAARINEN'S TOUR INTERACTIVE
SECTION
Scale 1-1/2"=1'
DISPLAY TABLES FOR SAARINEN'S TOUR INTERACTIVE
PLAN
L14
3' 3'
3'-10"
B-B
Scale 1-1/2"=1'
B-B
DISPLAY TABLES FOR SAARINEN'S TOUR INTERACTIVE
PLAN SECTION
5"
5"
1 1
36"
A
A