Attachment J2 - Drawings 1245.pdf
PDF 27 MB Posted
- Attached to
- Solicitation N4008526R0187 MULTIPLE BARRACKS RENOVATION AT SOUTH CAROLINA MARINE CORPS BASES
- Solicitation number
- N4008526R0187
About this file
This file is a comprehensive set of architectural and engineering drawings for Repair Phase 4 BEQ Building 1245G (BE1813M) at Marine Corps Air Station Beaufort, South Carolina, issued September 8, 2023, under contract N40085-18-D-0616. The drawing package includes 53 sheets covering civil, structural, architectural, interior, fire protection, mechanical, and electrical disciplines for a barracks renovation project.
The civil work scope encompasses site demolition and erosion control, including removal of storm drain lines, concrete sidewalks, and asphalt pavement, followed by installation of new drainage infrastructure with 6" to 15" HDPE and RCP storm piping, concrete sidewalks, and pavement restoration. Site work requires compliance with South Carolina Department of Health and Environmental Control (SCDHEC) sediment and erosion control standards, installation of silt fence and inlet protection devices, and permanent stabilization with sodding. Environmental conditions include PFAS-contaminated in-situ material requiring contained backfill in place, potential asbestos-containing materials in vaults requiring wet methods and negative pressure containment, and alligator presence in storm water outfalls. The structural work involves repair of first-floor column bases, removal of existing C-steel plates at walkway edges on second and third floors, creation of 4"x4" openings in CMU walls for drainage through ungrouted cells, and removal of caulking at existing WT beams. Key notes indicate Building 1245G shall remain unoccupied during construction, while Buildings 1244F, 1246H, and 1247I must remain accessible and occupied, with Building 1247I requiring continuous laundry facility access. The project requires contractor verification of existing utility locations through licensed surveyors and utility locate companies, with mandatory notification to MCAS and coordination with local service providers including Comcast, Dominion Energy, CenturyLink, Hargray Communications, and BJWSA.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VAIGNEUR.CHRISTOPHER.
L.1264998332
Digitally signed by
VAIGNEUR.CHRISTOPHER.L.1264998332
Date: 2023.09.26 08:54:45 -04'00'
LANOIE.RONALD.L.1011923
Digitally signed by
LANOIE.RONALD.L.1011923352
Date: 2023.09.26 13:07:36 -04'00'
CRAFT.RICHARD.S.10585
99340
Digitally signed by
CRAFT.RICHARD.S.1058599340
Date: 2023.09.27 07:32:16 -04'00'
RAMIREZ.PHILIP.JOHN.139558
Digitally signed by
RAMIREZ.PHILIP.JOHN.1395586064
Date: 2023.09.26 11:12:01 -04'00'
WEBB.OWEN.H.
1229842990
Digitally signed by
WEBB.OWEN.H.1229842990
Date: 2023.09.27 07:37:25 -04'00'
GATES.JEREMY.B
RYAN.1172057701
Digitally signed by
GATES.JEREMY.BRYAN.117205
Date: 2023.09.27 15:40:45 -04'00'
THE DRAWINGS IN THIS SET ARE A STAND ALONE
PACKAGE. THE ADDITIONAL PACKAGE DESIGNATIONS
BELOW ARE FOR INFORMATION ONLY:
A. REPAIR PHASE 4 BEQ BUILDING 1244F (BE1812M)
AND 1247I (BE1815M)
B. REPAIR PHASE 4 BEQ BUILDING 1245G (BE1813M)
C. REPAIR PHASE 4 BEQ BUILDING 1246H (BE1814M)
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-O
CT-2
www.cems-ae.com | PM: Dave Yensan | Project: 18152T | 843.875.3637
SHEET
SIZE
ISSUE DATE:
F
SCALE: OF
REVISIONS
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS AIR STATION
BEAUFORT, S.C.
T.O. #
CONSTR. CONTR. NO.:
MACC.
CODE IDENT. NO. N A V F A C DRAWING NO.
IF SHEET IS LESS THAN (30"x42") IT IS A
REDUCED PRINT; SCALE ACCORDINGLY
P.W. DWG. NO.
DRAWN BY
CHECKED BY
SUPERVISOR
APPROVED DATE
PUBLIC WORKS OFFICER
NATURAL RESOURCES & ENVIRONMENTAL AFFAIRS
SAFETY DEPARTMENT
FIRE DEPARTMENT
PHYSICAL SECURITY
PUBLIC WORKS SUPERVISOR
HQMC PROJ. NO.:
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
08 SEPT 2023
M. JOHANNES
D. VON TERSCH
G-002B
D. VON TERSCH
INDEX OF DRAWINGS - BLDG 1245G
REPAIR PHASE 4 BEQ BUILDING 1245G
(BE1813M)
N40085-18-D-0616
28456
INDEX OF DRAWINGS - BLDG 1245G
# OF
TOTAL P.W.#
SHEET
NO. SHEET TITLE
GENERAL
1 28455 G-001 COVER SHEET
2 28456 G-002B INDEX OF DRAWINGS - BLDG 1245G
CIVIL
3 28457 C-001B LEGEND AND GENERAL NOTES
4 28458 C-002B GENERAL NOTES
5 28459 VF101B EXISTING TOPOGRAPHIC SURVEY
6 28460 CD101B DEMOLITION / EROSION CONTROL PLAN
7 28461 CS101B SITE PLAN
8 28462 C-501B EROSION CONTROL DETAILS
9 28463 C-502B DETAILS
10 28464 C-503B DETAILS
STRUCTURAL
11 28465 S-001 GENERAL NOTES AND DESIGN LOADS
12 28466 S-002 SPECIAL INSPECTIONS AND NOTES
13 28467 S-101B FIRST, SECOND AND THIRD FLOOR PLANS - BLDG 1245G
14 28468 S-102B ROOF AND CEILING FRAMING PLANS - BLDG 1245G
15 28469 S-301 DETAILS AND SECTIONS
16 28470 S-302 SECTIONS
17 28471 S-401 ENLARGED STAIR PLAN AND SECTIONS
18 28472 S-402 ENLARGED STAIR PLAN AND SECTIONS
19 28473 S-501 TYPICAL DETAILS
ARCHITECTURAL
20 28474 A-001 ABBREVIATIONS, SYMBOLS AND LEGENDS
21 28475 A-002 GENERAL NOTES
22 28476 AD101B DEMOLITION FIRST, SECOND AND THIRD FLOOR PLANS -
BLDG 1245G
23 28477 AD102B DEMOLITION ATTIC AND ROOF PLANS - BLDG 1245G
24 28478 AD103B DEMOLITION FIRST, SECOND AND THIRD FLOOR
REFLECTED CEILING PLANS - BLDG 1245G
25 28479 AD201B DEMOLITION EXTERIOR ELEVATIONS - BLDG 1245G
26 28480 AD401 TYPICAL DEMOLITION ENLARGED SLEEPING ROOM
PLANS
27 28481 AD901 DEMOLITION PHOTOS AND DETAIL
28 28482 A-101B FIRST, SECOND AND THIRD FLOOR PLANS - BLDG 1245G
29 28483 A-102B ATTIC AND ROOF PLANS - BLDG 1245G
30 28484 A-103B FIRST, SECOND AND THIRD FLOOR REFLECTED CEILING
PLANS - BLDG 1245G
31 28485 A-201B EXTERIOR ELEVATIONS - BLDG 1245G
32 28486 A-301 SECTIONS
33 28487 A-401 ENLARGED SLEEPING ROOM PLANS
34 28488 A-501 DETAILS
35 28489 A-502 DETAILS
36 28490 A-601 FINISH SCHEDULE AND CABINET DETAILS
INTERIORS
37 28491 I-001 INTERIORS GENERAL NOTES AND ABBREVIATIONS
FIRE PROTECTION
38 28492 F-101B FIRST, SECOND AND THIRD FLOOR SUPPRESSION PLAN
-BLDG 1245G
MECHANICAL
39 28493 M-001 LEGEND, ABBREVIATIONS, AND GENERAL NOTES
40 28494 M-101B FIRST, SECOND, AND THIRD FLOOR PLANS - BLDG
1245G
41 28495 M-401 ENLARGED PLANS
42 28496 MP402 TYPICAL SLEEPING ROOM PLAN, ABBREVIATIONS,
LEGEND AND SCHEDULE
43 28497 M-501 SECTIONS AND ENLARGED PLANS
44 28498 M-601B SCHEDULES - BLDG 1245G
45 28499 M-701 CONTROLS LEGEND AND ABBREVIATIONS
46 28500 M-702 CONTROLS
47 28501 M-703 CONTROLS
ELECTRICAL
48 28502 E-001 GENERAL NOTES, LEGENDS AND MOUNTING HEIGHTS
49 28503 E-101B FIRST, SECOND AND THIRD FLOOR PLANS - BLDG 1245G
50 28504 E-102B ATTIC AND ROOF PLANS - BLDG 1245G
51 28505 E-401 ENLARGED PLAN
52 28506 E-501 LIGHTING SCHEDULES AND DETAILS
53 28507 E-502 DETAILS
TOTAL: 53
SYM. DESCRIPTION DATE APP.
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-O
CT-2
J. BARNES
C-001B
D. FARLEY
LEGEND AND GENERAL NOTES
C. MOORING
SHEET
SIZE
F
SCALE: AS NOTED OF
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS AIR STATION
BEAUFORT, S.C.
T.O. #
CONSTR. CONTR. NO.:
MACC.
CODE IDENT. NO. N A V F A C DRAWING NO.
IF SHEET IS LESS THAN (34"x22") IT IS A
REDUCED PRINT; SCALE ACCORDINGLY
P.W. DWG. NO.
DRAWN BY
CHECKED BY
SUPERVISOR
APPROVED DATE
PUBLIC WORKS OFFICER
NATURAL RESOURCES & ENVIRONMENTAL AFFAIRS
SAFETY DEPARTMENT
FIRE DEPARTMENT
PHYSICAL SECURITY
PUBLIC WORKS SUPERVISOR
HQMC PROJ. NO.:
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
N40085-18-D-0616
REVISIONS
SYM. DESCRIPTION DATE APP.
www.cems-ae.com | Summerville, SC | Wilmington, NC | 843.875.3637
REPAIR PHASE 4 BEQ BUILDING 1245G
(BE1813M)
ISSUE DATE: 08 SEPT 2023
CIVIL LEGEND
EXISTING
BUILDING OUTLINE
CONTOUR25
SANITARY SEWER (REC DRAWING)SS DATUR
STORM DRAIN
UNDERGROUND ELECTRICAL
(REC DRAWING)UE DATUR
UNDERGROUND COMMUNICATIONS
(REC DRAWING)
WATER LINE
SANITARY SEWER
UNDERGROUND COMMUNICATIONS
UNDERGROUND ELECTRICAL
TU DATUR
HIGH PRESSURE STEAM (REC DRAWING)ST DATUR
UNKNOWN UNDERGROUND UTILITYUNKx UNKx
WATER LINE (REC DRAWING)W DATUR W DATUR
STORM DRAIN (REC DRAWING)SD DATUR
CONCRETE CURB AND GUTTER
EDGE OF PAVEMENT / SIDEWALK
SCO
BENCHMARK / CONTROL POINT
COMMUNICATIONS MANHOLE
DRAINAGE MANHOLE
ELECTRIC TRANSFORMER
FIRE HYDRANT
ELECTRICAL MANHOLE
LIGHT POLE
TELEPHONE PEDESTAL
TELEVISION PEDESTAL
ELECTRICAL DEVICE
FENCE
GAS LINE
OVERHEAD ELECTRICAL
POWER POLE
WATER VALVE
BOLLARD
DROP INLET
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE
GUY WIRE
SIGN
TREE
NEW
CONCRETE SIDEWALK
ASPHALT PAVEMENT
STORM DRAIN CLEANOUT
DOWNSPOUT
LIMITS OF CONSTRUCTION
LIMITS OF DISTURBANCE
TO BE REMOVED
SILT FENCE
INLET PROTECTION
TREE PROTECTION
WHEELSTOP
BEQ 1245G
COORDINATE TABLE
POINT
NORTHING
227539.303
EASTINGLOCATION /
BLDG CORNER
NORTHWEST
NORTHEAST
SOUTHEAST
SOUTHWEST
2087242.460
227539.671 2087290.609
227362.276 2087291.964
227361.908 2087243.816
SURVEY LEGEND
EXISTING
BUILDING OUTLINE
CONTOUR25
SANITARY SEWER (REC DRAWING)SS DATUR
STORM DRAIN
UNDERGROUND ELECTRICAL
(REC DRAWING)UE DATUR
UNDERGROUND COMMUNICATIONS
(REC DRAWING)
WATER LINE
SANITARY SEWER
UNDERGROUND COMMUNICATIONS
UNDERGROUND ELECTRICAL
TU DATUR
HIGH PRESSURE STEAM (REC DRAWING)ST DATUR
UNKNOWN UNDERGROUND UTILITYUNKx UNKx
WATER LINE (REC DRAWING)W DATUR W DATUR
STORM DRAIN (REC DRAWING)SD DATUR
CONCRETE CURB AND GUTTER
EDGE OF PAVEMENT
SCO
BENCHMARK / CONTROL POINT
COMMUNICATIONS MANHOLE
DRAINAGE MANHOLE
ELECTRIC TRANSFORMER
FIRE HYDRANT
ELECTRICAL MANHOLE
LIGHT POLE
TELEPHONE PEDESTAL
TELEVISION PEDESTAL
ELECTRICAL DEVICE
FENCE
GAS LINE
OVERHEAD ELECTRICAL
POWER POLE
WATER VALVE
BOLLARD
DROP INLET
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE
GUY WIRE
SIGN
TREE
CONCRETE SIDEWALK
ASPHALT PAVEMENT
WHEELSTOP
DOWNSPOUT
STORM DRAIN = SD
MANHOLE = MH
TYP. = TYPICAL
REINFORCED CONCRETE PIPE = RCP
DUCTILE IRON PIPE = DIP
HIGH DENSITY POLYETHYLENE = HDPE
ABBREVIATIONS
LAND DISTURBANCE NOTES
1. THE PROJECT AREA IS APPROXIMATELY 7.8 ACRES AS SHOWN BY THE LIMITS OF
CONSTRUCTION. DISTURBED AREA IS APPROXIMATELY 0.6 ACRES AS SHOWN BY SILT
FENCE UNLESS OTHERWISE SHOWN BY THE LIMITS OF DISTURBANCE.
2. ALL AREAS DISTURBED BY CONSTRUCTION OPERATIONS AND NOT PAVED SHALL BE
SODDED / GRASSED. PROVIDE PERMANENT SODDING AND TEMPORARY SEEDING PER
COVERAGE REQUIREMENTS, SEE SHEET C-002B.
3. THE PROPERTY IS LOCATED WITHIN BEAUFORT COUNTY, SOUTH CAROLINA LOCATED
ON BEAUFORT USGS QUAD SHEET AND OUTFALLS TO BRICKYARD CREEK.
4. THIS DEVELOPED PROPERTY LIES IN ZONE X PER FIRM COMMUNITY NO. 450025, PANEL
007D, DATED EFFECTIVE DATE SEPTEMBER 29, 1986.
5. THE DISTURBED ACREAGE IS 0.6 ACRES, OF WHICH NO NEW IMPERVIOUS AREA OR
BUILT UPON AREA (BUA) WILL BE CONSTRUCTED IN PROJECT AREA; THEREFORE, DOES
NOT REQUIRE SCDHEC PERMITTING FOR SEDIMENT & EROSION CONTROL AND
STORMWATER, ONLY NOTIFICATION LETTERS. A COASTAL AREA MANAGEMENT ACT
(CAMA) MAJOR DEVELOPMENT PERMIT IS NOT REQUIRED.
6. SOUTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL (SCDHEC)
PERMITTING SUBMISSION AND ACQUISITION SHALL BE HANDLED BY MCAS BEAUFORT,
NATURAL RESOURCES AND ENVIRONMENTAL AFFAIRS OFFICE WITH ASSISTANCE FROM
ENGINEER OF RECORD (EOR).
TRANSF. = TRANSFORMER
INVERT ELEVATION = IE
ELEV. = ELEVATION
FRAME (RIM ELEVATION) = FR
INSTALLATION ACCESS
1. CONTRACTOR AND SUB-CONTRACTOR PERSONNEL ARE REQUIRED TO FOLLOW THE
PROCEDURES FOR BASE ACCESS AND DBIDS PROCESS TO ACCESS THE BASE.
DEMOLITION NOTES
1. UNLESS NOTED OTHERWISE, DEMOLITION WORK ENTAILS COMPLETE REMOVAL OF THE
ITEMS OR STRUCTURES IN THEIR ENTIRETY. REPAIR, REMOVAL AND REPLACEMENT OF
PAVEMENT AND SITE ITEMS SHOWN IS THE MINIMUM AMOUNT REQUIRED TO COMPLETE
THE PROJECT. ALL DEMOLISHED MATERIAL SHALL BE REMOVED FROM THE INSTALLATION.
2. SAW CUT AND REMOVE ALL EXISTING PAVEMENT AS NOTED ON PLANS. PROVIDE NEAT
AND CLEAN JOINTS AT PAVEMENT TO REMAIN. REMOVE AND REPLACE THE FULL SECTION.
3. ALL DEPRESSIONS RESULTING FROM DEMOLITION ACTIVITIES SHALL BE FILLED &
COMPACTED WITH SUITABLE SOILS TO EXISTING GRADE AND SLOPED FOR POSITIVE
DRAINAGE. OFFSITE BORROW NECESSARY FOR THE CONSTRUCTION OF THIS PROJECT
SHALL BE PROVIDED BY THE CONTRACTOR.
4. AFTER GRADING ACTIVITY HAS BEEN COMPLETED, THE CONTRACTOR SHALL PLACE
NECESSARY TOPSOIL AND SOD AS SPECIFIED ON THE SHEETS IN ALL DISTURBED
LOCATIONS NOT TO BE PAVED.
1. PLACE SCDHEC LAND DISTURBANCE NOTIFICATION, APPROVED PLANS AND THE ON-SITE SWPPP
(OS-SWPPP) AT A LOCATION ON THE SITE.
2. BEFORE LAND DISTURBING ACTIVITIES, THE LOCAL EQC MUST BE NOTIFIED, A DIG PERMIT SHALL
BE SUBMITTED TO MCAS WITH ADEQUATE NOTICE, AND A SWPPP PRECONSTRUCTION MEETING
PERFORMED.
3. INSTALL TEMPORARY CONSTRUCTION CHAIN LINK FENCING UPON APPROVAL BY CONTRACTING
OFFICER AND MCAS BEAUFORT FEAD.
4. INSTALL SILT FENCE, INLET PROTECTION AND TEMPORARY GRAVEL CONSTRUCTION ENTRANCE
WHERE INDICATED ON THE PLANS OR AS NECESSARY. DISTURBANCE SHOULD BE MINIMAL AS
NECESSARY TO INSTALL MEASURES.
5. ESTABLISH PROPER CONSTRUCTION LIMITS TO LIMIT NON-CONSTRUCTION PERSONNEL FROM
WORK AREA.
6. REMOVE ALL CONCRETE SIDEWALKS AND ANY SITE STRUCTURES / FEATURES SPECIFIED TO BE
REMOVED ON THE PLANS.
7. TRENCHING AND INSTALLATION OF NEW STORM DRAINAGE LINES AND STRUCTURES MAY BEGIN.
SEQUENCE SHALL BE DICTATED BY WHETHER PRODUCTS / SUBMITTALS HAVE BEEN APPROVED.
SEE MECHANICAL PLANS FOR MORE DETAILS AND IMPROVEMENTS WITHIN 5 FEET OF BUILDINGS.
8. FILL AND COMPACT ALL TRENCHES.
9. INSTALL ALL NEW CONCRETE SIDEWALK.
10. COMPLETE FINISHED GRADING OPERATIONS AND PAVEMENT REPAIRS.
11. INITIATE PERMANENT VEGETATIVE STABILIZATION MEASURES.
12. REMOVE ACCUMULATED SEDIMENT AND MAINTAIN SEDIMENT DEVICES UNTIL SITE HAS BEEN
STABILIZED.
13. REMOVE SEDIMENT DEVICES ONCE SITE HAS BEEN STABILIZED AND GIVEN APPROVAL BY
GOVERNMENT.
14. SUBMIT NOTICE OF TERMINATION OF SCDHEC AND MEET ALL OF THE LAND DISTURBANCE
PERMIT REQUIREMENTS.
1. SEE SHEET C-501B THROUGH C-503B FOR CIVIL DETAILS.
2. ALL DISTURBED AREAS TO BE GRADED FOR POSITIVE DRAINAGE TO STORM INLETS.
3. CONTRACTOR WILL BE RESPONSIBLE FOR ADDITIONAL REMOVAL AND REPLACEMENT OF
CONCRETE PAVEMENT AS NECESSARY TO CONSTRUCT THE PROJECT. PAVEMENT REMOVAL
AND REPLACEMENT SHOWN IS THE MINIMUM AMOUNT REQUIRED TO CONSTRUCT THE PROJECT.
4. THE LOCATION, SIZES, AND DEPTHS OF EXISTING UTILITIES, INCLUDING SERVICE LATERALS, AND
DRAINAGE STRUCTURES SHOWN ON THE PLANS ARE APPROXIMATE ONLY. THE CONTRACTOR
SHALL VERIFY THE EXACT LOCATION, SIZES, AND DEPTHS OF UNDERGROUND UTILITIES AT
LEAST 48 HOURS PRIOR TO CONSTRUCTION WHETHER SHOWN ON PLANS OR NOT, AND TO
PROTECT THE SAME DURING CONSTRUCTION.
5. THE CONTRACTOR IS HEREBY CAUTIONED THAT ALL SITE FEATURES SHOWN HEREON ARE
BASED ON FIELD OBSERVATIONS BY THE SURVEYOR AND BY INFORMATION PROVIDED BY
OTHERS. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE AND WILL
BE RESPONSIBLE FOR FIELD VERIFICATION PRIOR TO CONSTRUCTION.
6. CONTRACTOR TO COORDINATE LOCATION/MARKING OF EXISTING SITE UTILITIES IN AREAS
WHERE WORK IS CONDUCTED, AND ENSURE THEY ARE TURNED OFF PROPERLY BEFORE
BEGINNING CONSTRUCTION.
7. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE DONE TO ANY
NEW AND EXISTING SITE ITEMS IN THE EXECUTION OF HIS WORK UNDER THIS SECTION.
8. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND BE
PREPARED TO ADEQUATELY CARE FOR AND SAFEGUARD HIMSELF AND THE GOVERNMENT FROM
DAMAGE. CONTRACTOR TO VERIFY EXISTING UTILITY (STORM DRAIN, WATER LINE, ETC...) LINE
SIZES AND NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES BEFORE ORDERING
MATERIALS. ADVANCED PERMISSION FROM THE INSTALLATION FOR PHOTOGRAPHY TO
DOCUMENT EXISTING CONDITIONS PRIOR TO START OF ANY WORK IS REQUIRED.
9. PRIOR TO STORM DRAIN LINE INSTALLATION, THE CONTRACTOR MUST VERIFY ELEVATIONS OF ALL THE EXISTING UTILITIES AT ALL UTILITY CROSSINGS. IF CONFLICT EXISTS, CONTRACTOR
SHALL RELOCATE UTILITIES AS NECESSARY AND NOTIFY THE CONTRACTING OFFICER (COR).
CONTRACTOR TO TAKE EVERY MEASURE TO LOCALIZE OUTAGES TO BUILDINGS. COORDINATE
ALL NECESSARY OUTAGES WITH COR.
CONSTRUCTION SEQUENCE NOTES
SCDHEC NOTES
1. STORMWATER, SEDIMENT AND EROSION CONTROL MEASURES SHALL BE IN PLACE FOR
THE DURATION OF SITE WORK IN ACCORDANCE WITH THE DRAWINGS. MEASURES SHALL
BE ESTABLISHED PRIOR TO SITE DISTURBANCE (TOTALING 0.6 ACRES) AND MAINTAINED
THRU STABILIZATION CLOSEOUT.
2. I HAVE PLACED MY SIGNATURE AND SEAL ON THE DESIGN DOCUMENTS SUBMITTED
SIGNIFYING THAT I ACCEPT RESPONSIBILITY FOR THE DESIGN OF THE SYSTEM.
FURTHER, I CERTIFY TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THE DESIGN IS
CONSISTENT WITH THE REQUIREMENTS OF TITLE 48, CHAPTER 14 OF THE CODE OF
LAWS OF SC, 1976 AS AMENDED, PURSUANT TO REGULATION 72-300 ET SEQ. (IF
APPLICABLE), AND IN ACCORDANCE WITH THE TERMS AND CONDITIONS OF SCR100000.
BUILDING COORDINATE POINT
(SHOWN ON CS101B AND TABLE BELOW)
17.7'
18.25 SPOT ELEVATION
SPOT ELEVATION
GENERAL NOTES
18.25
28457
10/4/2023
C-002B
D. FARLEY
GENERAL NOTES
C. MOORING
SHEET
SIZE
F
SCALE: AS NOTED OF
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS AIR STATION
BEAUFORT, S.C.
T.O. #
CONSTR. CONTR. NO.:
MACC.
CODE IDENT. NO. N A V F A C DRAWING NO.
IF SHEET IS LESS THAN (34"x22") IT IS A
REDUCED PRINT; SCALE ACCORDINGLY
P.W. DWG. NO.
DRAWN BY
CHECKED BY
SUPERVISOR
APPROVED DATE
PUBLIC WORKS OFFICER
NATURAL RESOURCES & ENVIRONMENTAL AFFAIRS
SAFETY DEPARTMENT
FIRE DEPARTMENT
PHYSICAL SECURITY
PUBLIC WORKS SUPERVISOR
HQMC PROJ. NO.:
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
N40085-18-D-0616
REVISIONS
SYM. DESCRIPTION DATE APP.
www.cems-ae.com | Summerville, SC | Wilmington, NC | 843.875.3637
REPAIR PHASE 4 BEQ BUILDING 1245G
(BE1813M)
ISSUE DATE: 08 SEPT 2023
SITE INVESTIGATION NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AN AS-BUILT SURVEY (PERFORMED BY A
SURVEYOR LICENSED IN THE STATE OF SOUTH CAROLINA) OF ALL ABOVE AND BELOW GROUND SITE FEATURES, INCLUDING UTILITIES, WITHIN THE PROJECT SITE AND AREA AFFECTED BY THIS PROJECT SCOPE. SURVEY SHALL CAPTURE ALL UTILITIES AND STRUCTURES. SURVEY SHALL PROPERLY VERIFY THE LOCATION, ELEVATION / DEPTH, RIM, INVERT(S) AND ITEM SIZE(S).
2. THE CONTRACTOR SHALL HIRE A UTILITY LOCATE COMPANY TO LOCATE AND MARK ALL SUBSURFACE UTILITIES OR OTHER NOTEWORTHY ITEMS FOR AWARENESS AND TO ENSURE PROTECTION IN THE VICINITY OF
EARTHWORK, DEMOLITION, REPAIR AND CONSTRUCTION.
3. ALL EXISTING UTILITIES ARE SHOWN IN AN APPROXIMATE LOCATIONS PER GIS DATA, LIDAR DATA, AND INSTALLATION RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY LOCATIONS, SIZES, AND DEPTHS OF ALL EXISTING ABOVE & BELOW GROUND UTILITIES AT LEAST 48 HOURS PRIOR TO THE START OF EARTHWORK, DEMOLITION, REPAIR AND CONSTRUCTION. THE CONTRACTING OFFICER SHALL BE NOTIFIED OF ANY
DISCREPANCIES AFFECTING EXCAVATION, DEMOLITION, REPAIR OR CONSTRUCTION.
4. THE CONTRACTOR SHALL CALL PUPS, 811 OR (888) 721-7877, BEFORE ANY EXCAVATION AND COORDINATE WITH MARINE CORPS AIR STATION (MCAS) ON LOCATING REQUIREMENTS. SOUTH CAROLINA STATE LAW REQUIRES ANY ACTIVITY THAT RESULTS IN THE MOVEMENT OR REMOVAL OF EARTH, ROCK OR OTHER MATERIALS IN OR ON THE GROUND REQUIRES THE EXCAVATOR TO CONTACT THE UTILITY COMPANY OR ONE CALL CENTER WITH ADEQUATE INFORMATION REGARDING THE DIG. EACH EXCAVATOR IS REQUIRED TO WAIT 72-HOURS OR 3
BUSINESS DAYS BEFORE STARTING THE DIGGING WORK.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH UTILITY PROVIDERS (AS NECESSARY) WITHIN
THE PROJECT AREA. SOME UTILITY CONTACT INFORMATION IS AS FOLLOWS:
COMCAST: 4400 BELLE OAKS DR. CHARLESTON, SC 29405. 843-266-3010
DOMINION ENERGY: PO BOX 1168, BEAUFORT, SC 29901. 843-525-7731
CENTURYLINK: PO DRAWER 1659, BEAUFORT, SC 29902. 843-525-7979
HARGRAY COMMUNICATIONS GROUP, INC: PO BOX 346 BLUFFTON, SC 29910. 843-815-1676
BJWSA: 6 SNAKE RD OKATIE, SC 29909. 843-987-9229.
6. KNOWN UNDERGROUND UTILITY LOCATIONS ARE SHOWN ON THE PLAN. THE CONTRACTOR IS HEREBY NOTIFIED THAT NOT ALL UTILITY LOCATIONS ARE SHOWN AND/OR KNOWN, BUT COULD POSSIBLY BE ENCOUNTERED IN THE AREA OF WORK. ALL UTILITIES ENCOUNTERED SHALL BE PROTECTED DURING EXCAVATION, DEMOLITION, REPAIR AND CONSTRUCTION UNLESS OTHERWISE STATED TO BE REMOVED.
ENVIRONMENTAL NOTES
1. IF ANY SUSPECTED ARTIFACTS ARE DISCOVERED DURING GROUND DISTURBING ACTIVITIES, ALL WORK
SHOULD STOP AND NREAO (AND PROJECT MANAGER / CONTRACTING OFFICER) SHOULD BE NOTIFIED
IMMEDIATELY.
2. ALLIGATORS HAVE BEEN KNOWN TO INHABIT VARIOUS STORM WATER OUTFALLS. WORKERS SHOULD BE AWARE OF THEIR POTENTIAL PRESENCE. IF ENCOUNTERED, CONTACT NREAO PERSONNEL IMMEDIATELY FOR
ALLIGATOR REMOVAL/RELOCATION.
3. AREA IN-SITU MATERIAL IS KNOWN TO BE CONTAMINATED WITH PER- AND POLYFLUOROALKYL SUBSTANCES (PFAS). EXCAVATED EARTHWORK SHALL BE BACKFILLED IN PLACE. ALTERNATIVELY, CONTAMINATED MATERIAL SHALL BE CONTAINED, ENCLOSED, AND FOLLOW REQUISITE STATE AND FEDERAL REQUIREMENTS
FOR REMOVAL AND DISPOSAL.
4. BENTONITE CLAY AND/OR OTHER MATERIALS USED FOR DIRECTIONAL DRILLING MUST BE REMOVED FROM THE INSTALLATION. FOLLOW REQUISITE STATE AND FEDERAL REQUIREMENTS FOR REMOVAL AND DISPOSAL.
5. THE CONTRACTOR SHALL BE RESPONSIBLE TO ACQUIRE ALL NECESSARY PERMITS PER STATE, FEDERAL REGULATIONS, AND OSHA STANDARDS INCLUDING HAZARDOUS MATERIAL PERMITTING. A COPY OF THE LEAD AND ASBESTOS REPORT MUST BE SUBMITTED TO SCDHEC AT LEAST (10) WORKING DAYS PRIOR TO DEMOLITION WHEN APPLYING FOR A DEMOLITION PERMIT. ALL PERMITS/ RECEIPTS/ INSPECTION DOCUMENTS
SHALL BE COORDINATED WITH MCAS PROGRAM MANAGER, CHRIS DOSHER AT
CHRISTOPHER.DOSHER@USMC.MIL. PROPER LABELING, TRANSPORTING, AND DISPOSAL OF HAZARDOUS
CONTAINING MATERIALS ARE THE RESPONSIBILITY OF THE CONTRACTOR.
6. UNLESS EXPLICITLY STATED, VAULTS SHALL BE CONSIDERED AS POSSIBLE SOURCES OF ASBESTOS CONTAINING MATERIAL. WET METHODS MUST BE EMPLOYED IF VAULT IS NOT ALREADY MOISTENED OR UNDERWATER. DUST SUPPRESSION VIA AMENDED WATER SHALL BE USED AT THE POINT OF DUST GENERATION. HEPA VACUUMS AT THE POINT OF WORK SHALL BE USED TO COLLECT ANY REMAINING AIRBORNE FIBERS. SHOULD THERE BE A CONCERN FOR SIGNIFICANT DUST GENERATION, THE GENERAL SETUP OF VAULTS AND MANHOLES MUST ENABLE THE USE OF NEGATIVE PRESSURE CONTAINMENT. EXPOSURE MONITORING OF AIRBORNE FIBERS MUST BE CONDUCTED. THE MONITORING WILL BE USED TO CREATE A “NEGATIVE EXPOSURE ASSESSMENT” AND WILL DICTATE WHAT THE APPROPRIATE LEVEL OF RESPIRATORY PROTECTION IS. RUN INITIAL AIRBORNE ASBESTOS “EXCURSION” SAMPLES TO DEVELOP A NEGATIVE EXPOSURE ASSESSMENT. UNDER NO CIRCUMSTANCES SHALL PERSONNEL USE COMPRESSED AIR OR OTHER
GASES IN THE VAULTS FOR THE PURPOSE OF “PUSHING” A DEVICE THROUGH THE CONDUIT.
7. ALL DEMOLITION DEBRIS SHALL BE HAULED OFFSITE AND DISPOSED OF OFFSITE AT A FACILITY LICENSED AND PERMITTED TO ACCEPT LIKE MATERIALS, WITH A STATE APPROVED EROSION CONTROL PLAN IN PLACE. ALL MATERIALS SHALL BE TRANSPORTED OFF GOVERNMENT PROPERTY FOR FURTHER PROCESSING BY THE
CONTRACTOR OR OTHER PARTIES IN ACCORDANCE WITH DOD REGULATIONS.
8. HAZARDOUS COMPONENT ABATEMENT FOR MATERIALS SUCH AS ASBESTOS, PETROLEUM DERIVATIVES, LEAD PAINT, PCB LIQUIDS, AND OTHER HAZARDOUS MATERIALS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR WITH A HAZARDOUS WASTE MANAGEMENT PLAN (HWMP) IN PLACE. THE CONTRACTOR SHALL ACQUIRE A COMPETENT/ CURRENT SCDHEC ASBESTOS SUPERVISOR DURING ANY POSSIBLE DISTURBANCE OF ACM TO ASSURE COMPLIANCE FOR BOTH STATE AND FEDERAL REGULATIONS. IF ASBESTOS IS PRESENT OR PRESUMED, THIS PROJECT IS SUBJECT TO SOUTH CAROLINA REGULATION 61-86.1, STANDARDS OF
PERFORMANCE FOR ASBESTOS.
9. THE CONTRACTOR SHALL ABATE, REMOVE, AND MANAGE THE HAZARDOUS MATERIALS IN ACCORDANCE WITH FEDERAL AND LOCAL ENVIRONMENTAL PROTECTION LAWS AND REGULATIONS. THE CONTRACTOR SHALL DETERMINE IF PERSONAL PROTECTIVE EQUIPMENT IS RECOMMENDED OR REQUIRED BASED ON EVALUATIONS OF THE COMPLETED REPORTS. IF PROJECT IS CLASSIFIED BY SCDHEC ASBESTOS STANDARDS AS NESHAP SIZE
PROJECT A SCDHEC LICENSED PROJECT.
10. CONTRACTOR WILL BE REQUIRED BY MCAS TO PROVIDE ASBESTOS PLAN FOR REVIEW AND ACCEPTANCE FROM NREAO WITH SAFETY BEFORE APPLYING FOR PERMIT. ESTABLISH DESIGNATED LIMITS FOR THE ASBESTOS REGULATED WORK AREA WITH THE USE OF RED BARRIER TAPE, CRITICAL BARRIERS AND SIGNS, AND MAINTAIN
ALL OTHER REQUIREMENTS FOR ASBESTOS CONTROL AREA EXCEPT LOCAL EXHAUST.
STANDARD NOTES:
1. IF NECESSARY, SLOPES, WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BE STABILIZED WITH SYNTHETIC
OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING. IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS
BROUGHT TO GRADE.
2. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE
FOURTEEN (14) DAYS AFTER WORK HAS CEASED, EXCEPT AS STATED BELOW.
· WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND
CONDITIONS STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICABLE.
· WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND
EARTH-DISTURBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION
MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE.
3. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED ONCE EVERY CALENDAR WEEK. IF PERIODIC INSPECTION OR OTHER INFORMATION INDICATES THAT A BMP HAS BEEN INAPPROPRIATELY, OR INCORRECTLY, THE PERMITTEE MUST ADDRESS THE NECESSARY REPLACEMENT OR MODIFICATION
REQUIRED TO CORRECT THE BMP WITHIN 48 HOURS OF IDENTIFICATION.
4. PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE ANY SEDIMENTS BEFORE BEING PUMPED BACK INTO THE WATERS
OF THE STATE.
5. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE
REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED.
6. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL
DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAY BE REQUIRED.
7. RESIDENTIAL SUBDIVISIONS REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANS DURING CONSTRUCTION OR OBTAIN APPROVAL OF AN INDIVIDUAL PLAN IN ACCORDANCE WITH S.C. REG. 72-300 ET
SEQ. AND SCR100000.
8. TEMPORARY DIVISION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO
PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR DIVERT SEDIMENT-LADEN WATER TO
APPROPRIATE TRAPS OR STABLE OUTLETS.
9. ALL WATERS OF THE STATE (WOS), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL WOS. A 10-FOOT BUFFER SHOULD
BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS.
10. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN
STORM WATER DISCHARGES.
11. A COPY OF THE SWPPP, INSPECTIONS RECORDS, AND RAINFALL DATA MUST BE RETAINED AT THE CONSTRUCTION SITE OR A NEARBY LOCATION EASILY ACCESSIBLE DURING NORMAL BUSINESS HOURS, FROM THE DATE OF COMMENCEMENT OF CONSTRUCTION ACTIVITIES TO THE DATE THAT FINAL
STABILIZATION IS REACHED.
12. INITIATE STABILIZATION MEASURES ON ANY EXPOSED STEEP SLOPE (3H:1V OR GREATER) WHERE LAND-DISTURBING ACTIVITIES HAVE PERMANENTLY OR TEMPORARILY CEASED, AND WILL NOT RESUME FOR
A PERIOD OF 7 CALENDAR DAYS.
13. MINIMIZE SOIL COMPACTION AND, UNLESS INFEASIBLE, PRESERVE TOPSOIL.
14. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER, AND OTHER WASH WATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE
CONTROL THAT PROVIDES EQUIVALENT OR BETTER TREATMENT PRIOR TO DISCHARGE;
15. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM DEWATERING OF TRENCHES AND EXCAVATED AREAS.
THESE DISCHARGES ARE TO BE ROUTED THROUGH APPROPRIATE BMPS (SEDIMENT BASIN, FILTER BAG, ETC.).
16. THE FOLLOWING DISCHARGES FROM SITES ARE PROHIBITED:
· WASTEWATER FROM WASHOUT OF CONCRETE, UNLESS MANAGED BY AN APPROPRIATE CONTROL;
· WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OILS, CURING
· COMPOUNDS AND OTHER CONSTRUCTION MATERIALS;
· FUELS, OILS, OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND
· MAINTENANCE; AND
· SOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING.
17. AFTER CONSTRUCTION ACTIVITIES BEGIN, INSPECTIONS MUST BE CONDUCTED AT A MINIMUM OF AT LEAST ONCE EVERY CALENDAR WEEK AND MUST BE CONDUCTED UNTIL FINAL STABILIZATION IS REACHED ON ALL
AREAS OF THE CONSTRUCTION SITE.
18. IF EXISTING BMPS NEED TO BE MODIFIED OR IF ADDITIONAL BMPS ARE NECESSARY TO COMPLY WITH THE REQUIREMENTS OF THIS PERMIT AND/OR SC’S WATER QUALITY STANDARDS, IMPLEMENTATION MUST BE COMPLETED BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. IF IMPLEMENTATION BEFORE THE NEXT STORM EVENT IS IMPRACTICABLE, THE SITUATION MUST BE DOCUMENTED IN THE SWPPP AND
ALTERNATIVE BMPS MUST BE IMPLEMENTED AS SOON AS REASONABLY POSSIBLE.
19. A PRE-CONSTRUCTION CONFERENCE MUST BE HELD FOR EACH CONSTRUCTION SITE WITH AN APPROVED ON-SITE SWPPP PRIOR TO THE IMPLEMENTATION OF CONSTRUCTION ACTIVITIES. FOR NON-LINEAR PROJECTS THAT DISTURB 10 ACRES OR MORE THIS CONFERENCE MUST BE HELD ON-SITE UNLESS THE
DEPARTMENT HAS APPROVED OTHERWISE.
3. EROSION CONTROL PLAN
1. GENERAL
A. INSTALL PERMANENT VEGETATIVE COVER AND THE LONG-TERM EROSION PROTECTION MEASURES
OR STRUCTURES AS SOON AS PRACTICAL IN THE DEVELOPMENT PROCESS.
B. PROVIDE FOR HANDLING THE INCREASED RUNOFF CAUSED BY CHANGED SOIL AND SURFACE
CONDITIONS. USE EFFECTIVE MEANS TO CONSERVE EXISTING ON-SITE SOIL INCLUDING THE USE OF
DIVERSION DITCHES, GRASSED WATERWAYS AND STORM SEWERS.
C. PLACE SILT FENCE BARRIERS AT LOCATIONS SHOWN ON PLAN. SILT BARRIERS SHALL BE MAINTAINED
IN PLACE AND IN GOOD CONDITION UNTIL GROUND COVER IS ESTABLISHED.
D. ALL DISTURBED AREAS NOT PAVED SHALL BE GRASSED. USE TEMPORARY PLANT COVER, MULCHING, AND/OR STRUCTURES TO CONTROL RUNOFF AND PROTECT AREAS SUBJECT TO EROSION DURING
CONSTRUCTION.
E. CONTRACTOR SHALL PROVIDE DUMPSTER OF SUFFICIENT SIZE AND NUMBER TO CONTAIN THE SOLID
WASTE GENERATED BY THE PROJECT.
F. CONTRACTOR SHALL FREQUENTLY REMOVE GARBAGE TO MAINTAIN A CLEAN CONSTRUCTION SITE
AND MINIMIZE THE EXPOSURE OF WASTE TO STORM WATER.
A. ALL AREAS WHICH ARE DISTURBED BY THE CONTRACTOR SHALL BE FINAL STABILIZED WITH SOD.
2. GRASS AND COASTAL SEEDING SPECIFICATIONS
TEMPORARY SEEDING (EXCEPT FOR FLIGHTLINE LOCATIONS):
“COOL SEASON”: PLANTED BETWEEN 1 SEPTEMBER AND 3 MARCH
SPECIES RATE
RYEGRASS W/ BERMUDA 90-135 LBS./AC.
CONTRACTOR SHALL ENSURE EFFECTIVE WATERING AND PERIODIC
INSPECTION TO ENSURE APPROPRIATE GROWTH OF GRASS.
SEDIMENT AND EROSION CONTROL NOTES:
28458
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
U E
D
AT
U R
U E
D
AT
U R
U E
D
AT
U R
UE DATURUE DATURUE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR UE DATUR
UE DATUR
W D
ATU
R W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR
SD DATUR
SD DATUR SD DATUR
SD DATUR
SD
D
ATU
R
SD DATURSD DATURSD DATURSD DATUR
SD
D
AT
U
R
SD
D
AT
U R
SD
D
AT
U
R
SD DATUR
W D
ATU
R
W D
ATU
R
W D
ATU
RW DATURW DATUR
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR
ST
D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
W D
AT
U
R W
D
AT
U R
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
U E D
ATU
R
U E D
ATU
R
UE DATUR
TU DATUR
TU DATUR
TU DATUR
TU DATURTU DATURTU DATURTU DATURTU DATURTU DATUR
W D
AT
U
R W
D
AT
U R
W DATURW DATUR
UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR
UE D
ATUR
UE D
ATUR
UE DATUR
UE DATUR
UE D
ATU
R
U E D
ATU
R
UE DATUR UE DATUR UE DATUR
W DATUR W DATUR
TRN #11
N:227546.87 E:2087350.84
ELEV.:16.776
SCO
ST
AI
R S
ST
AI
R S
STAIRS
BR
EE
ZE
W
AY
PA
VI
LI
O
N
ST
AI
R S
STAIRS
BR
EE
ZE
W
AY
HORSESHOE PIT
TRANSF.
CONCRETE
BARRICADE (TYP.)
BIKE
RACK
GRILL
U N
KN
O
W N
VA
LV
E
8"
8"
8"
PARKING
BLOCK (TYP.)
C O
VE
R
ED
W
AL
KW
AY
UNABLE TO FIND
END OF PIPE
COVERED
WALKWAY
TRASH
CAN
TRASH CAN
TRN #13
N:227714.46 E:2087329.40
ELEV.:17.420 SAND VOLLEYBALL
COURT
4" C
PP
DROP INLET
RIM: 15.08'
INV IN: 12.00'
INV OUT: 11.90'
DROP INLET
RIM: 15.34'
INV IN (A): 12.84'
INV IN (B): 13.04'
INV OUT (C): 12.74'
DROP INLET
RIM: 15.89'
INV IN: 13.39'
INV OUT: 13.34'
DROP INLET
RIM: 16.46'
INV IN: 14.21'
INV OUT: 14.11' DROP INLET
RIM: 16.12'
INV IN: 13.77'
INV OUT: 13.72
DRAINAGE MANHOLE
RIM: 17.48'
INV OUT: NO PIPES
DROP INLET
RIM: 15.60'
INV OUT: 15.05'
DROP INLET
RIM: 16.74'
INV OUT: 15.31'
DROP INLET
RIM: 17.25'
INV IN: N/A
INV OUT: N/A
DROP INLET
RIM: 16.88'
INV OUT: 15.68'
DROP INLET
RIM: 16.67'
INV IN: 14.73'
INV OUT: 14.63'
DROP INLET
RIM: 16.42'
INV OUT: 14.95'
SANITARY MANHOLE
RIM: 16.55'
INV IN: 11.20'
INV OUT: 11.05'
SANITARY MANHOLE
RIM: 17.38'
INV IN: 12.74'
INV OUT: 12.67'
SANITARY MANHOLE
RIM: 16.73'
INV IN: 12.08'
INV OUT: 11.93'
SANITARY MANHOLE
RIM: 17.12'
INV OUT: 12.42'
SANITARY MANHOLE
RIM: 16.68'
INV IN: N/A
INV OUT: N/A
12"CPP
6"CPP
8"PVC
"C
PP
(A
(B)
(C
"R
C P
"C
PP
"R
C P
(D
"R
C P
(B
6"DIP (C)
DROP INLET
RIM: 15.23'
INV IN (A): 8.73'
INV IN (B): 8.13'
INV IN (C): 10.18'
INV OUT (D): 7.93'
8"PVC
8"
PV
C
8"PVC
8"PVC
8"
PV
C
8"
VC
P
"C
PP
12"CPP
"C
PP
6"CPP
6" C
PP
6"
C
PP
SANITARY MANHOLE
RIM: 16.83'
LID SEALED
TRN #12
N:227697.33 E:2087202.88
ELEV.:17.723
6' WOOD FENCE
8"PVC
DUMPSTER
ENCLOSURE
TBM #4
N:227585.68 E:2087117.83
ELEV.:17.346
TRANSF.
TBM #3
N:27342.86 E:2087164.01
ELEV.:15.742
8"
TRANSF.
X
X X
X
DROP INLET
RIM: 16.22'
INV OUT: 13.62'
DROP INLET
RIM: 16.39'
INV IN (A): 13.54'
INV IN (B): 13.54'
INV OUT (C): 13.49'
DROP INLET
RIM: 16.15'
INV OUT: 14.64'
DROP INLET
RIM: 15.60'
INV IN (A): 13.56'
INV IN (B): 12.70'
INV OUT (C): 11.97'
TRN #14
N:227556.22 E:2087185.50
ELEV.:17.577
SANITARY MANHOLE
RIM: 16.91'
INV IN (A): 9.91'
INV IN (B): 11.71'
INV IN (C): 11.31'
INV IN (D): 10.16'
INV OUT (E): 9.81'
"R
C P
6" C
PP
(B
(A) (C)
DROP INLET
RIM: 16.41'
INV IN (A): 14.09'
INV IN (B): 13.48'
INV OUT (C): 13.59'
UNABLE TO FIND
END OF PIPE
BUILDING 1244F
BUILDING 1245G
BUILDING 1247I
BU
IL
D
IN
G
15.87
15.71
15.61
16.3416.86
16.75 16.25
16.99
16.9016.94
17.02
17.0117.02
16.90
16.9516.93
.9
.0
17.05 17.10
17.23
17.30
17.38
17.21
.8
17.06
.3
17.47
.5
.6
.6
17.64
17.58 17.63
17.6817.69
17.76
17.60 17.60
17.21 17.31
17.18
.1
16.72
16.75 16.62
16.60
.6
16.62
16.93
17.01
16.62
16.6317.3717.37
17.32 17.39
17.65 17.65
16.25
16.42 16.50
16.46 16.32
16.51
15.75
15.6016.2916.49
16.46 16.45
16.55
17.00 17.01
17.37
.4
16.49
15.95
16.9116.6116.55
17.31
17.59 17.5117.8217.63
17.60
17.1817.05
16.93
17.40
17.4417.19
17.21
18.28
16.56
15.95
16.42
16.30
.9
16.13
16.75 16.61 16.67
17.77
15.35
15.17
16.66
16.67
16.73
16.62 17.37
VF101B
EXISTING TOPOGRAPHIC SURVEY
N O
R
TH
SCALE: 1" = 20'
20' 0 20' 40'
GRAPHIC SCALE
EXISTING TOPOGRAPHIC SURVEY 1 SCALE: 1" = 20'-0"
I HEREBY STATE THAT TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,
INFORMATION, AND BELIEF, THE SURVEY SHOWN HEREON WAS MADE IN
ACCORDANCE WITH THE REQUIREMENTS OF THE STANDARDS OF PRACTICE
MANUAL FOR SURVEYING IN SOUTH CAROLINA, AND MEETS OR EXCEEDS THE
REQUIREMENTS FOR A CLASS A SURVEY AS SPECIFIED THEREIN; ALSO THERE
ARE NO VISIBLE ENCROACHMENTS OR PROJECTIONS OTHER THAN SHOWN.
DAVID E. LUKAC JR., PLS. #28600
SHEET
SIZE
F
SCALE: AS NOTED OF
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS AIR STATION
BEAUFORT, S.C.
T.O. #
CONSTR. CONTR. NO.:
MACC.
CODE IDENT. NO. N A V F A C DRAWING NO.
IF SHEET IS LESS THAN (34"x22") IT IS A
REDUCED PRINT; SCALE ACCORDINGLY
P.W. DWG. NO.
DRAWN BY
CHECKED BY
SUPERVISOR
APPROVED DATE
PUBLIC WORKS OFFICER
NATURAL RESOURCES & ENVIRONMENTAL AFFAIRS
SAFETY DEPARTMENT
FIRE DEPARTMENT
PHYSICAL SECURITY
PUBLIC WORKS SUPERVISOR
HQMC PROJ. NO.:
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
N40085-18-D-0616
REVISIONS
SYM. DESCRIPTION DATE APP.
www.cems-ae.com | Summerville, SC | Wilmington, NC | 843.875.3637
REPAIR PHASE 4 BEQ BUILDING 1245G
(BE1813M)
ISSUE DATE: 08 SEPT 2023
GENERAL NOTES:
1. ALL DISTANCES ARE HORIZONTAL GROUND IN
INTERNATIONAL FEET UNLESS OTHERWISE
SHOWN.
2. HORIZONTAL DATUM: NAD 1983/2011(SC)
VERTICAL DATUM: NAVD 1988
3. SURVEY COMPLETED BY McKIM & CREED IS
BASED ON PHYSICAL EVIDENCE FOUND IN
NOVEMBER 2022.
4. SURVEYOR HAS MADE NO INVESTIGATION OR
INDEPENDENT SEARCH FOR EASEMENTS OF
RECORD, ENCUMBRANCES, RESTRICTIVE
COVENANTS, OWNERSHIP, TITLE EVIDENCE,
OR ANY OTHER FACTS THAT AN ACCURATE
AND CURRENT TITLE SEARCH MAY DISCLOSE.
5. BROKEN LINES INDICATE PROPERTY LINES
NOT SURVEYED.
6. THE OFF-SITE RIGHT-OF-WAY/PROPERTY LINE
SHOWN HEREON IS FOR ILLUSTRATIVE
PURPOSES ONLY. THE UNDERSIGNED
CERTIFIES ONLY TO THE
RIGHT-OF-WAY/PROPERTY LINES SURVEYED,
AND DOES NOT CERTIFY TO THE
RIGHT-OF-WAY WIDTH/PROPERTY LINE OF ANY
ADJACENT PROPERTIES.
7. THE SUBJECT PROPERTY IS LOCATED WITHIN
2000' OF A HORIZONTAL NGS MONUMENT.
8. HORIZONTAL COORDINATES BASED UPON
SC-RTN GPS OBSERVATIONS USING TRIMBLE
"R12i" UNITS. THE NETWORK POSITIONAL
ACCURACY OF THE SC-RTN DERIVED
POSITIONAL COORDINATES MEETS OR
EXCEEDS THE CLASS A HORIZONTAL
POSITIONS. COORDINATES BASED UPON
GEOID 18 AND HAVE A 95% CONFIDENCE
RATING. VERTICAL DATUM HAS BEEN
ADJUSTED TO NAVD '88.
9. UNDERGROUND UTILITIES ARE SHOWN ONLY
WHERE ABOVEGROUND SERVICES WERE
VISIBLE.
10. SUBSURFACE AND ENVIRONMENTAL
CONDITIONS WERE NOT EXAMINED OR
CONSIDERED AS A PART OF THIS SURVEY. NO
STATEMENT IS MADE CONCERNING THE
EXISTENCE OF UNDERGROUND OR OVERHEAD
CONTAINERS OR FACILITIES THAT MAY
AFFECT THE USE OR DEVELOPMENT OF THIS
TRACT.
NOTE:
EXISTING TOPOGRAPHIC SURVEY SHOWS
EXISTING CONDITIONS OF EACH BEQ 1244 1245
1246 AND 1247 PRIOR TO ANY CONTRACT WORK.
FOLLOWING SHEETS SHOW BEQ 1244 AND 1247 AS
COMPLETED. CONTRACTOR SHALL ACQUIRE ALL
THREE SETS OF PLANS ASSOCIATED WITH BEQ
1244, 1245, 1246 AND 1247 TO COMPLETE ALL
REQUIRED WORK SHOWN.
28459
10/04/2023
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
PER RECORD
U E
D
AT
U R
U E
D
AT
U R
U E
D
AT
U R
UE DATURUE DATURUE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
U E D
ATU
R
U E D
ATU
R
UE DATUR
UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR
UE D
ATUR
UE D
ATUR
UE DATUR
UE DATUR
UE D
ATU
R
UE DATUR UE DATUR
PER RECORD
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST
D
AT
U R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR
ST
D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
4" C
PP
DROP INLET
RIM: 15.60'
INV IN (A): 13.56'
INV IN (B): 12.70'
INV OUT (C): 11.97'
DROP INLET
RIM: 16.12'
INV IN: 13.77'
INV OUT: 13.72
DROP INLET
RIM: 15.60'
INV OUT: 15.05'
DROP INLET
RIM: 16.39'
INV IN (A): 13.54'
INV IN (B): 13.54'
INV OUT (C): 13.49'
DROP INLET
RIM: 16.15'
INV OUT: 14.64'
12"CPP
"C
PP
(A
12"CPP
6" C
PP
6"
C
PP
DROP INLET
RIM: 15.08'
INV IN: 12.00'
INV OUT: 11.90'
DROP INLET
RIM: 16.74'
INV OUT: 15.31'
"R
C P
"R
C P
(D
"R
C P
(B
6"DIP (C)
DROP INLET
RIM: 15.23'
INV IN (A): 8.73'
INV IN (B): 8.13'
INV IN (C): 10.18'
INV OUT (D): 7.93'
"C
PP
DRAINAGE MANHOLE
RIM: 17.48'
INV OUT: NO PIPES
DROP INLET
RIM: 16.22'
INV OUT: 13.62'
DROP INLET
RIM: 15.34'
INV IN (A): 12.84'
INV IN (B): 13.04'
INV OUT (C): 12.74'
W D
ATU
R W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR
W D
ATU
R
W D
ATU
R
W D
ATU
RW DATURW DATUR
W D
AT
U
R W
D
AT
U R
TU DATUR TU DATUR TU DATUR TU DATUR TU DATUR TU DATUR
TU DATUR
TU DATUR
TU DATUR
W D
AT
U
R W
D
AT
U R
W DATURW DATUR
W DATUR W DATUR
TRN #11
N:227546.87 E:2087350.84
ELEV.:16.776
SCO
ST
AI
R S
ST
AI
R S
STAIRS
BR
EE
ZE
W
AY
PA
VI
LI
O
N
ST
AI
R S
STAIRS
BR
EE
ZE
W
AY
HORSESHOE PIT
TRANSF.
CONCRETE
BARRICADE (TYP.)
BIKE
RACK
GRILL
U N
KN
O
W N
VA
LV
E
SD DATUR
SD DATURSD DATURSD DATUR
8"
8"
8"
PARKING
BLOCK (TYP.)
PARKING
BLOCK (TYP.)
C O
VE
R
ED
W
AL
KW
AY
COVERED
WALKWAY
TRASH
CAN
TRASH
CAN
TRN #13
N:227714.46 E:2087329.40
ELEV.:17.420 SAND VOLLEYBALL
COURT
SANITARY MANHOLE
RIM: 16.55'
INV IN: 11.20'
INV OUT: 11.05'
SANITARY MANHOLE
RIM: 17.38'
INV IN: 12.74'
INV OUT: 12.67'
SANITARY MANHOLE
RIM: 16.73'
INV IN: 12.08'
INV OUT: 11.93'
SANITARY MANHOLE
RIM: 17.12'
INV OUT: 12.42'
SANITARY MANHOLE
RIM: 16.68'
INV IN: N/A
INV OUT: N/A
6"CPP
8"PVC
(B)
8"PVC
8"
PV
C
8"PVC
8"PVC
8"
PV
C
8"
VC
P
6"CPP
SANITARY MANHOLE
RIM: 16.83'
LID SEALED
TRN #12
N:227697.33 E:2087202.88
ELEV.:17.723
6' WOOD FENCE
TRN #14
N:227556.22 E:2087185.50
ELEV.:17.577
8"PVC
DUMPSTER
ENCLOSURE
TBM #4
N:227585.68 E:2087117.83
ELEV.:17.346
TRANSF.
TBM #3
N:27342.86 E:2087164.01
ELEV.:15.742
8"
TRANSF.
DC1
(C
"C
PP
SANITARY MANHOLE
RIM: 16.91'
INV IN (A): 9.91'
INV IN (B): 11.71'
INV IN (C): 11.31'
INV IN (D): 10.16'
INV OUT (E): 9.81'
DC9
DC10
DC12 TYP.
DC10
DC11 TYP.
DC11TYP.
DC12TYP.
DC8
DC6
DC4
DC4
DC5
DC7
DC1
TYP.
TYP.
DC1
DC3
DC3
TYP.
DC11TYP.
DROP INLET
RIM: 16.46'
INV IN: 14.21'
INV OUT: 14.11'
SD DATUR
DC13 DC13 DC13
DC13
DC3
DC2
SEE NOTE 4
6" C
PP
(B
(C)
DROP INLET
RIM: 15.89'
INV IN: 13.39'
INV OUT: 13.34'
END OF PIPE
DC1
TYP.
DC1 TYP.
DC1
TYP.
DC1
DC8
TYP. TYP.
TYP.
DROP INLET
RIM: 16.41'
INV IN (B): 13.48'
INV OUT (C): 13.59'
DC8
DC14
DC9
BUILDING 1244F
BUILDING 1245G
BUILDING 1247I
BU
IL
D
IN
G
.8
.7
.6
16.3416.86
16.75 16.25
16.99
16.9016.94
17.02
17.01 17.02
16.90
16.95 16.93
16.99
17.01
17.05 17.10
17.23
17.30
17.37 17.38
17.21
16.80
17.06
17.37
17.47
.5
17.68
17.65 17.64
17.58 17.63
17.6817.69
17.76
17.60
17.60
17.21 17.31
17.18
.1
16.72 16.75
16.62
.6
16.63 16.62
16.93
17.01
16.62
16.6317.3717.37
17.32 17.39
17.65 17.65
16.25 16.42
16.50
16.46 16.32
16.51
15.75
15.6016.29 16.49
16.46
16.45
16.55
17.00 17.01
17.37
.4
16.49
15.95
16.9116.6116.55
17.31
17.59
17.51
17.82
17.63
17.60
17.18 17.05
16.93
17.40
17.44 17.19
17.21
18.28
16.56
15.95
16.42
16.30
.9
916.13
16.75 16.61
17.77
15.35
15.17
16.66
16.67
16.73
16.62
TYP.
TYP.
16.67
OCCUPIED
UNOCCUPIED
OCCUPIED
J. BARNES
CD101B
D. FARLEY
DEMOLITION / EROSION CONTROL PLAN
N O
R
TH
SCALE: 1" = 20'
20' 0 20' 40'
GRAPHIC SCALE
C. MOORING
DEMOLITION / EROSION CONTROL PLAN1 SCALE: 1" = 20'-0"
SHEET
SIZE
F
SCALE: AS NOTED OF
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS AIR STATION
BEAUFORT, S.C.
T.O. #
CONSTR. CONTR. NO.:
MACC.
CODE IDENT. NO. N A V F A C DRAWING NO.
IF SHEET IS LESS THAN (34"x22") IT IS A
REDUCED PRINT; SCALE ACCORDINGLY
P.W. DWG. NO.
DRAWN BY
CHECKED BY
SUPERVISOR
APPROVED DATE
PUBLIC WORKS OFFICER
NATURAL RESOURCES & ENVIRONMENTAL AFFAIRS
SAFETY DEPARTMENT
FIRE DEPARTMENT
PHYSICAL SECURITY
PUBLIC WORKS SUPERVISOR
HQMC PROJ. NO.:
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
N40085-18-D-0616
REVISIONS
SYM. DESCRIPTION DATE APP.
www.cems-ae.com | Summerville, SC | Wilmington, NC | 843.875.3637
REPAIR PHASE 4 BEQ BUILDING 1245G
(BE1813M)
ISSUE DATE: 08 SEPT 2023
GENERAL NOTES:
1. SEE SHEET C-001B FOR PROJECT NOTES AND
LEGEND.
2. BUILDING(S) HAVE MULTIPLE ALUMINUM
DOWNSPOUTS THAT CONNECT TO EXISTING
UNDERGROUND STORM SYSTEM. ALL DOWNSPOUTS
WILL BE REMOVED AND REPLACED AS PART OF THIS
RENOVATION WORK (SOW). SEE ARCHITECTURAL
FOR MORE INFORMATION.
3. CONTRACTOR SHALL VERIFY ALL EXTERIOR SITE
FEATURES AND UTILITIES PRIOR TO DEMOLITION
WORK.
4. CONTRACTOR TO BE AWARE THESE LOCATIONS ARE
UNDER A COVERED WALKWAY AND PROPOSED
WORK MAY REQUIRE SMALLER EQUIPMENT AND
WORK WITH HAND TOOLS.
5. CONTRACTOR TO BE AWARE THIS AREA CONTAINS
SEVERAL CONCRETE PROTECTIVE BARRIER(S).
BARRIER(S) NOT INDICATED TO BE TEMPORARILY
MOVED FOR CONSTRUCTION EFFORTS MUST BE
COORDINATED WITH MCAS BEAUFORT PHYSICAL
SECURITY (MR. MILLER) PRIOR TO MOVING.
BARRIER(S) TO BE REPLACED IN PREVIOUS
LOCATION AFTER INSTALLATION OF NEW WORK.
6. CONTRACTOR IS REQUIRED TO PROVIDE AND
MAINTAIN TEMPORARY CHAIN LINK FENCING FOR
THE DURATION OF CONSTRUCTION. FENCING SHALL
NOT BE PERMANENTLY MOUNTED IN THE GROUND.
THE FENCING AND POSTS SHALL BE A PORTABLE
SELF STANDING SYSTEM. SEE DETAIL 6/C-501A.
7. BUILDING 1245G SHALL BE UN-OCCUPIED FOR
REPAIRS / CONSTRUCTION UNDER THIS CONTRACT.
8. BUILDING 1247I "DUTY HUT" MUST BE ACCESSIBLE
FOR BASE PERSONNEL AT ALL TIMES FOR LAUNDRY
USAGE DURING CONSTRUCTION.
9. BUILDING 1244F, 1246H, AND 1247I SHALL BE
OCCUPIED DURING REPAIRS / CONSTRUCTION
UNDER THIS CONTRACT. ACCESS TO THESE
BUILDINGS SHALL NOT BE IMPEDED AT ANY TIME
DURING CONSTRUCTION.
SHEET KEYNOTES
DC1 REMOVE STORM DRAIN LINE
DC2 REMOVE ENTIRE STORM DRAIN INLET
STRUCTURE
DC3 REMOVE CONCRETE SIDEWALK
DC4 SAWCUT AND REMOVE ASPHALT PAVEMENT
DC5 REMOVE CONCRETE PAVEMENT
DC6 REMOVE PAVEMENT MARKINGS
DC7 REMOVE CONCRETE WHEELSTOP
DC8 REMOVE TREE
DC9 INLET PROTECTION
(SEE DETAIL 4/C-501B)
DC10 TREE PROTECTION
(SEE DETAIL 5/C-501B)
DC11 LIMITS OF DISTURBANCE
DC12 LIMITS OF CONSTRUCTION AND MIN. LIMITS
OF TEMPORARY CONSTRUCTION CHAIN LINK
FENCING. SEE NOTE 6.
(SEE DETAIL 6/C-501)
DC13 SILT FENCE
(SEE DETAIL 1/C-501B)
DC14 CONTRACTOR SHALL TEMPORARILY MOVE
CONCRETE PROTECTIVE BARRIER(S), AS
NECESSARY. MOVE SHALL BE COORDINATED
WITH MCAS BEAUFORT PHYSICAL SECURITY
MR. MILLER). BARRIER(S) TO BE PLACED IN
PREVIOUS LOCATION AFTER INSTALLATION
OF NEW WORK
28460
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
U E D
ATU
R
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
PER RECORD
U E
D
AT
U R
U E
D
AT
U R
U E
D
AT
U R
UE DATURUE DATURUE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
UE DATUR
U E D
ATU
R
U E D
ATU
R
UE DATUR
UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR UE DATUR
UE D
ATUR
UE D
ATUR
UE DATUR
UE DATUR
UE D
ATU
R
UE DATUR UE DATUR
PER RECORD
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST
D
AT
U R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR
ST
D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST D
AT
U
R
ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST DATUR ST DATUR ST DATUR
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
ST D
ATU
R
4" C
PP
DROP INLET
RIM: 15.60'
INV IN (A): 13.56'
INV IN (B): 12.70'
INV OUT (C): 11.97'
DROP INLET
RIM: 16.12'
INV IN: 13.77'
INV OUT: 13.72
DROP INLET
RIM: 15.60'
INV OUT: 15.05'
DROP INLET
RIM: 16.15'
INV OUT: 14.64'
12"CPP
"C
PP
(A
12"CPP
6" C
PP
6"
C
PP
DROP INLET
RIM: 15.08'
INV IN: 12.00'
INV OUT: 11.90'
DROP INLET
RIM: 16.74'
INV OUT: 15.31'
"R
C P
"R
C P
(D
"R
C P
(B
6"DIP (C)
DROP INLET
RIM: 15.23'
INV IN (A): 8.73'
INV IN (B): 8.13'
INV IN (C): 10.18'
INV OUT (D): 7.93'
"C
PP
DRAINAGE MANHOLE
RIM: 17.48'
INV OUT: NO PIPES
DROP INLET
RIM: 16.22'
INV OUT: 13.62'
W D
ATU
R W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR W DATUR
W D
ATU
R
W D
ATU
R
W D
ATU
RW DATURW DATUR
W D
AT
U
R W
D
AT
U R
TU DATUR TU DATUR TU DATUR TU DATUR TU DATUR TU DATUR
TU DATUR
TU DATUR
TU DATUR
W D
AT
U
R W
D
AT
U R
W DATURW DATUR
W DATUR W DATUR
TRN #11
N:227546.87 E:2087350.84
ELEV.:16.776
SCO
ST
AI
R S
ST
AI
R S
STAIRS
BR
EE
ZE
W
AY
PA
VI
LI
O
N
ST
AI
R S
STAIRS
BR
EE
ZE
W
AY
HORSESHOE PIT
TRANSF.
CONCRETE
BARRICADE (TYP.)
BIKE
RACK
GRILL
U N
KN
O
W N
VA
LV
E
SD DATUR
SD DATURSD DATURSD DATUR
8"
8"
8"
PARKING
BLOCK (TYP.)
PARKING
BLOCK (TYP.)
C O
VE
R
ED
W
AL
KW
AY
COVERED
WALKWAY
TRASH
CAN
TRASH
CAN
TRN #13
N:227714.46 E:2087329.40
ELEV.:17.420 SAND VOLLEYBALL
COURT
SANITARY MANHOLE
RIM: 16.55'
INV IN: 11.20'
INV OUT: 11.05'
SANITARY MANHOLE
RIM: 17.38'
INV IN: 12.74'
INV OUT: 12.67'
SANITARY MANHOLE
RIM: 16.73'
INV IN: 12.08'
INV OUT: 11.93'
SANITARY MANHOLE
RIM: 17.12'
INV OUT: 12.42'
SANITARY MANHOLE
RIM: 16.68'
INV IN: N/A
INV OUT: N/A
8"PVC8"PVC
8"
PV
C
8"PVC
8"PVC
8"
PV
C
8"
VC
P
SANITARY MANHOLE
RIM: 16.83'
LID SEALED
TRN #12
N:227697.33 E:2087202.88
ELEV.:17.723
6' WOOD FENCE
TRN #14
N:227556.22 E:2087185.50
ELEV.:17.577
8"PVC
DUMPSTER
ENCLOSURE
TBM #4
N:227585.68 E:2087117.83
ELEV.:17.346
TRANSF.
TBM #3
N:27342.86 E:2087164.01
ELEV.:15.742
8"
TRANSF.
SANITARY MANHOLE
RIM: 16.91'
INV IN (A): 9.91'
INV IN (B): 11.71'
INV IN (C): 11.31'
INV IN (D): 10.16'
INV OUT (E): 9.81'
C4 TYP.
C5 TYP.
C5 TYP.
C4TYP.
C8
C9C5
TYP.
C7
C4 TYP.
C5 TYP.
C4
C4 TYP.
C5
TYP.
C2
C2 C3
C11
C10
C1
C1
C13
TYP.
C12
DROP INLET
RIM: 16.46'
INV IN: 14.21'
INV OUT: 14.11'
SD DATUR
C2
C6
SEE NOTE 4
SEE NOTE 4
6" C
PP
(B
(C)
DROP INLET
RIM: 15.89'
INV IN: 13.39'
INV OUT: 13.34'
END OF PIPE
DROP INLET
RIM: 16.41'
INV IN (B): 13.48'
INV OUT (C): 13.59'
DROP INLET
RIM: 15.34'
INV IN (A): 12.84'
16.4'
16.3' 15.4'
16' 16.2'
16.6'
16.3'
BUILDING 1244F
BUILDING 1245G
BUILDING 1247I
BU
IL
D
IN
G
.8
.7
.6
16.3416.86
16.75 16.25
16.99
16.9016.94
17.02
17.01 17.02
16.90
16.95 16.93
16.99
17.01
17.05 17.10
17.23
17.30
17.37 17.38
17.21
16.80
17.06
17.37
17.47
.5
17.68
17.65 17.64
17.58 17.63
17.6817.69
17.76
17.60
17.60
17.21 17.31
17.18
.1
16.72 16.75
16.62
.6
16.63 16.62
16.93
17.01
16.62
16.6317.3717.37
17.32 17.39
17.65 17.65
16.25 16.42
16.50
16.46 16.32
16.51
15.75
15.6016.29 16.49
16.46
16.45
16.55
17.00 17.01
17.37
.4
16.49
15.95
16.9116.6116.55
17.31
17.59
17.51
17.82
17.63
17.60
17.18 17.05
16.93
17.40
17.44 17.19
17.21
18.28
16.56
15.95
16.42
16.30
.9
916.13
16.75 16.61
17.77
15.35
15.17
16.66
16.67
16.73
16.62
16.67
OCCUPIED
UNOCCUPIED
OCCUPIED
J. BARNES
CS101B
D. FARLEY
SITE PLAN
N O
R
TH
SCALE: 1" = 20'
20' 0 20' 40'
GRAPHIC SCALE
C. MOORING
SITE PLAN1 SCALE: 1" = 20'-0"
SHEET
SIZE
F
SCALE: AS NOTED OF
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS AIR STATION
BEAUFORT, S.C.
T.O. #
CONSTR. CONTR. NO.:
MACC.
CODE IDENT. NO. N A V F A C DRAWING NO.
IF SHEET IS LESS THAN (34"x22") IT IS A
REDUCED PRINT; SCALE ACCORDINGLY
P.W. DWG. NO.
DRAWN BY
CHECKED BY
SUPERVISOR
APPROVED DATE
PUBLIC WORKS OFFICER
NATURAL RESOURCES & ENVIRONMENTAL AFFAIRS
SAFETY DEPARTMENT
FIRE DEPARTMENT
PHYSICAL SECURITY
PUBLIC WORKS SUPERVISOR
HQMC PROJ. NO.:
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
SATISFACTORY TO DATE
N40085-18-D-0616
REVISIONS
SYM. DESCRIPTION DATE APP.
www.cems-ae.com | Summerville, SC | Wilmington, NC | 843.875.3637
REPAIR PHASE 4 BEQ BUILDING 1245G
(BE1813M)
ISSUE DATE: 08 SEPT 2023
1. SEE SHEET C-001B FOR PROJECT NOTES AND
LEGEND.
2. CONCRETE SIDEWALKS AND/OR PAVEMENTS
DAMAGED DUE TO CONSTRUCTION, BUT NOT
DIRECTLY IDENTIFIED ON PLANS, SHALL BE
REMOVED & RESTORED TO ORIGINAL CONDITIONS
AT NO ADDITIONAL COST TO PROJECT
(CONTRACTOR EXPENSE).
3. A MINIMUM 18" SEPARATION SHALL BE
MAINTAINED WHEN WATER LINE AND SEWER LINE
CROSS IN A PERPENDICULAR ALIGNMENT. A
MINIMUM 10' HORIZONTAL SEPARATION SHALL BE
MAINTAINED WHEN WATER LINE AND SEWER LINE
ROUTE IN A PARALLEL ALIGNMENT. IF REQUIRED
CLEARANCES CANNOT BE MAINTAINED, FERROUS
PIPE MATERIAL (DUCTILE IRON OR STEEL
ENCASEMENT) SHALL BE REQUIRED.
4. CONTRACTOR TO CORE EXISTING INLETS FOR
NEW CONNECTIONS AND SHALL BE WATERTIGHT
SEALS WITH BOOTS OR GROUT FILL.
5. SEE SHEET C-502B FOR STORM DRAIN INLET…
This is the start of the file's text. The full file is on GovTribe.