Amendment 0005 - Attachment C NSWC PNYA Roofs (Revised).xlsx
XLSX spreadsheet 14 KB Posted
- Solicitation number
- N4008526B0006
About this file
This file is an attachment listing roof inventory and specifications for buildings located at Naval Support Weapons Center Philadelphia Naval Yard Area (NSWC PNYA). The spreadsheet catalogs approximately 30 buildings with detailed roof information including roof type, approximate square footage, pitch, parapet details, construction dates, manufacturer warranties, and roof access methods. Roof types vary widely and include corrugated aluminum, asphalt built-up systems, standing seam painted aluminum, modified bitumen, TPO (thermoplastic polyolefin), and EPDM membranes. Square footage ranges from approximately 484 SF to 106,150 SF per roof section, with construction dates spanning from approximately 1980 to 2012. Warranty information indicates coverage periods ranging from 5 to 20 years from various manufacturers including MuleHide, Tremco, GAF, Johns Manville, and others.
The inventory identifies roof access methods as either exterior ladders, high-reach access, internal stairs/elevators, or penthouse access, which will be relevant for determining maintenance and replacement approach requirements under the associated IDIQ roofing maintenance and replacement contract. This comprehensive facility data serves as baseline documentation for the roofing services contract covering Department of Navy installations at Philadelphia Naval Business Center, Naval Support Activity Philadelphia, and Naval Support Activity Mechanicsburg, enabling contractors to understand the scope and diversity of roofing systems that may require repair, replacement, or maintenance work during the contract period.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Roofs
ATTACHMENT C
NSWC Buildings Located at PNYA
| Building | Roof-type | Approx. SF | Pitch | Parapet | Date of Roof Construction | Warranty - Manufacturer | Roof Access (See Note 2) | Notes |
| 29 (Roof A) | Corrugated Alum. | 18,602 | 7/12 | Approx. 1980 | Coating - MuleHide (Kalimex 2007) | High reach / ladder | ||
| 29 (Roof B-E) | Asphalt Built-up | 8,686 | Flat | Yes | 2006 - MidAtlantic | Ext. stairway | ||
| 29 (Roof F-H) | Asphalt Built-up | 1,726 | Flat | Yes | 2006 - MidAtlantic | Ext. stairway | ||
| 4 (Roofs A-I, K) | Standing seam painted alum. | 33,816 | 2/12 - 5/12 | Approx. 1985 | High reach / ladder | |||
| 4 (J & L) | Standing seam painted alum. | 14,562 | 5/12 | 2009 | American Alliance/Merchant & Evans | High reach / ladder | ||
| 4 (Roofs M,O,Q) | Mod. bit., 3-ply Built-up, w/ cap | 1,600 | Flat | No | 2004 - Eagle Roofing | Tremco 20-year warranty (2004) | Int. Stairs / elevator | |
| 4 (Roofs N,R,P) | 4 ply modified with cap | 14,000 | Flat | No | 2007 - R.L. Campbell | Tremco 5-year TPW (2004) | Int. Stairs / elevator | |
| 633 (Roof A & B) | Modified Bitumen | 12,900 | Flat | Yes | 2011 Brown and Guarino | GAF 20 Year (2031) | Penthouse/Ext Ladder | |
| 633 (Roof C) | Asphalt Built-up w/insul. | 35,784 | Flat | Yes | 1997 | Tremco 5-year warranty (2001) | Int. Stairs / Ladder | |
| 633 (Roof D1 & D2) | Smooth-surface Asphalt Built-up | 13,040 | Flat | Partial | 1997 | Tremco 5-year warranty (2001) | Int. Stairs / Ladder | |
| 633 (Roof E) | Smooth-surface Asphalt Built-up | 17,990 | Flat | Yes | Approx. 1985 | Int. Stairs / Ladder | ||
| 633 (Roof F) | 4-ply Asphalt BUR w/ syn cap sheet | 34,536 | Flat | Yes | 2007 | Kalimex | Int. Stairs / Ladder | |
| 670 | TPO 60 mil | 8,400 | Flat | Partial | 2011 Johnson/Pro Com | Johnson Roofing | Ext Ladder | |
| 745 (Roofs A-C) | 4-ply Asphalt Built-up - smooth | 4,177 | Approx. 2000 | Ext. ladder | ||||
| 756 (Roofs A-C) | 4-ply Asphalt BUR & corrugated | 11,231 | 2007 - Benaka | Ext. Ladder | ||||
| 77H (Roofs A&E) | Mod. bit., 3-ply Built-up, w/ cap | 70,000 | Flat | Partial | 2004 - Eagle Roofing | Tremco 20-year warranty (2004) | Int. / Ext. Ladders | |
| 77H (Roofs B,C,D) | Standing seam painted alum. | 72,930 | 7/12 | No | 2009 | Kalimex/Merchant & Evans | Int. / Ext. Ladders | |
| 77H (Roof F) | 0.060 EPDM - fully adhered | 2,880 | Flat | No | 1987 | Int. / Ext. Ladders | ||
| 77H East Locker Room | TPO 60 mil | 2,000 | Flat | Partial | 2011 Johnson/Pro Com | Johnson Roofing | Ladder/High Reach | |
| 77L (High roofs) | EPDM - 0.090 mil (over SPUF) | 94,000 | Flat | Yes | 2005 MidAtlantic | 2001 Company Inc. 20-year | Ext. Ladder | |
| 77L (Low roofs) | Mod. bit., 3-ply Built-up, w/ cap | 48,000 | Flat | No | 2003 Boro Const. | Johns Manville 20-year | Ext. Ladder | Interior Roofs are bounded by walls |
| 87 (Roofs A-I) | Standing seam painted alum. Mod Bit Valleys | 106,150 | Yes | 2007 Benaka | Ext. Ladder | |||
| 87 (Roof J) | 0.060 EDPM - fully adhered | 6,900 | Flat | Approx. 2001 | Ext. Ladder | |||
| 666 | Asphalt Built-up w/insul. | 2,000 | Flat | Yes | ||||
| 770 | Flat | Yes | ||||||
| 771 | TPO 60 mil | 3,400 | Flat | No | 2011 Johnson/Pro Com | Johnson Roofing | Ext. ladder | |
| 776 | 0.060 EPDM | 2,268 | Flat | Approx. 1998 | Ext. ladder | |||
| 779 | ||||||||
| 1000 (Roof H&J) | Smooth-surface Asphalt Built-up | 484 | Flat | No | 2012 Persaud/Belcher | Johns-Manville | Int. Stairs / elevator | |
| 1000 (Roof I) | 4-ply Asphalt Built-up w/insul. | 3,800 | Flat | No | 2012 Persaud/Belcher | Johns-Manville | Int. Stairs / elevator | |
| 1000 (Roofs A-G) | 4-ply Asphalt Built-up w/insul. | 100,126 | Flat | No | 2012 Persaud/Belcher | Johns-Manville | Int. Stairs / elevator | |
| 519/520 (Roofs A) | 0.060 EPDM | 17,635 | Flat | No | Approx. 2002 | Ext. ladder | ||
| 519/520( B-H; L-O) | Asphalt Built-up w/insul. | UNK | Flat | No | Approx. 2002 | Ext. ladder | ||
| 542 (Roofs A-C) | 4-ply Asphalt Built-up w/insul. | 107,730 | Flat | No | Approx. 2000 | Tremco 20-year warranty (2004) | Ext. ladder |
Attachment 1 PNBC Gutter and Drain Cleaning
Page &P of &N