P-1395-E-Revision 1_2020-08-05.pdf
PDF 6 MB Posted
- Solicitation number
- N40085-19-R-9148
About this file
This federal solicitation is seeking proposals for the construction of Marine Raider Regiment Headquarters facilities at Marine Corps Air Station Camp Lejeune. The scope of work includes constructing 2,788 square meters of single-story steel frame buildings with brick veneer and metal roofs, as well as miscellaneous supporting structures, utilities, parking, roadways, sidewalks, running trails and site work. Special construction features are required for soil surcharge loads and stormwater management. Electrical, mechanical, information, and site work systems will be provided. The Department of Defense and federal sustainability requirements must be followed. Proposals are solicited from contractors by the Naval Facilities Engineering Command on behalf of the Department of the Navy.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REF REFREFREF
J
J
J
J
J
J
J
J
J
J
J
J
ACS
J
J
J
J
J
J
J
J
J
J
J J
J
J
J
J
J
J
J
J J J
J J
OPEN OFFICE
SHARED OFFICE
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
OFFICE 8
OFFICE 9
OFFICE 11
OFFICE 10
CONFERENCE ROOM
JTAC CONTROL ROOM
JTAC
CORRIDOR
MENS RESTROOM
ENTRY VESTIBULE
COVERED AREA
SECURITY
WOMENS RESTROOM
ELECTRICAL
BLUE OPS AREA
MECHANICAL SPACE
COMM
EWC
SECURITY BUNK
GFI
GFI
GFI
GFI
A 1/
E P
EP401
B1
TP
RP1-3
RP1-4
RP1-5
RP1-6
RP1-7
RP1-8
RP1-9
RP1-10
RP1-16 RP1-17
RP1-18
RP6-4
RP6-3
RP6-2
RP6-1
RP3-35
RP3-30
RP3-33
RP3-31
RP1-21 RP1-22
MP2-24
MP2-22
GFI
GFI
WP
WP
WP
RP3-32
1 1
RP6-21,23 RP6-22,24
EP402
C2
PRINTER
BREAKROOM
RP1-25
RP1-27
RP2-29
RP2-31
RP2-33
RP2-35
A
B
C
D
E
F
G
21 3 4 5 6 7 8 9
EP401
A3
RP1-20
A 1/
E P
RP1-15
CLOSET
RP6-17 RP6-18 RP6-19 RP6-20
RP6-13 RP6-14 RP6-15 RP6-16
RP6-27
AR
AR
AR AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR AR
AR
AR
AR
AR
AR
AR
AR
AR
AR AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
RP6-13 RP6-14 RP6-15 RP6-16
RP6-17 RP6-18 RP6-19 RP6-20
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR AR
AR AR
RP1-23
RP1-1
RP1-2
RP2-21,23
RP2-25,27
RP2-17,19
RP2-18,20
RP2-13,15
RP2-14,16
RP2-9,11
RP2-5,7
RP2-1,3
RP2-2,4
RP2-6,8
RP2-10,12
AR
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:4
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
EP101
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
F
IR
S T
F
LO
O R
P
LA
N
P O
W E
R
A R
E A
A
EC
12794402
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
POWER KEYNOTES
KEY PLAN
8'4' 16'0 1/8" = 1'-0" A1
FIRST FLOOR PLAN - POWER - AREA A
A B
PLAN
NORTH
1. REFER TO PANEL SCHEDULES FOR CONDUIT AND WIRE SIZES.
2. REFER TO AUXILIARY SYSTEMS PLAN, EY101, FOR ADDITIONAL ACCESS
CONTROL SYSTEM DETAILS.
3. RECEPTACLES WITH SUBSCRIPT "AR" MUST HAVE A "CONTROLLED" MARKING
THAT COMPLY WITH NEC ARTICLE 406.3(E) "CONTROLLED RECEPTACLE
MARKING".
4. TYPICAL - AUTOMATIC RECEPTACLE CONTROL REPLAY MODULE TO BE
CONNECTED TO THE NEAREST OCCUPANCY SENSOR WITHIN THE
ROOM/AREA IT RESIDES. WHEN THE ROOM/AREA IS VACANT, OCCUPANCY
SENSOR WILL BE RESPONSIBLE FOR AUTOMATICALLY TURNING OFF THE
RECEPTACLES WITH SUBSCRIPT "AR".
5. FIELD ADJUST CONVENIENCE RECEPTACLES SHOWN SO THAT AT LEAST ONE
RECEPTACLE IS NO MORE THAN 2-3 FT FROM THE DEFIBRILLATOR WITHIN ITS
RESPECTIVE ROOM.
6. PROVIDE 6" LINEAR SEPARATION BETWEEN POWER AND DATA NETWORK
CABLES.
7. FOR FURNITURE CONNECTIONS, NO MORE THAN THREE CUBICLES ARE TO BE
CONNECTED TO A CIRCUIT.
1 30A DISCONNECT SWITCH FOR OVERHEAD DOOR.
2 RECEPTACLE FOR TIME ZONE CLOCK. COORDINATE MOUNTING HEIGHT WITH
CLOCK LOCATION SUCH THAT RECEPTACLE IS HIDDEN BEHIND CLOCK.
3 FOR THE OPEN OFFICE AREA - CONNECT EACH OF THE FOLLOWING CIRCUITS
TO AN AUTOMATIC RECEPTACLE CONTROL REPLAY MODULE THAT MEETS
THE AUTOMATIC RECEPTACLE REQUIREMENT OF ASHRAE 90.1:
* RP2-3, RP2-4, RP2-7, RP2-8, RP2-11, RP2-12, RP2-15, RP2-16, RP2-19,
RP2-20, RP2-23 AND RP2-27
EACH RECEPTACLE CONTROLLER MUST BE CAPABLE OF COMMUNICATING
WITH THE OCCUPANCY SENSOR, WITHIN ITS RESPECTIVE AREA, THRU
WIRELESS TECHNOLOGY.
4 FOR OPEN OFFICE AREA - CONTRACTOR TO WIRE 50% OF THE RECEPTACLES
IN EACH MODULAR FURNITURE SYSTEM TO AN AUTOMATIC CONTROL
RECEPTACLES CIRCUIT TO ENSURE AREA IS IN COMPLIANCE WITH THE
AUTOMATIC RECEPTACLE REQUIREMENT OF ASHRAE 90.1.
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
R E
F
R E
F R
E F
R E
F
FACP
J
J
J
J
J J
J J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
JJ
J
J
CORRIDOR
FIRE ALARM ROOM
TRASH/MANT.
BREAKROOM
OFFICE 6
TEAM ROOM
PURPLE OPS AREA
GREEN OPS AREA
CONFERENCE ROOM
OFFICE 5
OFFICE 4
OFFICE 3
OFFICE 2
OFFICE 1
CO OFFICE
OFFICE 1
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
CO OFFICE
207OFFICE 8
TEAM ROOM
BREAKROOM
CONFERENCE ROOM
CONFERENCE ROOM
PRINTER
RECEPTION
CORRIDOR
A 1/
E P
RP3-1
RP3-2
RP3-3
RP3-4
RP3-5
RP3-6
RP3-10
RP3-12RP3-13
RP3-16
RP3-17
RP3-15
RP4-1
RP4-2
RP4-3
RP4-4
RP4-5
RP4-7
RP4-8
RP4-9
RP4-11
RP4-14
RP4-15
RP4-16
RP4-17
RP4-18
RP4-19 RP4-20
RP4-21
RP4-22
RP4-23
RP4-24
RP4-29
RP4-30
RP4-31
RP4-32
RP3-11
ANT
WP WP
WP
RP5-20,22
1 1
RP5-19,21
ANT-1 ANT-2
WPWP
ANT-4
ANT-3
WP
WP
ANT-6
WP WP
EP402
A1
EP402
A3
A
B
C
D
E
F
8 9 10 11 12 13 14
RP4-34
RP3-8
RP3-14
RP4-10
RP4-12
A 1/
E P
RP3-9
GP-2
RP4-13
RP3-22
RP3-26 RP3-27
RP3-23 RP3-24
RP3-28 RP3-29
RP3-25
RP5-13 RP5-14 RP5-15 RP5-16 RP5-17 RP5-18
RP5-7 RP5-8 RP5-9 RP5-10 RP5-11 RP5-12
RP5-1 RP5-2 RP5-3 RP5-4 RP5-5 RP5-6
2 2
ANT-5
GFI
RP4-25
AR
AR
AR
AR
AR
AR
AR
AR
AR AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR AR
AR
AR AR
AR
AR
AR
AR
WP
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR AR
AR
AR
AR
AR
AR AR
AR AR
AR AR
AR AR
AR AR
AR
AR AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
AR
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:5
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
EP102
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
F
IR
S T
F
LO
O R
P
LA
N
P O
W E
R
A R
E A
B
EC
12794403
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
POWER KEYNOTES
KEY PLAN
8'4' 16'0 1/8" = 1'-0" A1
FIRST FLOOR PLAN - POWER - AREA B
A B
PLAN
NORTH
1 30A DISCONNECT SWITCH FOR OVERHEAD DOOR.
2 RECEPTACLE FOR TIME ZONE CLOCK. COORDINATE MOUNTING HEIGHT WITH
CLOCK LOCATION SUCH THAT RECEPTACLE IS HIDDEN BEHIND CLOCK.
1. REFER TO PANEL SCHEDULES FOR CONDUIT AND WIRE SIZES.
2. REFER TO AUXILIARY SYSTEMS PLAN, EY101, FOR ADDITIONAL ACCESS
CONTROL SYSTEM DETAILS.
3. RECEPTACLES WITH SUBSCRIPT "AR" MUST HAVE A "CONTROLLED" MARKING
THAT COMPLY WITH NEC ARTICLE 406.3(E) "CONTROLLED RECEPTACLE
MARKING".
4. TYPICAL - AUTOMATIC RECEPTACLE CONTROL REPLAY MODULE TO BE
CONNECTED TO THE NEAREST OCCUPANCY SENSOR WITHIN THE
ROOM/AREA IT RESIDES. WHEN THE ROOM/AREA IS VACANT, OCCUPANCY
SENSOR WILL BE RESPONSIBLE FOR AUTOMATICALLY TURNING OFF THE
RECEPTACLES WITH SUBSCRIPT "AR".
5 FIELD ADJUST CONVENIENCE RECEPTACLES SHOWN SO THAT AT LEAST ONE
RECEPTACLE IS NO MORE THAN 2-3 FT FROM THE DEFIBRILLATOR WITHIN ITS
RESPECTIVE ROOM.
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
SAPL
ING
QL-C
QL-C
QL-C
FO P
aint bo/c ut
EOI
EOIEOI
QL-C
QL-
C
EVERE
TT CR
EEK R
D ASPHALT SURFACE
ASP
H
ALT
S U R
FAC
E
7'
CH
AIN
LINK
W/B
ARB
ED
WIR
E F
ENC
E
7' CHAINLINK W/BARBE WIRE FENCE
C O N C W
ALK
META
L SIG
N
ASPH
ALT P
ATH
TMH
RIM=
37.5
TCAB #FOC69-02 48G10F
TMH
RIM=36.52
L/P
L/P
P/P
P/P P/P P/P
L/P
EMH
WV
TON=
37.91
WOODS
WOODS
ROAD (GRAVEL)
EG
T
E
O U
TS
ID
E S W
EP
T P A
TH
IN
S
ID
E S W E P T P A
TH
.1 ft
.0 ft
7.
ft
.0 f t
.0 f t
8.
ft
J
J
J
J
J
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
U P
U P
U P
U P
U P
U C
U C
U C
U C
U C
U C
U C
UC
UC
UC
U C
U C
U C
U C
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
U P
U P
U P
U P
U P
U P
U P
UC
UC
UC
UC UCUC UC UC UC
U P
U P
U P
U P
U P
U P
U P
U P
UP UP
75KW GENERATOR
500KVA TRANSFORMER
AND UTILITY METER
S1
S1
S1
S1
S1
2-5" PVC CONDUIT
2-5" CONDUIT
HANDHOLE
(TYPICAL)
PERIMETER FENCE
FENCE
LOADING, STAGING,
SATELLITE ETC. AREA
FENCE
PERIMETER FENCE
PERIMETER FENCE
ACCESS RO
AD
ACC-1
SEE DETAIL A2 & A4 /EP503
ANT
TO EXISTING
MANHOLE MHRR 114-7
LP1-22
LP1-18
SETBACK
(TYPICAL)
EXISTING
UTILITY POLE
S1 S1
S1
S1
S1
2-5" CONDUIT
TP-23
TP-37
RP5-23
TURNSTILE
SLIDING GATE
GP-10
GP-8
16 17
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:5
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ES101
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
S
IT
E P
LA
N
E
LE
C
TR
IC
A L
EC
12794395
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
ELECTRICAL KEYNOTES
1" = 50'-0" A1
SITE PLAN - ELECTRICAL
50 1000 50 1000
1. FIELD VERIFY NEMA 4X NOTE THAT EACH ENCLOSURE REQUIRE AN 'END USER'S EQUIPMENT CABLING PENETRATION TO BE COORDINATED BETWEEN USMC AND THE ELECTRICAL CONTRACTOR BEFORE FINAL INSTALLATION. COORDINATE ENCLOSURE LOCATIONS WITH OWNER
PRIOR TO INSTALLATION.
2. NEMA 4X TELECOMMUNICATION ENCLOSURES TO BE MOUNTED AT 48" AFG.
3. COORDINATE ALL UNDERGROUND STRUCTURES AND UTILITIES PRIOR TO BEGINNING WORK.
4. COMMUNICATION CONDUIT BENDS SHALL BE SWEEPS WITH A MINIMUM RADIUS OF TEN TIMES THE INTERNAL DIAMETER.
5. NO SECTION OF COMMUNICATION CONDUIT SHALL CONTAIN NO MORE THAN TWO 90 DEGREE BENDS OR EQUIVALENT BETWEEN PULL POINTS.
6. INSTALL MAINTENANCE HOLES WHERE CONDUIT SECTION LENGTH EXCEEDS 400FT.
7. DUCTS TO BE SEALED TO RESIST LIQUID AND GAS INFILTRATION AT BOTH ENDS AND CLEARLY MARKED ON OUTSIDE END.
8. UNDERGROUND CONDUITS TO BE INSTALLED SO THAT A SLOPE EXIST AT ALL POINTS OF THE RUN TO ALLOW DRAINAGE AND PREVENT
ACCUMULATION OF WATER. SLOPE SLEEVES DOWNWARD 0.125IN/FT AWAY FROM BUILDING.
9. UPON ENTERING THE BUILDING TERMINATE ALL OSP COPPER CABLES ON THE PROTECTED ENTRANCE TERMINAL (PET).
10. ALL COPPER AND FIBER TELECOMMUNICATION CABLES SHOWN ON THIS SHEET ARE TO BE OSP RATED.
11. PROVIDE A MINIMUM COMMUNICATION HANDHOLE SIZE OF 4'x4'x4', AND COMMUNICATION MAINTENANCE HOLE SIZE OF 6'x7'x8'. PROVIDE
HANDHOLES WITH ROUND LIDS AND OPEN BOTTOM.
12. UNDERGROUND PORTION SHALL BE ENCASED IN MINIMUM OF 3" OF CONCRETE EXTENDING FROM THE BUILDING ENTRANCE TO OSP
DEMARCATION POINT.
1 ROUTE FOUR 4" CONDUITS BELOW GRADE FROM COMM ROOM TO EXISTING UTILITY MANHOLE AT EVERETTE CREEK RD. FOR CONNECTION DEMARK. INSTALL TWO 3-CELL FABRIC INNER DUCTS IN EACH CONDUIT THAT CONTAIN FIBER CABLES. INSTALL A PULL WIRE INSIDE EACH OF THE INNERDUCTS. REFER TO COMMUNICATIONS RISER DIAGRAM FOR ADDITIONAL INFORMATION. ROUTE ONE SET OF 48 STRANDS OF SINGLEMODE FIBER OPTIC CABLE IN ONE CONDUIT, AND 100 PAIR OF COPPER CABLES IN ANOTHER CONDUIT.
2 ROUTE ONE SET OF 36 STRANDS OF SINGLEMODE FIBER OPTIC CABLE, AND 50 PAIR OF COPPER CABLES BELOW GRADE IN 4" CONDUIT FROM COMM ROOM 107 TO NETWORK SWITCH AT ANTENNA PAD. INSTALL TWO 3-CELL FABRIC INNERDUCTS WITHIN THE CONDUIT. INSTALL A PULL WIRE INSIDE EACH OF THE INNERDUCTS. SEE TELECOMMUNICATION RISER DIAGRAM FOR ADDITIONAL INFORMATION.
3 EXCAVATION NEAR BUILDING TO BE PERFORMED WITH HAND TOOLS OR NON-DESTRUCTIVE TOOLS UNTIL THE FACILITY IS EXPOSED, OR
MAXIMUM DEPTH OF THE INTENDED EXCAVATION IS REACHED.
4 PROVIDE NEMA 4X CABINET FOR 12 PORT NETWORK SWITCH. CABINET TO BE SUPPLIED WITH AN INTEGRAL HANDLE, FOR PHYSICAL LOCKING CAPABILITY, AND MUST BE KEYED FOR TYPICAL CAMP LEJEUNE USMC APPLICATION COPPER CABLES TO TERMINATE ON KRONE BLOCK AND LIGHTNING PROTECTOR TO PROVIDE DIAL TONE. COPPER CABLES TO BE TERMINATED ON RJ45 PATCH PANEL WITHIN NEMA 4X CABINET.
FIBER CABLE TO TERMINATE ON SC TYPE CONNECTORS IN A RACK MOUNTABLE (PCH FDP). NETWORK SWITCH TO BE GOVERNMENT FURNISHED GOVERNMENT INSTALL. REFER TO "EQUIPMENT MOUNTING STRUCTURE" DETAIL ON SHEET EP502.
5 ROUTE EIGHT CATEGORY 6 (CAT6) OUTDOOR RATED WATER BLOCK CABLES IN 1-1/2" CONDUIT BELOW GRADE TO NEMA 4X ENCLOSURE
NOTED IN KEYNOTE 6.
6 PROVIDE NEMA 4X CABINET FOR TERMINATION OF CAT6 CABLES. CABINET TO BE SUPPLIED WITH AN INTEGRAL HANDLE, FOR PHYSICAL LOCKING CAPABILITY, AND MUST BE KEYED FOR TYPICAL CAMP LEJEUNE USMC APPLICATION CABLES TO BE TERMINATED PER BASE TELECOMMUNICATIONS STANDARDS. CABINETS MUST HAVE WEATHERPROOF "WHILE-IN-USE" PATHWAYS FOR USER CABLING SO CABLING CAN FEED GOVERNMENT EQUIPMENT WITH CABINET CLOSED. REFER TO "EQUIPMENT MOUNTING STRUCTURE" DETAIL ON SHEET EP502.
7 LOCATE NOTED TELECOMMUNICATION HANDHOLE A MINIMUM OF 6' FROM BUILDING ENTRANCE.
8 SITE LUMINAIRES NOT APART OF THE BASE BID PACKAGE. ONLY CIRCUIT, FEEDERS, AND CONDUIT TO BE STUBBED UP UNDER BASE BID
PACKAGE TO EDGE OF ACCESS ROADWAY.
9 15KV, 200A, 2-WAY ALUMINUM SECTIONALIZING CABINET.
10 ROUTE TWO DEDICATED 20A, 1-POLE CIRCUITS BELOW GRADE TO EACH CABINET FROM PANEL 'ANT'. ROUTE CONDUIT PARALLEL TO 1-1/2" COMM CONDUIT REFERENCE IN KEYNOTE #6. REFER TO PANELBOARD SCHEDULE 'ANT' FOR CIRCUIT NUMBER, WIRE, AND CONDUIT
INFORMATION.
11 FOR GATE OPERATOR - PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMM) ADJACENT TO GATE OPERATOR LOCATION. ROUTE BELOW GRADE TO GATE OPERATOR SYSTEM AND ELECTRICAL PANEL LOCATED IN ELECTRICAL ROOM 108. COORDINATE ADDITIONAL WIRING
REQUIREMENTS WITH GATE OPERATOR SUPPLIER.
12 FOR CARD READER/INTERCOM NEAR VEHICLE ACCESS GATE - PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMM) UNDER STANCHION LOCATION. ROUTE BELOW GRADE TO ACCESS CONTROL SYSTEM, AND ELECTRICAL PANEL, LOCATED IN COMM ROOM 107. COORDINATE
ADDITIONAL WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER.
13 FOR CARD READER/INTERCOM NEAR MAIN ACCESS GATE - PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMM) NEAR MAIN GATE LOCATION. ROUTE BELOW GRADE TO ACCESS CONTROL SYSTEM, AND ELECTRICAL PANEL, LOCATED IN COMM ROOM 107. COORDINATE
ADDITIONAL WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER.
14 PROVIDE WEATHERPROOF "WHILE IN USE" GFI NEMA 120V, 20A DEDICATED RECEPTACLES MOUNTED ON BOTTOM OF STEEL STRUCTURE AS IDENTIFIED IN KEYNOTE 10. REFER TO "EQUIPMENT MOUNTING STRUCTURE" DETAIL ON SHEET EP502.
15 FEEDER AND CONDUIT TO BE ROUTED TO DISTRIBUTION PANELBOARD 'DP', IN ELECTRICAL ROOM. REFER TO POWER RISER DIAGRAM FOR
ADDITIONAL INFORMATION.
16 FOR CARD READER/INTERCOM - PROVIDE 2" CONDUIT STUB-UP UNDER STANCHION LOCATION. ROUTE BELOW GRADE TO INTERCOM AND ACCESS CONTROL SYSTEM LOCATED IN COMM ROOM 107. COORDINATE ADDITIONAL WIRING REQUIREMENTS WITH STANCHION SUPPLIER.
17 FOR GATE OPERATOR, PROVIDE TWO 1" CONDUIT STUB UPS (1-POWER/1-COMMS) ADJACENT TO GATE OPERATOR LOCATION. ROUTE BELOW GRADE TO OPERATOR SYSTEM, AND TO CIRCUIT SHOWN, LOCATED IN ELECTRICAL ROOM 108. COORDINATE ADDITIONAL WIRING
REQUIREMENTS WITH GATE OPERATOR SUPPLIER.
18 FOR TURNSTILE, PROVIDE TWO 1" CONDUIT STUB-UPS (1-POWER/1-COMMS) ADJACENT TO TURNSTILE LOCATION. ROUTE BELOW GRADE TO GATE OPERATOR SYSTEM, AND CIRCUIT SHOWN, LOCATED IN ELECTRICAL ROOM 108. COORDINATE ADDITIONAL WIRING REQUIREMENTS
WITH TURNSTILE SUPPLIER. N
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
COMMUNICATIONS LEGEND ABBREVIATIONSGENERAL NOTES
TV
A AMPERE
AC ABOVE COUNTER, 42" AFF UNLESS NOTED OTHERWISE
ACS ACCESS CONTROL SYSTEM
ADA AMERICANS WITH DISABILITIES ACR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AL ALUMINUM
1/C ONE CONDUCTOR PER CONDUIT
BMS BALANCED MAGNETIC SWITCH
CB CIRCUIT BREAKER
CKT CIRCUIT
CP CONSOLIDATION POINT
CU COPPER
EF EXHAUST FAN
EMT ELECTRICAL METALLIC TUBING
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FM FREQUENCY MODULATION
FO FIBER OPTIC
GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTION
HACR HEATING AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
J JUNCTION BOX
KWH KILOWATT HOURS
LED LIGHT EMITTING DIODE
MCB MOLDED CASE CIRCUIT BREAKER
MH METAL HALIDE
MLO MAIN LUG ONLY
MTD MOUNTED
MUTOA MULTIUSER TELECOMMUNICATIONS OUTLET ASSEMBLY
NEC NATIONAL ELECTRICAL CODE
NF NON-FUSED
NO. NUMBER
OS OCCUPANCY SENSOR
PH PHASE
PIR PASSIVE INFRARED
PTZ PAN TILT ZOOM CAMERA
RGS RIGID GALVANIZED STEEL
SM SINGLE MODE
TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
UON UNLESS OTHERWISE NOTED
V VOLT
VA VOLTAMPERE
VTC VIDEO TELECONFERENCING
VVD VARIABLE VOLUME DAMPER
W WATTS
WP WATERPROOF
XFMR TRANSFORMER
CONFERENCE ROOM RECESSED FLOOR BOX (WITH FLUSH LIDS) CONTAINING
NON-SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET UNLESS SUBSCRIPT
INDICATES OTHERWISE. NON-SECURE DATA OUTLET SHALL BE LIMITED TO
NIPRNET DATA DEVICES.
CONFERENCE ROOM RECESSED FLOOR BOX (WITH FLUSH LIDS) CONTAINING
SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET UNLESS SUBSCRIPT
INDICATES OTHERWISE. SECURE DATA OUTLET SHALL BE LIMITED TO
SIPRNET DATA DEVICES.
NON-SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET MOUNTED 18" AFF
UNLESS SUBSCRIPT INDICATES OTHERWISE. NON-SECURE DATA OUTLET
SHALL BE LIMITED TO NIPRNET DATA DEVICES.
SECURE DATA WITH FOUR 8P8C JACKS PER OUTLET MOUNTED 18" AFF
UNLESS SUBSCRIPT INDICATES OTHERWISE. SECURE DATA OUTLET SHALL BE
LIMITED TO SIPRNET DATA DEVICES.
NON-SECURE VOICE (POTS) OUTLET MOUNTED 46" AFF UNLESS NOTED
OTHERWISE.
NON-SECURE DATA OUTLETS WITH TWO 8P8C JACKS. OUTLETS TO BE
CENTERED ABOVE FINISHED FLOOR AT THE HEIGHT INDICATED ON THE AREA
AV FLOOR PLANS. REFER TO THE TA-100 SERIES DRAWINGS FOR THE
RESPECTIVE MOUNTING HEIGHT OF EACH OUTLET PRIOR TO ROUGH-IN.
144-PORT FIBER OPTIC DISTRIBUTION PANEL FOR TERMINATION OF
HORIZONTAL AND BACKBONE FIBER OPTIC CABLING.
HORIZONTAL CABLE MANAGEMENT UNITS (CABLE GUIDES).
CONDUIT STUB INTO ROOM.
SIPR CABLE TRAY.
NIPR CABLE TRAY.
S
S
1. JACK SHALL BE LABELED AND COLOR CODED BASED ON THE TYPE OF TRAFFIC THEY HANDLE.
REFER TO "NETWORK COLOR MATRIX" DETAILS ON THE TELECOMMUNICATIONS DETAIL PRIOR
TO INSTALLATION.
2. CONDUITS ENTERING COMM ROOMS THROUGH THE FLOOR SHALL BE INSTALLED SO THAT THEY ARE AT LEAST 1" FROM THE PLYWOOD MOUNTED ON THE WALL AND EXTEND AT LEAST 3" ABOVE
FINISHED FLOOR AND SHALL HAVE A PROTECTIVE BUSHING ON THE END OF THE CONDUIT TO
PROTECT THE CABLING.
3. CONDUITS ENTERING/EXITING COMM ROOMS THROUGH THE WALL OR CEILING SHALL BE
INSTALLED SO THAT THEY ARE 1"-3" FROM THE WALL/CEILING AND SHALL HAVE A PROTECTIVE
BUSHING ON THE END OF THE CONDUIT TO PROTECT THE CABLING.
4. WHERE APPLICABLE, BUNDLING AND SECURING OF CABLES SHALL BE ACCOMPLISHED THRU
USE OF VELCRO TAPE.
5. CLASSIFIED (SIPRNET) AND UNCLASSIFIED (NIPRNET) NETWORKS CANNOT BE IN THE SAME
JACKET REGARDLESS OF CABLE CONSTRUCTION.
6. ALL CABLES SHALL BE PLENUM RATED.
7. TEN FOOT CAT6 DEVICE CABLES SHALL BE PROVIDED TO EQUAL 1.1 TIMES THE NUMBER OF
LOCATION WHERE CAT6 JACKS ARE INSTALLED. EXAMPLE: IF 100 JACK LOCATIONS ARE
INSTALLED THEN PROVIDE 110 DEVICES CABLES (1.1x100).
8. SPARE JACKS SHALL BE PROVIDED TO EQUAL 0.1 TIMES THE TOTAL NUMBER OF SHIELDED CAT6A OR FIBER OPTIC OUTLET JACKS INSTALLED. EXAMPLE: IF 100 JACK LOCATIONS ARE INSTALLED THEN PROVIDE 10 SPARE JACKS (0.1x100).
9. PROVIDE DEVICE CABLES AND SPARE JACKS FOR EACH DIFFERENT SYSTEM.
10. FIBER-OPTIC CABLES SHALL HAVE A MINIMUM OF TEN FEET OF SLACK ON EACH END.
11. OSP FIBER-OPTIC CABLES SHALL HAVE A MINIMIUM OF TEN FEET OF SLACK ON EACH END.
12. TERMINATE ALL BACKBONE FIBER-OPTIC STRANDS THROUGH USE OF SC-TYPE NO EPOXY/NO
POLISH MECHANICAL SPLICED FIBER-OPTIC CONNECTORS WITH CERAMIC TIP.
13. THE POTS SYSTEM HEADEND AND HANDSETS WILL BE GOVERNMENT FURNISHED AND
GOVERNMENT INSTALLED.
14. ALL NETWORK ELECTRONICS INCLUDING, BUT NOT LIMITED TO CORE SWITCHES, EDGE
SWITCHES, SERVERS, ETC., SHALL BE GOVERNMENT FURNISHED AND GOVERNMENT
INSTALLED.
15. COMMUNICATIONS CONTRACTOR SHALL TERMINATE ALL BACKBONE AND HORIZONTAL CABLING
UNLESS SPECIFICALLY INSTRUCTED OTHERWISE. PROVIDE ALL NECESSARY PATCH PANELS,
PUNCH DOWN BLOCKS, MATERIALS, ETC. FOR A COMPLETE SYSTEM.
16. PATCH CORDS PROVIDED SHALL BE FACTORY MADE; COPPER OR FIBER MATERIAL SHALL BE
RATED TO MATCH FACILITY NETWORK SPECIFICATIONS.
17. ALL PATCH PANELS SHALL MATCH THE CATEGORY CABLING TERMINATED ON THEM AND HAVE
SUFFICIENT PATCH CORDS PROVIDED TO FULLY UTILIZE THE PATCH PANELS.
18. COPPER PATCH CORD SHALL BE: FOUR PAIR, 100-OHM TWISTED PAIR CABLE WITH 24 GAUGE
STRANDED COPPER CONDUCTORS AND MUST MEET THE SPECIFICATIONS TO SUPPORT GIGABIT
ETHERNET AND AT LEAST 500MHZ BANDWIDTH.
19. PROVIDE PATCH CORDS FOR EACH DIFFERENT SYSTEM.
20. FLEXIBLE METAL RACEWAY SYSTEMS ARE NOT PERMITTED FOR CABLE DISTRIBUTION.
21. DEVICE COVER AND FINISH TO BE COORDINATED WITH ARCHITECT.
22. PROVIDE KRONE PATCH CORDS FOR VOICE/POTS.
DC
MS MS
DP
CR
KP
PP
DA
CCTV
KPM
BACKBOX FOR DOOR CONTACT, BMS. LOCATE 2" ABOVE AND 2" TO THE SIDE
OF THE DOOR.
BACKBOX FOR DOOR POSITION SWITCH.
BACKBOX FOR LOCAL DOOR ANNUNCIATOR.
BACKBOX FOR CARD READER, MOUNT 4'-0" AFF UNLESS NOTED OTHERWISE.
BACKBOX FOR KEYPAD. MOUNT 4'-0" AFF UNLESS NOTED OTHERWISE.
BACKBOX FOR ACS SECURITY PIN PAD. MOUNT 4'-0" AFF UNLESS NOTED
OTHERWISE.
BACKBOX FOR PREMISE (IDS/ACS) CONTROL UNIT. KEYPAD OF PREMISE
CONTROL UNIT SHALL BE USED TO MONITOR AND ARM/DISARM ALL MOTION AND
GLASS BREAK SENSING DEVICES WITHIN THE FACILITY. MOUNT 4'-0" AFF
UNLESS NOTED OTHERWISE.
BACKBOX FOR PASSIVE INFRARED OR DUAL TECHNOLOGY MOTION DETECTOR.
SUBSCRIPT INDICATES THAT SENSOR DEVICE CAN BE ARM/DISARM BY KEYPAD
WITH SIMILAR SUBSCRIPT.
S BACKBOX FOR CEILING MOUNTED AV SPEAKER. COORDINATE ROUGH-IN
LOCATIONS WITH AV INSTALLER PRIOR TO ROUGH-IN.
CC BACKBOX FOR WALL CCTV DOME CAMERA.
CCTV SYSTEM EQUIPMENT WORKSTATION WITH - WALL MOUNTED MONITOR.
PROVIDE MOUNTING BRACKETS AND OTHER ENHANCEMENTS REQUIRED TO
SECURELY MOUNT THE EQUIPMENT.
FB OPEN OFFICE NON-SECURE FLUSH-MOUNTED DATA FLOOR BOX FOR CABLE
CONNECTION TO FURNITURE SYSTEM. INSTALLED IN ACCESS FLOOR SPACE.
PROVIDE EACH FLOOR BOX WITH TWELVE CAT6 DATA PORTS UNLESS
SUBSCRIPT INDICATES OTHERWISE. PROVIDE TWO DATA PORTS AT EACH
DESK.
FB OPEN OFFICE SECURE FLUSH-MOUNTED DATA FLOOR BOX FOR CABLE
CONNECTION TO FURNITURE SYSTEM. INSTALLED IN ACCESS FLOOR SPACE.
PROVIDE EACH FLOOR BOX WITH TWELVE CAT6 DATA PORTS UNLESS
SUBSCRIPT INDICATES OTHERWISE. PROVIDE TWO DATA PORTS AT EACH
DESK.
S
KVM FLUSH MOUNTED FLOORBOX WITH KVM AND AUX CONNECTIONS. COORDINATE
QUANTITY OF CONNECTIONS, AND ROUGH-IN LOCATION, WITH AV INSTALLER
PRIOR TO ROUGH-IN. PROVIDE 4-GANG BACKBOX UNLESS SUBSCRIPT INDICATES
OTHERWISE.
RECESSED FLOOR BOX (WITH FLUSH LIDS) CONTAINING 4-GANG BACKBOX
FOR A/V DEVICE CONNECTION. SEE A/V DRAWINGS FOR ADDITIONAL
INFORMATION.
A
WIP WIRELESS INTRUSION PREVENTION SYSTEM SENSOR WITH PoE.
CDS WALL MOUNTED CELLPHONE DETECTION SYSTEM SENSOR WITH PoE AND
INTEGRAL ANTENNA.
18" AFF WALL MOUNTED BACKBOX FOR A/V DEVICE CONNECTION. PROVIDE
2-GANG BACKBOX UNLESS SUBSCRIPT INDICATES OTHERWISE. COORDINATE
QUANTITY OF CONNECTIONS AND ROUGH-IN LOCATIONS WITH AV INSTALLER
PRIOR TO ROUGH-IN.
A
GS BACKBOX FOR DUAL (ACOUSTIC AND SHOCKWAVE) TECHNOLOGY GLASS
BREAK SENSOR. PROVIDE SENSORS RATED FOR THE TYPE OF GLASS USED
THROUGHOUT THE FACILITY. SUBSCRIPT INDICATES THAT SENSOR DEVICE
CAN BE ARM/DISARM KEYPAD WITH LIKEWISE SUBSCRIPT.
COMMUNICATIONS LEGEND - (CONTINUED)
C CEILING MOUNTED NON-SECURE DATA OUTLETS WITH FOUR 8P8C JACKS.
SECURE DATA WITH SIX LC FIBER OPTIC JACKS PER OUTLET MOUNTED AT 18"
AFF.
FO
J
SYSTEM FURNITURE CONNECTION. PROVIDE EACH SYSTEM FURNITURE
CONNECTION WITH TWELVE CAT6 DATA UNLESS NUMERICAL SUBSCRIPT
INDICATES OTHERWISE. PROVIDE TWO DATA PORTS AT EACH DESK. SUBSCRIPT
"S" INDICATES SECURE CABLES.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:5
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET001
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
TE
LE
C O
M M
U N
IC
A
TI
O
N S
L E
G E
N D
, A B
B R
E V
IA
TI
O N
S A
N D
G E
N E
R A
L N
O
TE
S
JAZ
12794419
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
REF REFREFREF
FB FB
FB FBFB FB
FB FBFB FB
FB FBFB FB
KVM
KVM
FB FB
J J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
ET401
C2
S
S
TV
S
TV
TV
TV
TV
TV
TV
S
S A
S
S
S
S
S
A
S
S
S
S
S
S
S
S
S
S
TV
S
S
TV
S
S
S
S
S
S
S
S
WP
48"
S
S S
S
S
S
S
S
S
A 1/
E T
TV TV
TV
TV
WP
TV
TV
TV
TV
8 8 8 8S S
8 8 8 8
8 8 8 8
S S8 8 8 8S S
TV
UPS AND BATTERY
CABINET
48"
A
A
A
A
A
S
S
S
S
S
A
S
S
A
S
S
A
A
A
A
S A
S
S
A
B
C
D
E
F
G
21 3 4 5 6 7 8 9
A A
A
FOR VIDEO
DISPLAY WALL
FOR PROJECTOR
FOR PROJECTOR
SHARED
OFFICE
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
OFFICE 8
OFFICE 9
OPEN
OFFICE
OFFICE 11
OFFICE 10
JTAC
CONTROL
ROOM
CONFERENCE
ROOM
PRINTER
BLUE OPS
AREA
JTAC
COMM
ELECTRICAL
MECHANICAL
SPACE
CORRIDOR
COVERED
AREA
SECURITY
103 SECURITY
BUNK
MENS
RESTROOM
ENTRY
VESTIBULE
WOMENS
RESTROOM
C
C
S
S S
FO
S
CLOSET
A 1/
E T
OUTSIDE
DOOR
48"
S
TV
TV
TV
TV
TV
TV
S
S
S
S
S
S
S
S
S
S
S
S
A S
S
S
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:0
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET101
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
F
IR
S T
F
LO
O R
P
LA
N
T E
LE
C
O M
M U
N
IC
A
TI
O N
S
A R
E A
A
JAZ
12794420
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
TELECOMMUNICATIONS KEYNOTES
KEY PLAN
8'4' 16'0 1/8" = 1'-0" A1
FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA A
A B
PLAN
NORTH
1. PROVIDE SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND NIPRNET
DEVICE OUTSIDE EDGE OF 5"x5" BOX.
2. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND
NIPRNET CABLE PATHWAYS AND TERMINATIONS.
3. IN INDIVIDUAL OFFICES, MOUNT TV OUTLETS AT 66"AFF. IN OPEN OFFICES
MOUNT TV OUTLETS AT 72"AFF. LOCATE TV OUTLET ADJACENT TO THEIR
RESPECTIVE POWER RECEPTACLE.
4. FLOOR BOX TO BE LIMITED TO SERVING A MAXIMUM OF 6 WORK AREAS (ALL
PART OF ONE FURNITURE CLUSTER). PROVIDE EACH DESK AREA WITH TWO
NIPR AND TWO SIPR DATA OUTLETS.
5. MOUNT DATA OUTLETS ADJACENT TO POWER OUTLETS, WITH A SEPARATION
DISTANCE OF 6" BETWEEN THE EDGE OF DATA AND POWER FACEPLATES.
6. IN CONFERENCE ROOMS, FLOOR BOXES TO BE ALIGNED NEAR EDGE OF
TABLES AND WITH TABLE LEGS FOR CABLE MANAGEMENT OF POWER, DATA,
AND A/V DEVICES.
7. PROVIDE 6" LINEAR SEPARATION BETWEEN POWER AND DATA NETWORK
CABLES.
8. PROVIDE 2 PORTS PER SYSTEM FURNITURE AND FLOOR BOXES IN
MULTIPLES OF 4. TERMINATE TWO CABLES IN DESK FURNITURE PER
CLASSIFIED NETWORK.
9. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST
REQUIREMENTS.
1 CEILING MOUNTED OUTLET. MOUNT 3-6 INCHES ABOVE THE CEILING.
2 SURFACE MOUNT ALL TELECOMMUNICATIONS DEVICES WITHIN THIS ROOM.
3 CAT6 CABLE ROUTING SHOWN TO AND FROM FLOOR BOXES WITHIN THIS ROOM
ARE DIAGRAMMATIC. COORDINATE ACTUALLY ROUTING OF CAT6 CABLING
WITHIN FLOOR CABLE PATHWAY SYSTEM IN THE FIELD. REFER TO "WALL TO
ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
R E
F
R E
F R
E F
R E
F
FB FB FB
FB
FB FB FB FB
FB FB FB FB
FB FB FB FB FB
FB
FB
FB
FB
FB
FB FB FB FB FB FB
FB FB FB FB FB
FB FB FB FB FB FB
FB
FB
FB
KVM
KVM
KVM
KVM
FB FB FB FB
FB
FB
FB
FB
TV
TV
S S
A
FO
WP
S
S
S
ASTV
TV
S
S
S
S
TV
S
S
TV S
S
STV
S S
S S
SS
SS
48"
S S
S
S
TV
S S S S
SS
S
S
TV
SS
S
SS
TV
S
S
S
TV
S
A
S
TV S
S
S
TV
S
S
S
TV
S
S
S
TV
S
S
S
TV
S
S
S
TV
S
S
S
WP
S
S
S
S
S S S S S S
S
S
A 1/
E T
TV
TV
TV
TV
TV
S
TV TV
TV TV
TV
TV
TV
TV
TV TV
TV TV
TVTV
S S S
8 S
S8 S S8 8 8 S
TV
S8 S S8 8 S8 S8
S8
8 8 8 8 8 8
S8 S S8 8 8 S 8 S
8 8
S8
S8
A S
C
C
A S
C
C
S
A
A
S
S
A
S
A
A
A
A
SA
AAA A A A
A A
A
A
A
A
A
A
S
A
S
TV
TV
1 1
1 1
A
B
C
D
E
F
8 9 10 11 12 13 14
A
FOR PROJECTOR
FOR PROJECTOR
FOR PROJECTOR
FOR PROJECTOR
AA
A
A
A
A
PURPLE
OPS AREA
OFFICE 6
TEAM
ROOM
FIRE
ALARM
ROOM
TRASH/MANT.
BREAKROOM
CORRIDOR
CONFERENCE
ROOM
OFFICE 5
OFFICE 4
OFFICE 3
OFFICE 2
OFFICE 1
CO OFFICE
GREEN
OPS AREA
OFFICE 1
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
CO OFFICE
PRINTER
OFFICE 8
RECEPTION
TEAM
ROOM
CONFERENCE
ROOM
CONFERENCE
ROOM
BREAKROOM
S
S
A
TV
S
A
48"
S
S
S
FO
A 1/
E T
A
OUTSIDE
DOOR
OUTSIDE
DOOR
S
S S
TV
S
FOR VIDEO
DISPLAY WALL
FOR VIDEO
DISPLAY WALL
48"
3 4
8 8 8
S
S
S S
8 S
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:0
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET102
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
F
IR
S T
F
LO
O R
P
LA
N
T E
LE
C
O M
M U
N
IC
A
TI
O N
S
A R
E A
B
JAZ
12794421
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
TELECOMMUNICATIONS KEYNOTES
KEY PLAN
1/8" = 1'-0" A1
FIRST FLOOR PLAN - TELECOMMUNICATIONS - AREA B
8'4' 16'0
A B
PLAN
NORTH
1. PROVIDE SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND NIPRNET
DEVICE OUTSIDE EDGE OF 5"x5" BOX.
2. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND
NIPRNET CABLE PATHWAYS AND TERMINATIONS.
3. IN INDIVIDUAL OFFICES, MOUNT TV OUTLETS AT 66"AFF. IN OPEN OFFICES
MOUNT TV OUTLETS AT 72"AFF. LOCATE TV OUTLET ADJACENT TO THEIR
RESPECTIVE POWER RECEPTACLE.
4. FLOOR BOX TO BE LIMITED TO SERVING A MAXIMUM OF 6 WORK AREAS (ALL
PART OF ONE FURNITURE CLUSTER). PROVIDE EACH DESK AREA WITH TWO
NIPR AND TWO SIPR DATA OUTLETS.
5. MOUNT DATA OUTLETS ADJACENT TO POWER OUTLETS, WITH A SEPARATION
DISTANCE OF 6" BETWEEN THE EDGE OF DATA AND POWER FACEPLATES.
6. IN CONFERENCE ROOMS, FLOOR BOXES TO BE ALIGNED NEAR EDGE OF
TABLES AND WITH TABLE LEGS FOR CABLE MANAGEMENT OF POWER, DATA,
AND A/V DEVICES.
7. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST
REQUIREMENTS.
1 CEILING MOUNTED OUTLET. MOUNT 3-6 INCHES ABOVE THE CEILING.
2 SURFACE MOUNT ALL TELECOMMUNICATIONS DEVICES WITHIN THIS ROOM.
3 OUTLETS TO BE LOCATED IN THE FIRE ALARM CONTROL PANEL. COORDINATE
DURING INSTALLATION.
4 OUTLETS TO BE LOCATED IN THE BAS PANEL. COORDINATE DURING
INSTALLATION.
5 CAT6 CABLE ROUTING SHOWN TO AND FROM FLOOR BOXES WITHIN THIS ROOM
ARE DIAGRAMMATIC. COORDINATE ACTUALLY ROUTING OF CAT6 CABLING
WITHIN FLOOR CABLE PATHWAY SYSTEM IN THE FIELD. REFER TO "WALL TO
ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
J J
J
J
J
J
J
J
J
J
J
J
J
J
OPEN OFFICE
SHARED OFFICE
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
OFFICE 8
OFFICE 9
OFFICE 11
OFFICE 10
CONFERENCE ROOM
JTAC CONTROL ROOM
JTAC
CORRIDOR
MENS RESTROOM
ENTRY VESTIBULE
COVERED AREA
SECURITY
WOMENS RESTROOM
ELECTRICAL
BLUE OPS AREA
MECHANICAL SPACE
COMM
SECURITY BUNK
A 1/
E T
C2
ET401
BREAKROOM
PRINTER
A
B
C
D
E
F
G
21 3 4 5 6 7 8 9
A 1/
E T
S
1- 1/
4" C
S
S
S
S
S
S
1- 1/
4" C
8 S
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:1
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET105
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
F
IR
S T
F
LO
O R
P
LA
N
N E
TW
O
R K
B E
LO
W
F
LO
O R
R O
U
TI
N G
A
R E
A A
JAZ
12794424
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
NETWORK KEYNOTES
KEY PLAN
8'4' 16'0
1. PROVIDE A MINIMUM SEPARATION OF 12" BETWEEN THE NIPR AND SIPR CABLE
TRAYS.
2. BOND CABLE TRAY TO GROUNDING INFRASTRUCTURE. REFER TO THE RISER
DIAGRAMS ON THE ET600 SERIES SHEETS FOR ADDITIONAL INFORMATION.
3. RUN GROUND WIRE WITH THE CABLE TRAY AND BOND GROUND WIRE TO
EACH SECTION OF THE CABLE TRAY. BOND GROUND WIRE TO THE RAISED
GROUND FLOOR.
4. ROUTE SIPRNET AND NIPRNET PATHWAYS FROM OPPOSITE DIRECTIONS,
CROSSING AT 90 DEGREES BUT NEVER TOUCHING.
5. FOR UNDERFLOOR CABLE PATHWAY SYSTEM, COORDINATE FLOOR
PENETRATIONS AND FLOOR PEDESTAL LOCATIONS WITH OTHER CONTRACTORS
AND MODULAR FURNITURE LAYOUT. PROVIDE ALL FLEXIBLE CONDUIT BOXES
AND MATERIALS AS NECESSARY FOR CONNECTIONS.
6. REFER TO SHEET ET102 FOR LOCATION AND QUANTITY OF DATA DEVICES AND
DATA BOXES.
7. PROVIDE A MINIMUM OF 2" OF FREE SPACE BETWEEN THE TOP OF THE CABLE
TRAY SIDE RAILS AND THE UNDERSIDE OF THE STRINGERS.
8. BOND ALL METAL PARTS OF THE ACCESS FLOOR TO GROUND. FOLLOW THE
ACCESS FLOOR MANUFACTURER'S GUIDELINES AND ALL APPLICABLE CODES.
9. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST
REQUIREMENTS.
10. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND
NIPRNET CABLE PATHWAYS AND TERMINATIONS.
A B
PLAN
NORTH
1 ACCESS PATHWAY FROM CEILING TO BELOW FLOOR CONCEALED IN WALL.
2 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF SECURE
1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT NEAR
NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4" CONDUITS
REQUIRED FOR PATHWAY ACCESS WITHIN WALL CAVITY. NOTE QUANTITY OF
CONDUITS ARE BASED ON A MAXIMUM OF NINE CAT6 CABLES (WITH AN OUTER
DIAMETER OF 0.265) PER CONDUIT, AND 40% CONDUIT FILL. REFER TO "WALL
TO ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.
3 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF NON-SECURE
1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT NEAR
NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4" CONDUITS
REQUIRED FOR PATHWAY ACCESS WITHIN WALL CAVITY. NOTE QUANTITY OF
CONDUITS ARE BASED ON A MAXIMUM OF NINE CAT6 CABLES (WITH AN OUTER
DIAMETER OF 0.265) PER CONDUIT, AND 40% CONDUIT FILL. REFER TO "WALL
TO ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.
1/8" = 1'-0" A1
FIRST FLOOR PLAN - NETWORK BELOW FLOOR ROUTING - AREA A
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
CORRIDOR
FIRE ALARM ROOM
TRASH/MANT.
BREAKROOM
OFFICE 6
TEAM ROOM
PURPLE OPS AREA
GREEN OPS AREA
CONFERENCE ROOM
OFFICE 5
OFFICE 4
OFFICE 3
OFFICE 2
OFFICE 1
CO OFFICE
307 OFFICE 1
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
CO OFFICE
OFFICE 8
TEAM ROOM
BREAKROOM
CONFERENCE ROOM
CONFERENCE ROOM
PRINTER
RECEPTION
CORRIDOR
A 1/
E T
A
B
C
D
E
F
8 9 10 11 12 13 14
A 1/
E T
S
S
S
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:1
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET106
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
F
IR
S T
F
LO
O R
P
LA
N
N E
TW
O
R K
B E
LO
W
F
LO
O R
R O
U
TI
N G
A
R E
A B
JAZ
12794425
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
NETWORK KEYNOTES
KEY PLAN
8'4' 16'0
A B
PLAN
NORTH
1. PROVIDE A MINIMUM SEPARATION OF 12" BETWEEN THE NIPR AND SIPR
CABLE TRAYS.
2. BOND CABLE TRAY TO GROUNDING INFRASTRUCTURE. REFER TO THE RISER
DIAGRAMS ON THE ET600 SERIES SHEETS FOR ADDITIONAL INFORMATION.
3. RUN GROUND WIRE WITH THE CABLE TRAY AND BOND GROUND WIRE TO
EACH SECTION OF THE CABLE TRAY. BOND GROUND WIRE TO THE RAISED
GROUND FLOOR.
4. ROUTE SIPRNET AND NIPRNET PATHWAYS FROM OPPOSITE DIRECTIONS,
CROSSING AT 90 DEGREES BUT NEVER TOUCHING.
5. FOR UNDERFLOOR PATHWAY SYSTEM, COORDINATE FLOOR PENETRATIONS
AND FLOOR PEDESTAL LOCATIONS WITH OTHER CONTRACTORS AND
MODULAR FURNITURE LAYOUT. PROVIDE ALL FLEXIBLE CONDUIT BOXES AND
MATERIALS AS NECESSARY FOR CONNECTIONS.
6. REFER TO SHEET ET102 FOR LOCATION AND QUANTITY OF DATA DEVICES
AND DATA BOXES.
7. PROVIDE A MINIMUM OF 2" OF FREE SPACE BETWEEN THE TOP OF THE CABLE
TRAY SIDE RAILS AND THE UNDERSIDE OF THE STRINGERS.
8. BOND ALL METAL PARTS OF THE ACCESS FLOOR TO GROUND. FOLLOW THE
ACCESS FLOOR MANUFACTURER'S GUIDELINES AND ALL APPLICABLE CODES.
9. ENSURE PROPER PATHWAY SEPARATIONS PER TIA-569 CNSSAM TEMPEST
REQUIREMENTS.
10. PROVIDE MINIMUM SEPARATION DISTANCE OF 6" BETWEEN SIPRNET AND
NIPRNET CABLE PATHWAYS AND TERMINATIONS.
1 ACCESS PATHWAY FROM CEILING TO BELOW FLOOR CONCEALED IN WALL.
2 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF SECURE
1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT NEAR
NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4" CONDUITS
REQUIRED FOR PATHWAY ACCESS WITHIN CAVITY. NOTE THE QUANTITY OF
CONDUITS IS BASED ON A MAXIMUM OF NINE CAT6 CABLES, (WITH AN OUTER
DIAMETER OF 0.265), AND 40% CONDUIT FILL. REFER TO "WALL TO ACCESS
FLOORING TRANSITION" DETAIL FOR ADDITIONAL REQUIREMENTS.
3 HATCHING PROVIDES SUGGESTED LOCATION FOR GROUPING OF NON-
SECURE 1-1/4" CONDUITS FOR CABLE ROUTING. NUMERICAL SUBSCRIPT
NEAR NETWORK KEYNOTE INDICATES ESTIMATED QUANTITY OF 1-1/4"
CONDUITS REQUIRED FOR PATHWAY ACCESS WITHIN WALL CAVITY. NOTE
THE QUANTITY OF CONDUITS IS BASED ON A MAXIMUM OF NINE CAT6 CABLES,
(WITH AN OUTER DIAMETER PF 0.265), AND 40% CONDUIT FILL. REFER TO
"WALL TO ACCESS FLOORING TRANSITION" DETAIL FOR ADDITIONAL
REQUIREMENTS.
1/8" = 1'-0" A1
FIRST FLOOR PLAN - NETWORK BELOW FLOOR ROUTING - AREA B
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
COMM
A1
ET401
SECURITY SYSTEM IDS/ACS
TMGB
PROTECTED ENTRANCE TERMINAL
FOR INCOMING OSP COPPER LINES
TP
NIPR RACK #1
(FRONT)
NIPR RACK #2
(FRONT)
NIPR RACK #3
(FRONT)
SIPR RACK #1
(FRONT)
SIPR RACK #2
(FRONT)
SIPR RACK #3
(FRONT)
48"
4'
TYPICAL - 12" LADDER
RUNWAY
TYPICAL - PLYWOOD
BACKBOARD
TYPICAL - SPACE FOR
EQUIPMENT RACK
C
PROTECTED ENTRANCE TERMINAL
FOR INCOMING OSP COPPER LINES
TMGB
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:3
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET401
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
E N
LA
R
G E
D P
LA
N
S
JAZ
12794426
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
GENERAL NOTES
NETWORK KEYNOTES
1/2" = 1'-0" (ET101)
C2
COMM ROOM 107 - ENLARGED PLAN
PLAN
NORTH
2'1' 4'0
A2
COMM ROOM 107 - ISOMETERIC
NTS
1 HIGH VOLUME CABLE PATHWAYS WITH INTEGRAL FIRESTOPPING AND SOUND
ATTENUATION. BASIS OF DESIGN SHALL BE THE STI EZ PATH SERIES 44+.
2 FOUR 4" CONDUITS ROUTED BELOW GRADE TO EXISTING UTILITY MANHOLE
AT EVERETTE CREEK RD. SEE SHEETS ES101 AND ET601 FOR ADDITIONAL
INFORMATION. FIELD COORDINATE LOCATIONS OF CONDUITS PRIOR TO
INSTALLATION.
3 LOCATION OF KRONE BLOCKS.
4 4" CONDUIT ROUTED UNDERGROUND TO ANTENNA PAD. FIELD COORDINATE
LOCATIONS OF CONDUITS PRIOR TO INSTALLATION.
1/4" = 1'-0" (ET401)
A1
COMM ROOM 107 SECTION - PLAN WEST
0 2' 4' 8'
1. MAINTAIN A MINIMUM OF 12" OF SEPARATION BETWEEN SIPR EQUIPMENT AND
NIPR WIRELINES THAT DIRECTLY LEAVE COMM ROOM 107.
2. MAINTAIN A MINIMUM OF 6" OF SEPARATION BETWEEN SIPR CABLES AND NIPR
CABLES THAT DIRECTLY LEAVE COMM ROOM 107.
3. PRIOR TO ROUGH-IN, COORDINATE MOUNTING HEIGHT AND LOCATION OF
ELECTRICAL DEVICES ONSITE TO AVOID POTENTIAL CONFLICTS WITH TELECOM
PASSIVE INFRASTRUCTURE.
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
1 1/4" CONDUIT WITH (4) 4
PAIR CATEGORY 6 CABLE
UP TO CABLE TRAY
TYPICAL -
DUAL MOLDED MODULAR 8P8C FLAT
JACK SET WITH S310 TERMINATIONS
TO BE PRINTED CIRCUIT BOARD THAT
CAN BE INSTALLED FROM FRONT OR
BACK OF FACEPLATE
TELECOMMUNICATION
OUTLET SINGLE GANG
FACEPLATE WITH (2)
MODULAR OPENINGS
MINIMUM 5" SQUARE,
2-7/8" DEEP DOUBLE GANG
JUNCTION BOX WITH PLASTER
RING FOR CONNECTION OF
SINGLE GANG FACEPLATE
LABEL OUTLET ACCORDING
TO LOCAL STANDARDS
1 1/4" CONDUIT WITH (4) 4
PAIR CATEGORY 6 CABLE
UP TO CABLE TRAY
TYPICAL -
DUAL MOLDED MODULAR 8P8C FLAT
JACK SET WITH S310 TERMINATIONS
TO A PRINTED CIRCUIT BOARD THAT
CAN BE INSTALLED FROM FRONT OR
BACK OF FACEPLATE
TELECOMMUNICATION
OUTLET SINGLE GANG
FACEPLATE WITH (2)
MODULAR OPENINGS
MINIMUM 5" SQUARE,
2-7/8" DEEP DOUBLE GANG
JUNCTION BOX WITH PLASTER
RING FOR CONNECTION OF
SINGLE GANG FACEPLATE
LABEL OUTLET ACCORDING
TO LOCAL STANDARDS
3' -1
0" T
O F
LO
O
R , U
O N
1" CONDUIT WITH
(1) 4 PAIR CATEGORY 6
CABLE TO CABLE TRAY
8P8C VOICE JACK
TELECOMMUNICATION
OUTLET SINGLE GANG
FACEPLATE WITH
SINGLE VOICE OPENING
MINIMUM 2"x4"x2-1/8"
DEEP JUNCTION BOX
WITH SINGLE GANG
EXTENSION
MOUNTING EAR
MOUNTING EAR
VOICE
LABEL OUTLET
ACCORDING TO
LOCAL STANDARDS
NETWORK COLOR MATRIX
NETWORK COLOR JACKET
COLOR
NOTES
NIPRNET GREEN -
SIPRNET RED -
VOICE GREEN FOR TELEPHONE NOT ROUTED THROUGH THE VOIP DATA SWITCH.
1 1/4" CONDUIT UP TO
CABLE TRAY
TYPICAL -
DUPLEX SC
CONNECTORS,
NON-KEYED,
COLOR-CODED
TELECOMMUNICATION
OUTLET SINGLE GANG
FACEPLATE WITH (2)
MODULAR OPENINGS
MINIMUM 5" SQUARE,
2-7/8" DEEP DOUBLE GANG
JUNCTION BOX WITH
PLASTER RING FOR
CONNECTION OF SINGLE
GANG FACEPLATE
LABEL OUTLET
ACCORDINGLY
MODULAR SPACE,
1/2 SIZE SLOPED INSERT
SIDE VIEW ISOMETRIC VIEW
FLOOR OUTLET NOTES:
1. BACKBOX TO BE RATED FOR FLOOR CONSTRUCTION (WOOD, CONCRETE, RAISED FLOOR, ETC.) OF LOCATION WHERE
INSTALLED.
2. FOR BACKBOX LOCATED IN ACCESS FLOORING SYSTEM, COORDINATE BACKBOX AND FACEPLATE WITH ACCESS
FLOORING SYSTEM PRIOR TO INSTALLATION.
3/4" KNOCKOUT
1-PLACE EACH SIDE
1" KNOCKOUT
4-PLACES EACH SIDE
TYPICAL -
DUAL MOLDED MODULAR 8P8C FLAT
JACK SET WITH S310 TERMINATIONS TO A PRINTED
CIRCUIT BOARD THAT CAN BE INSTALLED FROM
FRONT OR BACK OF FACEPLATE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:3
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET501
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
TE
LE
C O
M M
U N
IC
A
T
IO
N S
D E
TA
IL
S
JAZ
12794427
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
NTS
C1
SECURE OUTLET DETAIL (S)
NTS
C2
NON-SECURE OUTLET DETAIL
NTS
A1
SINGLE VOICE (POTS) OUTLET DETAIL
NTS
C3
SECURE DATA OUTLET DETAIL (FO)
JAS
NTS
A2
FLOOR OUTLET - STANDARD TELE/DATA DETAIL
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
PROVIDE BONDING LUG AT
EACH END OF EACH CABLE
TRAY SECTION AND CONNECT
THE CABLE TRAY GROUND
WIRE AT EACH LOCATION
BELL BONDING BUSHING
AT END OF CONDUIT
BEFORE CABLE TRAY.
PROVIDE #6 BONDING WIRE
FROM BUSHING TO CABLE
TRAY GROUND WIRE
CONDUIT WITH DATA, VOICE
OR CATV CABLE(S)
PROVIDE #2 AWG COPPER
GROUND CONDUCTOR
THE ENTIRE LENGTH OF
THE CABLE TRAY. ATTACH
GROUND CONDUCTOR ON
OUTSIDE OF THE CABLE TRAY
PROVIDE PROTECTIVE COATING
OR SLEEVE OVER ALL EXPOSED
THREADS AND SIMILAR SURFACES,
WHEN PROVIDED, FROM TOP OF
TRAY TO 12" ABOVE THE TRAY
PROVIDE BONDING LUG AT EACH
END OF EACH CABLE TRAY SECTION
AND CONNECT THE CABLE TRAY
GROUND WIRE AT EACH LOCATION
PROVIDE SUPPORT CABLES OR
THREADED ROD ON EACH SIDE
OF THE CABLE TRAY, SIZE AND
SPACING, AS RECOMMENDED BY
CABLE TRAY MANUFACTURER
REQUIREMENTS FOR FULL CABLE
TRAY AND SEISMIC REQUIREMENTS
DATA, VOICE AND CATV
CABLES IN CABLE TRAY
SUPPORT HANGERS
CABLE TRAY SYSTEM
CABLE TRAY SYSTEM
DATA, VOICE AND CATV
CABLES IN CABLE TRAY
PROVIDE #2 AWG COPPER
GROUND CONDUCTOR THE
ENTIRE LENGTH OF THE
CABLE TRAY. ATTACH GROUND
CONDUCTOR ON OUTSIDE OF
THE CABLE TRAY
PROVIDE CONTINUOUS BONDING
THROUGHOUT CABLE TRAY SYSTEM
ON THE EXTERIOR OF THE TRAY
USING TRAY CLAMPS. BOND CABLES
AT "T"S AND TRAY SEPARATED BY
ELEVATION
PROVIDE BONDING LUG AT EACH
TRANSITION IN CABLE TRAY SECTION
AND CONNECT THE CABLE TRAY
GROUND WIRE AT EACH LOCATION
TELEPHONE TERMINAL
BOARD
GROUND WIRE
TO EQUIPMENT
1/4" THICK BY 24"
LONG COPPER
GROUND BUS
STAND-OFF INSULATOR
MOUNTED TO WALL
GROUND WIRE
TO EQUIPMENT
CABLE TRAY ABOVE ADJACENT
CEILINGS AND CORRIDORS.
SEE PLANS FOR SIZES AND
ROUTING INFORMATION
WALL PHONE
FLOOR
CEILING
W A
LL
CCTV,
OUTLET MOUNT
PROVIDE CABLE IN CONDUIT
FOR EACH OUTLET
LOCATION TO CABLE TRAY
UNDERFLOOR CABLE TRAY. SEE PLANS
FOR SIZE AND ROUTING INFORMATION
MOUNTED IN RECESSED FLOOR BOX.
DATA OUTLET TO BE MOUNTED
PERPENDICULAR OR AT AN ANGLE TO
PROTECT JACK AND CABLE
CONNECTIONS. DATA OUTLET
MOUNT ADJACENT TO POWER OUTLET
DATA AND VOICE OUTLET.
MOUNT TO MATCH ADJACENT
POWER OUTLET
FINISHED FLOOR
9"
#6 AWG MINIMUM GROUND
WIRE TO METAL CONDUITS
IN ROOM
GROUND WIRE TO EXPOSED
BUILDING COLUMN IN ROOM
IF PRESENT
#4 AWG MINIMUM GROUND
WIRE TO PANELBOARD
ENCLOSURE IN ROOM
#2 AWG MINIMUM GROUND
WIRE TO LADDER RUNWAY(S)
IN ROOM
STAND-OFF INSULATOR MOUNTED
TO WALL. TYPICAL FOR TWO
LOCATIONS
#4 AWG MINIMUM GROUND
WIRE TO PROTECTIVE
ENTRANCE TERMINALS IN
ROOM IF PRESENT
COPPER TMGB SIZE:
4" HIGH BY 1/4" THICK
BY 24" LONG MINIMUM
#2/0 AWG MINIMUM GROUND
WIRE TO BUILDING MAIN
ELECTRICAL SERVICE
#6 AWG MINIMUM
GROUND WIRE TO
UNDERGROUND
CONDUIT STUB-UPS
#6 AWG MINIMUM
GROUND WIRE TO
BUILDING OUTSIDE
PLANT CONDUITS
PROVIDE TWO HOLE BOLTED CONNECTORS
WITH GROUND RATED BELLEVILLE WASHERS
BETWEEN BUS AND CONDUCTOR. PROVIDE
CONDUCTOR GREASE BETWEEN BUS AND
CONNECTIONS. PROVIDE FULL WRAP STRAP
CONNECTORS. CLAMPING OF THE STRAPS
SHALL BE WITH FULL SURFACE CLAMPING
TOOL TO INSURE EVEN COMPRESSION
AROUND THE CABLE
TMGB GENERAL NOTE:
1. PROVIDE GROUNDING IN ACCORDANCE WITH TIA 607.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:3
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET502
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
TE
LE
C O
M M
U N
IC
A
T
IO
N S
D E
TA
IL
S
JAZ
12794428
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
NTS
C1
TYPICAL CABLE TRAY MOUNTING AND BONDING DETAIL
NTS
C4
TYPICAL TMGB SIDE VIEW DETAIL
NTS
A1
TYPICAL OUTLET RISER MOUNTING DETAIL
NTS
A3
TELECOMMUNICATION MAIN GROUND BAR (TMGB) DETAIL
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
FIRE RATED WALL
BEING PENETRATED
CABLE TRAY
FIRE RATED RECTANGULAR
THROUGH-WALL CABLE WAY.
SIMILAR TO SPECIFIED
TECHNOLOGY INC. (STI) SERIES
44 AS REQUIRED FOR EACH
PENETRATION
PROVIDE BONDING LUG AT EACH
END OF EACH CABLE TRAY SECTION
AND CONNECT THE CABLE TRAY
GROUND WIRE AT EACH LOCATION
PROVIDE SUPPORT CABLES OR
THREADED ROD ON EACH SIDE
OF THE CABLE TRAY, SIZE AND
SPACING, AS RECOMMENDED BY
CABLE TRAY MANUFACTURER
REQUIREMENTS FOR FULL CABLE TRAY
CABLE TRAY
1 1/4" CONDUIT UP TO
CABLE TRAY
TYPICAL -
DUAL MOLDED MODULAR 8P8C FLAT
JACK SET WITH S310 TERMINATIONS
TO A PRINTED CIRCUIT BOARD THAT
CAN BE INSTALLED FROM FRONT OR
BACK OF FACEPLATE
TELECOMMUNICATION
OUTLET SINGLE GANG
FACEPLATE WITH (2)
MODULAR OPENINGS
MINIMUM 5" SQUARE,
2-7/8" DEEP DOUBLE GANG
JUNCTION BOX WITH PLASTER
RING FOR CONNECTION OF
SINGLE GANG FACEPLATE
LABEL OUTLET ACCORDING
TO LOCAL STANDARDS
USE HOOK AND LOOP STRIPS TO
SECURE CABLES TO RUNWAY
VERTICAL WALL BRACKET
RUNWAY FOOT KIT
BONDING BUSHING
FLOOR SLAB
EQUIPMENT BONDING
CABLE
CONNECTOR
CONDUIT SLEEVES OR
CONDUITS THRU FLOOR SLAB.
NUMBER OF CONDUIT PER
RISER DIAGRAM
TELECOMMUNICATIONS CABLES
PER RISER DIAGRAM
CABLE RUNWAY
1 1/2" METAL FRAMING
CHANNEL ANCHORED
TO WALL 4/0" O.C.
WALL
SECURELY ANCHOR RUNWAY
FOOT TO FLOOR
NOTES THIS DETAIL:
1. FIRE STOP ALL PENETRATIONS PER SPECIFICATIONS.
2. CABLE RUNWAY TO BE INSTALLED FROM FLOOR TO CEILING.
VERTICAL RUNWAY
SPLICE KIT
CABLE RUNWAY
RUNWAY BEND/
SWIVEL END SPLICE
CABLE RADIUS DROP TO
MAINTAIN PROPER BEND
RADIUS OF CABLES
RUNWAY SIDE MOUNTINGCABLE RADIUS DROP
NOTES THIS DETAIL:
1. ALL CONNECTIONS HARDWARE, PARTS AND PIECES TO BE OF THE SAME MANUFACTURER AS THE CABLE RUNWAY AND APPROVED BY THE MANUFACTURER AS APPROPRIATE FOR THE APPLICATION.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
DRAWFORM REVISION: 17 APRIL 2018
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A
T L A
N T
IC
C
A M
P L
E J E
U N
E
J A
C K
S O
N V
IL
L E
N
C
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
I E
D
440 S. CHURCH STREET, SUITE 1000
CHARLOTTE, NC 28202
TEL (704)338-6700
/6
/2
:4
:3
P M
C rv t\
\1
-E
-C E
N T
R A
L P
-1
M A
R
IN
E H
Q je re m y .f o rr e s t.
rv t
ET503
P
M
A R
IN
E
R A
ID
E
R H
E A
D Q
U A
R T
E R
S
TE
LE
C O
M M
U N
IC
A
T
IO
N S
D E
TA
IL
S
JAZ
12794429
EC DJF
06/19/2020
Approved by Emily Sylvester, Director of Installation Development Division
SGL/RMS
1603164
JA
C
K S
O N
V
IL
LE
, N
O R
T H
C A
R O
LI
N
A M
A R
S O
C
EJA
M
ID
L A
N T
C I C
O R
E
NTS
C1
TYPICAL CABLE TRAY WALL PENETRATION DETAIL
NTS
C3
IPTV/DDC/FACP/WAP OUTLET DETAIL
NTS
A1
CABLE - TELECOMMUNICATIONS ROOM VERTICAL RUNWAY MOUNTING DETAIL
NTS
A3
TYPICAL TELECOMMUNICATION ROOM RUNWAY CONNECTIONS DETAIL
JAS
S Y
M D
E S
C R
IP
T
IO
N
D A
TE
A
P P
R
R
E V
IS
IO
N
/0
5/
PROVIDE 1 1/2" AV CONDUIT TO
NEAREST NIPR CABLE TRAY
PROVIDE 1 1/4" DATA CONDUIT TO
THEIR NEAREST RESPECTIVE
NIPR/SIPR CABLE TRAY
AVNIPR
DATA
SEE AV PLANS FOR
MOUNTING HEIGHT
TYPICAL -
COMMUNICATION CONDUITS SHALL HAVE NO
MORE THAN A MAXIMUM OF TWO 90 DEGREE
BENDS. PROVIDE A PULL STRING FOR ALL
EMPTY CONDUITS.
SIPR
DATA
AV…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .