ora-grant24-2_Boundary creek_proposed-horizontal-alignment.pdf
PDF 164 KB Posted
- Solicitation number
- 69056723B000021
About this file
This document is a Horizontal Alignment Review Report for the OR FLAP GRANT 24(2), Granite Hill Road Reconstruction, Phase II project. The report provides details on the horizontal alignment of the roadway design, including the alignment name, description, station coordinates, tangential directions and lengths, curve radii, delta angles, degrees of curvature, and other geometric specifications.
The related federal contract opportunity is a solicitation issued by the Department of Transportation Federal Highway Administration for the OR FLAP GRANT 24(2), Granite Hill Road Reconstruction, Phase II project. The solicitation includes the Invitation for Bids (IFB), plans, physical data, and the Construction Contract Administration Document per FAR 36.211. No additional details on response dates, award dates, pricing terms, set asides, incumbents, or key objectives are provided in the given materials.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Horizontal Alignment
Review report for MAIN 01
Boundary Creek
OR FLAP GRANT 24(2)
Granite Hill Road reconstruc on, phase II
Horizontal Alignment Review Report Report Created: Friday, June 21, 2024
Time: 9:42:07 AM
Project: Design IntlFt Description:
File Name: c:\pw-work\d0501462\ora-grant24-2_ALI_COR_Boundary.dgn Last Revised: 6/17/2024 16:52:57
Note: All units in this report are in feet unless specified otherwise.
Alignment Name: BL Alignment Description:
Alignment Style: Alignment\Baseline Station Northing Easting
Element: Linear
START ( START ) 33710.460 415897.042 8754385.908
PC ( PC ) 33929.167 415815.532 8754182.958
Tangential Direction: S68.118°W
Tangential Length: 218.707
Element: Circular
PC ( PC ) 33929.167 415815.532 8754182.958
HPI ( HPI ) 34067.681 415763.910 8754054.423
CC ( CC ) 416205.274 8754026.428
PT ( PT ) 34196.759 415798.879 8753920.396
Radius: 420.000 Delta: 36.505° Right
Degree of Curvature (Arc): 13.642° Length: 267.593
Tangent: 138.514 Chord: 263.089
Middle Ordinate: 21.132 External: 22.251
Back Tangent Direction: S68.118°W Back Radial Direction: N21.882°W
Chord Direction: S86.371°W Ahead Radial Direction: N14.623°E
Ahead Tangent Direction: N75.377°W
Element: Linear
PT ( PT ) 34196.759 415798.879 8753920.396
PC ( PC ) 34417.148 415854.517 8753707.146
Tangential Direction: N75.377°W Tangential Length: 220.388
Page 1 of 2Horizontal Alignment Review Report
6/21/2024
Element: Circular
PC ( PC ) 34417.148 415854.517 8753707.146
HPI ( HPI ) 34514.435 415879.078 8753613.011
CC ( CC ) 415322.333 8753568.295
PT ( PT ) 34609.730 415869.857 8753516.162
Radius: 550.000 Delta: 20.062° Left
Degree of Curvature (Arc): 10.417° Length: 192.582
Tangent: 97.287 Chord: 191.600
Middle Ordinate: 8.408 External: 8.538
Back Tangent Direction: N75.377°W Back Radial Direction: N14.623°E
Chord Direction: N85.408°W Ahead Radial Direction: N5.439°W
Ahead Tangent Direction: S84.561°W
Element: Linear
PT ( PT ) 34609.730 415869.857 8753516.162
END ( END ) 34933.380 415839.179 8753193.969
Tangential Direction: S84.561°W
Tangential Length: 323.650
Page 2 of 2Horizontal Alignment Review Report
6/21/2024
File details come from the government source that posted it. Updated .