1501000 J Facility Management Final 10_07_24.docx
DOCX document 348 KB Posted
- Attached to
- Base Operations Support Contract for Naval Air Station Fallon, Nevada Federal contract opportunity
- Solicitation number
- N62473-23-R-3218
About this file
This document appears to be the Section J Attachments for a Base Operations Support Contract (BOSC) for Naval Air Station Fallon (NASF), Nevada. It includes various attachments that provide definitions, references, facility information, assessment guidance, and other details related to the performance of facility management services at NASF and associated areas.
The key details include: a description of the contract objectives to provide quality facility management services at a fair and reasonable price; the scope covering maintenance, repair, and minor construction for facilities and infrastructure; and the use of a combination of recurring and non-recurring work. The contract will be issued by the Department of the Navy, Naval Facilities Engineering Command. The attachments provide guidance and requirements for inventory, condition assessments, maintenance management, and other facility-related processes that the contractor will be expected to follow.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION J
DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS
TABLE OF CONTENTS
| ATTACHMENT NUMBER |
| ATTACHMENT TITLE |
| J-1501000-01 |
| Definitions and Acronyms |
| J-1501000-02 |
| References and Technical Documents |
| J-1501000-03 |
| Listing of Government Designated Customer Interface Representatives |
| J-1501000-04 |
| Facility Inventory |
| J-1501000-05 |
| Site Maps |
| J-1501000-06 |
| Required Meetings |
| J-1501000-07 |
| Asset Tagging Guidance |
| J-1501000-08 |
| Assets Requiring Condition Assessment N/A |
| J-1501000-09 |
| Meter Group Descriptions and Direct Condition Rating Guidance |
| J-1501000-10 |
| General Direct Condition Rating Guidance |
| J-1501000-11 |
| Historical Data for Project Development Requirements N/A |
| J-1501000-12 |
| Historical Data for Asset Management Services N/A |
| J-1501000-13 |
| Inventory of Technical Library |
| J-1501000-14 |
| Work Classification Monetary Limits |
ATTACHMENT J-1501000-01
DEFINITIONS AND ACRONYMS
| DEFINITION |
| DESCRIPTION |
| Assessment |
| A general term referring to either a survey or inspection of a facility to determine condition. |
| Asset |
| A general term used to refer to an item, such as a component, system, building or facility, that is managed by an automated data management program, e.g., FCAP. |
| Business Management System (BMS) |
| A web-based tool that provides a systematic method for the management of business processes, common practices, and process quality improvements that produce and support the most efficient and effective delivery of NAVFAC’s products and services. |
| CONDITION BASED MAINTENANCE MANAGEMENT |
| A maintenance philosophy that encompasses a condition management cycle that is sustained throughout the entire life-cycle of a facility and its constituent component sections, or assets. |
Defense Readiness Reporting System (DRRS) A DoD system that facilitates the measurement of and reporting on the readiness of the military forces and supporting infrastructure.
| Easement |
| A non-possessory right, or interest, not revocable at will, to use real property of an owner for a limited purpose. |
| Emergency Service Call |
| Service calls shall be classified as “Emergency” when the associated work requires immediate action to correct or prevent loss or damage to Government property and assets, restore disrupted essential services, or eliminate life-threatening hazards to personnel or property. |
| Facility |
| A separate individual building, structure, utility system, or other real property improvement, each item of which is subject to separate reporting and recording. |
| Facility Condition Assessment (FCA) |
| A process for evaluating the condition of shore facilities for programming and budgetary purposes. |
| Facilities Condition Assessment Program (FCAP) |
| A Navy automated data management program that utilizes historical asset lifecycle data and a structured assessment process to evaluate the condition facilities and their components. |
| Facility Investment |
| A Navy Installation Management Accounting Project (IMAP) Core Business Model (CBM) function that consists of sub-functions and activities which provide facility sustainment, restoration and modernization for all Class 1 and Class 2 real property assets. |
| FACILITIES LIFE CYCLE |
| A facilities life cycle is divided into four stages, requirements (planning and design), acquisition (construction and acceptance), stewardship (operations, maintenance and repair), and disposal. |
| FACILITIES MAINTENANCE MANAGEMENT |
| The planning, prioritizing, organizing, controlling, reporting, evaluating, and adjusting of facilities maintenance operations to support the CNO/NAVFAC facilities policy and objectives and satisfy customers’ facility needs. Defined by the International Facility Management Association as “the practice of coordinating the physical workplace with the people and work of the organization.” |
| INFRASTRUCTURE CONDITION ASSESSMENT PROGRAM |
| A foundational component of Condition Based Maintenance Management (CBMM). ICAP comprises three of the four CBMM quadrants: Inventory, Assessment, and Analysis. |
| In-house |
| Performed by Government employees. |
| Inspection |
| A rigorous, detailed assessment of the condition of a facility performed to generate a fundable scope and cost estimate for prioritization and funding of maintenance and repair. |
| Job or Work Order |
| An authorization for work that requires planning and estimating and has an individual line of accounting for financial and performance evaluation. |
| Lease |
| An agreement or contract by which the owner of property grants to another the exclusive rights to possess, use, and enjoy such property for a specified period of time in exchange for consideration. |
| LIFE-CYCLE COSTS |
| A form of economic analysis that considers the total cost of owning, operating, and maintaining a building or system over its useful life. |
| MAXIMO |
| A specially configured software version of MAXIMO®, a commercially available computerized maintenance management system (CMMS), adopted by NAVFAC for enterprise facility asset data management. |
| Military Construction (MILCON) Project |
| A project, as defined in 10 U.S.C. Section 2801, for the construction, development, conversion or extension of any facility carried out with respect to a military installation, e.g., buildings, roads, airfield pavements, or utility systems, having a funded project cost greater than the Special Project limit specified in OPNAVINST 11010.20 Series. |
| PROJECT MINOR |
| Work within Section C that is “ordered” by the Government and may require one or more of the following: planning, engineering, coordination, and multi trades. Can include simple and complex projects. The intent of this work is for upgrade of an obsolete system or component. Project Minor work is FFP not to exceed Contractor liability of $25K in Material, Other Direct Cost and Labor. Work exceeding the Contrractor;s Liability is IDIQ under Spec Item 4 of each Annex. The intent of this work is for upgrade of an obsolete system or component. |
| PROJECT SPECIFIC |
| Work not identified in Section C and is “Ordered” by the Government on an as needed basis and may require one or more of the following: planning, engineering, coordination, and multi trades. Can include simple and complex projects. The intent of this work is to meet customer requirements for services not identified within the scope of Section C. PROJECT SPECIFIC is FFP not to exceed Contractor liability of $25K in Material, Other Direct Cost and Labor. Work exceeding the Contractors Liability is IDIQ under Spec Item 4 of each Annex. |
| REAL PROPERTY |
| Land and improvements to land (i.e., facilities). It includes equipment affixed and built into the facility as an integral part of the facility (such as heating systems), but not movable equipment (e.g., plant equipment, industrial equipment, buoys). |
| RESTORATION |
| Restoration of real property to such a condition that it can be used for its intended purpose. Includes repair or replacement work to restore facilities damaged by inadequate sustainment, excessive age, natural disaster, fire, accident or other causes. |
| R.S. Means |
| A Construction Cost Data method used for Cost Estimating |
| SERVICE ORDER (WORK ORDER) |
| Any work required to return a facility, system, equipment or component to normal working condition. Service orders are minor facility problem requests or requests for facilities-related work that are too small to be planned and estimated. |
| Service work Orders Calls |
| Service calls are received by work reception center from building occupants or designated Government or Contractor representatives; are brief in scope; and do not reasonably require detailed job planning. Multiple maintenance, repair, and minor construction requirements received for the same trade in the same building or structure at the same time will be combined into one service call as long as the service call threshold is not exceeded. Service calls for associated work, which is classified, neither as “Emergency” nor “Urgent” shall be classified as “Routine”. |
| Special Interest Codes (SICs) |
| Under the Facility Investment function, SICs used for funding projects include Sustainment (ST), Restoration and Modernization (RM), New Footprint (NF), and Demolition (DE). |
| Special Project |
| A project for one or more classes of work including repair, construction, maintenance and equipment installation, as defined in OPNAVINST 11010.20, whose funded cost exceeds the regional commander’s approval limits, and, for construction, is below the current MILCON threshold for cost. |
| Specialized Inspection |
| An inspection requiring specialized expertise, e.g., underwater inspection of a pier, |
performed to ascertain structural condition and operational functionality of facilities.
| SUSTAINMENT |
| Maintenance and repair activities necessary to keep a typical inventory of facilities in “normal working condition”. Sustainment includes regularly scheduled maintenance as well as cyclical major repairs or replacement of components that occur periodically over the expected service life of the facilities. |
| UNIFORMAT CLASSIFICATION |
| A standard classification of building components established by the National Institute of Standards and Technology. |
| Acronym |
| Title |
| AICUZ |
| Aircraft Installation Compatibility Use Zone |
| BFR |
| Basic Facility Requirements |
| BMS |
| Business Management System https://portal.navfac.navy.mil/pls/portal/url/page/navfac_bms |
| CBM |
| Core Business Model |
| CBMM |
| Condition Based Maintenance Management |
| CMMS |
| Computerized Maintenance Management System |
| COR |
| Contracting Officer’s Representative |
| DE |
| Demolition |
| DPWO |
| Deputy Public Works Officer |
| DRRS |
| Defense Readiness Reporting System |
| ELINs |
| Exhibit Line Item Numbers |
| EWR |
| Electronic Warfare Radar Ranges |
| FCA |
| Facility Condition Assessment |
| FCAP |
| Facilities Condition Assessment Program |
| FFP |
| Firm Fixed Price |
| FPD |
| Facility Planning Document |
| FRES |
| Facility Readiness Evaluation System |
| FSC |
| Facility Service Contract |
| FSCM |
| Facilities Service Contracts Manager |
| GIS |
| Geospatial Information System |
| ICAP |
| Infrastructure Condition Assessment Program |
| IDIQ |
| Indefinite Delivery Indefinite Quantity |
| IMAP |
| Installation Management Accounting Project |
| IMP |
| Integrated Maintenance Program |
| iNFADS |
| Internet Navy Facilities Assets Data Store |
| IPL |
| Integrated Priority List |
| KO |
| Contracting Officer |
| MAP |
| Maintenance Action Plan |
| MCO |
| Marine Corps Order |
| MDI |
| Mission Dependency Index |
| MILCON |
| Military Construction |
| NASF |
| Naval Air Station Fallon |
| NAVFAC |
| Naval Facilities Engineering Command |
| NF |
| New Footprint |
| PM |
| Preventive Maintenance |
| POAM |
| Plan of Action and Milestones |
| PWD |
| Public Works Department |
| PWIB |
| Pre-work Induction Board |
| PWO |
| Public Works Officer |
| PWS |
| Performance Work Statement |
| RM |
| Restoration and Modernization |
| RSIP |
| Regional Shore Infrastructure Plan |
| SICs |
| Special Interest Codes |
| SPM |
| Single Platform MAXIMO |
| ST |
| Sustainment |
| SWIB |
| Site Work Induction Board |
| ToA |
| Terms of Art |
| TPOC |
| Technical Point of Contact |
| TRC |
| Technical Resource Center |
| UEM |
| Utilities Energy Manager |
| WIB |
| Work Induction Board |
| WIS |
| Work Induction System |
ATTACHMENT J-1501000-02
REFERENCES AND TECHNICAL DOCUMENTS
| Reference |
| Title |
| OPNAVINST 11010.20 |
| Navy Facilities Projects |
| OPNAVINST 11000.16 |
| Command Responsibility for Shore Activity Land and Facilities |
| NAVFACINST 11010.45 |
| Regional Planning Instruction (Site Approval Process) |
| DODD 6055.9 |
| DoD Explosives Safety Management and the DoD Explosives Safety Board |
| UFC 2-000-5N |
| Facility Planning Criteria for Navy/Marine Corps Shore Installations |
| NAVFAC P-78 |
| Real Property Inventory Procedures Manual |
| OPNAVINST 11011.10 |
| Utilization of Navy Real Property |
| SECNAVINST 11011.47 |
| Acquisition, Management, and Disposal of Real Property and Real Property Interests by the Department of the Navy |
J-1501000-03 Listing of Government Designated Customer Interface Representatives
| Command/Activity |
| Facility Description |
| Job Title |
| Telephone |
| NASF Contracting Officer |
| Building 307, PWD |
| KO |
| 775-426-4450 |
| NASF Public Works Officer (PWO) |
| Building 307, PWD |
| PWO |
| 775-426-2712 |
| NASF Deputy Public Works Officer (DPWO) |
| Building 307, PWD |
| DPWO |
| 775-426-2398 |
| Facility Support Contract Manger (FSCM) |
| Building 307, PWD |
| FSCM/COR |
| 775-426-2971 |
| Facility Manager |
| Building 307, PWD |
| FACILITY MANAGER |
| 775-426-2409 |
| Engineering |
| Building 307, PWD |
| PM&EB BRANCH HEAD |
| 775-426-2926 |
| Senior Performance Assessment Representative (SPAR) |
| Building 307, PWD |
| SPAR |
| 775-426-3207 |
ATTACHMENT J-1501000-04
FACILITY INVENTORY
See J-1502000-03 for Inventory
ATTACHMENT J-1501000-05
SITE MAPS
Will be provided after award as a separate attachment
ATTACHMENT J-1501000-06
REQUIRED MEETINGS
| Meeting Title |
| Location |
| Average Duration |
| Frequency |
| Work Induction Board |
| PW Conf Room, \ |
| 1 hour |
| Weekly |
| Outstanding Work Order Status Review |
| PW Conf Room, |
| 2 hours |
| Weekly |
| Customer Project Status Review |
| CO’s Conf Room, |
| 2 hours |
| Monthly |
ATTACHMENT J-1501000-07
ASSET TAGGING GUIDANCE
The Contractor shall label all assets following the format below. All fields indicated align to asset data stored in MAXIMO.
· Asset tagging label must printed on a fade/water resistant material.
· Font must be Times New Roman.
· Font size no less then 18 pt.
· Tag must read, “Asset # XXXXXX”.
ATTACHMENT J-1501000-08
ASSETS REQUIRING CONDITION ASSESSMENT
ATTACHMENT J-1501000-09
METER GROUP DESCRIPTIONS AND DIRECT CONDITION RATING GUIDANCE
B2030410 - Overhead Doors
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-1000- Record the condition of the Controls |
| GREEN: Controls function properly |
AMBER: Controls need calibrating RED: Controls are damaged and/or not operational
| CR-1000- Record the condition of the Door |
| GREEN: Door has minimal damage and corrosion, is square and securely fastened |
AMBER: Door has noticeable damage and corrosion, may be slightly displaced, but does not affect door operation or safety RED: Door has significant damage and/or corrosion, noticeably displaced, and may be structurally unsound or affect door operation
| CR-1000- Record the condition of the Guides |
| GREEN: Guides/Stops/Rollers/Pulleys show no signs of wear or damage, and are properly secured and aligned |
AMBER: Guides/Stops/Rollers/Pulleys show slight wear, and/or may be slightly loose or misaligned RED: Guides/Stops/Rollers/Pulleys have noticeable damage or wear, and are insecurely fastened and/or misaligned
| CR-1000- Record the condition of the Motor |
| GREEN: Motor operates properly, free of excessive noise/vibration, or overheating |
AMBER: Motor exhibits unusual noise/vibration, but still operational, may require maintenance RED: Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
B2030901 - Hangar Doors
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-1000- Record the condition of the Brakes |
| GREEN: Brakes have minimal wear |
AMBER: Brakes have noticeable wear, may exhibit unusual noise, but are still operational RED: Brakes have significant wear, excessive noise, or may not function properly
| CR-1000- Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-1000- Record the condition of the Door |
| GREEN: Door has minimal damage and corrosion, is square and securely fastened |
AMBER: Door has noticeable damage and corrosion, may be slightly displaced, but does not affect door operation or safety RED: Door has significant damage and/or corrosion, noticeably displaced, and may be structurally unsound or affect door operation
| CR-1000- Record the condition of the Guides |
| GREEN: Guides/Stops/Rollers/Pulleys show no signs of wear or damage, and are properly secured and aligned |
AMBER: Guides/Stops/Rollers/Pulleys show slight wear, and/or may be slightly loose or misaligned RED: Guides/Stops/Rollers/Pulleys have noticeable damage or wear, and are insecurely fastened and/or misaligned
| CR-1000- Record the condition of the Motor |
| GREEN: Motor operates properly, free of excessive noise/vibration, or overheating |
RED: Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
D1010110 - Hydraulic Elevators
| Description |
| How to Assess & Enter Meter Value for Condition Rating (CR-1000) |
| Condition |
Notes to Field Assessor:
*Do not select “Green(+)” unless Condition_Date = Install_Date*
· For “GREEN” may assign either G or G(-)
· For “AMBER” may assign any of A(+), A or A(-)
· For “RED” may assign any of R(+), R or R(-)
CR-1000 - Record the condition of the Elevator Assembly
GREEN:
· Car Supporting Platform/Frame has no damage, is structurally sound
· Car Operating Panel/Indicator has minimal damage and corrosion, fully operational
· Car Doors have minimal damage or wear, door operation is smooth
· Controls function properly
· Hydraulic Piston Well has minimal damage, deterioration, no cracks or leaks, fully secured
AMBER:
· Car Supporting Platform/Frame has noticeable damage or corrosion, but no loss of structural integrity
· Car Operating Panel/Indicator has noticeable damage and corrosion, still operational
· Car Doors have noticeable damage or wear, doors are operational but may need adjustments
· Controls need calibrating
· Hydraulic Piston Well has noticeable damage, deterioration, but no cracks or leaks, still operational
RED:
· Car Supporting Platform/Frame has significant damage and corrosion, structural integrity significantly impaired
· Car Operating Panel/Indicator has significant damage and corrosion, operationally impaired
· Car Doors have significant damage or corrosion, doors are operationally impaired
· Controls are damaged and/or not operational
· Hydraulic Piston Well has significant damage, deterioration, cracks or leaks, operationally impaired
D1010140 - Traction Geared Elevators
| Description |
| How to Assess & Enter Meter Value for Condition Rating (CR-1000) |
| Condition |
Notes to Field Assessor:
· For “GREEN” may assign either G or G(-)
| CR-1000 - Record the condition of the Elevator Assembly |
| GREEN: |
· Car Supporting Platform/Frame has no damage, is structurally sound.
· Car Operating Panel/Indicator has minimal damage and corrosion, fully operational.
· Safety Buffers have minimal deterioration or damage, fully operational.
· Motor operates properly, free of excessive noise/vibration, or overheating.
· Anchors/Cables/Tie Backs show no damage, deterioration and corrosion, fully secure.
AMBER:
· Car Supporting Platform/Frame has noticeable damage or corrosion, but no loss of structural integrity.
Car Operating Panel/Indicator has noticeable damage and corrosion, still operational.
· Safety Buffers have noticeable deterioration or damage, still operational
· Car Doors have noticeable damage or wear, doors are operational but may need adjustments.
· Controls need calibrating.
· Motor exhibits unusual noise/vibration, but still operational, may require maintenance.
· Anchors/Cables/Tie Backs show minimal wear or deterioration, but are still fully secure and stable.
RED:
· Car Supporting Platform/Frame has significant damage and corrosion, structural integrity significantly impaired.
· Car Operating Panel/Indicator has significant damage and corrosion, operationally impaired.
· Safety Buffers have significant deterioration or damage, operationally impaired.
· Car Doors have significant damage or corrosion, doors are operationally impaired.
· Controls are damaged and/or not operational.
· Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired.
· Anchors/Cables/Tie Backs have noticeable damage, deterioration and/or corrosion, loosely secured or unstable, may jeopardize safety.
D1010150 - Traction Gearless Elevators
| Description |
| How to Assess & Enter Meter Value for Condition Rating (CR-1000) |
| Condition |
Notes to Field Assessor:
· For “GREEN” may assign either G or G(-)
| CR-1000 - Record the condition of the Elevator Assembly |
| GREEN: |
· Car Supporting Platform/Frame has no damage, is structurally sound.
· Car Operating Panel/Indicator has minimal damage and corrosion, fully operational.
· Safety Buffers have minimal deterioration or damage, fully operational.
· Car Doors have minimal damage or wear, door operation is smooth
· Controls function properly.
· Motor operates properly, free of excessive noise/vibration, or overheating
· Anchors/Cables/Tie Backs show no damage, deterioration and corrosion, fully secure.
AMBER:
· Car Supporting Platform/Frame has noticeable damage or corrosion, but no loss of structural integrity.
Car Operating Panel/Indicator has noticeable damage and corrosion, still operational.
· Safety Buffers have noticeable deterioration or damage, still operational
· Car Doors have noticeable damage or wear, doors are operational but may need adjustments.
· Controls need calibrating.
· Motor exhibits unusual noise/vibration, but still operational, may require maintenance.
· Anchors/Cables/Tie Backs show minimal wear or deterioration, but are still fully secure and stable.
RED:
· Car Supporting Platform/Frame has significant damage and corrosion, structural integrity significantly impaired.
· Car Operating Panel/Indicator has significant damage and corrosion, operationally impaired.
· Safety Buffers have significant deterioration or damage, operationally impaired.
· Car Doors have significant damage or corrosion, doors are operationally impaired.
· Controls are damaged and/or not operational.
· Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired.
· Anchors/Cables/Tie Backs have noticeable damage, deterioration and/or corrosion, loosely secured or unstable, may jeopardize safety.
D1010901 – Lifts
| Description |
| How to Assess & Enter Meter Value for Condition Rating (CR-1000) |
| Condition |
Notes to Field Assessor:
· For “GREEN” may assign either G or G(-)
| CR-1000 - Record the condition of the Lift Assembly |
| GREEN: |
· Controls function properly
· Motor operates properly, free of excessive noise/vibration, or overheating
· Platform has little to no damage or deterioration, and is structurally sound
AMBER:
· Controls need calibrating
· Motor exhibits unusual noise/vibration, but still operational, may require maintenance
· Platform has noticeable damage or deterioration, but still structurally sound
RED:
· Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
· Platform has significant damage or deterioration, may be loose or unstable
D1020110 – Escalators
| Description |
| How to Assess & Enter Meter Value for Condition Rating (CR-1000) |
| Condition |
Notes to Field Assessor:
· For “GREEN” may assign either G or G(-)
| CR-1000 - Record the condition of the Escalator Assembly |
| GREEN: |
· Controls function properly
· Motor operates properly, free of excessive noise/vibration, or overheating
· Handrails have minimal damage or corrosion, and are fully secured
· Platform has little to no damage or deterioration, and is structurally sound
· Step Risers/Tread have minimal damage or deterioration, fully secured and aligned
· Comb Plates have minimal deterioration and damage, and are not loose or displaced
AMBER:
· Controls need calibrating.
· Motor exhibits unusual noise/vibration, but still operational, may require maintenance
· Handrails have noticeable damage or corrosion, slightly loose but still operational
· Platform has noticeable damage or deterioration, but still structurally sound
· Step Risers/Tread have noticeable damage or deterioration, are mostly secure and operational
· Comb Plates have noticeable deterioration and damage, but are not loose or displaced
RED:
· Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
· Comb Plates have significant deterioration and damage, may be noticeably loose, displaced, or misaligned
· Handrails have significant damage or corrosion, noticeable loose or missing
· Platform has significant damage or deterioration, may be loose or unstable
· Step Risers/Tread have significant deterioration, damage, corrosion, or are loose or misaligned
D1090902 - Cranes and Hoists
| Description |
| How to Assess & Enter Meter Value for Condition Rating (CR-1000) |
| Condition |
Notes to Field Assessor:
· For “GREEN” may assign either G or G(-)
| CR-1000 - Record the condition of the Brakes |
| GREEN: |
· Brakes have minimal wear Hook has minimal damage or wear, and is fully secured
· Controls function properly
· Crane Unit shows minimal signs of wear, no loose components, structurally sound, fully operational
· Guide Wheels show little to no wear or damage, are securely fastened, and fully functional
· Motor operates properly, free of excessive noise/vibration, or overheating
· Structural Frame has minimal damage and corrosion, is square and securely fastened
· Trolley Drive has minimal to no damage, operation is smooth, fully functional
| CR-1000 - Record the condition of the Chains/Hooks |
| AMBER: |
· Brakes have noticeable wear, may exhibit unusual noise, but are still operational Hook has noticeable damage or wear, but is still securely fastened Controls need calibrating
· Crane Unit shows noticeable signs of damage or wear, but no loose or missing components, and still operational
· Guide Wheels have noticeable wear, may have slight damage, but are secure and still operational
· Motor exhibits unusual noise/vibration, but still operational, may require maintenance
· Structural Frame has noticeable damage and corrosion, may be slightly displaced, but does not affect door operation or safety
· Trolley Drive has noticeable damage, wear, may require adjustments but is fully functional
| CR-1000 - Record the condition of the Controls |
| RED: |
· Brakes have significant wear, excessive noise, or may not function properly
· Hook has significant damage, connections not secure
· Controls are damaged and/or not operational
· Crane Unit shows significant signs of damage or wear, may have missing or loose components, comprised structural integrity, or is operationally impaired
· Guide Wheels have significant damage, may be loose, displaced, missing, or operationally impaired
· Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
· Structural Frame has significant damage and/or corrosion, noticeably displaced, and may be structurally unsound or affect door operation
· Trolley Drive has significant damage or wear, operation is significantly impaired
D3020130 - Boiler, Cast Iron, Hot Water, Gas
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5060 - Record the condition of the Burner Assembly |
| GREEN: Burners have minimal damage or corrosion, but is fully operational |
AMBER: Burners have noticeable damage or corrosion, flame quality may need adjustment, but still operationally sound RED: Burners have significant damage or corrosion, may be loose or displaced, improper flame, and is not operationally sound
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5365 - Record the condition of the Firebox/Fire Tubes |
| GREEN: Firebox has minimal damage or corrosion |
AMBER: Firebox has noticeable damage or corrosion, but no cracks or holes RED: Firebox has significant damage or corrosion, cracks or holes may be present
| CR-5370 - Record the condition of the Flue |
| GREEN: Flue has minimal damage, is secured and aligned properly, and fully operational |
AMBER: Flue has noticeable damage and corrosion, may be slightly loose or misaligned, but still operational RED: Flue has significant damage and corrosion, noticeably loose, misaligned, or missing, and/or operationally impaired
| CR-5380 - Record the condition of the Fuel System |
| GREEN: Little to no damage or corrosion, secure connections, no leaks, fully operational |
AMBER: Fuel System has noticeable damage or corrosion, but free of leaks, fully operational RED: Fuel System has significant damage or corrosion, significant leaking, and/or is operationally impaired
| CR-5530 - Record the condition of the Piping/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5540 - Record the condition of the Pressure Vessel |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure RED: Tank has noticeable damage, punctures, holes, and leaks, may be unstable or not fully secured
| CR-5690 - Record the condition of the Wiring/Connections |
| GREEN: Wiring is protected/insulated and connections are secure |
AMBER: Wiring is may be frayed but not exposed, connection are generally secure, no noticeable risk of unintentional grounding RED: Wiring is significantly deteriorated or frayed, connection are loose, or risk of unintentional grounding
D3020134 - Boiler, Cast Iron, Steam, Gas
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5060 - Record the condition of the Burner Assembly |
| GREEN: Burners have minimal damage or corrosion, but is fully operational |
AMBER: Burners have noticeable damage or corrosion, flame quality may need adjustment, but still operationally sound RED: Burners have significant damage or corrosion, may be loose or displaced, improper flame, and is not operationally sound
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5365 - Record the condition of the Firebox/Fire Tubes |
| GREEN: Firebox has minimal damage or corrosion |
| CR-5520 - Record the condition of the Pipes/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5540 - Record the condition of the Pressure Vessel |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3020136 - Boiler, Cast Iron, Hot Water, Gas/Oil
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5060 - Record the condition of the Burner Assembly |
| GREEN: Burners have minimal damage or corrosion, but is fully operational |
AMBER: Burners have noticeable damage or corrosion, flame quality may need adjustment, but still operationally sound RED: Burners have significant damage or corrosion, may be loose or displaced, improper flame, and is not operationally sound
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5365 - Record the condition of the Firebox/Fire Tubes |
| GREEN: Firebox has minimal damage or corrosion |
| CR-5380 - Record the condition of the Fuel System |
| GREEN: Little to no damage or corrosion, secure connections, no leaks, fully operational |
RED: Fuel System has significant damage or corrosion, significant leaking, and/or is operationally impaired
| CR-5530 - Record the condition of the Piping/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5540 - Record the condition of the Pressure Vessel |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
| CR-5690 - Record the condition of the Wiring/Connections |
| GREEN: Wiring is protected/insulated and connections are secure |
AMBER: Wiring is may be frayed but not exposed, connection are generally secure, no noticeable risk of unintentional grounding RED: Wiring is significantly deteriorated or frayed, connection are loose, or risk of unintentional grounding
D3020138 - Boiler, Cast Iron, Steam, Gas/Oil
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5060 - Record the condition of the Burner Assembly |
| GREEN: Burners have minimal damage or corrosion, but is fully operational |
AMBER: Burners have noticeable damage or corrosion, flame quality may need adjustment, but still operationally sound RED: Burners have significant damage or corrosion, may be loose or displaced, improper flame, and is not operationally sound
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5345 - Record the condition of the Feed Water System |
| GREEN: Feed Water System has no damage or leaks, fully operational |
AMBER: Feed Water System has noticeable damage or corrosion, may have slight leaks but still operational RED: Feed Water System has significant damage or corrosion, noticeable leaks, and does not function properly
| CR-5365 - Record the condition of the Firebox/Fire Tubes |
| GREEN: Firebox has minimal damage or corrosion |
| CR-5370 - Record the condition of the Flue |
| GREEN: Flue has minimal damage, is secured and aligned properly, and fully operational |
AMBER: Flue has noticeable damage and corrosion, may be slightly loose or misaligned, but still operational RED: Flue has significant damage and corrosion, noticeably loose, misaligned, or missing, and/or operationally impaired
| CR-5530 - Record the condition of the Piping/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5540 - Record the condition of the Pressure Vessel |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3020901 - Boiler, Cast Iron, HW, Oil
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5060 - Record the condition of the Burner Assembly |
| GREEN: Burners have minimal damage or corrosion, but is fully operational |
AMBER: Burners have noticeable damage or corrosion, flame quality may need adjustment, but still operationally sound RED: Burners have significant damage or corrosion, may be loose or displaced, improper flame, and is not operationally sound
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5365 - Record the condition of the Firebox/Fire Tubes |
| GREEN: Firebox has minimal damage or corrosion |
| CR-5370 - Record the condition of the Flue |
| GREEN: Flue has minimal damage, is secured and aligned properly, and fully operational |
AMBER: Flue has noticeable damage and corrosion, may be slightly loose or misaligned, but still operational RED: Flue has significant damage and corrosion, noticeably loose, misaligned, or missing, and/or operationally impaired
| CR-5380 - Record the condition of the Fuel System |
| GREEN: Little to no damage or corrosion, secure connections, no leaks, fully operational |
RED: Fuel System has significant damage or corrosion, significant leaking, and/or is operationally impaired
| CR-5530 - Record the condition of the Piping/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5540 - Record the condition of the Pressure Vessel |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
| CR-5690 - Record the condition of the Wiring/Connections |
| GREEN: Wiring is protected/insulated and connections are secure |
AMBER: Wiring is may be frayed but not exposed, connection are generally secure, no noticeable risk of unintentional grounding RED: Wiring is significantly deteriorated or frayed, connection are loose, or risk of unintentional grounding
D3020902 - Boiler, Cast Iron, Steam, Oil
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5060 - Record the condition of the Burner Assembly |
| GREEN: Burners have minimal damage or corrosion, but is fully operational |
AMBER: Burners have noticeable damage or corrosion, flame quality may need adjustment, but still operationally sound RED: Burners have significant damage or corrosion, may be loose or displaced, improper flame, and is not operationally sound
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5365 - Record the condition of the Firebox/Fire Tubes |
| GREEN: Firebox has minimal damage or corrosion |
| CR-5520 - Record the condition of the Pipes/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5540 - Record the condition of the Pressure Vessel |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3030130 - Chiller, Reciprocating, Water Cooled
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5140 - Record the condition of the Compressor |
| GREEN: No excessive noise, vibration, or overheating from compressor, little to no damage and fully operational |
AMBER: Excessive Noise, Vibration, or overheating noticeable from compressor, but compressor is still functional RED: Unacceptable Noise, Vibration, or overheating from compressor, significant damage, and/or operationally impaired
| CR-5155 - Record the condition of the Condenser |
| GREEN: Minimal corrosion or fouling of the condenser/coils, no damage |
AMBER: Minimal to noticeable signs of corrosion on coils, or coils are clogged, still operational RED: Significant damage, corrosion or fouling of the condenser/coils, no damage, operationally impaired
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5295 - Record the condition of the Enclosure |
| GREEN: Minimal damage and corrosion on Enclosure, fully secured |
AMBER: Noticeable damage/corrosion to Enclosure, Panels may be slightly detached, loose or displaced RED: Significant damage/corrosion to Enclosure, a number of panels are loose, displaced, or missing
| CR-5305 - Record the condition of the Evaporator |
| GREEN: Minimal corrosion or fouling of the evaporator/coils, no damage |
RED: Significant damage, corrosion or fouling of the evaporator/coils, operationally impaired
| CR-5530 - Record the condition of the Piping/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5565 - Record the condition of the Receiver Tank |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3030135 - Chiller, Reciprocating, Air Cooled
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5140 - Record the condition of the Compressor |
| GREEN: No excessive noise, vibration, or overheating from compressor, little to no damage and fully operational |
AMBER: Excessive Noise, Vibration, or overheating noticeable from compressor, but compressor is still functional RED: Unacceptable Noise, Vibration, or overheating from compressor, significant damage, and/or operationally impaired
| CR-5155 - Record the condition of the Condenser |
| GREEN: Minimal corrosion or fouling of the condenser/coils, no damage |
RED: Significant damage, corrosion or fouling of the condenser/coils, no damage, operationally impaired
| CR-5175 - Record the condition of the Condenser Fan(s) Assembly |
| GREEN: Motor operates properly, free of excessive noise/vibration, or overheating |
RED: Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5295 - Record the condition of the Enclosure |
| GREEN: Minimal damage and corrosion on Enclosure, fully secured |
| CR-5305 - Record the condition of the Evaporator |
| GREEN: Minimal corrosion or fouling of the evaporator/coils, no damage |
| CR-5520 - Record the condition of the Pipes/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5565 - Record the condition of the Receiver Tank |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
| CR-5690 - Record the condition of the Wiring/Connections |
| GREEN: Wiring is protected/insulated and connections are secure |
AMBER: Wiring is may be frayed but not exposed, connection are generally secure, no noticeable risk of unintentional grounding RED: Wiring is significantly deteriorated or frayed, connection are loose, or risk of unintentional grounding
D3030140 - Chiller, Centrifugal, Water Cooled
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5110 - Record the condition of the Centrifugal Motor |
| GREEN: Motor operates properly, free of excessive noise/vibration, or overheating |
RED: Motor exhibits excessive noise/vibration, overheating, and/or operation is significantly impaired
| CR-5140 - Record the condition of the Compressor |
| GREEN: No excessive noise, vibration, or overheating from compressor, little to no damage and fully operational |
AMBER: Excessive Noise, Vibration, or overheating noticeable from compressor, but compressor is still functional RED: Unacceptable Noise, Vibration, or overheating from compressor, significant damage, and/or operationally impaired
| CR-5155 - Record the condition of the Condenser |
| GREEN: Minimal corrosion or fouling of the condenser/coils, no damage |
RED: Significant damage, corrosion or fouling of the condenser/coils, no damage, operationally impaired
| CR-5210 - Record the condition of the Controls/Sensors |
| GREEN: Controls function properly |
| CR-5295 - Record the condition of the Enclosure |
| GREEN: Minimal damage and corrosion on Enclosure, fully secured |
| CR-5305 - Record the condition of the Evaporator |
| GREEN: Minimal corrosion or fouling of the evaporator/coils, no damage |
| CR-5530 - Record the condition of the Piping/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5565 - Record the condition of the Receiver Tank |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3030145 - Chiller, Gas Absorption, Water Cooled
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5000 - Record the condition of the Absorber |
| GREEN: Absorber has minimal damage and corrosion, but no leaks |
AMBER: Absorber has noticeable damage and corrosion, but minimal leaks and is still operational RED: Absorber has significant damage and corrosion, and noticeable leaks, operationally impaired
| CR-5140 - Record the condition of the Compressor |
| GREEN: No excessive noise, vibration, or overheating from compressor, little to no damage and fully operational |
AMBER: Excessive Noise, Vibration, or overheating noticeable from compressor, but compressor is still functional RED: Unacceptable Noise, Vibration, or overheating from compressor, significant damage, and/or operationally impaired
| CR-5155 - Record the condition of the Condenser |
| GREEN: Minimal corrosion or fouling of the condenser/coils, no damage |
RED: Significant damage, corrosion or fouling of the condenser/coils, no damage, operationally impaired
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5295 - Record the condition of the Enclosure |
| GREEN: Minimal damage and corrosion on Enclosure, fully secured |
| CR-5305 - Record the condition of the Evaporator |
| GREEN: Minimal corrosion or fouling of the evaporator/coils, no damage |
| CR-5430 - Record the condition of the Heat Generator |
| GREEN: Heating Element has little to no damage or corrosion, and is fully operational |
AMBER: Heating Element has noticeable damage or corrosion, but still operational RED: Heating Element has significant damage or corrosion, operationally impaired
| CR-5520 - Record the condition of the Pipes/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5555 - Record the condition of the Receiver |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3030150 - Chiller, Steam Absorption, Water Cooled
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5000 - Record the condition of the Absorber |
| GREEN: Absorber has minimal damage and corrosion, but no leaks |
AMBER: Absorber has noticeable damage and corrosion, but minimal leaks and is still operational RED: Absorber has significant damage and corrosion, and noticeable leaks, operationally impaired
| CR-5140 - Record the condition of the Compressor |
| GREEN: No excessive noise, vibration, or overheating from compressor, little to no damage and fully operational |
AMBER: Excessive Noise, Vibration, or overheating noticeable from compressor, but compressor is still functional RED: Unacceptable Noise, Vibration, or overheating from compressor, significant damage, and/or operationally impaired
| CR-5155 - Record the condition of the Condenser |
| GREEN: Minimal corrosion or fouling of the condenser/coils, no damage |
RED: Significant damage, corrosion or fouling of the condenser/coils, no damage, operationally impaired
| CR-5200 - Record the condition of the Controls |
| GREEN: Controls function properly |
| CR-5295 - Record the condition of the Enclosure |
| GREEN: Minimal damage and corrosion on Enclosure, fully secured |
| CR-5305 - Record the condition of the Evaporator |
| GREEN: Minimal corrosion or fouling of the evaporator/coils, no damage |
| CR-5430 - Record the condition of the Heat Generator |
| GREEN: Heating Element has little to no damage or corrosion, and is fully operational |
AMBER: Heating Element has noticeable damage or corrosion, but still operational RED: Heating Element has significant damage or corrosion, operationally impaired
| CR-5520 - Record the condition of the Pipes/Fittings/Valves |
| GREEN: Piping/fittings free of leaks, all connections are tight, valves operate properly, insulation is in place, minimal corrosion |
AMBER: Piping/Fittings show noticeable signs of corrosion, missing or damaged insulation, but connections are tight and no leaking RED: Piping/Fittings are damaged and leaking, valves are not functioning, significant internal scale and corrosion may lead to clogs
| CR-5555 - Record the condition of the Receiver |
| GREEN: Tank has little to no damage or corrosion, no leaks, insulation is intact where applicable, stable and secure |
AMBER: Tank has some damage or corrosion, insulation may be mission, very minor leaks may be present, but overall holds its contents, is stable and secure
D3030310 - Cooling Tower, Galvanized
| Meter & Description |
| Direct Condition Rating Guidance |
| Condition |
| CR-5025 - Record the condition of the Basin/Sump |
| GREEN: Sump has minimal damage or corrosion, no leaking |
AMBER: Sump has noticeable damage or corrosion, but no leaking RED: Sump has significant damage or corrosion, and noticeable leaking, operationally impaired
| CR-5280 - Record the condition of the Electrodes |
| GREEN: Conductivity Electrodes have minimal damage and corrosion, secure connections and fully functional |
AMBER: Conductivity Electrodes have noticeable damage and corrosion, some loose connections but still functional RED: Conductivity Electrodes have significant damage and corrosion, loose or missing connections, operationally impaired
| CR-5325 - Record the condition of the Fan Assembly |
| GREEN: Fan blades are in balance and free of damage or corrosion |
AMBER: Excessive Noise/Vibration, but blades not bent or corroded, fully operational RED: Fans blades are out of balance, significantly bent or corroded, or fan is operationally impaired