Attachment_O_UPDATE-2_Amendment_0008.pdf

PDF 7 MB Posted

Attached to
Arch Museum Exhibits (JEFF 199869B) Federal contract opportunity
Solicitation number
P16PS00660
Issued by
Department of the Interior National Park Service National Office

About this file

Attachment O UPDATE-2_Amendment 0008

View the file

Other files for this federal contract opportunity

Other files attached to Arch Museum Exhibits (JEFF 199869B), newest first.
File Type Posted
Q_and_A_Amendment_0010.pdf PDF
SF30_Amendment_0010.pdf PDF
Q_and_A_Amendment_0009.pdf PDF
Q_and_A_Amendment_0008.pdf PDF
Q_and_A_Amendment_0007.pdf PDF
Q_and_A_Amendment_0006.pdf PDF
Amendment_0006_SF30.pdf PDF
Attachment_C_3_Custom_Elements_Detail_Report_Amendment_0005.pdf PDF
Attachment_F_JEFF_MWE_Custom_Elements_Amendment_0005.pdf PDF
Amendment_0004_to_P16PS00660.pdf PDF
Revised_RFP_Amendment_0004.pdf PDF
9489_(E)_MWE_4811_-_Area_8_Building_The_Arch_-_Display_Table_for_Saarinen's_Tour_Interactive-Arch_D .pdf PDF
9489_(Z)_MWE_1525-Arch_D .pdf PDF
Q_and_A_Amendment_0004.pdf PDF
Vol_II_Submission_Package_P16PS00660_Amendment_0003_.pdf PDF
Attachment-O2__Museum_Drawings_Pt2.pdf PDF
Attachment-O4_Museum_Specification_Vol_1.pdf PDF
Revised_RFP_Amendment_0003.pdf PDF
Attachment-O1_Museum_Drawings_Pt1.pdf PDF
Attachment-O5_Museum_Specification_Vol_2.pdf PDF
Attachment-J_AV_Equip_for_Testing.pdf PDF
Site_Visit_Sign_In_Sheet_08.30.2016.pdf PDF
Attachment_E_Supplementary_Specifications_Amendment_0002.pdf PDF
JEFF_Exhibits_Site_Visit_Presentation.pptx PPTX presentation
Questions_and_Answers_During_Presentation_8.30.16.pdf PDF
Revised_Vol_II_Submission_Package_P16PS00660_Amendment_0001.pdf PDF
Attachment-H_Graphic_Communication.pdf PDF
Attachment-F_Custom_Elements_List.pdf PDF
Attachment-A_NPS_Standard_Exhibit_Specs_Oct2012.pdf PDF
Attachment-D6_JEFF_199869B_Exhibit_Fabrication_Drawings_pg_246-258.pdf PDF
Attachment_W_Wage_Rate_Determination.pdf PDF
Attachment-D3_JEFF_199869B_Exhibit_Fabrication_Drawings_pg_111-150.pdf PDF
Attachment-K_Mock-Up_and_Prototype_Requirements.pdf PDF
Attachment-E_Supplementary_Specifications.pdf PDF
Attachment-B_NPSAccessGuide_V2.1_Feb2012.pdf PDF
Attachment-R_FMSS_ComponentInventorySample.xlsm XLSM spreadsheet
Attachment-D2_JEFF_199869B_Exhibit_Fabrication_Drawings_pg_51-110.pdf PDF
Attachment-D5_JEFF_199869B_Exhibit_Fabrication_Drawings_pg_196-245.pdf PDF
Attachment-N_NPS_Ex_Conserv_Guidelines.pdf PDF
Attachment-U_NPS_EditStyleGuide2015.pdf PDF
Attachment-T_NPS_AVEquipSpecs_12-2013.pdf PDF
Attachment-L_Gov_Furnished_Mtls.pdf PDF
Vol_II_Submission_Package_P16PS00660 .pdf PDF
Attachment-G_Accessioned_Object Layouts.pdf PDF
Attachment-S_FMSS_Inspect_Guide_6-26-09.pdf PDF
Attachment-I_AV_ _IT_Software_Specification.pdf PDF
Vol_I_Submission_Package_P16PS00660.pdf PDF
Attachment-C_2_Exhibit_Elements_Detail_Report.pdf PDF
Attachment-D1_JEFF_199869B_Exhibit_Fabrication_Drawings_pg_1-50.pdf PDF
Attachment-C_1_JEFF_MWE_Database_overview_Report.pdf PDF
Show all 50

Arch Museum Exhibits (JEFF 199869B) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N.T.S.

A 09/20/2016 REVISIONS TO

DRAWINGS

LU

B 09/26/2016 REVISIONS TO

DRAWINGS

LU

AV - AUDIO VISUAL / AUDIO

DC - DISPLAY CASE

PI - PHYSICAL INTERACTIVE

IT - INFORMATION TECHNOLOGY

GL - GRAPHICS LAYOUT

MR - MODEL OR RECONSTRUCTION

INDIVIDUAL PACKAGE TYPES SHOULD BE READ IN

CONJUNCTION WITH THE RELEVANT SPECIFICATIONS

AND LISTS.

SCALES

GL-1-01

Project No.

DRAWING STATUS

Area No.

DWG Type

AUTHOR DATE

RevDWG No.

APPROVED

REV.

BY

NOTESDATEREV.

@ D+

GENERAL DRAWING NOTES

DO NOT SCALE OFF THIS DRAWING

except for the purposes of cost estimating & shop drawing production.

ALL DIMENSIONS TO BE CHECKED ON SITE

ALL DIMENSIONS ARE IN FEET & INCHES

[MILLIMETERS IN SQUARE BRACKETS] UNLESS

OTHERWISE STATED

This drawing shows 'design intent' only.

It is the responsibility of the appointed contractor to finalize development, using specialists approved by Contracting

Officer, & produce detailed shop drawings.

ALL shop drawings to be approved by Contracting Officer prior to manufacture.

All Electrical & data communications systems must conform to the prevailing national regulations & any local bylaws pertaining.

All materials to conform to US national building specification, including fire ratings and spread of flame.

All products specified are for Basis of Design Only. Suitable comparable or similar approved products, may be used.

EXPLANATION OF EXHIBIT CODES

EVERY EXHIBIT ELEMENT IS GIVEN AN IDENTIFICATION

NUMBER OR CODE WHICH UNIQUELY IDENTIFIES IT.

ITEM NUMBER

AREA CODE

EXPLANATION OF PACKAGE TYPE

PACKAGE TYPE

PMIS No. NPS DRAWING No.

M1

EXPLANATION OF DRAWING MARKERS

D1

STANDARD DRAWING NOTE

DETAIL MARKER

FINISHES MARKER REFER TO DRAWING

9489 (Z) MWE 1500

JEFFERSON NATIONAL EXPANSION

MEMORIAL

MUSEUM OF WESTWARD EXPANSION

DRAWING SET NUMBER 366/130323

DRAWING ISSUE REGISTER

RC JULY 15, 2016 RW

- MWE 000 B

BID

Page 2B of 258

A 09/23/16 PUSH BUTTON PAD

REPLACED WITH

ADA KEYPAD

MH

"=1'

FEET

1' 2'

Scale: 3/4" = 1'

4'3'

A

Scale N.T.S.

INTRO TACTILE TABLE

AREA LOCATION

Scale 3/4"=1'

A

INTRO TACTILE TABLE

FRONT ELEVATION

Scale 3/4"=1'

INTRO TACTILE TABLE

PLAN

GL-8-38 A-P

KEY NOTES:

1. OMITTED.

2. TABLETOP SUPPORT.

3. COMPETITION ENTRIES (MR-8-02 A-E). SEE CUSTOM ELEMENTS

FOR DETAILS.

4. GRAPHIC CARCASS

" FIRE RATED FORMALDEHYDE FREE WITH

GRAPHIC PANEL DIGITAL PRINT ON HIGH PRESSURE LAMINATE

INLAY. SEE GRAPHICS LAYOUT LIST FOR ADDITIONAL

SPECIFICATIONS.

5. LED LIGHT TO UNDERSIDE OF TABLE.

6. 46" MONITOR. SEE AV/IT HARDWARE LIST.

7. SEE DRAWING (Q) MWE 1110 FOR WALL CONSTRUCTION.

8. EPOXY HYBRID POWDER COATED END PANELS FIXED BACK TO

METAL STUD UPRIGHTS. END CAPS TO HAVE A SHADOW GAP

AT 6" AFFL WITH 2" RETURN. SEE DRAWING (Q) 1110 MWE FOR

DETAILS.

9. KICKER RETURN AT WALL BASE TO HAVE LED EDGE LIGHTING.

SEE LIGHTING LIST FOR DETAILS.

10. GRAPHIC WALLPAPER BONDED BACK TO CURVED WALL

STRUCTURE. SEE GRAPHICS LAYOUT LIST FOR DETAILS.

11. LED CONTROLLER SUPPLY. ALL POWER TO BE SUPPLIED TO

UNIT TO BE VIA FLOOR BOXES - SEE DRAWING (A) MWE 028 FOR

EXACT LOCATIONS

12. LOCKABLE ACCESS DOOR FOR POWER AND DATA SET WITHIN

WALL.

13. STRUCTURAL COLUMN.

14. DIMENSIONAL LETTERING. SEE GRAPHICS LAYOUT LIST FOR

DETAILS.

15. EDGE LIT GRAPHIC. SEE GRAPHICS LAYOUT LIST.

16. ADA KEYPAD.

NOTES:

FOR TYPICAL ELECTRICAL CONNECTION DETAILS SEE THE (M) DRAWING

SERIES.

ZERO TOLERANCE FOR 27" CLEARANCE FROM FINISHED FLOOR TO

UNDERSIDE OF EXHIBITS.

M1

D6

(Q)1111

GL-8-22

GL-8-06

GL-8-07

MR-8-02 A

MR-8-02 B

MR-8-02 C

IT-8-01

AV-8-04

AV-8-04

IT-8-01

AV-8-02

GL-8-22

GL-8-06

WP1

AV - AUDIO VISUAL / AUDIO

DC - DISPLAY CASE

PI - PHYSICAL INTERACTIVE

IT - INFORMATION TECHNOLOGY

GL - GRAPHICS LAYOUT

MR - MODEL OR RECONSTRUCTION

INDIVIDUAL PACKAGE TYPES SHOULD BE READ IN

CONJUNCTION WITH THE RELEVANT SPECIFICATIONS

AND LISTS.

SCALES

GL-1-01

Project No.

DRAWING STATUS

Area No.

DWG Type

AUTHOR DATE

RevDWG No.

APPROVED

REV.

BY

NOTESDATEREV.

@ D+

GENERAL DRAWING NOTES

DO NOT SCALE OFF THIS DRAWING

except for the purposes of cost estimating & shop drawing production.

ALL DIMENSIONS TO BE CHECKED ON SITE

ALL DIMENSIONS ARE IN FEET & INCHES

[MILLIMETERS IN SQUARE BRACKETS] UNLESS

OTHERWISE STATED

This drawing shows 'design intent' only.

It is the responsibility of the appointed contractor to finalize development, using specialists approved by Contracting

Officer, & produce detailed shop drawings.

ALL shop drawings to be approved by Contracting Officer prior to manufacture.

All Electrical & data communications systems must conform to the prevailing national regulations & any local bylaws pertaining.

All materials to conform to US national building specification, including fire ratings and spread of flame.

All products specified are for Basis of Design Only. Suitable comparable or similar approved products, may be used.

EXPLANATION OF EXHIBIT CODES

EVERY EXHIBIT ELEMENT IS GIVEN AN IDENTIFICATION

NUMBER OR CODE WHICH UNIQUELY IDENTIFIES IT.

ITEM NUMBER

AREA CODE

EXPLANATION OF PACKAGE TYPE

PACKAGE TYPE

PMIS No. NPS DRAWING No.

M1

EXPLANATION OF DRAWING MARKERS

D1

STANDARD DRAWING NOTE

DETAIL MARKER

FINISHES MARKER REFER TO DRAWING

9489 (Z) MWE 1500

JEFFERSON NATIONAL EXPANSION

MEMORIAL

MUSEUM OF WESTWARD EXPANSION

DRAWING SET NUMBER 366/130323

AREA 8 - BUILDING THE ARCH

INTRO TACTILE TABLE

DM JULY 15, 2016 RW

E MWE 4801 A

BID

MR-8-02 D

MR-8-02 E

GL-8-09 A

GL-8-09 B

GL-8-09 C

GL-8-09 D

GL-8-09 E

GL-8-08 A

GL-8-10

DC-8-05

DC-8-05

PI-8-06

Scale N.T.S.

D1

FLIPBOOK EXPLODED ASSEMBLY

PLAN DETAIL D-1

BLOCKING FOR FLIPBOOK

LAST PAGE SECURED TO

TABLETOP

8x

" THICK PAGES

D1

GL-8-07

OBJECT

GL-8-08 B

38 S3

S3

4'-6 1/4"

P14

P14 6

2 2

AV-8-02

/8

A

A

A

Page 127A of 258

FEET

2' 8'4' 6'

Scale: 1/2" = 1'

FEET

1' 4'

Scale: 1" = 1'

2' 3'

A 09/23/16 ADA KEYPAD ADDED MH

AV - AUDIO VISUAL / AUDIO

DC - DISPLAY CASE

PI - PHYSICAL INTERACTIVE

IT - INFORMATION TECHNOLOGY

GL - GRAPHICS LAYOUT

MR - MODEL OR RECONSTRUCTION

INDIVIDUAL PACKAGE TYPES SHOULD BE READ IN

CONJUNCTION WITH THE RELEVANT SPECIFICATIONS

AND LISTS.

SCALES

GL-1-01

Project No.

DRAWING STATUS

Area No.

DWG Type

AUTHOR DATE

RevDWG No.

APPROVED

REV.

BY

NOTESDATEREV.

@ D+

GENERAL DRAWING NOTES

DO NOT SCALE OFF THIS DRAWING

except for the purposes of cost estimating & shop drawing production.

ALL DIMENSIONS TO BE CHECKED ON SITE

ALL DIMENSIONS ARE IN FEET & INCHES

[MILLIMETERS IN SQUARE BRACKETS] UNLESS

OTHERWISE STATED

This drawing shows 'design intent' only.

It is the responsibility of the appointed contractor to finalize development, using specialists approved by Contracting

Officer, & produce detailed shop drawings.

ALL shop drawings to be approved by Contracting Officer prior to manufacture.

All Electrical & data communications systems must conform to the prevailing national regulations & any local bylaws pertaining.

All materials to conform to US national building specification, including fire ratings and spread of flame.

All products specified are for Basis of Design Only. Suitable comparable or similar approved products, may be used.

EXPLANATION OF EXHIBIT CODES

EVERY EXHIBIT ELEMENT IS GIVEN AN IDENTIFICATION

NUMBER OR CODE WHICH UNIQUELY IDENTIFIES IT.

ITEM NUMBER

AREA CODE

EXPLANATION OF PACKAGE TYPE

PACKAGE TYPE

PMIS No. NPS DRAWING No.

M1

EXPLANATION OF DRAWING MARKERS

D1

STANDARD DRAWING NOTE

DETAIL MARKER

FINISHES MARKER REFER TO DRAWING

9489 (Z) MWE 1500

JEFFERSON NATIONAL EXPANSION

MEMORIAL

MUSEUM OF WESTWARD EXPANSION

DRAWING SET NUMBER 366/130323

AREA 9 -TRAM LOBBY AND THE

ARCH

PEOPLE'S FEEDBACK HUB

MH JULY 15, 2016 -

E MWE 4903 A

BID

Scale 1'=1'

C

PEOPLE'S FEEDBACK HUB CENTRAL SUPPORT FRAME

FRONT

VARIES

Scale 1"=1'

B-B

PEOPLE'S FEEDBACK HUB

FRONT SECTION TO SUB CARCASS Scale 1"=1'

C-C

PEOPLE'S FEEDBACK HUB

SIDE SECTION TO ONE ARM

Scale 1/2"=1'

B

PEOPLE'S FEEDBACK HUB

ELEVATION

Scale 1/2"=1'

PEOPLE'S FEEDBACK HUB

PLAN

Scale 3"=1'

D

PEOPLE'S FEEDBACK HUB

ENLARGED SECTION

"2

7'-4 1/2"

Scale 1'=1'

PEOPLE'S FEEDBACK HUB CENTRAL SUPPORT FRAME

PLAN

Scale 1"=1'

A

PEOPLE'S FEEDBACK HUB

FRONT ELEVATION

2'

2'

R

R

KEY NOTES:

1. 22" LED TOUCH SCREEN MONITOR CONNECTED TO PC. 3# IN TOTAL SCREENS AND PC'S - 1# FOR EACH ARM. MACHINE SCREW FIXED TO HINGED MDF BASE BOARD.

2. MANDEX LED DISPLAY TILES - (LEDIT-FLEX) VIDEO TILES - LETTERING SIZE 6". 10# - MAGNETIC MOUNTED TO STEEL SHEET FACING ON CARCASS - COMPLETE WITH

DRIVER AND SENDING BOX AND CONNECTED TO A SEPARATE PC.

3.

" CLEAR ACRYLIC FACE PANEL OVER LED DISPLAY TO PROVIDE PROTECTION.

4.

" STEEL SHEET FACING FINISHED IN POWDER COAT - FORMED OVER MDF CORE PANEL.

5.

" MDF FORMERS CREATING INTERNAL FRAMEWORK.

6. EXTERNAL MDF CLADDING PANELS FINISHED IN CONCRETE EFFECT.

7. ANGLED PANEL IN MDF TO ACCEPT GRAPHIC.

8. LOCKED HINGED FACE PANEL TO ACCESS ELECTRONICS WITHIN.

9. 3"X2" STEEL TUBE FORMING UPRIGHT ELEMENT OF STEEL SUPPORT FRAME.

10.2" STEEL HORIZONTAL RAILS WELDED TO 32X2" STEEL UPRIGHTS FORMING FRAMEWORK.

11.1/4" STEEL PLATE FORMING BASE PLATE WELDED TO STEEL FRAMEWORK. WITH

" DIAMETER HILTI HIT-Z RODS SET IN HY200 EXPOY WITH 2 3/4 EMBEDMENT INTO THE

CONCRETE SLAB.

12.HINGED MDF ACCESS PANEL WITH VENTILATION HOLES & ALLEN HEAD MACHINE SCREW FIXINGS TO TOUCH SCREEN MONITOR.

13.RUBBER TRIM BETWEEN TOUCH SCREEN & STEEL FACE.

14.PC CONNECTED TO TOUCH SCREEN - SIZE TBC.

15.DRIVER AND SENDING BOX CONNECTED TO MANDEX LED DISPLAY PANELS - SIZE TBC.

16.

" CURVED MDF FACE PANEL WITH 1/16" STEEL SHEET FACING BONDED ON TO ACT AS FIXING PANEL FOR MANDEX LED TILES.

17.THE 3# MDF CARCASS STRUCTURES ARE 'S' HOOK FIXED AT THE TOP AND CENTER AND MACHINE SCREW FIXED AT THE BOTTOM TO THE STEEL FRAME FOR

SUPPORT.

18.

" MDF PANEL FORMING BACKING TO STEEL FACE CLADDING.

19.REMOVABLE STEEL TRIM TO ACCESS MANDEX DISPLAY TILES. AFFIXED VIA COUNTERSUNK ALLEN HEAD MACHINE SCREWS FINISHED AS STEEL TRIM INTO FERRULES

SET INTO CARCASS.

20.FLOOR BOX.

21.ADA KEYPAD.

NOTES:

THE ABOVE KEYED NOTES ARE TO BE READ IN CONJUNCTION WITH THE FOLLOWING:

A) THE NPS STANDARD EXHIBIT PLANNING, DESIGN, AND FABRICATION SPECIFICATIONS DATED OCTOBER 2012

B) THE SUPPLEMENTARY SPECIFICATIONS SECTION (DISPLAY CASES AND ASSOCIATED DRESSINGS)

FOR TYPICAL ELECTRICAL CONNECTION DETAILS SEE (M) MWE 912, 915 AND 916.

FOR LOW LEVEL LIGHTING SEE (Z) MWE 1558.

ALL LIGHTING AND ELECTRICAL WORK SHALL BE CARRIED OUT BY A LICENSED ELECTRICAL CONTRACTOR AND COMPLY WITH THE 2014 EDITION OF THE NATIONAL

ELECTRICAL CODE.

A

C.C

2'-6"

1'-3 1/4"

2"

1'-8 5/16"

7 3/16" 7 3/16"

3'-8 5/16"

3'-8 5/16"

2'-3"

1'-5 1/16"

1'-7"

Scale 1"=1'

D-D

PEOPLE'S FEEDBACK HUB

SIDE SECTION TO ONE ARM

D.D

MONITOR HINGED ACCESS PANEL

4 4

2'-3"

5 7/8"

7 7/8"

5 7/8"

6 1/4"

Scale 3"=1'

E-E

PEOPLE'S FEEDBACK HUB

ENLARGED SECTION

B.B

2 3 18

E.E

1"

1"

3/4"

1/16"

6 5/16"

6 5/16"

A

A

A

A

A

IT-9-01

IT-9-01

IT-9-01

IT-9-01

Page 136A of 258

9489 (-) MWE 000 - Drawing Issue Register-Arch D+
Sheets and Views
9489 (-) MWE 000 - Drawing Issue Register-Arch D+
9489 (E) MWE 4801 - Area 8 Building The Arch - Intro Tactile Table-Arch D+
Sheets and Views
9489 (E) MWE 4801 - Area 8 Building The Arch - Intro Tactile Table-Arch D+
9489 (E) MWE 4903 - Area 9 Tram Lobby And The Arch - People's Feed Back Hub-Arch D+
Sheets and Views
9489 (E) MWE 4903 - Area 9 Tram Lobby And The Arch - People's Feed Back Hub-Arch D+

File details come from the government source that posted it. Updated .