Amendment 0003 Revised P1360 DWGS.pdf

PDF 21 MB Posted

Attached to
P1360: Joint Maritime Facility, Newfoundland, Canada
Solicitation number
N6247026R0011
Issued by

About this file

This document is Amendment 002 to the Joint Maritime Facility (P1360) contract, dated March 27, 2026, issued by Naval Facilities Engineering Systems Command Atlantic for the Department of the Navy. The amendment modifies the original architectural and engineering design drawings and specifications for a new maritime facility construction project.

The amendment revises multiple design sheets across all disciplines including structural (S-001 through S-504), architectural (A-001 through A-606), civil/site (C-101 through CU-202), landscape (L-001 and LS-101 through LS-501), fire protection (F-001, FA-101, FK-101, FX-101, FX-401), plumbing (P-102, P-104), mechanical HVAC (M-101, M-502), and electrical (EL-101, EP-101 through EP-607, EG-101, TN-101, TY-101). Key revisions include updated slab locations and keynotes on foundation plans, revised wall sections and details, modified electrical panel schedules and power distributions, and relocated clean agent suppression equipment. The facility includes operational areas with raised access floors, multiple pump rooms, mechanical and electrical equipment spaces, fire suppression and alarm systems, backup power generation (750 kW generators), uninterruptible power supplies (UPS A and B at 400 kW each), HVAC systems with chilled water loops, and comprehensive security and telecommunications infrastructure. The design incorporates precast concrete walls, structural steel framing, metal deck roofing, and extensive utility distribution systems throughout the approximately 4,300 square meter facility. All work must comply with Canadian standards and codes including CSA specifications for structural design, concrete construction, and electrical installations.

View the file

Other files

File Type Posted
N6247026R00110005 SF 30.pdf PDF
Attachment K _Moll Point Joint Maritime Facility NL Tech Memo.pdf PDF
AMENDMENT 0005.pdf PDF
Solicitation Amendment N6247026R00110005 SF 30.pdf PDF
Attachment J _ Hazardous Materials Report_2024_Appendix D of SEI.pdf PDF
P1360-Drawings- Amendment 0005.pdf PDF
N6247026R0011 Amendment 0004.pdf PDF
P1360 Site Visit Attendance Log.pdf PDF
AMENDMENT 0003.pdf PDF
Amendment 0003 Revised P1360 Specifications.pdf PDF
N6247026R0011 Amendment 0003.pdf PDF
Amendment 0003 Revised P1360 Demo-DWGS.pdf PDF
Amendment N6247026R0008 0005.pdf PDF
Solicitation Amendment N6247026R0011 (0002).pdf PDF
Solicitation Amendment N6247026R00110001 (0001).pdf PDF
Attachment C - Past Performance Questionnaire (PPQ).pdf PDF
Attachment F_P1360 DWG_Part 1 of 12.pdf PDF
Attachment F_P1360 DWG_Part 5 of 12.pdf PDF
Attachment F_P1360 DWG_Part 7 of 12.pdf PDF
Attachment G - Representations and Certifications.pdf PDF
Attachment E_P1360 SPECS_Part 1 of 5.pdf PDF
Attachment E_P1360 SPECS_Part 3 of 5.pdf PDF
Attachment F_P1360 DWG_Part 9 of 12.pdf PDF
Attachment F_P1360 DWG_Part 12 of 12.pdf PDF
Solicitation - N6247026R0011.pdf PDF
Attachment E_P1360 SPECS_Part 4 of 5.pdf PDF
Attachment E_P1360 SPECS_Part 5 of 5.pdf PDF
Attachment F_P1360 DWG_Part 3 of 12.pdf PDF
Attachment F_P1360 DWG_Part 4 of 12.pdf PDF
Attachment F_P1360 DWG_Part 6 of 12.pdf PDF
Attachment F_P1360 DWG_Part 11 of 12.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xlsx XLSX spreadsheet
Attachment B - Construction Experience Project Data Sheet.pdf PDF
Attachment D - Schedule B Price Proposal Form.pdf PDF
Attachment E_P1360 SPECS_Part 2 of 5.pdf PDF
Attachment F_P1360 DWG_Part 2 of 12.pdf PDF
Attachment F_P1360 DWG_Part 8 of 12.pdf PDF
Attachment F_P1360 DWG_Part 10 of 12.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G-001

P1360 JOINT MARITIME FACILITY

AMENDMENT 002

27 March 2026

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

G-002

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

NAVFAC

DWG NO. SHEET NO. SHEET TITLE

GENERAL

1 14157063 G-001 COVER SHEET

2 14157064 G-002 INDEX OF DRAWING

3 14157065 G-007 CODE COMPLIANCE SUMMARY

4 14157066 G-008 BUILDING CODE SITE PLAN

5 14157067 G-101 LIFE SAFETY PLAN

6 14157068 G-201 AIR BARRIER SYSTEM KEY PLAN

7 14157069 G-202 AIR BARRIER SYSTEM BUILDING SECTIONS

GEOTECHNICAL

8 14157070 B-001 NOTES AND LEGEND

9 14157071 B-101 SUBSURFACE EXPLORATION LOCATION PLAN

10 14157072 B-201 FOOTING UNDERCUT EXCAVATION

11 14157073 B-601 SUBSURFACE EXPLORATION RECORDS

12 14157074 B-602 SUBSURFACE EXPLORATION RECORDS

13 14157075 B-603 SUBSURFACE EXPLORATION RECORDS

14 14157076 B-604 SUBSURFACE EXPLORATION RECORDS

15 14157077 B-605 SUBSURFACE EXPLORATION RECORDS

16 14157078 B-606 SUBSURFACE EXPLORATION RECORDS

17 14157079 B-607 SUBSURFACE EXPLORATION RECORDS

CIVIL

18 14157080 C-001 LEGEND, NOTES & ABBREVIATIONS

19 14157081 C-002 CIVIL NOTES

20 14157082 VF101 EXISTING CONDITIONS PLAN

21 14157083 CE101 EROSION AND SEDIMENT CONTROL PLAN PHASE I

22 14157084 CE102 EROSION AND SEDIMENT CONTROL PLAN PHASE II

23 14157085 CS101 CIVIL SITE AND LAYOUT PLAN

24 14157086 CS401 CONCRETE JOINTING PLAN

25 14157087 CG101 GRADING PLAN

26 14157088 CU101 UTILITY PLAN

27 14157089 CU201 STORM SEWER AND WATER LINE PROFILES

28 14157090 CU202 STORM SEWER PROFILES

29 14157091 C-501 DETAILS - EROSION AND SEDIMENT CONTROL

30 14157092 C-502 DETAILS - EROSION AND SEDIMENT CONTROL

31 14157093 C-503 DETAILS - SITE

32 14157094 C-504 DETAILS - SITE

33 14157095 C-505 DETAILS - UTILITY

34 14157096 C-506 DETAILS - UTILITY

35 14157097 C-507 DETAILS - UTILITY

36 14157098 C-508 DETAILS - UTILITY

37 14157099 C-509 DETAILS - UTILITY

38 14157100 C-510 DETAILS - FENCING

39 14157101 C-511 DETAILS - FENCING

LANDSCAPE

40 14157102 L-001 LANDSCAPE NOTES, LEGEND, AND ABBREVIATIONS

41 14157103 LS101 LANDSCAPE SITE PLAN

42 14157104 LS501 LANDSCAPE DETAILS

STRUCTURAL

43 14157105 S-001 GENERAL STRUCTURAL NOTES

44 14157106 S-002 LEGENDS AND ABBREVIATIONS

45 14157107 S-003 LOADING DIAGRAMS

46 14157108 S-101 FOUNDATION PLAN

47 14157109 S-102 LOW ROOF FRAMING PLAN

48 14157110 S-103 HIGH ROOF FRAMING PLAN

49 14157111 S-301 SECTIONS

50 14157112 S-302 SECTIONS

51 14157113 S-401 FUEL TANK ROOM FRAMING PLAN

52 14157114 S-501 FOUNDATION DETAILS

53 14157115 S-502 SOG DETAILS

54 14157116 S-503 STEEL DETAILS

55 14157117 S-504 WALL DETAILS

ARCHITECTURAL

56 14157118 A-001 GENERAL NOTES LEGENDS AND ABBREVIATIONS

57 14157119 A-101 WORK KEYNOTES - PLANS

58 14157120 A-105 FLOOR PLAN

59 14157121 A-106 REFLECTED CEILING PLAN

60 14157122 A-107 ROOF PLAN

61 14157123 A-201 WORK KEYNOTES - ELEVATIONS

62 14157124 A-205 ELEVATIONS

63 14157125 A-206 ELEVATIONS

64 14157126 A-301 WORK KEYNOTES - BUILDING SECTIONS

65 14157127 A-302 WORK KEYNOTES WALL - SECTIONS

66 14157128 A-305 BUILDING SECTIONS

67 14157129 A-306 WALL SECTIONS

68 14157130 A-307 WALL SECTIONS

69 14157131 A-401 KEYNOTES - ENLARGED PLAN & INTERIOR ELEVATIONS

70 14157132 A-405 ENLARGED FLOOR PLANS

71 14157133 A-406 INTERIOR ELEVATIONS AND TOILET ACCESSORIES SCHEDULES

72 14157134 A-407 CASEWORK SECTIONS

73 14157135 A-501 WORK KEYNOTES - EXTERIOR DETAILS

74 14157136 A-502 WORK KEYNOTES CEILING, PENETRATION, FIRE RATED PARTITION AND RAISED ACCESS FLOOR DETAILS

75 14157137 A-505 ROOF DETAILS

76 14157138 A-506 EXTERIOR DETAILS

77 14157139 A-507 CEILING DETAILS

78 14157140 A-508 FIRE RATED PENETRATION DETAILS

79 14157141 A-509 FIRE RATED PARTITION DETAILS

80 14157142 A-510 RAISED ACCESS FLOOR DETAILS

81 14157143 A-601 WORK KEYNOTES - DOORS, LOUVERS, TRANS. PANEL DETAILS

82 14157144 A-605 PARTITION TYPES

83 14157145 A-606 DOOR AND WINDOW SCHEDULES AND TYPES

84 14157146 A-607 DOOR DETAILS

85 14157147 A-608 PIPE PENETRATION AND LOUVER DETAILS

INTERIORS

86 14157148 IF101 INTERIOR FURNITURE PLAN

87 14157149 IF601 FURNITURE SCHEDULE AND DETAILS

88 14157150 IG101 INTERIOR SIGNAGE PLAN

89 14157151 IG601 INTERIOR SIGNAGE SCHEDULE AND DETAILS

90 14157152 IN601 INTERIOR FINISH LEGEND AND SCHEDULE

FIRE PROTECTION

91 14157153 F-001 FIRE PROTECTION LEGEND AND NOTES

92 14157154 F-002 FIRE PROTECTION NOTES CONTINUED

93 14157155 FA101 FIRE ALARM FLOOR PLAN

94 14157156 FA501 FIRE ALARM DETAILS

95 14157157 FA502 FIRE ALARM RISER DIAGRAM AND MATRIX

96 14157158 FX101 FIRE SUPRESSION FLOOR PLAN

97 14157159 FX401 FIRE PUMP PLAN VIEW

98 14157160 FK101 CLEAN AGENT SUPRESSION FLOOR PLAN

99 14157161 FK501 CLEAN AGENT RISER DIAGRAM AND MATRIX

PLUMBING

100 14157162 P-001 GENERAL NOTES, SYMBOLS, AND LEGENDS

101 14157163 P-101 DOMESTIC WATER - FLOOR PLAN

102 14157164 P-102 SANITARY/VENT - FLOOR PLAN

103 14157165 P-103 RADON - FLOOR PLAN

104 14157166 P-104 FUEL LINE - FLOOR PLAN

105 14157167 P-401 ENLARGED FLOOR PLANS

106 14157168 P-501 PLUMBING DETAILS

107 14157169 P-502 PLUMBING DETAILS

108 14157170 P-601 PLUMBING SCHEDULES

109 14157171 P-602 PLUMBING SCHEDULES

110 14157172 P-701 WATER RISER DIAGRAM

111 14157173 P-702 WATER RISER DIAGRAM

112 14157174 P-703 RADON MITIGATION RISER DIAGRAM

113 14157175 P-704 FUEL - OIL SCHEMATICS

MECHANICAL

114 14157176 M-001 MECHANICAL GENERAL NOTES, SYMBOLS, AND LEGENDS

115 14157177 M-101 FLOOR PLAN - MECHANICAL HVAC

116 14157178 M-102 FLOOR PLAN - MECHANICAL PIPING

117 14157179 M-401 ENLARGED FLOOR PLAN - MECHANICAL ROOM DUCTWORK

118 14157180 M-402 ENLARGED FLOOR PLAN - MECHANICAL ROOM PIPPING

119 14157181 M-403 MECHANICAL SECTION PLANS

120 14157182 M-501 MECHANICAL DETAILS

121 14157183 M-502 MECHANICAL DETAILS

122 14157184 M-503 MECHANICAL DETAILS

123 14157185 M-504 MECHANICAL DETAILS

124 14157186 M-505 MECHANICAL DETAILS

125 14157187 M-506 MECHANICAL DETAILS

126 14157188 M-507 MECHANICAL DETAILS

127 14157189 M-601 MECHANICAL SCHEDULES

128 14157190 M-602 MECHANICAL SCHEDULES

129 14157191 M-603 MECHANICAL SCHEDULES

130 14157192 M-701 MECHANIAL CONTROLS

131 14157193 M-702 CHILLED WATER CONTROL

132 14157194 M-703 MECHANICAL CONTROLS

133 14157195 M-704 MECHANICAL CONTROLS

134 14157196 M-705 MECHANICAL CONTROLS

ELECTRICAL

135 14157197 E-001 ELECTRICAL LEGEND AND ABBREVIATIONS

136 14157198 ES101 ELECTRICAL DEMOLITION SITE PLAN

137 14157199 ES102 ELECTRICAL SITE PLAN

138 14157200 ES501 ELECTRICAL SITE DETAILS

139 14157201 ES502 ELECTRICAL SITE DETAILS

140 14157202 ES503 OVERHEAD ELECTRICAL SITE DETAILS

141 14157203 ES504 OVERHEAD ELECTRICAL SITE DETAILS

142 14157204 EL101 ELECTRICAL LIGHTING PLAN

143 14157205 EL501 LUMINAIRE DETAILS

144 14157206 EL502 LUMINAIRE DETAILS

145 14157207 EL601 LUMINAIRE SCHEDULE AND CONTROL TABLE

146 14157208 EP101 ELECTRICAL POWER PLAN

147 14157209 EP102 ELECTRICAL POWER PLAN - MECHANICAL EQUIPMENT

148 14157210 EP201 ELECTRICAL SWITCHBOARD GS1 ELEVATION AND SCHEDULE

149 14157211 EP202 ELECTRICAL SWITCHBOARD ES1 ELEVATION AND SCHEDULE

150 14157212 EP601 ELECTRICAL ONE-LINE DIAGRAM

151 14157213 EP602 ELECTRICAL PANELBOARD SCHEDULES

152 14157214 EP603 ELECTRICAL PANELBOARD SCHEDULES

153 14157215 EP604 PDU-1A PANELBOARD SCHEDULES

154 14157216 EP605 PDU-2A AND PDU-AB PANELBOARDS SCHEDULES

155 14157217 EP606 PDU-1B PANELBOARD SCHEDULES

156 14157218 EP607 PDU-2B AND GL115 PANELBOARD SCHEDULES

157 14157219 EG101 ELECTRICAL GROUNDING PLAN

158 14157220 EG102 LIGHTNING PROTECTION SYSTEM ROOF PLAN

159 14157221 EG201 EXTERIOR LPS ELEVATIONS

160 14157222 EG202 EXTERIOR LPS ELEVATIONS

161 14157223 EG501 GROUNDING AND LPS DETAILS

162 14157224 EG502 GROUNDING AND LPS DETAILS

163 14157225 TN101 TELECOMMUNICATIONS AND OVERHEAD CABLE TRAY PLAN

164 14157226 TN401 ENLARGED TELECOMMUNICATIONS PLANS

165 14157227 TN501 TELECOMMUNICATIONS WORKSTATION OUTLET DETAILS

166 14157228 TN601 TELECOMMUNICATIONS RISER DIAGRAMS

167 14157229 TY101 ELECTRONIC SECURITY SYSTEM PLAN

168 14157230 TY501 ELECTRONIC SECURITY SYSTEM DOOR ELEVATIONS

169 14157231 TY601 ACCESS CONTROL AND INTRUSION DETECTION SYSTEM RISER DIAGRAMS

170 14157232 TY602 VIDEO SURVEILLANCE SYSTEM RISER DIAGRAM

GRAPHIC SCALE

G-101

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

A1 LIFE SAFETY FLOOR PLAN

GENERAL SHEET NOTES

uuu

S u

MEANS OF EGRESS

LEGEND

GENERAL SHEET NOTES

SHEET KEYNOTES

uuuu u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u uuu uuu uuu uuu u u u u u u u u u u u u u u u u u u

S S S S S

S S

S

S S

S

SSS

S S

S

SSSSS

S S

S S

S S

S S

S

S S S S S S S S S S S

S S u u u u u u u u u u u u u

E

TR

E

E

C

C

S

C C

C C

C

C C

E

E

E

C

C

C

C

C

C

C

CS101

SITE PLAN

GENERAL NOTES

GRAPHIC SCALE

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

CONSTRUCTION KEYNOTES

TR

CS401

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

CJOINT LEGEND

GENERAL NOTES

CONCRETE SIDEWALK AND HEAVY DUTY PCCA1

CONCRETE SIDEWALKD1

PLAN

NORTH

PLAN

NORTH

DOOR PADS ON SOUTH SIDE OF BUILDINGB2

PLAN

NORTH

GRAPHIC SCALE

?href ?href ?href ?href ?href

C

C

C

C

D5 C-505E

E

TR

E

E

C

C

C

D

S

C C

C C

C

C C

D D

D

E

E

E

C

GRADING PLAN

CG101

GRAPHIC SCALE

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

GENERAL NOTES

TR

E

E

C

C

C

D

S

C C

C C

C

C C

D D

D

E

E

E

C

C

C

C

C

C

C

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

UTILITY PLAN

GRAPHIC SCALE

GENERAL NOTES

CONSTRUCTION KEYNOTES

UTILITY PLAN

CU101

(CONTINUED)

SCALE:

200 WATER LINE "A"A3 1 = 30 VERTICAL

1 = 300 HORIZONTAL

SCALE:

200 WATER LINE "B"A5 1 = 30 VERTICAL

1 = 300 HORIZONTAL

SCALE:

STORM PROFILE "A"C5 1 = 30 VERTICAL

1 = 300 HORIZONTALSCALE:

STORM PROFILE "B"C3 1 = 30 VERTICAL

1 = 300 HORIZONTAL

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

CU201

SCALE:

STORM PROFILE "C"C5 1 = 30 VERTICAL

1 = 300 HORIZONTAL

SCALE:

STORM PROFILE "D"A2 1 = 30 VERTICAL

1 = 300 HORIZONTAL SCALE:

STORM PROFILE "E"A4 1 = 30 VERTICAL

1 = 300 HORIZONTAL

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

CU202

C-504

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

B1 ASPHALT PAVEMENT

C3

THICKENED EDGE EXPANSION JOINT (TEJ)

A4 REINFORCED SLAB R

B3 CONTRACTION JOINT (CJ)

A2

TRANSITION - ASPHALT TO CONCRETE SECTION (TEB)

A1 THICKENED EDGE (TE)

C1 HEAVY DUTY PORTLAND CEMENT CONCRETE (PCC)

?href ?href ?href ?href ?href ?href ?href ?href ?href ?href ?href ?href

C-509

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

ALARM DEVICE

A1 WASTEWATER HOLDING TANK

C3 CULVERT SECURITY GRILL

?href ?href

C-510

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

C4 GROUND ROD CONNECTION DETAIL

A4

SECTION (TYP)

GATE PLAN

A1

A1 TYPICAL SINGLE CANTILEVERED SLIDING GATE ELEVATION- (4) BAYS SHOWN A4

C1

GROUNDING DETAILB4

?href ?href ?href ?href ?href ?href ?href ?href

L-001

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

MATERIALS LEGEND

GENERAL NOTES

NAME

A1

DETAIL, SECTION,

ELEVATION TITLE

NAME

PLAN TITLE AND

NORTH ARROW

DETAIL /

ENLARGED PLAN

EXTERIOR

ELEVATION

DETAIL /

WALL SECTION

A1

A1

A1

LANDSCAPE ARCHITECTURAL SYMBOLOGY ABBREVIATIONS

TR

E

E

C

C

D

S

C C

C C

C

C C

D D

D

E

E

E

C

S S

S S S S

S

C

C

C

C

C

GRAPHIC SCALE

LS101

GENERAL SHEET NOTES

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

PLAN

NORTH

LANDSCAPE SITE AND PLANTING PLANA1

WORK KEYNOTES

LS501

GENERAL SHEET NOTES

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

PLAN

NORTH

SCREEN WALL ENLARGEMENT PLANB1

WORK KEYNOTES

SCREEN WALL SECTIONC2

PLANTING NOTES

GRAPHIC SCALES

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

G E

N E

R A

L S

T R

U C

T U

R A

L N

O T

E S

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-001

14157105

1838720

GENERAL NOTES

1. USE THE STRUCTURAL DRAWINGS IN CONJUNCTION WITH THE DRAWINGS OF

ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. VERIFY THE

REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS,

INSERTS, ANCHORS, HOLES AND OTHER ITEMS TO BE PLACED OR SET IN THE

STRUCTURAL WORK.

2. ALL DIMNENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED.

3. COMPLY WITH SAFETY PRECAUTIONS AND REGULATIONS DURING THE WORK.

THE STRUCTURAL ENGINEER WILL NOT ADVISE ON NOR ISSUE DIRECTION AS

TO SAFETY PRECAUTIONS AND PROGRAMS.

4. THE STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISHED STRUCTURE.

PROVIDE TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD

THE STRUCTURE IN PROPER ALIGNMENT UNTIL STRUCTURAL WORK AND

CONNECTIONS HAVE BEEN COMPLETED. INVESTIGATE, DESIGN, VERIFY

SAFETY, VERIFY ADEQUACY AND INSPECT ERECTION BRACING, SHORING,

TEMPORARY SUPPORTS, ETC.

5. THE CONTRACTOR IS RESPONSIBLE FOR THE TEMPORARY SHORING AND

BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER

ALIGNMENT UNTIL PERMANENT SUPPORT, LATERAL BRACING, AND ROOF

DIAGRAM ARE IN PLACE.

6. STRUCTURAL SYSTEMS WHICH CONSIST OF FIELD ERECTED COMPONENTS

MUST BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY,

HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH THE SUPPLIER'S

INSTRUCTIONS AND REQUIREMENTS.

7. LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF

CONSTRUCTION MUST NOT EXCEED THE SAFE LOAD-CARRYING CAPACITY OF

THE STRUCTURAL MEMBERS. THE LIVE LOADINGS USED IN THE DESIGN OF

THIS STRUCTURE ARE INDICATED IN THE "DESIGN LOADS". DO NOT APPLY

CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY

CONNECTED AND UNTIL TEMPORARY BRACING IS IN PLACE.

8. SHOULD DISCREPANCIES ARISE BETWEEN THE DRAWINGS AND THE

SPECIFICATIONS, NOTIFY THE CONTRACTING OFFICER AND OBTAIN A WRITTEN

DETERMINATION BEFORE PROCEEDING WITH CONSTRUCTION. SHOULD

DISCREPANCIES ARISE BETWEEN THE DRAWINGS, NOTES, SPECS, AND/OR

DETAILS, THE MOST STRINGENT REQUIREMENTS APPLY. NOTIFY THE

CONTRACTING OFFICER OF SUCH DISCREPANCIES PRIOR TO PROCEEDING

WITH CONSTRUCTION.

9. DETAILS LABELED AS “TYPICAL” OR TYP” APPLY TO ALL SITUATIONS THAT ARE

THE SAME OR SIMILAR TO THESE SPECIFICALLY DETAILED. SUCH DETAILS

APPLY WHEATHER OR NOT THEY ARE KEYED IN AT EACH LOCATION ON THE

DRAWINGS. DIRECT QUESTION REGARDING APPLICABILITY OF TYPICAL

DETAILS TO THE CONTRACTING OFFICER.

10. GROUND FLOOR ELEVATION FOR THE MAIN FACILITY ARE REFERENCED FROM

0.00mm = 4500mm PER CIVIL DRAWINGS UNO.

11. REPRODUCTION OF CONTRACT DRAWINGS MUST NOT BE USED AS SHOP

DRAWINGS UNDER ANY CIRCUMSTANCE.

12. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUPPORT FOR ALL

EQUIPMENT AND MISCELLANEOUS HANGING ITEMS. COORDINATE. SIZE AND

LOCATION WITH DELEGATED DESIGN AS REQUIRED PER SPECIFICATIONS.

DESIGN LOADS

1. RISK CATEGORY III

2. LIVE LOADS

a. ROOF 1.0 kPa (20 PSF)

b. GROUND FLOOR 4.8 kPa (100 PSF)

c. MECHANICAL ROOMS 7.2 kPa (150 PSF)

d. ACCESS FLOOR 12 kPa (300 PSF)

3. SNOW DATA

a. GROUND SNOW LOAD, PG 4.8 KPa (100 PSF)

b. EXPOSURE FACTOR, CE 0.9

c. ROOF THERMAL FACTOR, CT 1.0

d. IMPORTANCE FACTOR, IS 1.1

4. WIND DATA

a. BASIC WIND SPEED, V 235 KM/H (146 MPH)

b. NOMINAL WIND SPEED 182 KM/H (113 MPH)

c. EXPOSURE D

d. INTERNAL PRESSURE COEFF. GCPI ±0.18

(ENCL BUILDING)

e. REFER TO SHEET S-003 FOR DESIGN ULTIMATE COMPONENTS AND

CLADDING WIND PRESSURE FOR ROOFS AND WALLS

5. SEISMIC DATA

a. SS 0.14G

b. S1 0.05G

c. SDS 0.15

d. SD1 0.08

e. IE 1.25

f. SITE CLASS D

g. SEISMIC DESIGN CATEGORY B

h. LATERAL FORCE RESISTING SYSTEM: ORDINEARY

PRECAST REINFORCED

CONCRETE SHEAR

WALLS

i. R 3

j. CD 3

k. ANALYSIS PROCEDURE ELF

l. CS 0.062

DOD CODES AND CRITERIA

THE APPLICABLE DESIGN STANDARDS AND/OR CRITERIA ARE AS FOLLOWS:

• UFC 1-200-01 – UNIFIED FACILITIES CRITERIA DOD BUILDING CODE, WITH

CHANGE 2, LAST UPDATED JUNE 12, 2023

• UFC 3-301-01 - UNIFIED FACILITIES CRITERIA STRUCTURAL ENGINEERING WITH

CHANGE 1, LAST UPDATED OCTOBER 02, 2023

• IBC 2021 – INTERNATIONAL CODE COUNCIL, INTERNATIONAL BUILDING CODE

• ASCE 7-16 – AMERICAN SOCIETY OF CIVIL ENGINEERS, MINIMUM DESIGN LOADS

FOR BUILDINGS AND OTHER STRUCTURES, 2016

• AISC 360-16 – AMERICAN INSTITUTE OF STEEL CONSTRUCTION,

SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, 2016

• ACI 318-19 – AMERICAN CONCRETE INSTITUTE, BUILDING CODE REQUIREMENT

FOR STRUCTURAL CONCRETE, 2019

• SDI RD-2017 – STEEL DECK INSTITUTE, STANDARD FOR STEEL DECKS, 2010

CANADIAN CODES AND CRITERIA

THE APPLICABLE DESIGN STANDARDS AND/OR CRITERIA ARE AS FOLLOWS:

• NBC-2020 - NATIONAL BUILDING CODE OF CANADA, 2020

• CSA A23.1/A23.2: 19 - CONCRETE MATERIALS AND METHODS OF CONCRETE

CONSTRUCTION

• CSA A23.3:19 - DESIGN OF CONCRETE STRUCTURES

• CSA A23.4:19 - PRECAST CONCRETE – MATERIALS AND CONSTRUCTION

• CSA G30.18:09 - CARBON STEEL BARS FOR CONCRETE REINFORCEMENT

• CSA S16:19 - DESIGN OF STEEL STRUCTURES

• CSA S136:16 - COLD FORMED STEEL

• CSA S304:14 - DESIGN OF MASONRY STRUCTURES

• CSSBI CANADIAN SHEET STEEL BUILDING INSTITUTE

CANADIAN DESIGN LOADS

1. BUILDING IMPORTANCE HIGH

2. WIND DESIGN DATA

A. q 1/50 0.75 kPa B. V 123 km/hr C. Iw 1.15 D. Open Exposure

3. SNOW DESIGN DATA

A. Ground snow load 2.4 kPa B. Rain 0.7 kPa C. Is 1.15

4. SEISMIC DESIGN DATA

A. SITE CLASIIFICATION D

B. Sa(0.2) 0.261 C. Sa(0.5) 0.296 D. Sa(1.0) 0.193 E. Sa(2.0) 0.0989 F. Sa(5.0) 0.0282 G. Sa(10.0) 0.00908 H. PGA 0.136g I. PGV 0.205g

J. IE 1.3

K. Sesmic Catagory SC3

FOUNDATIONS

1. FOUNDATIONS FOR THIS STRUCTURE HAVE BEEN DESIGNED IN ACCORDANCE

WITH THE DATA PROVIDED IN THE GEOTECHNICAL EXPLORATION REPORT,

PROVIDED BY AECOM-BAKER JF, DATED MARCH 29, 2024 AND THE

RECOMMENDATION OF THE GEOTECHNICAL ENGINEER OF RECORD FOR

NAVFAC ATLANTIC.

2. FOUNDATIONS HAVE BEEN DESIGNED FOR A BEARING PRESSURE OF 143 kPa

BOTTOM OF FOOTING MUST REST ON APPROVED SUBGRADE OR STRUCTURAL

FILL, REFER TO GEOTECHNICAL UNDERCUT PLAN ON B-201.

3. ACTIVE LATERAL EARTH PRESSURE ON WALLS = 6.3 kPa/M.

4. PRIOR TO PLACING FOUNDATION CONCRETE, ALL FOUNDATION EXCAVATIONS

MUST BE INSPECTED BY THE CONTRACTOR’S SPECIAL INSPECTOR.

5. PLACE FOUNDATION CONCRETE THE SAME DAY AS EXCAVATIONS ARE MADE

OR AS SOON AS PRACTICAL THEREAFTER.

6. BACKFILL UNDER ANY PORTION OF THE STRUCTURE MUST BE COMPACTED IN

200mm LIFTS.

7. FILL AND BACKFILL MUST BE COMPACTED TO A MINIMUM OF 95% ASTM D-698

DENSITY.

8. NO UNBALANCED BACKFILLING MUST BE DONE AGAINST WALLS UNLESS THEY

ARE SECURELY BRACED AGAINST OVERTURNING, EITHER BY TEMPORARY

CONSTRUCTION BRACING OR BY PERMANENT CONSTRUCTION.

SLAB ON GRADE

1. COMPACT SOIL TO PROVIDE A SATISFACTORY SUBGRADE FOR THE CONCRETE

SLAB-ON-GRADE. BACKFILL MATERIAL MUST BE GRAVELY SOIL, WELL-GRADED

SANDS, AND SAND GRAVEL MIXTURES RELATIVELY FREE OF PLASTIC FINED.

2. PROVIDE MINIMUM 200mm THICK POROUS FILL DIRECTLY UNDER VAPOR

RETARDER TO PREVENT WATER CAPILLARY ACTION. CAPILLARY WATER

RETARDER MUST BE NO 57 STONE MEETING THE REQUIERMENTS OF ASTM C33.

POROUS FILL MUST BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER ASTM

D 698.

3. ISOLATION JOINTS MUST BE USED AT JUNCTIONS WITH WALLS AND COLUMNS,

USE 12mm THICK PREMOLDED JOINTS FULL DEPTH OF SLAB.

4. VAPOR RETARDER, OVERLAPPED 150mm AT JOINTS, AND WITH A PERMEANCE

OF LESS THAN 0.3 PERMS IN ACCORDANCE WITH ASTM E-96. PROVIDE VAPOR

RETARDER WITH A MINIMUM THICKNESS OF 15 MILLS UNDER INTERIOR SLAB.

5. PROVIDE CONTROL JOINTS ON SLAB SURFACE, SEE PLAN FOR JOINT SPACING

AND LOCATIONS. JOINTS MUST BE SAWED WITHIN 24 HOURS AFTER CONCRETE

PLACEMENT.

6. ANY STRUCTURAL MEMBER PENETRATING SLAB IS TO BE SURROUNDED WITH

12mm PRE-MOLDED JOINT FILLER COMPLYING WITH ASTM D-1752, TYPE 1.

7. SEE THE ARCHITECTURAL AND PLUMBING DRAWINGS FOR EXACT LOCATIONS

OF DRAINS. SLOPE SLAB TO DRAINS WHERE SHOWN.

8. SLAB FINISH TYPE: INSIDE BUILDING – STEEL TROWELED, OUTSIDE SLAB –

BROOMED, UNLESS NOTED OTHERWISE.

CONCRETE

1. CONCRETE MUST BE NORMAL WEIGHT UNO AND CONFORM TO THE

FOLLOWING COMPRESSIVE STRENGTH REQUIREMENTS:

A. FOUNDATIONS C1 F’C = 35 MPa B. SLAB-ON-GRADE (OUTSIDE BUILDING) C2 F’C = 32 MPa C. SLAB-ON-GRADE (INTERIOR) N-CF F'C = 35 MPa1 D. ALL OTHER CONCRETE C2 F'C = 32 MPa

2. PROVIDE REINFORCING THAT MEETS THE FOLLOWING CRITERIA:

A. CSA G30.18, DEFORMED FY = 400 MPa B. WELDED WIRE REINFORCEMENT CSA G30.15 FY = 400 MPa

3. DETAIL AND PLACE REINFORCEMENT IN ACCORDANCE WITH REINFORCING

STEEL INSTITUTE OF CANADA (RSIC) MANUAL. 1

4. UNLESS OTHERWISE NOTED, THE FOLLOWING MINIMUM CONCRETE COVER

MUST BE PROVIDED FOR REINFORCEMENT:

A. CONCRETE DEPOSITED AGAINST THE GROUND 75mm B. CONCRETE EXPOSED TO EARTH OR WEATHER 60mm C. 15M AND SMALLER 40mm D. 20M AND LARGER 50 mm

E. NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND

F. SLABS AND WALLS 40mm

5. PROVIDE DOWELS TO MATCH REINFORCEMENT SIZE AND SPACING INDICATED

FOR ALL STRUCTURAL ELEMENTS, UNO.

6. PROVIDE WATERSTOPS IN ALL CONSTRUCTION JOINTS AT OR BELOW GRADE.

7. CONCRETE WALLS MUST BE TEMPORARILY BRACED AGAINST EARTH

PRESSURE AND WIND FORCED UNTIL ROOF STRUCTURE AND DIAPHRAGM IS IN

PLACE.

8. SEE ARCHITECTURAL, MECHANICAL, AND OTHER DISCIPLINES FOR LOCATIONS

OF OPENINGS AND SLEEVES IN CONCRETE WALLS AND SLAB. SPREAD

REINFORCEMENT AT OPENINGS AND SLEEVES, UNO DO NOT CUT

REINFORCEMENT. SEE TYPICAL REINFORCEMENT DETAILS FOR OPENINGS IN

SLABS AND WALLS FOR ADDITIONAL REQUIREMENTS.

9. CHAMFER EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES 20mm, UNO.

STRUCTURAL STEEL

1. STRUCTURAL STEEL MUST CONFORM TO CSA S16.

2. MATERIALS: MUST CONFORM TO CSA G40.21 UNLESS OTHERWISE NOTED, WITH

THE FOLLOWING GRADES,

A. WIDE FLANGE SHAPES – GRADE 50W, FY = 345 MPa B. ANGLES, CHANNELS - GRADE 44W, FY = 300 MPa C. HSS RECTANGULAR – GRADE 50W, FY = 345 MPa D. HSS ROUND – GRADE 50W, FY = 345 MPa E. PLATES – GRADE 44W, FY = 300 MPa

F. WELDING ELECTRODES – AWS D1.1, E70XX, FILLET WELD SIZE TYPICAL

6mm, UNO.

3. UNLESS OTHERWISE NOTED, STEEL PERMANENTLY EXPOSED TO THE

WEATHER MUST BE GALVANIZED OR PAINTED.

4. THE CENTER LINES OF ALL COLUMNS AND BEAMS SHALL BE LOCATED ON

COLUMN LINES UNO.

5. USE 20mm HIGH STRENGTH BOLT PER ASTM F3125 GRADE A325. PROVIDE

STANDARD OR SHORT SLOTTED HOLES UNO.

6. ERECT ALL BEAMS WITH NATURAL CAMBER UP.

7. PROVIDE TEMPORARY ERECTION BRACING AND SUPPORTS TO HOLD

STRUCTURAL STEEL FRAMING SECURELY IN POSITION. SUCH TEMPORARY

BRACING AND SUPPORT MUST NOT BE REMOVED UNTIL PERMANENT BRACING

HAS BEEN INSTALLED AND ROOF DECK IS INSTALLED.

8. FIELD CUTTING OF STRUCTURAL STEEL OR ANY FIELD MODIFICATIONS OF

STRUCTURAL STEEL MUST NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL

BY CONTRACTING OFFICER FOR EACH SPECIFIC CASE

9. ANCHORS SHALL CONFORM TO ASTM F1554, GRADE 55, UNO.

10. NON-SHRINK GROUT TYPICAL FOR BASE PLATES TO COMPLY WITH ASTM C1107

WITH MINIMUM COMPRESSIVE STRENGTH 48 MPa AT 28 DAYS.

11. STEEL BEAM CONNECTIONS SHOWN ARE FULLY DESIGNED. CONTRACTOR HAS

THE OPTION TO SUBMIT ALTERNATE CONNECTION DETAILS AT NO ADDITIONAL

COST FOR APPROVAL. CONNECTION DESIGNS MUST BE DESIGNED PER CSA

S16 USING THE END REACTIONS PROVIDED ON S-003. SUBMIT DESIGNS IN SHOP

DRAWINGS WITH CALCULATIONS THAT ARE SIGNED AND SEALED BY A

PROFESSIONAL ENGINEER LICENSED IN CANADA.

METAL DECK

1. ROOF DECK MUST BE G90 GALVANIZED STEEL CONFORMING TO CSA S136 WITH

A MINIMUM YIELD STRENGTH OF 345 MPa. STEEL ROOF DECK MUST BE 38mm

DEEP TYPE B DECK WITH THE FOLLOWING MINIMUM SECTION PROPERTIES:

A. T= 1.2mm (18 GAGE) B. IP= 370 x 103 mm4/m C. SP=16.45 x 103 mm3/m D. SN= 17.10 x 103 mm3/m

2. ROOF DECK MUST BE FASTENED TO THE SUPPORTING STRUCTURE WITH

16mmØ PUDDLE WELDS CREWS AT 914/5 PATTERN. SIDE LAP CONNECTIONS

MUST BE MADE WITH #10 SELF TAPPING SCREWS AT QUARTER POINTS

BETWEEN SUPPORTS NO FURTHER THAN 300mm ON CENTER. FASTEN

DISCONTINUOUS SIDE OF ROOF DECK TO BENT PLATE STRUCTURE WITH

16mmØ PUDDLE WELDS AT 304mm ON CENTER.

3. STEEL DECKS ARE PART OF THE LATERAL LOAD SYSTEM.

4. WHERE 4 OR MORE SUPPORTS ARE PROVIDED, STEEL DECK SHALL SPAN

CONTINUOUSLY OVER A MINIMUM OF 3 SUPPORTS (2-SPAN CONDITION),

UNLESS OTHERWISE NOTED.

5. PROVIDE 1.5mm THICK RIDGE PLATES, VALLEY PLATES AND MISCELLANEOUS

METAL DECK ACCESSORIES MUST BE PROVIDED AND INSTALLED BY THE

CONTRACTOR IN ACCORDANCE WITH THE DECK MANUFACTURER’S

RECOMMENDATIONS.

6. PERMANENT SUSPENDED LOADS MUST NOT BE SUPPORTED BY STEEL ROOF

DECK.

7. DECKS, FASTENERS AND ACCESSORIES MUST BE HOT DIP GALVANIZED, G90.

8. DECK SUPPLIER MUST DESIGN AND PROVIDE REINFORCING FOR ALL ROOF

DECK OPENINGS BETWEEN 150 AND 300 WIDE, REFER TO ARCHITECTURAL AND

MECHANICAL DRAWINGS FOR LOCATIONS. CLEAR SPACING BETWEEN

ADJACENT OPENINGS TO BE MIN. 3 TIMES THE WIDTH OF THE LARGER

OPENING. FOR LARGER OPENINGS REFER TO DETAIL ON S-503.

9. CONTRACTOR HAS THE OPTION TO USE POWDER ACTUATED FASTENERS IN

PLACE OF WELD AT NO ADDITIONAL COST TO THE GOVERNMENT.

CONTRACTOR MUST SUBMIT CALCULATIONS THAT ARE SIGNED AND SEALED BY

AN ENGINEER LICENSED IN CANADA THAT DEMONSTRATE THE POWDER

ACTUATED FASTENERS PROVIDE THE SAME OR GREATER DECK SHEAR

CAPACITY AS THE WELDS.

SPECIAL INSPECTIONS

1. SPECIAL INSPECTION AND TESTING MUST CONFORM TO SECTION 1704 OF THE

INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY UFC 1-200-1 AND UFC

3-301-01.

2. ONE OR MORE QUALIFIED SPECIAL INSPECTION & TESTING AGENCIES MUST BE

EMPLOYED BY THE CONTRACTOR TO PERFORM THE NECESSARY INSPECTION

OF IBC SECTION 1705, AS APPLICABLE. QUALIFICATIONS FOR SPECIAL

INSPECTION AND TESTING AGENCIES AND INSPECTORS MUST BE SUBMITTED

TO THE CONTRACTING OFFICER FOR REVIEW AND APPROVAL.

3. SPECIAL INSPECTOR QUALIFICATIONS MUST MEET THE REQUIREMENTS OF

SPECIFICATION SECTION 01 45 35.

4. FOR STATEMENT OF SPECIAL INSPECTION SEE PROJECT SPECIFICATIONS.

PRECAST CONCRETE WALLS

1. DESIGN PRECAST CONCRETE MEMBERS AND CONNECTIONS IN ACCORDANCE

WITH CSA-A23.1 AND CSA-A23.4.

2. PRECAST MANUFACTURERS MUST HAVE PRECAST CERTIFICATION WITH CPCI

OR CSA.

3. PRIOR TO FABRICATION THE CONTRACTOR MUST SUBMIT THE FOLLOWING TO

THE CONTRACTING OFFICER. DOCUMENTS MUST BE SIGNED AND SEALED BY A

PROFESSIONAL ENGINEER LICENSED IN CANADA.

A. DESIGN CALCULATIONS INCLUDING DESIGN CRITERIA, REACTION

FORCES, LOAD CAPACITIES, AND CONNECTIONS.

B. SHOP DRAWINGS SHOWING ERECTION PLANS, REINFORCEMENT LAYOUT,

CONNECTIONS, DETAILS, DIMENSIONS, AND OPENING SIZES AND

LOCATIONS.

4. PRECAST WALLS ARE PART OF THE LATERAL FORCE RESISTING SYSTEM AND

MUST MEET THE DETAILING REQUIREMENTS OF LOAD BEARING ORDINARY

PRECAST CONCRETE SHEAR WALLS.

5. DESIGN PRECAST LOAD BEARING WALLS AND CONNECTION FOR LOADING

GIVEN IN THE CONTRACT DOCUMENTS INCLUDING DEAD LOAD OF THE ROOF

AND WALL, ROOF LIVE LOAD, SNOW LOAD, ROOF AND WALL WIND LOAD, OUT

OF PLANE SEISMIC LOAD, AND IN PLANE SHEAR WALL WIND AND SEISMIC

LOADS. DESIGN WALLS USING THE MOST UNFAVORABLE LOAD COMBINATION.

6. CONNECTIONS AND WALL REINFORCEMENT SHOWN PROVIDE MINIMUM

REQUIREMENTS, AND ANY DEVIATION FROM PROVIDED DETAILS MUST BE

APPROVED BY THE CONTRACTING OFFICER. SUGGESTED DETAILS ON THE

DRAWINGS DO NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF

DESIGNING THE PRECAST WALLS AND CONNECTIONS.

7. EACH PANEL MUST HAVE A MINIMUM OF TWO POINTS TO TRANSFER GRAVITY

LOADS, FOUR POINTS TO TRANSFER LATERAL LOADS AND TWO POINTS TO

TRANSFER LONGITUDINAL LOADS. EACH CONNECTION MAY SERVE TO RESIST

MORE THAN ONE TYPE OF LOADING.

8. COORDINATE WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL,

PLUMBING, FIRE PROTECTION, LANDSCAPING AND CIVIL DRAWINGS FOR

LOCATIONS OF EMBEDS, OPENINGS AND POCKETS IN MEMBERS. PROVIDE

SLEEVES FOR MECHANICAL PIPES AND ELECTRICAL CONDUITS THROUGH THE

PRECAST MEMBERS. CONTRACTOR MUST VERIFY SIZE AND LOCATIONS OF

OPENINGS IN PRECAST MEMBERS WITH THE TRADE REQUIRING THE SLEEVE.

9. GALVANIZE ALL STEEL PLATES, SHAPES, AND ANCHORS USED FOR PRECAST

WALLS UNLESS NOTED OTHERWISE. PAINT ALL WELDS WITH ZINE RICH REPAIR

PAINT AFTER WELDING. CONNECTIONS BELOW GRADE THAT ARE EXPOSED

MUST BE PAINTED WITH COAL TAR EPOXY.

10. PRECAST CONCRETE SUPPLIER MUST FURNISH ALL LOOSE CLIP ANGLES,

INSERTS, AND WELD PLATES NECESSARY FOR PROPER INSTALLATION.

11. PRECAST CONCRETE SUPPLIER MUST LOCATE PICKUP POINTS, SELECT PICKUP

HARDWARE, SELECT TEMPORARY BRACING AND BE RESPONSIBLE FOR

DESIGNING AND SUPPLYING ANY ADDITIONAL REINFORCING, SHORING, ETC. AS

REQUIRED FOR ERECTION PURPOSES.

12. PRECAST CONCRETE STRENGTH F'C =35 MPa, MINIMUM.

COLD FORMED METAL FRAMING

1. REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR COLD-FORMED

METAL FRAMING MEMBERS LOCATIONS, SIZES AND PROPERTIES.

2. LIGHT GAGE MEMBERS AND DETAILS SHOWN ON THE ARCHITECTURAL OR

STRUCTURAL DRAWINGS ARE FOR BID PURPOSES ONLY. STRUCTURAL

STUD AND/OR SOFFIT FRAMING MEMBERS AND CONNECTIONS ARE TO BE

ENGINEERED BY THE MANUFACTURE. DESIGN CALCULATIONS AND SHOP

DRAWINGS MUST BE SUBMITTED TO THE CONTRACTING OFFICER FOR

REVIEW. DESIGN IN ACCORDANCE WITH CSA S136 USING LOADS PROVIDED.

3. ALL COLD-FORMED STEEL TO BE FORMED FROM CORROSION RESISTANT

STEEL CONFORMING TO CSA-S136-16 (R2021) WITH A MINIMUM YIELD

STRESS OF 345 MPA AND MINIMUM THICKNESS OF 1.5MM.

4. FRAMING COMPONENTS ARE TO BE CUT SQUARELY FOR ATTACHMENT TO

PERPENDICULAR MEMBERS OR AS REQUIRED FOR AN ANGULAR FIT

AGAINST ABUTTING MEMBERS.

5. FIELD CUTTING OF STUDS MUST BE DONE BY SAWING OR SHEARING,

TORCH CUTTING OF COLD-FORMED MEMBERS IS UNACCEPTABLE.

6. PROVIDE VERTICAL SLIDE TRACKS OR SLIDE CLIPS WHERE INDICATED ON

THE DRAWINGS OR OTHERWISE REQUIRED TO ALLOW FOR VERTICAL

STRUCTURAL MOVEMENT. MAXIMUM EXPECTED STRUCTURAL LIVE LOAD

DEFLECTION IS L/240 FOR ROOFS.

7. DESIGN ROOF OVERHANGS FOR 1.0 KPA LIVE LOAD, 3.4 KPA SNOW LOAD,

AND C&C WIND LOADS INDICATED ON S-003.

A

M E

N D

M E

N T

3/

/2

R E

V

IS

E D

N O

T

S

W305x35

TOS XXX

FRAMING SIZE

X

TOP OF STEEL

COLUMN GRID MARK

KEY NOTE

T/WALL XXX

TOP OF WALL

T/SLAB XXX

TOP OF SLAB

XXXX

TOP OF SLAB SPOT ELEVATION

X:Y

CHANGE IN ROOF/SLAB ELEVATION

SLAB-ON-GRADE JOINT

NORMAL ROOF SLOPE

DECK/SLAB SPAN DIRECTION

WORK POINT

FD FLOOR DRAIN

30 MPa 32MPa

Ld Ls

BAR

SIZE

OTHER

78010M

15M

20M

25M

30M

35M

TOP BAR

45M

55M

Ldh

EMBEDMENT AND LAP SPLICE LENGTHS

CASE 2CASE 1 CASE 2CASE 1

OTHERTOP BAR

CASE 2CASE 1 CASE 2CASE 1

Ld Ls

OTHERTOP BAR Ldh

CASE 2CASE 1 CASE 2CASE 1

OTHERTOP BAR

CASE 2CASE 1 CASE 2CASE 1

35 MPa

NOTES:

1. VALUES ARE BASED ON FY = 400 MPa REINFORCING BARS AND NORMAL WEIGHT CONCRETE.

2. CASE 1 IS APPLICABLE WHEN ONE OF THE FOLLOWING CONDITIONS ARE SATISFIED:

A. CLEAR COVER ≥ 1.0 db, CENTER TO CENTER SPACING ≥ 2db, AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN THE CODE MINIMUM.

B. CLEAR COVER ≥ 1.0 db AND CENTER TO CENTER SPACING ≥ 3.0 Db

3. CASE 2 IS APPLICABLE WHEN CASE 1 CONDTITIONS ARE NOT MET.

4. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 300mm OF FRESH CONRETE PLACED BELOW.

5. FOR 35M B2ARS AND SMALLER Ldh MAY BE MULTIPLIED BY 0.63 IF CENTER TO CENTER SPACING IS ≥ 6db

6. FOR 35M BARS AND SMALLER Ldh MAY BE MULTIPLIED BY 0.8 IF SIDE COVER NORMAL TO PLANE OF HOOK ≥ 6db.

7. THE TOTAL REDUCED DEVELOPMENT Ldh FOR NOTES 5 AND 6 MUST NOT BE LESS THAN THE GREATER OF 8db AND 150mm.

600400 1010680 780520 480220 370720 630560 480940 210720

1100740 850570 1430960 1100740 680360 5601020 890790 6801330 3601020

1340900 1030690 17401160 1340900 830480 6401240 1080960 8301610 4801240

21701450 16701110 28101880 21701450 1340700 10302010 17401540 13402610 7002010

25701710 19801320 33402230 25701710 1590910 12202380 20601830 15903090 9102380

30602040 23501570 39702650 30602040 18901180 14502830 14502180 18903680 11802830

37502500 28901930 -- -- 23201600 17803470 -2670 -- 1600-

48403230 37202480 -- -- 29902340 23004480 -2300 -- 2340-

L1

L2

Ldh Ldh

D1 D1

D1

180° HOOK 90° HOOK BEND

135° HOOK

D2

L3

STANDARD HOOKS AND BEND LENGTHS

STANDARD 90 AND 180

DEGREE HOOKS

STIRRUPS, TIES,

AND HOOPS

BAR

SIZE L1 L2 D2 L1 L2 L3

1407010M 50 70 80 80

15M

20M

25M

30M

35M

D1

45M

55M

Ls

Ld

STRAIGHT BAR

20080 65 70 100 100100

24090 120 80 240 120120

300120 150 100 300 150150

360140 180 120 360 220240

430160 220 150 430 270285

530200440

680250565

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

L E

G E

N D

S A

N D

A B

B R

E V

IA

T

IO

N

S

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-002

14157106

1838720

ACI AMERICAN CONCRETE INSTITUTE

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

AR ANCHOR ROD

ARCH ARCHITECTURE

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

ASTM AMERICAN STANDARDS OF TESTING AND MATERIALS

AWS AMERICAN WELDING SOCIETY

CANT CANTILEVER

CL CETNER LINE

CONT CONTINUOUS

CSA CANADIAN STANDARDS ASSOCIATION

CSSBI CANADIAN SHEET STEEL BUIDLING INSTITUTE

CJ CONSTRUCTION JOINT

DIA DIAMETER

EA EACH

EF EACH FACE

ELF EQUIVALENT LATERAL FORCE

ENCL ENCLOSED

EW EACH WAY

F'C CONCRETE COMPRESSIVE STRENGTH

FY STEEL YIELD STRENGTH

GB GRADE BEAM

IBC INTERNATIONAL BUILDING CODE

IJ ISOLATION JOINT

JT JOINT

kN KILO NEWTON kPa KILO PASCAL

LD DEVELOPMENT LENGTH

LW LONG WAY

MIN MINIMUM

MFR MANUFACTURER

NBC NATIONAL BUILDING CODE

Ø DIAMETER

OC ON CENTER

OPNG OPENING

PL PLATE

REINF REINFORCEMENT

REQD REQUIRED

SDI STEEL DECK INSTITUTE

SF STEPPED FOOTING

SIM SIMILAR

SM SQUARE METER

SOG SLAB-ON-GRADE

SPA SPACED

SW SHORT WAY

TOF TOP OF FOOTING

T/SLAB TOP OF SLAB

TOW TOP OF WALL

TYP TYPICAL

UFC UNIFIED FACILITIES CRITERIA

UNO UNLESS NOTED OTHERWISE

VERT VERTICAL

W/ WITH

WHS WELD HEADED STUD

ABBREVIATIONS ABBREVIATIONS TYPICAL REINFORCEMENT BEND AND SPLICE DETAILS

A

M E

N D

M E

N T

3/

/2

U P

D A

T E

D L

A P

S P

LI

C

E T

A B

LE

A

D

B

C

4 5 6

9430 9720 9970 9970 6250

C1

S-301

C2

S-301

A1

S-301

C3

S-301

WF900

W F

WF1000

W F

W F

W F

W F

W F

WF900

WF1000

CF 2500 CF 2500

C1 C1

W F

TYP

T/SLAB= -1200

T/SLAB= -1200T/SLAB= 0

TOF= -1800

TOF= -1000

TOF= -1800TOF= -1000

C4

S-301

CF 2500

C1C1

CF 2500

TYP

SF

SF

A4

S-501

2.00°

170 170

TYP

A2

S-301

WF900B

W F

0B

W F

0B

B4

S-301

A4

S-301

TYP

WF2100

48710

2.

2.

2.

2.

2.

200 3891560

TOF= -1000TOF= -1800

TOF= -1000TOF= -1800

SF

SF

WF1000

WF1000

WF900

TYP

TYP

SF

SF

TOF= -1800

TOF= -1000

TOF= -1800

TOF= -1000

WF2100

S-502 A3

TYP

WF900

B3

S-501

TYP

B1

S-501

TYP

S-502 B1

TYP

A3

S-401

TS900

T S

T S

TOF= -1800 TOF= -1800 TOF= -1800 TOF= -1800

TYP

-25

TYP

TYP

TYP

2.00°

W F

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

F O

U N

D A

T

IO

N P

L A

N

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-101

14157108

1838720

1:100 0 1000 5000 10000mm

FOUNDATION SHEET NOTES

GRAPHIC SCALE(S)

FOUNDATION KEYNOTES

1 : 100

FOUNDATION PLAN

1 150mm CONCRETE SLAB-ON-GRADE REINFORCED WITH ONE LAYER OF M10 @ 300mm OC EACH WAY REFER TO S-502 FOR DETAILS.

2 250mm CONCRETE SLAB-ON-GRADE REINFORCED WITH TWO LAYERS OF M10 @ 300 mm OC REFER TO S-502 FOR DETAILS. PROVIDE EQIPOTENTIAL GROUND PLANE IN

SLAB. COORDINATE WITH ELECTRICAL, SEE EG101.

3 PROVIDE CONSTRUCTION JOINT OR CONTROL JOINT IN AREAS INDICATED.

CONSTRUCTION JOINT LOCATIONS ARE AT CONTRACTOR'S DISCRETION.

4 450mm THICK PRECAST CONCRETE INSULATED WALL. REFER TO S-504 FOR

DETAILS.

5 250mm THICK PRECAST CONCRETE WALL. REFER TO S-504 FOR DETAILS.

6 SOLID PRECAST CONCRETE WALL/JAMB.

7 200mm THICK PRECAST CONCRETE FENCE WALL. REFER TO S-301 FOR DETAILS

AND LA DWGS FOR LOCATION.

8 150mm EQUIPTMENT PAD, SEE DETAIL ON S-502, COORDINATE SIZE WITH MANUF.

9 TANK SADDLE SUPPORT PIER, COORDINATE WITH TANK SADDLE LOCATION.

10 APPROXIMATE UTILITY LOCATION. COORDINAT EXACT LOCATION WITH CIVIL,

PLUMBING, AND ELECTRICAL DRAWINGS. PROVIDE PIPE SLEEVES IN PRECAST

WALLS AS REQUIRED.

11 APPROXIMATE LOCATION OF SET OF (3) CONDUITS, COORDINATE EXACT LOCATION

WITH ELECTRICAL.

12 PROVIDE SUFFICIENT OPENING IN WALL FOR BASEPLATE INSTALLATION.

13 DROPPED SLAB SEE ARCH. COORDINATE LOCATION WITH SHOWER.

14 LADDER SUPPORT/DOOR JAMB, SEE DETAIL ON S-504.

15 EQUIPOTENTIAL GROUND PLANE COORDINATE WITH ELECTRICAL, SEE EG101.

A. REFER TO S-001 FOR GENERAL NOTES AND S-501 AND S-502 FOR

MISCELLANEOUS FOUNDATION DETAILS.

B. ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE RELATIVE TO A

REFERENCE ELEVATION OF 0.00 T/SLAB (TOP OF GROUND FLOOR SLAB).

C. TOP OF FOOTING ELEVATION = -1000 UNO AS TOF. APPROXIMATE STEPPED

FOOTING LOCATIONS ARE INDICATED AS "SF" ON PLAN. REFER TO TYPICAL

STEPPED FOOTING DETAIL ON S-501.

D. “CF _” REFERENCES A CONCRETE COLUMN FOOTING. REFER TO SCHEDULE ON

S-501.

E. “WF_” REFERENCES A CONCRETE WALL FOOTING. REFER TO SCHEDULE ON

S-501.

F. “C_” REFERENCES A STEEL COLUMN. REFER TO COLUMN SCHEDULE ON S-503.

G. SEE ARCH FOR DIMENSIONS NOT SHOWN.

PLAN

NORTH

A

M E

N D

M E

N T

3/

/2

R E

V

IS

E D

S

LA

B L

O C

A T

IO

N

A N

D K

E Y

N O

T

GROUND FLOOR

TOP OF FOOTING

-1000

D

PRECAST CONCRETE

WALL

SLAB-ON-GRADE

EXTERIOR

GRADE/PAVEMENT,

SEE CIVIL

FOOTING

PRECAST CONCRETE WALL

CONNECTION PROVIDED BY

PRECAST MANUFACTURER.

CONTRACTOR MUST

COORDINATE EMBEDS WITH

WITH MANUFACTURER PRIOR

TO PLACING FOOTING. STEEL

PLATES AND ANCHORS BELOW

GRADE MUST BE COATED WITH

HEAVY BLACK ASPHALTUM.

12mm PREMOLDED

JOINT FILLER AT

WALL, TYP

INSULATION, SEE ARCH

HYDROPHILIC

WATERSTOP, TYP

GROUND FLOOR

TOP OF FOOTING

-1000

D

EXTERIOR PAVEMENT,

SEE CIVIL SLAB-ON-GRADE

CIP OR PRECAST

CONCRETE WALL AT

DOOR OPENING

FOOTING

15M @ 300 EW

WALL BEYOND

GROUND FLOOR

TOP OF FOOTING

-1000

D

PRECAST CONCRETE BEAM

DESIGN FOR GRAVITY

LOADS AND OUT OF PLANE

WALL LOADS ON S-003

PRECAST

CONCRETE WALL

CIVIL PAVEMENT

SLAB-ON-GRADE

FOOTING

INSULATED METAL PANEL, SEE ARCH

CONTRACTOR MUST DESIGN FOR 20

PSF LIVE LOAD

SLAB-ON-GRADE

T/WALL 3250

WALL BEYOND

L127X127X9.5 EDGE ANGLE AROUND

PERIMETER W/ 20mmØ POST INSTALLED THREADED RODS 200mm EMBED @600mm O.C.

C

12mm PREMOLDED

JOINT FILLER

GROUND FLOOR

C

-1200

-1800

SLAB-ON-GRADE

SLAB-ON-GRADE

FOOTING

PRECAST CONCRETE WALL

T/SLAB =

TOF=

GROUND FLOOR

SLAB-ON-GRADE

SLAB-ON-GRADE

FOOTING

CIP OR PRECASTCONCRETE

WALL AT DOOR OPENING

DOWELS TO MATCH

SIZE AND SPACING OF

VERTICAL REINF.

15M @ 300 EA WAY,

CENTER

GROUND FLOOR

A

EXTERIOR GRADE

SEE CIVIL

150mmØ DRAIN PIPE

SEE CIVIL

#57 STONE

SLAB-ON-GRADE

PRECAST WALL

FOOTING

MIN

M

IN

POROUS FILL

CONTINUOUS

FILTER CLOTH

FILTER CLOTH

GROUND FLOOR

TANK SADDLE BY

MANUFACTURER

ANCHOR ROD BY TANK

MANUFACTURER

COORDINATE PRIOR TO

PLACING CONCRETE

15M @ 300mm

(4) 15M LONG

GROUND FLOOR

TOP OF FOOTING

-1000

EXTERIOR GRADE/PAVEMENT,

SEE CIVIL

MECHANICAL YARD, SEE CIVIL

PRECAST CONCRETE WALL

CONNECTION BY MANUFACTURER

MU = 6.0 kN*M/M

FOOTING

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

S E

C T

IO

N

S

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-301

14157111

1838720

1 : 20 (S-101) C1

SECTION

1 : 20 (S-101)

C2

SECTION

1 : 20 (S-101) A1

SECTION

1 : 20 (S-101) C3

SECTION

1 : 20 (S-101)

C4

SECTION

1 : 20 (S-101) A2

SECTION

1 : 20 (S-101) A4

SECTION

1 : 20 (S-101) B4

SECTION

A

M E

N D

M E

N T

3/

/2

R E

V

IS

E D

S E

C T

IO

N

STEEL

DECK

ROOF BEAM

SEE SHEAR TAB

CONNECTION DETAIL

STEEL DECK

PRECAST

CONCRETE WALL

EDGE ANGLE W/

EMBED PLATE,

SEE PLAN

T/WALL = SEE PLAN

ELEVATION VARIES, SEE PLAN

C

D

STEEL DECK

PRECAST CONCRETE

WALL

ROOF BEAM

SEE TYPICAL SHEAR TAB

CONNECTION DETAIL

ROOFING, SEE ARCH

PRECAST COPING, SEE ARCH FOR DIMENSIONS

SEE PLAN

TOS

SEE PLAN

TOW

D

EDGE ANGLE W/ EMBED

ROD, SEE PLAN

STEEL DECK

PRECAST CONCRETE WALL

SEE PLAN

TOS

A

HIGH ROOF

SEE PLAN

COLD-FORMED STEEL

ROOF OVERHANG - SEE

DETAIL A3/S-504

STEEL DECK

ROOF BEAM

PRECAST

CONCRETE WALL

SEE CONNECTION

DETAIL

CONT 9.5mm EMBED PLATE W/ 12mm Ø WHS

150 EMBED @ 600 OC

WELD DECK TO

PLATE PER

NOTES ON S-001

STEEL DECK

ROOF BEAMPRECAST CONCRETE WALL

COLD FORMED STEEL

ROOF OVERHANG -

SEE DETAIL A3/S-504

TYP

CONT 9.5mm EMBED PLATE W/ 12mm Ø WHS 150 EMBED

@ 600 OC

TYP

TYP

A

A

B

STEEL DECK

9.5mm CAP PLATE

GIRDER

ROOF BEAM

SEE CONNECTION

DETAIL ON S-503

PRECAST CONCRETE

WALL

HSS COLUMN

STEEL DECK

ROOF BEAM

GIRDER

SEE CONNECTION

DETAIL

CONT 9.5mm EMBED PLATE W/ 12mm Ø WHS

150 EMBED @ 600 OC

9.5mm PLATE W/(2) 25MM Ø

THRU BOLTS FINGER TIGHT

W/LONGSLOTTED HOLES IN

PLATE. SPOIL THREADS

AFTER INSTALL.

SEE PLAN

12mm EBED PLATE W/(4) Ø12mm WHS

Ø5 SDS @ 150OC

HSS 51X38X5 AT 915 OC (MAX)

IN FLUTE. COORDINATE WITH

DECK INSTALLER

C

SEE PLAN

PRECAST WALL

STEEL BEAM

STEEL BEAM

SEE PLAN

TOS

ROOF DECK

9.5mm FULL DEPTH STIFFENER

C310

ROOF BEAM

(2) 20mm BOLTS

PRECAST JAMB/COLUMN

SEE PLAN

PRECAST CONCRETE

HEADER BEAM

WALL JAMB

PRECAT WALL

BEARING PAD

BEARING PAD

CONCRETE CORBEL

BY PRECASTER

DESGIN FOR:

DL = 65kN LL = 16 kN SL = 65kN

CONNECTION

WALL

NOTE:

DESIGN HEADER BEAM, CORBEL, BEARING PAD, JAMBS, COLUMNS, AND CONNECTIONS FOR GRAVITY AND LOADS AND

OUT OF PLANE WALL LOADS ON S-003 AND BEARING LOADS IN THIS DETAIL.

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

S E

C T

IO

N

S

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-302

14157112

1838720

1 : 20 (S-102) A2

SECTION

1 : 20 (S-102) C1

SECTION

1 : 20 (S-102)

C2

SECTION

NOT TO SCALE (S-103)

B1

SECTION

1 : 20 (S-103)

B2

SECTION

1 : 20 (S-103) C3

SECTION

NOT TO SCALE

A1

SECTION

1 : 10

A-A

NOT TO SCALE

B4

SECTION

NOT TO SCALE

C4

SECTIONS

1 : 20 (S-102) A4

SECTION

A

M E

N D

M E

N T

3/

/2

R E

V

IS

E D

S E

C T

IO

D /3

D /3

D /3

D

NEW POURPREVIOUS POUR

WIDTH OF FOOTING

50 KEY FULL

(3) 15M x 1200 TOP

CENTERED ON JOINT

BOTTOM REINFORCEMENT

CONTINUOUS THRU JOINT

100100

TO

P

C

LE

A

R

TIE BAR EACH SIDE OF

CONSTRUCTION JOINT

NOTE: PROVIDE VERTICAL HYDROPHILIC WATERSTOP IN

JOINT BELOW WALL.

0m m M

A X

M

IN

200mm STEP

400mm MIN

CONTINUOUS WALL

FOOTING

REINFORCEMENT

CONTINUOUS WALL

FOOTING REINFORCEMENT

'Z' BARS SAME SIZE AND

NUMBER AS

CONTINUOUS FOOTING

REINFORCEMENT, BEND

AS SHOWN

DIAMETER

16 x BAR

DIAMETER16 x BAR

75 C

LEAR

'D

D E

P

TH

'D

LAP SPLICE

0" T

Y P

ONE TIE EACH END

OF FOOTING STEP

(TYPICAL)

50m m

C

LEAR

m m C

LE

A

R

UTILITY PERPENDICULAR TO AND BELOW FOOTING

0m m M

A X

M

IN

(TYPICAL)

300mm MIN

M

IN

10 MPa LEAN CONCRETE, WIDTH

EQUAL TO CONTINUOUS FOOTING

WIDTH, PLACED BEFORE FOOTING IS

PLACED

NON-CORROSIVE METAL PIPE

SLEEVE (INSIDE Ø = OUTSIDE PIPE Ø

+ 50mm MIN)

CONTINUOUS

WALL FOOTING

CONTINUOUS

REINFORCEMENT

MIN

UTILITY PARALLEL TO FOOTING

FOUNDATION WALL

AND FOOTING BACKFILL

PIPE/CONDUIT IN TRENCH

NO TRENCH EXCAVATION PARALLEL

TO FOOTING BELOW THIS LINE. STEP

FOOTING PER DETAIL TO ENSURE

LINE IS BELOW EXCAVATION

NO TRENCH EXCAVATION PARALLEL TO

FOOTING BELOW THIS LINE. STEP

FOOTING PER DETAIL TO ENSURE LINE IS

BELOW EXCAVATION

WHEN PIPE/CONDUIT TRENCH

FALLS BELOW THE 2:1 PLANE BUT IS

ABOVE THE 1:1 PLAN, FILL TRENCH

WITH 10 MPa LEAN CONCRETE

NOTES:

1. PERPENDICULAR PIPE SLEEVE THROUGH / BELOW FOOTING MUST EXTEND TO EDGE OF 1:1 BEARING ZONE ON EACH SIDE OF FOOTING UNLESS OTHERWISE NOTED.

2. IF UTILITY LINE IS IN PLACE PRIOR TO PLACING CONCRETE, WRAP UTILITY WITH 25mm THICK COMPRESSIBLE MATERIAL BEFORE PLACING CONCRETE IN LIEU OF SLEEVE.

3. FOR UTILITIES BELOW FOOTING WHERE CONCRETE ENCASEMENT IS NOT FEASIBLE, DESIGN PIPE AND PIPE JOINTS TO ADEQUATELY RESIST ALL SUPERIMPOSED LOADS INCLUDING SOIL SURCHARGE PRESSURES.

PLAN AT CORNER PLAN AT INTERSECTION

NOTE:

1. WHERE THREE OR MORE BARS OCCUR, MIDDLE BAR(S) SHALL BE TREATED

AS INNER FACE BAR.

2. TRANSVERSE BARS NOT SHOWN FOR CLARITY.

BARS (TYPICAL)

0" BETWEEN

TYPICAL FOOTING

REINFORCEMENT

CENTERLINE OF COLUMN AND

FOOTING UNLESS OTHERWISE NOTED

12mm PREMOLDED JOINT FILLER AT IJ

ALL AROUND COLUMN (TYPICAL)ANCHOR ROD AND BASE PLATE

CONCRETE SLAB-ON-GRADE.

CONTINUE SLAB CONTRACTION

JOINTS TO SLAB EDGE AT FACE

OF COLUMN

SLAB

REINFORCEMENT

COLUMN FOOTING

SEE PLAN

TOP OF SLAB

-1800

TOP OF FOOTING

D E

P

TH

WIDTH/LENGTH

CONCRETE INFILL, PLACE

CONCRETE AFTER ANCHOR RODS

HAVE BEEN INSPECTED

GROUND FLOOR

CONDUIT, SEE ELECTRICAL

PRECAST WALL

FLOOR SLAB

FLOOR SLAB

FILL OPENING WITH GROUT

AFTER INSTALLING CONDUIT

MAX WIDTH 300mm

O P

E N

SLEEVE OPENING, COORDINATE

WITH ELECTRICAL

FACE OF EQUIPMENT

FINISH GRADE, SEE CIVIL

10M @ 300 EACH WAY

(1) 10m CONTINUOUS BOTTOM

CONCRETE PAD

POROUS FILL,

SEE S-001

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

F O

U N

D A

T

IO

N D

E T

A

IL

S

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-501

14157114

1838720

COLUMN FOOTING SCHEDULE

MARK

DIMENSIONS

REINFORCING STEELWIDTH LENGTH DEPTH

CF 2500 2500 2500 800 (9)25M EACH DIRECTION TOP AND BOTTOM

WALL FOOTING SCHEDULE

MARK

DIMENSIONS

REINFORCINGWIDTH DEPTH

WF900 900 300 (3)15M CONTINUOUS BOTTOM WITH 15M TIES AT 300 ON CENTER

WF900B 900 450 (3)15M CONTINUOUS TOP & BOTTOM WITH 15M TIES AT 300 ON CENTER

WF1000 1000 450 (4)20M CONTINUOUS BOTTOM WITH 20M TIES AT 300 ON CENTER

WF2100 2100 450 (7)20M CONTINUOUS BOTTOM WITH 20M TIES AT 300 ON CENTER TOP AND BOTTOM

NOT TO SCALE

C3

CONTINUOUS FOOTING CONSTRUCTION JOINT

NOT TO SCALE

B3

TYPICAL FOOTING DETAILS

NOT TO SCALE

A1

TYPICAL FOOTING DETAILS

NOT TO SCALE

C4

CONTINUOUS REINFORCING AT CORNERS AND INTERSECTIONS

NOT TO SCALE

B1

TYPICAL FOOTING DETAILS

NOT TO SCALE

A4

TYPICAL OPENING AT CONDUIT

NOT TO SCALE

B4

EXTERIOR EQUIPMENT PAD

A

M E

N D

M E

N T

3/

/2

R E

V

IS

E D

S E

C T

IO

TOP OF FOOTING

TOP OF WALL

HEADER REINF.

10M CORNER BARS

900 LONG TYP

WALL CONNECTION TO FOOTING

WALL PANEL CONNECTIONS

INSIDE FACE

OUTSIDE FACE

15M @300 HORIZ EF

15M @300 VERT EF

WELDED WIRE AS REQ'D FOR

TEMP AND SHRINKAGE

INSULATION

15M @300 HORIZ EF

15M @300 VERT EF

CAULKING AND

BACKER ROD

EMBED PLATE W/WHS

ANGLE

HYDROPHOLIC WATER STOP

BELOW GRADE, EXTEND

300MM ABOVE GRADE

(2) 10M DBE BARS EACH SIDE

9.5mm CONNECTION PLATE

EMBED ANGLE

CAULKING

HYDROPHOLIC WATER STOP

BELOW GRADE, EXTEND

300MM ABOVE GRADE

16 GAUGE CONT

BENT PLATE

#8 SCREWS SELF DRILLING

CONCRETE WALL

L100X100X6

STEEL DECK

6.5mm CONT BENT

PLATE 100X100

100mm METAL

STUD @ 400 OC

CONCRETE WALL

STUD TRACK

9.5mm BENT CONT

BENT PLATE 100X100

100mm METAL

STUDS @ 400 OC

METAL DECK

METAL DECK/

STEEL TUBE

FURRING CHANNELS,

SEE ARCH

STUD TRACK

SEE PLAN

COORDINATE WITH ARCH

ROOF BEAM

ROOF DECK

HA150X150X8 TYP

SLAB-ON-GRADE

12X250X150 BASE PLATE

W/ (2) 20mm POST

INSTALLED ANCHORS

TYP

NOTE:

1. COORDINATE LOCATION WITH LADDER AND DOORS, SEE ARCH.

2. ENSURE BEAM SUPPORTS AND BASE PLATES FIT WITHIN INTERIOR WALL

TYP

TYP

HA150X150X8

L125X125X8 150 LONG W/ 20Ø THRU BOLT

PROVIDE VERTICAL SLOTTED HOLE

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

PM/DM

BRANCH MANAGER

DES PROD DIR

FIRE PROTECTION ENGINEER

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

DES DRW CHK

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 03 MARCH 2024

AS NOTED

A T

LA

N

TI

C

P

LA

N N

IN

G

, D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N N

O R

FO

LK

, V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D A

T L A

N T

IC

DSN

01/15/2026

D. EVANS VIA EMAIL

C U s e rs

\m a tt h e w .w

.w ild e \D o c u m e n ts \P

R s tr u c t_ m a tt h e w .w

.w ild e m a tt h e w

.w .w ild e

.r v t

LMMMWW MWW

MJD/ATP

RLS

JTW

J O

IN

T

M A

R

IT

IM

E

F A

C

IL

IT

Y

W A

L L D

E T

A

IL

S

V A

R

IO

U S

L O

C A

T

IO

N S

V A

R

IO

U S

L O

C A

T

IO

N S

S-504

14157117

1838720

NOT TO SCALE

A1

TYPICAL WALL REINFORCEMENT AT OPENINGS AND EDGES

NOT TO SCALE

D1

TYPICAL 450mm WALL SECTION

NOT TO SCALE

C1

TYPICAL 250mm WALL SECTION

A. REFER TO PRECAST CONCRETE NOTES ON S-001 AND LOADING ON S-002.

B. TYPICAL REINFORCEMENT AND CONNECTIONS SHOWN ARE THE MINIMUM

REQUIRED, PROVIDE ADDITIONAL REINFORCEMENT AS REQUIRED BY

PRECAST MANUFACTURERS DESIGN AT NO ADDITIONAL COST.

C. SIGNIFICANT DEVIATION FROM THE TYPICAL DETAILS MUST BE APPROVED

BY CONTACTING OFFICER.

SHEET NOTES

NOT TO SCALE

D2

WALL CORNERS DETAILS

NOT TO SCALE

C2

WALL CONNECTION

NOT TO SCALE

A3

ROOF OVERHANGS

1 : 10 B4

LADDER SUPPORT/DOOR JAMBS

A

M E

N D

M E

N T

3/

/2

R E

V

IS

E D

S E

C T

IO

A-101

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

WORK KEYNOTES - FLOOR PLAN WORK KEYNOTES - ROOF PLANWORK KEYNOTES - REFLECTED CEILING PLAN

A-105

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

A1 FLOOR PLAN

A-606

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

DOOR SCHEDULE

MARK

W HT THK

SIZE

MATL

DOOR

TYPE GLZ

DOOR

MATL

FRAME

TYPE GLZ

HEAD JAMB THRESHOLD

DETAILS

FRAME

FIRE

RATING

(MIN.)

SET

NO KEYSIDE

RM NO

HARDWARE

NOTES MARK

LOUVER SCHEDULE

MARK ON DWGS DESCRIPTION BOTTOM OF LOUVER

ROUGH OPENING

GLAZING SCHEDULE

MARK ON DWGS DESCRIPTION

A2 LOUVER TYPES

B1 DOOR TYPES B2 DOOR TYPES

DOOR SCHEDULE NOTES

SCHEDULE ABBREVIATIONS

GENERAL DOOR NOTES

F-001

LEGEND:

PUMP SCHEDULE

SPRINKLER SYSTEM DESIGN DATA

A1 ZONE CONTROL VALVE ASSEMBLY

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

A

TL

A N

TI

C

B2 FIRE SPRINKLER RISER

FIRE ALARM GENERAL NOTES:

FA101

SHEET KEYNOTES

A1 FIRE ALARM FLOOR PLAN A3

FIRE ALARM PUMP ROOM 113

JO

IN

T M

A R

IT

IM

E F

A C

IL

IT

Y

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R