About this file

This is a Roof Survey/Assessment Scope of Work attachment that outlines the specific deliverables and methodology required for evaluating roof conditions at government facilities. The contractor must conduct tenant and facility personnel interviews to document roof history and existing problems, perform comprehensive visual surveys of all roof system components, and identify defective areas and potential moisture infiltration sources. The detailed written report must include roof age, type, and deck specifications; general and specific condition assessments; flashing and penetration evaluations; hazardous material test results; moisture and thermal imaging data; core samples where applicable; drain and gutter conditions; wall-to-roof interface conditions; repair recommendations; remaining roof life estimates; and sketches and photographs. The assessment must conclude with detailed cost estimates for all identified repairs needed.

This scope of work is associated with an Indefinite Delivery/Indefinite Quantity (IDIQ) maintenance construction contract administered by the Department of the Navy Naval Facilities Engineering Command for roofing services at three Department of Navy sites in Pennsylvania: Philadelphia Naval Business Center (4921 South Broad St), Naval Support Activity Philadelphia (700 Robbins St), and Naval Support Activity Mechanicsburg (5450 Carlisle Pike). The contract covers roof repair, replacement, and associated maintenance work at these installations.

View the file

Other files

File Type Posted
N4008526B0006 Bid Abstract.pdf PDF
Amendment 0010.pdf PDF
Amendment 0010 - Attachment ELINs Roofing IDIQ Revised.xlsx XLSX spreadsheet
Amendment 0009.pdf PDF
Amendment 0008 Pre-Proposal Inquiries.pdf PDF
Amendment 0008 - Attachment ELINs Roofing IDIQ Revised.xlsx XLSX spreadsheet
AMENDMENT 0008.pdf PDF
Amendment 0007 - Attachment E NWSS B1 NSAP.pdf PDF
Amendment 0007 - Attachment ELINs Roofing IDIQ Revised.xlsx XLSX spreadsheet
AMENDMENT 0007.pdf PDF
Amendment 0007 Pre-Proposal Inquiries.pdf PDF
Amendment 0007 UFGS 07 54 23 TPA.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005 - Attachment C NSWC PNYA Roofs (Revised).xlsx XLSX spreadsheet
Amendment 0005 - Attachment A General Specification.docx DOCX document
Amendment 0005 - Attachment D PNYA CNIC Bldg. 44 Roof (Revised).xlsx XLSX spreadsheet
AMENDMENT 0005.pdf PDF
Amendment 0005 - Attachment P NSA-M Base Map.pdf PDF
N4008526B0006 0005 PPI Responses.pdf PDF
Amendment 0005 - Attachment ELINs Roofing IDIQ Revised.xlsx XLSX spreadsheet
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
AMENDMENT 0001.pdf PDF
Amendment 0001 - Sign In Sheet Philadelphia.pdf PDF
Amendment 0001 - Sign In Sheet Mechanicsburg.pdf PDF
Attachment G NSA-P Site Map.pdf PDF
Attachment L Table 07 62 13 Copper Sheet Metal.pdf PDF
Attachment D PNYA CNIC Roofs.xlsx XLSX spreadsheet
Attachment O - SECNAV 5512.pdf PDF
Attachment N - PIEE Vendor Access Instructions.pdf PDF
Attachment F Lessons Learn Roof Fire.pptx PPTX presentation
Attachment J Table 07 60 00 Flashing Sheet Metal.pdf PDF
Attachment H PNYA Site Map.pdf PDF
Attachment A - IDIQ Specifications.pdf PDF
Attachment E Roof Survey Check List.pdf PDF
N4008526B0006.pdf PDF
Attachment I NSWC Roof Drawings.pdf PDF
Attachment B - Roofing IDIQ ELINs.xlsx XLSX spreadsheet
Attachment M - Pre-Proposal Inquiry (PPI) Form.xlsx XLSX spreadsheet
Attachment C NSWC PNYA Roofs.xlsx XLSX spreadsheet
Attachment K Table 07 61 14.00 20 Standing Seam Roof.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment B: Roof Survey / Assessment Scope of Work

1. Conduct an interview with the tenants and /or facility personnel familiar with the roof to get the history of the roof and roof problems.

2. Perform a visual survey of the roof systems to assess the conditions of the system components.

3. Locate defective areas and identify possible sources of moisture infiltration.

4. Conduct a thorough roof walk-through and provide a detailed written report with a minimum of the following items identified:

a) Roof age

b) Roof type

c) Roof deck type

d) General conditions

e) Roof condition

f) Base and curb flashing

g) Roof penetrations

h) Hazardous material test results

i) Moisture conditions

j) Thermal image conditions (if applicable)

k) Core samples (if applicable)

l) Roof drains, gutters and leaders

m) Wall to roof condition

n) Recommended repairs

o) Remaining roof life

p) Sketches and photographs

q) Detailed cost estimate of repairs needed

File details come from the government source that posted it. Updated .