CS507 - FENCING DETAILS.pdf

PDF 568 KB Posted

Attached to
P347 Perimeter Security Improvement, Portsmouth Naval Shipyard, NCTS Cutler, Maine
Solicitation number
N4008523R2539
Issued by

View the file

Other files

File Type Posted
Amendment 0012.pdf PDF
P-347 Price Proposal Form AMD 0012.pdf PDF
1614700Amend0011dwg.pdf PDF
P347 AMENDMENT 0011.pdf PDF
1614700Amend0011spc.pdf PDF
Prospect Harbor Canopy Drawings Calcs Data.pdf PDF
P347 AMENDMENT 0010.pdf PDF
P347 AMENDMENT 0009.pdf PDF
P347 J-A Interior Finishes Redacted.pdf PDF
1614700Amend0008spc.pdf PDF
P347 AMENDMENT 0008.pdf PDF
1614700Amend0008dwg.pdf PDF
P347 AMENDMENT 0007.pdf PDF
P347 AMENDMENT 0006.pdf PDF
09 26 00.pdf PDF
Uline IH-2769-SPFR.PDF PDF
08 14 00.pdf PDF
Uline IH-1119-SPFR.PDF PDF
P347 AMENDMENT 0005.pdf PDF
P347 AMENDMENT 0004.pdf PDF
1614700dwg08of22CIVIL_SIGNING_UTILITIES.pdf PDF
1614700dwg18of22FIRE.pdf PDF
1614700dwg04of22CIVIL_ALIGNMENT_DEMO.pdf PDF
1614700dwg14of22LANDSCAPING.pdf PDF
1614700dwg21of22ELECTRICAL.pdf PDF
1614700dwg15of22ENVIRONMENTAL.pdf PDF
1614700dwg01of22GENERAL.pdf PDF
1614700dwg10of22CIVIL_EROSION_02.pdf PDF
1614700dwg13of22WETLAND.pdf PDF
1614700dwg12of22CIVIL_EROSION_04.pdf PDF
1614700dwg11of22CIVIL_EROSION_03.pdf PDF
1614700spc1of1.pdf PDF
1614700dwg17of22ARCHITECTURAL_INTERIOR.pdf PDF
1614700dwg05of22CIVIL_SITE.pdf PDF
1614700dwg20of22MECHANICAL.pdf PDF
1614700dwg03of22EXISTING_CONDITION.pdf PDF
1614700dwg02of22HAZMAT_GEOTECH.pdf PDF
1614700dwg19of22PLUMBING.pdf PDF
1614700dwg09of22CIVIL_EROSION_01.pdf PDF
1614700dwg22of22TELECOM_SECURITY_AUDIO.pdf PDF
1614700dwg07of22CIVIL_GRADING_DRAINAGE_02.pdf PDF
1614700dwg06of22CIVIL_GRADING_DRAINAGE_01.pdf PDF
1614700dwg16of22STRUCTURAL.pdf PDF
P347 AMENDMENT 0003.pdf PDF
P347 AMENDMENT 0002.pdf PDF
P347 AMENDMENT 0001.pdf PDF
Cutler Site Access Requirements-NAVFAC Instructions.docx DOCX document
N4008523R2539 P347 AMENDMENT 01.pdf PDF
Cutler Site Access Requirements-Contractor Instructions.docx DOCX document
SECNAV_5512_1_dtd_May21.pdf PDF
Show 40 more

Latest 50 of 105 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

A/E INFO

N

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D M

ID

A

T L

A N

T

IC

DRAWFORM REVISION: 25 AUGUST 2020

SCALE:

EPROJECT NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A P

P R

D A

T E

D E

S C

R

IP

T

IO

N S

Y M

1614700

CRH/LAF

IM

P

R O

V E

M E

N T S

P -3

P

E R

IM

E T

E R S

E C

U R

IT

Y

EJA

DSN

F

IL

E

M E p w g f n e t p w .b e n t le y .c o m :g f n e t p w

D o c u m e n t s

P r o je c t s

C A

D D

P L

S H

E E

T S

G F

P

C S .d g n

L

Y O

U T

M E

P lo t

P L

O T T E

D

:4

:2

M

U S

E R jk n ig h t

AS NOTED

D E

P A

R T

M E

N T O

F T

H E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G S

Y S

T E

M S C

O M

M A

N D

M

ID

L A

N T D

C C

O R

E N

A V

A L S

T A

T

IO

N -N

O R

F O

L K

V A

C U

T L E

R

M A

IN

E

N40085-19-D-9008 T008

02/08/23

PWD ME, via Email Approved by Jeffrey Hoyt, SEAL

FAD

NOT TO SCALECS507

NOT TO SCALECS507

ENTRY CONTROL POINT FENCE / RESTRICTED AREA SECURITY FENCE

- SINGLE EXTENSION ARM DETAILS

1'- 6"

6"

1'- 10"

7 1/2"

.0

LINE POST CORNER POST

PROTECTED SIDE OF FENCE (TYP)

BLIND REVET INSTALLED FROM

1/4" LARGE FLANGE STRUCTURAL

ARM (TYP)

CUT IN BARBWIRE

LOCK PIN OR Z

BARBWIRE ARM (TYP)

LOCK PIN OR Z CUT IN

STRAND (TYP)

BARBED WIRE

STRAND (TYP)

BARBED WIRE

PROTECTED SIDE OF FENCE (TYP)

BLIND REVET INSTALLED FROM

1/4" LARGE FLANGE STRUCTURAL

1. FENCE: THE FENCING MATERIAL AND INSTALLATION MUST MEET ASTM F2611-15

UNLESS OTHERWISE SPECIFIED ON THESE DRAWINGS, THE MORE STRINGENT MUST

APPLY. FOR EXAMPLE: END, CORNER, AND PULL POST DIAMETERS ARE LARGER ON

THE DRAWINGS THAN ASTM F2611-15 REQUIRES.

2. FABRIC: THE STANDARD FENCE FABRIC MUST BE VINYL, ZINC, OR

ALUMINUM-COATED STEEL WIRE CHAIN LINK WITH MESH OPENINGS NOT LARGER

THAN TWO INCHES PER SIDE AND A TWISTED AND BARBED SELVAGE AT TOP AND

BOTTOM IN ACCORDANCE WITH ASTM A392-11a FOR BASE PERIMETER OR

HEIGHTENED SECURITY ZONES. UTILIZE 6-GAUGE FOR BASE PERIMETER OR

HEIGHTENED SECURITY ZONES AND 9-GAUGE FOR BASE INTERIOR OR WHEN JOINING

AN EXISTING FENCE WHICH IS ALREADY 9-GAUGE. AFTER THE FABRIC INSTALLATION

IS COMPLETE, EXERCISE THE FABRIC BY APPLYING A 50 LB PUSH-PULL FORCE AT

THE CENTER OF THE FABRIC BETWEEN POSTS. THE USE OF A 30 LB PULL AT

THE CENTER OF THE PANEL MUST NOT CAUSE FABRIC DEFLECTION OF MORE THAN

2.5 INCHES WHEN PULLING FABRIC FROM THE POST SIDE OF THE FENCE. EVERY

SECOND PANEL MUST MEET THIS REQUIREMENT. RESECURE AND/OR ADD BRACING

AND RETEST ALL FAILED PANELS AT THE CONTRACTORS EXPENSE. (UFGS 32 31

13.53)

3. FITTINGS AND FABRIC TIES: ALL GALVANIZED FITTINGS, FABRIC TIES AND HOG RINGS

MUST CONFORM TO ASTM F626-14 AND ZINC COATED PER ASTM-A153-16a. ONLY

9-GAUGE STEEL FABRIC TIES MUST BE USED. COATING OR PLATING WILL BE

ELECTROLYTICALLY COMPATIBLE WITH THE FENCE FABRIC TO INHIBIT CORROSION.

4. TENSION WIRE: TENSION WIRES MUST BE INSTALLED ON SECURED SIDE OF THE

FENCE AND AFFIXED WITH FABRIC TIES OR HOG RINGS ALONG THE TOP & BOTTOM

OF THE FENCE FOR STABILIZATION OF THE FENCE FABRIC. METALLIC COATED

STEEL MARCELLED TENSION WIRE MUST BE 7-GAUGE MINIMUM TYPE-II CLASS 5

(2.0 OZ/SQ.FT) ZINC COATED IN ACCORDANCE WITH ASTM-A824-01. TOP AND

BOTTOM TENSION WIRE MUST BE WITHIN 8 INCHES OF THE EDGE OF FABRIC ON

THE TOP AND BOTTOM.

5. BARBED WIRE: 3 OR 6 STRANDS , WHICHEVER IS SPECIFIED, OF METALLIC COATED

STEEL BARBED WIRE MUST COMPLY WITH ASTM A121-13 DESIGN NUMBER

12-4-5-14R COATING TYPE Z CLASS 3.

6. FENCE HEIGHT

AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 OR 6 STRANDS OF BARBED WIRE,

7. GROUND CLEARANCE: BOTTOM OF THE FENCE FABRIC MUST BE WITHIN TWO

INCHES OF FIRM SOIL.

8. DOUBLE EXTENSION ARMS: A DOUBLE EXTENSION ARM IS AN OVERHANG OF

BARBED WIRED ALONG THE TOP OF A FENCE, FACING OUTWARD (AWAY FROM

PROTECTED SITE) AND UPWARD AT APPROX. 45 DEGREE ANGLE. DOUBLE

EXTENSION ARMS MUST INCREASE THE OVERALL HEIGHT OF THE FENCE AT LEAST 1

FOOT FOR A TOTAL HEIGHT OF 8 OR 10 FEET AS SHOWN. DOUBLE EXTENSION

ARMS MUST BE PERMANENTLY AFFIXED TO THE TOP OF FENCE POSTS WITH BLIND

RIVETS FROM THE PROTECTED SIDE OF THE FENCE TO AVOID TAMPERING FROM THE

ATTACK SIDE OF THE FENCE. SIX STRANDS OF 12-GAUGE BARBED WIRE, EQUALLY

SPACED, MUST BE INSTALLED ON THE DOUBLE EXTENSION ARMS.

9. FENCE POSTS, RAILS, AND BRACES: MUST BE ASTM F1043-18 GROUP IC ROUND

STEEL PIPE AND MUST BE GALVANIZED IN ACCORDANCE WITH THE SPECIFICATIONS.

SIZE (DIAMETER) MUST NOT BE LESS THAN THAT SPECIFIED BELOW. POSTS MUST

BE PLUMB IN CONCRETE FOOTING IN ACCORDANCE WITH ASTM F567-14A. TOP OF

9.1. POST SIZE:

FOOTING DIA. - 12"

CONCRETE - 4000 PSI

FOOTING DIA. - 16"

CONCRETE - 4000 PSI

FOOTING DIA. - 24"

CONCRETE - 4000 PSI

9.2 POST SPACING: FENCE POST SPACING MUST NOT EXCEED 10'-0" OC OR AS

INDICATED ON THE DRAWINGS. MAXIMUM POST SPACING OF 10'-0" OC WILL

BE STRICTLY ENFORCED. POST SPACING MUST BE SHORTENED ALONG GRADES

SUCH THAT NO MORE THAN 2'-0" OF ELEVATION CHANGE OCCURS BETWEEN

POSTS. FENCE POST SPACING AND SIZE (DIAMETER) MUST BE DETERMINED IN

10.

CHAIN LINK FENCING NOTES

8' TO 10' AND 10' TO 12' TRANSITION

- GROUNDING DETAIL

ENTRY CONTROL POINT FENCE /

RESTRICTED AREA SECURITY FENCE

FENCE POST

CLAMPS

BRONZE GROUNDING

FENCE POST WITH

ATTACH TO METAL

2'-0"

FENCE TO GROUND MUST NOT EXCEED 25 OHMS.

AND GROUND RODS. TOTAL RESISTANCE OF THE

CONTINUITY BETWEEN FENCE POSTS, FENCE FABRIC,

GROUNDING CLAMPS TO CREATE ELECTRICAL

THE FENCE AND ELECTRODES WITH BRONZE

TO ITS GATE POST. CLAMP GROUND CONNECTOR TO

BOND EACH GATE WITH A FLEXIBLE BONDING STRAP

MORE THAN 150 FT BETWEEN GROUNDING POINTS.

GROUNDING POINTS AS NECESSARY TO ENSURE NO

GATES AND AT EACH CORNER POST. ADD

GROUND FENCES ON EACH SIDE OF ALL NOTE:

NOT TO SCALECS507

ENTRY CONTROL POINT FENCE / RESTRICTED AREA SECURITY FENCE

1/4"

THICKNESS OF

WITH A MINIMUM

GROUNDING PLATE

COPPER

TWO SQUARE FOOT

EXOTHERMIC WELD

MOLDED

COPPER WIRE

#6 AWG

FINISHED GRADE

POST EMBED DEPTH - 36"

POST EMBED DEPTH - 36"

POST EMBED DEPTH - 36"

FOOTING DEPTH - 42"

FOOTING DEPTH - 42"

FOOTING DEPTH - 42"

WHICHEVER IS SPECIFIED. [10-FT TALL FENCE] CHAIN LINK FABRIC MUST BE 9'

BARBED WIRE, WHICHEVER IS SPECIFIED. [12-FT TALL FENCE] CHAIN LINK FABRIC

HIGH WITH AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 OR 6 STRANDS OF

MUST BE 11' HIGH WITH AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 OR 6

NOT TO SCALECS507

REPLACEMENT GROUNDING GRID PLAN

SUBMISSIONS:

FENCE. WHENEVER TOTAL FENCE HEIGHT EXCEEDS 8 FT A BRACE RAIL MUST BE

PLANS, HEIGHT OF FABRIC WILL ALWAYS BE 1 FT LESS THAN TOTAL HEIGHT OF

STRANDS OF BARBED WIRE, WHICHEVER IS SPECIFIED. UNLESS SHOWN HIGHER ON

ADDED IN THE MIDDLE.

WATER CROSSING:11.

HEIGHT TRANSITIONS:

12.

14.

SIGNAGE:

EXISTING GROUNDING GRID:EXISTING NO. 6 AWG BARE COPPER GROUNDING GRID IS BURIED APPROXIMATELY

3"-12" BELOW SURFACE IN THE ENTIRE SCOPE OF WORK AREA. EXISTING GROUNDING GRID WIRE IS

CONNECTED TOGETHER VIA EXOTHERMIC WELDS (CADWELD). RESTORE GROUNDING GRID AFFECTED OR

DAMAGED BY CONTRACTORS OPERATIONS. NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE OF AREAS

THAT WILL BE REPAIRED PRIOR TO COMPLETING THE REPAIR(S) AND DOCUMENT THESE LOCATIONS TO BE

INCLUDED ON THE AS-BUILT DRAWINGS.

PROVIDE SIGNAGE AND INSTALL ON OUTSIDE OF FENCE WITH HOG RINGS. THE ENTRY CONTROL

AREA MUST HAVE A "U.S. GOVERNMENT PROPERTY NO TRESPASSING" SIGN PROVIDED EVERY 200 FT.

THE ARRAY PERIMETER FENCE MUST HAVE A "WARNING RESTRICTED AREA" SIGN PROVIDED EVERY 100 FT.

REFER TO SIGNING DETAILS FOR SPECIFICS.

13. GROUNDING NOTE:GROUND FENCES ON EACH SIDE OF ALL GATES, AT EACH CORNER POST, WITHIN 50 FT

25 OHMS.

FENCE FABRIC, AND GROUNDING PLATES. TOTAL RESISTANCE OF THE FENCE TO GROUND MUST NOT EXCEED

ELECTRODES WITH BRONZE GROUNDING CLAMPS TO CREATE ELECTRICAL CONTINUITY BETWEEN FENCE POSTS, GATE WITH A FLEXIBLE BONDING STRAP TO ITS GATE POST. CLAMP GROUND CONNECTOR TO THE FENCE AND

FT MAX INTERVALS ALONG BOTH THE ENTRY CONTROL POINT AND RESTRICTED AREA FENCE. BOND EACH

OF ANY BUILDING, AT OR NEAR CROSSINGS OF ELECTRIC UTILITIES OF 600 VOLTS OR MORE, AND AT 150

15. SUBMIT SHOP DRAWINGS TO CONTRACTING OFFICER FOR APPROVAL PRIOR TO ORDERING

MATERIALS IN ACCORDANCE WITH THE SPECIFICATIONS.

CHAIN LINK FENCING NOTES (CONTINUED)

SHOWN. UTILIZE EQUAL SPACING ON THE POST.

EXTENSION ARM TO THE POST OF THE 10'/12' FENCE SECTION AS

OF BARBED WIRE FROM THE 8'/10' FENCE SECTION SINGLE

STRAIGHT RUN OF FENCE. INSTALL AN ADDITIONAL (3) STRANDS

SECTION TO THE 10'/12' SECTION SIMILAR TO ANY OTHER

CONNECT THE (3) STRANDS OF BARBED WIRE FROM THE 8'/10'

- HEIGHT TRANSITION SECTION

POST FOOTING TO BE CROWNED TO SHED WATER AWAY FROM POST.

: [8-FT TALL FENCE] CHAIN LINK FABRIC MUST BE 7' HIGH WITH

FOOTING DIA. - 12"

POST EMBED DEPTH - 36"

LINE POSTS (8' FENCE) - 2.875" OD X 0.130" WALL THICKNESS

LINE POSTS (10' FENCE) - 3.5" OD X 0.160" WALL THICKNESS

FOOTING DEPTH - 42"

CONCRETE - 4000 PSI

FOOTING DIA. - 12"

POST EMBED DEPTH - 60"

- LINE POSTS (12' FENCE) - 3.5" OD X 0.160" WALL THICKNESS

FOOTING DEPTH - 66"

CONCRETE - 4000 PSI

FOOTING DIA. - 16"

CONCRETE - 4000 PSIPOST EMBED DEPTH - 60"

FOOTING DEPTH - 66"

TERMINAL/PULL/CORNER (8' AND 10' FENCE) - 4.0" OD X 0.160" WALL THICKNESS

TERMINAL/PULL/CORNER (12' FENCE) - 4.0" OD X 0.160" WALL THICKNESS

SWING GATE POSTS - 4.0" OD X 0.160" WALL THICKNESS

FOOTING DIA. - 24"

CONCRETE - 4000 PSIPOST EMBED DEPTH - 60"

FOOTING DEPTH - 66"

SLIDING GATE POSTS - 4.0" OD X 0.160" WALL THICKNESS

9.3 FOOTING EXCAVATION:

PROVIDE WATER CROSSING WITH COMPATIBLE MARINE GRADE MATERIALS AT ALL DRAINAGE

PATHS, SWALES, OR LOW AREAS THAT EXTEND UNDER PERIMETER. THE EXISTING DRAINAGE PATH MUST NOT

BE NEGATIVELY IMPEDED.

ACCORDANCE WITH CHAIN LINK FENCE MANUFACTURER'S INSTITUTE WIND LOAD GUIDE (WLG 2445)

DIAMETER MUST NOT BE LESS THAN THAT SPECIFIED IN NOTE 9.1 ABOVE.

FENCE HEIGHT TRANSITION CAN NOT EXCEED 2 FT IN HEIGHT AT ANY TIME. REFERENCE

FENCE TRANSITION DETAIL.

WHERE BEDROCK IS ENCOUNTERED ABOVE THE BOTTOM OF FENCE/GATE POST

FOUNDATION, THE BEDROCK MUST BE REMOVED TO THE BOTTOM OF THE FOUNDATION.

CS507

JSK JSK TCW

F E

N C

IN

G

D E

T A

IL

S

12880881 99 358