DRAWFORM REVISION: 25 AUGUST 2020
SCALE:
EPROJECT NO.
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
SHEET OF
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
1614700
CRH/LAF
IM
P
R O
V E
M E
N T S
P -3
P
E R
IM
E T
E R S
E C
U R
IT
Y
EJA
DSN
F
IL
E
M E p w g f n e t p w .b e n t le y .c o m :g f n e t p w
D o c u m e n t s
P r o je c t s
C A
D D
P L
S H
E E
T S
G F
P
C S .d g n
L
Y O
U T
M E
P lo t
P L
O T T E
D
:4
:2
M
U S
E R jk n ig h t
AS NOTED
D E
P A
R T
M E
N T O
F T
H E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
Y S
T E
M S C
O M
M A
N D
M
ID
L A
N T D
C C
O R
E N
A V
A L S
T A
T
IO
N -N
O R
F O
L K
V A
C U
T L E
R
M A
IN
E
N40085-19-D-9008 T008
02/08/23
PWD ME, via Email Approved by Jeffrey Hoyt, SEAL
FAD
NOT TO SCALECS507
NOT TO SCALECS507
ENTRY CONTROL POINT FENCE / RESTRICTED AREA SECURITY FENCE
- SINGLE EXTENSION ARM DETAILS
1'- 6"
6"
1'- 10"
7 1/2"
.0
LINE POST CORNER POST
PROTECTED SIDE OF FENCE (TYP)
BLIND REVET INSTALLED FROM
1/4" LARGE FLANGE STRUCTURAL
ARM (TYP)
CUT IN BARBWIRE
LOCK PIN OR Z
BARBWIRE ARM (TYP)
LOCK PIN OR Z CUT IN
STRAND (TYP)
BARBED WIRE
STRAND (TYP)
BARBED WIRE
PROTECTED SIDE OF FENCE (TYP)
BLIND REVET INSTALLED FROM
1/4" LARGE FLANGE STRUCTURAL
1. FENCE: THE FENCING MATERIAL AND INSTALLATION MUST MEET ASTM F2611-15
UNLESS OTHERWISE SPECIFIED ON THESE DRAWINGS, THE MORE STRINGENT MUST
APPLY. FOR EXAMPLE: END, CORNER, AND PULL POST DIAMETERS ARE LARGER ON
THE DRAWINGS THAN ASTM F2611-15 REQUIRES.
2. FABRIC: THE STANDARD FENCE FABRIC MUST BE VINYL, ZINC, OR
ALUMINUM-COATED STEEL WIRE CHAIN LINK WITH MESH OPENINGS NOT LARGER
THAN TWO INCHES PER SIDE AND A TWISTED AND BARBED SELVAGE AT TOP AND
BOTTOM IN ACCORDANCE WITH ASTM A392-11a FOR BASE PERIMETER OR
HEIGHTENED SECURITY ZONES. UTILIZE 6-GAUGE FOR BASE PERIMETER OR
HEIGHTENED SECURITY ZONES AND 9-GAUGE FOR BASE INTERIOR OR WHEN JOINING
AN EXISTING FENCE WHICH IS ALREADY 9-GAUGE. AFTER THE FABRIC INSTALLATION
IS COMPLETE, EXERCISE THE FABRIC BY APPLYING A 50 LB PUSH-PULL FORCE AT
THE CENTER OF THE FABRIC BETWEEN POSTS. THE USE OF A 30 LB PULL AT
THE CENTER OF THE PANEL MUST NOT CAUSE FABRIC DEFLECTION OF MORE THAN
2.5 INCHES WHEN PULLING FABRIC FROM THE POST SIDE OF THE FENCE. EVERY
SECOND PANEL MUST MEET THIS REQUIREMENT. RESECURE AND/OR ADD BRACING
AND RETEST ALL FAILED PANELS AT THE CONTRACTORS EXPENSE. (UFGS 32 31
13.53)
3. FITTINGS AND FABRIC TIES: ALL GALVANIZED FITTINGS, FABRIC TIES AND HOG RINGS
MUST CONFORM TO ASTM F626-14 AND ZINC COATED PER ASTM-A153-16a. ONLY
9-GAUGE STEEL FABRIC TIES MUST BE USED. COATING OR PLATING WILL BE
ELECTROLYTICALLY COMPATIBLE WITH THE FENCE FABRIC TO INHIBIT CORROSION.
4. TENSION WIRE: TENSION WIRES MUST BE INSTALLED ON SECURED SIDE OF THE
FENCE AND AFFIXED WITH FABRIC TIES OR HOG RINGS ALONG THE TOP & BOTTOM
OF THE FENCE FOR STABILIZATION OF THE FENCE FABRIC. METALLIC COATED
STEEL MARCELLED TENSION WIRE MUST BE 7-GAUGE MINIMUM TYPE-II CLASS 5
(2.0 OZ/SQ.FT) ZINC COATED IN ACCORDANCE WITH ASTM-A824-01. TOP AND
BOTTOM TENSION WIRE MUST BE WITHIN 8 INCHES OF THE EDGE OF FABRIC ON
THE TOP AND BOTTOM.
5. BARBED WIRE: 3 OR 6 STRANDS , WHICHEVER IS SPECIFIED, OF METALLIC COATED
STEEL BARBED WIRE MUST COMPLY WITH ASTM A121-13 DESIGN NUMBER
12-4-5-14R COATING TYPE Z CLASS 3.
6. FENCE HEIGHT
AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 OR 6 STRANDS OF BARBED WIRE,
7. GROUND CLEARANCE: BOTTOM OF THE FENCE FABRIC MUST BE WITHIN TWO
INCHES OF FIRM SOIL.
8. DOUBLE EXTENSION ARMS: A DOUBLE EXTENSION ARM IS AN OVERHANG OF
BARBED WIRED ALONG THE TOP OF A FENCE, FACING OUTWARD (AWAY FROM
PROTECTED SITE) AND UPWARD AT APPROX. 45 DEGREE ANGLE. DOUBLE
EXTENSION ARMS MUST INCREASE THE OVERALL HEIGHT OF THE FENCE AT LEAST 1
FOOT FOR A TOTAL HEIGHT OF 8 OR 10 FEET AS SHOWN. DOUBLE EXTENSION
ARMS MUST BE PERMANENTLY AFFIXED TO THE TOP OF FENCE POSTS WITH BLIND
RIVETS FROM THE PROTECTED SIDE OF THE FENCE TO AVOID TAMPERING FROM THE
ATTACK SIDE OF THE FENCE. SIX STRANDS OF 12-GAUGE BARBED WIRE, EQUALLY
SPACED, MUST BE INSTALLED ON THE DOUBLE EXTENSION ARMS.
9. FENCE POSTS, RAILS, AND BRACES: MUST BE ASTM F1043-18 GROUP IC ROUND
STEEL PIPE AND MUST BE GALVANIZED IN ACCORDANCE WITH THE SPECIFICATIONS.
SIZE (DIAMETER) MUST NOT BE LESS THAN THAT SPECIFIED BELOW. POSTS MUST
BE PLUMB IN CONCRETE FOOTING IN ACCORDANCE WITH ASTM F567-14A. TOP OF
9.1. POST SIZE:
FOOTING DIA. - 12"
CONCRETE - 4000 PSI
FOOTING DIA. - 16"
CONCRETE - 4000 PSI
FOOTING DIA. - 24"
CONCRETE - 4000 PSI
9.2 POST SPACING: FENCE POST SPACING MUST NOT EXCEED 10'-0" OC OR AS
INDICATED ON THE DRAWINGS. MAXIMUM POST SPACING OF 10'-0" OC WILL
BE STRICTLY ENFORCED. POST SPACING MUST BE SHORTENED ALONG GRADES
SUCH THAT NO MORE THAN 2'-0" OF ELEVATION CHANGE OCCURS BETWEEN
POSTS. FENCE POST SPACING AND SIZE (DIAMETER) MUST BE DETERMINED IN
10.
CHAIN LINK FENCING NOTES
8' TO 10' AND 10' TO 12' TRANSITION
- GROUNDING DETAIL
ENTRY CONTROL POINT FENCE /
RESTRICTED AREA SECURITY FENCE
FENCE POST
CLAMPS
BRONZE GROUNDING
FENCE POST WITH
ATTACH TO METAL
2'-0"
FENCE TO GROUND MUST NOT EXCEED 25 OHMS.
AND GROUND RODS. TOTAL RESISTANCE OF THE
CONTINUITY BETWEEN FENCE POSTS, FENCE FABRIC,
GROUNDING CLAMPS TO CREATE ELECTRICAL
THE FENCE AND ELECTRODES WITH BRONZE
TO ITS GATE POST. CLAMP GROUND CONNECTOR TO
BOND EACH GATE WITH A FLEXIBLE BONDING STRAP
MORE THAN 150 FT BETWEEN GROUNDING POINTS.
GROUNDING POINTS AS NECESSARY TO ENSURE NO
GATES AND AT EACH CORNER POST. ADD
GROUND FENCES ON EACH SIDE OF ALL NOTE:
NOT TO SCALECS507
ENTRY CONTROL POINT FENCE / RESTRICTED AREA SECURITY FENCE
1/4"
THICKNESS OF
WITH A MINIMUM
GROUNDING PLATE
COPPER
TWO SQUARE FOOT
EXOTHERMIC WELD
MOLDED
COPPER WIRE
#6 AWG
FINISHED GRADE
POST EMBED DEPTH - 36"
POST EMBED DEPTH - 36"
POST EMBED DEPTH - 36"
FOOTING DEPTH - 42"
FOOTING DEPTH - 42"
FOOTING DEPTH - 42"
WHICHEVER IS SPECIFIED. [10-FT TALL FENCE] CHAIN LINK FABRIC MUST BE 9'
BARBED WIRE, WHICHEVER IS SPECIFIED. [12-FT TALL FENCE] CHAIN LINK FABRIC
HIGH WITH AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 OR 6 STRANDS OF
MUST BE 11' HIGH WITH AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 OR 6
NOT TO SCALECS507
REPLACEMENT GROUNDING GRID PLAN
SUBMISSIONS:
FENCE. WHENEVER TOTAL FENCE HEIGHT EXCEEDS 8 FT A BRACE RAIL MUST BE
PLANS, HEIGHT OF FABRIC WILL ALWAYS BE 1 FT LESS THAN TOTAL HEIGHT OF
STRANDS OF BARBED WIRE, WHICHEVER IS SPECIFIED. UNLESS SHOWN HIGHER ON
ADDED IN THE MIDDLE.
WATER CROSSING:11.
HEIGHT TRANSITIONS:
12.
14.
SIGNAGE:
EXISTING GROUNDING GRID:EXISTING NO. 6 AWG BARE COPPER GROUNDING GRID IS BURIED APPROXIMATELY
3"-12" BELOW SURFACE IN THE ENTIRE SCOPE OF WORK AREA. EXISTING GROUNDING GRID WIRE IS
CONNECTED TOGETHER VIA EXOTHERMIC WELDS (CADWELD). RESTORE GROUNDING GRID AFFECTED OR
DAMAGED BY CONTRACTORS OPERATIONS. NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE OF AREAS
THAT WILL BE REPAIRED PRIOR TO COMPLETING THE REPAIR(S) AND DOCUMENT THESE LOCATIONS TO BE
INCLUDED ON THE AS-BUILT DRAWINGS.
PROVIDE SIGNAGE AND INSTALL ON OUTSIDE OF FENCE WITH HOG RINGS. THE ENTRY CONTROL
AREA MUST HAVE A "U.S. GOVERNMENT PROPERTY NO TRESPASSING" SIGN PROVIDED EVERY 200 FT.
THE ARRAY PERIMETER FENCE MUST HAVE A "WARNING RESTRICTED AREA" SIGN PROVIDED EVERY 100 FT.
REFER TO SIGNING DETAILS FOR SPECIFICS.
13. GROUNDING NOTE:GROUND FENCES ON EACH SIDE OF ALL GATES, AT EACH CORNER POST, WITHIN 50 FT
25 OHMS.
FENCE FABRIC, AND GROUNDING PLATES. TOTAL RESISTANCE OF THE FENCE TO GROUND MUST NOT EXCEED
ELECTRODES WITH BRONZE GROUNDING CLAMPS TO CREATE ELECTRICAL CONTINUITY BETWEEN FENCE POSTS, GATE WITH A FLEXIBLE BONDING STRAP TO ITS GATE POST. CLAMP GROUND CONNECTOR TO THE FENCE AND
FT MAX INTERVALS ALONG BOTH THE ENTRY CONTROL POINT AND RESTRICTED AREA FENCE. BOND EACH
OF ANY BUILDING, AT OR NEAR CROSSINGS OF ELECTRIC UTILITIES OF 600 VOLTS OR MORE, AND AT 150
15. SUBMIT SHOP DRAWINGS TO CONTRACTING OFFICER FOR APPROVAL PRIOR TO ORDERING
MATERIALS IN ACCORDANCE WITH THE SPECIFICATIONS.
CHAIN LINK FENCING NOTES (CONTINUED)
SHOWN. UTILIZE EQUAL SPACING ON THE POST.
EXTENSION ARM TO THE POST OF THE 10'/12' FENCE SECTION AS
OF BARBED WIRE FROM THE 8'/10' FENCE SECTION SINGLE
STRAIGHT RUN OF FENCE. INSTALL AN ADDITIONAL (3) STRANDS
SECTION TO THE 10'/12' SECTION SIMILAR TO ANY OTHER
CONNECT THE (3) STRANDS OF BARBED WIRE FROM THE 8'/10'
- HEIGHT TRANSITION SECTION
POST FOOTING TO BE CROWNED TO SHED WATER AWAY FROM POST.
: [8-FT TALL FENCE] CHAIN LINK FABRIC MUST BE 7' HIGH WITH
FOOTING DIA. - 12"
POST EMBED DEPTH - 36"
LINE POSTS (8' FENCE) - 2.875" OD X 0.130" WALL THICKNESS
LINE POSTS (10' FENCE) - 3.5" OD X 0.160" WALL THICKNESS
FOOTING DEPTH - 42"
CONCRETE - 4000 PSI
FOOTING DIA. - 12"
POST EMBED DEPTH - 60"
- LINE POSTS (12' FENCE) - 3.5" OD X 0.160" WALL THICKNESS
FOOTING DEPTH - 66"
CONCRETE - 4000 PSI
FOOTING DIA. - 16"
CONCRETE - 4000 PSIPOST EMBED DEPTH - 60"
FOOTING DEPTH - 66"
TERMINAL/PULL/CORNER (8' AND 10' FENCE) - 4.0" OD X 0.160" WALL THICKNESS
TERMINAL/PULL/CORNER (12' FENCE) - 4.0" OD X 0.160" WALL THICKNESS
SWING GATE POSTS - 4.0" OD X 0.160" WALL THICKNESS
FOOTING DIA. - 24"
CONCRETE - 4000 PSIPOST EMBED DEPTH - 60"
FOOTING DEPTH - 66"
SLIDING GATE POSTS - 4.0" OD X 0.160" WALL THICKNESS
9.3 FOOTING EXCAVATION:
PROVIDE WATER CROSSING WITH COMPATIBLE MARINE GRADE MATERIALS AT ALL DRAINAGE
PATHS, SWALES, OR LOW AREAS THAT EXTEND UNDER PERIMETER. THE EXISTING DRAINAGE PATH MUST NOT
BE NEGATIVELY IMPEDED.
ACCORDANCE WITH CHAIN LINK FENCE MANUFACTURER'S INSTITUTE WIND LOAD GUIDE (WLG 2445)
DIAMETER MUST NOT BE LESS THAN THAT SPECIFIED IN NOTE 9.1 ABOVE.
FENCE HEIGHT TRANSITION CAN NOT EXCEED 2 FT IN HEIGHT AT ANY TIME. REFERENCE
FENCE TRANSITION DETAIL.
WHERE BEDROCK IS ENCOUNTERED ABOVE THE BOTTOM OF FENCE/GATE POST
FOUNDATION, THE BEDROCK MUST BE REMOVED TO THE BOTTOM OF THE FOUNDATION.
CS507
JSK JSK TCW
F E
N C
IN
G
D E
T A
IL
S
12880881 99 358