P-1395-E-Revision 1_2020-08-05.pdf

PDF 6 MB Posted

Attached to
P1395 SOF MARINE RAIDER REGIMENT HQ, MCAS, CAMP LEJEUNE
Solicitation number
N40085-19-R-9148
Issued by

About this file

This federal solicitation is seeking proposals for the construction of Marine Raider Regiment Headquarters facilities at Marine Corps Air Station Camp Lejeune. The scope of work includes constructing 2,788 square meters of single-story steel frame buildings with brick veneer and metal roofs, as well as miscellaneous supporting structures, utilities, parking, roadways, sidewalks, running trails and site work. Special construction features are required for soil surcharge loads and stormwater management. Electrical, mechanical, information, and site work systems will be provided. The Department of Defense and federal sustainability requirements must be followed. Proposals are solicited from contractors by the Naval Facilities Engineering Command on behalf of the Department of the Navy.

View the file

Other files

File Type Posted
C-514.pdf PDF
CG103.pdf PDF
CE106.pdf PDF
C-513.pdf PDF
CG107.pdf PDF
CD04-20201022 GER P1395 Marine Raider Bn HQS R4 -ALZ Sealed.pdf PDF
CG108.pdf PDF
REVISION 001.pdf PDF
B-104.pdf PDF
C-507.pdf PDF
B-103.pdf PDF
B-102.pdf PDF
CE103.pdf PDF
B-101.pdf PDF
C-515.pdf PDF
CE102.pdf PDF
AMENDMAENT 0004 FOR P1395.pdf PDF
01 30 01.00 22.pdf PDF
P1395 08052020 Arch Revisions.pdf PDF
20_0622_P1395_Marine-Raider_HQ_FInal_Interior_Sheets.pdf PDF
P1395 AMENDMENT 0003.pdf PDF
P1395 MARINE RAIDER FF-E Est Cost Summary_FINAL_20_0810.pdf PDF
09 69 13.pdf PDF
Part 1-P1395 BVD Request for Pricing Bid Form Spreadsheet.pdf PDF
UPDATED P1395 BID SCHEDULE.pdf PDF
P1395 PPI LOG 03.pdf PDF
AMENDMENT 0002 FOR P1395.pdf PDF
PPI LOG 02 Document..pdf PDF
P1395 SOF PPIs LOG 01.pdf PDF
10 51 00.pdf PDF
13 42 75.pdf PDF
AMENDMENT 0001 P1395.pdf PDF
1603164spc01of01.pdf PDF
Attachment E - Past Performance Questionnaire.docx DOCX document
Attachment F - Small Business Subcontracting Plan.docx DOCX document
1603164dwg01of03.pdf PDF
ATTACHMENT G P1395 PRICE PROPOSAL FORM.pdf PDF
1603164dwg03of03.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
Attachment D - Small Business Participation and Commitment Strategy.docx DOCX document
1603164dwg02of03.pdf PDF
P1395 RFP for N40085-19-R-9148.pdf PDF
Attachment A - Pre-Proposal Inquiries Form.xlsx XLSX spreadsheet
Attachment C - Small Business Subcontracting Record.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF REFREFREF

J

J

J

J

J

J

J

J

J

J

J

J

ACS

J

J

J

J

J

J

J

J

J

J

J J

J

J

J

J

J

J

J

J J J

J J

OPEN OFFICE

SHARED OFFICE

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

OFFICE 8

OFFICE 9

OFFICE 11

OFFICE 10

CONFERENCE ROOM

JTAC CONTROL ROOM

JTAC

CORRIDOR

MENS RESTROOM

ENTRY VESTIBULE

COVERED AREA

SECURITY

WOMENS RESTROOM

ELECTRICAL

BLUE OPS AREA

MECHANICAL SPACE

COMM

EWC

SECURITY BUNK

GFI

GFI

GFI

GFI

A 1/

E P

EP401

B1

TP

RP1-3

RP1-4

RP1-5

RP1-6

RP1-7

RP1-8

RP1-9

RP1-10

RP1-16 RP1-17

RP1-18

RP6-4

RP6-3

RP6-2

RP6-1

RP3-35

RP3-30

RP3-33

RP3-31

RP1-21 RP1-22

MP2-24

MP2-22

GFI

GFI

WP

WP

WP

RP3-32

1 1

RP6-21,23 RP6-22,24

EP402

C2

PRINTER

BREAKROOM

RP1-25

RP1-27

RP2-29

RP2-31

RP2-33

RP2-35

A

B

C

D

E

F

G

21 3 4 5 6 7 8 9

EP401

A3

RP1-20

A 1/

E P

RP1-15

CLOSET

RP6-17 RP6-18 RP6-19 RP6-20

RP6-13 RP6-14 RP6-15 RP6-16

RP6-27

AR

AR

AR AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR AR

AR

AR

AR

AR

AR

AR

AR

AR

AR AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

RP6-13 RP6-14 RP6-15 RP6-16

RP6-17 RP6-18 RP6-19 RP6-20

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR AR

AR AR

RP1-23

RP1-1

RP1-2

RP2-21,23

RP2-25,27

RP2-17,19

RP2-18,20

RP2-13,15

RP2-14,16

RP2-9,11

RP2-5,7

RP2-1,3

RP2-2,4

RP2-6,8

RP2-10,12

AR

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:4

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

EP101

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IR

S T

F

LO

O R

P

LA

N

P O

W E

R

A R

E A

A

EC

12794402

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

POWER KEYNOTES

KEY PLAN

8'4' 16'0 1/8" = 1'-0" A1

FIRST FLOOR PLAN - POWER - AREA A

A B

PLAN

NORTH

1. REFER TO PANEL SCHEDULES FOR CONDUIT AND WIRE SIZES.

2. REFER TO AUXILIARY SYSTEMS PLAN, EY101, FOR ADDITIONAL ACCESS

CONTROL SYSTEM DETAILS.

3. RECEPTACLES WITH SUBSCRIPT "AR" MUST HAVE A "CONTROLLED" MARKING

THAT COMPLY WITH NEC ARTICLE 406.3(E) "CONTROLLED RECEPTACLE

MARKING".

4. TYPICAL - AUTOMATIC RECEPTACLE CONTROL REPLAY MODULE TO BE

CONNECTED TO THE NEAREST OCCUPANCY SENSOR WITHIN THE

ROOM/AREA IT RESIDES. WHEN THE ROOM/AREA IS VACANT, OCCUPANCY

SENSOR WILL BE RESPONSIBLE FOR AUTOMATICALLY TURNING OFF THE

RECEPTACLES WITH SUBSCRIPT "AR".

5. FIELD ADJUST CONVENIENCE RECEPTACLES SHOWN SO THAT AT LEAST ONE

RECEPTACLE IS NO MORE THAN 2-3 FT FROM THE DEFIBRILLATOR WITHIN ITS

RESPECTIVE ROOM.

6. PROVIDE 6" LINEAR SEPARATION BETWEEN POWER AND DATA NETWORK

CABLES.

7. FOR FURNITURE CONNECTIONS, NO MORE THAN THREE CUBICLES ARE TO BE

CONNECTED TO A CIRCUIT.

1 30A DISCONNECT SWITCH FOR OVERHEAD DOOR.

2 RECEPTACLE FOR TIME ZONE CLOCK. COORDINATE MOUNTING HEIGHT WITH

CLOCK LOCATION SUCH THAT RECEPTACLE IS HIDDEN BEHIND CLOCK.

3 FOR THE OPEN OFFICE AREA - CONNECT EACH OF THE FOLLOWING CIRCUITS

TO AN AUTOMATIC RECEPTACLE CONTROL REPLAY MODULE THAT MEETS

THE AUTOMATIC RECEPTACLE REQUIREMENT OF ASHRAE 90.1:

* RP2-3, RP2-4, RP2-7, RP2-8, RP2-11, RP2-12, RP2-15, RP2-16, RP2-19,

RP2-20, RP2-23 AND RP2-27

EACH RECEPTACLE CONTROLLER MUST BE CAPABLE OF COMMUNICATING

WITH THE OCCUPANCY SENSOR, WITHIN ITS RESPECTIVE AREA, THRU

WIRELESS TECHNOLOGY.

4 FOR OPEN OFFICE AREA - CONTRACTOR TO WIRE 50% OF THE RECEPTACLES

IN EACH MODULAR FURNITURE SYSTEM TO AN AUTOMATIC CONTROL

RECEPTACLES CIRCUIT TO ENSURE AREA IS IN COMPLIANCE WITH THE

AUTOMATIC RECEPTACLE REQUIREMENT OF ASHRAE 90.1.

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

R E

F

R E

F R

E F

R E

F

FACP

J

J

J

J

J J

J J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

JJ

J

J

CORRIDOR

FIRE ALARM ROOM

TRASH/MANT.

BREAKROOM

OFFICE 6

TEAM ROOM

PURPLE OPS AREA

GREEN OPS AREA

CONFERENCE ROOM

OFFICE 5

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 1

CO OFFICE

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

CO OFFICE

207OFFICE 8

TEAM ROOM

BREAKROOM

CONFERENCE ROOM

CONFERENCE ROOM

PRINTER

RECEPTION

CORRIDOR

A 1/

E P

RP3-1

RP3-2

RP3-3

RP3-4

RP3-5

RP3-6

RP3-10

RP3-12RP3-13

RP3-16

RP3-17

RP3-15

RP4-1

RP4-2

RP4-3

RP4-4

RP4-5

RP4-7

RP4-8

RP4-9

RP4-11

RP4-14

RP4-15

RP4-16

RP4-17

RP4-18

RP4-19 RP4-20

RP4-21

RP4-22

RP4-23

RP4-24

RP4-29

RP4-30

RP4-31

RP4-32

RP3-11

ANT

WP WP

WP

RP5-20,22

1 1

RP5-19,21

ANT-1 ANT-2

WPWP

ANT-4

ANT-3

WP

WP

ANT-6

WP WP

EP402

A1

EP402

A3

A

B

C

D

E

F

8 9 10 11 12 13 14

RP4-34

RP3-8

RP3-14

RP4-10

RP4-12

A 1/

E P

RP3-9

GP-2

RP4-13

RP3-22

RP3-26 RP3-27

RP3-23 RP3-24

RP3-28 RP3-29

RP3-25

RP5-13 RP5-14 RP5-15 RP5-16 RP5-17 RP5-18

RP5-7 RP5-8 RP5-9 RP5-10 RP5-11 RP5-12

RP5-1 RP5-2 RP5-3 RP5-4 RP5-5 RP5-6

2 2

ANT-5

GFI

RP4-25

AR

AR

AR

AR

AR

AR

AR

AR

AR AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR AR

AR

AR AR

AR

AR

AR

AR

WP

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR AR

AR

AR

AR

AR

AR AR

AR AR

AR AR

AR AR

AR AR

AR

AR AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

AR

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:5

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

EP102

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IR

S T

F

LO

O R

P

LA

N

P O

W E

R

A R

E A

B

EC

12794403

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

POWER KEYNOTES

KEY PLAN

8'4' 16'0 1/8" = 1'-0" A1

FIRST FLOOR PLAN - POWER - AREA B

A B

PLAN

NORTH

1 30A DISCONNECT SWITCH FOR OVERHEAD DOOR.

2 RECEPTACLE FOR TIME ZONE CLOCK. COORDINATE MOUNTING HEIGHT WITH

CLOCK LOCATION SUCH THAT RECEPTACLE IS HIDDEN BEHIND CLOCK.

1. REFER TO PANEL SCHEDULES FOR CONDUIT AND WIRE SIZES.

2. REFER TO AUXILIARY SYSTEMS PLAN, EY101, FOR ADDITIONAL ACCESS

CONTROL SYSTEM DETAILS.

3. RECEPTACLES WITH SUBSCRIPT "AR" MUST HAVE A "CONTROLLED" MARKING

THAT COMPLY WITH NEC ARTICLE 406.3(E) "CONTROLLED RECEPTACLE

MARKING".

4. TYPICAL - AUTOMATIC RECEPTACLE CONTROL REPLAY MODULE TO BE

CONNECTED TO THE NEAREST OCCUPANCY SENSOR WITHIN THE

ROOM/AREA IT RESIDES. WHEN THE ROOM/AREA IS VACANT, OCCUPANCY

SENSOR WILL BE RESPONSIBLE FOR AUTOMATICALLY TURNING OFF THE

RECEPTACLES WITH SUBSCRIPT "AR".

5 FIELD ADJUST CONVENIENCE RECEPTACLES SHOWN SO THAT AT LEAST ONE

RECEPTACLE IS NO MORE THAN 2-3 FT FROM THE DEFIBRILLATOR WITHIN ITS

RESPECTIVE ROOM.

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

SAPL

ING

QL-C

QL-C

QL-C

FO P

aint bo/c ut

EOI

EOIEOI

QL-C

QL-

C

EVERE

TT CR

EEK R

D ASPHALT SURFACE

ASP

H

ALT

S U R

FAC

E

7'

CH

AIN

LINK

W/B

ARB

ED

WIR

E F

ENC

E

7' CHAINLINK W/BARBE WIRE FENCE

C O N C W

ALK

META

L SIG

N

ASPH

ALT P

ATH

TMH

RIM=

37.5

TCAB #FOC69-02 48G10F

TMH

RIM=36.52

L/P

L/P

P/P

P/P P/P P/P

L/P

EMH

WV

TON=

37.91

WOODS

WOODS

ROAD (GRAVEL)

EG

T

E

O U

TS

ID

E S W

EP

T P A

TH

IN

S

ID

E S W E P T P A

TH

.1 ft

.0 ft

7.

ft

.0 f t

.0 f t

8.

ft

J

J

J

J

J

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

U P

U P

U P

U P

U P

U C

U C

U C

U C

U C

U C

U C

UC

UC

UC

U C

U C

U C

U C

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

U P

U P

U P

U P

U P

U P

U P

UC

UC

UC

UC UCUC UC UC UC

U P

U P

U P

U P

U P

U P

U P

U P

UP UP

75KW GENERATOR

500KVA TRANSFORMER

AND UTILITY METER

S1

S1

S1

S1

S1

2-5" PVC CONDUIT

2-5" CONDUIT

HANDHOLE

(TYPICAL)

PERIMETER FENCE

FENCE

LOADING, STAGING,

SATELLITE ETC. AREA

FENCE

PERIMETER FENCE

PERIMETER FENCE

ACCESS RO

AD

ACC-1

SEE DETAIL A2 & A4 /EP503

ANT

TO EXISTING

MANHOLE MHRR 114-7

LP1-22

LP1-18

SETBACK

(TYPICAL)

EXISTING

UTILITY POLE

S1 S1

S1

S1

S1

2-5" CONDUIT

TP-23

TP-37

RP5-23

TURNSTILE

SLIDING GATE

GP-10

GP-8

16 17

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:5

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ES101

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

S

IT

E P

LA

N

E

LE

C

TR

IC

A L

EC

12794395

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

ELECTRICAL KEYNOTES

1" = 50'-0" A1

SITE PLAN - ELECTRICAL

50 1000 50 1000

1. FIELD VERIFY NEMA 4X NOTE THAT EACH ENCLOSURE REQUIRE AN 'END USER'S EQUIPMENT CABLING PENETRATION TO BE COORDINATED BETWEEN USMC AND THE ELECTRICAL CONTRACTOR BEFORE FINAL INSTALLATION. COORDINATE ENCLOSURE LOCATIONS WITH OWNER

PRIOR TO INSTALLATION.

2. NEMA 4X TELECOMMUNICATION ENCLOSURES TO BE MOUNTED AT 48" AFG.

3. COORDINATE ALL UNDERGROUND STRUCTURES AND UTILITIES PRIOR TO BEGINNING WORK.

4. COMMUNICATION CONDUIT BENDS SHALL BE SWEEPS WITH A MINIMUM RADIUS OF TEN TIMES THE INTERNAL DIAMETER.

5. NO SECTION OF COMMUNICATION CONDUIT SHALL CONTAIN NO MORE THAN TWO 90 DEGREE BENDS OR EQUIVALENT BETWEEN PULL POINTS.

6. INSTALL MAINTENANCE HOLES WHERE CONDUIT SECTION LENGTH EXCEEDS 400FT.

7. DUCTS TO BE SEALED TO RESIST LIQUID AND GAS INFILTRATION AT BOTH ENDS AND CLEARLY MARKED ON OUTSIDE END.

8. UNDERGROUND CONDUITS TO BE INSTALLED SO THAT A SLOPE EXIST AT ALL POINTS OF THE RUN TO ALLOW DRAINAGE AND PREVENT

ACCUMULATION OF WATER. SLOPE SLEEVES DOWNWARD 0.125IN/FT AWAY FROM BUILDING.

9. UPON ENTERING THE BUILDING TERMINATE ALL OSP COPPER CABLES ON THE PROTECTED ENTRANCE TERMINAL (PET).

10. ALL COPPER AND FIBER TELECOMMUNICATION CABLES SHOWN ON THIS SHEET ARE TO BE OSP RATED.

11. PROVIDE A MINIMUM COMMUNICATION HANDHOLE SIZE OF 4'x4'x4', AND COMMUNICATION MAINTENANCE HOLE SIZE OF 6'x7'x8'. PROVIDE

HANDHOLES WITH ROUND LIDS AND OPEN BOTTOM.

12. UNDERGROUND PORTION SHALL BE ENCASED IN MINIMUM OF 3" OF CONCRETE EXTENDING FROM THE BUILDING ENTRANCE TO OSP

DEMARCATION POINT.

1 ROUTE FOUR 4" CONDUITS BELOW GRADE FROM COMM ROOM TO EXISTING UTILITY MANHOLE AT EVERETTE CREEK RD. FOR CONNECTION DEMARK. INSTALL TWO 3-CELL FABRIC INNER DUCTS IN EACH CONDUIT THAT CONTAIN FIBER CABLES. INSTALL A PULL WIRE INSIDE EACH OF THE INNERDUCTS. REFER TO COMMUNICATIONS RISER DIAGRAM FOR ADDITIONAL INFORMATION. ROUTE ONE SET OF 48 STRANDS OF SINGLEMODE FIBER OPTIC CABLE IN ONE CONDUIT, AND 100 PAIR OF COPPER CABLES IN ANOTHER CONDUIT.

2 ROUTE ONE SET OF 36 STRANDS OF SINGLEMODE FIBER OPTIC CABLE, AND 50 PAIR OF COPPER CABLES BELOW GRADE IN 4" CONDUIT FROM COMM ROOM 107 TO NETWORK SWITCH AT ANTENNA PAD. INSTALL TWO 3-CELL FABRIC INNERDUCTS WITHIN THE CONDUIT. INSTALL A PULL WIRE INSIDE EACH OF THE INNERDUCTS. SEE TELECOMMUNICATION RISER DIAGRAM FOR ADDITIONAL INFORMATION.

3 EXCAVATION NEAR BUILDING TO BE PERFORMED WITH HAND TOOLS OR NON-DESTRUCTIVE TOOLS UNTIL THE FACILITY IS EXPOSED, OR

MAXIMUM DEPTH OF THE INTENDED EXCAVATION IS REACHED.

4 PROVIDE NEMA 4X CABINET FOR 12 PORT NETWORK SWITCH. CABINET TO BE SUPPLIED WITH AN INTEGRAL HANDLE, FOR PHYSICAL LOCKING CAPABILITY, AND MUST BE KEYED FOR TYPICAL CAMP LEJEUNE USMC APPLICATION COPPER CABLES TO TERMINATE ON KRONE BLOCK AND LIGHTNING PROTECTOR TO PROVIDE DIAL TONE. COPPER CABLES TO BE TERMINATED ON RJ45 PATCH PANEL WITHIN NEMA 4X CABINET.

FIBER CABLE TO TERMINATE ON SC TYPE CONNECTORS IN A RACK MOUNTABLE (PCH FDP). NETWORK SWITCH TO BE GOVERNMENT FURNISHED GOVERNMENT INSTALL. REFER TO "EQUIPMENT MOUNTING STRUCTURE" DETAIL ON SHEET EP502.

5 ROUTE EIGHT CATEGORY 6 (CAT6) OUTDOOR RATED WATER BLOCK CABLES IN 1-1/2" CONDUIT BELOW GRADE TO NEMA 4X ENCLOSURE

NOTED IN KEYNOTE 6.

6 PROVIDE NEMA 4X CABINET FOR TERMINATION OF CAT6 CABLES. CABINET TO BE SUPPLIED WITH AN INTEGRAL HANDLE, FOR PHYSICAL LOCKING CAPABILITY, AND MUST BE KEYED FOR TYPICAL CAMP LEJEUNE USMC APPLICATION CABLES TO BE TERMINATED PER BASE TELECOMMUNICATIONS STANDARDS. CABINETS MUST HAVE WEATHERPROOF "WHILE-IN-USE" PATHWAYS FOR USER CABLING SO CABLING CAN FEED GOVERNMENT EQUIPMENT WITH CABINET CLOSED. REFER TO "EQUIPMENT MOUNTING STRUCTURE" DETAIL ON SHEET EP502.

7 LOCATE NOTED TELECOMMUNICATION HANDHOLE A MINIMUM OF 6' FROM BUILDING ENTRANCE.

8 SITE LUMINAIRES NOT APART OF THE BASE BID PACKAGE. ONLY CIRCUIT, FEEDERS, AND CONDUIT TO BE STUBBED UP UNDER BASE BID

PACKAGE TO EDGE OF ACCESS ROADWAY.

9 15KV, 200A, 2-WAY ALUMINUM SECTIONALIZING CABINET.

10 ROUTE TWO DEDICATED 20A, 1-POLE CIRCUITS BELOW GRADE TO EACH CABINET FROM PANEL 'ANT'. ROUTE CONDUIT PARALLEL TO 1-1/2" COMM CONDUIT REFERENCE IN KEYNOTE #6. REFER TO PANELBOARD SCHEDULE 'ANT' FOR CIRCUIT NUMBER, WIRE, AND CONDUIT

INFORMATION.

11 FOR GATE OPERATOR - PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMM) ADJACENT TO GATE OPERATOR LOCATION. ROUTE BELOW GRADE TO GATE OPERATOR SYSTEM AND ELECTRICAL PANEL LOCATED IN ELECTRICAL ROOM 108. COORDINATE ADDITIONAL WIRING

REQUIREMENTS WITH GATE OPERATOR SUPPLIER.

12 FOR CARD READER/INTERCOM NEAR VEHICLE ACCESS GATE - PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMM) UNDER STANCHION LOCATION. ROUTE BELOW GRADE TO ACCESS CONTROL SYSTEM, AND ELECTRICAL PANEL, LOCATED IN COMM ROOM 107. COORDINATE

ADDITIONAL WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER.

13 FOR CARD READER/INTERCOM NEAR MAIN ACCESS GATE - PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMM) NEAR MAIN GATE LOCATION. ROUTE BELOW GRADE TO ACCESS CONTROL SYSTEM, AND ELECTRICAL PANEL, LOCATED IN COMM ROOM 107. COORDINATE

ADDITIONAL WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER.

14 PROVIDE WEATHERPROOF "WHILE IN USE" GFI NEMA 120V, 20A DEDICATED RECEPTACLES MOUNTED ON BOTTOM OF STEEL STRUCTURE AS IDENTIFIED IN KEYNOTE 10. REFER TO "EQUIPMENT MOUNTING STRUCTURE" DETAIL ON SHEET EP502.

15 FEEDER AND CONDUIT TO BE ROUTED TO DISTRIBUTION PANELBOARD 'DP', IN ELECTRICAL ROOM. REFER TO POWER RISER DIAGRAM FOR

ADDITIONAL INFORMATION.

16 FOR CARD READER/INTERCOM - PROVIDE 2" CONDUIT STUB-UP UNDER STANCHION LOCATION. ROUTE BELOW GRADE TO INTERCOM AND ACCESS CONTROL SYSTEM LOCATED IN COMM ROOM 107. COORDINATE ADDITIONAL WIRING REQUIREMENTS WITH STANCHION SUPPLIER.

17 FOR GATE OPERATOR, PROVIDE TWO 1" CONDUIT STUB UPS (1-POWER/1-COMMS) ADJACENT TO GATE OPERATOR LOCATION. ROUTE BELOW GRADE TO OPERATOR SYSTEM, AND TO CIRCUIT SHOWN, LOCATED IN ELECTRICAL ROOM 108. COORDINATE ADDITIONAL WIRING

REQUIREMENTS WITH GATE OPERATOR SUPPLIER.

18 FOR TURNSTILE, PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMMS) ADJACENT TO TURNSTILE LOCATION. ROUTE BELOW GRADE TO GATE OPERATOR SYSTEM, AND CIRCUIT SHOWN, LOCATED IN ELECTRICAL ROOM 108. COORDINATE ADDITIONAL WIRING REQUIREMENTS

WITH TURNSTILE SUPPLIER. N

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

COMMUNICATIONS LEGEND ABBREVIATIONSGENERAL NOTES

TV

A AMPERE

AC ABOVE COUNTER, 42" AFF UNLESS NOTED OTHERWISE

ACS ACCESS CONTROL SYSTEM

ADA AMERICANS WITH DISABILITIES ACR

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AL ALUMINUM

1/C ONE CONDUCTOR PER CONDUIT

BMS BALANCED MAGNETIC SWITCH

CB CIRCUIT BREAKER

CKT CIRCUIT

CP CONSOLIDATION POINT

CU COPPER

EF EXHAUST FAN

EMT ELECTRICAL METALLIC TUBING

EWC ELECTRIC WATER COOLER

FACP FIRE ALARM CONTROL PANEL

FM FREQUENCY MODULATION

FO FIBER OPTIC

GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED

GFI GROUND FAULT CIRCUIT INTERRUPTER

GFP GROUND FAULT PROTECTION

HACR HEATING AIR CONDITIONING REFRIGERATION

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HT HEIGHT

HZ HERTZ

IDS INTRUSION DETECTION SYSTEM

J JUNCTION BOX

KWH KILOWATT HOURS

LED LIGHT EMITTING DIODE

MCB MOLDED CASE CIRCUIT BREAKER

MH METAL HALIDE

MLO MAIN LUG ONLY

MTD MOUNTED

MUTOA MULTIUSER TELECOMMUNICATIONS OUTLET ASSEMBLY

NEC NATIONAL ELECTRICAL CODE

NF NON-FUSED

NO. NUMBER

OS OCCUPANCY SENSOR

PH PHASE

PIR PASSIVE INFRARED

PTZ PAN TILT ZOOM CAMERA

RGS RIGID GALVANIZED STEEL

SM SINGLE MODE

TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

UON UNLESS OTHERWISE NOTED

V VOLT

VA VOLTAMPERE

VTC VIDEO TELECONFERENCING

VVD VARIABLE VOLUME DAMPER

W WATTS

WP WATERPROOF

XFMR TRANSFORMER

CONFERENCE ROOM RECESSED FLOOR BOX (WITH FLUSH LIDS) CONTAINING

NON-SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET UNLESS SUBSCRIPT

INDICATES OTHERWISE. NON-SECURE DATA OUTLET SHALL BE LIMITED TO

NIPRNET DATA DEVICES.

CONFERENCE ROOM RECESSED FLOOR BOX (WITH FLUSH LIDS) CONTAINING

SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET UNLESS SUBSCRIPT

INDICATES OTHERWISE. SECURE DATA OUTLET SHALL BE LIMITED TO

SIPRNET DATA DEVICES.

NON-SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET MOUNTED 18" AFF

UNLESS SUBSCRIPT INDICATES OTHERWISE. NON-SECURE DATA OUTLET

SHALL BE LIMITED TO NIPRNET DATA DEVICES.

SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET MOUNTED 18" AFF

UNLESS SUBSCRIPT INDICATES OTHERWISE. SECURE DATA OUTLET SHALL BE

LIMITED TO SIPRNET DATA DEVICES.

NON-SECURE VOICE (POTS) OUTLET MOUNTED 46" AFF UNLESS NOTED

OTHERWISE.

NON-SECURE DATA OUTLETS WITH TWO 8P8C JACKS. OUTLETS TO BE

CENTERED ABOVE FINISHED FLOOR AT THE HEIGHT INDICATED ON THE AREA

AV FLOOR PLANS. REFER TO THE TA-100 SERIES DRAWINGS FOR THE

RESPECTIVE MOUNTING HEIGHT OF EACH OUTLET PRIOR TO ROUGH-IN.

144-PORT FIBER OPTIC DISTRIBUTION PANEL FOR TERMINATION OF

HORIZONTAL AND BACKBONE FIBER OPTIC CABLING.

HORIZONTAL CABLE MANAGEMENT UNITS (CABLE GUIDES).

CONDUIT STUB INTO ROOM.

SIPR CABLE TRAY.

NIPR CABLE TRAY.

S

S

1. JACK SHALL BE LABELED AND COLOR CODED BASED ON THE TYPE OF TRAFFIC THEY HANDLE.

REFER TO "NETWORK COLOR MATRIX" DETAILS ON THE TELECOMMUNICATIONS DETAIL PRIOR

TO INSTALLATION.

2. CONDUITS ENTERING COMM ROOMS THROUGH THE FLOOR SHALL BE INSTALLED SO THAT THEY ARE AT LEAST 1" FROM THE PLYWOOD MOUNTED ON THE WALL AND EXTEND AT LEAST 3" ABOVE

FINISHED FLOOR AND SHALL HAVE A PROTECTIVE BUSHING ON THE END OF THE CONDUIT TO

PROTECT THE CABLING.

3. CONDUITS ENTERING/EXITING COMM ROOMS THROUGH THE WALL OR CEILING SHALL BE

INSTALLED SO THAT THEY ARE 1"-3" FROM THE WALL/CEILING AND SHALL HAVE A PROTECTIVE

BUSHING ON THE END OF THE CONDUIT TO PROTECT THE CABLING.

4. WHERE APPLICABLE, BUNDLING AND SECURING OF CABLES SHALL BE ACCOMPLISHED THRU

USE OF VELCRO TAPE.

5. CLASSIFIED (SIPRNET) AND UNCLASSIFIED (NIPRNET) NETWORKS CANNOT BE IN THE SAME

JACKET REGARDLESS OF CABLE CONSTRUCTION.

6. ALL CABLES SHALL BE PLENUM RATED.

7. TEN FOOT CAT6 DEVICE CABLES SHALL BE PROVIDED TO EQUAL 1.1 TIMES THE NUMBER OF

LOCATION WHERE CAT6 JACKS ARE INSTALLED. EXAMPLE: IF 100 JACK LOCATIONS ARE

INSTALLED THEN PROVIDE 110 DEVICES CABLES (1.1x100).

8. SPARE JACKS SHALL BE PROVIDED TO EQUAL 0.1 TIMES THE TOTAL NUMBER OF SHIELDED CAT6A OR FIBER OPTIC OUTLET JACKS INSTALLED. EXAMPLE: IF 100 JACK LOCATIONS ARE INSTALLED THEN PROVIDE 10 SPARE JACKS (0.1x100).

9. PROVIDE DEVICE CABLES AND SPARE JACKS FOR EACH DIFFERENT SYSTEM.

10. FIBER-OPTIC CABLES SHALL HAVE A MINIMUM OF TEN FEET OF SLACK ON EACH END.

11. OSP FIBER-OPTIC CABLES SHALL HAVE A MINIMIUM OF TEN FEET OF SLACK ON EACH END.

12. TERMINATE ALL BACKBONE FIBER-OPTIC STRANDS THROUGH USE OF SC-TYPE NO EPOXY/NO

POLISH MECHANICAL SPLICED FIBER-OPTIC CONNECTORS WITH CERAMIC TIP.

13. THE POTS SYSTEM HEADEND AND HANDSETS WILL BE GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED.

14. ALL NETWORK ELECTRONICS INCLUDING, BUT NOT LIMITED TO CORE SWITCHES, EDGE

SWITCHES, SERVERS, ETC., SHALL BE GOVERNMENT FURNISHED AND GOVERNMENT

INSTALLED.

15. COMMUNICATIONS CONTRACTOR SHALL TERMINATE ALL BACKBONE AND HORIZONTAL CABLING

UNLESS SPECIFICALLY INSTRUCTED OTHERWISE. PROVIDE ALL NECESSARY PATCH PANELS,

PUNCH DOWN BLOCKS, MATERIALS, ETC. FOR A COMPLETE SYSTEM.

16. PATCH CORDS PROVIDED SHALL BE FACTORY MADE; COPPER OR FIBER MATERIAL SHALL BE

RATED TO MATCH FACILITY NETWORK SPECIFICATIONS.

17. ALL PATCH PANELS SHALL MATCH THE CATEGORY CABLING TERMINATED ON THEM AND HAVE

SUFFICIENT PATCH CORDS PROVIDED TO FULLY UTILIZE THE PATCH PANELS.

18. COPPER PATCH CORD SHALL BE: FOUR PAIR, 100-OHM TWISTED PAIR CABLE WITH 24 GAUGE

STRANDED COPPER CONDUCTORS AND MUST MEET THE SPECIFICATIONS TO SUPPORT GIGABIT

ETHERNET AND AT LEAST 500MHZ BANDWIDTH.

19. PROVIDE PATCH CORDS FOR EACH DIFFERENT SYSTEM.

20. FLEXIBLE METAL RACEWAY SYSTEMS ARE NOT PERMITTED FOR CABLE DISTRIBUTION.

21. DEVICE COVER AND FINISH TO BE COORDINATED WITH ARCHITECT.

22. PROVIDE KRONE PATCH CORDS FOR VOICE/POTS.

DC

MS MS

DP

CR

KP

PP

DA

CCTV

KPM

BACKBOX FOR DOOR CONTACT, BMS. LOCATE 2" ABOVE AND 2" TO THE SIDE

OF THE DOOR.

BACKBOX FOR DOOR POSITION SWITCH.

BACKBOX FOR LOCAL DOOR ANNUNCIATOR.

BACKBOX FOR CARD READER, MOUNT 4'-0" AFF UNLESS NOTED OTHERWISE.

BACKBOX FOR KEYPAD. MOUNT 4'-0" AFF UNLESS NOTED OTHERWISE.

BACKBOX FOR ACS SECURITY PIN PAD. MOUNT 4'-0" AFF UNLESS NOTED

OTHERWISE.

BACKBOX FOR PREMISE (IDS/ACS) CONTROL UNIT. KEYPAD OF PREMISE

CONTROL UNIT SHALL BE USED TO MONITOR AND ARM/DISARM ALL MOTION AND

GLASS BREAK SENSING DEVICES WITHIN THE FACILITY. MOUNT 4'-0" AFF

UNLESS NOTED OTHERWISE.

BACKBOX FOR PASSIVE INFRARED OR DUAL TECHNOLOGY MOTION DETECTOR.

SUBSCRIPT INDICATES THAT SENSOR DEVICE CAN BE ARM/DISARM BY KEYPAD

WITH SIMILAR SUBSCRIPT.

S BACKBOX FOR CEILING MOUNTED AV SPEAKER. COORDINATE ROUGH-IN

LOCATIONS WITH AV INSTALLER PRIOR TO ROUGH-IN.

CC BACKBOX FOR WALL CCTV DOME CAMERA.

CCTV SYSTEM EQUIPMENT WORKSTATION WITH - WALL MOUNTED MONITOR.

PROVIDE MOUNTING BRACKETS AND OTHER ENHANCEMENTS REQUIRED TO

SECURELY MOUNT THE EQUIPMENT.

FB OPEN OFFICE NON-SECURE FLUSH-MOUNTED DATA FLOOR BOX FOR CABLE

CONNECTION TO FURNITURE SYSTEM. INSTALLED IN ACCESS FLOOR SPACE.

PROVIDE EACH FLOOR BOX WITH TWELVE CAT6 DATA PORTS UNLESS

SUBSCRIPT INDICATES OTHERWISE. PROVIDE TWO DATA PORTS AT EACH

DESK.

FB OPEN OFFICE SECURE FLUSH-MOUNTED DATA FLOOR BOX FOR CABLE

CONNECTION TO FURNITURE SYSTEM. INSTALLED IN ACCESS FLOOR SPACE.

PROVIDE EACH FLOOR BOX WITH TWELVE CAT6 DATA PORTS UNLESS

SUBSCRIPT INDICATES OTHERWISE. PROVIDE TWO DATA PORTS AT EACH

DESK.

S

KVM FLUSH MOUNTED FLOORBOX WITH KVM AND AUX CONNECTIONS. COORDINATE

QUANTITY OF CONNECTIONS, AND ROUGH-IN LOCATION, WITH AV INSTALLER

PRIOR TO ROUGH-IN. PROVIDE 4-GANG BACKBOX UNLESS SUBSCRIPT INDICATES

OTHERWISE.

RECESSED FLOOR BOX (WITH FLUSH LIDS) CONTAINING 4-GANG BACKBOX

FOR A/V DEVICE CONNECTION. SEE A/V DRAWINGS FOR ADDITIONAL

INFORMATION.

A

WIP WIRELESS INTRUSION PREVENTION SYSTEM SENSOR WITH PoE.

CDS WALL MOUNTED CELLPHONE DETECTION SYSTEM SENSOR WITH PoE AND

INTEGRAL ANTENNA.

18" AFF WALL MOUNTED BACKBOX FOR A/V DEVICE CONNECTION. PROVIDE

2-GANG BACKBOX UNLESS SUBSCRIPT INDICATES OTHERWISE. COORDINATE

QUANTITY OF CONNECTIONS AND ROUGH-IN LOCATIONS WITH AV INSTALLER

PRIOR TO ROUGH-IN.

A

GS BACKBOX FOR DUAL (ACOUSTIC AND SHOCKWAVE) TECHNOLOGY GLASS

BREAK SENSOR. PROVIDE SENSORS RATED FOR THE TYPE OF GLASS USED

THROUGHOUT THE FACILITY. SUBSCRIPT INDICATES THAT SENSOR DEVICE

CAN BE ARM/DISARM KEYPAD WITH LIKEWISE SUBSCRIPT.

COMMUNICATIONS LEGEND - (CONTINUED)

C CEILING MOUNTED NON-SECURE DATA OUTLETS WITH FOUR 8P8C JACKS.

SECURE DATA WITH SIX LC FIBER OPTIC JACKS PER OUTLET MOUNTED AT 18"

AFF.

FO

J

SYSTEM FURNITURE CONNECTION. PROVIDE EACH SYSTEM FURNITURE

CONNECTION WITH TWELVE CAT6 DATA UNLESS NUMERICAL SUBSCRIPT

INDICATES OTHERWISE. PROVIDE TWO DATA PORTS AT EACH DESK. SUBSCRIPT

"S" INDICATES SECURE CABLES.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:5

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET001

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

TE

LE

C O

M M

U N

IC

A

TI

O

N S

L E

G E

N D

, A B

B R

E V

IA

TI

O N

S A

N D

G E

N E

R A

L N

O

TE

S

JAZ

12794419

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

REF REFREFREF

FB FB

FB FBFB FB

FB FBFB FB

FB FBFB FB

KVM

KVM

FB FB

J J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

ET401

C2

S

S

TV

S

TV

TV

TV

TV

TV

TV

S

S A

S

S

S

S

S

A

S

S

S

S

S

S

S

S

S

S

TV

S

S

TV

S

S

S

S

S

S

S

S

WP

48"

S

S S

S

S

S

S

S

S

A 1/

E T

TV TV

TV

TV

WP

TV

TV

TV

TV

8 8 8 8S S

8 8 8 8

8 8 8 8

S S8 8 8 8S S

TV

UPS AND BATTERY

CABINET

48"

A

A

A

A

A

S

S

S

S

S

A

S

S

A

S

S

A

A

A

A

S A

S

S

A

B

C

D

E

F

G

21 3 4 5 6 7 8 9

A A

A

FOR VIDEO

DISPLAY WALL

FOR PROJECTOR

FOR PROJECTOR

SHARED

OFFICE

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

OFFICE 8

OFFICE 9

OPEN

OFFICE

OFFICE 11

OFFICE 10

JTAC

CONTROL

ROOM

CONFERENCE

ROOM

PRINTER

BLUE OPS

AREA

JTAC

COMM

ELECTRICAL

MECHANICAL

SPACE

CORRIDOR

COVERED

AREA

SECURITY

103 SECURITY

BUNK

MENS

RESTROOM

ENTRY

VESTIBULE

WOMENS

RESTROOM

C

C

S

S S

FO

S

CLOSET

A 1/

E T

OUTSIDE

DOOR

48"

S

TV

TV

TV

TV

TV

TV

S

S

S

S

S

S

S

S

S

S

S

S

A S

S

S

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:0

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET101

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IR

S T

F

LO

O R

P

LA

N

T E

LE

C

O M

M U

N

IC

A

TI

O N

S

A R

E A

A

JAZ

12794420

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

TELECOMMUNICATIONS KEYNOTES

KEY PLAN

8'4' 16'0 1/8" = 1'-0" A1

FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA A

A B

PLAN

NORTH

1. PROVIDE SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND NIPRNET

DEVICE OUTSIDE EDGE OF 5"x5" BOX.

2. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND

NIPRNET CABLE PATHWAYS AND TERMINATIONS.

3. IN INDIVIDUAL OFFICES, MOUNT TV OUTLETS AT 66"AFF. IN OPEN OFFICES

MOUNT TV OUTLETS AT 72"AFF. LOCATE TV OUTLET ADJACENT TO THEIR

RESPECTIVE POWER RECEPTACLE.

4. FLOOR BOX TO BE LIMITED TO SERVING A MAXIMUM OF 6 WORK AREAS (ALL

PART OF ONE FURNITURE CLUSTER). PROVIDE EACH DESK AREA WITH TWO

NIPR AND TWO SIPR DATA OUTLETS.

5. MOUNT DATA OUTLETS ADJACENT TO POWER OUTLETS, WITH A SEPARATION

DISTANCE OF 6" BETWEEN THE EDGE OF DATA AND POWER FACEPLATES.

6. IN CONFERENCE ROOMS, FLOOR BOXES TO BE ALIGNED NEAR EDGE OF

TABLES AND WITH TABLE LEGS FOR CABLE MANAGEMENT OF POWER, DATA,

AND A/V DEVICES.

7. PROVIDE 6" LINEAR SEPARATION BETWEEN POWER AND DATA NETWORK

CABLES.

8. PROVIDE 2 PORTS PER SYSTEM FURNITURE AND FLOOR BOXES IN

MULTIPLES OF 4. TERMINATE TWO CABLES IN DESK FURNITURE PER

CLASSIFIED NETWORK.

9. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST

REQUIREMENTS.

1 CEILING MOUNTED OUTLET. MOUNT 3-6 INCHES ABOVE THE CEILING.

2 SURFACE MOUNT ALL TELECOMMUNICATIONS DEVICES WITHIN THIS ROOM.

3 CAT6 CABLE ROUTING SHOWN TO AND FROM FLOOR BOXES WITHIN THIS ROOM

ARE DIAGRAMMATIC. COORDINATE ACTUALLY ROUTING OF CAT6 CABLING

WITHIN FLOOR CABLE PATHWAY SYSTEM IN THE FIELD. REFER TO "WALL TO

ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

R E

F

R E

F R

E F

R E

F

FB FB FB

FB

FB FB FB FB

FB FB FB FB

FB FB FB FB FB

FB

FB

FB

FB

FB

FB FB FB FB FB FB

FB FB FB FB FB

FB FB FB FB FB FB

FB

FB

FB

KVM

KVM

KVM

KVM

FB FB FB FB

FB

FB

FB

FB

TV

TV

S S

A

FO

WP

S

S

S

ASTV

TV

S

S

S

S

TV

S

S

TV S

S

STV

S S

S S

SS

SS

48"

S S

S

S

TV

S S S S

SS

S

S

TV

SS

S

SS

TV

S

S

S

TV

S

A

S

TV S

S

S

TV

S

S

S

TV

S

S

S

TV

S

S

S

TV

S

S

S

TV

S

S

S

WP

S

S

S

S

S S S S S S

S

S

A 1/

E T

TV

TV

TV

TV

TV

S

TV TV

TV TV

TV

TV

TV

TV

TV TV

TV TV

TVTV

S S S

8 S

S8 S S8 8 8 S

TV

S8 S S8 8 S8 S8

S8

8 8 8 8 8 8

S8 S S8 8 8 S 8 S

8 8

S8

S8

A S

C

C

A S

C

C

S

A

A

S

S

A

S

A

A

A

A

SA

AAA A A A

A A

A

A

A

A

A

A

S

A

S

TV

TV

1 1

1 1

A

B

C

D

E

F

8 9 10 11 12 13 14

A

FOR PROJECTOR

FOR PROJECTOR

FOR PROJECTOR

FOR PROJECTOR

AA

A

A

A

A

PURPLE

OPS AREA

OFFICE 6

TEAM

ROOM

FIRE

ALARM

ROOM

TRASH/MANT.

BREAKROOM

CORRIDOR

CONFERENCE

ROOM

OFFICE 5

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 1

CO OFFICE

GREEN

OPS AREA

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

CO OFFICE

PRINTER

OFFICE 8

RECEPTION

TEAM

ROOM

CONFERENCE

ROOM

CONFERENCE

ROOM

BREAKROOM

S

S

A

TV

S

A

48"

S

S

S

FO

A 1/

E T

A

OUTSIDE

DOOR

OUTSIDE

DOOR

S

S S

TV

S

FOR VIDEO

DISPLAY WALL

FOR VIDEO

DISPLAY WALL

48"

3 4

8 8 8

S

S

S S

8 S

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:0

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET102

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IR

S T

F

LO

O R

P

LA

N

T E

LE

C

O M

M U

N

IC

A

TI

O N

S

A R

E A

B

JAZ

12794421

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

TELECOMMUNICATIONS KEYNOTES

KEY PLAN

1/8" = 1'-0" A1

FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA B

8'4' 16'0

A B

PLAN

NORTH

1. PROVIDE SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND NIPRNET

DEVICE OUTSIDE EDGE OF 5"x5" BOX.

2. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND

NIPRNET CABLE PATHWAYS AND TERMINATIONS.

3. IN INDIVIDUAL OFFICES, MOUNT TV OUTLETS AT 66"AFF. IN OPEN OFFICES

MOUNT TV OUTLETS AT 72"AFF. LOCATE TV OUTLET ADJACENT TO THEIR

RESPECTIVE POWER RECEPTACLE.

4. FLOOR BOX TO BE LIMITED TO SERVING A MAXIMUM OF 6 WORK AREAS (ALL

PART OF ONE FURNITURE CLUSTER). PROVIDE EACH DESK AREA WITH TWO

NIPR AND TWO SIPR DATA OUTLETS.

5. MOUNT DATA OUTLETS ADJACENT TO POWER OUTLETS, WITH A SEPARATION

DISTANCE OF 6" BETWEEN THE EDGE OF DATA AND POWER FACEPLATES.

6. IN CONFERENCE ROOMS, FLOOR BOXES TO BE ALIGNED NEAR EDGE OF

TABLES AND WITH TABLE LEGS FOR CABLE MANAGEMENT OF POWER, DATA,

AND A/V DEVICES.

7. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST

REQUIREMENTS.

1 CEILING MOUNTED OUTLET. MOUNT 3-6 INCHES ABOVE THE CEILING.

2 SURFACE MOUNT ALL TELECOMMUNICATIONS DEVICES WITHIN THIS ROOM.

3 OUTLETS TO BE LOCATED IN THE FIRE ALARM CONTROL PANEL. COORDINATE

DURING INSTALLATION.

4 OUTLETS TO BE LOCATED IN THE BAS PANEL. COORDINATE DURING

INSTALLATION.

5 CAT6 CABLE ROUTING SHOWN TO AND FROM FLOOR BOXES WITHIN THIS ROOM

ARE DIAGRAMMATIC. COORDINATE ACTUALLY ROUTING OF CAT6 CABLING

WITHIN FLOOR CABLE PATHWAY SYSTEM IN THE FIELD. REFER TO "WALL TO

ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

J J

J

J

J

J

J

J

J

J

J

J

J

J

OPEN OFFICE

SHARED OFFICE

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

OFFICE 8

OFFICE 9

OFFICE 11

OFFICE 10

CONFERENCE ROOM

JTAC CONTROL ROOM

JTAC

CORRIDOR

MENS RESTROOM

ENTRY VESTIBULE

COVERED AREA

SECURITY

WOMENS RESTROOM

ELECTRICAL

BLUE OPS AREA

MECHANICAL SPACE

COMM

SECURITY BUNK

A 1/

E T

C2

ET401

BREAKROOM

PRINTER

A

B

C

D

E

F

G

21 3 4 5 6 7 8 9

A 1/

E T

S

1- 1/

4" C

S

S

S

S

S

S

1- 1/

4" C

8 S

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:1

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET105

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IR

S T

F

LO

O R

P

LA

N

N E

TW

O

R K

B E

LO

W

F

LO

O R

R O

U

TI

N G

A

R E

A A

JAZ

12794424

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

NETWORK KEYNOTES

KEY PLAN

8'4' 16'0

1. PROVIDE A MINIMUM SEPARATION OF 12" BETWEEN THE NIPR AND SIPR CABLE

TRAYS.

2. BOND CABLE TRAY TO GROUNDING INFRASTRUCTURE. REFER TO THE RISER

DIAGRAMS ON THE ET600 SERIES SHEETS FOR ADDITIONAL INFORMATION.

3. RUN GROUND WIRE WITH THE CABLE TRAY AND BOND GROUND WIRE TO

EACH SECTION OF THE CABLE TRAY. BOND GROUND WIRE TO THE RAISED

GROUND FLOOR.

4. ROUTE SIPRNET AND NIPRNET PATHWAYS FROM OPPOSITE DIRECTIONS,

CROSSING AT 90 DEGREES BUT NEVER TOUCHING.

5. FOR UNDERFLOOR CABLE PATHWAY SYSTEM, COORDINATE FLOOR

PENETRATIONS AND FLOOR PEDESTAL LOCATIONS WITH OTHER CONTRACTORS

AND MODULAR FURNITURE LAYOUT. PROVIDE ALL FLEXIBLE CONDUIT BOXES

AND MATERIALS AS NECESSARY FOR CONNECTIONS.

6. REFER TO SHEET ET102 FOR LOCATION AND QUANTITY OF DATA DEVICES AND

DATA BOXES.

7. PROVIDE A MINIMUM OF 2" OF FREE SPACE BETWEEN THE TOP OF THE CABLE

TRAY SIDE RAILS AND THE UNDERSIDE OF THE STRINGERS.

8. BOND ALL METAL PARTS OF THE ACCESS FLOOR TO GROUND. FOLLOW THE

ACCESS FLOOR MANUFACTURER'S GUIDELINES AND ALL APPLICABLE CODES.

9. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST

REQUIREMENTS.

10. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND

NIPRNET CABLE PATHWAYS AND TERMINATIONS.

A B

PLAN

NORTH

1 ACCESS PATHWAY FROM CEILING TO BELOW FLOOR CONCEALED IN WALL.

2 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF SECURE

1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT NEAR

NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4" CONDUITS

REQUIRED FOR PATHWAY ACCESS WITHIN WALL CAVITY. NOTE QUANTITY OF

CONDUITS ARE BASED ON A MAXIMUM OF NINE CAT6 CABLES (WITH AN OUTER

DIAMETER OF 0.265) PER CONDUIT, AND 40% CONDUIT FILL. REFER TO "WALL

TO ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.

3 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF NON-SECURE

1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT NEAR

NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4" CONDUITS

REQUIRED FOR PATHWAY ACCESS WITHIN WALL CAVITY. NOTE QUANTITY OF

CONDUITS ARE BASED ON A MAXIMUM OF NINE CAT6 CABLES (WITH AN OUTER

DIAMETER OF 0.265) PER CONDUIT, AND 40% CONDUIT FILL. REFER TO "WALL

TO ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.

1/8" = 1'-0" A1

FIRST FLOOR PLAN - NETWORK BELOW FLOOR ROUTING - AREA A

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

CORRIDOR

FIRE ALARM ROOM

TRASH/MANT.

BREAKROOM

OFFICE 6

TEAM ROOM

PURPLE OPS AREA

GREEN OPS AREA

CONFERENCE ROOM

OFFICE 5

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 1

CO OFFICE

307 OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

CO OFFICE

OFFICE 8

TEAM ROOM

BREAKROOM

CONFERENCE ROOM

CONFERENCE ROOM

PRINTER

RECEPTION

CORRIDOR

A 1/

E T

A

B

C

D

E

F

8 9 10 11 12 13 14

A 1/

E T

S

S

S

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:1

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET106

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IR

S T

F

LO

O R

P

LA

N

N E

TW

O

R K

B E

LO

W

F

LO

O R

R O

U

TI

N G

A

R E

A B

JAZ

12794425

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

NETWORK KEYNOTES

KEY PLAN

8'4' 16'0

A B

PLAN

NORTH

1. PROVIDE A MINIMUM SEPARATION OF 12" BETWEEN THE NIPR AND SIPR

CABLE TRAYS.

2. BOND CABLE TRAY TO GROUNDING INFRASTRUCTURE. REFER TO THE RISER

DIAGRAMS ON THE ET600 SERIES SHEETS FOR ADDITIONAL INFORMATION.

3. RUN GROUND WIRE WITH THE CABLE TRAY AND BOND GROUND WIRE TO

EACH SECTION OF THE CABLE TRAY. BOND GROUND WIRE TO THE RAISED

GROUND FLOOR.

4. ROUTE SIPRNET AND NIPRNET PATHWAYS FROM OPPOSITE DIRECTIONS,

CROSSING AT 90 DEGREES BUT NEVER TOUCHING.

5. FOR UNDERFLOOR PATHWAY SYSTEM, COORDINATE FLOOR PENETRATIONS

AND FLOOR PEDESTAL LOCATIONS WITH OTHER CONTRACTORS AND

MODULAR FURNITURE LAYOUT. PROVIDE ALL FLEXIBLE CONDUIT BOXES AND

MATERIALS AS NECESSARY FOR CONNECTIONS.

6. REFER TO SHEET ET102 FOR LOCATION AND QUANTITY OF DATA DEVICES

AND DATA BOXES.

7. PROVIDE A MINIMUM OF 2" OF FREE SPACE BETWEEN THE TOP OF THE CABLE

TRAY SIDE RAILS AND THE UNDERSIDE OF THE STRINGERS.

8. BOND ALL METAL PARTS OF THE ACCESS FLOOR TO GROUND. FOLLOW THE

ACCESS FLOOR MANUFACTURER'S GUIDELINES AND ALL APPLICABLE CODES.

9. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST

REQUIREMENTS.

10. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND

NIPRNET CABLE PATHWAYS AND TERMINATIONS.

1 ACCESS PATHWAY FROM CEILING TO BELOW FLOOR CONCEALED IN WALL.

2 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF SECURE

1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT NEAR

NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4" CONDUITS

REQUIRED FOR PATHWAY ACCESS WITHIN CAVITY. NOTE THE QUANTITY OF

CONDUITS IS BASED ON A MAXIMUM OF NINE CAT6 CABLES, (WITH AN OUTER

DIAMETER OF 0.265), AND 40% CONDUIT FILL. REFER TO "WALL TO ACCESS

FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.

3 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF NON-

SECURE 1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT

NEAR NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4"

CONDUITS REQUIRED FOR PATHWAY ACCESS WITHIN WALL CAVITY. NOTE

THE QUANTITY OF CONDUITS IS BASED ON A MAXIMUM OF NINE CAT6 CABLES,

(WITH AN OUTER DIAMETER PF 0.265), AND 40% CONDUIT FILL. REFER TO

"WALL TO ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL

REQUIREMENTS.

1/8" = 1'-0" A1

FIRST FLOOR PLAN - NETWORK BELOW FLOOR ROUTING - AREA B

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

COMM

A1

ET401

SECURITY SYSTEM IDS/ACS

TMGB

PROTECTED ENTRANCE TERMINAL

FOR INCOMING OSP COPPER LINES

TP

NIPR RACK #1

(FRONT)

NIPR RACK #2

(FRONT)

NIPR RACK #3

(FRONT)

SIPR RACK #1

(FRONT)

SIPR RACK #2

(FRONT)

SIPR RACK #3

(FRONT)

48"

4'

TYPICAL - 12" LADDER

RUNWAY

TYPICAL - PLYWOOD

BACKBOARD

TYPICAL - SPACE FOR

EQUIPMENT RACK

C

PROTECTED ENTRANCE TERMINAL

FOR INCOMING OSP COPPER LINES

TMGB

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:3

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET401

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

E N

LA

R

G E

D P

LA

N

S

JAZ

12794426

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

GENERAL NOTES

NETWORK KEYNOTES

1/2" = 1'-0" (ET101)

C2

COMM ROOM 107 - ENLARGED PLAN

PLAN

NORTH

2'1' 4'0

A2

COMM ROOM 107 - ISOMETERIC

NTS

1 HIGH VOLUME CABLE PATHWAYS WITH INTEGRAL FIRESTOPPING AND SOUND

ATTENUATION. BASIS OF DESIGN SHALL BE THE STI EZ PATH SERIES 44+.

2 FOUR 4" CONDUITS ROUTED BELOW GRADE TO EXISTING UTILITY MANHOLE

AT EVERETTE CREEK RD. SEE SHEETS ES101 AND ET601 FOR ADDITIONAL

INFORMATION. FIELD COORDINATE LOCATIONS OF CONDUITS PRIOR TO

INSTALLATION.

3 LOCATION OF KRONE BLOCKS.

4 4" CONDUIT ROUTED UNDERGROUND TO ANTENNA PAD. FIELD COORDINATE

LOCATIONS OF CONDUITS PRIOR TO INSTALLATION.

1/4" = 1'-0" (ET401)

A1

COMM ROOM 107 SECTION - PLAN WEST

0 2' 4' 8'

1. MAINTAIN A MINIMUM OF 12" OF SEPARATION BETWEEN SIPR EQUIPMENT AND

NIPR WIRELINES THAT DIRECTLY LEAVE COMM ROOM 107.

2. MAINTAIN A MINIMUM OF 6" OF SEPARATION BETWEEN SIPR CABLES AND NIPR

CABLES THAT DIRECTLY LEAVE COMM ROOM 107.

3. PRIOR TO ROUGH-IN, COORDINATE MOUNTING HEIGHT AND LOCATION OF

ELECTRICAL DEVICES ONSITE TO AVOID POTENTIAL CONFLICTS WITH TELECOM

PASSIVE INFRASTRUCTURE.

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

1 1/4" CONDUIT WITH (4) 4

PAIR CATEGORY 6 CABLE

UP TO CABLE TRAY

TYPICAL -

DUAL MOLDED MODULAR 8P8C FLAT

JACK SET WITH S310 TERMINATIONS

TO BE PRINTED CIRCUIT BOARD THAT

CAN BE INSTALLED FROM FRONT OR

BACK OF FACEPLATE

TELECOMMUNICATION

OUTLET SINGLE GANG

FACEPLATE WITH (2)

MODULAR OPENINGS

MINIMUM 5" SQUARE,

2-7/8" DEEP DOUBLE GANG

JUNCTION BOX WITH PLASTER

RING FOR CONNECTION OF

SINGLE GANG FACEPLATE

LABEL OUTLET ACCORDING

TO LOCAL STANDARDS

1 1/4" CONDUIT WITH (4) 4

PAIR CATEGORY 6 CABLE

UP TO CABLE TRAY

TYPICAL -

DUAL MOLDED MODULAR 8P8C FLAT

JACK SET WITH S310 TERMINATIONS

TO A PRINTED CIRCUIT BOARD THAT

CAN BE INSTALLED FROM FRONT OR

BACK OF FACEPLATE

TELECOMMUNICATION

OUTLET SINGLE GANG

FACEPLATE WITH (2)

MODULAR OPENINGS

MINIMUM 5" SQUARE,

2-7/8" DEEP DOUBLE GANG

JUNCTION BOX WITH PLASTER

RING FOR CONNECTION OF

SINGLE GANG FACEPLATE

LABEL OUTLET ACCORDING

TO LOCAL STANDARDS

3' -1

0" T

O F

LO

O

R , U

O N

1" CONDUIT WITH

(1) 4 PAIR CATEGORY 6

CABLE TO CABLE TRAY

8P8C VOICE JACK

TELECOMMUNICATION

OUTLET SINGLE GANG

FACEPLATE WITH

SINGLE VOICE OPENING

MINIMUM 2"x4"x2-1/8"

DEEP JUNCTION BOX

WITH SINGLE GANG

EXTENSION

MOUNTING EAR

MOUNTING EAR

VOICE

LABEL OUTLET

ACCORDING TO

LOCAL STANDARDS

NETWORK COLOR MATRIX

NETWORK COLOR JACKET

COLOR

NOTES

NIPRNET GREEN -

SIPRNET RED -

VOICE GREEN FOR TELEPHONE NOT ROUTED THROUGH THE VOIP DATA SWITCH.

1 1/4" CONDUIT UP TO

CABLE TRAY

TYPICAL -

DUPLEX SC

CONNECTORS,

NON-KEYED,

COLOR-CODED

TELECOMMUNICATION

OUTLET SINGLE GANG

FACEPLATE WITH (2)

MODULAR OPENINGS

MINIMUM 5" SQUARE,

2-7/8" DEEP DOUBLE GANG

JUNCTION BOX WITH

PLASTER RING FOR

CONNECTION OF SINGLE

GANG FACEPLATE

LABEL OUTLET

ACCORDINGLY

MODULAR SPACE,

1/2 SIZE SLOPED INSERT

SIDE VIEW ISOMETRIC VIEW

FLOOR OUTLET NOTES:

1. BACKBOX TO BE RATED FOR FLOOR CONSTRUCTION (WOOD, CONCRETE, RAISED FLOOR, ETC.) OF LOCATION WHERE

INSTALLED.

2. FOR BACKBOX LOCATED IN ACCESS FLOORING SYSTEM, COORDINATE BACKBOX AND FACEPLATE WITH ACCESS

FLOORING SYSTEM PRIOR TO INSTALLATION.

3/4" KNOCKOUT

1-PLACE EACH SIDE

1" KNOCKOUT

4-PLACES EACH SIDE

TYPICAL -

DUAL MOLDED MODULAR 8P8C FLAT

JACK SET WITH S310 TERMINATIONS TO A PRINTED

CIRCUIT BOARD THAT CAN BE INSTALLED FROM

FRONT OR BACK OF FACEPLATE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:3

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET501

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

TE

LE

C O

M M

U N

IC

A

T

IO

N S

D E

TA

IL

S

JAZ

12794427

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

NTS

C1

SECURE OUTLET DETAIL (S)

NTS

C2

NON-SECURE OUTLET DETAIL

NTS

A1

SINGLE VOICE (POTS) OUTLET DETAIL

NTS

C3

SECURE DATA OUTLET DETAIL (FO)

JAS

NTS

A2

FLOOR OUTLET - STANDARD TELE/DATA DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

PROVIDE BONDING LUG AT

EACH END OF EACH CABLE

TRAY SECTION AND CONNECT

THE CABLE TRAY GROUND

WIRE AT EACH LOCATION

BELL BONDING BUSHING

AT END OF CONDUIT

BEFORE CABLE TRAY.

PROVIDE #6 BONDING WIRE

FROM BUSHING TO CABLE

TRAY GROUND WIRE

CONDUIT WITH DATA, VOICE

OR CATV CABLE(S)

PROVIDE #2 AWG COPPER

GROUND CONDUCTOR

THE ENTIRE LENGTH OF

THE CABLE TRAY. ATTACH

GROUND CONDUCTOR ON

OUTSIDE OF THE CABLE TRAY

PROVIDE PROTECTIVE COATING

OR SLEEVE OVER ALL EXPOSED

THREADS AND SIMILAR SURFACES,

WHEN PROVIDED, FROM TOP OF

TRAY TO 12" ABOVE THE TRAY

PROVIDE BONDING LUG AT EACH

END OF EACH CABLE TRAY SECTION

AND CONNECT THE CABLE TRAY

GROUND WIRE AT EACH LOCATION

PROVIDE SUPPORT CABLES OR

THREADED ROD ON EACH SIDE

OF THE CABLE TRAY, SIZE AND

SPACING, AS RECOMMENDED BY

CABLE TRAY MANUFACTURER

REQUIREMENTS FOR FULL CABLE

TRAY AND SEISMIC REQUIREMENTS

DATA, VOICE AND CATV

CABLES IN CABLE TRAY

SUPPORT HANGERS

CABLE TRAY SYSTEM

CABLE TRAY SYSTEM

DATA, VOICE AND CATV

CABLES IN CABLE TRAY

PROVIDE #2 AWG COPPER

GROUND CONDUCTOR THE

ENTIRE LENGTH OF THE

CABLE TRAY. ATTACH GROUND

CONDUCTOR ON OUTSIDE OF

THE CABLE TRAY

PROVIDE CONTINUOUS BONDING

THROUGHOUT CABLE TRAY SYSTEM

ON THE EXTERIOR OF THE TRAY

USING TRAY CLAMPS. BOND CABLES

AT "T"S AND TRAY SEPARATED BY

ELEVATION

PROVIDE BONDING LUG AT EACH

TRANSITION IN CABLE TRAY SECTION

AND CONNECT THE CABLE TRAY

GROUND WIRE AT EACH LOCATION

TELEPHONE TERMINAL

BOARD

GROUND WIRE

TO EQUIPMENT

1/4" THICK BY 24"

LONG COPPER

GROUND BUS

STAND-OFF INSULATOR

MOUNTED TO WALL

GROUND WIRE

TO EQUIPMENT

CABLE TRAY ABOVE ADJACENT

CEILINGS AND CORRIDORS.

SEE PLANS FOR SIZES AND

ROUTING INFORMATION

WALL PHONE

FLOOR

CEILING

W A

LL

CCTV,

OUTLET MOUNT

PROVIDE CABLE IN CONDUIT

FOR EACH OUTLET

LOCATION TO CABLE TRAY

UNDERFLOOR CABLE TRAY. SEE PLANS

FOR SIZE AND ROUTING INFORMATION

MOUNTED IN RECESSED FLOOR BOX.

DATA OUTLET TO BE MOUNTED

PERPENDICULAR OR AT AN ANGLE TO

PROTECT JACK AND CABLE

CONNECTIONS. DATA OUTLET

MOUNT ADJACENT TO POWER OUTLET

DATA AND VOICE OUTLET.

MOUNT TO MATCH ADJACENT

POWER OUTLET

FINISHED FLOOR

9"

#6 AWG MINIMUM GROUND

WIRE TO METAL CONDUITS

IN ROOM

GROUND WIRE TO EXPOSED

BUILDING COLUMN IN ROOM

IF PRESENT

#4 AWG MINIMUM GROUND

WIRE TO PANELBOARD

ENCLOSURE IN ROOM

#2 AWG MINIMUM GROUND

WIRE TO LADDER RUNWAY(S)

IN ROOM

STAND-OFF INSULATOR MOUNTED

TO WALL. TYPICAL FOR TWO

LOCATIONS

#4 AWG MINIMUM GROUND

WIRE TO PROTECTIVE

ENTRANCE TERMINALS IN

ROOM IF PRESENT

COPPER TMGB SIZE:

4" HIGH BY 1/4" THICK

BY 24" LONG MINIMUM

#2/0 AWG MINIMUM GROUND

WIRE TO BUILDING MAIN

ELECTRICAL SERVICE

#6 AWG MINIMUM

GROUND WIRE TO

UNDERGROUND

CONDUIT STUB-UPS

#6 AWG MINIMUM

GROUND WIRE TO

BUILDING OUTSIDE

PLANT CONDUITS

PROVIDE TWO HOLE BOLTED CONNECTORS

WITH GROUND RATED BELLEVILLE WASHERS

BETWEEN BUS AND CONDUCTOR. PROVIDE

CONDUCTOR GREASE BETWEEN BUS AND

CONNECTIONS. PROVIDE FULL WRAP STRAP

CONNECTORS. CLAMPING OF THE STRAPS

SHALL BE WITH FULL SURFACE CLAMPING

TOOL TO INSURE EVEN COMPRESSION

AROUND THE CABLE

TMGB GENERAL NOTE:

1. PROVIDE GROUNDING IN ACCORDANCE WITH TIA 607.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:3

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET502

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

TE

LE

C O

M M

U N

IC

A

T

IO

N S

D E

TA

IL

S

JAZ

12794428

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

NTS

C1

TYPICAL CABLE TRAY MOUNTING AND BONDING DETAIL

NTS

C4

TYPICAL TMGB SIDE VIEW DETAIL

NTS

A1

TYPICAL OUTLET RISER MOUNTING DETAIL

NTS

A3

TELECOMMUNICATION MAIN GROUND BAR (TMGB) DETAIL

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

FIRE RATED WALL

BEING PENETRATED

CABLE TRAY

FIRE RATED RECTANGULAR

THROUGH-WALL CABLE WAY.

SIMILAR TO SPECIFIED

TECHNOLOGY INC. (STI) SERIES

44 AS REQUIRED FOR EACH

PENETRATION

PROVIDE BONDING LUG AT EACH

END OF EACH CABLE TRAY SECTION

AND CONNECT THE CABLE TRAY

GROUND WIRE AT EACH LOCATION

PROVIDE SUPPORT CABLES OR

THREADED ROD ON EACH SIDE

OF THE CABLE TRAY, SIZE AND

SPACING, AS RECOMMENDED BY

CABLE TRAY MANUFACTURER

REQUIREMENTS FOR FULL CABLE TRAY

CABLE TRAY

1 1/4" CONDUIT UP TO

CABLE TRAY

TYPICAL -

DUAL MOLDED MODULAR 8P8C FLAT

JACK SET WITH S310 TERMINATIONS

TO A PRINTED CIRCUIT BOARD THAT

CAN BE INSTALLED FROM FRONT OR

BACK OF FACEPLATE

TELECOMMUNICATION

OUTLET SINGLE GANG

FACEPLATE WITH (2)

MODULAR OPENINGS

MINIMUM 5" SQUARE,

2-7/8" DEEP DOUBLE GANG

JUNCTION BOX WITH PLASTER

RING FOR CONNECTION OF

SINGLE GANG FACEPLATE

LABEL OUTLET ACCORDING

TO LOCAL STANDARDS

USE HOOK AND LOOP STRIPS TO

SECURE CABLES TO RUNWAY

VERTICAL WALL BRACKET

RUNWAY FOOT KIT

BONDING BUSHING

FLOOR SLAB

EQUIPMENT BONDING

CABLE

CONNECTOR

CONDUIT SLEEVES OR

CONDUITS THRU FLOOR SLAB.

NUMBER OF CONDUIT PER

RISER DIAGRAM

TELECOMMUNICATIONS CABLES

PER RISER DIAGRAM

CABLE RUNWAY

1 1/2" METAL FRAMING

CHANNEL ANCHORED

TO WALL 4/0" O.C.

WALL

SECURELY ANCHOR RUNWAY

FOOT TO FLOOR

NOTES THIS DETAIL:

1. FIRE STOP ALL PENETRATIONS PER SPECIFICATIONS.

2. CABLE RUNWAY TO BE INSTALLED FROM FLOOR TO CEILING.

VERTICAL RUNWAY

SPLICE KIT

CABLE RUNWAY

RUNWAY BEND/

SWIVEL END SPLICE

CABLE RADIUS DROP TO

MAINTAIN PROPER BEND

RADIUS OF CABLES

RUNWAY SIDE MOUNTINGCABLE RADIUS DROP

NOTES THIS DETAIL:

1. ALL CONNECTIONS HARDWARE, PARTS AND PIECES TO BE OF THE SAME MANUFACTURER AS THE CABLE RUNWAY AND APPROVED BY THE MANUFACTURER AS APPROPRIATE FOR THE APPLICATION.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/6

/2

:4

:3

P M

C rv t\

\1

-E

-C E

N T

R A

L P

-1

M A

R

IN

E H

Q je re m y .f o rr e s t.

rv t

ET503

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

TE

LE

C O

M M

U N

IC

A

T

IO

N S

D E

TA

IL

S

JAZ

12794429

EC DJF

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

NTS

C1

TYPICAL CABLE TRAY WALL PENETRATION DETAIL

NTS

C3

IPTV/DDC/FACP/WAP OUTLET DETAIL

NTS

A1

CABLE - TELECOMMUNICATIONS ROOM VERTICAL RUNWAY MOUNTING DETAIL

NTS

A3

TYPICAL TELECOMMUNICATION ROOM RUNWAY CONNECTIONS DETAIL

JAS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

PROVIDE 1 1/2" AV CONDUIT TO

NEAREST NIPR CABLE TRAY

PROVIDE 1 1/4" DATA CONDUIT TO

THEIR NEAREST RESPECTIVE

NIPR/SIPR CABLE TRAY

AVNIPR

DATA

SEE AV PLANS FOR

MOUNTING HEIGHT

TYPICAL -

COMMUNICATION CONDUITS SHALL HAVE NO

MORE THAN A MAXIMUM OF TWO 90 DEGREE

BENDS. PROVIDE A PULL STRING FOR ALL

EMPTY CONDUITS.

SIPR

DATA

AV…

This is the start of the file's text. The full file is on GovTribe.