1614700dwg01of22GENERAL.pdf

PDF 42 MB Posted

Attached to
P347 Perimeter Security Improvement, Portsmouth Naval Shipyard, NCTS Cutler, Maine
Solicitation number
N4008523R2539
Issued by

View the file

Other files

File Type Posted
Amendment 0012.pdf PDF
P-347 Price Proposal Form AMD 0012.pdf PDF
1614700Amend0011dwg.pdf PDF
P347 AMENDMENT 0011.pdf PDF
1614700Amend0011spc.pdf PDF
Prospect Harbor Canopy Drawings Calcs Data.pdf PDF
P347 AMENDMENT 0010.pdf PDF
P347 AMENDMENT 0009.pdf PDF
P347 J-A Interior Finishes Redacted.pdf PDF
1614700Amend0008spc.pdf PDF
P347 AMENDMENT 0008.pdf PDF
1614700Amend0008dwg.pdf PDF
P347 AMENDMENT 0007.pdf PDF
P347 AMENDMENT 0006.pdf PDF
09 26 00.pdf PDF
Uline IH-2769-SPFR.PDF PDF
08 14 00.pdf PDF
Uline IH-1119-SPFR.PDF PDF
P347 AMENDMENT 0005.pdf PDF
CS507 - FENCING DETAILS.pdf PDF
P347 AMENDMENT 0004.pdf PDF
1614700dwg08of22CIVIL_SIGNING_UTILITIES.pdf PDF
1614700dwg18of22FIRE.pdf PDF
1614700dwg04of22CIVIL_ALIGNMENT_DEMO.pdf PDF
1614700dwg14of22LANDSCAPING.pdf PDF
1614700dwg21of22ELECTRICAL.pdf PDF
1614700dwg15of22ENVIRONMENTAL.pdf PDF
1614700dwg10of22CIVIL_EROSION_02.pdf PDF
1614700dwg13of22WETLAND.pdf PDF
1614700dwg12of22CIVIL_EROSION_04.pdf PDF
1614700dwg11of22CIVIL_EROSION_03.pdf PDF
1614700spc1of1.pdf PDF
1614700dwg17of22ARCHITECTURAL_INTERIOR.pdf PDF
1614700dwg05of22CIVIL_SITE.pdf PDF
1614700dwg20of22MECHANICAL.pdf PDF
1614700dwg03of22EXISTING_CONDITION.pdf PDF
1614700dwg02of22HAZMAT_GEOTECH.pdf PDF
1614700dwg19of22PLUMBING.pdf PDF
1614700dwg09of22CIVIL_EROSION_01.pdf PDF
1614700dwg22of22TELECOM_SECURITY_AUDIO.pdf PDF
1614700dwg07of22CIVIL_GRADING_DRAINAGE_02.pdf PDF
1614700dwg06of22CIVIL_GRADING_DRAINAGE_01.pdf PDF
1614700dwg16of22STRUCTURAL.pdf PDF
P347 AMENDMENT 0003.pdf PDF
P347 AMENDMENT 0002.pdf PDF
P347 AMENDMENT 0001.pdf PDF
Cutler Site Access Requirements-NAVFAC Instructions.docx DOCX document
N4008523R2539 P347 AMENDMENT 01.pdf PDF
Cutler Site Access Requirements-Contractor Instructions.docx DOCX document
SECNAV_5512_1_dtd_May21.pdf PDF
Show 40 more

Latest 50 of 105 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

A/E INFO

N

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D M

ID

A

T L

A N

T

IC

DRAWFORM REVISION: 25 AUGUST 2020

SCALE:

EPROJECT NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

1614700

CRH/LAF

IM

P

R O

V E

M E

N T S

P -3

P

E R

IM

E T

E R S

E C

U R

IT

Y

EJA

DSN

F

IL

E

M E p w g f n e t p w .b e n t le y .c o m :g f n e t p w

D o c u m e n t s

P r o je c t s

C A

D D

P L

S H

E E

T S

G F

P

G

.d g n

L

Y O

U T

M E

P lo t

P

O T T E

D

:1

M

E R jk n ig h t

AS NOTED

D E

P A

R T

M E

N T O

F T

H E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D

M

ID

L A

N T D

C C

O R

E N

A V

A L S

T A

T

IO

N -N

O R

F O

L K

V A

C U

T L E

R

M A

IN

E

N40085-19-D-9008 T008

02/08/23

PWD ME, via Email Approved by Jeffrey Hoyt, SEAL

DLB

SCALE: 1" = 200'

LOCATION MAP - ECF

CUTLER, ME

LOCATION MAP - OVERALL SITE

SCALE: 1" = 4000'

C O

V

R

E E

T

JSK JSK TCW

G-001

SUBMISSION: FINAL DESIGN

P-347 PERIMETER SECURITY IMPROVEMENTS

1 358

12880783

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D M

ID

A

T L

A N

T

IC

DRAWFORM REVISION: 25 AUGUST 2020

SCALE:

EPROJECT NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

1614700

CRH/LAF

IM

P

R O

V E

M E

N T S

P -3

P

E R

IM

E T

E R S

E C

U R

IT

Y

EJA

DSN

F

M E p w g f n e t p w .b e n t le y .c o m :g f n e t p w

D o c u m e n t s

P r o je c t s

C A

D D

P L

E E

T S

G F

P

G

.d

Y O

M E

P

O T T E

D

:0

:3

E R jk n ig h t

AS NOTED

D E

P A

R T

M E

N T O

F T

H E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D

M

ID

L A

N T D

C C

O R

E N

A V

A L S

T A

T

IO

N -N

O R

F O

L K

V A

C U

T L E

R

M A

IN

E

N40085-19-D-9008 T008

02/08/23

PWD ME, via Email Approved by Jeffrey Hoyt, SEAL

DLB

S H

E E

T

IN

D E

X

P-347 SHEET INDEX

JSK JSK TCW

G-002

NAMENO. NO. NAME TITLE

NO. NAME TITLE

CS303

CS302

CS301

CS202

CS201

CS111

CS110

CS109

CS108

CS107

CS106

CS105

CS104

CS103

CS102

CS101

CS100

CS001

CD104

CD103

CD102

CD101

CD100

CD001

CA601

CA600

CA111

CA110

CA109

CA108

CA107

CA106

CA105

CA104

CA103

CA102

CA101

CA100

C-001

VF112

VF111

VF110

VF109

VF108

VF107

VF106

VF105

VF104

VF103

VF102

VF101

VF100

V-001

B-600

B-502

B-501

B-500

B-201

B-100

H-102

H-101

GC500

GC109

GC108

GC107

GC106

GC105

GC104

GC103

GC102

GC101

GC100

GC002

GC001

GI102

GI101

GI003

GI002

GI001

G-004

G-003

G-002

G-001

TITLENAVFAC NO. NAVFAC NO. NAVFAC NO.

TYPICAL SECTIONS

TYPICAL SECTIONS

TYPICAL SECTIONS

PROFILE

PROFILE

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

SITE LAYOUT PLAN

OVERALL SITE LAYOUT PLAN

SITE LAYOUT LEGEND AND NOTES

DEMOLITION PLAN

DEMOLITION PLAN

DEMOLITION PLAN

DEMOLITION PLAN

OVERALL DEMOLITION PLAN

DEMOLITION LEGEND AND NOTES

ECF FENCE ALIGNMENT DATA SHEET SCHEDULE

ECF ROADWAY ALIGNMENT DATA SHEET SCHEDULE

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET

ALIGNMENT DATA SHEET KEY PLAN

CIVIL LEGEND AND ABBREVIATIONS

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

EXISTING CONDITIONS PLAN

OVERALL EXISTING CONDITIONS PLAN

EXISTING CONDITIONS LEGEND AND NOTES

BORING LOG SCHEDULE

BORING LOGS

BORING LOGS

BORING LOGS

OVEREXCAVATION/UNDERCUT PLAN - B129 (VCC)

BORING LOCATION PLAN

BLDG 130 - FLOOR PLAN - HAZMAT REMOVAL

BLDG 129 - VISITOR CONTROL CENTER - FLOOR PLAN - HAZMAT REMOVAL

MAINTENANCE OF TRAFFIC DETAILS

MAINTENANCE OF TRAFFIC - PHASE 3

MAINTENANCE OF TRAFFIC - PHASE 3

MAINTENANCE OF TRAFFIC - PHASE 3

MAINTENANCE OF TRAFFIC - PHASE 2

MAINTENANCE OF TRAFFIC - PHASE 2

MAINTENANCE OF TRAFFIC - PHASE 2

MAINTENANCE OF TRAFFIC - PHASE 1

MAINTENANCE OF TRAFFIC - PHASE 1

MAINTENANCE OF TRAFFIC - PHASE 1

OVERALL MAINTENANCE OF TRAFFIC PLAN

MAINTENANCE OF TRAFFIC AND SIGN LEGEND

MAINTENANCE OF TRAFFIC - GENERAL NOTES & SEQUENCE OF CONSTRUCTION

LIFE SAFETY PLAN - INSPECTION STATION

LIFE SAFETY PLAN - VISITOR CONTROL CENTER

CODE COMPLIANCE SITE PLAN

BUILDING CODE/LIFE SAFETY ANALYSIS AND LEGEND - INSPECTION STATION

BUILDING CODE/LIFE SAFETY ANALYSIS AND LEGEND - VISITOR CONTROL CENTER

CIVIL GENERAL NOTES

SHEET INDEX

SHEET INDEX

COVER SHEET

12880865

12880864

12880863

12880862

12880861

12880860

12880859

12880858

12880857

12880856

12880855

12880854

12880853

12880852

12880851

12880850

12880849

12880848

12880847

12880846

12880845

12880844

12880843

12880842

12880841

12880840

12880839

12880838

12880837

12880836

12880835

12880834

12880833

12880832

12880831

12880830

12880829

12880828

12880827

12880826

12880825

12880824

12880823

12880822

12880821

12880820

12880819

12880818

12880817

12880816

12880815

12880814

12880813

12880812

12880811

12880810

12880809

12880808

12880807

12880806

12880805

12880804

12880803

12880802

12880801

12880800

12880799

12880798

12880797

12880796

12880795

12880794

12880793

12880792

12880791

12880790

12880789

12880788

12880787

12880786

12880785

12880784

12880783

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

OVERALL EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 2

EROSION AND SEDIMENT CONTROL PLAN PHASE 2

EROSION AND SEDIMENT CONTROL PLAN PHASE 2

OVERALL EROSION AND SEDIMENT CONTROL PLAN PHASE 2

EROSION AND SEDIMENT CONTROL PLAN PHASE 1

EROSION AND SEDIMENT CONTROL PLAN PHASE 1

EROSION AND SEDIMENT CONTROL PLAN PHASE 1

OVERALL EROSION AND SEDIMENT CONTROL PLAN PHASE 1

CONSTRUCTION

EROSION AND SEDIMENT CONTROL GENERAL NOTES AND SEQUENCE OF

EROSION AND SEDIMENT CONTROL GENERAL NOTES

UTILITY DETAILS

UTILITY DETAILS

UTILITY DETAILS

UTILITY PROFILES

UTILITY SITE PLAN

OVERALL UTILITY PLAN

ENTRANCE SIGN DETAIL

SIGNS AND PAVEMENT MARKING DETAILS

SAFETY SCHEME DETAIL PLAN

SAFETY SCHEME DETAIL PLAN

SIGNS AND PAVEMENT MARKINGS PLAN

SIGNS AND PAVEMENT MARKINGS PLAN

OVERALL SIGNS AND PAVEMENT MARKINGS PLAN

SIGN AND PAVEMENT MARKING LEGEND

DRAINAGE SCHEDULE

DRAINAGE SCHEDULE

DRAINAGE SCHEDULE

DRAINAGE SCHEDULE

ROADWAY SCHEDULE

STORMWATER MANAGEMENT DETAILS

STORMWATER MANAGEMENT DETAILS

DRAINAGE DETAILS

DRAINAGE DETAILS

DRAINAGE DETAILS

DRAINAGE DETAILS

GRADING PLAN LARGE SCALE VIEW - GUARD AND TRUCK INSPECTION OFFICE

GRADING PLAN LARGE SCALE VIEW - PARKING LOT

DRAINAGE PLAN LARGE SCALE VIEW - ECF FOUNDATION AND CANOPY UNDERDRAIN

DRAINAGE PLAN LARGE SCALE VIEW - VCC FOUNDATION DRAIN

DRAINAGE PROFILES

DRAINAGE PROFILES

DRAINAGE PLAN

DRAINAGE PLAN

DRAINAGE PLAN

DRAINAGE PLAN

OVERALL DRAINAGE PLAN

GRADING PLAN

GRADING PLAN

GRADING PLAN

GRADING PLAN

OVERALL GRADING PLAN

FENCING SCHEDULE

CRASH BEAM DETAILS

CRASH BEAM DETAILS

BOLLARD DETAILS

PASSIVE VEHICLE CABLE BARRIER DETAILS

PASSIVE VEHICLE CABLE BARRIER DETAILS

PASSIVE VEHICLE CABLE BARRIER DETAILS

PASSIVE VEHICLE CABLE BARRIER DETAILS

PASSIVE VEHICLE CABLE BARRIER DETAILS

SLIDING GATE DETAILS

SWING GATE DETAILS

FENCING DETAILS

FENCING DETAILS

FENCING DETAILS

GUARDRAIL DETAILS

GUARDRAIL DETAILS

GUARDRAIL DETAILS

GUARDRAIL DETAILS

SITE LAYOUT DETAILS

SITE LAYOUT DETAILS

ID CHECK AREA ENLARGED SITE PLAN

ID CHECK AREA ENLARGED SITE PLAN

PASS AND IDENTIFICATION OFFICE AREA ENLARGED SITE PLAN

PAVEMENT JOINT DETAILS

PAVEMENT DETAILS

TYPICAL SECTIONS

TYPICAL SECTIONS

TYPICAL SECTIONS

CE110

CE109

CE108

CE107

CE106

CE105

CE104

CE103

CE102

CE101

CE100

CE002

CE001

CU503

CU502

CU501

CU200

CU101

CU100

CM501

CM500

CM401

CM400

CM102

CM101

CM100

CM001

CG604

CG603

CG602

CG601

CG600

CG505

CG504

CG503

CG502

CG501

CG500

CG403

CG402

CG401

CG400

CG201

CG200

CG109

CG108

CG107

CG106

CG105

CG104

CG103

CG102

CG101

CG100

CS600

CS518

CS517

CS516

CS515

CS514

CS513

CS512

CS511

CS510

CS509

CS508

CS507

CS506

CS505

CS504

CS503

CS502

CS501

CS500

CS402

CS401

CS400

CS308

CS307

CS306

CS305

CS304

12880947

12880946

12880945

12880944

12880943

12880942

12880941

12880940

12880939

12880938

12880937

12880936

12880935

12880934

12880933

12880932

12880931

12880930

12880929

12880928

12880927

12880926

12880925

12880924

12880923

12880922

12880921

12880920

12880919

12880918

12880917

12880916

12880915

12880914

12880913

12880912

12880911

12880910

12880909

12880908

12880907

12880906

12880905

12880904

12880903

12880902

12880901

12880900

12880899

12880898

12880897

12880896

12880895

12880894

12880893

12880892

12880891

12880890

12880889

12880888

12880887

12880886

12880885

12880884

12880883

12880882

12880881

12880880

12880879

12880878

12880877

12880876

12880875

12880874

12880873

12880872

12880871

12880870

12880869

12880868

12880867

12880866

INSPECTION STATION - BUILDING ELEVATIONS

VISITOR CONTROL CENTER - EXTERIOR ELEVATIONS

POV AND CVIS CANOPIES - ROOF PLAN

INSPECTION STATION - ROOF PLAN

VISITOR CONTROL CENTER - ROOF PLAN

POV AND CVIS CANOPIES - REFLECTED CEILING PLAN

INSPECTION STATION - REFLECTED CEILING PLAN

VISITOR CONTROL CENTER - REFLECTED CEILING PLAN

INSPECTION STATION - OVERALL FLOOR PLAN

VISITOR CONTROL CENTER - FLOOR PLAN

BUILDING 130 - DEMOLITION PLANS AND ELEVATIONS

AND WALL SECTION

VISITOR CONTROL CENTER - DEMOLITION FLOOR PLAN, REFLECTED CEILING PLAN

INSPECTION STATION - AIR BARRIER

SYMBOLS AND ABBREVIATIONS

GENERAL PROJECT NOTES, GOVERNING REGULATIONS, MATERIALS LEGEND,

TRUSS DIAGRAMS - POV AND CVIS CANOPIES

TRUSS DIAGRAMS - INSPECTION STATION

TRUSS DIAGRAMS - VISITOR CONTROL CENTER

TYPICAL DETAILS

TYPICAL DETAILS

TYPICAL DETAILS

FRAMING SECTIONS - POV AND CVIS CANOPIES

FRAMING SECTIONS - INSPECTION STATION

FRAMING SECTIONS - VISITOR CONTROL CENTER

FOUNDATION SECTIONS - INSPECTION STATION, POV AND CVIS CANOPIES

FOUNDATION SECTIONS - INSPECTION STATION, POV AND CVIS CANOPIES

FOUNDATION SECTIONS - INSPECTION STATION, POV AND CVIS CANOPIES

FOUNDATION SECTIONS - VISITOR CONTROL CENTER

CANOPY FRAMING PLAN - POV AND CVIS CANOPIES

ROOF FRAMING PLAN - INSPECTION STATION

ROOF FRAMING PLAN - VISITOR CONTROL CENTER

FOUNDATION PLAN - INSPECTION STATION, POV AND CVIS CANOPIES

FOUNDATION PLAN - VISITOR CONTROL CENTER

GENERAL NOTES

GENERAL NOTES

GENERAL NOTES

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET

ENVIRONMENTAL FEATURES SHEET KEY PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

LANDSCAPE PLAN

OVERALL LANDSCAPE PLAN

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET

WETLAND IMPACT SHEET KEY PLAN

EROSION AND SEDIMENT CONTROL DETAILS

EROSION AND SEDIMENT CONTROL PLAN PHASE 4

EROSION AND SEDIMENT CONTROL PLAN PHASE 4

OVERALL EROSION AND SEDIMENT CONTROL PLAN PHASE 4

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

EROSION AND SEDIMENT CONTROL PLAN PHASE 3

12881028

12881027

12881026

12881025

12881024

12881023

12881022

12881021

12881020

12881019

12881018

12881017

12881016

12881015

12881014

12881013

12881012

12881011

12881010

12881009

12881008

12881007

12881006

12881005

12881004

12881003

12881002

12881001

12881000

12880999

12880998

12880997

12880996

12880995

12880994

12880993

12880992

12880991

12880990

12880989

12880988

12880987

12880986

12880985

12880984

12880983

12880982

12880981

12880980

12880979

12880978

12880977

12880976

12880975

12880974

12880973

12880972

12880971

12880970

12880969

12880968

12880967

12880966

12880965

12880964

12880963

12880962

12880961

12880960

12880959

12880958

12880957

12880956

12880955

12880954

12880953

12880952

12880951

12880950

12880949

12880948

A-202

A-201

A-108

A-107

A-106

A-105

A-104

A-103

A-102

A-101

AD102

AD101

A-002

A-001

S-512

S-511

S-510

S-503

S-502

S-501

S-312

S-311

S-310

S-304

S-303

S-302

S-301

S-105

S-104

S-103

S-102

S-101

S-003

S-002

S-001

XX110

XX109

XX108

XX107

XX106

XX105

XX104

XX103

XX102

XX101

XX100

LP112

LP111

LP110

LP109

LP108

LP107

LP106

LP105

LP104

LP103

LP102

LP101

LP100

CX110

CX109

CX108

CX107

CX106

CX105

CX104

CX103

CX102

CX101

CX100

CE500

CE120

CE119

CE118

CE117

CE116

CE115

CE114

CE113

CE112

CE111

2 358

12880784

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D M

ID

A

T L

A N

T

IC

DRAWFORM REVISION: 25 AUGUST 2020

SCALE:

EPROJECT NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

1614700

CRH/LAF

IM

P

R O

V E

M E

N T S

P -3

P

E R

IM

E T

E R S

E C

U R

IT

Y

EJA

DSN

F

M E p w g f n e t p w .b e n t le y .c o m :g f n e t p w

D o c u m e n t s

P r o je c t s

C A

D D

P L

E E

T S

G F

P

G

.d

Y O

M E

P

O T T E

D

:2

E R jk n ig h t

AS NOTED

D E

P A

R T

M E

N T O

F T

H E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D

M

ID

L A

N T D

C C

O R

E N

A V

A L S

T A

T

IO

N -N

O R

F O

L K

V A

C U

T L E

R

M A

IN

E

N40085-19-D-9008 T008

02/08/23

PWD ME, via Email Approved by Jeffrey Hoyt, SEAL

DLB

S H

E E

T

IN

D E

X

G-003

NAME TITLENO. NO. NAME TITLENAVFAC NO. NAVFAC NO.

12881110

12881109

12881108

12881107

12881106

12881105

12881104

12881103

12881102

12881101

12881100

12881099

12881098

12881097

12881096

12881095

12881094

12881093

12881092

12881091

12881090

12881089

12881088

12881087

12881086

12881085

12881084

12881083

12881082

12881081

12881080

12881079

12881078

12881077

12881076

12881075

12881074

12881073

12881072

12881071

12881070

12881069

12881068

12881067

12881066

12881065

12881064

12881063

12881062

12881061

12881060

12881059

12881058

12881057

12881056

12881055

12881054

12881053

12881052

12881051

12881050

12881049

12881048

12881047

12881046

12881045

12881044

12881043

12881042

12881041

12881040

12881039

12881038

12881037

12881036

12881035

12881034

12881033

12881032

12881031

12881030

12881029

P-347 SHEET INDEX

JSK JSK TCW

LIGHTNING PROTECTION DETAILS

INSPECTION STATION, POV, AND CVIS ROOF PLAN - LIGHTNING PROTECTION

VISITORS CONTROL CENTER ROOF PLAN - LIGHTNING PROTECTION

LIGHTING DETAILS

LIGHTING DETAILS

LIGHTING FIXTURE SCHEDULE AND DETAILS

INSPECTION STATION, POV, AND CVIS CANOPIES FLOOR PLAN - ELECTRICAL LIGHTING

VISITORS CONTROL CENTER FLOOR PLAN - ELECTRICAL LIGHTING

SITE PLAN - ELECTRICAL POWER

SITE PLAN - ELECTRICAL LIGHTING

BUILDING 130 - ELECTRICAL DEMOLITION

VISITORS CENTER FLOOR PLAN - ELECTRICAL DEMOLITION

SITE PLAN - ELECTRICAL DEMOLITION

LEGEND, NOTES, AND ABBREVIATIONS

INSPECTION STATION - MECHANICAL ISOMETRIC

VISITOR CONTROL CENTER - MECHANICAL ISOMETRIC

MECHANICAL CONTROLS

MECHANICAL CONTROLS

MECHANICAL CONTROLS

MECHANICAL SCHEDULES

MECHANICAL SCHEDULES

MECHANICAL DETAILS

MECHANICAL DETAILS

MECHANICAL DETAILS

VISITOR CONTROL CENTER - ENLARGED MECHANICAL PLANS

INSPECTION STATION - MECHANICAL SECTIONS

VISITOR CONTROL CENTER - MECHANICAL SECTIONS

VISITOR CONTROL CENTER - MECHANICAL SECTIONS

VISITOR CONTROL CENTER - MECHANICAL SECTIONS

INSPECTION STATION - FLOOR PLAN - MECHANICAL HVAC

VISITOR CONTROL CENTER - FLOOR PLAN AREA B - MECHANICAL HVAC

VISITOR CONTROL CENTER - FLOOR PLAN AREA A - MECHANICAL HVAC

BUILDING 130 - FLOOR PLAN - DEMOLITION

VISITOR CONTROL CENTER - FLOOR PLAN - DEMOLITION

MECHANICAL CRITERIA, CODES AND STANDARDS

MECHANICAL LEGEND, NOTES, AND ABBREVIATIONS

PLUMBING ISOMETRICS

PLUMBING ISOMETRICS

PLUMBING ISOMETRICS

PLUMBING SCHEDULES

PLUMBING SCHEDULES

PLUMBING DETAILS

PLUMBING DETAILS

PLUMBING DETAILS

FLOOR PLAN PLUMBING - INSPECTION STATION - DOMESTIC WATER

FLOOR PLAN PLUMBING - INSPECTION STATION - SANITARY

FLOOR PLAN PLUMBING - VISITOR CONTROL CENTER - DOMESTIC WATER

FLOOR PLAN PLUMBING - VISITOR CONTROL CENTER - SANITARY

FLOOR PLAN PLUMBING - VISITOR CONTROL CENTER - DEMOLITION

PLUMBING LEGENDS, NOTES, AND ABBREVIATIONS

FIRE ALARM DETAILS

FIRE ALARM DETAILS

FIRE ALARM PLAN - INSPECTION CENTER

FIRE ALARM PLAN - VISITOR CONTROL CENTER

FIRE ALARM DEMOLITION PLANS

FIRE ALARM GENERAL NOTES AND LEGEND

INSPECTION STATION - FF&E PLAN

VISITOR CONTROL CENTER - FF&E PLAN

SIGNAGE TYPICAL DETAILS

INSPECTION STATION - SIGNAGE PLAN

VISITOR CONTROL CENTER - SIGNAGE PLAN

INSPECTION STATION - FINISH PLAN

VISITOR CONTROL CENTER - FINISH PLAN

INSPECTION STATION - FINISH SCHEDULE AND FINISH LEGEND

VISITOR CONTROL CENTER - FINISH SCHEDULE AND FINISH LEGEND

INSPECTION STATION WINDOW SCHEDULE AND DETAILS

INSPECTION STATION DOOR SCHEDULE AND DETAILS

VISITOR CONTROL CENTER - DOOR AND WINDOW SCHEDULE AND DETAILS

VISITOR CONTROL CENTER - EXTERIOR DETAILS

INSPECTION STATION - EXTERIOR DETAILS

INSPECTION STATION - EXTERIOR DETAILS

INSPECTION STATION - EXTERIOR DETAILS

CASEWORK SECTIONS

VISITOR CONTROL CENTER - ENLARGED PLANS AND INTERIOR ELEVATIONS

INSPECTION STATION - ENLARGED PLANS, ELEVATIONS, AND DETAILS

ACCESSORIES

VISITOR CONTROL CENTER - ENLARGED PLANS, ELEVATIONS, AND TOILET

POV AND CVIS CANOPIES - WALL SECTIONS

INSPECTION STATION - WALL SECTIONS

VISITOR CONTROL CENTER - WALL SECTIONS

POV AND CVIS CANOPY SECTIONS

INSPECTION STATION - BUILDING SECTIONS

VISITOR CONTROL CENTER - BUILDING SECTIONS

AUDIOVISUAL - WAITING AND SERVICE AREAS ENLARGED PLANS AND ELEVATIONS

SECURITY CCTV RISER DIAGRAMS

ACTIVE VEHICLE BARRIER DETAILS

SECURITY DETAILS

SECURITY DETAILS

SECURITY DETAILS

SECURITY DIAGRAMS AND DETAILS

SECURITY DIAGRAMS

(ESS)

INSPECTION STATION, POV, AND CVIS FLOOR PLAN - ELECTRONIC SECURITY SYSTEM

VISITORS CONTROL CENTER FLOOR PLAN - ELECTRONIC SECURITY SYSTEM (ESS)

ELECTRONIC SECURITY SYSTEM (ESS) LEGEND, NOTES, AND ABBREVIATIONS

TELECOMMUNICATIONS VOICE AND DATA BACKBONE ELEVATION DETAILS

TELECOMMUNICATIONS DETAILS

TELECOMMUNICATIONS DETAILS

INSPECTION STATION, POV, AND CVIS FLOOR PLAN - TELECOMMUNICATIONS

VISITORS CONTROL CENTER FLOOR PLAN - TELECOMMUNICATIONS

SECURITY

BUILDING 103 SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND

SECURITY

BUILDING 100 SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND

SECURITY

HELIX HOUSES SITE PLANS - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND

AND SECURITY

ENTRY CONTROL FACILITY SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

OVERALL SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP) AND SECURITY

TELECOMMUNICATIONS LEGEND, NOTES, AND ABBREVIATIONS

POWER RISER DIAGRAM

PANELBOARD SCHEDULES

PANELBOARD SCHEDULES

POWER DETAILS

POWER DETAILS

INSPECTION STATION, POV, AND CVIS FLOOR PLAN - ELECTRICAL POWER

VISITORS CONTROL CENTER FLOOR PLAN - ELECTRICAL POWER

GROUNDING RISER DIAGRAM

EG501

EG102

EG101

EL503

EL502

EL501

EL102

EL101

ES102

ES101

ED103

ED102

ED101

E-001

M-902

M-901

M-803

M-802

M-801

M-602

M-601

M-503

M-502

M-501

M-401

M-304

M-303

M-302

M-301

M-103

M-102

M-101

MD102

MD101

M-002

M-001

P-903

P-902

P-901

P-602

P-601

P-503

P-502

P-501

P-104

P-103

P-102

P-101

PD101

P-001

FA502

FA501

FA102

FA101

FD101

FA001

I-102

I-101

A-707

A-706

A-705

A-704

A-703

A-702

A-701

A-603

A-602

A-601

A-504

A-503

A-502

A-501

A-404

A-403

A-402

A-401

A-306

A-305

A-304

A-303

A-302

A-301

TA101

TY507

TY506

TY505

TY504

TY503

TY502

TY501

TY102

TY101

TY001

TN503

TN502

TN501

TN102

TN101

TS105

TS104

TS103

TS102

TS101

TN001

EP701

EP602

EP601

EP502

EP501

EP102

EP101

EG701

12881140

12881139

12881138

12881137

12881136

12881135

12881134

12881133

12881132

12881131

12881130

12881129

12881128

12881127

12881126

12881125

12881124

12881123

12881122

12881121

12881120

12881119

12881118

12881117

12881116

12881115

12881114

12881113

12881112

12881111

3 358

12880785

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D M

ID

A

T L

A N

T

IC

DRAWFORM REVISION: 25 AUGUST 2020

SCALE:

EPROJECT NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

1614700

CRH/LAF

IM

P

R O

V E

M E

N T S

P -3

P

E R

IM

E T

E R S

E C

U R

IT

Y

EJA

DSN

F

M E p w g f n e t p w .b e n t le y .c o m :g f n e t p w

D o c u m e n t s

P r o je c t s

C A

D D

P L

E E

T S

G F

P

G

.d

Y O

M E

P

O T T E

D

:5

E R jk n ig h t

AS NOTED

D E

P A

R T

M E

N T O

F T

H E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D

M

ID

L A

N T D

C C

O R

E N

A V

A L S

T A

T

IO

N -N

O R

F O

L K

V A

C U

T L E

R

M A

IN

E

N40085-19-D-9008 T008

02/08/23

PWD ME, via Email Approved by Jeffrey Hoyt, SEAL

DLB

G-004

G E

N E

R

O

T E

S

JSK JSK TCC

GENERAL SITE NOTES:

GENERAL REQUIREMENTS (ALL GROUND GRID INTERACTIONS)

PROCEDURES FOR EXCAVATING IN AREAS OF GROUND GRID

CONNECTING LEADS TO SUITABLE GROUNDING SYSTEM.

ADJACENT SECTION OF CONSTRUCTION (IE WHERE A DUCTBANK INTERSECTS A REBAR DISCONTINUOUS MANHOLE) OR AFTER FOUNDATIONS ARE BACKFILLED BEFORE TO ELIMINATE THE POTENTIAL FOR CURRENT TRAVELLING THROUGH THE REBAR, THE CONTRACTOR MAY WAIT UNTIL SUCH TIME AS REBAR IS DISCONTINUOUS WITH AN *

GROUNDING OF METAL INSTALLATIONS INCLUDING FENCES, POLES, AND SIMILAR

1.

LOCKS.

ALL GATES REQUIRE A GROUND JUMPER WIRE AROUND ALL HINGES. LOCK PLATES EITHER NEED TO BE ELECTRICALLY ISOLATED OR JUMPERS INSTALLED ACROSS THE 5.

SECURITY CABLES WILL BE GROUNDED ON BOTH ENDS.4.

FENCING INSIDE THE ARRAYS AND BOWTIE AREAS ARE TO BE GROUNDED BY AN EXOTHERMIC WELDED 4 OR 6 GAUGE WIRE TO THE GROUND GRID.3.

ROD. THE FENCING WILL REQUIRE GROUNDING THAT IS ENGINEERED WITH THE POTENTIALS FROM THE RF POWER LEVELS OF THE ARRAYS TAKEN INTO CONSIDERATION.

FENCING OUTSIDE THE ARRAYS WILL NOT BE CONNECTED TO THE EXISTING GROUND GRID. EVERY POLE IS TO BE GROUNDED WITH A 4 OR 6 GAUGE WIRE AND A GROUND 2.

ANY METAL PERMANENTLY INSTALLED ON SITE, SUCH AS A FENCE IS TO BE GROUNDED TO A SUITABLE GROUNDING SYSTEM.

MISSION APPROVALS AS EXPLAINED IN “PROCEDURES FOR EXCAVATING IN AREAS OF GROUNDING GRID” STILL APPLY. *

PERMANENT ALTERATIONS TO THE GROUND GRID

BEING EXTENDED.

NEW GROUND GRID TO BE CONNECTED TO EXISTING GRID AT PERIMETER OF DISTURBANCE WITH EXOTHERMIC WELD WITH SAME GAUGE AS THE SPECIFIC SECTION B.

ALL AFFECTED GROUND GRID IS TO BE REPLACED WITH NEW GROUND GRID A MINIMUM OF 12” BELOW FINISH ELEVATION OF WATER BODY BASE AND EDGES.A.

FOR RETENTION PONDS AND SIMILAR PROJECTS:3.

CONTINUOUS CIRCUIT.

EXISTING GROUND GRID LOCATED BELOW NEW FOOTINGS/FOUNDATION/SLAB LOCATIONS WILL BE REROUTED AROUND NEW CONSTRUCTION TO MAINTAIN A C.

ENGINEERED AND CONSTRUCTED TO PROVIDE SUFFICIENT GROUNDING OF REBAR EXPOSED TO THE RF POWER LEVELS OF THE ARRAYS.B.

GROUND BUSS AROUND EXISTING BUILDINGS IS A CONTINUOUS 1/0 COPPER WIRE. NEW STRUCTURES MUST MATCH THIS DETAIL.A.

FOR NEW STRUCTURES WITH FOUNDATIONS/SLABS:2.

ANY REBAR USED ON SITE IS TO BE CONNECTED TO THE SUITABLE GROUNDING SYSTEM.1.

OR REPLACED WITH COPPER TO MATCH EXISTING WIRE SIZE FOR THAT LOCATION.

ACCEPTABLE. NOTE THAT DIFFERENT GROUNDING GRID WIRE SIZES MAY BE ENCOUNTERED AND GROUNDING GRID WIRES MUST BE PUT BACK IN SAME LOCATION EXOTHERMIC WELD GRID PIECES BACK IN ORIGINAL LOCATION AND ATTACHED TO ORIGINAL CONDUCTOR. SPLICING IN ADDITIONAL WIRES TO ORIGINAL WIRE IS B.

UNCOVER CUT ENDSA.

RESTORING GROUND GRID (MUST ONLY BE PERFORMED DURING MISSION DOWNTIME):4.

CONNECTIONS TO REBAR GROUND LEADS MUST NOT BE MADE TO SUITABLE GROUNDING SYSTEM WHILE MISSION IS OPERATING.b.

TO SHALLOW GRID.

USE LOW GROUND PRESSURE EQUIPMENT OR ENSURE GRID IS REMOVED BEYOND THE LIMITS OF CONSTRUCTION EQUIPMENT TRAVEL TO PREVENT DAMAGE a.

PERFORM THE CONTRACT WORKA.

NEW CONSTRUCTION (MAY BE PERFORMED DURING MISSION OPERATION ONCE GROUND GRID IS SECURED):3.

THE COR MUST BE PERFORMED. ADDITIONAL GROUND GRID MUST NOT BE REMOVED WITHOUT DET CUTLER APPROVAL RECEIVED VIA THE COR.

CUTTING AND EXOTHERMIC WELDING CAN BE COMPLETED ON ADJACENT SECTIONS DURING MISSION DOWN TIMES. ONLY APPROVED CUTTING AS SUBMITTED TO NOTE THE AREA CLEARED OF GROUND GRID MUST BE BASED ON CONTRACTOR ESTIMATED PRODUCTION OPERATIONS BETWEEN DOWN DAYS AND SO THAT BOTH D.

THE WORK AREA TO PROTECT IT FROM DAMAGE DURING WORK. SPLICING IN ADDITIONAL WIRE TO RECONNECT TO ORIGINAL WIRE IS ACCEPTABLE.

LABEL CUT SECTION TO ENSURE IT CAN BE PLACED BACK IN ITS ORIGINAL LOCATION AND ATTACHED TO ORIGINAL CONDUCTOR, THEN RELOCATE IT AWAY FROM C.

SURFACE FOR FUTURE LOCATING. ALTERNATIVELY, CONTRACTOR MAY UTILIZE INSULATED MATS WITH A MINIMUM RATING OF 600 V.

MARK CUT END WITH NYLON STRING OR OTHER MEANS TO RECOVER CUT END AND COVER WITH SOIL (MIN 8”) WITH STRING OR OTHER MEANS EXPOSED TO B.

CUT GRID ON BOTH SIDES OF WORK AREA WITH SUFFICIENT CLEARANCE TO WORK AREA.A.

CUTTING GROUND GRID (MUST ONLY BE PERFORMED WHEN MISSION IS OFFLINE):2.

SIZES MAY BE ENCOUNTERED.

GRID MUST NOT BE CUT, HANDLED, OR EXOTHERMIC WELDED BACK TOGETHER WHEN MISSION IS OPERATING. NOTE THAT DIFFERENT GROUNDING GRID WIRE C.

GRID SHOULD BE EXPOSED IN AN AREA LARGER THAN THAT REQUIRED FOR THE INTENDED WORK.B.

ENCOUNTERED, IT SHOULD BE FLAGGED AND AVOIDED UNTIL THE MISSION IS OFFLINE.

REQUIREMENTS TO HAND DIG WITHIN 3’ OF ANY UTILITY. CARE SHOULD BE TAKEN NOT TO BREAK THE GROUND GRID. IF A BREAKS IN THE GROUND GRID ARE THE GROUND GRID IS SHALLOW AND ONCE LOCATED SHOULD BE EXPOSED USING NON-CONDUCTIVE HAND TOOLS IN ACCORDANCE WITH CONTRACT A.

LOCATING AND EXPOSING GROUNDING GRID (MAY BE PERFORMED DURING MISSION OPERATION):1.

DIRECTED.

GROUND DISTURBING ACTIVITIES, ALL WORK IN THE IMMEDIATE AREA MUST STOP, THE CONTRACTOR MUST NOTIFY THE COR, AND WORK MUST NOT BE RESUMED UNTIL SO EXCAVATION IS OUTSIDE OF IDENTIFIED AREAS OF ARCHAEOLOGICAL SENSITIVITY. IN THE EVENT A POTENTIAL ARCHAEOLOGICAL RESOURCE IS ENCOUNTERED DURING 36.

FEET IF PARALLEL WITHIN 5 FEET OF THE EXCAVATION.

PERFORMED USING WOOD- OR FIBERGLASS-HANDLED TOOLS. IF CONSTRUCTION IS PARALLEL TO AN EXISTING UTILITY, EXPOSE THE UTILITY BY HAND DIGGING EVERY 100

ANY REBAR IS TO BE PROVIDED WITH A SUITABLE COPPER PIGTAIL AND BE EXOTHERMICALLY WELDED TO A SUITABLE GROUNDING SYSTEM BASED ON LOCATION.5.

1.

WHERE SPLICING OCCURS, SPLICE MATERIAL TO MATCH GAUGE OF EXISTING.7.

ANY WORK NOT SPECIFICALLY DESCRIBED IN THIS DOCUMENT MUST BE REVIEWED WITH THE COR TO DETERMINE REQUIRED APPROVALS.6.

NOTE THAT THE GROUND GRID VARIES IN SIZE AND ANY REPAIRS MADE SHOULD BE THE SAME GAUGE AS THE SPECIFIC WIRE BEING REPAIRED.4.

BE CUT WITHOUT MISSION APPROVAL RECEIVED VIA THE COR.

DRAWING WHAT GROUND GRID HAS BEEN LOCATED IN THE AREA OF WORK AND ALL PLANNED ACTIVITIES INVOLVING INTERACTION WITH THE GROUND GRID. NO GRID MAY A MINIMUM OF TEN DAYS PRIOR TO PLANNED ACTIVITIES THAT INVOLVE THE GROUND GRID, SUBMIT TO THE COR A DETAILED WORK PLAN WHICH ALSO INDICATES ON A 3.

CONTRACT DOCUMENTS IS TO BE ADHERED TO. THIS INCLUDES, BUT IS NOT LIMITED TO APPROPRIATE UTILITY LOCATING TO LOCATE THE GROUND GRID.

THE GROUND GRID IS CONSIDERED AN UNDERGROUND UTILITY. REQUIREMENTS RELATED TO IDENTIFYING, MARKING, INTERACTION, ETC AS SPECIFIED IN THE 2.

NO EXCAVATION IS TO OCCUR WITHOUT APPROVAL GAINED FROM NSA CUTLER VIA THE CONTRACTING OFFICER REPRESENTATIVE (COR).2.

REPAIRED PRIOR TO COMPLETING THE REPAIR(S) AND DOCUMENT THESE LOCATIONS TO BE INCLUDED ON THE AS-BUILT DRAWINGS.

RESTORE GROUNDING GRID AFFECTED OR DAMAGED BY CONTRACTORS' OPERATIONS. NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE OF AREAS THAT WILL BE

AS INDICATED IN THE SPECIFIC REQUIREMENTS FOR THE GROUNDING GRID INCLUDED WITHIN THE CONTRACT DOCUMENTS.B.

AS DIRECTED IN THE SPECIFICATIONS FOR BURIED UTILITIES SUCH AS ELECTRIC AND GAS.A.

GRID WIRE IS CONNECTED TOGETHER VIA EXOTHERMIC WELDS (CADWELD). THE GROUNDING GRID IS CONSIDERED A "BURIED UTILITY" AND SHOULD BE TREATED:

EXISTING NO. 6 AWG BARE COPPER GROUNDING GRID IS BURIED APPROXIMATELY 3"-12" BELOW SURFACE IN THE ENTIRE SCOPE OF WORK AREA. EXISTING GROUNDING 1.

THE UNDERGROUND SYSTEM. DIGGING WITHIN 3 FEET OF A KNOWN UTILITY MUST NOT BE PERFORMED BY MEANS OF MECHANICAL EQUIPMENT; HAND DIGGING MUST BE PHYSICALLY VERIFY UNDERGROUND, INCLUDING UTILITY DEPTH, BY HAND DIGGING WHEN ADJACENT CONSTRUCTION WORK IS EXPECTED TO COME WITHIN 3 FEET OF

UTILITY LOCATIONS VERIFICATION:35.

CONSTRUCTION. MARKINGS MADE DURING THE UTILITY INVESTIGATION MUST BE MAINTAINED THROUGHOUT THE CONTRACT.

MUST LOCATE UTILITY DEPTH BY USE OF GROUND PENETRATING RADAR (GPR), X-RAY, BORE SCOPE, OR ULTRASOUND PRIOR TO THE START OF DEMOLITION AND PARTY, INDEPENDENT, PRIVATE LOCATING COMPANY TO LOCATE UTILITIES WITHIN THE LIMITS OF WORK. THE THIRD PARTY, INDEPENDENT, PRIVATE LOCATING COMPANY UNDERGROUND UTILITIES IN THE WORK AREA MUST BE POSITIVELY IDENTIFIED PRIOR TO COMMENCING WITH EXCAVATION WORK. PROVIDE THE SERVICES OF A THIRD

UTILITY LOCATIONS:34.

CONTRACTOR MAY BE REQUIRED TO CONDUCT TESTING TO DETERMINE THE SEVERITY OF THE CONTAMINATION.

IMMEDIATELY AND NOTIFICATION MUST BE PROVIDED TO THE CONTRACTING OFFICER'S REPRESENTATIVE. THE GOVERNMENT WILL PROVIDE DIRECTION. THE IF SUSPECT CONTAMINATION IS ENCOUNTERED IN SOIL OUTSIDE OF AN INSTALLATION RESTORATION SITE (EG- ODOR, STAINING, DEBRIS, ETC.), EXCAVATION MUST STOP 33.

SOIL EXCAVATED FROM NON-INSTALLATION RESTORATION AREAS MAY BE USED AS BACKFILL GIVEN IT MEETS PROJECT SPECIFICATIONS.32.

CUTLER. THE HAZARDOUS WASTE MANIFESTS MUST BE SIGNED BY THE DESIGNATED PWD-ME ENVIRONMENTAL PERSONNEL.

NON-MUNICIPAL LANDFILL FACILITY. PWD-ME ENVIRONMENTAL IS THE SIGNATORY AUTHORITY FOR HAZARDOUS WASTE MANIFESTS FOR WASTE GENERATED AT NSA SOIL EXCAVATED FROM INSTALLATION RESTORATION SITE MUST NOT BE REUSED FOR BACKFILL, BUT RATHER, TRANSPORTED AND DISPOSED OF AT A LICENSED 31.

FROM WHICH IT WAS EXCAVATED.

RESTORATION SITE MUST BE STOCKPILED ON, AND COVERED WITH, SIX MIL POLYETHYLENE SHEETING WITHIN THE SAME INSTALLATION RESTORATION SITE BOUNDARY MANAGEMENT PRACTICES (BMPS) AND STOCKPILED OUTSIDE THE LIMITS OF AN INSTALLATION RESTORATION SITE.X. EXCAVATED SOIL FROM AN INSTALLATION EXCAVATED SOIL FROM NON-INSTALLATION RESTORATION AREAS MUST BE MANAGED ACCORDING TO THE STATE OF MAINE EROSION & SEDIMENT CONTROL BEST 30.

HAZARDOUS WASTE OPERATIONS AND EMERGENCY RESPONSE (HAZWOPER) CONTROLS.

EXCAVATION WITHIN INSTALLATION RESTORATION SITES MUST BE CONDUCTED UNDER A SITE-SPECIFIC HEALTH & SAFETY PLAN (HASP) OUTLINING THE NECESSARY 29.

LABORATORY FOR CHEMICAL ANALYSES.

A QUALIFIED ENVIRONMENTA L PROFESSIONAL FOLLOWING ALL FEDERAL AND STATE SAMPLING PROTOCOL. SAMPLES MUST BE SENT TO A STATE LICENSED A WASTE CHARACTERIZATION SAMPLING PLAN MUST BE SUBMITTED TO PWD-ME ENVIRONMENTAL FOR REVIEW PRIOR TO SAMPLING. SAMPLING MUST BE CONDUCTED BY 28.

SOIL MUST BE TESTED FOR CONTAMINANTS AS PRESCRIBED AND REQUIRED BY THE SELECTED LANDFILL.27.

PWD-ME ENVIRONMENTAL.

SOIL TRANSPORTED OFF NSA CUTLER MUST BE DISPOSED OF AT A LICENSED NON-MUNICIPAL LANDFILL FACILITY. LANDFILL SELECTION MUST BE REVIEWED BY 26.

CONTRACTOR WHICH INCLUDE, BUT ARE NOT LIMITED TO: STOCKPILING, TESTING, TRANSPORT, AND DISPOSAL.

COSTS ASSOCIATED WITH EXCAVATION AND SOIL MANAGEMENT BOTH INSIDE AND OUTSIDE INSTALLATION RESTORATION SITES ARE THE RESPONSIBILITY OF THE 25.

FIELD PRIOR TO THE START OF CONSTRUCTION, AND FLAGGED THROUGHOUT CONSTRUCTION.

WETLAND BOUNDARIES, LIMITS OF JURISDICTIONAL IMPACTS, AND INSTALLATION RESTORATION LAND USE CONTROL BOUNDARIES MUST BE CLEARLY MARKED IN THE 24.

VERSION 2.0 AS NOTED IN THE JURISDICTIONAL DETERMINATION DATED 3 FEBRUARY 2015.

DETERMINATIONS METHOD AND THE REGIONAL SUPPLEMENT TO THE CORPS OF ENGINEERS WETLAND DELINEATING MANUAL: NORTHCENTRAL AND NORTHEAST REGION, ACCORDANCE WITH THE UNITED STATES ARMY CORPS OF ENGINEERS WETLANDS DELINEATION MANUAL (ENVIRONMENTAL LABORATORY 1987), ROUTINE WETLAND BOUNDARIES WERE OBTAINED FROM THE NAVFAC MIDLANT GEOREADINESS CENTERS, GIS DATABASE. WETLAND BOUNDARIES WERE DELINEATED IN 23.

THE BOTTOM OF THE FENCE MESH OR BOTTOM BAR.

STEP FENCING MAX 2-FT INCREMENTS TO FOLLOW GRADES IN A MANNER WHICH MAINTAINS THE INDICATED FENCE HEIGHT WITHOUT LEAVING VOIDS OR GAPS ALONG 22.

PHASE TO RESOLVE RELATED DISCREPANCIES.

DETAILED DRAWING FOR SUCH WALLS AS THEY CORRESPOND TO DESIGN-FINISHED GRADE ELEVATIONS. SEEK CLARIFICATION REGARDING QUANTITIES DURING BID SITE WALLS (FREE-STANDING OR RETAINING TYPES) EXTEND ABOVE AND BELOW FINISHED GRADE ELEVATIONS. ADJUST QUANTITIES AND CONSTRUCTION BASED ON 21.

LOCAL STANDARD DETAILS (AT A MINIMUM, AT THE FREQUENCY INDICATED IN SUCH DOCUMENTS).

STANDARD PIV, FDC, FIRE LANE, AND “NO PARKING” SIGNAGE, STRIPING, LETTER STENCILING, AND PAINTED CURBS ARE INCLUDED AS INDICATED IN DRAWINGS AND 20.

LOCATION OF UNDERGROUND UTILITIES AND PROVIDE SUCH ITEMS ONLY AFTER STABLE DESIGN GRADE IS REACHED WITHIN THE VICINITY OF THE IMPROVEMENT.

COORDINATE THE CONSTRUCTION OF FOUNDATIONS FOR FENCE POSTS, SIGN POSTS, LIGHT/LAMP POLES, BOLLARDS, AND SIMILAR WORK WITH THE CONFIRMED 19.

INVESTIGATION.

THE WORK INCLUDES LABOR, MATERIALS, AND EQUIPMENT REASONABLY ANTICIPATED BASED ON PLANS AND REFERENCED DOCUMENTS WITH PRE-BID SITE 18.

APPROVED EQUAL: IS DEFINED AS EQUIVALENT SOLUTION OR PRODUCT WHICH HAS BEEN FORMALLY CONFIRMED BY THE CONTRACTING OFFICER.17.

READ.

ONLY PERFORM ON- OR OFF-SITE WORK AFTER CONFIRMING REQUIRED EASEMENTS, AGREEMENTS, PERMITS, BONDS, AND NOTIFICATIONS ARE EXECUTED, ISSUED, AND 16.

COUNTERACT THE WIND AND AVOID DEBRIS BEING SCATTERED AS A RESULT.

ELIMINATE ABNORMALLY LARGE ACCUMULATIONS ON-SITE IN THE OPINION OF THE ENGINEER AND CONTRACTING OFFICER. MEASURES MUST BE TAKEN AT ALL TIMES TO MINIMUM, WILL AVOID INTERFERING WITH OTHER WORK, AVOID ADVERSELY IMPACTING NORMAL OPERATIONS WHICH WERE PLANNED TO CONTINUE IN THE VICINITY, AND HAUL AWAY ACCUMULATED WASTE OR OTHER MATERIAL (EXCEPTING EXCAVATED SOIL MATERIAL, SEE NOTE 5 ON SHEET CD001) REMOVED AT A FREQUENCY WHICH, AT A 15.

INTERMEDIATE PHASES AS WELL (I.E. PLANTINGS IN PLANTING SEASON AFTER CLOSEOUT FOR THE REMAINDER OF THE PROJECT).

BY THE CONTRACTING OFFICER OR CONTRACTING OFFICER'S REPRESENTATIVE. THIS MUST ALSO APPLY TO PARTIAL CLOSEOUT MILESTONES FOR EARLY OR REMOVE SURPLUS MATERIALS, GARBAGE, DEBRIS, CONSTRUCTION EQUIPMENT, OR SIMILAR ITEMS BEFORE OR AT CLOSEOUT UNLESS OTHERWISE INDICATED IN WRITING 14.

UTILITIES IN AREAS NOT MARKED BY DIG SAFE.

THROUGHOUT THE PROJECT AND SUPPLEMENT USING AVAILABLE RECORDS AND AS-BUILTS. UTILIZE THE SERVICES OF A PRIVATE UTILITY LOCATOR TO MARK EXISTING FIELD VERIFY DEPTH, UTILITY DIMENSIONS, MATERIAL, AND TYPE OF UTILITIES (THOSE MARKED AND UNMARKED BY MISS UTILITY) PRIOR TO WORK. REPEAT THIS EFFORT NOTIFY DIG SAFE (811) OF PENDING WORK. ORDER UTILITY MARKING AND/OR FLAGGING OF UNDERGROUND UTILITIES NO LESS THAN 4 BUSINESS DAYS BEFORE WORK. 13.

LENGTHS MEASURED USING THESE SAME REFERENCE POINTS.

SECTION, CENTER OF PAVEMENT MARKING STRIPE, AND PROPERTY LINE OR RIGHT-OF-WAY LINE UNLESS OTHERWISE INDICATED. PIPE SLOPES INDICATED ARE BASED ON DIMENSIONS ARE FROM FACE OF CURB, EDGE OF PAVEMENT, FACE OF WALL, CENTER OF UTILITY STRUCTURE, CENTERLINE OF PIPE, END OF PIPE (FLARED)-END 12.

REPRESENTATIVE) PRIOR TO COMMENCING WITH CORRESPONDING WORK.

SUBSTITUTIONS AND DEVIATIONS FROM THE CONTRACT DOCUMENTS MUST BE APPROVED IN WRITING BY THE CONTRACTING OFFICER (OR CONTRACTING OFFICER'S 11.

POSSIBLY BE VOIDING MANUFACTURER WARRANTIES. THIS DOES NOT RELIEVE THE CONTRACTOR OF WARRANTIES REQUIRED IN THE CONTRACT DOCUMENTS.

RECOMMENDATIONS OR AS NOTED BY THE ENGINEER. IMMEDIATELY SUBMIT AN RFI FOR CONFIRMATION IF ENGINEER'S RECOMMENDATIONS ARE BELIEVED TO APPLY, PROVIDE, REPAIR, STORE, HANDLE, HAUL, AND MAINTAIN MATERIALS, PRODUCTS, AND EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S 10.

DOCUMENTS. SURVEYOR TO PROVIDE DRAWING OF PROPERTY LINES AND STRUCTURES ADJACENT TO IT AFTER WORK IS COMPLETE.

LAYOUT THE CONSTRUCTION STAKING FOR WORK USING THE SAME DATUMS AS USED IN THE PROJECT SURVEY PROVIDED FOR REFERENCE IN THE CONTRACT HIRE A MAINE-LICENSED LAND SURVEYOR TO CONFIRM AND ESTABLISH (OR RE-ESTABLISH) TEMPORARY BENCHMARKS, VERIFY AND STAKE OUT PROPERTY LINES, AND 9.

CONSTRUCTION OR TO THE ADJACENT PROPERTIES.

REMAIN", AND TO OTHER COMPLETED WORK - REPAIR OR REPLACE TO THE CONTRACTING OFFICER'S SATISFACTION ITEMS DAMAGED WITHIN THE LIMITS OF NO WORK IS TO BE PERFORMED ON PROPERTY NOT OWNED BY THE NAVY. AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES, ITEMS WHICH ARE "EXISTING TO 8.

CONTRACTING OFFICER WILL NOTIFY THE ENGINEER OF RECORD.

MAY INCLUDE, BUT IS NOT LIMITED TO, APPARENT CONFLICTS WITH EXISTING UNDERGROUND UTILITIES AND STRUCTURES, GRADE ELEVATIONS, AND SIGNAGE. THE DISCIPLINES) BEFORE PROCEEDING WITH WORK. THIS MUST BE DONE IMMEDIATELY BY PHONE AND THEN IN WRITING WITHIN TWENTY FOUR HOURS OF DISCOVERY. THIS NOTIFY THE CONTRACTING OFFICER OF DISCREPANCIES DISCOVERED BETWEEN EXISTING CONDITIONS AND DRAWINGS (OR BETWEEN DRAWINGS OF DIFFERENT DESIGN 7.

(TEMPORARY) ARE IN PLACE, AND PROCEDURES RELATED TO THE GROUNDING GRID HAVE BEEN COMPLETED.

DO NOT CONDUCT LAND-DISTURBING ACTIVITIES UNTIL SITE PERMITS ARE CONFIRMED AND EROSION & SEDIMENT CONTROL, PLANT/TREE PROTECTION, SITE FENCING 6.

MUST TAKE PRECEDENCE OVER THE DRAWINGS.

IN CASES WHERE THE CIVIL SITE AND PLANTING DRAWINGS CONFLICT WITH PROCEDURAL AND CONTRACTUAL ELEMENTS FROM THE CONTRACTING OFFICER, THE LATTER 5.

NOTES MUST TAKE PRECEDENCE.

IN CASES WHERE THESE CIVIL SITE AND PLANTING DRAWINGS CONFLICT WITH STANDARD NOTES REQUIRED BY THE GOVERNING AUTHORITY, THE LISTED GOVERNMENT 4.

INCLUDING, BUT NOT LIMITED TO: DESIGN, PROVISION, AND MAINTENANCE OF BRACING, SHORING, AND TEMPORARY SUPPORTS.

CONTINUOUSLY PROVIDE GOVERNMENT-REQUIRED SAFETY MEASURES AND PRACTICES TO PROTECT PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK3.

PROVIDE LABOR, MATERIALS, EQUIPMENT, AND COORDINATION NECESSARY TO COMPLETE WORK INDICATED AND BY CONTRACTED SCHEDULE.

4 358

12880786

CPT = XX FT

LEGENDAPPLICABLE BUILDING CODES INTERIOR FINISH CLASSIFICATION

TRAVEL DISTANCES

CAPACITY OF EXITS

ADDITIONAL LIFE SAFETY CRITERIA

MEANS OF EGRESS

COMMON PATH OF TRAVEL DISTANCE

1.

2.

3.

4.

5.

6.

7.

UFC 1-200-01

UFC 3-600-01

IBC

NFPA 70

NFPA 72

NFPA 101

ABA

DOD BUILDING CODE, 8 OCTOBER 2019

FIRE PROTECTION ENGINEERING FOR FACILITIES, 12 AUGUST 2020

INTERNATIONAL BUILDING CODE, 2018

NATIONAL ELECTRIC CODE, 2020

NATIONAL FIRE ALARM AND SIGNAL CODE, 2019

LIFE SAFETY CODE, 2018 (LSC)

ARCHITECTURAL BARRIERS ACT

AREA USE

APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

FIRST FLOOR

LIMITS (BASED ON BUSINESS OCCUPANCY):

EXITS (LSC TABLE A.10.2.2)

EXIT ACCESS CORRIDORS (LSC TABLE A.10.2.2)

OTHER SPACES (LSC TABLE A.10.2.2)

OCCUPANT LOADS (LSC TABLE 7.3.1.2)

BUSINESS 150 SF/PERSON

ASSEMBLY USE 15 SF/PERSON

COMMON PATH OF TRAVEL BUSINESS (LSC TABLE A.7.6): 75-FT

DEAD END CORRIDOR BUSINESS (LSC TABLE A.7.6): 20-FT

EXIT ACCESS TRAVEL DISTANCE BUSINESS (LSC TABLE A.7.6): 200-FT

CAPACITY OF EXITS (LSC TABLE 7.3.3.1):

LEVEL COMPONENTS (WIDTH/PERSON) 0.2 IN/PERSON

NUMBER OF EXITS (LSC 7.4):

2 EXITS FOR AREAS WITH AN OCCUPANT LOAD LESS THAN 500

EMERGENCY LIGHTING SYSTEMS MUST BE PROVIDED IN ACCORDANCE WITH LSC 7.9.2.1 & 7.9.2.2 (LSC 38.2.8).

MEANS OF EGRESS MUST BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 AND UFC 3-600-01 10-2

(LSC 38.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED

SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE

TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED. RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED

(UFC 3-600-01 10-2.2).

FLOOR LEVEL

REQUIRED EXIT

CAPACITY

AVAILABLE EXIT

CAPACITY

NUMBER OF

EXITS REQUIRED

NUMBER OF

EXITS PROVIDED

3251028

OFFICE AREAS BUSINESS 1,669 11150

FIRST FLOOR

WAITING - 102 132 915

TOTAL 2,093 28-

TD = XX FT

## REQUIRED EGRESS CAPACITY

PROVIDED EGRESS CAPACITY

OCCUPANT LOAD

TRAVEL DISTANCE

FIRE EXTINGUISHER (4-A:80-B:C)FE

xx

USE GROUP/OCCUPANCY

FIRE PROTECTION SYSTEMS

CONSTRUCTION TYPE

FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS

INTERIOR FIRE RESISTANCE REQUIREMENTS

ALLOWABLE AREA & HEIGHT

ACTUAL AREA & HEIGHT

EXTERIOR WALLS

B (IBC 304.1) / BUSINESS (LSC CHAPTER 38)

R-3: CONGREGATE LIVING-TRANSIENT (IBC 310.5) / LODGING OR ROOMING HOUSE (LSC CHAPTER 26)

PER IBC, THE BUILDING IS CLASSIFIED AS A GROUP B OCCUPANCY WITH ACCESSORY GROUP R-3 OCCUPANCY.

PER LSC, THE BUILDING IS CLASSIFIED AS MIXED USE LODGING OR ROOMING HOUSE AND BUSINESS OCCUPANCIES.

FIRE ALARM SYSTEM

SPRINKLER SYSTEM - NOT REQUIRED

VISITOR CONTROL CENTER TYPE V-B

BASED ON B USE GROUP

ALLOWABLE FLOOR AREA B (IBC TABLE 506.2 ):

ALLOWABLE STORIES FOR B (IBC TABLE 504.4):

ALLOWABLE HEIGHT FOR B (IBC TABLE 504.3):

TOTAL FOOTPRINT FLOOR AREA 2,243-SF

BUILDING HEIGHT

(IBC TABLE 601, TYPE V-B CONSTRUCTION)

STRUCTURAL FRAME, INCL. COLUMNS, GIRDERS & TRUSSES 0-HR

BEARING WALLS, EXTERIOR 0-HR

BEARING WALLS, INTERIOR 0-HR

NON-BEARING WALLS, INTERIOR & EXTERIOR 0-HR

FLOOR CONSTRUCTION 0-HR

ROOF CONSTRUCTION 0-HR

EXTERIOR FIRE-RESISTANCE RATING BASED ON FIRE SEPARATION DISTANCE (TYPE V-B)

THE DISTANCE BETWEEN THE VISITOR CONTROL CENTER AND THE CLOSEST BUILDING IS GREATER THAN 40-FT, WHICH PROVIDES A FIRE SEPARATION DISTANCE OF AT LEAST 10-FT FROM THE VISITOR CONTROL CENTER TO THE IMAGINARY LOT LINE AND MORE THAN 30-FT FROM THE IMAGINARY LOT LINE TO THE CLOSEST BUILDING; THEREFORE, THE EXTERIOR WALLS OF THE VISITOR CONTROL CENTER ARE NOT REQUIRED TO BE RATED.

FIRE SEPARATION DISTANCE (FSD)

FSD < 10-FT

GROUP B

1-HR

FSD > 10-FT 0-HR

SLEEPING ROOMS (LSC 26.3.5.1) SMOKE PARTITIONS

MECHANICAL ROOMS W/FUEL-FIRED EQUIPMENT (LSC 38.3.2.1 & 8.7.1.1(1)) 1-HR FIRE BARRIER

ASSEMBLY

FIRE EXTINGUISHERS MUST BE PROVIDED AND LOCATED IN ACCORDANCE WITH NFPA 10 (LSC 38.3.5).

9,000-SF

2-STORIES

40-FT

1-STORY / 16-FT

MINIMUM CLASS B

MINIMUM CLASS B

MINIMUM CLASS C

DAYROOM - 121 LODGING ROOMS 93 1200

VISITOR CONTROL CENTER

LOCKER ROOMS 50 SF/PERSON SMOKE PARTITIONSP

1-HR FIRE BARRIER

LODGING ROOMS 200 SF/PERSON

LOCKER ROOM - 115 LOCKER ROOMS 121 250

BREAK ROOM - 110 78 515ASSEMBLY

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

GI001

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

B U

IL

D

IN

G

C O

D E

/L

IF

E S

A F

E

TY

A N

A

LY

S

IS

A N

D L

E G

E N

D

V

IS

IT

O

R C

O N

TR

O

L C

E N

TE

R

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

G I0

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

5 358

12880787

TD = XX FT

LEGENDAPPLICABLE BUILDING CODES

USE GROUP/OCCUPANCY

FIRE PROTECTION SYSTEMS

CONSTRUCTION TYPE

FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS

INTERIOR FIRE RESISTANCE REQUIREMENTS

INTERIOR FINISH CLASSIFICATION

TRAVEL DISTANCES

CAPACITY OF EXITS

ADDITIONAL LIFE SAFETY CRITERIA

MEANS OF EGRESS

ALLOWABLE AREA & HEIGHT

ACTUAL AREA & HEIGHT

EXTERIOR WALLS

REQUIRED EGRESS CAPACITY

PROVIDED EGRESS CAPACITY

OCCUPANT LOAD

TRAVEL DISTANCE

FIRE EXTINGUISHER (4-A:80-B:C)

1.

2.

3.

4.

5.

UFC 1-200-01

UFC 3-600-01

IBC

NFPA 101

ABA

DOD BUILDING CODE, 8 OCTOBER 2019

FIRE PROTECTION ENGINEERING FOR FACILITIES, 12 AUGUST 2020

INTERNATIONAL BUILDING CODE, 2018

LIFE SAFETY CODE, 2018 (LSC)

ARCHITECTURAL BARRIERS ACT

B (IBC 304.1) / BUSINESS (LSC CHAPTER 38)

FIRE ALARM SYSTEM - NOT REQUIRED

SPRINKLER SYSTEM - NOT REQUIRED

INSPECTION STATION TYPE II-B

BASED ON B USE GROUP

ALLOWABLE FLOOR AREA B (IBC TABLE 506.2 ):

ALLOWABLE STORIES FOR B (IBC TABLE 504.4):

ALLOWABLE HEIGHT FOR B (IBC TABLE 504.3):

TOTAL FOOTPRINT FLOOR AREA 1,473-SF

BUILDING HEIGHT

(IBC TABLE 601, TYPE II-B CONSTRUCTION)

STRUCTURAL FRAME, INCL. COLUMNS, GIRDERS & TRUSSES 0-HR

BEARING WALLS, EXTERIOR 0-HR

BEARING WALLS, INTERIOR 0-HR

NON-BEARING WALLS, INTERIOR & EXTERIOR 0-HR

FLOOR CONSTRUCTION 0-HR

ROOF CONSTRUCTION 0-HR

EXTERIOR FIRE-RESISTANCE RATING BASED ON FIRE SEPARATION DISTANCE (TYPE II-B)

THE DISTANCE BETWEEN THE INSPECTION STATION AND THE CLOSEST BUILDING IS GREATER THAN 40-FT, WHICH PROVIDES A FIRE SEPARATION DISTANCE OF AT LEAST 10-FT FROM THE INSPECTION STATION TO THE IMAGINARY LOT LINE AND MORE THAN 30-FT FROM THE IMAGINARY LOT LINE TO THE CLOSET BUILDING; THEREFORE, THE EXTERIOR

WALLS OF THE INSPECTION STATION ARE NOT REQUIRED TO BE RATED.

AREA USE

APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

FIRST FLOOR

LIMITS (BASED ON BUSINESS OCCUPANCY):

EXITS (LSC TABLE A.10.2.2)

EXIT ACCESS CORRIDORS (LSC TABLE A.10.2.2)

OTHER SPACES (LSC TABLE A.10.2.2)

OCCUPANT LOADS (LSC TABLE 7.3.1.2)

BUSINESS 150 SF/PERSON

COMMON PATH OF TRAVEL BUSINESS (LSC TABLE A.7.6): 75-FT

DEAD END CORRIDOR BUSINESS (LSC TABLE A.7.6): 20-FT

EXIT ACCESS TRAVEL DISTANCE BUSINESS (LSC TABLE A.7.6): 200-FT

CAPACITY OF EXITS (LSC TABLE 7.3.3.1):

LEVEL COMPONENTS (WIDTH/PERSON) 0.2 IN/PERSON

NUMBER OF EXITS (LSC 7.4):

2 EXITS FOR AREAS WITH AN OCCUPANT LOAD LESS THAN 500

1 EXIT FOR AREAS WITH AN OCCUPANT LOAD LESS THAN 100 AND LESS THAN 100-FT TRAVEL DISTANCE(LSC 38.2.4.3)

EMERGENCY LIGHTING SYSTEMS MUST BE PROVIDED IN ACCORDANCE WITH LSC 7.9.2.1 & 7.9.2.2 (LSC 38.2.8).

MEANS OF EGRESS MUST BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 AND UFC 3-600-01 10-2

(LSC 38.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED

SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE

TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED. RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED

(UFC 3-600-01 10-2.2).

FLOOR LEVEL

REQUIRED EXIT

CAPACITY

AVAILABLE EXIT

CAPACITY

NUMBER OF

EXITS REQUIRED

NUMBER OF

EXITS PROVIDED

1117017

FIRE SEPARATION DISTANCE (FSD)

FSD < 10-FT

GROUP B

1-HR

OFFICE USE BUSINESS 1,100 7150

FIRST FLOOR

69 515

FSD > 10-FT 0-HR

FE

MECHANICAL ROOMS W/FUEL-FIRED EQUIPMENT (LSC 38.3.2.1 & 8.7.1.1(1)) 1-HR FIRE BARRIER xx

FIRE EXTINGUISHERS MUST BE PROVIDED AND LOCATED IN ACCORDANCE WITH NFPA 10 (LSC 38.3.5).

1-STORY / 17-FT

23,000-SF

3-STORIES

55-FT

MINIMUM CLASS B

MINIMUM CLASS B

MINIMUM CLASS C

ASSEMBLY (LESS CONCENTRATED) 15 SF/PERSON

1,240 17-TOTAL

ASSEMBLYWAITING - 107

INSPECTION STATION

1-HR FIRE BARRIER

71 515ASSEMBLYBREAK ROOM - 105

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EA

LTHOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:0

:3

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_

IS

F

IR

E

R

.r v t

GI002

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

B U

IL

D

IN

G

C O

D E

/L

IF

E S

A F

E

TY

A N

A

LY

S

IS

A N

D L

E G

E N

D

IN

S

P E

C

TI

O N

S

TA

TI

O

N

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

G I0

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

6 358

12880788

0 50' 100'

IPL

30-FT

IPL

30-FT

CODE COMPLIANCE SITE PLANA1

INSPECTION STATION

VISITOR CONTROL CENTER

SCALE: 1" = 50'-0"GI003

30'

10'

NOTES:

FH - FIRE HYDRANT

IPL- IMAGINARY PROPERTY LINE

30-FT - MINIMUM 30-FT FROM IPL FOR ADJACENT BUILDINGS

30' 10'

NEAREST BUILDING IS 150-FT FROM

THE VISITOR CONTROL CENTER

UNDERGROUND

FIRE WATER

TANKS

FH

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

GI003

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

C O

D E

C O

M P

LI

A

N C

E S

IT

E

P

LA

N

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

G I0

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

7 358

12880789

F

SP SPSP

S P

S P

S P

S P

S P

S P

TD = 52 FT

FE

CPT = 18 FT

85' - 4"

60' - 1"

1 2

VESTIBULE

TOILET

BREAKROOM

MUD ROOM

SIPRNET

EXIST

OFFICE

ADMIN/COPY

106 ID/CHECK-IN

HALLWAY

WAITING

TOILET

LAUNDRY

MOTHER'S

SHOWER

COMM

OFFICE

MECH/ELEC

INTERVIEW

HALLWAY

HALLWAY

LOCKER ROOM

HALLWAY

DAYROOM

JANITOR

FE

GENERAL SHEET NOTES

1. SEE SHEET GI001 FOR BUILDING CODE/LIFE SAFETY ANALYSIS AND

LEGEND.

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

GI101

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

LI

F

E S

A F

E

TY

P

LA

N

V

IS

IT

O

R C

O N

TR

O

L C

E N

TE

R

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

G I1

PLAN

NORTH

SCALE: 1/4" = 1'-0"

LIFE SAFETY PLAN - VISITOR CONTROL CENTER

2' 4' 8'0' 1/4" =1'-0"

GRAPHIC SCALE(S)

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

8 358

12880790

B D E

A C

MECH/ELEC

STOR/JAN

BREAKROOM

CORR

WAITING

RFI/SECURE ROOM

INSPECTION OFFICE

TD = 59 FT

FE

FE

COMM

RESTROOM

STORAGE

GENERAL SHEET NOTES

1. SEE SHEET GI002 FOR BUILDING CODE/LIFE SAFETY SUMMARY AND

LEGEND.

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EA

LTHOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:0

:3

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_

IS

F

IR

E

R

.r v t

GI102

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

LI

F

E S

A F

E

TY

P

LA

N

IN

S

P E

C

TI

O N

S

TA

TI

O

N

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

G I1

4' 8' 16'0' 1/8" =1'-0"

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LI…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .