1614700dwg18of22FIRE.pdf

PDF 2 MB Posted

Attached to
P347 Perimeter Security Improvement, Portsmouth Naval Shipyard, NCTS Cutler, Maine
Solicitation number
N4008523R2539
Issued by

View the file

Other files

File Type Posted
Amendment 0012.pdf PDF
P-347 Price Proposal Form AMD 0012.pdf PDF
1614700Amend0011dwg.pdf PDF
P347 AMENDMENT 0011.pdf PDF
1614700Amend0011spc.pdf PDF
Prospect Harbor Canopy Drawings Calcs Data.pdf PDF
P347 AMENDMENT 0010.pdf PDF
P347 AMENDMENT 0009.pdf PDF
P347 J-A Interior Finishes Redacted.pdf PDF
1614700Amend0008spc.pdf PDF
P347 AMENDMENT 0008.pdf PDF
1614700Amend0008dwg.pdf PDF
P347 AMENDMENT 0007.pdf PDF
P347 AMENDMENT 0006.pdf PDF
09 26 00.pdf PDF
Uline IH-2769-SPFR.PDF PDF
08 14 00.pdf PDF
Uline IH-1119-SPFR.PDF PDF
P347 AMENDMENT 0005.pdf PDF
CS507 - FENCING DETAILS.pdf PDF
P347 AMENDMENT 0004.pdf PDF
1614700dwg08of22CIVIL_SIGNING_UTILITIES.pdf PDF
1614700dwg04of22CIVIL_ALIGNMENT_DEMO.pdf PDF
1614700dwg14of22LANDSCAPING.pdf PDF
1614700dwg21of22ELECTRICAL.pdf PDF
1614700dwg15of22ENVIRONMENTAL.pdf PDF
1614700dwg01of22GENERAL.pdf PDF
1614700dwg10of22CIVIL_EROSION_02.pdf PDF
1614700dwg13of22WETLAND.pdf PDF
1614700dwg12of22CIVIL_EROSION_04.pdf PDF
1614700dwg11of22CIVIL_EROSION_03.pdf PDF
1614700spc1of1.pdf PDF
1614700dwg17of22ARCHITECTURAL_INTERIOR.pdf PDF
1614700dwg05of22CIVIL_SITE.pdf PDF
1614700dwg20of22MECHANICAL.pdf PDF
1614700dwg03of22EXISTING_CONDITION.pdf PDF
1614700dwg02of22HAZMAT_GEOTECH.pdf PDF
1614700dwg19of22PLUMBING.pdf PDF
1614700dwg09of22CIVIL_EROSION_01.pdf PDF
1614700dwg22of22TELECOM_SECURITY_AUDIO.pdf PDF
1614700dwg07of22CIVIL_GRADING_DRAINAGE_02.pdf PDF
1614700dwg06of22CIVIL_GRADING_DRAINAGE_01.pdf PDF
1614700dwg16of22STRUCTURAL.pdf PDF
P347 AMENDMENT 0003.pdf PDF
P347 AMENDMENT 0002.pdf PDF
P347 AMENDMENT 0001.pdf PDF
Cutler Site Access Requirements-NAVFAC Instructions.docx DOCX document
N4008523R2539 P347 AMENDMENT 01.pdf PDF
Cutler Site Access Requirements-Contractor Instructions.docx DOCX document
SECNAV_5512_1_dtd_May21.pdf PDF
Show 40 more

Latest 50 of 105 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CD

CD

FIRE ALARM SYSTEM GENERAL NOTES: FIRE ALARM LEGEND:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

GENERAL SCOPE - PROVIDE AN ADDRESSABLE, INTELLIGENT FIRE ALARM SYSTEM IN THE VISITOR CONTROL CENTER (BUILDING 129). PROVIDE AN ADDRESSABLE NETWORKED SIMPLEX FIRE ALARM CONTROL PANEL AND

KINGFISHER KFAPT ADDRESSABLE TRANSMITTER IN THE INSPECTION STATION.

APPLICABLE CODES:

NFPA 70 NATIONAL ELECTRIC CODE (NEC), 2020

NFPA 72 NATIONL FIRE ALARM AND SIGNALING CODE, 2019.

DEVICES MUST BE UL LISTED.

SIGNALING LINE, INITIATING DEVICE, AND NOTIFICATION APPLIANCE CIRCUITS MUST BE CLASS B.

CONDUIT AND BACK BOXES MUST BE CONCEALED UNLESS OTHERWISE NOTED. JUNCTION BOXES AND COVERS MUST BE PAINTED RED IN UNFINISHED AREAS. IN FINISHED AREAS, CONDUIT AND JUNCTION BOXES MUST BE PAINTED TO MATCH THE ROOM FINISH. JUNCTION BOXES MUST HAVE A PERMANENT, MACHINE PRINTED LABEL READING "FIRE ALARM CIRCUIT" ON THE INSIDE COVER. FIRE ALARM CONDUITS IN FINISHED AREAS MUST BE MARKED WITH 3/4-IN RED BANDS EVERY 10-FT, AT EACH SIDE OF A FLOOR, WALL, OR CEILING

PENETRATION.

SYSTEM POWER AND GROUND CIRCUITS MUST BE TYPE "THHN" SOLID COPPER SIZED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS AND THE APPLICABLE CODES AND BE INSTALLED IN EMT TYPE

CONDUIT.

WIRING, CABLES, BOXES, TROUGHS AND OTHER RELATED EQUIPMENT MUST BE INSTALLED IN STRICT

COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE (NEC).

MANUAL FIRE ALARM STATIONS MUST BE DOUBLE-ACTION TYPE AND SURFACE MOUNTED IN FINISHED SPACES.

WALL-MOUNTED VISIBLE AND AUDIBLE/VISIBLE ALARM NOTIFICATION APPLIANCES MUST BE MOUNTED 90-IN ABOVE THE FINISHED FLOOR MEASURED TO THE BOTTOM OF THE LENS, OR 6-IN BELOW THE CEILING

MEASURED TO THE TOP OF THE LENS (WHICH EVER IS LOWER).

VISUAL FIRE ALARM APPLIANCES MUST HAVE A WHITE HOUSING, AND BE MARKED "ALERT."

SYNCHRONIZE VISIBLE NOTIFICATION APPLIANCES WITHIN A COMMON VIEWING AREA IN ACCORDANCE WITH

NFPA 72.

25% SPARE CAPACITY MUST BE PROVIDED ON POWER SUPPLIES AND INDIVIDUAL CIRCUITS.

SECONDARY POWER SUPPLY MUST BE VIA BATTERY CAPABLE OF THE FOLLOWING: THE FIRE ALARM SYSTEM ON STANDBY FOR 48 HOURS FOLLOWED BY 15 MINUTES IN ALARM; CHARGING AND METERING MUST BE

PROVIDED IN ACCORDANCE WITH NFPA 72.

DEDICATED BATTERY CABINETS MUST BE MOUNTED NO MORE THAN 3 FEET FROM THE FINISHED FLOOR.

DRAWINGS ARE CONCEPTUAL IN NATURE, THEY DO NOT SHOW THE EXACT LOCATIONS OF COMPONENTS NOR SHOW ALL SYSTEM COMPONENTS. CONTRACTOR MUST PROVIDE ADDITIONAL COMPONENTS FOR A PROPERLY

INSTALLED AND FUNCTIONAL SYSTEM IN ACCORDANCE WITH ALL APPLICABLE CODES.

FIRE ALARM CONTROL PANEL

KINGFISHER KFAPT RADIO ALARM TRANSMITTER

REMOTE ANNUNCIATOR

FIRE ALARM CONTROL PANEL - DEMOLISHED

CEILING-MOUNTED COMBINATION HORN/CLEAR STROBE

(SUPERSCRIPT INDICATES CANDELA RATING)

WALL-MOUNTED COMBINATION HORN/CLEAR STROBE

(SUPERSCRIPT INDICATES CANDELA RATING)

CEILING-MOUNTED STROBE

(SUPERSCRIPT INDICATES CANDELA RATING)

WALL-MOUNTED HORN/STROBE - DEMOLISHED

WALL-MOUNTED STROBE - DEMOLISHED

MANUAL PULL STATION

AREA SMOKE DETECTOR

HEAT DETECTOR

CARBON MONOXIDE DETECTOR

CONTROL MODULE

MANUAL PULL STATION - DEMOLISHED

SMOKE DETECTOR - DEMOLISHED

LOW FREQUENCY

SOUNDER BASE

WEATHERPROOF

CD

LF

SB

WP

CM

FIRE ALARM SYSTEM DEMOLITION NOTES:

1.

2.

3.

4.

THE EXISTING FIRE ALARM SYSTEM AND ASSOCIATED CONDUIT AND WIRING MUST BE DEMOLISHED

THROUGHOUT THE VISITOR CONTROL CENTER (BUILDING 129).

THE EXISTING FIRE ALARM SYSTEM AND ASSOCIATED CONDUIT AND WIRING MUST BE DEMOLISHED

THROUGHOUT BUILDING 130.

THE EXISTING KINGFISHER KFAPT ADDREASSBLE TRANSMITTER AND ASSOCAITED CONDUIT AND

WIRING MUST BE DEMOLISHED IN BUILDING 130.

SURFACES DAMAGED DURING THE DEMOLITION OF THE FIRE ALARM SYSTEM IN BUILDING 129

MUST BE REPAIRED.

ANN

FACP

RAT

P

FACP

P Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

FA001

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

F

IR

E A

LA

R

M G

E N

E R

A L

N O

T E

S A

N D

L E

G E

N D

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

F A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

273 358

12881055

F A

C P

P

P

P

P FACP

GENERAL SHEET NOTES

1. SEE SHEET FA001 FOR FIRE ALARM DEMOLITION GENERAL NOTES

AND LEGEND.

2. VISITOR CONTROL CENTER (BULIDING 129) IS PROTECTED BY AN

EXISTING NOTIFIER SFP-5UD FIRE ALARM CONTROL PANEL. THIS

EXISTING FIRE ALARM CONTROL PANEL INTERFACES WITH THE

EXSTING FIRE ALARM SYSTEM IN BUILDING 130 VIA EXSITING

MODULES CONNECTED TO THE EXISTING BUILDING 130 SLC LOOP.

3. BUILDING 130 IS PROTECTED BY AN EXISTING SIMPLEX 4100ES

ADDRESSABLE FIRE ALARM CONTROL PANEL. THIS EXISTING FIRE

ALARM CONTROL PANEL ALSO SERVES BUILDINGS 134 & 135.

BUILDINGS 134 & 135 ARE PROTECTED BY EXISTING INITIATING

DEVICES CONNECTED TO THE EXISTING BUILDING 130 SLC LOOP.

EACH BUILDING IS ALSO PROVIDED WITH AN EXISTING REMOTE

ANNUNCIATOR AND AN EXISTING NOTIFICATION APPLIANCE

BOOSTER PANEL WITH EXISTING NOTIFICATION APPPLIANCES.

4. THE EXISTING SIMPLEX FIRE ALARM CONTROL PANEL IN BUILDING

130 IS PART OF AN EXISTING NETWORKED SIMPLEX FIRE ALARM

SYSTEM SERVING THE BASE WHICH CONSISTS OF THE FOLLOWING

EXSTING NODES:

A. NODE 1: BUILDING 130 - BASE SECURITY

B. NODE 2: BUILDING 100 - OPERATIONS BUILDING

C. NODE 3: BUILDING 103 - POWER PLANT

D. NODE 4: BUILDING 123 - FIRE PROTECTION PUMP HOUSE

E. NODE 5: BUILDING 101 - SOUTH HELIX HOUSE

F. NODE 6: BUILDING 102 - NORTH HELIX HOUSE

5. THE EXISTING SIMPLEX FIRE ALARM CONTROL PANEL IN BUILDING

130 REPORTS SIGNALS FROM THE BASE TO THE LOCAL FIRE

DEPARTMENT AND NORFOLK CENTRAL DISPATCH. REPORTING TO

THE FIRE DEPARTMENT IS VIA A KINGFISHER KFAPT ADDRESSABLE

TRANSMITTER. REPORTING TO NORFOLK CENTRAL DISPATCH IS VIA

PS-NET FIBER OPTIC CONNECTION. FIRE ALARM SIGNALS ARE ALSO

SENT TO THE BASE DISPATCH.

SHEET KEYNOTES

1. THE FOLLOWING CONNECTIONS MUST BE DISCONNECTED FROM

THE EXISTING SIMPLEX FIRE ALARM CONTROL PANEL IN BUILDING

130 AND RELOCATED TO THE SIMPLEX FIRE ALARM CONTROL

PANEL IN THE INSPECTION STATION:

A. THE SLC LOOP SERVING BUILDINGS 129, 134, & 135.

B. THE NETWORK CONNECTION FOR NODE 1.

C. THE PS-NET FIBER CONNECTION FOR REPORTING TO

NORFOLK CENTRAL DISPATCH.

2. THE EXISTING FIRE ALARM CONTROL PANEL IN THE VISITOR

CONTROL CENTER (BUILDING 129) MUST BE DISCONNECTED FROM

THE EXISTING BUILDING 130 SLC LOOP. THE EXISTING INTERFACE

MUST BE DEMOLISHED AND THE EXISTING SLC LOOP MUST BE

REPAIRED SO THAT IT IS CONTINUOUS.

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

FD101

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

F

IR

E A

LA

R

M D

E M

O

LI

TI

O

N P

LA

N

S

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

F D

SCALE: 1/4" = 1'-0"

FIRE ALARM DEMOLITION PLAN - VISITOR CONTROL CENTER

PLAN

NORTH

2' 4' 8'0' 1/4" =1'-0"

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0"

FIRE ALARM DEMOLITION PLAN - BUILDING 130

PLAN

NORTH

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

274 358

12881056

P

P

P

SB

A N

N

FACP

P

C M

C M

CM

R E

F

LF

WP

15 cd 15 cd

15 cd

15 cd

30 cd

15 cd

30 cd

15 cd

15 cd

15 cd 15 cd

15 cd

15 cd

15 cd

15 cd

1 2

VESTIBULE

TOILET

BREAKROOM

MUD ROOM

SIPRNET

EXIST

OFFICE

ADMIN/COPY

ID/CHECK-IN

HALLWAY

WAITING

TOILET

LAUNDRY

MOTHER'S

SHOWER

114 COMM

OFFICE

MECH/ELEC

INTERVIEW

HALLWAY

HALLWAY

LOCKER ROOM

HALLWAY

DAYROOM

JANITOR

SHEET KEYNOTES

1. PROVIDE CONTROL MODULE FOR ACTIVATION OF EGRESS LIGHTING

UPON ALARM SIGNAL.

2. THE FIRE ALARM CONTROL PANEL MUST BE INTERFACED WITH THE

INSPECTION STATION SIMPLEX FIRE ALARM CONTROL PANEL SO

THAT IT REPORTS USING THE KINGFISHER KFAPT ADDRESSABLE

TRANSMITTER AND THE PS-NET FIBER CONNECTION.

GENERAL SHEET NOTES

1. SEE SHEET FA001 FOR FIRE ALARM GENERAL NOTES AND LEGEND.

2. IF THE FIRE ALARM SYSTEM PROVIDED THROUGHOUT THE BUILDING IS

BY SIMPLEX, THE FIRE ALARM CONTROL PANEL MUST BE CAPABLE OF

BEING CONNECTED TO THE EXISTING NETWORKED SIMPLEX FIRE

ALARM SYSTEM. IF THE FIRE ALARM SYSTEM PROVIDED THROUGHOUT

THE BUILDING IS NOT BY SIMPLEX, THE SYSTEM MUST BE INTERFACED

WITH THE SIMPLEX FIRE ALARM CONTROL PANEL IN THE INSPECTION

STATION (BUILDING 130).

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

FA101

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

F

IR

E A

LA

R

M P

LA

N

V

IS

IT

O R

C O

N

TR

O L

C E

N

TE

R

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

F A

PLAN

NORTH

SCALE: 1/4" = 1'-0"

FIRE ALARM PLAN - VISITOR CONTROL CENTER

2' 4' 8'0' 1/4" =1'-0"

GRAPHIC SCALE(S)

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

275 358

12881057

F A

C P

R A

T

B D E

A C

MECH/ELEC

STOR/JAN

109BREAKROOM

CORR

WAITING

RFI/SECURE ROOM

INSPECTION OFFICE

COMM

RESTROOM

STORAGE

GENERAL SHEET NOTES

1. SEE SHEET FA001 FOR FIRE ALARM GENERAL NOTES AND LEGEND.

2. THE SIMPLEX FIRE ALARM CONTROL PANEL MUST BE PART OF THE

EXISTING NETWORKED SIMPLEX FIRE ALARM SYSTEM SERVING

THE BASE WHICH CONSISTS OF THE FOLLOWING EXISTING NODES:

A. NODE 1: INSPECTION STATION

B. NODE 2: BUILDING 100 - OPERATIONS BUILDING

C. NODE 3: BUILDING 103 - POWER PLANT

D. NODE 4: BUILDING 123 - FIRE PROTECTION PUMP HOUSE

E. NODE 5: BUILDING 101 - SOUTH HELIX HOUSE

F. NODE 6: BUILDING 102 - NORTH HELIX HOUSE

3. THE SIMPLEX FIRE ALARM CONTROL PANEL IN THE INSEPCTION

STATION MUST REPORT SIGNALS FROM THE BASE TO THE LOCAL

FIRE DEPARTMENT AND NORFOLK CENTRAL DISPATCH. REPORTING

TO THE FIRE DEPARTMENT MUST BE VIA KINGFISHER KFAPT RADIO

TRANSMITTER. REPORTING TO THE NORFOLK CENTRAL DISPATCH

MUST BE VIA PS-NET FIBER OPTIC CONNECTION. FIRE ALARM

SIGNALS MUST ALSO BE SENT TO THE BASE DISPATCH.

SHEET KEYNOTES

1. COORDINATE LOCATION OF THE SIMPLEX FIRE ALARM CONTROL

PANEL WITH THE WINDOWS. THE FOLLOWING CONNECTIONS

MUST BE RECONNECTED TO THE SIMPLEX FIRE ALARM CONTROL

PANEL:

A. THE EXISTING SLC LOOP SERVING BUILDINGS 134 & 135.

B. THE NETWORK CONNECTION FOR NODE 1.

C. THE PS-NET FIBER CONNECTION FOR REPORTING TO

NORFOLK CENTRAL DISPATCH.

2. PROVIDE SMOKE DETECTOR WITH LOCAL TEMPORAL 3 ALARM.

3. PROVIDE CARBON MONOXIDE DETECTOR WITH LOCAL TEMPORAL

4 ALARM.

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EA

LTHOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:0

:3

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_

IS

F

IR

E

R

.r v t

FA102

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

F

IR

E A

LA

R

M P

LA

N

IN

S P

E C

TI

O

N S

TA

TI

O N

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

F A

SCALE: 1/8" = 1'-0"

FIRE ALARM PLAN - INSPECTION STATION

4' 8' 16'0' 1/8" =1'-0"

PLAN

NORTH

GRAPHIC SCALE(S)

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

276 358

12881058

3-FT MIN

4-IN MIN

5-FT MAX

4-

IN

M

IN

-I

N M

A X

-I

N M

A X

FIRE ALARM

PULL DOWN

FIREFIRE

SYNCHRONIZE MORE

THAN TWO APPLIANCES

IN ANY FIELD OF VIEW.

NOTE: MEASUREMENTS

SHOWN ARE TO THE

CLOSEST POINT ON THE

DETECTOR.

A/C SUPPLY

DIFFUSER

CEILING

SIDE WALL

48-INCH

90-INCH

FINISHED

FLOOR

MANUAL

PULL

STATION

AUDIO/VISUAL

& VISUAL-ONLY

DEVICES

CEILING MOUNTED

SMOKE DETECTOR

FINISHED

WALL

HEAT DETECTOR

ACCEPTED HERE

HEAT DETECTOR

PROHIBITED HERE

HEAT DETECTOR

ACCEPTED HERE

SIDE WALL

FINISHED

WALL

SMOKE DETECTOR

ACCEPTED HERE

T-BAR

DROP TILE

CEILING GRID

T-BAR

CLIP

DROP CEILING TILE

ELECTRICAL

BACK BOX

DO NOT INSTALL WITHIN 3' OF ANY

HVAC SUPPLY/RETURN DIFFUSER OR

TIP OF CEILING FAN BLADE.

FACP

P

SS

ANN

EOLR

EOLR

120-VAC

CM

153015

EGRESS

LIGHTING

ACTIVATION

SS TO INSPECTION STATION

MANUAL PULL STATION

O P

ER

A

TIO

N

A

LA

R M

C O N D

IT

IO

N A

T F A C P

TR

O U

BLE

C O N D

IT

IO

N A

T F

AC

P

TR

A N S M

IT

A

LA

R M

S

IG

N A L

TO

F

A C

P IN

IN

S

PEC

TIO

N S

TA

TIO

N

OTHER TROUBLE CONDITION

FIRE ALARM INPUT

AREA SMOKE DETECTOR ACTIVATION

TR

A N S M

IT

T

R O U

BLE

S

IG

N A L

TO

F

A C P

IN

IN

SP

EC

TIO

N S

TA

TIO

N

FACP CIRCUIT FAULT (OPEN, GROUND, SHORT)

A C

TIV

A

TE N

O

TIF

IC

A

TIO

N A

P

PLI

A N C

ES -

FIR

E A

LA

R M

E

VA

C U A

TIO

N

CARBON MONOXIDE DETECTOR ACTIVATION

A C

TIV

A

TE N

O

TIF

IC

A

TIO

N A

P

PLI

A N C

ES -

C A R

BO

N M

O N O

XID

E E

VA

C U A

TIO

N

A C

TIV

A

TE E

G R

ES

S L

IG

H

TIN

G

T-BAR CLIP

SUSPENDED CEILING PANEL

4-INCH X 4-INCH

SQUARE CONDUIT BOX

STROBES AND HORN/STROBES MUST BE INSTALLED

WHERE INDICATED ON THE FIRE ALARM PLANS.

THE ELECTRICAL CONTRACTOR MUST PROVIDE

THE NECESSARY MOUNTING HARDWARE TO ACHIEVE

THIS PURPOSE.

T-BAR

SUSPENDED PANEL

CEILING GRID

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:5

:0

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_ V

C F

IR

E

R

.r v t

FA501

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

F

IR

E A

LA

R

M D

E

TA

IL

S

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

F A

SCALE: NOT TO SCALE

TYPICAL DEVICE MOUNTING HEIGHTS

SCALE: NOT TO SCALE

TYPICAL SMOKE DETECTOR MOUNTING DETAIL

SCALE: NOT TO SCALE

FIRE ALARM RISER DIAGRAM - VISITOR CONTROL CENTER

SCALE: NOT TO SCALE

FIRE ALARM SEQUENCE OF OPERATIONS - VISITOR CONTROL CENTER

SCALE: NOT TO SCALE

TYPICAL HORN/STROBE MOUNTING DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

277 358

12881059

O

ER

A

TIO

N

A

LA

R M

C O N D

IT

IO

N A

T F A C P

TR

O U

BLE

C O N D

IT

IO

N A

T F

AC

P

TR

AN

S M

IT

S

IG

N A L

TO

L

O C

AL

FIR

E D

E

PAR

TM

EN

T

OTHER TROUBLE CONDITION

FIRE ALARM INPUT

HEAT DETECTOR ACTIVATION

TR

A N S M

IT

S

IG

N A L

TO

N

O R

FO

LK

C

EN

TR

A L

D

IS

P A

TC

H

FACP CIRCUIT FAULT (OPEN, GROUND, SHORT)

A C

TIV

A

TE L

O C A L

SM

O

KE A

LA

R M

CARBON MONOXIDE DETECTOR ACTIVATION

A C

TIV

A

TE L

O C A L

C A R

BO

N M

O N O

XID

E A

LA

R M

TR

A N S M

IT

S

IG

N A L

TO

B

A

SE

D

IS

P A

TC

H

ALARM SIGNAL FROM BUILDINGS 134 & 135

SUPERVISORY SIGNAL FROM BUILDING 134 & 135

TROUBLE SIGNAL FROM BUILDING 134 & 135

SU

PE

R

VIS

O R Y C

O N D

IT

IO

N A

T F A C P

ALARM SIGNAL FROM VISITOR CONTROL CENTER

TROUBLE SIGNAL FROM VISITOR CONTROL CENTER

SIGNAL FROM NETWORKED FACP

AREA SMOKE DETECTOR ACTIVATION

FACP

SS120-VAC

RAT

TO BASE DISPATCH

FROM VISITOR CONTROL CENTERFROM BUILDINGS 134 & 145

TO NORFOLK CENTRAL DISPATCH

FACP

SIMPLEX

FACP

NODE 1:

INSPECTION

STATION

(E) SIMPLEX

FACP NODE 2:

BUILDING 100 -

OPERATIONS

BUILDING

FACP

(E) SIMPLEX

FACP NODE 3:

BUILDING 103 -

POWER

PLANT

FACP

(E) SIMPLEX

FACP NODE 4:

BUILDING 123 -

FIRE PROTECTION

PUMP HOUSE

FACP

(E) SIMPLEX

FACP NODE 5:

BUILDING 101 -

SOUTH HELIX

HOUSE

FACP

(E) SIMPLEX

FACP NODE 6:

BUILDING 102 -

NORTH HELIX

HOUSE

FIRE ALARM SYSTEM NETWORK CONNECTION

SS SS

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EA

LTHOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

9 MAR 2023

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

TI

C

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K V

A

AS NOTED

F

IL

E N

A M

E

L A

Y O

U T

N A

M E

P

L O

T T

E D

U

S E

R

4445 CORPORATION LN,STE 211

VIRGINIA BEACH, VA 23462

(757) 213 - 6856

/7

/2

:0

:3

A M

B

IM

/N

A V

F A

C P

-3

P e ri m e te r S e c u ri ty

I m p ro v e m e n ts

W

P

C u tl e r_

IS

F

IR

E

R

.r v t

FA502

P -3

P

E R

IM

E

TE

R

S E

C U

R

IT

Y

IM

P

R O

V E

M E

N

TS

F

IR

E A

LA

R

M D

E

TA

IL

S

AJWAPF AHE

02/08/23

Approved by Jeffrey Hoyt, PWD ME, via Email

CRH/LAF

1614700

N40085-19-D-9008 T008

C U

T

LE

R , M

A

IN

E

EJA

DSN

DSN

M

ID

L A

N T

D C

C O

R E

F A

SCALE: NOT TO SCALE

FIRE ALARM SEQUENCE OF OPERATIONS - INSPECTION STATION

SCALE: NOT TO SCALE

FIRE ALARM RISER DIAGRAM - INSPECTION STATION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

278 358

12881060

FIRE ALARM
273-FA001 - FIRE ALARM GENERAL NOTES AND LEGEND
274-FD101 - FIRE ALARM DEMOLITION PLANS
275-FA101 - FIRE ALARM PLAN - VISITOR CONTROL CENTER
276-FA102 - FIRE ALARM PLAN - INSPECTION STATION
277-FA501 - FIRE ALARM DETAILS
278-FA502 - FIRE ALARM DETAILS
2023-03-16T21:42:48-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:05-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:07-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:08-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:09-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:11-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:23-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:40-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:42-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:43-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:44-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2023-03-16T21:43:46-0400
Norfolk, VA
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .