1614700dwg22of22TELECOM_SECURITY_AUDIO.pdf

PDF 8 MB Posted

Attached to
P347 Perimeter Security Improvement, Portsmouth Naval Shipyard, NCTS Cutler, Maine
Solicitation number
N4008523R2539
Issued by

View the file

Other files

File Type Posted
Amendment 0012.pdf PDF
P-347 Price Proposal Form AMD 0012.pdf PDF
1614700Amend0011dwg.pdf PDF
P347 AMENDMENT 0011.pdf PDF
1614700Amend0011spc.pdf PDF
Prospect Harbor Canopy Drawings Calcs Data.pdf PDF
P347 AMENDMENT 0010.pdf PDF
P347 AMENDMENT 0009.pdf PDF
P347 J-A Interior Finishes Redacted.pdf PDF
1614700Amend0008spc.pdf PDF
P347 AMENDMENT 0008.pdf PDF
1614700Amend0008dwg.pdf PDF
P347 AMENDMENT 0007.pdf PDF
P347 AMENDMENT 0006.pdf PDF
09 26 00.pdf PDF
Uline IH-2769-SPFR.PDF PDF
08 14 00.pdf PDF
Uline IH-1119-SPFR.PDF PDF
P347 AMENDMENT 0005.pdf PDF
CS507 - FENCING DETAILS.pdf PDF
P347 AMENDMENT 0004.pdf PDF
1614700dwg08of22CIVIL_SIGNING_UTILITIES.pdf PDF
1614700dwg18of22FIRE.pdf PDF
1614700dwg04of22CIVIL_ALIGNMENT_DEMO.pdf PDF
1614700dwg14of22LANDSCAPING.pdf PDF
1614700dwg21of22ELECTRICAL.pdf PDF
1614700dwg15of22ENVIRONMENTAL.pdf PDF
1614700dwg01of22GENERAL.pdf PDF
1614700dwg10of22CIVIL_EROSION_02.pdf PDF
1614700dwg13of22WETLAND.pdf PDF
1614700dwg12of22CIVIL_EROSION_04.pdf PDF
1614700dwg11of22CIVIL_EROSION_03.pdf PDF
1614700spc1of1.pdf PDF
1614700dwg17of22ARCHITECTURAL_INTERIOR.pdf PDF
1614700dwg05of22CIVIL_SITE.pdf PDF
1614700dwg20of22MECHANICAL.pdf PDF
1614700dwg03of22EXISTING_CONDITION.pdf PDF
1614700dwg02of22HAZMAT_GEOTECH.pdf PDF
1614700dwg19of22PLUMBING.pdf PDF
1614700dwg09of22CIVIL_EROSION_01.pdf PDF
1614700dwg07of22CIVIL_GRADING_DRAINAGE_02.pdf PDF
1614700dwg06of22CIVIL_GRADING_DRAINAGE_01.pdf PDF
1614700dwg16of22STRUCTURAL.pdf PDF
P347 AMENDMENT 0003.pdf PDF
P347 AMENDMENT 0002.pdf PDF
P347 AMENDMENT 0001.pdf PDF
Cutler Site Access Requirements-NAVFAC Instructions.docx DOCX document
N4008523R2539 P347 AMENDMENT 01.pdf PDF
Cutler Site Access Requirements-Contractor Instructions.docx DOCX document
SECNAV_5512_1_dtd_May21.pdf PDF
Show 40 more

Latest 50 of 105 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

100A

J

G

HH

P

A1

TN401

JUNCTION BOX AND COVER PLATE FOR SERVICE AS INDICATED.

CABLE TELEVISION OUTLET, MOUNT 18" AFF, UON. PROVIDE 1" EMPTY CONDUIT

WITH PULLSTRING AND ROUTE BACK TO TELECOMMUNICATIONS ROOM.

LEGEND AND ABBREVIATIONS

PANELBOARD - 208Y/120V.

FEET

FIRE ALARM CONTROL PANEL

EXISTING

FT

FACP

EXIST

UNLESS OTHERWISE NOTED

W WIRE

V

UON

VOLTS

TELEVISIONTV

TELEPHONETEL

CABLE TELEVISION

EQUIPMENT

EMPTY CONDUIT

CLOSED CIRCUIT TELEVISION

DRAWING

CIRCUIT

CONDUIT

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AMERICAN WIRE GAUGE

BUILDING

EQUIP

EC

DWG

CKT

CCTV

BLDG

CATV

C

AWG

AFG

AFF

RIGID GALVANIZED STEEL

REQUIRED

RECEPTACLE

RGS

REQ'D

REC.

POLY VINYL CHLORIDE

PHASE

PVC

PH, ∅

P POLE

NORMALLY CLOSED

NORMALLY OPEN

NEUTRALNEU

NO

NC

MOUNTED

MOUNT

MTD

MT

THOUSAND CIRCULAR MILS

KILOWATT HOUR

KILOVOLT AMPEREKVA

KWH

KCMIL

REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL PLANS FOR ADDITIONAL ABBREVIATIONS.

ABV ABOVE

CTB COMMUNICATIONS

TERMINAL BACKBOARD

TELECOMMUNICATIONS SERVER RACK.

CONSTRUCTION SHEET KEYNOTE DESIGNATION.

GENERAL NOTES

A. BEFORE INSTALLATION OF TELECOMMUNICATIONS EQUIPMENT, CONDUIT,

AND CABLING, CONTRACTOR MUST FAMILIARIZE THEMSELVES WITH

CUTLER'S TELECOMMUNICATIONS BUILDING CABLING SYSTEM STANDARDS.

B. CABLING AND TERMINATIONS MUST BE CAT 6 UNSHIELDED TWISTED PAIR

(UTP) AND MUST BE IN ACCORDANCE WITH TIA-568.

C. WHERE EMPTY CONDUITS ARE INSTALLED, PROVIDE WITH PULLSTRING FOR

FUTURE INSTALLATION OF CABLES.

D. COPPER CONNECTIONS MUST BE TIA/EIA CAT6, 8-PIN/8 POSITION

INSULATION DISPLACEMENT TERMINATIONS WIRED T568A AS PER TIA-568.

E. CONTRACTOR MUST FIELD COORDINATE WITH OTHER TRADES WHEN

INSTALLING THE CABLE TRAY SYSTEM FOR MAXIMUM ALLOWANCE OF

CLEARANCE.

F. CONTRACTOR MUST PROVIDE A SYSTEM FOR ATTACHING AND

PROTECTING OUTLET LABELS ON FACEPLATES. LABELING SYSTEM FOR

COMMUNICATIONS OUTLETS, PATCH PANELS, AND DISTRIBUTION SYSTEM

MUST BE LABELED IN ACCORDANCE WITH TIA-606.

G. NON-CONTINUOUS CABLE SUPPORTS (J-HOOK, ETC.) CAN BE USED FOR THE

ROUTING OF CABLES TO CABLE TRAYS WITHIN SPACES. NON-CONTINUOUS

CABLE SUPPORTS MUST NOT BE USED IN PLACE OF THE CABLE TRAY

SYSTEM AND MUST COMPLY WITH BASE TELECOMMUNICATION BUILDING

CABLING STANDARDS.

H. CONTRACTOR MUST COORDINATE THE PURCHASE AND INSTALLATION OF

THE EQUIPMENT RACKS WITH THE GOVERNMENT'S TELECOMMUNICATIONS

DIVISION.

I. ALL CABLE LADDER RACKS MUST BE BONDED TOGETHER AND GROUNDED

TO THE GROUNDING BUSBAR WITHIN THE COMM ROOM IN WHICH THEY

RESIDE.

J. ALL OUTLET BOXES FOR TELECOMMUNICATIONS MUST BE 4-11/16"

SQUARED BY 2-1/8" DEEP AND MUST RECEIVE (4) JACK INSTALLATIONS.

K. INDIVIDUAL SERIES SIX RG-6/U COAX CABLE MUST BE PROVIDED FROM

IT/COMM ROOM BACKBOARD TO EACH CATV OUTLET. CABLES MUST BE

BONDED FOIL WITH TRI-SHIELD CONSTRUCTION, 77% BRAID, NON-BONDED

TAPE, WITH FLAME RETARDANT PVC JACKET AND MUST MEET NEC 820 V

RATING. F TYPE CONNECTORS MUST BE PROVIDED AT BOTH ENDS OF ALL

CABLES.

L. ALL CABLE TRAYS AND TELECOMMUNICATIONS CONDUITS MUST BE

BONDED AND GROUNDED.

PE POLYETHYLENE

SHEET LOCATION

SHEET

NUMBER

ENLARGED REFERNCE

GROUNDGND

RADIO FREQUENCYRF

AUDIO VISUALAV

NATIONAL ELECTRIC CODENEC

MILLIMETERMM

TYPICALTYP

HANDHOLEHH

GFGI GOVERNMENT FURNISHED

GOVERNMENT INSTALLED

HANDHOLE.

UNDERWRITERS LABORATORIESUL

HIGH SECURITY SWITCHESHSS

TIA TELECOMMUNICATIONS

INDUSTRY ASSOCIATION

EIA U.S. ENERGY INFORMATION

ADMINITRATION

COMMUNICATIONSCOMM

COMMUNICATIONS TERMINAL BACKBOARD. A-C GRADE PLYWOOD FIRE

RETARDANT TREATED MOUNTED WITH GRADE A SIDE EXPOSED. PAINT

BACKBOARD WITH TWO COATS OF FIRE-RETARDANT PAINT. MOUNT BOTTOM 8"

AFF, UON. OVERALL LENGTH AS INDICATED ON PLANS.

SINGLE-MODE FIBER OPTIC CABLESMFOC

ACEG ALTERNATING CURRENT

EQUIPMENT GROUND

BCT BONDING CONDUCTOR

FOR

TELECOMMUNICATIONS

GROUNDING ELECTRODE CONDUCTORGEC

OUTSIDE PLANTOSP

LPR LICENSE PLATE RECOGNITION

COMMUNICATIONS OUTLET (TWO CAT6 JACKS). MOUNT 48"

AFF. SUBSCRIPT "W" WHEN SHOWN INDICATES A WALL

MOUNTED TELEPHONE OUTLET.

SINGLE GANG OUTLET BOX WITH (4) CATEGORY 6 (CAT6) JACKS

FOR UNSECURE DATA OR VOICE, UON. MOUNT 18" AFF, UON.

UNDERGROUND TELECOMMUNICATIONS.

LAN LOCAL AREA NETWORK

EMERGENCY FAS OPERATION (RED PUSH BUTTON). MOUNT 48" AFF, UON.

DOOR DESIGNATION.

TELECOMMUNICATIONS PRIMARY BONDING BUSBAR (PBB).

UT

BASKET-TYPE CABLE TRAY, SIZE AS INDICATED.

CABLE LADDER, SIZE AS INDICATED.

TELECOMMUNICATIONS SERVER RACK, WALL MOUNTED.

PANELBOARD - 480Y/277V.

PBC PRIMARY BONDING CONDUCTOR

SINGLE GANG OUTLET BOX WITH (4) CATEGORY 6 (CAT6) JACKS

FOR SECURE DATA OR VOICE, UON. MOUNT 18" AFF, UON.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:0

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TN001

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

TE

LE

C O

M M

U N

IC

A

TI

O

N S

L E

G E

N D

, N O

TE

S

A

B B

R E

V

IA

T

IO

N S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T N q tu c k e r

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881119 337 358

B1

B1

A

B1

B140

B1

B1

DRY

HYDRANT

AND POND

EXIST SALT

SHED

B132

SALT WATER

HOLDING

TANK

B103 POWER

PLANT

B123

B124

B121

B100

TRANSMITTER

BLDG

B1

2,400'800' 1,600'800' 400' 0 1" = 800'-0"

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

CU

TL

ER

, M

AI

NE

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P R

O V

E M

E N

TS

02/08/2023

CRH/LAF

EJA

DSN

1614700

N40085-19-D-9008 T008

JP HARVEY

ENGINEERING SOLUTIONS

JPHES.COM | 757.722.7074

29 KINGS WAY, HAMPTON, VA

JAS

03/09/2023

Approved By Jeffrey Hoyt, PWD ME, via Email

MACHIAS BAY

MACHIAS BAY

LITTLE MACHIAS BAY

OVERALL SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND SECURITY

WQT WQT JAW

TS101

GRAPHIC SCALE

GENERAL NOTES

A. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

FAMILIARIZE THEMSELVES WITH THE EXISTING SITE

CONDITIONS.

B. ALL EMPTY CONDUITS MUST BE PROVIDED WITH FIBER

MESH INNERDUCT.

C. SEE CIVIL DRAWINGS FOR LIMITS OF FENCE

CONSTRUCTION.

D. MAXIMUM SPACING OF TELECOMMUNICATIONS

HANDHOLES MUST BE NO MORE THAN 1000'-0" APART.

E. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

COORDINATE WITH BUILDING 100 SITE REPRESENTATIVE

FOR ROUTING OF NEW DUCTBANKS, INSTALLATION OF

HANDHOLES, ROUTING OF POWER, ROUTING OF FIBER

OPTIC CABLING WITHIN NEW AND EXISTING DUCTBANKS,

AND ROUTING OF FIBER OPTIC CABLING INTO ALL

FACILITIES.

F. CONTRACTOR MUST CAREFULLY WORK AROUND THE

EXISTING MESH GROUNDING GRID WITHIN THE SECURE

AREA OF THE SITE. ANY DAMAGED GROUNDING CABLES

MUST BE REPAIRED AT THE EXPENSE OF THE

CONTRACTOR. SEE SHEET TN502 FOR DETAILS ON

REPAIRING THE EXISTING GROUNDING GRID.

G. ALL RADAR EQUIPMENT MUST BE AT A MINIMUM OF 3'-0"

ABOVE THE 14'-0" FLOOD PLAIN.

H. SEE SHEETS TY501 THROUGH TY507 FOR SECURITY

DETAILS AND DIAGRAMS.

SHEET KEYNOTES

1. PROVIDE 96-STRANDS OF SINGLE-MODE FIBER OPTIC

CABLE (SMFOC) AND ROUTE THROUGH EXISTING

CONDUIT INFRASTRUCTURE. ROUTE FIBER OPTIC

CABLING TO BUILDING 129.

2. PROVIDE A 4'X4'X4' HANDHOLE PULLING POINT FOR

TELECOMMUNICATIONS CONDUITS.

3. PROVIDE ONE 96-STRAND BUNDLE FOR ENTRY CONTROL

FACILITY SITE AND 24-STRANDS OF SMFOC FROM B102

NORTH HELIX HOUSE TO BUILDING 100. ROUTE FIBER

OPTIC CABLE THROUGH EXISTING PATHWAYS AND

PARTIALLY THROUGH EXISTING TUNNEL SYSTEM.

4. PROVIDE 24-STRANDS OF SMFOC FROM B101 SOUTH

HELIX HOUSE TO BUILDING 100 THROUGH EXISTING

PATHWAYS AND PARTIALLY THROUGH EXISTING TUNNEL

SYSTEM.

5. ROUTE 96-STRANDS OF SMFOC FROM B103 POWER

PLANT TO BUILDING 100 WITHIN AN EXISTING SPARE

TELECOMMUNICATIONS DUCT.

6. PROVIDE A MID-RANGE RADAR DETECTION SYSTEM WITH

A MID-RANGE MULTI SENSOR CALIBRATED TO PROVIDE

SURVEILLANCE 0.25 MILES BEYOND THE COAST LINE.

RADAR DETECTION SYSTEM MUST INTEGRATE WITH

CCTV SYSTEM.

7. PROVIDE 6-STRANDS OF SMFOC FROM NORTH HELIX

HOUSE TO RADAR DETECTION EQUIPMENT. COORDINATE

WITH SITE REPRESENTATIVE FOR ROUTING OF 240V

POWER FROM NEAREST POWER STATION AT TOWER.

8. PROVIDE 6-STRANDS OF SMFOC FROM BUILDING 100 TO

RADAR DETECTION EQUIPMENT. COORDINATE WITH SITE

REPRESENTATIVE FOR ROUTING OF 240V POWER FROM

BUILDING 103.

9. PROVIDE 6-STRANDS OF SMFOC FROM SOUTH HELIX

HOUSE TO RADAR DETECTION EQUIPMENT. COORDINATE

WITH SITE REPRESENTATIVE FOR ROUTING OF 240V

POWER FROM NEAREST POWER STATION AT TOWER.

10. PROVIDE (2) 4" CONDUITS DIRECT-BURIED ALONG SIDE

OF HUDSON BOULEVARD AND PROVIDE 96-STRANDS OF

SINGLE-MODE FIBER OPTIC CABLE (SMFOC) AND ROUTE

TO BUILDING 129.

11. PROVIDE A FIXED RADAR/CAMERA DETECTION SYSTEM

CALIBRATED TO PROVIDE SURVEILLANCE WITHIN

INTERIOR AREA OF PENINSULA. RADAR DETECTION

SYSTEM MUST INTEGRATE WITH CCTV SYSTEM.

12. PROVIDE A MID-RANGE RADAR DETECTION SYSTEM WITH

A MID-RANGE MULTI SENSOR AT ECF AREA FOR

COVERAGE TO THE NORTH OF THE INSTALLATION.

COORDINATE WITH GOVERNMENT FOR FINAL LOCATION.

EQUIPMENT MUST BE MOUNTED ON A 30'-0" POLE FOR

MAXIMUM COVERAGE BEYOND THE NORTHERN SIDE OF

THE INSTALLATION. RADAR DETECTION SYSTEM MUST

INTEGRATE WITH CCTV SYSTEM.

13. PROVIDE 6-STRANDS OF SMFOC FROM INSPECTION

BUILDING AT ECF TO RADAR DETECTION EQUIPMENT.

COORDINATE WITH SITE REPRESENTATIVE FOR ROUTING

OF 240V POWER FROM THE INSPECTION STATION OR THE

OVERWATCH POSITION PANEL.

SHEET TS102

SHEET TS103

SHEET TS103

SHEET TS104

SHEET TS105

6 9

8 11

6 8

12 13

12881120 338 358

RIDGE ROAD

T

RID

GE R

OAD

W

W

W

W

DY

H

CP

C P

VISITORS CONTROL CENTER

INSPECTION STATION, POV, AND

CVIS BUILDING

CC

CC10

134135132

CC

EXISTING POWER POLE

CC

GRAPHIC SCALE

1" = 50'-0"

30' 0 25' 50' 100' 150'

ENTRY CONTROL FACILITY SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND SECURITY

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

CU

TL

ER

, M

AI

NE

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P R

O V

E M

E N

TS

02/08/2023

CRH/LAF

EJA

DSN

1614700

N40085-19-D-9008 T008

JP HARVEY

ENGINEERING SOLUTIONS

JPHES.COM | 757.722.7074

29 KINGS WAY, HAMPTON, VA

JAS

03/09/2023

Approved By Jeffrey Hoyt, PWD ME, via Email

WQT WQT JAW

TS102

GENERAL NOTES

A. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

FAMILIARIZE THEMSELVES WITH THE EXISTING SITE

CONDITIONS.

B. ALL EMPTY CONDUITS MUST BE PROVIDED WITH FIBER

MESH INNERDUCT.

C. MAXIMUM SPACING OF TELECOMMUNICATIONS

HANDHOLES MUST BE NO MORE THAN 1000'-0" APART.

D. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

COORDINATE WITH BUILDING 100 SITE REPRESENTATIVE

FOR ROUTING OF NEW DUCTBANKS, INSTALLATION OF

HANDHOLES, ROUTING OF FIBER OPTIC CABLING WITHIN

EXISTING DUCTBANKS, AND ROUTING OF FIBER OPTIC

CABLING INTO ALL FACILITIES.

E. FOR CAMERA LAYOUT IN INSPECTION LANES, SEE

SHEET TY102 FOR MORE INFORMATION.

SHEET KEYNOTES

1. PROVIDE (2) 4" PVC CONDUITS AND DIRECT-BURY.

PROVIDE ONE CONDUIT WITH 96-STRANDS OF

SINGLE-MODE FIBER OPTIC CABLE (SMFOC) AND THE

OTHER CONDUIT WILL BE A SPARE.

2. PROVIDE (3) 4" CONDUITS WITH ONE CONDUIT WITH

96-STRAND BUNDLE FROM B100 AND 12-STRAND BUNDLE

FROM GATEHOUSE.

3. PROVIDE (3) 4" CONDUITS WITH ONE CONDUIT WITH

24-STRAND BUNDLE FROM VISITORS CENTER AND ONE

CONDUIT WITH CABLING FROM OVERWATCH AREA.

ROUTE INTO COMM ROOM WITHIN GATEHOUSE. PROVIDE

(1) 2" CONDUIT EMPTY CONDUIT WITH PULLSTRING FROM

HANDHOLE INTO BUILDING FOR CATV.

4. FOR CONTINUATION, SEE SHEET TS101.

5. PROVIDE A 4'X4'X4' TELECOMMUNICATIONS HANDHOLE

PULLING POINT FOR CONDUITS.

6. PROVIDE A DOME-TYPE SECURITY CAMERA WITH

INTERNAL CAMERAS FOR A 270 DEGREE OF COVERAGE

OF ENTRY CONTROL FACILITY SITE. MOUNT SECURITY

CAMERA ON EXISTING POWER POLE. COORDINATE

MOUNTING HEIGHT AND ADJUST ON POLE TO AVOID

CONTACT WITH EQUIPMENT AND POWER LINES. THE

INSPECTION STATION MUST BE THE MONITORING AND

CONTROL POINT FOR THIS LOCATION.

7. OUTBOUND LANE FOR SLIDING GATE MUST BE

PROGRAMMED WITH A TAILGATING FEATURE. SLIDING

GATE FOR OUTBOUND LANE MUST OPEN 15'-0" UNDER

NORMAL OPERATION AND AN ADDITIONAL 6'-0" WHEN

MANUAL OVERRIDE IS ACTIVATED FOR VEHICLES WITH

HAULING OVERSIZED LOADS.

8. PROVIDE A 1" CONDUIT BETWEEN PEDESTALS FOR

ROUTING OF CABLING.

9. ROUTE CABLING FROM PEDESTALS IN A 2" CONDUIT TO

TELECOMMUNICATIONS HANDHOLE.

10. PROVIDE A HIGH/LOW PEDESTAL ON ACCESS CONTROL

ISLAND WITH A CARD READER/KEYPAD, INTERCOM, AND

FACIAL RECOGNITION CAMERA. BUILDING 100 & THE

GUARDHOUSE MUST BE THE MONITORING AND CONTROL

POINTS FOR THIS LOCATION. SEE DETAIL ON SHEET

TY502 FOR HIGH/LOW PEDESTAL.

11. PROVIDE A PEDESTAL WITH A CARD READER/KEYPAD,

INTERCOM, AND FACIAL RECOGNITION CAMERA. ROUTE

CABLING IN A 1" CONDUIT BACK TO

TELECOMMUNICATIONS ROOM IN BUILDING 129. THE

INSPECTION STATION MUST BE THE MONITORING AND

CONTROL POINT FOR THIS LOCATION. THIS PEDESTAL

MUST PROVIDE ACCESS CONTROL TO PEDESTRIAN GATE

BEHIND BUILDING 129.

12. STRUT SUPPORT SYSTEM. PROVIDE AN INTERCOM, AN

AVB EMERGENCY FAST OPERATION (EFO) PUSH BUTTON

AND A DURESS BUTTON AND MOUNT TO STRUCTURE.

PROVIDE DEVICES WITHIN A LOCKABLE NEMA 4X

ENCLOSURE FOR PROTECTION FROM ENVIRONMENT.

ROUTE CONTROL AND INTERCOM CABLING IN A 2"

CONDUIT TO HANDHOLE.

13. ROUTE CABLING FROM PEDESTALS AND STRUT

SUPPORT SYSTEM IN A 4" PVC CONDUIT FROM

TELECOMMUNICATIONS HANDHOLE TO

TELECOMMUNICATIONS ROOM IN INSPECTION STATION

BUILDING.

14. PROVIDE A DOME-TYPE SECURITY CAMERA WITH

INTERNAL CAMERAS FOR A 270 DEGREE OF COVERAGE

OF THE BACK OF THE INSPECTION STATION. MOUNT

SECURITY CAMERA ON NEW SITE LIGHTING POLE BEING

INSTALLED. ADJUST CAMERA ACCORDINGLY FOR

OPTIMAL VIEWING ANGLES OF THE BACK OF THE

INSPECTION STATION AS WELL AS SURROUNDING

AREAS. THE INSPECTION STATION MUST BE THE

MONITORING AND CONTROL POINT FOR THIS LOCATION.

15. PROVIDE A STATIONARY SECURITY CAMERA AIMED AT

INCOMING TRAFFIC TO INSTALLATION. MOUNT SECURITY

CAMERA ON NEW SITE LIGHTING POLE BEING INSTALLED.

ADJUST CAMERA ACCORDINGLY FOR OPTIMAL VIEWING

OVER MAIN GATE AND AIMED AT INCOMING TRAFFIC. THE

INSPECTION STATION MUST BE THE MONITORING AND

CONTROL POINT FOR THIS LOCATION.

12881121 339 358

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

GG

G

G G

G G

G G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

S-0

STEELES AVENUE

STEELES AVENUE

(G

RAVEL)

C

G

G

G

G

G

G

G

G

G

GG

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G

G G

G G

G G

G G

G G

G

N-0

RIDGE ROAD

ST.LAURENT STREET

ST

.L

AU

RE

NT

S

TR

EE

T

HUNTL

EY

H

OLL

ER

R

OAD

(GRAVEL)

(G

RA

VE

L)

C

B102 NORTH HELIX

HOUSE

B101 SOUTH HELIX HOUSE

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

CU

TL

ER

, M

AI

NE

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P R

O V

E M

E N

TS

02/08/2023

CRH/LAF

EJA

DSN

1614700

N40085-19-D-9008 T008

JP HARVEY

ENGINEERING SOLUTIONS

JPHES.COM | 757.722.7074

29 KINGS WAY, HAMPTON, VA

JAS

03/09/2023

Approved By Jeffrey Hoyt, PWD ME, via Email

WQT WQT JAW

TS103

GRAPHIC SCALE

1" = 50'-0"

30' 0 25' 50' 100' 150'

B101 SOUTH HELIX HOUSE SITE PLAN - TELECOMMUNICATIONS

(OSP) AND SECURITY

B102 NORTH HELIX HOUSE SITE PLAN - TELECOMMUNICATIONS

(OSP) AND SECURITY

GENERAL NOTES

A. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

FAMILIARIZE THEMSELVES WITH THE EXISTING SITE

CONDITIONS.

B. ALL EMPTY CONDUITS MUST BE PROVIDED WITH

FIBER MESH INNERDUCT.

C. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

COORDINATE WITH BUILDING 100 SITE

REPRESENTATIVE FOR ROUTING OF NEW

DUCTBANKS, INSTALLATION OF HANDHOLES, ROUTING

OF FIBER OPTIC CABLING WITHIN EXISTING

DUCTBANKS, AND ROUTING OF FIBER OPTIC CABLING

INTO ALL FACILITIES.

D. ALL FIBER OPTIC CABLING INSTALLED MUST NOT

HAVE TRACER WIRE.

F. CONTRACTOR MUST CAREFULLY WORK AROUND THE

EXISTING MESH GROUNDING GRID WITHIN THE

SECURE AREA OF THE SITE. ANY DAMAGED

GROUNDING CABLES MUST BE REPAIRED AT THE

EXPENSE OF THE CONTRACTOR. SEE SHEET TN502

FOR DETAILS ON REPAIRING THE EXISTING

GROUNDING GRID.

G. CCTV CAMERAS SHOWN ON THIS DRAWING MUST BE

MONITORED AND CONTROLLED FROM BUILDING 100

AND GUARDHOUSE AT ENTRY CONTROL FACILITY.

FINAL LOCATIONS MUST BE COORDINATED BETWEEN

THE SECURITY VENDOR AND THE GOVERNMENT.

SHEET KEYNOTES

1. FOR CONTINUATION, SEE SHEET TS101.

2. PROVIDE ONE 96-STRAND BUNDLE FOR ENTRY

CONTROL FACILITY SITE AND 24-STRANDS OF SMFOC

FROM B102 NORTH HELIX HOUSE TO BUILDING 100.

ROUTE FIBER OPTIC CABLING THROUGH EXISTING

CONDUIT INFRASTRUCTURE.

3. PROVIDE ONE 24-STRANDS OF SMFOC FROM B101

SOUTH HELIX HOUSE TO BUILDING 100. ROUTE FIBER

OPTIC CABLING THROUGH EXISTING CONDUIT

INFRASTRUCTURE.

4. PROVIDE A CCTV CAMERA ON ROOF OF HELIX HOUSE.

PROVIDE CAMERA WITH INTEGRAL THERMAL IMAGING

FOR DETECTION AT NIGHT OR DURING FOGGY

CONDITIONS. CAMERA MUST BE PROVIDED WITH

PROTECTION FROM FALLING ICE FROM ABOVE DURING

DE-ICING CONDITIONS.

5. PROVIDE A CCTV CAMERA AT ENTRANCE OF TUNNEL

LEADING TO BUILDING 100. PROVIDE A SEPARATE

INFRARED ILLUMINATOR FOR OPERATION IN

COMPLETE DARKNESS. CAMERA MUST BE MONITORED

ONLY FROM BUILDING 100 CONTROL ROOM.

6. PROVIDE A BALANCED MAGNETIC SWITCH ON THE

TUNNEL DOOR. TUNNEL DOOR MUST BE MONITORED

ONLY FROM BUILDING 100 CONTROL ROOM.

COORDINATE PHYSICAL IMPACT REQUIRED WITH SHPO

PRIOR TO INSTALLATION.

7. PROVIDE ONE 24-STRAND BUNDLE OF SMFOC FROM

B102 NORTH HELIX HOUSE TO BUILDING 100.

12881122 340 358

ZONE F

G

GGGGGGG

G G

G G

G G

G

G

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

GGGGGGGGGGGGGGGGG

GGGGGGGGGGGGGGGGG

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

S-11

RIDGE ROAD

RIDGE ROAD

ST

. L

AU

RE

NT

S

TR

EE

T

ZONE F

ZONE B-2

ZONE F

ZONE B-2

BUILDING 100

B296

B298

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

CU

TL

ER

, M

AI

NE

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P R

O V

E M

E N

TS

02/08/2023

CRH/LAF

EJA

DSN

1614700

N40085-19-D-9008 T008

JP HARVEY

ENGINEERING SOLUTIONS

JPHES.COM | 757.722.7074

29 KINGS WAY, HAMPTON, VA

JAS

03/09/2023

Approved By Jeffrey Hoyt, PWD ME, via Email

WQT WQT JAW

TS104

120'0' 1"=60'-0"

60' 240'180' 300'

GRAPHIC SCALE

BUILDING 100 SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND SECURITY

GENERAL NOTES

A. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

FAMILIARIZE THEMSELVES WITH THE EXISTING SITE

CONDITIONS.

B. ALL EMPTY CONDUITS MUST BE PROVIDED WITH FIBER

MESH INNERDUCT.

C. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

COORDINATE WITH BUILDING 100 SITE

REPRESENTATIVE FOR ROUTING OF NEW DUCTBANKS,

INSTALLATION OF HANDHOLES, ROUTING OF FIBER

OPTIC CABLING WITHIN EXISTING DUCTBANKS, AND

ROUTING OF FIBER OPTIC CABLING INTO ALL

FACILITIES.

D. ALL FIBER OPTIC CABLING INSTALLED MUST NOT HAVE

TRACER WIRE.

F. CONTRACTOR MUST CAREFULLY WORK AROUND THE

EXISTING MESH GROUNDING GRID WITHIN THE SECURE

AREA OF THE SITE. ANY DAMAGED GROUNDING CABLES

MUST BE REPAIRED AT THE EXPENSE OF THE

CONTRACTOR. SEE SHEET TN502 FOR DETAILS ON

REPAIRING THE EXISTING GROUNDING GRID.

G. CCTV CAMERAS SHOWN ON THIS DRAWING MUST BE

MONITORED AND CONTROLLED FROM BUILDING 100

AND GUARDHOUSE AT ENTRY CONTROL FACILITY.

FINAL LOCATIONS MUST BE COORDINATED BETWEEN

THE SECURITY VENDOR AND THE GOVERNMENT.

SHEET KEYNOTES

1. FOR CONTINUATION, SEE SHEET TS101.

2. PROVIDE ONE 96-STRAND BUNDLE FOR ENTRY

CONTROL FACILITY SITE AND 24-STRANDS OF SMFOC

FROM B102 NORTH HELIX HOUSE TO BUILDING 100.

ROUTE FIBER OPTIC CABLE THROUGH EXISTING

PATHWAYS AND THROUGH EXISTING TUNNEL SYSTEM.

3. PROVIDE ONE 24-STRAND BUNDLE OF SMFOC FROM

B101 SOUTH HELIX HOUSE TO BUILDING 100. ROUTE

FIBER OPTIC CABLE THROUGH EXISTING PATHWAYS

AND THROUGH EXISTING TUNNEL SYSTEM.

4. ROUTE FIBER OPTIC CABLING FROM EXISTING

MANHOLE TO BUILDING THROUGH AN EXISTING DUCT.

5. ROUTE ONE 96-STRAND BUNDLE OF SMFOC FROM

BUILDING 103 TO BUILDING 100 IN AN EXISTING DUCT

BETWEEN MANHOLES.

6. PROVIDE FIBER OPTIC COMBINATION DISTRIBUTION

PATCH PANELS FOR TERMINATING CABLES. INSTALL

PATCH PANELS IN EXISTING SERVER RACKS IN

TELECOMMUNICATIONS ROOM. COORDINATE WITH

BUILDING 100 REPRESENTATIVE WITH PLACEMENT OF

EQUIPMENT.

7. PROVIDE A CCTV CAMERA AT ROOF LEVEL OF

BUILDING 103 WITH A 270 DEGREE COVERAGE.

PROVIDE CAMERA WITH INTEGRAL THERMAL IMAGING

FOR DETECTION AT NIGHT OR DURING FOGGY

CONDITIONS.

12881123 341 358

SALT WATER

HOLDING

TANK

B103 POWER

PLANT

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

DES DRW

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

DRAWFORM REVISION: 25 AUGUST 2020

CHK

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

CU

TL

ER

, M

AI

NE

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P R

O V

E M

E N

TS

02/08/2023

CRH/LAF

EJA

DSN

1614700

N40085-19-D-9008 T008

JP HARVEY

ENGINEERING SOLUTIONS

JPHES.COM | 757.722.7074

29 KINGS WAY, HAMPTON, VA

JAS

03/09/2023

Approved By Jeffrey Hoyt, PWD ME, via Email

WQT WQT JAW

TS105

BUILDING 103 SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND SECURITY

40'0' 1"=20'-0"

20' 80'60' 100'

GRAPHIC SCALE

GENERAL NOTES

A. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

FAMILIARIZE THEMSELVES WITH THE EXISTING SITE

CONDITIONS.

B. ALL EMPTY CONDUITS MUST BE PROVIDED WITH FIBER

MESH INNERDUCT.

C. PRIOR TO CONSTRUCTION, THE CONTRACTOR MUST

COORDINATE WITH BUILDING 100 SITE REPRESENTATIVE

FOR ROUTING OF NEW DUCTBANKS, INSTALLATION OF

HANDHOLES, ROUTING OF FIBER OPTIC CABLING WITHIN

EXISTING DUCTBANKS, AND ROUTING OF FIBER OPTIC

CABLING INTO ALL FACILITIES.

D. ALL FIBER OPTIC CABLING INSTALLED MUST NOT HAVE

TRACER WIRE.

E. CCTV CAMERAS IN THIS AREA MUST REPORT BACK TO

THE VISITORS CONTROL CENTER SECURITY SYSTEM

AND MUST BE MONITORED FROM THE INSPECTION

STATION, FROM BUILDING 101 CONTROL ROOM AND

ALSO FROM BUILDING 103 CONTROL ROOM.

F. CONTRACTOR MUST CAREFULLY WORK AROUND THE

EXISTING MESH GROUNDING GRID WITHIN THE SECURE

AREA OF THE SITE. ANY DAMAGED GROUNDING CABLES

MUST BE REPAIRED AT THE EXPENSE OF THE

CONTRACTOR. SEE SHEET TN502 FOR DETAILS ON

REPAIRING THE EXISTING GROUNDING GRID.

G. CCTV CAMERAS SHOWN ON THIS DRAWING MUST BE

MONITORED AND CONTROLLED FROM BUILDING 100 AND

GUARDHOUSE AT ENTRY CONTROL FACILITY. FINAL

LOCATIONS MUST BE COORDINATED BETWEEN THE

SECURITY VENDOR AND THE GOVERNMENT.

SHEET KEYNOTES

1. FOR CONTINUATION, SEE SHEET TS101.

2. ROUTE 96-STRANDS OF SMFOC FROM BUILDING 103

POWER PLANT TO BUILDING 100 WITHIN AN EXISTING

SPARE TELECOMMUNICATIONS DUCT.

3. PROVIDE A CCTV CAMERA AT ROOF LEVEL OF BUILDING

103 WITH A 270 DEGREE COVERAGE. PROVIDE CAMERA

WITH INTEGRAL THERMAL IMAGING FOR DETECTION AT

NIGHT OR DURING FOGGY CONDITIONS.

4. PROVIDE FIBER OPTIC COMBINATION DISTRIBUTION

PATCH PANEL FOR TERMINATING CABLES. INSTALL

PATCH PANEL IN EXISTING SERVER RACK IN

TELECOMMUNICATIONS ROOM. COORDINATE WITH

BUILDING 100 REPRESENTATIVE WITH PLACEMENT OF

EQUIPMENT.

12881124 342 358

R E

F

FACP

G

FDS

MECH/ELEC

VESTIBULE

TOILET

MUD ROOM

COMM

116LOCKER ROOM

WAITING

OFFICE

INTERVIEW

OFFICE

120MOTHER'S

SHOWER

ADMIN/COPY

SIPRNET

EXIST

BREAKROOM

WALL-MOUNTED

SECURE SERVER

CABINET

'CTB'

TOILET

JANITOR

DAYROOM

HALLWAY

HALLWAY

LAUNDRY

HALLWAY

TN101

2"x8" BASKET TYPE

CABLE TRAY (TYPICAL)

IDS PANEL

ACS PANEL

DDC

PANEL

0' 1' 5' 10' 15'1'

1/4"=1'-0"

DATA OUTLET MOUNTED ON COUNTERTOP.

PROVIDE A 2" EMPTY CONDUIT FOR CATV PROVIDER AND

ROUTE CONDUIT STUB 5'-0" OUTSIDE OF BUILDING.

1.

2.

COMM

PBB

UNSECURE

RACK

TR1-R1

PANEL 'TPP1'

4" CONDUIT

SLEEVES INTO

COORIDOR

PET

110-TYPE PUNCH

DOWN BLOCKS AND

CROSS-CONNECTS

(STACK AS NEEDED)

4" SERVICE

ENTRANCE CONDUITS

CATV ENTRANCE

CONDUIT2 IDS PANEL

ACS PANEL

12" LADDER-TYPE

CABLE TRAY

0' 1'1' 1/2"=1'-0"

2' 3' 4' 5'

SEE SHEETS TN501 - TN503 FOR DETAILS AND DIAGRAMS.A.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:3

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TN101

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

V

IS

IT

O

R S

C O

N

TR

O L

C E

N

TE

R F

LO

O

R P

LA

N

TE

LE

C

O M

M U

N

IC

A

TI

O N

S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T N q tu c k e r

SCALE: 1/4" = 1'-0"

VISITORS CENTER FLOOR PLAN - TELECOMMUNICATIONS

PLAN

NORTH

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

SHEET KEYNOTES

SCALE: 1/2" = 1'-0"

ENLARGED COMM ROOM 116 - TELECOMMUNICATIONS

TN101

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881125 343 358

STOR/JAN

STORAGE

BREAKROOM

COMM

WAITING

INSPECTION

OFFICE

RFI/SECURE

ROOM

RESTROOM

MECH/ELEC

WALL MOUNTED

SERVER RACK

CORR

PANEL 'L3'

A

B C D E

PANEL 'G'

PANEL 'L4'

LOADCENTER 'B'

XFMR 'T2'

TN102

1C

FACP

IDS PANEL

1/8" = 1'-0"

0' 5' 10' 20' 30'

'CTB'

WALL MOUNTED

SERVER RACK

PANEL 'TPP2'

PBB

4" SERVICE ENTRANCE

CONDUITS

110-TYPE PUNCH

DOWN BLOCKS AND

CROSS-CONNECTS

(STACK AS NEEDED)

ACS PANEL

IDS PANEL

ROUTE CONDUIT TO HANDHOLE OUTSIDE OF BUILDING. SEE

SHEET TS102 FOR CONTINUATION.

MOUNT OUTLET 1'-0" BELOW THE CEILING FOR CCTV

MONITOR.

MOUNT OUTLETS 6'-0" AFF THE CEILING FOR CCTV MONITOR.

1.

2.

3.

SEE SHEETS TN501, TN502 AND TN503 FOR

TELECOMMUNICATIONS DETAILS.

A.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:0

:3

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tle r_

IS

T

E L E

R q tu c k e r@ jp h e s .c o m

.r v t

TN102

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IN

S

P E

C

TI

O N

S

TA

TI

O

N , P

O V

, A N

D C

V

IS

F

LO

O R

P

LA

N

TE

LE

C O

M M

U N

IC

A

TI

O

N S

JAWWQT WQT

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T N q tu c k e r

SCALE: 1/8" = 1'-0"

INSPECTION STATION, POV, AND CVIS FLOOR PLAN - TELECOMMUNICATIONS

PLAN

NORTH

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

SHEET KEYNOTES

SCALE: 1/2" = 1'-0"

INSPECTION STATION, POV, AND CVIS FLOOR PLAN - COMM 104

PLAN

NORTH

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881126 344 358

5-7/8" (MIN) -

35-7/16" (MAX)

TR1-1-1

BASKET CABLE TRAY

AS INDICATED

ON DRAWINGS

AS INDICATED

ON DRAWINGS

SUPPORT TRAY PER SPECIFICATIONS

AND MANUFACTURER'S RECOMMENDATIONS

INSULATED BUSHING

FINISHED CEILING

TYPICAL CONDUIT STUB-OUT. EXTEND CONDUIT

TO WITH-IN 5-7/8" OF CABLE TRAY AND GROUND

TO CABLE TRAY SYSTEM.

WALL PHONE

FACEPLATE WITH (2)

RJ-45 VOICE JACK

VOICE

TR1-1-1

A B

C D

SINGLE GANG

NOTE:

DATA JACKS NOT BEING UTILIZED ARE SPARES. SEE FLOOR

PLANS FOR AMOUNT OF DATA JACKS NEEDED AT EACH

LOCATION.

TR1-1-1

A B

C D

PATCH PANEL

NUMBER

STATION OUTLET

NUMBER

OUTLET PORT

(TYPICAL)

POLYAMIDE STANDOFF

INSULATOR

304 STAINLESS STEEL

BRACKET, 3MM THICK

FRONT VIEW

TOP VIEW

12"

4"

9"

1-1/8" TYP

1''

5/8"

5/8''

5/16" (15 PAIR)

7/16" (3 PAIR)

SPACE FOR GOVERNMENT

FURNISHED/INSTALLED

EQUIPMENT

FIBER OPTIC

PATCH PANEL

48 PORT CAT 6 PATCH

PANEL FOR VOICE/DATA WITH

K-110 TYPE PUNCHDOWN BLOCKS

48 PORT CAT 6 PATCH

PANEL FOR VOICE/DATA WITH

K-110 TYPE PUNCHDOWN BLOCKS

48 PORT CAT 6 PATCH

PANEL FOR VOICE/DATA WITH

K-110 TYPE PUNCHDOWN BLOCKS

VOICE PATCH PANEL

K-110 TYPE PUNCHDOWN BLOCKS

CABLE MANAGEMENT PROVIDED

ABOVE, BELOW, BETWEEN, AND

ON BOTH SIDES OF PATCH

PANELS TO INCLUDE FRONT

AND REAR OF RACK AND PATCH

PANEL ASSEMBLY (TYPICAL)

NOTE : WIRE MANAGEMENT

SHALL BE FINGER DUCT,

HINDGED TYPE.

18" UON

1" CONDUIT

SECURELY

MOUNTED

COMMUNICATIONS

OUTLET BOX AND

PLATE

6" ABOVE ACCESSIBLE CEILING

STUB-UP ABOVE CEILING

INTO CORRIDOR AND

PROVIDE BUSHING &

IDENTIFICATION.

WALL

CEILING

FINISHED FLOOR

CATEGORY 6 (CAT6)

OUTLET

CONNECTION

(TYPICAL)

CATEGORY 6 (CAT6) CABLE CONNECTION

NOT TO SCALE

TYPICAL CABLE TRAY DETAIL

NOT TO SCALE

TYPICAL TELECOMMUNICATIONS JACK DETAIL -

CATEGORY 6 (CAT6) CABLE CONNECTION

NOT TO SCALE

TELECOMMUNICATIONS VOICE JACK DETAIL -

NOT TO SCALE

TYPICAL TELECOMMUNICATIONS

JACK LABEL DETAIL

NOT TO SCALE

TYPICAL TELECOMMUNICATIONS PRIMARY

BONDING BUSBAR (PBB) DETAIL

TYPICAL SERVER RACK DETAIL

NOT TO SCALE

NOT TO SCALE

TYPICAL COMMUNICATIONS OUTLET

CONDUIT RISER DIAGRAM

TELECOMMUNICATIONS

ROOM NUMBER

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:4

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TN501

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

TE

LE

C O

M M

U N

IC

A

TI

O

N S

D E

TA

IL

S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T N q tu c k e r

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881127 345 358

CTB COMMUNICATIONS TERMINAL BACKBOARD

GROUNDING ELECTRODE CONDUCTORGEC

BCT

ACEG

BONDING CONDUCTOR FOR TELECOMMUNICATIONS

ALTERNATING CURRENT EQUIPMENT GROUND

TELECOMMUNICATIONS PRIMARY

BONDING

BUSBAR

PBB

ABBREVIATIONS

PBB

IT/COMM

ROOM

ELECTRICAL

ROOM

BUILDING STEEL

BCT

CTB

ACEG

GROUNDING

CONDUCTOR TO STEEL

GEC

PANEL TPP1PANEL L1

TELECOMMUNICATIONS GROUNDING DETAIL - VISITORS CENTER

NOT TO SCALE

PBB

IT/COMM

ROOM

ELECTRICAL

ROOM

BUILDING STEEL

BCT

CTB

ACEG

GROUNDING

CONDUCTOR TO STEEL

GEC

PANEL TPP2PANEL L3

TELECOMMUNICATIONS GROUNDING DETAIL - INSPECTION STATION

NOT TO SCALE

EXISTING GROUNDING

GRID BARE COPPER

DISCONNECT AND

REMOVE EXISTING

GROUNDING CABLE IN

AREA OF WORK

EXOTHERMIC WELDS

EXISTING GROUNDING

GRID BARE COPPER

EXOTHERMIC WELDS (TYP)

INSTALL NEW BARE COPPER

GROUND CABLE (MATCH EXISTING)

CONNECT NEW GROUNDING

WIRES TO EXISTING WIRES WITH

EXOTHERMIC WELDS

CONNECT NEW

GROUNDING WIRES TO

MATCH EXISTING GRID

PATTERN WITH

EXOTHERMIC WELDS

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:4

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TN502

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

TE

LE

C O

M M

U N

IC

A

TI

O

N S

D E

T A

IL

S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T N q tu c k e r

NOT TO SCALE

EXISTING GROUNDING GRID DETAIL

NOT TO SCALE

REPLACEMENT GROUNDING GRID DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881128 346 358

COMM

ROOM

PRIMARY BONDING

BUSBAR (PBB)

#6 COPPER GND

CABLE TYPE LADDER

(2) DUPLEX RECEPTACLES MOUNTED

ON

EACH COMMUNICATIONS TERMINAL

BACKBOARD

SINGLE MODE FIBER OPTIC

COMBINATION DISTRIBUTION/PATCH

PANEL (BACKBONE), 4 RU, 96 PORTS,

TYPE SC CONNECTORS

CABLE MANAGEMENT

PROVIDED

ABOVE, BELOW, BETWEEN, AND

ON BOTH SIDES OF PATCH

PANELS TO INCLUDE FRONT

AND REAR OF RACK AND PATCH

PANEL ASSEMBLY (TYPICAL)

CAT6 CABLES PUNCHED DOWN AT

PATCH PANEL ON 110 TYPE BLOCK

(SUPPORTED BY LADDER

RACK ,TYP)

#6 COPPER

GROUND ACEG

TO

PBB

PANEL 'TPP1'

CEILING SPACE

CABLE TRAY

RACK SPACE FOR

GOVERNMENT

ELECTRONIC

NETWORK

EQUIPMENT

(TYPICAL)

96-STRANDS OF SMFOC INCOMING SERVICE

CABLE FROM BUILDING 100, 12-STRANDS SMFOC

TO INSPECTION STATION

NOTES:

1. PROVIDE PROPER CABLE MANAGEMENT IN

TELECOMMUNICATIONS RACKS (NOT

DEPICTED IN THIS DIAGRAM)

2. LOCATION OF EQUIPMENT, CABLES, AND

CONDUITS ARE DIAGRAMMATIC. REFER TO

TELECOMMUNICATIONS DRAWINGS FOR

PLACEMENT OF EQUIPMENT.

3. PROVIDE 4" ENTRANCE CONDUITS WITH

FIRESTOP.

4. FIBER OPTIC BACKBONE PATCH PANEL

CONNECTORS SHALL BE "SC" TYPE IN

ACCORDANCE WITH I3A.

#4 COPPER GROUND TO BUILDING

GROUNDING COUNTERPOISE

DOUBLE DUPLEX RECEPTACLE

MOUNTED ON EQUIPMENT

RACK

(TYPICAL)

HORIZONTAL VOICE PATCH PANEL,

CAT6 RATED 8-PIN MOD

CONNECTOR

CABLE

MANAGEMENT

RINGS (TYPICAL)

PROTECTIVE ENTRANCE

TERMINALS (PET)

110 TYPE BLOCKS

CROSS-CONNECT

TIE CABLE FROM

PET TO 110

BLOCKS

VOICE

PATCH

110 TYPE

BLOCKS

FIBER MAINTENANCE

LOOP WITH MINIMUM

LENGTH OF 25'-0".

50 PAIR PE89 COPPER INCOMING SERVICE

SMFOC BACKBONE CABLE, 50'-0"

MAXIMUM WITH OSP SHEATH IN

MINIMUM 1" MESH INNERDUCT.

4" SERVICE ENTRANCE CONDUITS

#6 COPPER GND

COMMUNICATIONS

TERMINAL BACKBOARD

(CTB)

#4 COPPER

PRIMARY BONDING

CONDUCTOR (PBC)

TO PANEL 'L1'

2" CATV SERVICE ENTRANCE CONDUIT

COMM

ROOM

PRIMARY BONDING

BUSBAR (PBB)

#6 COPPER GND

CABLE TYPE LADDER

(2) DUPLEX RECEPTACLES MOUNTED

ON

EACH COMMUNICATIONS TERMINAL

BACKBOARD

SINGLE MODE FIBER OPTIC

COMBINATION DISTRIBUTION/PATCH

PANEL (BACKBONE), 4 RU, 24 PORTS,

TYPE SC CONNECTORS

CABLE MANAGEMENT

PROVIDED

ABOVE, BELOW, BETWEEN, AND

ON BOTH SIDES OF PATCH

PANELS TO INCLUDE FRONT

AND REAR OF RACK AND PATCH

PANEL ASSEMBLY (TYPICAL)

CAT6 CABLES PUNCHED DOWN AT

PATCH PANEL ON 110 TYPE BLOCK

(SUPPORTED BY LADDER

RACK ,TYP)

#6 COPPER

GROUND ACEG

TO

PBB

PANEL 'TPP2'

CEILING SPACE

RACK SPACE FOR

GOVERNMENT

ELECTRONIC

NETWORK EQUIPMENT

(TYPICAL)

24-STRANDS OF SMFOC INCOMING SERVICE

CABLE FROM BUILDING 129

NOTES:

1. PROVIDE PROPER CABLE MANAGEMENT IN

TELECOMMUNICATIONS RACKS (NOT

DEPICTED IN THIS DIAGRAM)

2. LOCATION OF EQUIPMENT, CABLES, AND

CONDUITS ARE DIAGRAMMATIC. REFER TO

TELECOMMUNICATIONS DRAWINGS FOR

PLACEMENT OF EQUIPMENT.

3. PROVIDE 4" ENTRANCE CONDUITS WITH

FIRESTOP.

4. FIBER OPTIC BACKBONE PATCH PANEL

CONNECTORS SHALL BE "SC" TYPE IN

ACCORDANCE WITH I3A.

#2 COPPER GROUND TO BUILDING

GROUNDING COUNTERPOISE

DOUBLE DUPLEX RECEPTACLE

MOUNTED ON EQUIPMENT

RACK

(TYPICAL)

HORIZONTAL VOICE PATCH PANEL,

CAT6 RATED 8-PIN MOD

CONNECTOR

CABLE

MANAGEMENT

RINGS (TYPICAL)

PROTECTIVE ENTRANCE

TERMINALS (PET)

110 TYPE BLOCKS

CROSS-CONNECT

TIE CABLE FROM

PET TO 110

BLOCKS

VOICE

PATCH

110 TYPE

BLOCKS

FIBER MAINTENANCE

LOOP WITH MINIMUM

LENGTH OF 25'-0".

12 PAIR PE89 COPPER INCOMING SERVICE

SMFOC BACKBONE CABLE, 50'-0"

MAXIMUM WITH OSP SHEATH IN

MINIMUM 1" MESH INNERDUCT.

4" SERVICE ENTRANCE CONDUITS

#6 COPPER GND

COMMUNICATIONS

TERMINAL BACKBOARD

(CTB)

#4 COPPER

PRIMARY BONDING

CONDUCTOR (PBC)

TO PANEL 'L1'

2" CATV SERVICE ENTRANCE CONDUIT

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:5

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TN503

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

TE

LE

C O

M M

U N

IC

A

TI

O

N S

V O

IC

E

A N

D D

A T

A B

A C

K B

O N

E E

LE

V

A

TI

O N

D E

TA

IL

S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T N q tu c k e r NOT TO SCALE

TELECOMMUNICATIONS VOICE AND DATA ELEVATION DETAIL - VISITORS CONTROL CENTER BUILDING

NOT TO SCALE

TELECOMMUNICATIONS VOICE AND DATA ELEVATION DETAIL - INSPECTION STATION, POV, AND CVIS BUILDING

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881129 347 358

BMS

AK

DA

NVR

IDS

PoE

M

BALANCED MAGNETIC SWITCH (HSS UL LEVEL 2).

STATIONARY CCTV CAMERA. PROVIDE A 1" CONDUIT .

ARM/DISARM ALARM KEYPAD.

DURESS ALARM MOUNTED UNDERNEATH DESK.

NETWORK VIDEO RECORDER (NVR). MOUNTED IN SERVER RACK.

INTRUSION DETECTION SYSTEM (IDS).

POWER OVER ETHERNET (PoE) NETWORK SWITCH

MOUNTED IN

SERVER RACK.

PAN-TILT-ZOOM (PTZ) CCTV CAMERA. PROVIDE A 1"

CONDUIT TO LOCATION.

CCTV MONITOR

LICENSE PLATE RECOGNITION (LPR) CAMERA.

MOTORIZED GATE OPERATOR CONTROLS.

ACTIVE VEHICLE BARRIER CONTROLS.

A1

TN401

TELECOMMUNICATIONS SERVER RACK.

SHEET LOCATION

SHEET

NUMBE

R

ENLARGED REFERNCELEGEND AND ABBREVIATIONS

S

C

L

EL ELECTRONIC DOOR LOCK.

P EMERGENCY RED PUSH BUTTON. MOUNT 48" AFF, UON.

100A DOOR DESIGNATION.

BASKET-TYPE CABLE TRAY, SIZE AS INDICATED.

CABLE LADDER, SIZE AS INDICATED.

TELECOMMUNICATIONS SERVER RACK, WALL MOUNTED.

CR CARD READER.

X10 X-10 HIGH SECURITY COMBINATION LOCK.

CC

ACCESS CONTROL PEDESTAL. SEE DRAWINGS FOR

LIST OF DEVICES TO BE MOUNTED.

MD MOTION DETECTOR.

FENCE DETECTION SYSTEM MOUNTED IN SERVER

RACK.

FDS

RADAR DETECTION EQUIPMENT.R

TRAFFIC LANE LIGHT. CONTROLLED FROM AVB MASTER

CONTROLLER IN INSPECTION STATION BUILDING.

GS GLASS BREAK SENSOR.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:5

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TY001

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

E

LE

C

TR

O N

IC

S

E C

U R

IT

Y

S Y

S

TE

M

E S

S

LE

G

E N

D , N

O

TE

S , A

N D

A B

B R

E V

IA

TI

O N

S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T Y q tu c k e r

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881130 348 358

R E

F

FACP

X10

X10

CR

BMSEL

C R

B M

S E

L

CR BMS

EL

CR

EL

BMS

B M

S

CR

E L

BMS

CR

EL

CR

BMSEL

C R

B M

S E

L B

M S

BMS

C

C

DA

DA

DA

DA DA

M

MD

NVR

AK

FDS

A K

C

C

C

CREL

BMS CR

MECH/ELEC

VESTIBULE

TOILET

MUD ROOM

COMM

WAITING

OFFICE

INTERVIEW

OFFICE

MOTHER'S

SHOWER

ADMIN/COPY

SIPRNET

EXIST

BREAKROOM

PANEL 'MDP'

'ATS'

'CTB' (TYPICAL)

PANEL 'TPP1'

102A

E103

E101

EXTERIOR WALL

MOUNTED CCTV

CAMERA (TYPICAL)

SECURE

SERVER

CABINET

102B

108B

TOILET

LAUNDRY

HALLWAY

HALLWAY

ID/CHECK-IN

DAYROOM

117B

SERVICE

DISCONNECT

XFMR 'T1'

CEILING MOUNTED

CCTV CAMERA

(TYPICAL)

ROOF OUTLINE

PROVIDE BECON LIGHT MOUNTED TO FACE OF

BUILDING WITH CLEAR LINE OF SIGHT TO THE

ENTRY CONTROL POINT. BECON SHALL BE

INTERLOCKED WITH THE DURESS ALARM

SYSTEM.

IDS PANEL

ACS PANEL

IDS PANEL

PANEL 'L1'

PANEL 'L2'

ACS PANEL

LOCKER ROOM

CCTV CAMERA

MOUNTED ON

CANOPY CEILING

(TYPICAL)

90.00°

90.00°

90.00°

90.00°

90.00°

90.00°

CCTV CAMERA

FIELD OF VIEW

(TYPICAL)

0' 1' 5' 10' 15'1'

1/4"=1'-0"

ACCESS CONTROL AND INTRUSION DETECTION SYSTEM

FOR THIS SPACE MUST BE STAND-ALONE.

PROVIDE CARD READER WITH KEYPAD.

1.

2.

SEE SHEETS TY501 THROUGH TY507 FOR SECURITY DETAILS

AND DIAGRAMS.

FIELDS OF VIEW ARE SHOWN CONCEPTUALLY. SECURITY

CONTRACTOR MUST COORDINATE OPTIMAL AIMING ANGLES

BASED ON SITE CONDITIONS FOR MAXIMUM COVERAGE.

A.

B.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:0

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TY101

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

V

IS

IT

O

R S

C O

N

TR

O L

C E

N

TE

R F

LO

O

R P

LA

N

E

LE

C

TR

O

N

IC

S E

C U

R

IT

Y S

Y S

TE

M

E

S S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T Y q tu c k e r

SCALE: 1/4" = 1'-0"

VISITORS CENTER FLOOR PLAN - ELECTRONIC SECURITY SYSTEM (ESS)

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

SHEET KEYNOTES

PLAN

NORTH

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881131 349 358

BMS

EL

CR

B M

S

C R

E L

X

CR

BMS

EL

B M

S

C R

E L

CR

BMS

EL

B M

S E

L

C R

C

C C

C

C

BMS

CR

EL

G

BMS

M

D A

D A D

A

MD

S L

L

DA

MD

A

P

P D

A

L

AK

AK

M

EL

GS

S S S

S

S

STOR/JAN

CORR

BREAKROOM

WAITING

INSPECTION

OFFICE

RFI/SECURE

ROOM

RESTROOM

MECH/ELEC

'CTB'

WALL MOUNTED

SERVER RACK

101B

101A

101C

PBB

A

B C D E

PANEL 'G'

PANEL 'L3'

PANEL 'L4'

STORAGE

LOADCENTER 'B'

AVB/DROP ARM

MASTER

CONTROLLER

PANEL 'L5'

ACS PANEL

IDS PANEL

IDS PANEL

42" CCTV MONITOR

42" CCTV MONITOR42" CCTV MONITOR

42" CCTV MONITOR

42" CCTV MONITOR

COMM

3 3

CCTV CAMERA

FIELD OF VIEW

(TYPICAL)

6 6

7 TYPICAL7 TYPICAL

3/16" = 1'-0"

0'5' 5' 10'

SEE SHEETS TY501 THROUGH TY507 FOR SECURITY DETAILS

AND DIAGRAMS.

FIELDS OF VIEW ARE SHOWN CONCEPTUALLY. SECURITY

CONTRACTOR MUST COORDINATE OPTIMAL AIMING ANGLES

BASED ON SITE CONDITIONS FOR MAXIMUM COVERAGE.

CCTV CAMERAS ON THIS PLAN MUST BE MONITORED AND

CONTROLLED FROM THE INSPECTION STATION. SEE SHEET

TY101 FOR LOCATION OF NETWORK VIDEO RECORDER (NVR)

IN VISITORS CONTROL CENTER.

A.

B.

C.

ACCESS CONTROL AND INTRUSION DETECTION SYSTEM

FOR THIS SPACE MUST BE STAND-ALONE.

PROVIDE CARD READER WITH KEYPAD.

PROVIDE TRAFFIC LANE LIGHT AND ROUTE CONTROL

CABLING BACK TO AVB MASTER CONTROLLER.

MOUNT CCTV MONITOR HIGH TO BE OVER INSPECTION

OFFICE WINDOWS AND TO MINIMIZE LINE OF SIGHT TO

AREA AROUND INSPECTION STATION.

MOUNT CCTV MONITOR 4'-6" AFF TO THE BOTTOM OF THE

MONITOR.

MOUNT CCTV CAMERA 12'-0" AFF.

MOUNT CCTV CAMERA TO CANOPY CEILING.

1.

2.

3.

4.

5.

6.

7.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:0

:4

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tle r_

IS

T

E L E

R q tu c k e r@ jp h e s .c o m

.r v t

TY102

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IN

S

P E

C

TI

O N

S

TA

TI

O

N , P

O V

, A N

D C

V

IS

F

LO

O R

P

LA

N

E

LE

C

TR

O N

IC

S

E C

U R

IT

Y

S Y

S

TE

M

E S

S

JAWWQT WQT

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T Y q tu c k e r

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

SHEET KEYNOTES

SCALE: 3/16" = 1'-0"

INSPECTION STATION FLOOR PLAN ELECTRONIC SECURITY SYSTEM (ESS)

PLAN

NORTH

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881132 350 358

A

B

C

D

E

F

G

4 CONDUCTOR 22AWG SHIELDED PLENUM

2 CONDUCTOR 22AWG SHIELDED PLENUM

6 CONDUCTOR 22AWG TWISTED SHIELDED PLENUM

2 CONDUCTOR 18AWG SHIELDED PLENUM

4 CONDUCTOR 20AWG SHIELDED PLENUM

4 CONDUCTOR 22AWG SHIELDED PLENUM

4 PAIR 22AWG CAT6e SHIELDED PLENUM

REX DEVICE POWER AND STATUS AND OTHER USE

DOOR CONTACT STATUS OR OTHER USE

READER DATA WIEGAND

LOCK CONTROL AND/OR OTHER USES

RS-485 COMMUNICATION

INTRUSION DEVICES

ETHERNET LAN DATA UP TO 2.5GBIT/S

CABLE LEGEND

CABLE ID DESCRIPTION USED FOR

DABMS

RJB

BMSBMS

RJB

DA

RJB

BMSCR EL

RJB

BMSCR EL

102 107101 108 116 119104 106

RM

RM

RM

NOT TO SCALE

VISITOR CENTER ACCESS & INTRUSION WIRING DIAGRAM

RM

RM

RM

RM

RM

RM

RM

ACS

APS

IDS

EXP

SYSTEM

LOCATION

TO LAN

120 VAC120 VAC

TO LAN

A,B

B

B

B B

B B

A,B,E,F

C

C

A,B,E,F

F B E

B

A,B,E,F

F B E

B

CR

F

EL

E

CR EL

F E

DA

C

BMSCR BMS EL

RJB

B B

A,B,E,F

F B EB

RJB

BMSCR EL

A,B,E,F

F B E

B

RM

DA

C

DA

CRJB

BMSCR EL

RM

A,B,E,F

F B E

B

RJB

BMSCR EL

A,B,E,F

F B E

B

CR

F

BMSBMS

RJB RJB

BMSCR EL

101 104

NOT TO SCALE

INSPECTION STATION ACCESS & INTRUSION WIRING DIAGRAM

RM

RM

RM

ACS

APS

IDS

EXP

SYSTEM

LOCATION

TO LAN

120 VAC120 VAC

TO LAN

B B

B B

A,B,E,F A,B,E,F

F B E

B

CR

F

EL

E

CR EL

F E

BMSCR BMS EL

RJB

B B

A,B,E,F

F B EB

RJB

BMSCR EL

RM

A,B,E,F

F B E

B

DA

C

BMS

B

B

CR EL

F E

BMS

B

B

CR EL

F E

DA

C

X10AK BMS EL

RJB

B B

A,B,E,F

F E EB

IDS

SYSTEM

LOCATION

TO LAN

120 VAC120 VAC

TO LAN

ACS

APS

NOT TO SCALE

ACCESS & INTRUSION WIRING DIAGRAM - SECURE ROOMS

WIRING DIAGRAMS SHOWN ARE CONCEPTUAL. SECURITY

CONTRACTOR MUST COORDINATE WIRING TERMINATIONS

PER MANUFACTURER'S RECOMMENDATIONS.

A.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:1

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TY501

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

S E

C U

R

IT

Y D

IA

G

R A

M S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T Y q tu c k e r

GENERAL SHEET NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881133 351 358

B

42"

12"

84"

A

3.81

10.44 8.13

3.32

DETAIL A

.28

3.81

7"

7"

DETAIL B

NOTES:

1. 1/2"ø MOUNTING HARDWARE IS RECOMMENDED FOR

5X5 BASE PLATES. L-BOLT-500,STUD-ANCHOR-500.

2. 5/8"ø MOUNTING HARDWARE RECOMMENDED FOR 8X8

BASE PLATES. L-BOLT-625,STUD-ANCHOR-625.

HIGH/LOW ACCESS CONTROL PEDESTAL DETAIL

NOT TO SCALE

BMS

BMS

BMS

BMS

BMS

BMS

BMS

BMS

BMS

1B

(TYPICAL OF 10)1C

120V

ALARM KEYPAD

INTRUSION SYSTEMS PANEL AND DEVICE WIRING DIAGRAM - VISITORS CENTER

NOT TO SCALE

IDS-01-01

119BMS

1C

ALARM KEYPAD

VESTIBULE 101

COMM 116

BMS

BMS

BMS

BMS

BMS

BMS

BMS

1B

(TYPICAL OF 7)

1C

120V

ALARM KEYPAD

INTRUSION SYSTEMS PANEL AND DEVICE WIRING DIAGRAM - INSPECTION STATION

NOT TO SCALE

IDS-02-01

COMM 104

CEILING

MAGNETIC CONTACT

(DOOR MONITOR)

HINGE

LEVER HANDLE MORTISE

LOCK (PANIC BAR FOR DOORS

WITHOUT LEVER HANDLE)

FINISHED FLOOR

SECURITY

CONTROL PANEL

1/2" CONDUIT

CARD READER

UNSECURE SIDE

48" AFF

1" CONDUIT BACK TO

SECURITY PANEL

1" CONDUIT

CONTINUATION

TO NEXT DOOR

BALANCED MAGNETIC CONTACT, ELECTRIFIED HINGE, LEVER

HANDLE MORTISE LOCK (OR PANIC BAR WHERE REQUIRED), AND

CARD READER, REQUEST TO EXIT PUSH BUTTON (ONLY IN SECURE

AREAS)

1/2" CONDUIT

4x4 JUNCTION BOX

ELECTRIFIED

LOCK

HINGE

PUSH TO EXIT

SECURE SIDE

(SECURE

ROOMS ONLY)

NOTE:

DETAILS SHOWN ARE CONCEPTUAL. CONTRACTOR

MUST COORDINATE WITH THE SELECTED VENDOR

FOR INSTALLATION REQUIREMENTS.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

03/09/2023

/8

/2

:1

:1

P M

C U s e rs

\q tu c k e r.

J P

H A

R V

E Y

\D o c u m e n ts

W

P

C u tl e r_

V C

T

E L

E

R q tu c k e r@ jp h e s .c o m

.r v t

TY502

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

S E

C U

R

IT

Y D

IA

G

R A

M S

A N

D D

E

TA

IL

S

JAWWQT WQT

02/08/2023

Approved by Jeffrey Hoyt, PWD ME, via Email

IM

P

R O

V E

M E

N

TS

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

JAS

DSN

M

ID

L A

N T

D C

C O

R E

T Y q tu c k e r

NOT TO SCALE

SECURITY DOOR DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

12881134 352 358

ETHERNET AND POWER TO RADAR

AC POWER (115/230 VAC 3 A)

ETHERNET/FIBER OPTIC CABLE TO RADAR SERVER

LEVELING PLATE

BREAKOUTBOX CONTAINS:

1) POWER SUPPLY FOR RADAR

2) ETHERNET TO RADAR (MEDIA CONVERTER DO FIBER TRANSMISSION - OPTIONAL)

3) POWER SUPPLY FOR MEDIA CONVERTER (IF DIFFERENT THAN RADAR POWER SUPPLY).

NOTE: CONNECT THE CABLE SHIELD TO A PROTECTIVE EARTH (GROUND) CONNECTION.

POLE DETAILS:

RIGIDITY IS IMPORTANT TO RADAR PERFORMANCE, SO A VERY STIFF POLE IS REQUIRED.

HEIGHT IS SITE-DEPENDENT AND WILL BE DETERMINED DURING THE SITE SURVEY FOR

EACH LOCATION. 6-30 FEET IS TYPICAL TO BASE OF RADAR.

NOTES:

1) COORDINATE FINAL REQUIREMENTS FOR MOUNTING OF RADAR EQUIPMENT WITH

SELECTED VENDOR.

2) SEE SHEET EY505 FOR SECURITY EQUIPMENT PAD DETAILS, POLE DETAIL, AND ANCHOR

BASE FOUNDATION DETAIL.

TYPICAL RADAR EQUIPMENT FEATURES AND SPECIFICATIONS

RADAR ASSEMBLY

RADAR TO PROVIDE DETECTION CAPABILITY FOR MOVING OBJECTS ON THE GROUND OVER AN

AREA OF UP TO 360° AND PRESENTS DETECTION DATA TO THE OPERATOR THROUGH A GRAPHICAL USER INTERFACE (GUI). THE DATA TRANSMITTED VIA VENDOR'S SOFTWARE APPLICATION USING AN EXTENSIBLE MARKUP LANGUAGE (XML) CLIENT RESPONSIBLE FOR COORDINATING & IMPLEMENTING SECURITY POLICIES.

RADAR RANGE OF SPECIFICATIONS (VENDOR TO COORDINATE WITH

EXISTING SITE CONDITIONS)

WEIGHT

COOLING

OPERATING

TEMPERATURE RANGE

OPERATING

ALTITUDE RANGE

POWER INPUT

FREQUENCY BAND

INSTRUMENTED RANGE

WARM-UP TIME

SCAN RATE

ENVIRONMENTAL

WIND

RADIATED POWER

13.2 KG - 17KG

NO FORCED COOLING REQUIRED

-30 DEGREE CELSIUS TO +60 DEGREE CELSIUS

UP TO 15,000 FT. / 4,572 M.

20-32 VDC (NOMINAL 24 VDC). LESS THAN 45 W

KA

5M - 10000 M; VENDOR COORDINATED WITH SITE CONDITIONS

READY TO OPERATE APPOXIMATELY 1 MINUTE AFTER POWER-UP

UP TO 55 SCANS/MINUTE

NEMA 4, IP65

140 KM/HR

SAFE FOR HUMAN EXPOSURE

NOTE:

DETAILS SHOWN ARE CONCEPTUAL.

CONTRACTOR MUST COORDINATE WITH

THE SELECTED VENDOR FOR

INSTALLATION REQUIREMENTS.

MID-RANGE PERIMETER SURVEILLANCE RADARS

GENERAL SPECIFICATIONS

TARGET TYPES

TARGET VELOCITY

SCAN RATE

AZIMUTH BEAMWIDTH

INPUT POWER

RADIATED POWER

COMMUNICATIONS

XML

FALSE ALARM RATES

FREQUENCY

RESOLUTION

ELEVATION BEAMWIDTH

ELEVATION CONTROL

MASK ZONES(S)

NETWORK

DIMENSIONS

WEIGHT

MOVING, GREATER THAN 0.1 M/S MINIMUM

VEHICLES AND PERSONNEL

0.1 TO 50 M/S

ONE REVOLUTION PER SECOND (60 RPM)

1 DEGREE (2-WAY)

20 TO 32 VDC, 24 NOMINAL

SAFE FOR HUMAN EXPOSURE

ETHERNET OR FIBER

YES

< 1 PER 24 HOURS

KA BAND

0.3 M RANGE, 1 DEGREE AZIMUTH

6 DEGREE (2-WAY)

UP: 2 DEGREE; DOWN: 10 DEGREE (FIXED SETTINGS)

TWO SELECTABLE ANGULAR BLANK SECTORS

UNLIMITED POLYGON DETECTION ZONES

8 PER SERVER; TOTAL UNLIMITED

13" H X 17" DIAMETER

24 LBS (11 KG)

ENVIRONMENTAL

TEMPERATURE -30 DEGREE TO +60 DEGREE CELSUIS (OPERATING)

-40 DEGREE TO +70 DEGREE CELSUIS (STORAGE)

HUMIDITY 50% +/- 5 TO 95% +/- 4,

NON-CONDENSING (60 DEGREE CELSUIS MAX)

ALTITUDE UP TO 15,000 FT (OPERATING AND

STORAGE)

VIBRATION MIL-STD-810F

SHOCK 40 G PEAK FO 20 MS, HALF SINE

(WITH VIBRATION MOUNT)

WIND UP TP 120 KM/HR

WEATHER SEALING WEATHER RESISTANT (RAIN,

SNOW, DUST, SAND, SALT SPRAY)

POWER CONSUMPTION 45 WATTS

RATINGS FCC CLASS B, EN 301480, PARTS 1& 3;

CE: EN 60215 EN 300019-1-4

(CLASS 4.1E WITH -40 DEGREE CELSUIS)

EN 300019-1-5 (CLASS 5.2, INCLUDING

MECHANICAL CLASS 5M3)

ENVIROMENTAL RATINGS NEMA 4

DATA BANDWIDTH MAXIMUM: 1 MBITS WITHOUT PPI

MAXIMUM: 7 MBITS WITH PPI

PROTOCOL ICD 0100

SATISFACTORY TO DATE

APPROVED

ACTIV…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .