Attachment M - JFCN IMF DB RFP - Amended.pdf
PDF 14 MB Posted
- Solicitation number
- N4008525R2638
About this file
This document is a Space Requirements and Programming Plan for the NATO Joint Force Command Norfolk (JFCN) Interim Modular Facility at Naval Support Activity Hampton Roads, Norfolk, Virginia, identifying detailed space allocations across multiple organizational departments. The facility encompasses 486 total personnel seats in the base bid configuration and 634 seats with the bid option, requiring a total net assignable area of 4,944 square meters (53,476 square feet) for base bid and 6,051 square meters (65,382 square feet) with bid option. The facility supports multiple joint operational divisions including the Joint Operations Center (JOC) with 40 personnel, Deputy Chief of Staff (DCOS) with 4 personnel, Intelligence Section (J2) with 92 personnel, Operations Section (J3) with 118 personnel, Logistics and Transportation (J4) with 55 personnel, Cyber/Information Systems (J6) with 33 personnel, Joint Force Development (J7) with 29 personnel, Plans and Policy (J5/J9) with 51 personnel, NATO Communications & Information Agency (NCIA) with 37 personnel, and National Support Element (NSE) with 26 personnel, along with shared support spaces and building infrastructure.
The programming plan specifies detailed room-by-room allocations with measurements in net square meters (NSM) and net square feet (NSF), including private offices, open office areas, conference and breakout rooms, administrative storage, and support facilities. Building support areas encompass 328 square meters (3,503 square feet) for base bid and 392 square meters (4,192 square feet) with bid option, including shared restrooms, telecommunications rooms, electrical infrastructure, mechanical and plumbing systems, and a classified communications facility. The gross area estimate for the base bid totals 7,115 square meters (76,841 square feet), while the bid option configuration totals 8,626 square meters (93,193 square feet), incorporating primary circulation (24 percent), building envelope (8 percent), permanent modular construction factors (5 percent), and building overhangs/canopies. Supporting documentation includes site demolition, site utility, and landscaping plans, with the facility designed as a permanent modular construction to accommodate NATO operational requirements for command and control operations at Naval Station Norfolk.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NATO JFCNF Interim Modular Facility Naval Support Activity
Hampton Roads, Norfolk, Virginia Work Order Number 1810892
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
Joint Operations Center (JOC) Shared Office Private 2 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Battle Watch C (BWC) Shift Director Private 1 1 7.5 SM 7.5 SM 81 SF 81 SF 12% 8.0 SM 90 SF
Deputy Chief of Operations (DCOS) Private 1 3 7.5 SM 22.5 SM 81 SF 242 SF 12% 25.0 SM 271 SF One office each for Operations, Plans and INTEL
Watch Floor (Workstations) Open 34 34 3.3 SM 112.2 SM 36 SF 1,208 SF 60% 180.0 SM 1,932 SF
Training Room Private 2 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF 2 NS and 2 NU
JOC Vestibule Enclosed - 1 5.6 SM 5.6 SM 60 SF 60 SF 0% 6.0 SM 60 SF
Subtotal 177.8 SM 1,914 SF 253.0 SM 2,715 SF
JOC Support Spaces
Breakout Room (Small) Enclosed - 3 6.7 SM 20.0 SM 72 SF 215 SF 12% 22.0 SM 241 SF
Breakout Room (Large) Enclosed - 1 80.0 SM 80.0 SM 861 SF 861 SF 12% 90.0 SM 964 SF
Printer Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Briefing Room Enclosed - 1 40.0 SM 40.0 SM 431 SF 431 SF 12% 45.0 SM 482 SF
Document Storage Enclosed - 1 10.0 SM 10.0 SM 108 SF 108 SF 12% 11.0 SM 121 SF
Storage Enclosed - 1 10.0 SM 10.0 SM 108 SF 108 SF 12% 11.0 SM 121 SF
Storage for bunks/cots, emergency supplies, tables, and chairs
Mechanical Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Flex Spaces Enclosed - 3 13.3 SM 40.0 SM 143 SF 430 SF 12% 45.0 SM 482 SF Bunk room, conference room
Subtotal 230.0 SM 2,476 SF 258.0 SM 2,773 SF
JOC Support Spaces - Adj to JOC/COC
Coordination Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Shower Rooms Enclosed - 2 15.0 SM 30.0 SM 161 SF 323 SF 12% 34.0 SM 362 SF Men's and Women's
Locker Rooms Enclosed - 2 17.5 SM 35.0 SM 188 SF 377 SF 12% 39.0 SM 422 SF Men's and Women's
Janitor Storage Enclosed - 1 6.0 SM 6.0 SM 65 SF 65 SF 12% 7.0 SM 72 SF
Break Room Open - 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF
11.25m2 is the minimum, space allocation 1.2 sm per pn
Subtotal 97.3 SM 1,047 SF 110.0 SM 1,173 SF
JOC Total 40 505.0 SM 5,436 SF 621.0 SM 6,661 SF
Deputy Chief of Staff (DCOS) DCOS Private Office Private 1 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF Each office to have table and chairs (TS & SIPR)
Shared Office Open 3 3 3.3 SM 9.9 SM 36 SF 107 SF 60% 16.0 SM 171 SF Workstations
Subtotal 24.9 SM 268 SF 33.0 SM 352 SF
DCOS Support Spaces
Collaboration Area Open - 1 6.0 SM 6.0 SM 65 SF 65 SF 28% 8.0 SM 83 SF For short briefing and discussion
Admin Storage Enclosed - 1 7.5 SM 7.5 SM 81 SF 81 SF 12% 8.0 SM 90 SF
Subtotal 13.5 SM 145 SF 16.0 SM 173 SF
DCOS Shared Spaces
Conference Room (Small) In shared spaces
Print Room In shared spaces
Break Room In shared spaces
DCOS Total 4 38.4 SM 413 SF 49.0 SM 525 SF
5/12/2026 1 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
J2 - INTEL
Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS
Open Office (Joint Intel Collection Branch) Open 20 20 3.3 SM 66.0 SM 36 SF 710 SF 60% 106.0 SM 1,137 SF Combined Open Office
Open Office (Joint Intel Direction Support Branch) Open 25 25 3.3 SM 82.5 SM 36 SF 888 SF 60% 132.0 SM 1,421 SF Combined Open Office
Open Office (Joint Intelligence J2/J3) Open 19 19 3.3 SM 62.7 SM 36 SF 675 SF 12% 70.0 SM 756 SF Combined Open Office
Open Office (Joint Intelligence Processing and Assessment) Open 21 21 3.3 SM 69.3 SM 36 SF 746 SF 60% 111.0 SM 1,194 SF Combined Open Office
Intel Vault Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF
EMB Shared 3 1 3.3 SM 3.3 SM 36 SF 36 SF 60% 5.0 SM 57 SF Connected to the Intel Vault
Subtotal 298.4 SM 3,368 SF 443.0 SM 4,951 SF
J2 Administrative Support Spaces
Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Administrative Storage Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 27.0 SM 291 SF 32.0 SM 346 SF
J2 Shared Spaces
Conference Room (Large) In shared spaces
Conference Room (Small) In shared spaces
Print Room In shared spaces
Documents Control and Mail Distribution In shared spaces
Break Room In shared spaces
J2 Total 92 325.4 SM 3,659 SF 475.0 SM 5,297 SF
J3 - Operations Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS
Open Office (J3/3 Current Operations Branch) Open 47 47 3.3 SM 155.1 SM 36 SF 1,669 SF 60% 248.0 SM 2,671 SF Combined Open Office
Open Office (J3/3 Coordination and Synchronization Branch) Open 20 20 3.3 SM 66.0 SM 36 SF 710 SF 60% 106.0 SM 1,137 SF Combined Open Office
Open Office (Joint Effects Branch) Open 15 15 3.3 SM 49.5 SM 36 SF 533 SF 60% 79.0 SM 853 SF Combined Open Office
Open Office (Force Protection Branch) Open 16 16 3.3 SM 52.8 SM 36 SF 568 SF 60% 84.0 SM 909 SF Combined Open Office
Open Office (Joint Assessment Branch) Open 17 17 3.3 SM 56.1 SM 36 SF 604 SF 60% 90.0 SM 966 SF Combined Open Office
Subtotal 397.4 SM 4,277 SF 631.0 SM 6,786 SF
J3 Administrative Support Spaces
Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Administrative Storage Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 27.0 SM 291 SF 32.0 SM 346 SF
J3 Shared Spaces
Conference Room (Large) In shared spaces
Conference Room (Small) In shared spaces
Print Room In shared spaces
Documents Control and Mail Distribution In shared spaces
Break Room In shared spaces
J3 Total 118 424.4 SM 4,568 SF 663.0 SM 7,132 SF
5/12/2026 2 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
J4 - Logistics and Transportation Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS
Open Office (Loistics Operations and Plans Branch) Open 21 21 3.3 SM 69.3 SM 36 SF 746 SF 60% 111.0 SM 1,194 SF Combined Open Office
Open Office (Movement and Transportation Branch) Open 19 19 3.3 SM 62.7 SM 36 SF 675 SF 60% 100.0 SM 1,080 SF Combined Open Office
Open Office (Joint Engineer Branch) Open 6 6 3.3 SM 19.8 SM 36 SF 213 SF 60% 32.0 SM 341 SF Combined Open Office
Open Office (Joint Medical Branch) Open 6 6 3.3 SM 19.8 SM 36 SF 213 SF 60% 32.0 SM 341 SF Combined Open Office
Subtotal 189.5 SM 2,039 SF 299.0 SM 3,206 SF
J4 Administrative Support Spaces
Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Interview Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Administrative Storage Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Secure Storage Room Enclosed 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 42.0 SM 614 SF 49.0 SM 708 SF
J4 Shared Spaces
Conference Room (Medium) In shared spaces
Print Room In shared spaces
Documents Control and Mail Distribution In shared spaces
Break Room In shared spaces
J4 Total 55 231.5 SM 2,653 SF 348.0 SM 3,914 SF
J6 - Cyber/Information Systems Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Executive Assistant Space Open 3 3 3.3 SM 9.9 SM 36 SF 107 SF 60% 16.0 SM 171 SF Workstation outside of ACOS
Open Office (Plans and Operations Branch) Open 12 12 3.3 SM 39.6 SM 36 SF 426 SF 60% 63.0 SM 682 SF Combined Open Office
Open Office (Comm and Info Sys Enablement Branch) Open 10 10 3.3 SM 33.0 SM 36 SF 355 SF 60% 53.0 SM 568 SF Combined Open Office
Open Office (Cyber Defense Branch) Open 7 7 3.3 SM 23.1 SM 36 SF 249 SF 60% 37.0 SM 398 SF Combined Open Office
Subtotal 116.9 SM 1,258 SF 182.0 SM 1,955 SF
J6 Administrative Support Spaces
Collaboration Area Open 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Storage Room Enclosed 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Secure Storage Room Enclosed 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 42.0 SM 452 SF 49.0 SM 527 SF
J6 Shared Spaces
Conference Room (Medium) In shared spaces
Print Room In shared spaces
Documents Control and Mail Distribution In shared spaces
Break Room In shared spaces
J6 Total 33 158.9 SM 1,710 SF 231.0 SM 2,482 SF
5/12/2026 3 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
J5/J9 Deputy Chief of Staff (DCOS)
DCOS Private 1 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
TS and SIPR
Each office should have table and chairs
Shared Office Open 3 1 22.5 SM 22.5 SM 242 SF 242 SF 12% 25.0 SM 271 SF Workstations
Subtotal 4 37.5 SM 404 SF 42.0 SM 452 SF
J5/9 DCOS Support Spaces
Collaboration Area Open - 1 6.0 SM 6.0 SM 65 SF 65 SF 12% 7.0 SM 72 SF For short briefing and discussion
Admin Storage Enclosed - 1 7.5 SM 7.5 SM 81 SF 81 SF 12% 8.0 SM 90 SF
Subtotal 13.5 SM 145 SF 15.0 SM 162 SF
J5/9 DCOS Shared Spaces
Conference Room (Small) In shared spaces
Print Room In shared spaces
Break Room In shared spaces
J5/9DCOS Total 4 51.0 SM 549 SF 57.0 SM 614 SF
J5/J9 Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS
Open Office (Plans Branch) Open 25 25 3.3 SM 82.5 SM 36 SF 888 SF 60% 132.0 SM 1,421 SF Combined Open Office
Open Office (Policy Branch) Open 7 7 3.3 SM 23.1 SM 36 SF 249 SF 60% 37.0 SM 398 SF Combined Open Office
Open Office (Planning Support and Coordination Branch) Open 8 8 3.3 SM 26.4 SM 36 SF 284 SF 60% 42.0 SM 455 SF Combined Open Office
Open Office (J9 Branch) Open 8 8 3.3 SM 26.4 SM 36 SF 284 SF 60% 42.0 SM 455 SF Combined Open Office
Subtotal 176.3 SM 1,897 SF 277.0 SM 2,979 SF
J5/9 Administrative Support Spaces
Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Storage Space Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 27.0 SM 291 SF 32.0 SM 346 SF
J5/9 Shared Spaces
Conference Room (Small) In shared spaces
Classroom (Medium) In shared spaces
Print Room In shared spaces
Documents Control and Mail Distribution In shared spaces
Break Room In shared spaces
J5/9 Total 51 203.3 SM 2,188 SF 309.0 SM 3,325 SF
5/12/2026 4 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
J7 - Joint Force Development Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS
Open Office (Training and Exercise Policy, Programming and
Deterrence Branch) Open 6 6 3.3 SM 19.8 SM 36 SF 213 SF 60% 32.0 SM 341 SF Workstations
Open Office (Training Exercise Delivery Branch) Open 13 13 3.3 SM 42.9 SM 36 SF 462 SF 60% 69.0 SM 739 SF
Open Office (Doctrine and Lessons Learned Branch) Open 7 7 3.3 SM 23.1 SM 36 SF 249 SF 60% 37.0 SM 398 SF
Subtotal 103.7 SM 1,116 SF 162.0 SM 1,728 SF
J7 Administrative Support Spaces
Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Breakout Room (Medium) Enclosed - 3 20.0 SM 60.0 SM 215 SF 646 SF 12% 67.0 SM 723 SF
Storage Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 87.0 SM 936 SF 99.0 SM 1,069 SF
J7 Shared Spaces
Conference Room (Medium) In shared spaces
Classroom (Medium) In shared spaces
Print Room In shared spaces
Documents Control and Mail Distribution In shared spaces
Break Room In shared spaces
J7 Total 29 190.7 SM 2,052 SF 261.0 SM 2,797 SF
NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) NCIA Office Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs
Open Office (NCIA - CSU) Open 36 36 3.3 SM 118.8 SM 36 SF 1,279 SF 60% 190.0 SM 2,046 SF
Subtotal 130.1 SM 1,400 SF 203.0 SM 2,182 SF
NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) Support Spaces
Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF
Conference Room (Small) Enclosed - 1 40.0 SM 40.0 SM 431 SF 431 SF 12% 45.0 SM 482 SF VTC, VOIP, AV (NU and NS)
Print Room Enclosed - 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF
Administration Storage Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Help Desk Enclosed - 1 5.0 SM 5.0 SM 54 SF 54 SF 12% 6.0 SM 60 SF Provides Customer Support - includes window
Equipment Shelves Enclosed - 1 3.7 SM 3.7 SM 40 SF 40 SF 12% 4.0 SM 45 SF Near Help Desk
Subtotal 87.0 SM 936 SF 100.0 SM 1,069 SF
NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) Shared Spaces
Break Room In shared spaces
NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) Total 37 217.0 SM 2,336 SF 303.0 SM 3,251 SF
NSE
Shared Office - 4 persons Enclosed 16 4 13.2 SM 52.8 SM 142 SF 568 SF 28% 68.0 SM 727 SF 4 desks
Shared Office - 2 persons Enclosed 10 5 6.6 SM 33.0 SM 71 SF 355 SF 28% 42.0 SM 455 SF 2 desks
Separate Communications Room Enclosed - 1 7.4 SM 7.4 SM 80 SF 80 SF 12% 8.0 SM 90 SF
NSE Total 26 93.2 SM 1,004 SF 118.0 SM 1,272 SF
5/12/2026 5 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
Bid Option Large Private Office Private 1 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF
Small Private Office Private 9 9 11.3 SM 101.7 SM 122 SF 1,095 SF 12% 114.0 SM 1,226 SF
Open Office Open 138 138 3.3 SM 455.4 SM 36 SF 4,902 SF 60% 729.0 SM 7,843 SF Workstations
Subtotal 572.1 SM 6,158 SF 860.0 SM 9,250 SF
Support Spaces
Conference Room (Medium) Enclosed - 2 64.8 SM 129.6 SM 698 SF 1,395 SF 28% 166.0 SM 1,786 SF
Storage Room Enclosed - 2 7.5 SM 15.0 SM 81 SF 161 SF 12% 17.0 SM 181 SF
Subtotal 144.6 SM 1,556 SF 183.0 SM 1,967 SF
Shared Spaces
Break Room Enclosed - 1 177.6 SM 177.6 SM 1,912 SF 1,912 SF 0% 178.0 SM 1,912 SF
DCOS Total 148 716.7 SM 7,714 SF 1,043.0 SM 11,217 SF
Shared Support Spaces Classroom Enclosed - 1 80.0 SM 80.0 SM 861 SF 861 SF 0% 80.0 SM 861 SF J5/J9, J7
Mailroom Enclosed - 1 20.0 SM 20.0 SM 215 SF 215 SF 0% 20.0 SM 215 SF J2, J3, J4, J6, J5/J9, J7
Break Room Enclosed - 1 582.0 SM 582.0 SM 6,265 SF 6,265 SF 0% 582.0 SM 6,265 SF DCOS, J2, J3, J4, J6, J5/J9 DCOS, J5/J9, J7, NCIA
Print Room Enclosed - 3 15.0 SM 45.0 SM 161 SF 484 SF 0% 45.0 SM 484 SF DCOS, J2, J3, J4, J6, J5/J9 DCOS, J5/J9, J7
Storage (Small) Enclosed - 2 7.5 SM 15.0 SM 81 SF 161 SF 0% 15.0 SM 161 SF
Breakout (Medium) Enclosed - 1 40.0 SM 40.0 SM 431 SF 431 SF 0% 40.0 SM 431 SF
Conference (Large) Enclosed - 1 102.7 SM 102.7 SM 1,105 SF 1,105 SF 0% 103.0 SM 1,105 SF J2, J3
Conference (Medium) Enclosed - 2 64.8 SM 129.5 SM 697 SF 1,394 SF 0% 130.0 SM 1,394 SF J4, J6, J7
Conference (Small) Enclosed - 4 41.5 SM 166.0 SM 447 SF 1,787 SF 0% 166.0 SM 1,787 SF DCOS, J2, J3, J5/J9 DCOS, J5/J9
Shared Support Total 0 1,180.2 SM 12,704 SF 1,181.0 SM 12,703 SF
485 4,616 SM 49,973 SF
633 5,659 SM 61,190 SF
Primary Building Entrance Support Vestibule Enclosed - 1 18.5 SM 18.5 SM 199 SF 199 SF 0% 19.0 SM 199 SF
Security Vestibule Enclosed - 1 9.5 SM 9.5 SM 102 SF 102 SF 0% 10.0 SM 102 SF
Security Office Enclosed 1 1 9.5 SM 9.5 SM 102 SF 102 SF 0% 10.0 SM 102 SF
Reception / Lobby Open - 1 130.0 SM 130.0 SM 1,399 SF 1,399 SF 0% 130.0 SM 1,399 SF
Wellness Room Enclosed - 3 7.5 SM 22.5 SM 81 SF 242 SF 0% 23.0 SM 242 SF
First Aid Room Enclosed - 1 7.5 SM 7.5 SM 81 SF 81 SF 0% 8.0 SM 81 SF
Primary Building Entrance Total 1 197.5 SM 2,126 SF 200.0 SM 2,125 SF
Total Mission Required Seats/Staff - w/ Bid Option Subtotal 1: Total Mission Programmed Area Requirements - w/
Bid Option (Net Assignable)
A d d e d
Total Mission Required Seats/Staff - Base Bid Subtotal 1: Total Mission Programmed Area Requirements -
Base Bid (Net Assignable)
5/12/2026 6 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
Restrooms / Janitors Closets Men's Restroom Enclosed - 2 35.0 SM 70.0 SM 377 SF 753 SF 0% 70.0 SM 753 SF 5 fixtures each (8 required total)
Women's Restroom Enclosed - 2 26.0 SM 52.0 SM 280 SF 560 SF 0% 52.0 SM 560 SF 4 fixtures each (4 required total)
Janitor's Closet Enclosed - 2 3.0 SM 6.0 SM 32 SF 65 SF 0% 6.0 SM 65 SF
Primary Building Entrance Total 0 128.0 SM 1,378 SF 128.0 SM 1,378 SF
Restrooms / Janitors Closets - w/ Bid Option Men's Restroom Enclosed - 1 35.0 SM 35.0 SM 377 SF 377 SF 0% 35.0 SM 377 SF 5 fixtures each
Women's Restroom Enclosed - 1 26.0 SM 26.0 SM 280 SF 280 SF 0% 26.0 SM 280 SF 4 fixtures each
Janitor's Closet Enclosed - 1 3.0 SM 3.0 SM 32 SF 32 SF 0% 3.0 SM 32 SF
Primary Building Entrance Total 0 64.0 SM 689 SF 64.0 SM 689 SF
1 328 SM 3,503 SF
1 392 SM 4,192 SF
486 4,944 SM 53,476 SF
634 6,051 SM 65,382 SF
Communications Telecom Rooms Enclosed - 4 15.0 SM 60.0 SM 161 SF 646 SF 0% 60.0 SM 646 SF 16' x 10'
Primary Building Entrance Total 0 60.0 SM 646 SF 60.0 SM 646 SF
Electrical / Fire Alarm Electrical Main Room Enclosed - 1 42.0 SM 42.0 SM 452 SF 452 SF 0% 42.0 SM 452 SF 15' x 30'
Electrical Room Enclosed - 5 10.0 SM 50.0 SM 108 SF 538 SF 0% 50.0 SM 538 SF 9' x 10'
Electrical Yard (Generator) External - 1 0.0 SM 0.0 SM 0 SF 0 SF 0% 0.0 SM 0 SF 20' x 30' External
Primary Building Entrance Total 0 92.0 SM 990 SF 92.0 SM 990 SF
Mechanical / Plumbing / Fire Supression Mechanical/ Plumbing Room Enclosed - 1 70.0 SM 70.0 SM 753 SF 753 SF 0% 70.0 SM 753 SF 20' x 30', 8' x 8', shafts
Fire Protection Room Enclosed - 1 21.0 SM 21.0 SM 226 SF 226 SF 0% 21.0 SM 226 SF 15' x 15'
Mechanical Yard External - 1 0.0 SM 0.0 SM 0 SF 0 SF 0% 0.0 SM 0 SF 30' x 40' External
Primary Building Entrance Total 0 91.0 SM 980 SF 91.0 SM 979 SF
5,187 SM 56,091 SF
6,294 SM 67,997 SF
Total Building Support and Amenity Seats/Staff - Base Bid Subtotal 2: Total Building Support and Amenity Programmed
Area - Base Bid
Total Programmed Seats/Staff - Base Bid Subtotal 3: Total Net Area Requirements - Base Bid (Subtotal 1
+ Subtotal 2)
Subtotal 4: Base Bid (Subtotal 3 + Comms + Elec/FA + Mech/Plumb/FX + Restrooms/Jan)
Subtotal 4: W/ Bid Option (Subtotal 3 + Comms + Elec/FA + Mech/Plumb/FX + Restrooms/Jan)
Total Programmed Seats/Staff - w/ Bid Option Subtotal 3: Total Net Area Requirements - w/ Bid Option
(Subtotal 1 + Subtotal 2)
Total Building Support and Amenity Seats/Staff - w/ Bid Option Subtotal 2: Total Building Support and Amenity Programmed
Area - w/ Bid Option
5/12/2026 7 of 8
Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir
Mult
NASM
Total
NASF
Subtotal Remarks
Estimate 24% 1,219 SM 13,181 SF
Estimate 8% 415 SM 4,487 SF
Estimate 5% 259 SM 2,805 SF
Estimate 70 SM 35 SM 377 SF
1,928 SM 20,850 SF
Estimate 24% 1,479 SM 15,979 SF
Estimate 8% 504 SM 5,440 SF
Estimate 5% 315 SM 3,400 SF
Estimate 70 SM 35 SM 377 SF
2,332 SM 25,196 SF
Grand Total Program Gross Area - Base Bid 7,115 SM 76,941 SF
Grand Total Program Gross Area - w/ Bid Option 8,626 SM 93,193 SF
Total - Base Bid
Primary Circulation
Building Envelope
Permanent Modular Construction Factor
Building Overhangs and Canopies (Calculated at 1/2 SF)
Primary Circulation
Building Envelope
Permanent Modular Construction Factor
Building Overhangs and Canopies (Calculated at 1/2 SF)
Total - W/ Bid Option
5/12/2026 8 of 8
SC49
SC49A
SC41
SC48
SC139
NH31J
SC51
SC140ASC43
SC142
SC39
SC34
SC44
SC47
SC37
SC35
SC33
SC45
SC32
SC52
SC42
SC139A
SC140
SC46
SC40
SC141
SC36
SC38
BLA
NDY ROAD
FO
RR
ES
TA
L D
RI
VE
BLA
NDY ROAD
FORRESTAL DRIVE
LEYTE AVENUE
CO
RR
EG
ID
OR
A
VE
NU
E
FECHTELER ROAD
FECHTELER ROAD
W
W W
W
W
W
W W
W W
W W
W W
W W
W W
W
W
W W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
W W
W
W W
W
W
W W
W W
W W
W
W
W
W
W
WW
W
W
W
W
W W
W
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W W
W
W W
W W
W W
W
W W
W W
W
W
W
W W
W
W W
W
W
W W
W
W
W
W W
W W
W W
W
W W W W
W
W W
W
W
W
W
W
W
W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W W
W W
W W
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
SA
N
SA
N
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
G
G
G
G
G
G
G G
G
G
G
G
G
G G
G G
G
G
G G
G
G
G
G G
G G
G G
G
G
G
G G
G
G
G
G
G
G
G
G G
G G
G G
G G
E
E
E
E
E
E
E
E
E
E E
E E
E E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E E
E E
E
E E
E E
E
E E E E E
E E
E E
E
E
E
E
E
E E
E E
E E
E E
E E
E
E
E
E
E E E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
E E
E E
E E
E E
E
E
E E
E E
EEEE
E E E E E E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
E E
E E
E E
E
E
E
E
E
E
E
E
E
FI
LE
N
AM
E:
C
:\U se rs \c am pe ri\
DC
\A
CC
Do cs
\A
EC
O M
\B P-
AM
ER
(U S)
-6
0-
JF
C No rfo lk
M od ul ar
C am pu s
DB
R
FP
(N
AT
O
)\P ro je ct
F ile s\
De sig n
Co lla bo ra tio n\
-C
\N
AT
O _C
D1
.d wg
L
AY
O
UT
N
AM
E:
C
D1
P
LO
TT
ED
: W ed ne sd ay , M ay
6,
- 9 :4
4a m
U
SE
R:
C am pe rI
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
N O
T
FO
R C
O N
S
TR
U C
TI
O
N
P R
E L
IM
IN
A
R Y
THIS DRAWING IS FOR REFERENCE ONLY, AND SHOWS THE DESIRED
FUNCTIONAL ARRANGEMENT AND ADJACEMCY FOR EACH DEPARTMENT. ITS
INCLUSION DOES NOT PRECLUDE THE D/B TEAM FROM ALTERING FOR
STRUCTURAL AND/OR MODULAR ACCOMODATIONS
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
LA
NT
N
AV
AL
S U
PP
O
R T
AC
TI
VI
TY
H
AM
PT
O
N R
O
AD
S
FY
S
PE
CI
AL
P
RO
JE
CT
J
FC
N
IN
TE
RI
M M
O
DU
LA
R
CA
M
PU
S
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
UP
PO
RT
A
CT
IV
IT
Y
HA
MP
TO
N
RO
AD
S M
ID
LA
N T
D C
C O
R E
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SEAL
A/E INFO
DRAWFORM REVISION: 04 MAY 2023
SI
TE
D
EM
O
LI
TI
O
N
PL
AN
IPC IPC ACF
AS NOTED
CD101
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
KEYNOTES
A. THE ACTUAL FIELD CONDITIONS AT THE TIME OF CONSTRUCTION MAY
VARY FROM THAT PRESENTED ON THESE PLANS. CONFIRM THE
LOCATION OF ALL ITEMS PRIOR TO START OF CONSTRUCTION.
B. DEMOLITION OF PAVEMENTS INCLUDES AGGREGATE BASE COURSES.
C. PROVIDE SAW CUTS FOR ASPHALT AND CONCRETE DEMOLITION WORK
THAT IS ADJACENT TO EXISTING ASPHALT OR CONCRETE
PAVEMENT/WALKWAYS TO REMAIN.
12 8
1 REMOVE EXISTING CROSSWALK PAVEMENT MARKINGS.
2 DEMOLISH EXISTING CONCRETE WALK.
3 DEMOLISH EXISTING SITE STRUCTURE (GAZEBO).
4 DEMOLISH EXISTING BUILDING AND FOUNDATION.
5 DEMOLISH EXISTING ASPHALT PAVEMENT.
6 REMOVE EXISTING PAVEMENT MARKINGS.
7 DEMOLISH EXISTING GRAVEL PARKING AREA.
8 DEMOLISH EXISTING CONCRETE APRON.
9 DEMOLISH EXISTING WATER LINE.
10 DEMOLISH EXISTING GAS LINE.
11 DEMOLISH EXISTING SANITARY SEWER.
12 CAP OR PLUG EXISTING PIPE.
13 DEMOLISH ALL UTILITY SERVICES ASSOCIATED WITH EXISTING
STRUCTURES.
14 PROTECT EXISTING WATER LINE TO REMAIN DURING
CONSTRUCTION.
15 DEMOLISH EXISTING UNDERGROUND ELECTRICAL.
16 DEMOLISH EXISTING LIGHT.
17 CAP AND ABANDON EXISTING PIPING BELOW
ROADWAY.
NORTH
1"=40' 40' 20' 0 40' 80'
AM
EN
DM
EN
T
5/
CM
C
5/
/2
SC49
SC49A
SC41
SC48
SC139
NH31J
SC51
SC140ASC43
SC44
SC47
SC52
SC42
SC139A
SC140
SC46
SC40
BLA
NDY ROAD
FO
RR
ES
TA
L D
RI
VE
BLA
NDY ROAD
FORRESTAL DRIVE
LEYTE AVENUE
CO
RR
EG
ID
OR
A
VE
NU
E
FECHTELER ROAD
FECHTELER ROAD
X
X X
X
X
X
X
X X
X X
X X
X X
X
X
X X
X X
X
TEMPORARY PARKING GARAGE
(4 TIERS)
NATO JFCN INTERIM BUILDING
25'
20'
20'
R30'
R
R2 6'
R
'R20'R
R26'
R30'
R10'
20'
20'
10'
14'
98'
20'
FI
LE
N
AM
E:
C
:\U se rs \c am pe ri\
DC
\A
CC
Do cs
\A
EC
O M
\B P-
AM
ER
(U S)
-6
0-
JF
C No rfo lk
M od ul ar
C am pu s
DB
R
FP
(N
AT
O
)\P ro je ct
F ile s\
De sig n
Co lla bo ra tio n\
-C
\N
AT
O _C
S1
_C O
A2 .d wg L
AY
O
UT
N
AM
E:
C S1
P
LO
TT
ED
: W ed ne sd ay
, M ay
6,
- 9
:4 3a m U
SE
R:
C am pe rI
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
N O
T
FO
R C
O N
S
TR
U C
TI
O
N
P R
E L
IM
IN
A
R Y
THIS DRAWING IS FOR REFERENCE ONLY, AND SHOWS THE DESIRED
FUNCTIONAL ARRANGEMENT AND ADJACEMCY FOR EACH DEPARTMENT. ITS
INCLUSION DOES NOT PRECLUDE THE D/B TEAM FROM ALTERING FOR
STRUCTURAL AND/OR MODULAR ACCOMODATIONS
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
LA
NT
N
AV
AL
S U
PP
O
R T
AC
TI
VI
TY
H
AM
PT
O
N R
O
AD
S
FY
S
PE
CI
AL
P
RO
JE
CT
J
FC
N
IN
TE
RI
M M
O
DU
LA
R
CA
M
PU
S
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
UP
PO
RT
A
CT
IV
IT
Y
HA
MP
TO
N
RO
AD
S M
ID
LA
N T
D C
C O
R E
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SEAL
A/E INFO
DRAWFORM REVISION: 04 MAY 2023
SI
TE
P
LA
N
IPC IPC ACF
AS NOTED
CS101
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
KEYNOTES
A. GROUNDWATER MAY BE ENCOUNTERED FOR ALL EXCAVATIONS. PROVIDE
DEWATERING AS REQUIRED.
6 6
6 16
LEGEND
BUILDING FOOTPRINT
ASPHALT PAVEMENT
CONCRETE SIDEWALK
STORMWATER MANAGEMENT AREA
HEAVY DUTY CONCRETE
PAVEMENT
1 33-FT UNOBSTRUCTED SPACE SETBACK.
2 10-FT BUILDING SETBACK.
3 30-FT EXISTING BUILDING SETBACK.
4 100m (328-FT) NATO SETBACK FROM PERIMETER FENCE.
5 50-FT SETBACK FROM PERIMETER FENCE.
6 CONCRETE WALK. 8-FT MINIMUM WIDTH AT ENTRANCES AND
EXITS. 6-FT MINIMUM WIDTH ALL OTHERS. MATCH EXISTING
WALK WIDTH WHERE NEW CONCRETE IS PARALLEL WITH
EXISTING.
7 20-FT WIDE FIRE ACCESS ROAD (HEAVY DUTY CONCRETE
PAVEMENT).
8 ASPHALT PAVEMENT.
9 BUS PARKING.
10 AREA RESERVED FOR STORMWATER MANAGEMENT.
11 CHAINLINK FENCE.
12 DOUBLE LEAF SWING GATE WITH FIRE DEPARTMENT ACCESS
BOX.
13 PEDESTRIAN TURNSTILE WITH CAC CARD READER.
14 CROSSWALK PAVEMENT MARKING.
15 NO PARKING PAVEMENT MARKING FOR FIRE LANE.
16 ACCESSIBLE PARKING PAVEMENT MARKING AND SIGNAGE.
17 ENTRANCE CANOPY
NORTH
1"=40' 40' 20' 0 40' 80'
AM
EN
DM
EN
T
CM
C
5/
/2
X
X
X
X
X
X
X X
X
X X
X X
X
X
X X
X X
TEMPORARY PARKING GARAGE
(4 TIERS)
NATO JFCN INTERIM BUILDING
SC49
SC49A
SC138
SC41
SC48
SC139
SC138A
NH31J
SC50
SC51
SC140ASC43
SC53
NH31
SC44
SC47
SC52
SC42
SC139A
SC23
SC11
SC10
SC140
SC46
SC40
SC137
SC31
SC136
BLA
NDY ROAD
FO
RR
ES
TA
L D
RI
VE
BLA
NDY ROAD
FORRESTAL DRIVE
LEYTE AVENUE
CO
RR
EG
ID
OR
A
VE
NU
E
FECHTELER ROAD
FECHTELER ROAD
W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
W
W
W
W
W
W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
W
W W
W W
W
W
W
W W
W
W
W
W W W W
W W
W W
W W
W W
W W
W W
W
W
W
W W
W W
W
W W
W
W
W W
W
W W
W W
W
W
W W
W W
W W
W W
W W
W W
W
W W
W
W
W
W W W W W
W W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W W
W
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
S
S
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
SA
N
SA
N
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SA
N
SAN
SAN
SAN
SAN
SAN
SAN
SAN
G
G
G
G
G
G
G
G
G
G G
G G
G
G
G
G
G
G
G
G G
G
G
G
G
G
G
G
G
G G
G
E
E
E
E
E
E
E E
E E
E E
E
E E
E E
E
E
E E
E E
E E
E E
E E E E
E E
E E
E E
E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
E
E
E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E E
E E
E E
E E
E E
E
EE
E E
E E
E
E E
E E
E
E E
E
E
E
E E
E
E E
E E
E E
E E
E
E E
E E
E E
E
E
E E
E E
EEEE
E E
E E
E E E E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E E
E
E
E
E
E
E
E
E E
E E
E
E
E
EE
E E
E
E
E
E
E
E
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
W
W
W
PIV
PIV
C
C
C
UGC
C
U G
C
W
W W W
W W
C
W
GAS GAS GAS GAS
E
E
E
E E
E E
E E
E
E
E
E E
E E
E
E
E
E
EEEE
E
E
E
FI
LE
N
AM
E:
C
:\U se rs \c am pe ri\
DC
\A
CC
Do cs
\A
EC
O M
\B P-
AM
ER
(U S)
-6
0-
JF
C No rfo lk
M od ul ar
C am pu s
DB
R
FP
(N
AT
O
)\P ro je ct
F ile s\
De sig n
Co lla bo ra tio n\
-C
\N
AT
O _C
U1
_C O
A2 .d wg L
AY
O
UT
N
AM
E:
C U1
P
LO
TT
ED
: W ed ne sd ay
, M ay
6,
- 9
:4 2a m U
SE
R:
C am pe rI
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
N O
T
FO
R C
O N
S
TR
U C
TI
O
N
P R
E L
IM
IN
A
R Y
THIS DRAWING IS FOR REFERENCE ONLY, AND SHOWS THE DESIRED
FUNCTIONAL ARRANGEMENT AND ADJACEMCY FOR EACH DEPARTMENT. ITS
INCLUSION DOES NOT PRECLUDE THE D/B TEAM FROM ALTERING FOR
STRUCTURAL AND/OR MODULAR ACCOMODATIONS
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
LA
NT
N
AV
AL
S U
PP
O
R T
AC
TI
VI
TY
H
AM
PT
O
N R
O
AD
S
FY
S
PE
CI
AL
P
RO
JE
CT
J
FC
N
IN
TE
RI
M M
O
DU
LA
R
CA
M
PU
S
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
UP
PO
RT
A
CT
IV
IT
Y
HA
MP
TO
N
RO
AD
S M
ID
LA
N T
D C
C O
R E
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SEAL
A/E INFO
DRAWFORM REVISION: 04 MAY 2023
NORTH
SI
TE
U
TI
LI
TY
P
LA
N
IPC IPC ACF
AS NOTED
CU101
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
KEYNOTES
A. PROVIDE POST-INDICATOR VALVES FOR FIRE SERVICE CONNECTIONS.
B. PROVIDE ISOLATION GATE VALVES ON ALL BRANCH CONNECTIONS TO
NEW AND EXISTING WATER LINES.
C. PROVIDE SITE LIGHTING FOR NEW FACILITIES IN ACCORDANCE WITH THE
RFP DOCUMENTS.
D. FIELD VERIFY LOCATION OF EXISTING UTILITIES AND RELOCATE AS
NECESSARY WHERE IN CONFLICT WITH PROPOSED WORK.
E. GROUNDWATER MAY BE ENCOUNTERED FOR ALL EXCAVATIONS. PROVIDE
DEWATERING AS REQUIRED.
50' 25' 0 50' 100' 1"=50'
LEGEND
SANITARY SEWER
SANITARY SEWER MANHOLE
WATER MAIN
ISOLATION GATE VALVE
POST-INDICATOR VALVEPIV
TELECOMMUNICATION DUCTBANKUGC
C TELECOMMUNICATION MANHOLE
1 APPROXIMATE LOCATION OF EXISTING COMMUNICATION
MANHOLE.
2 3-WAY TELECOMM DUCTBANK.
3 6" FIRE WATER SERVICE.
4 POST-INDICATOR VALVE.
5 8" WATER MAIN.
6 2" DOMESTIC WATER SERVICE.
7 CONNECT TO EXISTING 8" WATER MAIN.
8 4" SANITARY SEWER LATERAL.
9 6" SANITARY SEWER.
10 CONNECT TO EXISTING SANITARY SEWER MANHOLE.
11 8" FIRE WATER SERVICE.
12 1.5" NATURAL GAS SERVICE.
13 CONNECT TO EXISTING NATURAL GAS.
14 PROVIDE GENERATOR.
15 PROVIDE MODULAR PAD-MOUNTED TRANSFORMER.
16 PROVIDE 35kV ELECTRICAL DUCTBANK.
17 CONNECT TO EXISTING 35kV ELECTRICAL DUCTBANK.
18 EXISTING 4-WAY SWITCH ELECTRICAL POINT OF CONNECTION
FOR BOTH FACILITIES.
SAN
W
FIRE HYDRANT
ELECTRICAL MANHOLE
E
NATURAL GASGAS
AM
EN
DM
EN
T
5/8 /20
CM
C 5/
/2
| Continuation Cover Sheet |
| Space Program |
| Drawings |
File details come from the government source that posted it. Updated .