Attachment M - JFCN IMF DB RFP - Amended.pdf

PDF 14 MB Posted

Attached to
DESIGN-BUILD P1678 NATO JFCNF PHASE II INTERIM MODULAR FACILITY, NSA NORFOLK, VA
Solicitation number
N4008525R2638
Issued by

About this file

This document is a Space Requirements and Programming Plan for the NATO Joint Force Command Norfolk (JFCN) Interim Modular Facility at Naval Support Activity Hampton Roads, Norfolk, Virginia, identifying detailed space allocations across multiple organizational departments. The facility encompasses 486 total personnel seats in the base bid configuration and 634 seats with the bid option, requiring a total net assignable area of 4,944 square meters (53,476 square feet) for base bid and 6,051 square meters (65,382 square feet) with bid option. The facility supports multiple joint operational divisions including the Joint Operations Center (JOC) with 40 personnel, Deputy Chief of Staff (DCOS) with 4 personnel, Intelligence Section (J2) with 92 personnel, Operations Section (J3) with 118 personnel, Logistics and Transportation (J4) with 55 personnel, Cyber/Information Systems (J6) with 33 personnel, Joint Force Development (J7) with 29 personnel, Plans and Policy (J5/J9) with 51 personnel, NATO Communications & Information Agency (NCIA) with 37 personnel, and National Support Element (NSE) with 26 personnel, along with shared support spaces and building infrastructure.

The programming plan specifies detailed room-by-room allocations with measurements in net square meters (NSM) and net square feet (NSF), including private offices, open office areas, conference and breakout rooms, administrative storage, and support facilities. Building support areas encompass 328 square meters (3,503 square feet) for base bid and 392 square meters (4,192 square feet) with bid option, including shared restrooms, telecommunications rooms, electrical infrastructure, mechanical and plumbing systems, and a classified communications facility. The gross area estimate for the base bid totals 7,115 square meters (76,841 square feet), while the bid option configuration totals 8,626 square meters (93,193 square feet), incorporating primary circulation (24 percent), building envelope (8 percent), permanent modular construction factors (5 percent), and building overhangs/canopies. Supporting documentation includes site demolition, site utility, and landscaping plans, with the facility designed as a permanent modular construction to accommodate NATO operational requirements for command and control operations at Naval Station Norfolk.

View the file

Other files

File Type Posted
Updated Attachment I - P1678 NATO Price Proposal Form REV2.docx DOCX document
Amendment 0010 P1678 NATO.pdf PDF
Amendment 0009 P1678 NATO.pdf PDF
Updated Attachment I - P1678 NATO Price Proposal Form REV1.docx DOCX document
Amendment 0009 NATO DB RFP Civil Sheets.pdf PDF
Amendment 0009 NATO Room Data Sheets.pdf PDF
DB RFP Attachment L - Regional Environmental Checklist.pdf PDF
Amendment 0008 P1678 NATO.pdf PDF
Amendment 0007 P1678 NATO.pdf PDF
Attachment N - P1678 Site Visit Log.pdf PDF
Amendment 0006 P1678 NATO.pdf PDF
Amendment 0005 P1678 NATO.pdf PDF
Attachment G - Small Business Subcontracting Plan (SBSP).docx DOCX document
Attachment L - ODP_ML.xlsx XLSX spreadsheet
Attachment E- Historical Small Business Utilization.docx DOCX document
Attachment F - Small Business Participation Commitment Document.docx DOCX document
Attachment J - SECNAV 5512.pdf PDF
Attachment I - P1678 NATO Price Proposal Form.docx DOCX document
Attachment K - NSA HR Main Site Base Map.pdf PDF
CJA ML-23-80 - Redacted.pdf PDF
Amendment 0004 P1678 NATO.pdf PDF
Amendment 0003 P1678 NATO.pdf PDF
Amendment 0002 P1678 NATO.pdf PDF
Amendment 0002 Pre-Proposal Inquiries.pdf PDF
Amendment 0001 Pre-Proposal Inquiries.pdf PDF
Updated Attachment C - Experience Project Data Sheet.pdf PDF
Amendment 0001 P1678 NATO.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment D - Past Performance Questionnaire.pdf PDF
Solicitation - N4008525R2638.pdf PDF
Attachment A - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
Attachment C - Experience Project Data Sheet.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NATO JFCNF Interim Modular Facility Naval Support Activity

Hampton Roads, Norfolk, Virginia Work Order Number 1810892

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

Joint Operations Center (JOC) Shared Office Private 2 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Battle Watch C (BWC) Shift Director Private 1 1 7.5 SM 7.5 SM 81 SF 81 SF 12% 8.0 SM 90 SF

Deputy Chief of Operations (DCOS) Private 1 3 7.5 SM 22.5 SM 81 SF 242 SF 12% 25.0 SM 271 SF One office each for Operations, Plans and INTEL

Watch Floor (Workstations) Open 34 34 3.3 SM 112.2 SM 36 SF 1,208 SF 60% 180.0 SM 1,932 SF

Training Room Private 2 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF 2 NS and 2 NU

JOC Vestibule Enclosed - 1 5.6 SM 5.6 SM 60 SF 60 SF 0% 6.0 SM 60 SF

Subtotal 177.8 SM 1,914 SF 253.0 SM 2,715 SF

JOC Support Spaces

Breakout Room (Small) Enclosed - 3 6.7 SM 20.0 SM 72 SF 215 SF 12% 22.0 SM 241 SF

Breakout Room (Large) Enclosed - 1 80.0 SM 80.0 SM 861 SF 861 SF 12% 90.0 SM 964 SF

Printer Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Briefing Room Enclosed - 1 40.0 SM 40.0 SM 431 SF 431 SF 12% 45.0 SM 482 SF

Document Storage Enclosed - 1 10.0 SM 10.0 SM 108 SF 108 SF 12% 11.0 SM 121 SF

Storage Enclosed - 1 10.0 SM 10.0 SM 108 SF 108 SF 12% 11.0 SM 121 SF

Storage for bunks/cots, emergency supplies, tables, and chairs

Mechanical Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Flex Spaces Enclosed - 3 13.3 SM 40.0 SM 143 SF 430 SF 12% 45.0 SM 482 SF Bunk room, conference room

Subtotal 230.0 SM 2,476 SF 258.0 SM 2,773 SF

JOC Support Spaces - Adj to JOC/COC

Coordination Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Shower Rooms Enclosed - 2 15.0 SM 30.0 SM 161 SF 323 SF 12% 34.0 SM 362 SF Men's and Women's

Locker Rooms Enclosed - 2 17.5 SM 35.0 SM 188 SF 377 SF 12% 39.0 SM 422 SF Men's and Women's

Janitor Storage Enclosed - 1 6.0 SM 6.0 SM 65 SF 65 SF 12% 7.0 SM 72 SF

Break Room Open - 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF

11.25m2 is the minimum, space allocation 1.2 sm per pn

Subtotal 97.3 SM 1,047 SF 110.0 SM 1,173 SF

JOC Total 40 505.0 SM 5,436 SF 621.0 SM 6,661 SF

Deputy Chief of Staff (DCOS) DCOS Private Office Private 1 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF Each office to have table and chairs (TS & SIPR)

Shared Office Open 3 3 3.3 SM 9.9 SM 36 SF 107 SF 60% 16.0 SM 171 SF Workstations

Subtotal 24.9 SM 268 SF 33.0 SM 352 SF

DCOS Support Spaces

Collaboration Area Open - 1 6.0 SM 6.0 SM 65 SF 65 SF 28% 8.0 SM 83 SF For short briefing and discussion

Admin Storage Enclosed - 1 7.5 SM 7.5 SM 81 SF 81 SF 12% 8.0 SM 90 SF

Subtotal 13.5 SM 145 SF 16.0 SM 173 SF

DCOS Shared Spaces

Conference Room (Small) In shared spaces

Print Room In shared spaces

Break Room In shared spaces

DCOS Total 4 38.4 SM 413 SF 49.0 SM 525 SF

5/12/2026 1 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

J2 - INTEL

Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS

Open Office (Joint Intel Collection Branch) Open 20 20 3.3 SM 66.0 SM 36 SF 710 SF 60% 106.0 SM 1,137 SF Combined Open Office

Open Office (Joint Intel Direction Support Branch) Open 25 25 3.3 SM 82.5 SM 36 SF 888 SF 60% 132.0 SM 1,421 SF Combined Open Office

Open Office (Joint Intelligence J2/J3) Open 19 19 3.3 SM 62.7 SM 36 SF 675 SF 12% 70.0 SM 756 SF Combined Open Office

Open Office (Joint Intelligence Processing and Assessment) Open 21 21 3.3 SM 69.3 SM 36 SF 746 SF 60% 111.0 SM 1,194 SF Combined Open Office

Intel Vault Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF

EMB Shared 3 1 3.3 SM 3.3 SM 36 SF 36 SF 60% 5.0 SM 57 SF Connected to the Intel Vault

Subtotal 298.4 SM 3,368 SF 443.0 SM 4,951 SF

J2 Administrative Support Spaces

Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Administrative Storage Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 27.0 SM 291 SF 32.0 SM 346 SF

J2 Shared Spaces

Conference Room (Large) In shared spaces

Conference Room (Small) In shared spaces

Print Room In shared spaces

Documents Control and Mail Distribution In shared spaces

Break Room In shared spaces

J2 Total 92 325.4 SM 3,659 SF 475.0 SM 5,297 SF

J3 - Operations Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS

Open Office (J3/3 Current Operations Branch) Open 47 47 3.3 SM 155.1 SM 36 SF 1,669 SF 60% 248.0 SM 2,671 SF Combined Open Office

Open Office (J3/3 Coordination and Synchronization Branch) Open 20 20 3.3 SM 66.0 SM 36 SF 710 SF 60% 106.0 SM 1,137 SF Combined Open Office

Open Office (Joint Effects Branch) Open 15 15 3.3 SM 49.5 SM 36 SF 533 SF 60% 79.0 SM 853 SF Combined Open Office

Open Office (Force Protection Branch) Open 16 16 3.3 SM 52.8 SM 36 SF 568 SF 60% 84.0 SM 909 SF Combined Open Office

Open Office (Joint Assessment Branch) Open 17 17 3.3 SM 56.1 SM 36 SF 604 SF 60% 90.0 SM 966 SF Combined Open Office

Subtotal 397.4 SM 4,277 SF 631.0 SM 6,786 SF

J3 Administrative Support Spaces

Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Administrative Storage Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 27.0 SM 291 SF 32.0 SM 346 SF

J3 Shared Spaces

Conference Room (Large) In shared spaces

Conference Room (Small) In shared spaces

Print Room In shared spaces

Documents Control and Mail Distribution In shared spaces

Break Room In shared spaces

J3 Total 118 424.4 SM 4,568 SF 663.0 SM 7,132 SF

5/12/2026 2 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

J4 - Logistics and Transportation Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS

Open Office (Loistics Operations and Plans Branch) Open 21 21 3.3 SM 69.3 SM 36 SF 746 SF 60% 111.0 SM 1,194 SF Combined Open Office

Open Office (Movement and Transportation Branch) Open 19 19 3.3 SM 62.7 SM 36 SF 675 SF 60% 100.0 SM 1,080 SF Combined Open Office

Open Office (Joint Engineer Branch) Open 6 6 3.3 SM 19.8 SM 36 SF 213 SF 60% 32.0 SM 341 SF Combined Open Office

Open Office (Joint Medical Branch) Open 6 6 3.3 SM 19.8 SM 36 SF 213 SF 60% 32.0 SM 341 SF Combined Open Office

Subtotal 189.5 SM 2,039 SF 299.0 SM 3,206 SF

J4 Administrative Support Spaces

Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Interview Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Administrative Storage Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Secure Storage Room Enclosed 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 42.0 SM 614 SF 49.0 SM 708 SF

J4 Shared Spaces

Conference Room (Medium) In shared spaces

Print Room In shared spaces

Documents Control and Mail Distribution In shared spaces

Break Room In shared spaces

J4 Total 55 231.5 SM 2,653 SF 348.0 SM 3,914 SF

J6 - Cyber/Information Systems Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Executive Assistant Space Open 3 3 3.3 SM 9.9 SM 36 SF 107 SF 60% 16.0 SM 171 SF Workstation outside of ACOS

Open Office (Plans and Operations Branch) Open 12 12 3.3 SM 39.6 SM 36 SF 426 SF 60% 63.0 SM 682 SF Combined Open Office

Open Office (Comm and Info Sys Enablement Branch) Open 10 10 3.3 SM 33.0 SM 36 SF 355 SF 60% 53.0 SM 568 SF Combined Open Office

Open Office (Cyber Defense Branch) Open 7 7 3.3 SM 23.1 SM 36 SF 249 SF 60% 37.0 SM 398 SF Combined Open Office

Subtotal 116.9 SM 1,258 SF 182.0 SM 1,955 SF

J6 Administrative Support Spaces

Collaboration Area Open 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Storage Room Enclosed 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Secure Storage Room Enclosed 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 42.0 SM 452 SF 49.0 SM 527 SF

J6 Shared Spaces

Conference Room (Medium) In shared spaces

Print Room In shared spaces

Documents Control and Mail Distribution In shared spaces

Break Room In shared spaces

J6 Total 33 158.9 SM 1,710 SF 231.0 SM 2,482 SF

5/12/2026 3 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

J5/J9 Deputy Chief of Staff (DCOS)

DCOS Private 1 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

TS and SIPR

Each office should have table and chairs

Shared Office Open 3 1 22.5 SM 22.5 SM 242 SF 242 SF 12% 25.0 SM 271 SF Workstations

Subtotal 4 37.5 SM 404 SF 42.0 SM 452 SF

J5/9 DCOS Support Spaces

Collaboration Area Open - 1 6.0 SM 6.0 SM 65 SF 65 SF 12% 7.0 SM 72 SF For short briefing and discussion

Admin Storage Enclosed - 1 7.5 SM 7.5 SM 81 SF 81 SF 12% 8.0 SM 90 SF

Subtotal 13.5 SM 145 SF 15.0 SM 162 SF

J5/9 DCOS Shared Spaces

Conference Room (Small) In shared spaces

Print Room In shared spaces

Break Room In shared spaces

J5/9DCOS Total 4 51.0 SM 549 SF 57.0 SM 614 SF

J5/J9 Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS

Open Office (Plans Branch) Open 25 25 3.3 SM 82.5 SM 36 SF 888 SF 60% 132.0 SM 1,421 SF Combined Open Office

Open Office (Policy Branch) Open 7 7 3.3 SM 23.1 SM 36 SF 249 SF 60% 37.0 SM 398 SF Combined Open Office

Open Office (Planning Support and Coordination Branch) Open 8 8 3.3 SM 26.4 SM 36 SF 284 SF 60% 42.0 SM 455 SF Combined Open Office

Open Office (J9 Branch) Open 8 8 3.3 SM 26.4 SM 36 SF 284 SF 60% 42.0 SM 455 SF Combined Open Office

Subtotal 176.3 SM 1,897 SF 277.0 SM 2,979 SF

J5/9 Administrative Support Spaces

Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Storage Space Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 27.0 SM 291 SF 32.0 SM 346 SF

J5/9 Shared Spaces

Conference Room (Small) In shared spaces

Classroom (Medium) In shared spaces

Print Room In shared spaces

Documents Control and Mail Distribution In shared spaces

Break Room In shared spaces

J5/9 Total 51 203.3 SM 2,188 SF 309.0 SM 3,325 SF

5/12/2026 4 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

J7 - Joint Force Development Assistant Chief of Staff (ACOS) Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Executive Assistant Space Open 2 2 3.3 SM 6.6 SM 36 SF 71 SF 60% 11.0 SM 114 SF Workstation outside of ACOS

Open Office (Training and Exercise Policy, Programming and

Deterrence Branch) Open 6 6 3.3 SM 19.8 SM 36 SF 213 SF 60% 32.0 SM 341 SF Workstations

Open Office (Training Exercise Delivery Branch) Open 13 13 3.3 SM 42.9 SM 36 SF 462 SF 60% 69.0 SM 739 SF

Open Office (Doctrine and Lessons Learned Branch) Open 7 7 3.3 SM 23.1 SM 36 SF 249 SF 60% 37.0 SM 398 SF

Subtotal 103.7 SM 1,116 SF 162.0 SM 1,728 SF

J7 Administrative Support Spaces

Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Breakout Room (Medium) Enclosed - 3 20.0 SM 60.0 SM 215 SF 646 SF 12% 67.0 SM 723 SF

Storage Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 87.0 SM 936 SF 99.0 SM 1,069 SF

J7 Shared Spaces

Conference Room (Medium) In shared spaces

Classroom (Medium) In shared spaces

Print Room In shared spaces

Documents Control and Mail Distribution In shared spaces

Break Room In shared spaces

J7 Total 29 190.7 SM 2,052 SF 261.0 SM 2,797 SF

NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) NCIA Office Private 1 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF Table and chairs

Open Office (NCIA - CSU) Open 36 36 3.3 SM 118.8 SM 36 SF 1,279 SF 60% 190.0 SM 2,046 SF

Subtotal 130.1 SM 1,400 SF 203.0 SM 2,182 SF

NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) Support Spaces

Collaboration Area Open - 1 12.0 SM 12.0 SM 129 SF 129 SF 28% 15.0 SM 165 SF

Conference Room (Small) Enclosed - 1 40.0 SM 40.0 SM 431 SF 431 SF 12% 45.0 SM 482 SF VTC, VOIP, AV (NU and NS)

Print Room Enclosed - 1 11.3 SM 11.3 SM 121 SF 121 SF 12% 13.0 SM 136 SF

Administration Storage Room Enclosed - 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Help Desk Enclosed - 1 5.0 SM 5.0 SM 54 SF 54 SF 12% 6.0 SM 60 SF Provides Customer Support - includes window

Equipment Shelves Enclosed - 1 3.7 SM 3.7 SM 40 SF 40 SF 12% 4.0 SM 45 SF Near Help Desk

Subtotal 87.0 SM 936 SF 100.0 SM 1,069 SF

NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) Shared Spaces

Break Room In shared spaces

NATO Communications & Information Agency (NCIA) CIS Support Units (CSU) Total 37 217.0 SM 2,336 SF 303.0 SM 3,251 SF

NSE

Shared Office - 4 persons Enclosed 16 4 13.2 SM 52.8 SM 142 SF 568 SF 28% 68.0 SM 727 SF 4 desks

Shared Office - 2 persons Enclosed 10 5 6.6 SM 33.0 SM 71 SF 355 SF 28% 42.0 SM 455 SF 2 desks

Separate Communications Room Enclosed - 1 7.4 SM 7.4 SM 80 SF 80 SF 12% 8.0 SM 90 SF

NSE Total 26 93.2 SM 1,004 SF 118.0 SM 1,272 SF

5/12/2026 5 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

Bid Option Large Private Office Private 1 1 15.0 SM 15.0 SM 161 SF 161 SF 12% 17.0 SM 181 SF

Small Private Office Private 9 9 11.3 SM 101.7 SM 122 SF 1,095 SF 12% 114.0 SM 1,226 SF

Open Office Open 138 138 3.3 SM 455.4 SM 36 SF 4,902 SF 60% 729.0 SM 7,843 SF Workstations

Subtotal 572.1 SM 6,158 SF 860.0 SM 9,250 SF

Support Spaces

Conference Room (Medium) Enclosed - 2 64.8 SM 129.6 SM 698 SF 1,395 SF 28% 166.0 SM 1,786 SF

Storage Room Enclosed - 2 7.5 SM 15.0 SM 81 SF 161 SF 12% 17.0 SM 181 SF

Subtotal 144.6 SM 1,556 SF 183.0 SM 1,967 SF

Shared Spaces

Break Room Enclosed - 1 177.6 SM 177.6 SM 1,912 SF 1,912 SF 0% 178.0 SM 1,912 SF

DCOS Total 148 716.7 SM 7,714 SF 1,043.0 SM 11,217 SF

Shared Support Spaces Classroom Enclosed - 1 80.0 SM 80.0 SM 861 SF 861 SF 0% 80.0 SM 861 SF J5/J9, J7

Mailroom Enclosed - 1 20.0 SM 20.0 SM 215 SF 215 SF 0% 20.0 SM 215 SF J2, J3, J4, J6, J5/J9, J7

Break Room Enclosed - 1 582.0 SM 582.0 SM 6,265 SF 6,265 SF 0% 582.0 SM 6,265 SF DCOS, J2, J3, J4, J6, J5/J9 DCOS, J5/J9, J7, NCIA

Print Room Enclosed - 3 15.0 SM 45.0 SM 161 SF 484 SF 0% 45.0 SM 484 SF DCOS, J2, J3, J4, J6, J5/J9 DCOS, J5/J9, J7

Storage (Small) Enclosed - 2 7.5 SM 15.0 SM 81 SF 161 SF 0% 15.0 SM 161 SF

Breakout (Medium) Enclosed - 1 40.0 SM 40.0 SM 431 SF 431 SF 0% 40.0 SM 431 SF

Conference (Large) Enclosed - 1 102.7 SM 102.7 SM 1,105 SF 1,105 SF 0% 103.0 SM 1,105 SF J2, J3

Conference (Medium) Enclosed - 2 64.8 SM 129.5 SM 697 SF 1,394 SF 0% 130.0 SM 1,394 SF J4, J6, J7

Conference (Small) Enclosed - 4 41.5 SM 166.0 SM 447 SF 1,787 SF 0% 166.0 SM 1,787 SF DCOS, J2, J3, J5/J9 DCOS, J5/J9

Shared Support Total 0 1,180.2 SM 12,704 SF 1,181.0 SM 12,703 SF

485 4,616 SM 49,973 SF

633 5,659 SM 61,190 SF

Primary Building Entrance Support Vestibule Enclosed - 1 18.5 SM 18.5 SM 199 SF 199 SF 0% 19.0 SM 199 SF

Security Vestibule Enclosed - 1 9.5 SM 9.5 SM 102 SF 102 SF 0% 10.0 SM 102 SF

Security Office Enclosed 1 1 9.5 SM 9.5 SM 102 SF 102 SF 0% 10.0 SM 102 SF

Reception / Lobby Open - 1 130.0 SM 130.0 SM 1,399 SF 1,399 SF 0% 130.0 SM 1,399 SF

Wellness Room Enclosed - 3 7.5 SM 22.5 SM 81 SF 242 SF 0% 23.0 SM 242 SF

First Aid Room Enclosed - 1 7.5 SM 7.5 SM 81 SF 81 SF 0% 8.0 SM 81 SF

Primary Building Entrance Total 1 197.5 SM 2,126 SF 200.0 SM 2,125 SF

Total Mission Required Seats/Staff - w/ Bid Option Subtotal 1: Total Mission Programmed Area Requirements - w/

Bid Option (Net Assignable)

A d d e d

Total Mission Required Seats/Staff - Base Bid Subtotal 1: Total Mission Programmed Area Requirements -

Base Bid (Net Assignable)

5/12/2026 6 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

Restrooms / Janitors Closets Men's Restroom Enclosed - 2 35.0 SM 70.0 SM 377 SF 753 SF 0% 70.0 SM 753 SF 5 fixtures each (8 required total)

Women's Restroom Enclosed - 2 26.0 SM 52.0 SM 280 SF 560 SF 0% 52.0 SM 560 SF 4 fixtures each (4 required total)

Janitor's Closet Enclosed - 2 3.0 SM 6.0 SM 32 SF 65 SF 0% 6.0 SM 65 SF

Primary Building Entrance Total 0 128.0 SM 1,378 SF 128.0 SM 1,378 SF

Restrooms / Janitors Closets - w/ Bid Option Men's Restroom Enclosed - 1 35.0 SM 35.0 SM 377 SF 377 SF 0% 35.0 SM 377 SF 5 fixtures each

Women's Restroom Enclosed - 1 26.0 SM 26.0 SM 280 SF 280 SF 0% 26.0 SM 280 SF 4 fixtures each

Janitor's Closet Enclosed - 1 3.0 SM 3.0 SM 32 SF 32 SF 0% 3.0 SM 32 SF

Primary Building Entrance Total 0 64.0 SM 689 SF 64.0 SM 689 SF

1 328 SM 3,503 SF

1 392 SM 4,192 SF

486 4,944 SM 53,476 SF

634 6,051 SM 65,382 SF

Communications Telecom Rooms Enclosed - 4 15.0 SM 60.0 SM 161 SF 646 SF 0% 60.0 SM 646 SF 16' x 10'

Primary Building Entrance Total 0 60.0 SM 646 SF 60.0 SM 646 SF

Electrical / Fire Alarm Electrical Main Room Enclosed - 1 42.0 SM 42.0 SM 452 SF 452 SF 0% 42.0 SM 452 SF 15' x 30'

Electrical Room Enclosed - 5 10.0 SM 50.0 SM 108 SF 538 SF 0% 50.0 SM 538 SF 9' x 10'

Electrical Yard (Generator) External - 1 0.0 SM 0.0 SM 0 SF 0 SF 0% 0.0 SM 0 SF 20' x 30' External

Primary Building Entrance Total 0 92.0 SM 990 SF 92.0 SM 990 SF

Mechanical / Plumbing / Fire Supression Mechanical/ Plumbing Room Enclosed - 1 70.0 SM 70.0 SM 753 SF 753 SF 0% 70.0 SM 753 SF 20' x 30', 8' x 8', shafts

Fire Protection Room Enclosed - 1 21.0 SM 21.0 SM 226 SF 226 SF 0% 21.0 SM 226 SF 15' x 15'

Mechanical Yard External - 1 0.0 SM 0.0 SM 0 SF 0 SF 0% 0.0 SM 0 SF 30' x 40' External

Primary Building Entrance Total 0 91.0 SM 980 SF 91.0 SM 979 SF

5,187 SM 56,091 SF

6,294 SM 67,997 SF

Total Building Support and Amenity Seats/Staff - Base Bid Subtotal 2: Total Building Support and Amenity Programmed

Area - Base Bid

Total Programmed Seats/Staff - Base Bid Subtotal 3: Total Net Area Requirements - Base Bid (Subtotal 1

+ Subtotal 2)

Subtotal 4: Base Bid (Subtotal 3 + Comms + Elec/FA + Mech/Plumb/FX + Restrooms/Jan)

Subtotal 4: W/ Bid Option (Subtotal 3 + Comms + Elec/FA + Mech/Plumb/FX + Restrooms/Jan)

Total Programmed Seats/Staff - w/ Bid Option Subtotal 3: Total Net Area Requirements - w/ Bid Option

(Subtotal 1 + Subtotal 2)

Total Building Support and Amenity Seats/Staff - w/ Bid Option Subtotal 2: Total Building Support and Amenity Programmed

Area - w/ Bid Option

5/12/2026 7 of 8

Personnel/Space Description Space Type No. PN Space Qty NSM NSM Total NSF NSF Total Area Cir

Mult

NASM

Total

NASF

Subtotal Remarks

Estimate 24% 1,219 SM 13,181 SF

Estimate 8% 415 SM 4,487 SF

Estimate 5% 259 SM 2,805 SF

Estimate 70 SM 35 SM 377 SF

1,928 SM 20,850 SF

Estimate 24% 1,479 SM 15,979 SF

Estimate 8% 504 SM 5,440 SF

Estimate 5% 315 SM 3,400 SF

Estimate 70 SM 35 SM 377 SF

2,332 SM 25,196 SF

Grand Total Program Gross Area - Base Bid 7,115 SM 76,941 SF

Grand Total Program Gross Area - w/ Bid Option 8,626 SM 93,193 SF

Total - Base Bid

Primary Circulation

Building Envelope

Permanent Modular Construction Factor

Building Overhangs and Canopies (Calculated at 1/2 SF)

Primary Circulation

Building Envelope

Permanent Modular Construction Factor

Building Overhangs and Canopies (Calculated at 1/2 SF)

Total - W/ Bid Option

5/12/2026 8 of 8

SC49

SC49A

SC41

SC48

SC139

NH31J

SC51

SC140ASC43

SC142

SC39

SC34

SC44

SC47

SC37

SC35

SC33

SC45

SC32

SC52

SC42

SC139A

SC140

SC46

SC40

SC141

SC36

SC38

BLA

NDY ROAD

FO

RR

ES

TA

L D

RI

VE

BLA

NDY ROAD

FORRESTAL DRIVE

LEYTE AVENUE

CO

RR

EG

ID

OR

A

VE

NU

E

FECHTELER ROAD

FECHTELER ROAD

W

W W

W

W

W

W W

W W

W W

W W

W W

W W

W

W

W W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W W

W

W

W W

W W

W W

W

W

W

W

W

WW

W

W

W

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W

W

W W

W

W W

W W

W W

W

W W

W W

W

W

W

W W

W

W W

W

W

W W

W

W

W

W W

W W

W W

W

W W W W

W

W W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W W

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

SA

N

SA

N

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

G

G

G

G

G

G

G G

G

G

G

G

G

G G

G G

G

G

G G

G

G

G

G G

G G

G G

G

G

G

G G

G

G

G

G

G

G

G

G G

G G

G G

G G

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E E

E E

E

E E

E E

E

E E E E E

E E

E E

E

E

E

E

E

E E

E E

E E

E E

E E

E

E

E

E

E E E E E E E E E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

E E

E E

E E

E E

E

E

E E

E E

EEEE

E E E E E E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

E E

E E

E E

E

E

E

E

E

E

E

E

E

FI

LE

N

AM

E:

C

:\U se rs \c am pe ri\

DC

\A

CC

Do cs

\A

EC

O M

\B P-

AM

ER

(U S)

-6

0-

JF

C No rfo lk

M od ul ar

C am pu s

DB

R

FP

(N

AT

O

)\P ro je ct

F ile s\

De sig n

Co lla bo ra tio n\

-C

\N

AT

O _C

D1

.d wg

L

AY

O

UT

N

AM

E:

C

D1

P

LO

TT

ED

: W ed ne sd ay , M ay

6,

- 9 :4

4a m

U

SE

R:

C am pe rI

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

THIS DRAWING IS FOR REFERENCE ONLY, AND SHOWS THE DESIRED

FUNCTIONAL ARRANGEMENT AND ADJACEMCY FOR EACH DEPARTMENT. ITS

INCLUSION DOES NOT PRECLUDE THE D/B TEAM FROM ALTERING FOR

STRUCTURAL AND/OR MODULAR ACCOMODATIONS

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

LA

NT

N

AV

AL

S U

PP

O

R T

AC

TI

VI

TY

H

AM

PT

O

N R

O

AD

S

FY

S

PE

CI

AL

P

RO

JE

CT

J

FC

N

IN

TE

RI

M M

O

DU

LA

R

CA

M

PU

S

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

UP

PO

RT

A

CT

IV

IT

Y

HA

MP

TO

N

RO

AD

S M

ID

LA

N T

D C

C O

R E

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

SEAL

A/E INFO

DRAWFORM REVISION: 04 MAY 2023

SI

TE

D

EM

O

LI

TI

O

N

PL

AN

IPC IPC ACF

AS NOTED

CD101

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEYNOTES

A. THE ACTUAL FIELD CONDITIONS AT THE TIME OF CONSTRUCTION MAY

VARY FROM THAT PRESENTED ON THESE PLANS. CONFIRM THE

LOCATION OF ALL ITEMS PRIOR TO START OF CONSTRUCTION.

B. DEMOLITION OF PAVEMENTS INCLUDES AGGREGATE BASE COURSES.

C. PROVIDE SAW CUTS FOR ASPHALT AND CONCRETE DEMOLITION WORK

THAT IS ADJACENT TO EXISTING ASPHALT OR CONCRETE

PAVEMENT/WALKWAYS TO REMAIN.

12 8

1 REMOVE EXISTING CROSSWALK PAVEMENT MARKINGS.

2 DEMOLISH EXISTING CONCRETE WALK.

3 DEMOLISH EXISTING SITE STRUCTURE (GAZEBO).

4 DEMOLISH EXISTING BUILDING AND FOUNDATION.

5 DEMOLISH EXISTING ASPHALT PAVEMENT.

6 REMOVE EXISTING PAVEMENT MARKINGS.

7 DEMOLISH EXISTING GRAVEL PARKING AREA.

8 DEMOLISH EXISTING CONCRETE APRON.

9 DEMOLISH EXISTING WATER LINE.

10 DEMOLISH EXISTING GAS LINE.

11 DEMOLISH EXISTING SANITARY SEWER.

12 CAP OR PLUG EXISTING PIPE.

13 DEMOLISH ALL UTILITY SERVICES ASSOCIATED WITH EXISTING

STRUCTURES.

14 PROTECT EXISTING WATER LINE TO REMAIN DURING

CONSTRUCTION.

15 DEMOLISH EXISTING UNDERGROUND ELECTRICAL.

16 DEMOLISH EXISTING LIGHT.

17 CAP AND ABANDON EXISTING PIPING BELOW

ROADWAY.

NORTH

1"=40' 40' 20' 0 40' 80'

AM

EN

DM

EN

T

5/

CM

C

5/

/2

SC49

SC49A

SC41

SC48

SC139

NH31J

SC51

SC140ASC43

SC44

SC47

SC52

SC42

SC139A

SC140

SC46

SC40

BLA

NDY ROAD

FO

RR

ES

TA

L D

RI

VE

BLA

NDY ROAD

FORRESTAL DRIVE

LEYTE AVENUE

CO

RR

EG

ID

OR

A

VE

NU

E

FECHTELER ROAD

FECHTELER ROAD

X

X X

X

X

X

X

X X

X X

X X

X X

X

X

X X

X X

X

TEMPORARY PARKING GARAGE

(4 TIERS)

NATO JFCN INTERIM BUILDING

25'

20'

20'

R30'

R

R2 6'

R

'R20'R

R26'

R30'

R10'

20'

20'

10'

14'

98'

20'

FI

LE

N

AM

E:

C

:\U se rs \c am pe ri\

DC

\A

CC

Do cs

\A

EC

O M

\B P-

AM

ER

(U S)

-6

0-

JF

C No rfo lk

M od ul ar

C am pu s

DB

R

FP

(N

AT

O

)\P ro je ct

F ile s\

De sig n

Co lla bo ra tio n\

-C

\N

AT

O _C

S1

_C O

A2 .d wg L

AY

O

UT

N

AM

E:

C S1

P

LO

TT

ED

: W ed ne sd ay

, M ay

6,

- 9

:4 3a m U

SE

R:

C am pe rI

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

THIS DRAWING IS FOR REFERENCE ONLY, AND SHOWS THE DESIRED

FUNCTIONAL ARRANGEMENT AND ADJACEMCY FOR EACH DEPARTMENT. ITS

INCLUSION DOES NOT PRECLUDE THE D/B TEAM FROM ALTERING FOR

STRUCTURAL AND/OR MODULAR ACCOMODATIONS

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

LA

NT

N

AV

AL

S U

PP

O

R T

AC

TI

VI

TY

H

AM

PT

O

N R

O

AD

S

FY

S

PE

CI

AL

P

RO

JE

CT

J

FC

N

IN

TE

RI

M M

O

DU

LA

R

CA

M

PU

S

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

UP

PO

RT

A

CT

IV

IT

Y

HA

MP

TO

N

RO

AD

S M

ID

LA

N T

D C

C O

R E

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

SEAL

A/E INFO

DRAWFORM REVISION: 04 MAY 2023

SI

TE

P

LA

N

IPC IPC ACF

AS NOTED

CS101

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEYNOTES

A. GROUNDWATER MAY BE ENCOUNTERED FOR ALL EXCAVATIONS. PROVIDE

DEWATERING AS REQUIRED.

6 6

6 16

LEGEND

BUILDING FOOTPRINT

ASPHALT PAVEMENT

CONCRETE SIDEWALK

STORMWATER MANAGEMENT AREA

HEAVY DUTY CONCRETE

PAVEMENT

1 33-FT UNOBSTRUCTED SPACE SETBACK.

2 10-FT BUILDING SETBACK.

3 30-FT EXISTING BUILDING SETBACK.

4 100m (328-FT) NATO SETBACK FROM PERIMETER FENCE.

5 50-FT SETBACK FROM PERIMETER FENCE.

6 CONCRETE WALK. 8-FT MINIMUM WIDTH AT ENTRANCES AND

EXITS. 6-FT MINIMUM WIDTH ALL OTHERS. MATCH EXISTING

WALK WIDTH WHERE NEW CONCRETE IS PARALLEL WITH

EXISTING.

7 20-FT WIDE FIRE ACCESS ROAD (HEAVY DUTY CONCRETE

PAVEMENT).

8 ASPHALT PAVEMENT.

9 BUS PARKING.

10 AREA RESERVED FOR STORMWATER MANAGEMENT.

11 CHAINLINK FENCE.

12 DOUBLE LEAF SWING GATE WITH FIRE DEPARTMENT ACCESS

BOX.

13 PEDESTRIAN TURNSTILE WITH CAC CARD READER.

14 CROSSWALK PAVEMENT MARKING.

15 NO PARKING PAVEMENT MARKING FOR FIRE LANE.

16 ACCESSIBLE PARKING PAVEMENT MARKING AND SIGNAGE.

17 ENTRANCE CANOPY

NORTH

1"=40' 40' 20' 0 40' 80'

AM

EN

DM

EN

T

CM

C

5/

/2

X

X

X

X

X

X

X X

X

X X

X X

X

X

X X

X X

TEMPORARY PARKING GARAGE

(4 TIERS)

NATO JFCN INTERIM BUILDING

SC49

SC49A

SC138

SC41

SC48

SC139

SC138A

NH31J

SC50

SC51

SC140ASC43

SC53

NH31

SC44

SC47

SC52

SC42

SC139A

SC23

SC11

SC10

SC140

SC46

SC40

SC137

SC31

SC136

BLA

NDY ROAD

FO

RR

ES

TA

L D

RI

VE

BLA

NDY ROAD

FORRESTAL DRIVE

LEYTE AVENUE

CO

RR

EG

ID

OR

A

VE

NU

E

FECHTELER ROAD

FECHTELER ROAD

W

W

W

W

W

W

W W

W W

W W

W W

W W

W W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W W

W

W

W

W W W W

W W

W W

W W

W W

W W

W W

W

W

W

W W

W W

W

W W

W

W

W W

W

W W

W W

W

W

W W

W W

W W

W W

W W

W W

W

W W

W

W

W

W W W W W

W W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W W

W

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

CO

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S

S

SA

N

SA

N

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SA

N

SAN

SAN

SAN

SAN

SAN

SAN

SAN

G

G

G

G

G

G

G

G

G

G G

G G

G

G

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G G

G

E

E

E

E

E

E

E E

E E

E E

E

E E

E E

E

E

E E

E E

E E

E E

E E E E

E E

E E

E E

E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

E

E

E E E E E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E E

E E

E E

E

EE

E E

E E

E

E E

E E

E

E E

E

E

E

E E

E

E E

E E

E E

E E

E

E E

E E

E E

E

E

E E

E E

EEEE

E E

E E

E E E E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

E

E

E

E

E

E

E E

E E

E

E

E

EE

E E

E

E

E

E

E

E

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

W

W

W

PIV

PIV

C

C

C

UGC

C

U G

C

W

W W W

W W

C

W

GAS GAS GAS GAS

E

E

E

E E

E E

E E

E

E

E

E E

E E

E

E

E

E

EEEE

E

E

E

FI

LE

N

AM

E:

C

:\U se rs \c am pe ri\

DC

\A

CC

Do cs

\A

EC

O M

\B P-

AM

ER

(U S)

-6

0-

JF

C No rfo lk

M od ul ar

C am pu s

DB

R

FP

(N

AT

O

)\P ro je ct

F ile s\

De sig n

Co lla bo ra tio n\

-C

\N

AT

O _C

U1

_C O

A2 .d wg L

AY

O

UT

N

AM

E:

C U1

P

LO

TT

ED

: W ed ne sd ay

, M ay

6,

- 9

:4 2a m U

SE

R:

C am pe rI

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

P R

E L

IM

IN

A

R Y

THIS DRAWING IS FOR REFERENCE ONLY, AND SHOWS THE DESIRED

FUNCTIONAL ARRANGEMENT AND ADJACEMCY FOR EACH DEPARTMENT. ITS

INCLUSION DOES NOT PRECLUDE THE D/B TEAM FROM ALTERING FOR

STRUCTURAL AND/OR MODULAR ACCOMODATIONS

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

LA

NT

N

AV

AL

S U

PP

O

R T

AC

TI

VI

TY

H

AM

PT

O

N R

O

AD

S

FY

S

PE

CI

AL

P

RO

JE

CT

J

FC

N

IN

TE

RI

M M

O

DU

LA

R

CA

M

PU

S

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

UP

PO

RT

A

CT

IV

IT

Y

HA

MP

TO

N

RO

AD

S M

ID

LA

N T

D C

C O

R E

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

SEAL

A/E INFO

DRAWFORM REVISION: 04 MAY 2023

NORTH

SI

TE

U

TI

LI

TY

P

LA

N

IPC IPC ACF

AS NOTED

CU101

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEYNOTES

A. PROVIDE POST-INDICATOR VALVES FOR FIRE SERVICE CONNECTIONS.

B. PROVIDE ISOLATION GATE VALVES ON ALL BRANCH CONNECTIONS TO

NEW AND EXISTING WATER LINES.

C. PROVIDE SITE LIGHTING FOR NEW FACILITIES IN ACCORDANCE WITH THE

RFP DOCUMENTS.

D. FIELD VERIFY LOCATION OF EXISTING UTILITIES AND RELOCATE AS

NECESSARY WHERE IN CONFLICT WITH PROPOSED WORK.

E. GROUNDWATER MAY BE ENCOUNTERED FOR ALL EXCAVATIONS. PROVIDE

DEWATERING AS REQUIRED.

50' 25' 0 50' 100' 1"=50'

LEGEND

SANITARY SEWER

SANITARY SEWER MANHOLE

WATER MAIN

ISOLATION GATE VALVE

POST-INDICATOR VALVEPIV

TELECOMMUNICATION DUCTBANKUGC

C TELECOMMUNICATION MANHOLE

1 APPROXIMATE LOCATION OF EXISTING COMMUNICATION

MANHOLE.

2 3-WAY TELECOMM DUCTBANK.

3 6" FIRE WATER SERVICE.

4 POST-INDICATOR VALVE.

5 8" WATER MAIN.

6 2" DOMESTIC WATER SERVICE.

7 CONNECT TO EXISTING 8" WATER MAIN.

8 4" SANITARY SEWER LATERAL.

9 6" SANITARY SEWER.

10 CONNECT TO EXISTING SANITARY SEWER MANHOLE.

11 8" FIRE WATER SERVICE.

12 1.5" NATURAL GAS SERVICE.

13 CONNECT TO EXISTING NATURAL GAS.

14 PROVIDE GENERATOR.

15 PROVIDE MODULAR PAD-MOUNTED TRANSFORMER.

16 PROVIDE 35kV ELECTRICAL DUCTBANK.

17 CONNECT TO EXISTING 35kV ELECTRICAL DUCTBANK.

18 EXISTING 4-WAY SWITCH ELECTRICAL POINT OF CONNECTION

FOR BOTH FACILITIES.

SAN

W

FIRE HYDRANT

ELECTRICAL MANHOLE

E

NATURAL GASGAS

AM

EN

DM

EN

T

5/8 /20

CM

C 5/

/2

Continuation Cover Sheet
Space Program
Drawings

File details come from the government source that posted it. Updated .