THAN 1/2" & WIRE LARGER THAN #12 SHALL BE AS INDICATED.
MORE THAN TWO ARE PRESENT; ( ) INDICATES GROUND. CONDUIT LARGER
TICK MARKS, WHEN SHOWN, INDICATE NUMBER OF CONDUCTORS WHEN
INDICATE 2 #12 CONDUCTORS & 1 #12 GND. IN 1/2" CONDUIT UON.
BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICK MARKS
OR
OS
D
M
WP
GFI
LAF- 1,3
P
OS
P
3P
E
J
G
FMCP
EWC
3R
SPD
PP
TV
HH
EP
T
ANN
CONTROL WIRE FOR POWER PACK.
A1
EP401
METER AND METER BASE.
MOTOR RATED SWITCH/MANUAL MOTOR STARTER SWITCH
JUNCTION BOX AND COVER PLATE FOR SERVICE AS INDICATED.
INDICATES A CONDUIT RUN CONCEALED.
HOMERUNS TO PANEL. PANEL & CIRCUIT DESIGNATIONS AS INDICATED.
SPECIAL PURPOSE RECEPTACLE. 20A. 2 POLE, 3 WIRE, 250V. MOUNT
TWO DUPLEX CONVENIENCE RECEPTACLES, 20A, 125V. MOUNT 18" AFF, UON.
DUPLEX CONVENIENCE RECEPTACLE WITH INTERNAL GROUND FAULT
PROTECTION. 20A, 125V. MOUNT 18" AFF, UON.
BACKSPLASH OF COUNTER TOP WHERE COUNTER IS INDICATED.
RECEPTACLE AS NOTED ABOVE BUT, MOUNT 48" AFF OR 6" ABOVE
DUPLEX CONVENIENCE RECEPTACLE, 20A, 125V. MOUNT 18" AFF, UON.
18" AFF, UON. NEMA 4X.
WALL MOUNTED FIXTURE).
PHOTO-ELECTRIC SWITCH.
DIRECTION ( INDICATES BRACKET, WALL MOUNTED FIXTURE).
LED LIGHTING FIXTURE ( INDICATES BRACKET, WALL
EXIT LIGHTING FIXTURE. ARROW, WHEN USED, INDICATES
SINGLE POLE SWITCH, 20A, 120/277V. MOUNT 48" AFF, UON.
FILLED-IN QUADRANT(s) OF SYMBOL INDICATES NUMBER AND
ORIENTATION OF ILLUMINATED FACES.
MOUNTED FIXTURE).
DIMMER SWITCH, 0-10V, 120/277V. MOUNT 48" AFF, UON.
LED EMERGENCY LIGHTING FIXTURE ( INDICATES BRACKET,.
LEGEND AND ABBREVIATIONS
SURGE PROTECTION DEVICE.
PANELBOARD - 480Y/277V.
EMERGENCY POWER OFF (RED PUSH BUTTON). MOUNT 48" AFF, UON.
PANELBOARD - 208Y/120V.
WITH OVERLOADS. WHEN "WP" IS ALSO INDICATED, PROVIDE WITHIN A
DISCONNECT SWITCH PROVIDED INTEGRAL WITH EQUIPMENT.
HORSEPOWER
GROUND FAULT INTERRUPTER
GROUND
FUSED DISCONNECT SWITCH
FULL LOAD AMPS
FIRE ALARM CONTROL PANEL
CONTRACTOR INSTALLED
GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GOVERNMENT FURNISHED
EXISTING
TELECOMMUNICATIONS MAIN GROUND BUS BAR. SEE DETAIL SHEET T-501.
GROUND PER NATIONAL ELECTRICAL CODE.
GFCI
HP
GFI
GFGI
FLA
FACP
FDS
EXIST
INDICATES WEATHERPROOF EQUIPMENT
VOLTS ALTERNATING CURRENT
UNLESS OTHERWISE NOTED
TRANSFORMER
WATER HEATER
XFMR
WP
WH
W
VAC
WIRE
V
UON
VOLTS
TELEVISIONTV
TELEPHONE
SWITCH
SOLID NEUTRAL
TEL
SW
SN
CABLE TELEVISION
CIRCUIT BREAKER
EQUIPMENT
EMPTY CONDUIT
ELECTRICAL METALLIC TUBING
CLOSED CIRCUIT TELEVISION
DRAWING
CIRCUIT
CONDUIT
AMPERE TRIP
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPERE FRAME
AMERICAN WIRE GAUGE
BUILDING
BREAKER
AMPERE
EMT
EQUIP
EC
DWG
CKT
CCTV
BLDG
CATV
CB
C
BKR
AWG
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL (FMCP).
AT
AFG
AFF
AF
A
MAIN CIRCUIT BREAKERMCB
RIGID GALVANIZED STEEL
REQUIRED
RECEPTACLE
RGS
REQ'D
REC.
POLY VINYL CHLORIDE
PHASE
PVC
PH, ∅
P POLE
MTG HT
NORMALLY CLOSED
NON-FUSED
NORMALLY OPEN
NEUTRAL
NF
NEU, N
NO
NC
MOUNTED
MOUNTING HEIGHT
MAIN LUG ONLY
MOUNT
MTD
MT
MLO
THOUSAND CIRCULAR MILS
LIGHTING
KILOWATT HOUR
KILOVOLT AMPERE
LTG
KVA
KWH
KCMIL
REFER TO ARCHITECTURAL, MECHANICAL, AND PLUMBING PLANS FOR ADDITIONAL ABBREVIATIONS.
CTB COMMUNICATIONS
TERMINAL BACKBOARD
MAIN DISTRIBUTION PANELMDP
ELECTRIC WATER COOLER DUPLEX RECEPTACLE WITH INTERNAL GROUND FAULT
PROTECTION. 20A, 125V. COORDINATE EXACT MOUNTING LOCATION WITH THE
SURGE PROTECTION DEVICESPD
EQUIPMENT REQUIREMENTS.
TELECOMMUNICATIONS SERVER RACK.
CONSTRUCTION SHEET KEYNOTE DESIGNATION.
OCCUPANCY SENSOR WITH MANUAL ON/OFF OVERRIDE, 120/277V.
MOUNT 48" AFF, UON.
THREE-WAY SWITCH 20A, 120/277V. MOUNT 48" AFF, UON.
CALLOUT DESIGNATION
REFERENCED
SHEET NUMBER
ENLARGED REFERENCE
POWER PACK.
OCCUPANCY SENSOR CONTROLLER WITH A RADIAL COVERAGE OF 2000
SQUARE FEET WHEN MOUNTED AT 9FT. DUAL TECHNOLOGY, CEILING
MOUNTED.
DUPLEX RECEPTACLE TO SERVE TELEVISION, 20A, 125V. COORDINATE WITH
WALL CONSTRUCTION AND MOUNTING OF TV PRIOR TO INSTALLATION.
POLE MOUNTED LED SITE LIGHTING FIXTURE.
LED BOLLARD LIGHT FIXTURE.
CT CURRENT TRANSFORMER
HANDHOLE.
UNDERGROUND ELECTRICAL SECONDARY.
WEATHERPROOF (WHILE IN USE), WEATHER RESISTANT DUPLEX
CONVENIENCE RECEPTACLE WITH INTERNAL GROUND FAULT PROTECTION.
20A, 125V. MOUNT 18" AFF, UON.
EQUIPMENT GROUNDEG
GEC GROUNDING ELECTRODE
CONDUCTOR
ACTIVE VEHICLE BARRIERAVB
GND, G
NATIONAL ELECTRICAL CODENEC
FOUR-WAY SWITCH, 20A, 120/277V. MOUNT 48" AFF, UON.
GROUND ROD.
GROUND ROD TEST WELL.
UNDERGROUND ELECTRICAL PRIMARY.
EXISTING UNDERGROUND ELECTRICAL SECONDARY.
EXISTING UNDERGROUND ELECTRICAL PRIMARY.
EMERGENCY POWER PACK.
WALL MOUNTED THERMOSTAT SERVING IN-FLOOR HEATING SYSTEM.
DISCONNECT SWITCH. 3P = NO. OF POLES, 60 = SWITCH RATING, 40 =
FUSE RATING (NF INDICATES NON-FUSIBLE), 3R = NEMA RATING IF GIVEN.
EQUIPMENT CONNECTION AS NOTED. CONNECTION TAG INDICATES
EQUIPMENT LABEL AS IDENTIFIED ON OTHER TRADE'S DRAWINGS.
COMMUNICATIONS TERMINAL BACKBOARD. A/C PLYWOOD FIRE
RETARDANT TREATED MOUNTED WITH GRADE A SIDE EXPOSED.
MOUNT BOTTOM 8" AFF, UON. OVERALL LENGTH AS INDICATED ON
PLANS.
DEMOLITION SHEET KEYNOTE DESIGNATION.
REMOTE ANNUNICATOR FOR GENERATOR.
CAPACITY, RMS SYMMETRICAL
THOUSAND AMP INTERRUPTINGKAIC
UNIVERSALUNV
EMERGENCY FAST OPERATIONEFO
EXISTING COMPONENTS.
DEMOLISHED COMPONENTS.
NEW COMPONENTS.
AIR TERMINAL.
WEATHERPROOF ENCLOSURE.
US
UP
USE
UPE
TRN TRANSCEIVER.
LOWERCASE SUBSCRIPT WHEN SHOWN INDICATES CONTROLLABILITY OF
LIGHTING.
LIGHTNING PROTECTION CABLE CONNECTOR. ALL UNDER
GROUND CABLE CONNECTORS MUST BE EITHER EXOTHERMIC
WELD OR COMPRESSION TYPE.
Da
DAYLIGHTING OCCUPANCY SENSOR CONTROLLER WITH A RADIAL COVERAGE
OF 2000 SQUARE FEET WHEN MOUNTED AT 9FT. DUAL TECHNOLOGY, CEILING
MOUNTED.
PBB PRIMARY BONDING BUSBAR
DOS
DIMMING OCCUPANCY SENSOR WITH MANUAL ON/OFF OVERRIDE,
120/277V, 0-10V. MOUNT 48" AFF, UON.
EXISTING OVERHEAD ELECTRICAL.OHE
DRYER RECEPTACLE. 30A. 3-POLE, 4 WIRE, 250V. MOUNT 18" AFF, UON.
CO CARBON MONOXIDE SENSOR.
OS
D
GENERAL ELECTRICAL NOTE
ALL ELECTRICAL WORK AND MATERIAL IS NEW AND
PROVIDED BY THE CONTRACTOR, UNLESS INDICATED
OTHERWISE.
SW
DUPLEX CONVENIENCE RECEPTACLE, 20A, 125V. MOUNT 18" AFF, UON.
SUBSCRIPT 'SW' INDICATES SWITCHED RECEPTACLE. RECEPTACLE MUST BE
PERMANENTLY MARKED AND DENOTED AS 'CONTROLLED' PER NFPA 70.
A ATFP SHUTOFF SWITCH (BLUE PUSH BUTTON). MOUNT 48" AFF, UON.
HANDS-OFF-AUTOMATICHOA
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:3
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
E-001
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
LE
G
E N
D , N
O
TE
S , A
N D
A B
B R
E V
IA
T
IO
N
S
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E -0 q tu c k e r
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
315 358
12881097
RIDGE ROAD
FOG HARBOR ROAD
T
W
CP
C P
OHEOHEOHEOHEOHE
134135132
SAND/SALT
SHED
8 89
11 1
EXISTING
PROPANE TANK
GRAPHIC SCALE
1" = 50'-0"
30' 0 25' 50' 100' 150'
SITE PLAN - ELECTRICAL DEMOLITION
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
CU
TL
ER
, M
AI
NE
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
IM
P R
O V
E M
E N
TS
02/08/2023
CRH/LAF
EJA
DSN
1614700
N40085-19-D-9008 T008
JP HARVEY
ENGINEERING SOLUTIONS
JPHES.COM | 757.722.7074
29 KINGS WAY, HAMPTON, VA
JAS
03/09/2023
Approved By Jeffrey Hoyt, PWD ME, via Email
SI
TE
P
LA
N
EL
EC
TR
IC
A L
D
EM
O
LI
TI
O
N
WQT WQT HWB
ED101
1. EXISTING TO REMAIN.
2. DEMOLISH SERVICE DISCONNECT AND OVERHEAD
SERVICE CONDUCTORS TO BUILDING 130 BACK TO
POWER POLE.
3. DISCONNECT AND REMOVE PROPANE GENERATOR.
GENERATOR MUST BE TURNED OVER TO THE
GOVERNMENT. DEMOLISH GENERATOR PAD AND
PROPANE PIPING BACK TO PROPANE TANK.
4. DEMOLISH SERVICE DISCONNECT AND OVERHEAD
SERVICE CONDUCTORS TO BUILDING 129 BACK TO
POWER POLE.
5. DEMOLISH POLE-MOUNTED TRANSFORMERS AND
PRIMARY CONDUCTORS BACK TO TRANSMISSION
LINES.
6. DEMOLISH CONCRETE PAD FOR GENERATOR NEVER
INSTALLED. DEMOLISH CAPPED GAS PIPING BACK TO
POINT OF ORIGIN.
7. DEMOLISH GATE OPERATOR, CONDUCTORS AND
CONDUIT BACK TO PANELBOARD IN BUILDING 130.
8. DEMOLISH ALL GATE ACCESS CONTROLS AND
ASSOCIATED EQUIPMENT ON ISLAND BACK TO
BUILDING 130.
9. DEMOLISH ALL ELECTRICAL ITEMS FROM GUARD
BOOTH TO INCLUDE, BUT NOT LIMITED TO, LIGHTING,
RECEPTACLES, COMMUNICATIONS, CONDUIT, AND
CABLING BACK TO BUILDING 130.
10. DEMOLISH ACTIVE VEHICLE BARRIER CONTROL WIRING
AND POWER CONDUCTORS BACK TO BUILDING 130.
DEMOLISH UNDERGROUND CONDUIT WITHIN AREAS OF
SITE DEMOLITION SHOWN ON CIVIL DRAWINGS.
11. ACTIVE VEHICLE BARRIER SIGNAL LIGHT TO REMAIN.
CONDUIT AND CONDUCTORS MUST BE ABANDONED IN
PLACE.
12. ANTENNA TOWER TO REMAIN. DISCONNECT CABLING
AND DEMOLISH BACK TO BUILDING 130.
13. DEMOLITION TELECOMMUNICATIONS SERVICE TO
BUILDING 130 BACK TO NEAREST SPLICE CASE.
14. DEMOLITION TELECOMMUNICATIONS SERVICE TO
BUILDING 129 BACK TO NEAREST SPLICE CASE.
DEMOLITION KEYNOTESGENERAL NOTES
A. FOR ALL OTHER ELECTRICAL EXTERIOR ITEMS NOT
SHOWN ON THIS DRAWING, SEE CIVIL DRAWINGS FOR
MORE INFORMATION.
B. CONTRACTOR MUST FAMILIARIZE THEMSELVES WITH
EXISTING SITE CONDITIONS PRIOR TO ANY DEMOLITION.
DRAWINGS ARE BASED OFF OF LIMITED RECORD
DRAWINGS AND FIELD INVESTIGATION.
C. CONTRACTOR MUST REFER TO HAZMAT DRAWINGS
PRIOR TO ANY DEMOLITION.
D. SEE SHEETS ED102 AND ED103 FOR DEMOLITION INSIDE
OF BUILDINGS 129 AND 130.
E. CONTRACTOR MUST COORDINATE WITH GOVERNMENT
PRIOR TO DEMOLITION TO MAINTAIN CONNECTIVITY OF
TELECOMMUNICATIONS TO BUILDINGS NOT APART OF
THE DEMOLITION OF BUILDINGS 129 AND 130.
F. CONTRACTOR MUST COORDINATE WITH EMERA MAINE
POWER COMPANY PRIOR TO DISCONNECTION OF
TRANSFORMER FROM POWER TRANSMISSION LINES.
316 358
12881098
AutoCAD SHX Text
SCALE: 1"=50'-0"
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
MIDLANT DC CORE
AutoCAD SHX Text
NAVAL STATION-NORFOLK, VA.
AutoCAD SHX Text
AS NOTED
0' 1' 5' 10' 15'1'
1/4"=1'-0"
1 1
5 6
REMOVE EXISTING LIGHT FIXTURES, CONDUIT AND
CONDUCTORS BACK TO SOURCE.
REMOVE RECEPTACLES, CONDUIT AND CONDUCTORS
BACK TO SOURCE.
REMOVE ALL TELECOMMUNICATIONS OUTLETS AND
CABLES BACK TO SOURCE.
DISCONNECT AND REMOVE ALL SERVICE EQUIPMENT AND
ASSOCIATED WIRING BACK TO SOURCE.
CONDUITS MAY BE REUSED IF APPLICABLE.
NO CONDUIT SHALL BE ABANDONED UNLESS CONCEALED
IN WALLS AND/OR SLAB.
1.
2.
3.
4.
5.
6.
CONTRACTOR MUST FAMILIARIZE THEMSELVES WITH
EXISTING SITE CONDITIONS PRIOR TO ANY DEMOLITION.
DRAWINGS ARE BASED OFF OF LIMITED RECORD
DRAWINGS AND FIELD INVESTIGATION.
CONTRACTOR MUST REFER TO HAZMAT DRAWINGS PRIOR
TO ANY DEMOLITION.
SEE ELECTRICAL DEMOLITION SITE PLAN ON SHEET
ED101 FOR DEMOLITION OF UTILITIES.
SEE FIRE ALARM DRAWINGS FOR EQUIPMENT TO BE
DISCONNECTED, DEMOLISHED, AND/OR RELOCATED.
A.
B.
C.
D.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:5
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
ED102
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
V
IS
IT
O
R S
C E
N
TE
R F
LO
O
R P
LA
N
E
LE
C
T R
IC
A
L D
E M
O
LI
TI
O
N
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E D q tu c k e r
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
DEMOLITION KEYNOTES
SCALE: 1/4" = 1'-0"
VISITORS CENTER FLOOR PLAN - ELECTRICAL DEMOLITION
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
317 358
12881099
P
P FACP
1 1
EX. FACP
EX. 240/120V PANEL
EX. GATE
CONTROLS
EX. GATE
CONTROLS
EX. NACI RACKEX. FIBER ENCLOSURE
EX. POP UP
CONTROLS
FIRE ALARM
BATTERY
BOX
6 6
DISCONNECT AND REMOVE EXISTING EQUIPMENT IN SPACE
UON. DEMOLISH ALL RECEPTACLES, LIGHTING, SWITCHES,
CONDUIT AND CONDUCTORS BACK TO POINT OF SOURCE.
DISCONNECT AND REMOVE EXISTING RADIO
COMMUNICATIONS RACK FOR REUSE. RELOCATE
EQUIPMENT TO NEW INSPECTION STATION.
EXISTING FIRE ALARM KING-FISHER. SEE FIRE ALARM
DRAWINGS FOR MORE INFORMATION.
DISCONNECT AND REMOVE ALL RADIO ANTENNAS.
RELOCATE ALL ACTIVE ANTENNAS TO NEW INSPECTION
STATION.
DISCONNECT AND REMOVE EXISTING BADGING STATION
EQUIPMENT FOR REUSE. RELOCATE EQUIPMENT TO NEW
INSPECTION STATION.
REMOVE ALL TELECOMMUNICATIONS OUTLETS, CABLES
AND PATHWAYS BACK TO POINT OF SOURCE.
DISCONNECT AND REMOVE EXISTING ATS AND TURN OVER
TO GOVERNMENT.
DISCONNECT AND REMOVE EXISTING GENERATOR AND
TURN OVER TO GOVERNMENT.
1.
2.
3.
4.
5.
6.
7.
8.
0' 1' 5' 10' 15'1'
1/4"=1'-0"
CONTRACTOR MUST FAMILIARIZE THEMSELVES WITH
EXISTING SITE CONDITIONS PRIOR TO ANY DEMOLITION.
DRAWINGS ARE BASED OFF OF LIMITED RECORD
DRAWINGS AND FIELD INVESTIGATION.
CONTRACTOR MUST REFER TO HAZMAT DRAWINGS PRIOR
TO ANY DEMOLITION.
SEE ELECTRICAL DEMOLITION SITE PLAN ON SHEET
ED101 FOR DEMOLITION OF UTILITIES.
SEE FIRE ALARM DRAWINGS FOR EQUIPMENT TO BE
DISCONNECTED, DEMOLISHED, AND/OR RELOCATED.
A.
B.
C.
D.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:5
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
ED103
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
B U
IL
D
IN
G
E
LE
C
TR
IC
A L
D E
M O
LI
T
IO
N
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E D q tu c k e r
SCALE: 1/4" = 1'-0"
BUILDING 130 - ELECTRICAL DEMOLITION
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
DEMOLITION KEYNOTES
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
318 358
12881100
EE E
E
E E
E
RIDGE ROAD
T
RID
GE R
OAD
W
WV
W
W
W
DY
H
WVWSO
WSO
WSO
COMM COMM COMM COMM COMM
SAN
(PER GIS PLAN)
CO
M
M
CP
C P
EEEEEEEEEEEEEEEEEEEEEEEEEEEEE
1.8
1.7 1.5 1.1 0.8
1.4 1.3 1.0 0.8 0.6
1.4 1.4 1.3 1.1 0.9 0.7 0.6 0.5
1.4 1.4 1.4 1.3 1.2 1.0 0.9 0.7
1.3 1.4 1.5 1.5 1.4 1.3 1.2 1.1 0.9
1.3 1.5 1.7 1.7 1.6 1.5 1.4 1.3 1.2 1.1
1.4 1.7 2.0 2.2 2.1 1.9 1.7 1.5 1.3 1.3 1.3
1.4 1.9 2.4 2.7 2.7 2.3 1.9 1.6 1.4 1.4 1.6 1.9
2.5 2.0 1.6 1.5 1.5 1.7 2.2 2.7
1.3 1.4 1.7 2.1 2.7 2.9
1.4 1.8 2.3 2.6 2.5
1.4 1.8 2.1 2.1 1.8 1.4
1.4 1.7 1.7 1.6 1.5 1.4 1.2
1.5 1.5 1.5 1.6 1.6 1.6 1.4 1.3 1.2 1.0 0.8
1.5 1.6 1.8 2.0 2.2 2.1 1.9 1.6 1.2 0.9 0.7 0.5
1.9 2.4 2.7 2.8 2.5 2.0 1.4 0.9 0.6 0.5
1.3 0.9 0.8 0.7 0.7 0.7 0.9 1.2
1.3 1.0 0.8 0.8 0.8 0.8 1.0 1.3 1.7 2.2 2.6 2.6
1.2 1.0 0.9 0.8 0.8 0.9 1.0 1.2 1.5 1.8 2.0 2.1
1.0 0.9 0.8 0.8 0.8 0.9 1.0 1.1 1.3 1.4 1.5
0.9 0.8 0.8 0.8 0.8 0.9 1.0 1.1 1.2 1.3 1.4
0.8 0.8 0.8 0.8 0.8 0.9 1.0 1.1 1.2 1.3 1.4
0.7 0.8 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.3
0.7 0.9 1.0 1.2 1.2 1.3 1.3 1.3 1.2 1.2 1.3
0.8 1.0 1.3 1.5 1.7 1.7 1.7 1.5 1.3 1.2 1.3
0.8 1.1 1.6 2.0 2.3 2.3 2.1 1.7 1.4 1.3 1.3
0.8 1.1 1.7 2.3 2.7 2.7 2.3 1.7 1.2 1.1
3.3 2.6
2.7 2.3 1.7 1.4 1.2 1.1 1.2 1.5 2.1 2.5 2.7 2.4 1.9
2.1 1.8 1.5 1.3 1.2 1.2 1.2 1.5 1.8 2.1 2.2 2.0 1.7
1.6 1.4 1.3 1.2 1.1 1.1 1.2 1.3 1.5
1.3 1.2 1.1 1.1 1.1 1.1 1.1 1.1 1.2
1.2 1.1 1.1 1.1 1.1 1.1 1.0 1.0 1.0
1.4 1.3 1.2 1.2 1.2 1.1
1.6 1.5 1.4 1.3 1.2 1.0
1.9 1.8 1.7 1.5 1.2 1.0
2.3 2.3 2.1 1.8 1.4 1.0
2.6 2.8 2.6 2.1 1.5 1.0
2.4 2.6 2.4 1.9 1.3 0.8
2.0 1.9 2.0 2.4
3.6 2.8 2.3 2.1 2.1 2.5 3.1 3.3
2.8 3.0 2.8 2.4 1.9 1.6 1.5 1.5 1.6 1.6 1.5 1.5 1.5 1.7 2.1 2.6 2.9 2.9 2.7 2.8 3.3 3.8 3.9 3.6 3.0 2.4 2.2 2.1 2.3 2.6 2.8
2.3 2.5 2.4 2.1 1.9 1.8 1.8 2.0 2.2 2.2 2.1 1.8 1.7 1.8 2.0 2.3 2.5 2.6 2.7 2.8 3.0 3.3 3.4 3.2 2.7 2.3 2.0 1.9 2.0 2.1 2.1
1.7 1.8 1.8 1.8 1.8 1.8 2.1 2.5 2.9 3.0 2.6 2.2 1.9 1.7 1.8 1.9 2.0 2.1 2.4 2.5 2.6 2.8 2.8 2.7 2.4 2.1 1.9 1.7 1.7 1.7 1.6
1.2 1.2 1.3 1.5 1.6 1.8 2.2 2.9 3.5 3.6 3.0 2.3 1.9 1.6 1.5 1.5 1.5 1.7 2.0 2.1 2.3 2.4 2.4 2.3 2.1 2.0 1.8 1.6 1.5 1.5 1.3
1.3 1.6 1.8 2.1 2.2 2.2 2.2 2.0 1.9 1.8 1.7 1.6 1.4 1.3
1.5 1.9 2.1 2.2 2.2 2.1 2.0 1.9 1.8 1.7 1.6 1.5
1.7 2.1 2.5 2.5 2.4 2.1 1.9 1.8 1.7 1.7 1.7
2.4 2.9 3.0 2.7 2.2 1.9 1.7 1.7 1.8 1.9
3.6 3.4 2.9 2.3 1.8 1.7 1.7 1.9 2.2
3.6 2.7 2.1 1.7 1.6 1.6 1.9 2.4
1.4 1.3 1.4 1.6 2.1
0.6 0.9 1.2 1.4
0.5 0.8 1.1 1.4 1.7 1.8
0.4 0.8 1.1 1.6 2.0 2.3
0.4 0.8 1.1 1.7 2.3 2.7
0.4 0.7 1.1 1.6 2.3 2.8
0.4 0.7 1.1 1.5 2.1 2.4
0.4 0.7 1.0 1.3 1.6 1.7
0.8 1.0
1.4 1.9 2.4
1.3 1.3 1.5 1.7 2.1
2.3 1.8 1.6 1.4 1.4 1.5 1.6
3.0 2.5 2.0 1.6 1.4 1.3 1.2 1.1
3.0 2.4 1.9 1.5
2.7 2.5 2.0 1.6
2.3 2.1 1.8
1.8 2.0 2.0
1.8 2.1 2.1
1.8 2.3
1.9 2.5
2.0 2.7
1.4 1.9 2.4 2.5
1.5 1.8 1.7
G
H
G
G
GG
G G
G
GG
G
G H
H H
ROADWAY TO
INTERSECTION
RESPONSE ZONE
ACCESS CONTROL ZONE -
BEHIND BUILDING
ACCESS CONTROL ZONE -
FRONT OF BUILDING
APPROACH ZONE
PARKING LOT
DESCRIPTION
LIGHTING STATISTICS SCHEDULE
AVG MAX MIN AVG/MIN MAX/MIN
APPROACH ZONE
RESPONSE ZONE
PARKING LOT
ROADWAY TO INTERSECTION
1.56
1.24
1.57
2.16
1.29
1.91
2.9
2.7
3.3
3.9
2.8
3.0
0.5
0.7
0.8
1.2
0.4
1.1
3.12
1.77
1.96
1.80
3.23
1.74
5.80
3.86
4.13
3.25
7.00
2.73
ACCESS CONTROL ZONE -
FRONT OF BUILDING
ACCESS CONTROL ZONE -
BEHIND BUILDING
GRAPHIC SCALE
1" = 50'-0"
30' 0 25' 50' 100' 150'
SITE PLAN - ELECTRICAL LIGHTING
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
CU
TL
ER
, M
AI
NE
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
IM
P R
O V
E M
E N
TS
02/08/2023
CRH/LAF
EJA
DSN
1614700
N40085-19-D-9008 T008
JP HARVEY
ENGINEERING SOLUTIONS
JPHES.COM | 757.722.7074
29 KINGS WAY, HAMPTON, VA
JAS
03/09/2023
Approved By Jeffrey Hoyt, PWD ME, via Email
WQT WQT HWB
ES101
GENERAL NOTES
A. SEE LIGHTING FIXTURE SCHEDULE AND DETAILS ON
SHEETS EL501 AND EL503.
319 358
12881101
AutoCAD SHX Text
SCALE: 1"=50'-0"
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
MIDLANT DC CORE
AutoCAD SHX Text
NAVAL STATION-NORFOLK, VA.
AutoCAD SHX Text
SITE PLAN - ELECTRICAL LIGHTING
RIDGE ROAD
T
RID
GE R
OAD
W
W
W
DY
H
CP
C P
225kVA XFMR
'ATS'
PANEL 'MDP'
PANEL 'G'
OHEOHEOHEOHEOHE
PANEL 'L4'
EXISTING
POWER POLE
UP
VISITORS CONTROL CENTER
US
US
US
US
US150kW DIESEL
GENERATOR
G
H
G
GG
G
G
G
GG
G
G H
H
H
G-2
"B"
"A"
"A" "A""B"
"B" "B"
"B"
"A""A" "A"
"B" "B" "A"
8 TYPICAL
8 TYPICAL
9 TYPICAL
9 TYPICAL
G "B"
US
US
"A"
INSPECTION STATION, POV, AND
CVIS BUILDING
PANEL 'L5'
7 10
SLIDING GATE
OPERATOR #3
SLIDING GATE
OPERATOR #2
E L4-1
CANOPY
DROP ARM #1
CANOPY
DROP ARM #2
CANOPY
DROP ARM #3AVB CONTROLLER #2
SEWAGE GRINDER PUMP 12
US
USUS
SLIDING GATE
OPERATOR #1 13
AVB CONTROLLER #1 US US
FIRE STORAGE
TANKS ALARM
SYSTEM
E L2-13
X X
X
X
X
X
X
X
POWER CENTER
U S
US US
US
U S
US
US USUS
FLASHING RED
TRAFFIC SIGNAL
SERVICE
DISCONNECT
CONCRETE-EMBEDDED
SNOW MELT SYSTEM
CONCRETE-EMBEDDED
SNOW MELT SYSTEM 20
USPANEL 'PS'
XFMR 'T3'
GRAPHIC SCALE
1" = 50'-0"
30' 0 25' 50' 100' 150'
SITE PLAN - ELECTRICAL POWER D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
CU
TL
ER
, M
AI
NE
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
IM
P R
O V
E M
E N
TS
02/08/2023
CRH/LAF
EJA
DSN
1614700
N40085-19-D-9008 T008
JP HARVEY
ENGINEERING SOLUTIONS
JPHES.COM | 757.722.7074
29 KINGS WAY, HAMPTON, VA
JAS
03/09/2023
Approved By Jeffrey Hoyt, PWD ME, via Email
WQT WQT HWB
ES102
1. PROVIDE A 2-WAY CONCERE-ENCASED 4" CONDUIT
DUCTBANK FROM SERVICE TRANSFORMER TO SERVICE
DISCONNECT. ONE CONDUIT MUST BE USED FOR
SERVICE CONDUCTORS AND THE OTHER MUST BE A
SPARE.
2. PROVIDE A 225kVA TRANSFORMER AND PAD. SEE
SHEETS EP501 AND EP701 FOR MORE INFORMATION.
3. PROVIDE A 5" CONDUIT WITH 25kV CLASS, 3-1/C #1/0
COPPER EPR 133% INSULATION PRIMARY CONDUCTORS
FROM POWER POLE TO SERVICE TRANSFORMER.
4. PROVIDE A CONCRETE-ENCASED 2-WAY 4" CONDUIT
DUCTBANK FROM GENERATOR TO 'ATS'. ONE CONDUIT
MUST BE USED FOR FEEDERS AND THE OTHER MUST
BE A SPARE.
5. PROVIDE A 2-WAY 2-1/2" CONDUIT DUCTBANK FROM
PANEL MDP TO PANEL G.
6. PROVIDE A 150kW, 480Y/277V, 3Ø, 4-WIRE GENERATOR
WITHIN A LEVEL 2 SOUND ATTENUATED ENCLOSURE
AND WITH A 3-DAY RATED AT FULL LOAD SUB-BASE
TANK. ENCLOSURE MUST BE RATED NEMA 4X,
STAINLESS STEEL.
7. PROVIDE (2) 1-1/2" CONDUITS FROM PANEL 'L4' TO
ACTIVE DROP ARM BEAM CONTROLLER. PROVIDE ONE
CONDUIT WITH 4#2 AND 1#6 GROUND AND THE OTHER
CONDUIT MUST BE FOR CONTROLS. SEE SHEET EP602
FOR PANELBOARD CIRCUIT NUMBER. SEE SHEET TY503
FOR DROP ARM TYPE BARRIER DETAIL INFORMATION.
8. PROVIDE 3#8 AND 1#8 GROUND IN 3/4" CONDUIT.
9. PROVIDE 2#10 AND 1#10 GROUND UP POLE TO LIGHT
FIXTURE. TAP PHASE AS INDICATED.
10. PROVIDE A 3/4" CONDUIT WITH 4#10 AND 1#10 GROUND
FROM PANEL 'L5' TO CANOPY DROP ARM BEAM
CONTROLLER. SHEET SHEET EP602 FOR PANELBOARD
CIRCUIT NUMBER.
11. PROVIDE A 6-WAY 1-1/2" DUCTBANK FROM PANEL G TO
AREA OF GATE OPERATORS AND POWER CENTER. ONE
CONDUIT MUST BE USED FOR GATE OPERATOR
CONDUCTORS, ONE CONDUIT FOR POWER CENTER
MOUNTED ON STRUT SUPPORT SYSTEM, THREE FOR
CONTROLS AND DATA CABLING, AND ONE FOR SNOW
MELT SYSTEM. ROUTE CONTROL/DATA CONDUITS TO
INSPECTION BUILDING TELECOM ROOM.
12. SEWAGE GRINDER PUMP SYSTEM, 240V, 1Ø WITH
NEUTRAL. PROVIDE A 208V-240/120V, 5kVA BOOST
TRANSFORMER AND A 30A, 2-POLE, NEMA 3R
DISCONNECT FUSED AT 30A ON THE PRIMARY SIDE OF
TRANSFORMER. PROVIDE 3#10 AND 1#10 GROUND IN 1"
CONDUIT BACK TO PANEL L4. SEE SHEET EP602 FOR
CIRCUIT INFORMATION.
13. GATE OPERATOR, 1HP, 460V, 1ø. PROVIDE 2#8 AND 1#8
GROUND. SEE MANUFACTURER'S WIRING DIAGRAMS
FOR CONNECTING GATE OPERATOR AND CONTROLS.
SEE PANELBOARD SCHEDULES FOR CIRCUIT
INFORMATION. SEE SHEET TS102 FOR MORE
INFORMATION ON OUTBOUND LANE OPERATION AT
RESTRICTED AREA FENCE.
14. PROVIDE A 24"X36"X24" NON-TRAFFIC RATED
HANDHOLE. SEE DETAIL ON SHEET EP501.
15. PROVIDE A 12"X18"X12" NON-TRAFFIC RATED
HANDHOLE. SEE DETAIL ON SHEET EP501.
16. PROVIDE A 4-WAY 1-1/2" DUCTBANK FROM PANEL G TO
GATE OPERATOR AND SNOW MELT SYSTEM. ONE
CONDUIT MUST BE USED FOR GATE OPERATOR
CONDUCTORS, ONE FOR CONTROLS AND DATA
CABLING FOR GATE OPERATOR, AND TWO FOR THE
CONCRETE-EMBEDDED SNOW MELT CABLING.
17. PROVIDE A STRUT SUPPORT SYSTEM FOR ACTIVE
VEHICLE BARRIER (AVB) CONTROLS, INTERCOM,
STEP-DOWN TRANSFORMER, POWER RECEPTACLE,
AND FLASHING TRAFFIC SIGNAL AT INTERSECTION.
PROVIDE A 7.5kVA, 480V-240/120V, 1ø TRANSFORMER
WITH INTEGRAL POWER CENTER CONSISTING OF A
MINIMUM OF 5 SPACES. PROVIDE A 30A-2P PRIMARY
CIRCUIT BREAKER AND A 40A-2P SECONDARY CIRCUIT
BREAKER IN POWER CENTER. PROVIDE A 20A-1P
CIRCUIT BREAKER FOR RECEPTACLE AND A 20A-1P
CIRCUIT BREAKER FOR TRAFFIC SIGNAL. PROVIDE A
RECEPTACLE WITH INTEGRAL GROUND FAULT
PROTECTION AND PROVIDE IN A WEATHERPROOF
WHILE IN USE ENCLOSURE. MOUNT ALL EQUIPMENT TO
STRUCTURE. SEE SHEET TS102 FOR MORE
INFORMATION ON AVB CONTROLS AND INTERCOM
EQUIPMENT.
18. PROVIDE A 1-1/2" CONDUIT FROM STRUT SUPPORT
SYSTEM TO HANDHOLE FOR POWER CONDUCTORS.
PROVIDE 2#8 AND 1#8 GROUND AND ROUTE FROM
POWER CENTER BACK TO PANEL G IN INSPECTION
STATION BUILDING.
19. PROVIDE 2#10 AND 1#10 GROUND IN 3/4" CONDUIT.
20. PROVIDE A 480V, 3ø SNOW MELT SYSTEM EMBEDDED IN
CONCRETE TO COVER INDICATED AREA. SYSTEM MUST
BE AUTOMATIC CONTROLLED WITH PRESET
TEMPERATURE INPUTS, BUT MUST ALSO HAVE A MEANS
OF MANUAL OVERRIDE.
21. PROVIDE A 2" CONDUIT FROM PANEL 'MDP' TO XFMR 'T3'
IN WELL PUMP HOUSE. SEE SHEET EP701 FOR MORE
INFORMATION.
SHEET KEYNOTESGENERAL NOTES
A. SEE POWER RISER DIAGRAM ON SHEET EP701 FOR
MORE INFORMATION ON CONDUCTOR SIZES INSTALLED
IN CONDUITS AND ROUTING OF CONDUIT INTO
FACILITIES.
B. SEE LIGHTING FIXTURE SCHEDULE AND DETAILS ON
SHEETS EL501 & EL503 AND SEE POWER DETAILS ON
SHEETS EP501 & EP502 FOR MORE INFORMATION.
C. ALL EMPTY CONDUITS MUST BE PROVIDED WITH
PULLSTRING.
D. ALL CABLING INSTALLED WITHIN POWER RACEWAYS
AND WITHIN HANDHOLES MUST BE TYPE THHN WITH 600
VOLT RATED INSULATION. ALL SPLICES MADE WITHIN
HANDHOLES MUST BE MADE WITH WATERPROOF
POLARIS CONNECTORS.
E. FOR ALL OTHER ELECTRICAL EXTERIOR ITEMS NOT
SHOWN ON THIS DRAWING, SEE CIVIL DRAWINGS FOR
MORE INFORMATION.
F. LETTERS IN QUOTATIONS BESIDE SITE LIGHTING
FIXTURES INDICATE PHASE TO BE CONNECTED TO.
· "A" = PHASE A
· "B" = PHASE B
G. CONTRACTOR MUST COORDINATE WITH EMERA MAINE
POWER COMPANY PRIOR TO CONNECTING TO POWER
TRANSMISSION LINES.
H. SEE CIVL SHEETS FOR MORE INFORMATION ON SAFETY
SIGNAGE FOR THE AVBs AND DROP ARMS AROUND THE
INSPECTION STATION.
320 358
12881102
AutoCAD SHX Text
SCALE: 1"=50'-0"
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
MIDLANT DC CORE
AutoCAD SHX Text
NAVAL STATION-NORFOLK, VA.
AutoCAD SHX Text
SITE PLAN - ELECTRICAL POWER
R
F
DOS
DOSDOSOS
D D
DOS
DOS DOS OS
O S
OS
OS
OS
OS
OS OS
EP PPOS EP
PP
EP PP
OS
PP
PP OS
OS
PP
D D
D
D
D
EPPP
OS
MECH/ELEC
VESTIBULE
TOILET
MUD ROOM
COMM
116LOCKER ROOM
OFFICE
INTERVIEW
OFFICE
DAYROOM
SHOWER
HALLWAY
SIPRNET
EXIST
BREAKROOM
A1
TYPICALB2
HALLWAY
PANEL 'MDP'
PANEL 'TPP1'
F
'ATS'
X
A1
A1
A1 A1
B2A1A1
A1
A1
A1
A1
A1MOTHER'S
TOILET
WAITING
ID/CHECK-IN
ADMIN/COPY
HALLWAY
HALLWAY
D
D
MDP-1
MDP-3
MDP-5
F
JANITOR
PANEL 'L1' PANEL 'L2'
K
D
A1
A1
SERVICE
DISCONNECT
D D
0' 1' 5' 10' 15'1'
1/4"=1'-0"
SEE SHEETS EL501-EL503 FOR LIGHT FIXTURE SCHEDULE
AND DETAILS.
A.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:1
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
EL101
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
V
IS
IT
O
R C
O N
T R
O L
C E
N
TE
R F
LO
O
R P
LA
N
E
LE
C
TR
IC
A L
LI
G
H T
IN
G
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E L q tu c k e r
SCALE: 1/4" = 1'-0"
VISITOR CONTROL CENTER FLOOR PLAN - ELECTRICAL LIGHTING
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
321 358
12881103
O S
D
O S
O S
O S
P
H O
A
D
OS
OS
OS
OS
PP
EP
PP
EP
OS
STOR/JAN
CORR
BREAKROOM
WAITING
INSPECTION
OFFICE
RFI/SECURE
ROOM
RESTROOM
PANEL 'G'
F
J
TYPICAL
B2
A1
A1
A1
A1
B2
B2
J
A1
A1
B2
D
G-1
G-3
G-7
ROOF OUTLINE (TYPICAL)
ROOF OUTLINE (TYPICAL)
B D EC
STORAGE
COMM
G-3
G-5
A
G-11
3/16" = 1'-0"
0'5' 5' 10'
PROVIDE A 6 POLE, 2-CIRCUIT HOA SWITCH.
CONNECT EMERGENCY LIGHTING CIRCUIT BETWEEN HOA
SWITCH AND LIGHTING INVERTER.
CONNECT PHOTOCELL TO HOA SWITCH FOR AUTOMATIC
CONTROL OF CANOPY LIGHTING.
PROVIDE (2) 400 WATT LIGHTING INVERTERS STACKED ON
WALL WITH AN INPUT VOLTAGE OF 277V AND AN OUTPUT
VOLTAGE OF 277V.
1.
2.
3.
4.
SEE SHEETS EL501-EL503 FOR LIGHT FIXTURE SCHEDULE
AND DETAILS.
A.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:3
:4
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \I n s p e c ti o n S ta ti o n
W
P
C u tl e r_
IS
E L
E C
R
.r v t
EL102
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
IN
S
P E
C T
IO
N
S
TA
T
IO
N , P
O V
, A N
D C
V
IS
C A
N O
P
IE
S F
LO
O
R P
LA
N
E
LE
C
T R
IC
A
L
LI
G
H T
IN
G
HWBWCJ WCJ
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D C
C O
R E
E L s fe a g in s
SCALE: 3/16" = 1'-0"
INSPECTION STATION, POV, AND CVIS CANOPIES FLOOR PLAN - ELECTRICAL
LIGHTING
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
SHEET KEYNOTES
PLAN
NORTH
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
322 358
12881104
DIRECT/INDIRECT LED TROFFER
REVISED: APRIL 2016 NL-1LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH ONE-PIECE LOWER REFLECTOR
HAVING TEXTURED, HIGH REFLECTANCE, WHITE POLYESTER POWDER-COATED
FINISH. OPTIONAL SIZES OF 1FT x 4FT, 2FT x 2FT, AND 2FT x 4FT AVAILABLE.
2. LIGHT SOURCE - UPWARD-FACING LEDS WITH DIFFUSE LENS TO ELIMINATE DIRECT
VIEW OF LIGHT SOURCE. 4000K COLOR TEMPERATURE UON, MAXIMUM BINNING
TOLERANCE OF A 4-STEP MCADAM ELLIPSE, MINIMUM EFFICACY OF 90 LUMENS/WATT,
WITH A MINIMUM CRI OF 80. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE
SCHEDULE.
3. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL
HARMONIC DISTORTION. STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN
LUMINAIRE SCHEDULE.
4. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN
EQUIPPED WITH EMERGENCY BATTERY BACK-UP. IC RATED WHEN INDICATED.
5. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
6. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER
OR PREFERENCE.
LED LINEAR RECESSED STRIP
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM FRAME AND HEAT SINK WITH SILVER OR WHITE
ENAMELED FINISH. APPROXIMATELY 4IN X 4FT AND 4IN X 8 FT.
2. LENS - IMPACT-RESISTANT ACRYLIC.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 75
LUMENS/WATT. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REMOTELY-LOCATED ABOUT CEILING, REPLACEABLE, HIGH-EFFICIENCY
DRIVER WITH MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V, THERMAL
MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION. ON-OFF CONTROL,
STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES WITH
LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - SUSPENDED FROM HARD OR ACOUSTICAL TILE CEILING.
7. OPTIONS - 0-10V OR DALI SYSTEM DIMMING.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LED INDUSTRIAL STRIP
REVISED: APRIL 2016 NL-7LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR
RIGIDITY AND SPECULAR ALUMINUM OR HIGHLY-REFLECTIVE PAINTED STEEL
REFLECTORS. OPTIONAL LENGTHS OF 4FT OR 8FT.
2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH
HIGH-REFLECTANCE, WHITE POLYESTER POWDER COAT, PAINTED AFTER
FABRICATION.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 100
LUMENS/WATT. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL
HARMONIC DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE
AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN
EQUIPPED WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE ON CEILING OR SUSPENDED.
7. OPTIONS - WIRE GUARD, CHAIN, STEM OR SWIVEL STEM HANGERS.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LED RECESSED DOWNLIGHT
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, OR FORGED ALUMINUM WITH HEAT
SINK. DRIVER MUST BE ACCESSIBLE FROM BOTTOM OF LUMINAIRE. PROVIDE T-BAR
HANGERS FOR INSTALLATION IN ACOUSTICAL TILE CEILINGS OR TABS WHEN
MOUNTING IN HARD CEILINGS. SQUARE DOWNLIGHT. SIZE OF 4IN AVAILABLE.
2. REFLECTOR AND TRIM - SPECIFICATION GRADE, LOW IRRIDESCENT, SPECULAR
ALUMINUM REFLECTOR WITH METALLIC OR PAINTED TRIM RING.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 90
LUMENS/WATT. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL
HARMONIC DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE
AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN
EQUIPPED WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - RECESSED IN HARD OR ACOUSTICAL TILE CEILING.
7. OPTIONS - EMERGENCY BATTERY BACK-UP, WALL-WASH TRIM, IC RATED FOR DIRECT
CONTACT WITH INSULATION, VARIOUS APERTURE DIAMETERS, AND VARIOUS GLASS
LENSES.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LED WALL PACK
LUMINAIRE REQUIREMENTS:
1.
2.
3.
4.
5.
6.
7.
HOUSING - DIE-CAST OR EXTRUDED ALUMINUM WITH INTEGRAL PASSIVE
COOLING MECHANISM. HEAT SINK SHALL BE INCORPORATED DIRECTLY
INTO HOUSING OR DRIVER COMPARTMENT TO ENSURE MAXIMUM HEAT
TRANSFER AND DISSIPATION.
FINISH - MULTI-STAGE PRE-TREATMENT, FINISHED WITH BAKED-ON
POLYESTER POWDER COAT. FINISH SHALL PASS 2500 HOUR SALT SPRAY
TEST PER ASTM B117. STANDARD FINISH IS DARK BRONZE, WITH OTHER
CUSTOM COLORS AVAILABLE.
POWER SUPPLY/LED DIMMABLE DRIVER - CLASS 1 DRIVER SHALL OPERATE
AT 120/277 VOLTS, 50/60 HZ, WITH OTHER VOLTAGE OPTIONAL; POWER
FACTOR GREATER THAN 0.9 AND THD LESS THAN 20% AT FULL LOAD.
MINIMUM EFFICACY SHALL BE 60 LUMENS/WATT AT MAXIMUM 600mA
OPERATING CURRENT. 0-10V DIMMING CAPABILITIES.
LED OPTICAL ASSEMBLY - PRECISION MOLDED ACRYLIC LENS PROVIDED
FOR MULTIPLE HIGH-POWERED LEDS PRODUCING NEMA TYPE III
DISTRIBUTION OR AS OTHERWISE NOTED. BUG UPLIGHT RATING OF U0,
WITH GLARE RATING AS DETERMINED BY LIGHTING ZONE INSTALLED.
MINIMUM COLOR RENDERING INDEX (CRI) SHALL BE 70 FOR CORRELATED
COLOR TEMPERATURE (CCT) OF 4000-4500 DEGREES K.
CERTIFICATION - UL AND/OR ETL LISTED FOR DAMP OR WET LOCATION AS
INDICATED, AND RoHS COMPLIANT.
OPTIONS - VARIOUS LUMEN OUTPUT RATING AS INDICATED, PHOTOCELL.
THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A
LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT
INTENDED TO INDICATE A CERTAIN MANUFACTURER OR
PREFERENCE.
REVISED: MARCH 2013 XL-17LIGHTING PLATE:
A1 B2
C1 C2 D
F
A1
LIGHT FIXTURE SCHEDULE
WATTAGEMOUNTING NOTESFIXTURE TYPETYPE
MARK
16RECESSEDLED
LIGHT SOURCE LUMENS
2,000
VOLTAGE
UNV
B2
2'X2' INDIRECT/DIRECT LED TROFFER
4' LINEAR INDUSTRIAL LED STRIP LED UNV PENDENT/SURFACE 20 3,000
1, 2
D 4" LED DOWNLIGHT LED UNV RECESSED 1,50018 2, 3
4, 5, 7F LED WALL PACK LED UNV WALL 26 2,300
1) 2) 3) 4) 5) 6) 7) 8)
PROVIDE EMERGENCY BATTERY PACK/DRIVER WHERE HALF SHADED LIGHTING FITURES ARE SHOWN.
PROVIDE 0-10V DIMMING CONTROL WIRE AS REQUIRED PER ROOM/SPACE.
PROVIDE A WET RATED FIXTURE.
PROVIDE FIXTURE WITH INTEGRAL EMERGENCY BATTERY PACK/DRIVER.
PROVIDE FIXTURE WITH INTEGRAL PHOTOCELL.
POLE MOUNTING HEIGHT SHALL BE 25'-0".
PROVIDE FIXTURE WITH DIMMABLE DUSK TO DAWN LED DRIVER.
PROVIDE FIXTURE AS A DARK SKY COMPLIANT FIXTURE.
NOTES:
-N/A1SURFACE/WALLUNVLEDLED EXIT SIGNX
3, 5, 6, 7, 8G LED POLE MOUNT LED UNV POLE 89 12,160
H LED POLE MOUNT LED UNV POLE 14,351101 3, 5, 6, 7, 8
J LED CANOPY LIGHT LED UNV RECESSED 12,917127 -
K 4' LED WALL WASH LED UNV WALL 3,80040 2
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:2
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
EL501
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
LI
G
H
TI
N G
F
IX
T U
R E
S C
H E
D U
LE
A
N D
D E
TA
IL
S
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E L q tu c k e r
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
323 358
12881105
13"
NOMINAL
NOMINAL
9"
1.
2.
3.
4.
5.
6.
7.
8.
HOUSING - DIE-CAST ALUMINUM OR HIGH-IMPACT, UV-STABILIZED, INJECTION-
MOLDED THERMOPLASTIC. SINGLE OR DOUBLE-FACED AS INDICATED.
FINISH (ON CAST ALUMINUM HOUSING ONLY) - TEXTURED POWDER COAT
FINISH OPTIONS INCLUDE WHITE, WHITE WITH BRUSHED ALUMINUM FACE,
BLACK, OR BLACK WITH BRUSHED ALUMINUM FACE.
LETTERS/CHEVRONS - MINIMUM 6" HIGH WITH 3/4" STROKE. PROVIDE CHEVRONS
AS INDICATED EITHER LEFT, RIGHT OR BOTH DIRECTIONS AS INDICATED.
CHEVRONS PUNCHED OUT THROUGH HOUSING AS REQUIRED.
EMERGENCY PACK - SOLID-STATE, CONSTANT-CURRENT TYPE BATTERY
CHARGER WITH MAINTENANCE-FREE, NICKEL-CADMIUM BATTERY, AC-ON
INDICATOR LAMP AND TEST SWITCH.
MOUNTING - UNIVERSAL MOUNTING KIT FOR CEILING, WALL OR END-OF-
FIXTURE MOUNTING.
ILLUMINATION - PROVIDED BY RED, GREEN OR WHITE HIGH-OUTPUT LEDS
INSIDE OF FIXTURE HOUSING. PROVIDE POLYSTYRENE DIFFUSER IN COLOR
INDICATED WITH FREQUENCY-MATCHED SILKSCREEN COATING FOR MAXIMUM
LED LIGHT OUTPUT.
CERTIFICATION - UL LISTED AND CERTIFIED FOR DAMP LOCATIONS.
THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A
LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT
INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LED EXIT SIGNXLED CANOPY LIGHT
LUMINAIRE REQUIREMENTS:
1.
2.
3.
4.
5.
6.
7.
HOUSING - ALUMINUM BODY WITH DIE CAST ALUMINUM END CAPS.
FINISH - FADE AND ABRASION RESISTANT, TRYGLYCIDAL ISOCYANURATE
(TGIC) TEXTURED POLYESTER POWDER-COAT FINISH, MEDIUM GRAY PAINT.
LIGHT SOURCE - SOLID STATE IP66 SEALED LED MODULES WITH MINIMUM
100K HOURS RATED LIFE AT L70, 4000K CCT UON, MINIMUM 80 CRI, AND
MINIMUM EFFICACY OF 122 LUMENS/WATT. INITIAL LUMEN OUTPUT AS
INDICATED IN LUMINAIRE SHEDULE.
DRIVER - INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120 OR 277V. THERMAL MANAGEMENT. ON-OFF
CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE INDICATED.
CERTIFICATION - IP65 RATED, SURGE PROTECTOR STANDARD IN
ACOORDANCE WITH IEEE/ANSI C62.41.2. DAMP LOCATION, ROHS
COMPLIANT, COMPLIES WITH LM79, LM80, AND TM21 TESTING STANDARDS.
MOUNTING - RECESSED
THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A
LUMINARE THATMAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT
INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
J LED WALL/ARM WALL WASH
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM FRAME AND HEAT SINK WITH SILVER OR WHITE
ENAMELED FINISH.
2. LENS - IMPACT-RESISTANT ACRYLIC.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
4000K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 75
4. DRIVER - REMOTELY-LOCATED ABOUT CEILING, REPLACEABLE, HIGH-EFFICIENCY
DRIVER WITH MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V, THERMAL
MANAGEMENT, < 20% TOTAL HARMONIC DISTORTION. ON-OFF CONTROL,
STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES WITH
LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - WALL MOUNT AND WALL MOUNTED ROTATIONAL ARM WITH 1"
ROTATIONAL HUB
7. OPTIONS - 0-10V OR DALI SYSTEM DIMMING.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
K
N
H
NC
HN
NO
LIGHTING
SWITCH
N H N
TEST
SWITCH
N
LIGHTING
SWITCH
NO
POWER PACK
EMERGENCY
POWER
PACK
3-WIRE
24VDC
SENSOR
POWER
PACK
LOAD3-WIRE
24VDC
SENSOR
FIRE ALARM
AUXILIARY RELAY
FIRE ALARM SHUNT
TRIP CIRCUIT
TO ADDITIONAL
EMERGENCY
POWER
PACKS
TO ADDITIONAL
SENSORS
TO ADDITIONAL
SENSORS
LOAD
HN
NO
LIGHTING
SWITCH
N
NO
POWER
PACK
EMERGENCY
POWER
PACK
3-WIRE
24VDC
SENSOR
TO ADDITIONAL
SENSORS
LOAD
TEST
SWITCHLIGHTING INVERTER
HN
HN
INPUT
OUTPUT
NOT TO SCALE
NOT TO SCALE
TYPICAL CONTROL WIRING DIAGRAM
TYPICAL CONTROL WIRING DIAGRAM WITH FIRE ALARM OVERRIDE
NOT TO SCALE
EMERGENCY CONTROL WIRING DIAGRAM
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:2
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
EL502
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
LI
G
H
TI
N G
D E
T A
IL
S
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E L q tu c k e r
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
324 358
12881106
FOR NOMINAL 2" SLIP FIT LUMINAIRE
ALUMINUM ARM
SINGLE ARM MOUNTING
DOUBLE ARM MOUNTING
PLAN
9"±
9.5"±
MOUNTING PLATE
"72"
"24"
9/16" KEY SLOT
FOR 1/2" THRU
BOLT
CABLE OPENING
POLE CAP
POLE CAP
1/2" DIA. THRU BOLTS
9/16" HOLE FOR
1/2" THRU BOLT
ALL MOUNTING HARDWARE FOR ARMS
SHALL BE HOT-DIP GALVANIZED.
NOTE:
LUMINAIRE MOUNTING ARMSANCHOR BASE ALUMINUM OR FIBERGLASS POLES
TAPERED ALUMINUM OR FIBERGLASS POLE. CROSS
SECTIONAL SHAPE AND COLOR AS INDICATED.
NOTES:
COORDINATE TOTAL EPA WITH SPECIFICATIONS.
WIRING HANDHOLE MINIMUM 2 1/2" X 5" CLEAR OPENING
WITH COVER AND STAINLESS STEEL SCREWS.
INTERNAL GROUNDING LUG.
TERMINATE C0NDUITS INTERNALLY, ADJACENT TO
HANDHOLE.
FULL BASE COVER - TW0 PIECE GALVANIZED STEEL.
CONCRETE FOUNDATION - SEE ANCHOR BASE POLE
FOUNDATION DETAIL
MAST ARM OPTION - COORDINATE WIRING AND BOLT HOLES
WITH MAST ARM PROVIDED.
1'-6"
25'-0"
9"
12"
LUMINAIRE REQUIREMENTS:
1. HOUSING - HEAVY-DUTY DIE CAST ALUMINUM OR DIE CAST AND EXTRUDED ALUMINUM.
HEAT SINK INCORPORATED DIRECTLY INTO HOUSING TO ENSURE MAXIMUM HEAT
TRANSFER AND DISSIPATION.
2. FINISH - MULTI-STAGE PRE-TREATMENT, FINISHED WITH BAKED-ON POLYESTER POWDER
COAT. STANDARD DARK BRONZE FINISH.
3. POWER SUPPLY/LED DIMMABLE DRIVER - PROVIDE IN SEPARATE COMPARTMENT
ACCESSIBLE WITHOUT THE USE OF HAND TOOLS. CLASS 1 DRIVER SHALL OPERATE AT
277 V, 50/60 Hz. POWER FACTOR GREATER THAN 0.9 AND THD LESS THAN 20% AT FULL
LOAD. MINIMUM EFFICACY SHALL BE 80 LM/W AT MAXIMUM 700 mA OPERATING CURRENT.
0-10V DIMMING CAPABILITIES.
4. LED OPTICAL ASSEMBLY - NUMBER OF LED ARRAYS SHALL VARY TO ACCOMMODATE
DESIRED LUMINAIRE OUTPUT. PROVIDE WITH EQUIVALENT NEMA TYPE II DISTRIBUTION AS
INDICATED. BUG UPLIGHT RATING OF U0, WITH BACKLIGHT AND GLARE RATINGS AS
DETERMINED BY LIGHTING ZONE INSTALLED. MINIMUM COLOR RENDERING INDEX (CRI)
SHALL BE 70 FOR CORRELATED COLOR TEMPERATURES (CCT) OF 4000 DEGREES K.
5. SURGE PROTECTION - 10 kV MINIMUM, COMPLIANT WITH ANSI C62.41.2.
6. CERTIFICATION - UL AND/OR ETL WET LOCATION LISTED, MINIMUM IP66 RATED PER
ANSI/IEC 60529, AND RoHS COMPLIANT.
7. PHOTOCELL AND RECEPTACLE, SHORTING CAP, BIRD SPIKES, AND STEP DIMMING DRIVER.
8. OTHER - THE ABOVE SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A
LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS AND IS NOT INTENDED
TO INDICATE A CERTAIN MANUFACTURER'S PREFERENCE. ALL DIMENSIONS ARE NOMINAL
AND VARY PER MANUFACTURER.
LED ROADWAY LUMINAIRE
ANCHOR BASE POLE FOUNDATION
"72"
4"
24"
FINISHED GRADE
INSULATED COPPER
GROUNDING CONDUCTOR
ATTACHED TO INTERNAL LUG
WELDED TO INTERIOR OF
POLE. SIZE PER NFPA 70.
HANDHOLE - SEE POLE SKETCH
AND SPECIFICATION
POLE - SEE POLE SKETCH AND
SPECIFICATION
SET TOP OF CONCRETE
FOUNDATION 4" ABOVE
GRADE
COPPER EQUIPMENT
GROUNDING
CONDUCTOR -
ATTACH TO INTERNAL
LUG WELDED TO
INTERIOR OF POLE.
CONDUCTOR TO BE
SAME SIZE AND TYPE
AS SUPPLY PHASE
CONDUCTOR.
CIRCUIT CONDUCTORS
AND CONDUIT TO
POWER SOURCE OR
NEXT POLE
CONCRETE PER
SPECIFICATION
CIRCUIT CONDUCTORS AND
CONDUIT TO POWER
SOURCE OR NEXT POLE
ANCHOR BOLTS AS
RECOMMENDED BY
MANUFACTURER OF POLE
#4 BARS VERTICAL AT
6" EACH FACE
#3 BARS AT 12" ON CENTER
HORIZONTALLY
3/4" X 10' GROUND ROD
Light Engine Housing
Latches (tool-less entry)
33.1"
10.6" (269mm)
4.7" (121mm )Cover
(842mm)
CONDUIT STUBBED UP
ADJACENT TO HANDHOLE;
NUMBER AND SIZE AS REQUIRED
G H
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:3
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
EL503
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
LI
G
H
TI
N G
D E
T A
IL
S
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E L q tu c k e r
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
325 358
12881107
G
6 TYPICAL
3 7
TYPICAL
TYPICAL
TYPICAL
45 5
SERVICE
DISCONNECT
PBB
0' 1' 5' 10' 15'1'
1/4"=1'-0"
PROVIDE 12" ALUMINUM AIR TERMINAL.
PROVIDE 24 STRANDS OF #14 AWG ALUMINUM.
PROVIDE A 3/4"x10'-0" COPPER-CLAD GROUND ROD.
PROVIDE A THROUGH-ROOF CONNECTOR TO AN
ALUMINUM DOWN CONDUCTOR AND TRANSITION TO A
COPPER DOWN CONDUCTOR WITH A BI-METAL
CONNECTOR.
PROVIDE 29 STRANDS OF #17 AWG COPPER.
PROVIDE A #4/0 COPPER GROUNDING COUNTERPOISE.
PROVIDE A 3/4"x10'-0" COPPER-CLAD GROUND ROD
WITHIN A GROUND ROD TEST WELL. MECHANICAL
CONNECTORS SHALL BE USED TO CONNECT LIGHTNING
PROTECTION CABLES TO GROUND ROD. SEE DETAIL ON
SHEET EG501 FOR MORE INFORMATION.
PROVIDE A #1/0 GROUND FROM SERVICE DISCONNECT TO
GROUNDING LOOP.
1.
2.
3.
4.
5.
6.
7.
8.
FOR LIGHTNING PROTECTION DETAILS, SEE SHEET EG501.
LIGHTNING PROTECTION SYSTEM SHALL BE INSTALL IN
ACCORDANCE WITH NFPA 70 AND NFPA 780.
A.
B.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:0
:3
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \V is it o rs
C e n te r\
W
P
C u tl e r_
V C
E
L E
C R
.r v t
EG101
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
V
IS
IT
O
R S
C O
N
TR
O L
C E
N
TE
R R
O O
F P
LA
N
LI
G H
TN
IN
G P
R O
TE
C
T
IO
N
HWBWQT WQT
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D I
C O
R E
E G q tu c k e r
SCALE: 1/4" = 1'-0"
ROOF PLAN - LIGHTNING PROTECTION
PLAN
NORTH
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
SHEET KEYNOTES
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
326 358
12881108
PANEL 'G'
1 TYPICAL
3 TYPICAL
2 TYPICAL
6 TYPICAL
B D EC
A
PBB
PROVIDE 12" ALUMINUM AIR TERMINAL.
PROVIDE 24 STRANDS OF #14 AWG ALUMINUM.
PROVIDE A 3/4"x10'-0" COPPER-CLAD GROUND ROD.
PROVIDE A THROUGH-ROOF CONNECTOR TO AN
ALUMINUM DOWN CONDUCTOR AND TRANSITION TO A
COPPER DOWN CONDUCTOR WITH A BI-METAL
CONNECTOR.
PROVIDE 29 STRANDS OF #17 AWG COPPER.
PROVIDE A #4/0 COPPER GROUNDING COUNTERPOISE.
PROVIDE A 3/4"x10'-0" COPPER-CLAD GROUND ROD
WITHIN A GROUND ROD TEST WELL. MECHANICAL
CONNECTORS SHALL BE USED TO CONNECT LIGHTNING
PROTECTION CABLES TO GROUND ROD. SEE DETAIL ON
SHEET EG501 FOR MORE INFORMATION.
PROVIDE A #1/0 GROUND FROM PANEL 'G' TO GROUND
LOOP.
1.
2.
3.
4.
5.
6.
7.
8.
FOR LIGHTNING PROTECTION DETAILS, SEE SHEET EG501.
LIGHTNING PROTECTION SYSTEM SHALL BE INSTALL IN
ACCORDANCE WITH NFPA 70 AND NFPA 780.
A.
B.
3/16" = 1'-0"
0'5' 5' 10'
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
TI
C
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
AS NOTED
F
IL
E N
A M
E
L A
Y O
U T
N A
M E
P
L O
T T
E D
U
S E
R
03/09/2023
/8
/2
:3
:5
P M
U P ro je c ts
\2
\2 -0
C u tl e r, M E
P e ri m e te r S e c u ri ty
\0
S U
B M
IT
T
A L S
\0
F in a l S ig n e d
M a r
\R e v it \I n s p e c ti o n S ta ti o n
W
P
C u tl e r_
IS
E L
E C
R
.r v t
EG102
P -3
P
E R
IM
E
TE
R
S E
C U
R
IT
Y
IN
S
P E
C T
IO
N
S
TA
T
IO
N , P
O V
, A N
D C
V
IS
R O
O F
P
LA
N
LI
G
H
TN
IN
G
P R
O
TE
C T
IO
N
HWBWQT WCJ
02/08/23
Approved by Jeffrey Hoyt, PWD ME, via Email
IM
P
R O
V E
M E
N
TS
CRH/LAF
1614700
N40085-19-D-9008 T008
C U
T
LE
R , M
A
IN
E
EJA
JAS
DSN
M
ID
L A
N T
D C
C O
R E
E G s fe a g in s
SCALE: 3/16" = 1'-0"
INSPECTION STATION, POV, AND CVIS ROOF PLAN - LIGHTNING PROTECTION
GENERAL SHEET NOTES
GRAPHIC…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .