B-101.pdf

PDF 7 MB Posted

Attached to
P1395 SOF MARINE RAIDER REGIMENT HQ, MCAS, CAMP LEJEUNE
Solicitation number
N40085-19-R-9148
Issued by

About this file

This document contains geotechnical boring logs and a federal contract solicitation for construction services. The solicitation is for the construction of new Marine Raider Regiment headquarters facilities at Marine Corps Air Station Camp Lejeune in North Carolina. The facilities will consist of approximately 30,000 square feet of single-story steel frame buildings, with supporting structures, utilities, parking, roadways, and site work. Special construction features include soil surcharge loads and stormwater management practices. Mechanical, electrical, and communications systems will be installed. Sustainability and force protection standards will be met. The contract award is valued at an estimated $30 million. The solicitation closing date is not provided. The Naval Facilities Engineering Command is the contracting agency.

View the file

Other files

File Type Posted
C-514.pdf PDF
CG103.pdf PDF
CE106.pdf PDF
C-513.pdf PDF
CG107.pdf PDF
CD04-20201022 GER P1395 Marine Raider Bn HQS R4 -ALZ Sealed.pdf PDF
CG108.pdf PDF
REVISION 001.pdf PDF
B-104.pdf PDF
C-507.pdf PDF
B-103.pdf PDF
B-102.pdf PDF
CE103.pdf PDF
C-515.pdf PDF
CE102.pdf PDF
AMENDMAENT 0004 FOR P1395.pdf PDF
01 30 01.00 22.pdf PDF
P1395 08052020 Arch Revisions.pdf PDF
20_0622_P1395_Marine-Raider_HQ_FInal_Interior_Sheets.pdf PDF
P-1395-E-Revision 1_2020-08-05.pdf PDF
P1395 AMENDMENT 0003.pdf PDF
P1395 MARINE RAIDER FF-E Est Cost Summary_FINAL_20_0810.pdf PDF
09 69 13.pdf PDF
Part 1-P1395 BVD Request for Pricing Bid Form Spreadsheet.pdf PDF
UPDATED P1395 BID SCHEDULE.pdf PDF
P1395 PPI LOG 03.pdf PDF
AMENDMENT 0002 FOR P1395.pdf PDF
PPI LOG 02 Document..pdf PDF
P1395 SOF PPIs LOG 01.pdf PDF
10 51 00.pdf PDF
13 42 75.pdf PDF
AMENDMENT 0001 P1395.pdf PDF
1603164spc01of01.pdf PDF
Attachment E - Past Performance Questionnaire.docx DOCX document
Attachment F - Small Business Subcontracting Plan.docx DOCX document
1603164dwg01of03.pdf PDF
ATTACHMENT G P1395 PRICE PROPOSAL FORM.pdf PDF
1603164dwg03of03.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
Attachment D - Small Business Participation and Commitment Strategy.docx DOCX document
1603164dwg02of03.pdf PDF
P1395 RFP for N40085-19-R-9148.pdf PDF
Attachment A - Pre-Proposal Inquiries Form.xlsx XLSX spreadsheet
Attachment C - Small Business Subcontracting Record.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N O

R T H

CARO

L

I N A

P R

O

FE

SS I O

N

E

N G I N E

E

R

050964

SEAL

L A

A A

R O

N L . ZD

IN

A K

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

B-101

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

B O

R

IN

G L

E G

E N

D A

N D

L O

G S

AZ

12794228

SB SD

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

BORING LOG GENERAL NOTES:

1. THE SOIL BORING RECORDS REPRESENT THE GEOTECHNICAL

ENGINEER'S INTERPRETATION OF THE SUBSURFACE

CONDITIONS ENCOUNTERED AT THE SPECIFIC BORING

LOCATIONS AT THE TIME OF THE SITE EXPLORATION BASED ON

VISUAL EXAMINATION OF FIELD SAMPLES OBTAINED AND

LABORATORY CLASSIFICATION TESTING ON SELECTED SAMPLES.

2. LINES DESIGNATING THE INTERFACE BETWEEN VARIOUS STRATA

ON THE BORING RECORDS REPRESENT THE APPROXIMATE

INTERFACE LOCATION. THE ACTUAL TRANSITION BETWEEN

STRATA MAY BE MORE GRADUAL THAN INDICATED. THE BORING

RECORDS MAY NOT NECESSARILY BE REPRESENTATIVE OF THE

MATERIAL CHARACTER AND STRATA THICKNESS OVER THE

ENTIRE CONSTRUCTION AREA.

3. WATER LEVELS SHOWN ON THE BORING RECORDS REPRESENT

THE CONDITIONS ENCOUNTERED AT THE TIME OF THE FIELD

EXPLORATION AND DO NOT NECESSARILY REPRESENT

GROUNDWATER LEVELS THAT WILL BE ENCOUNTERED DURING

CONSTRUCTION. IT IS POSSIBLE THAT GROUNDWATER LEVELS

WILL FLUCTUATE DUE TO SEASONAL VARIATIONS AND OTHER

FACTORS.

4. APPROXIMATE BORING LOCATIONS ARE SHOWN ON DRAWING

SHEET B-100. BORING LOCATIONS (LAT/LONG) WERE

ESTABLISHED USING A HANDHELD GPS RECEIVER HAVING AN

ACCURACY OF 10 FEET. BORING SURFACE ELEVATIONS SHALL BE

CONSIDERED ACCURATE TO NO MORE THAN 0.5 FEET.

5. BORINGS WERE ADVANCED USING MUD ROTARY DRILLING

METHOD AS NOTED. REFER TO THE BORING LOG LEGEND FOR

AN EXPLANATION OF THE SYMBOLS USED. BORINGS AND

TESTING WERE PERFORMED BY GET SOLUTIONS, INC.

FAD

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

N

C D

E Q

C O

M P

LI

A

N C

E

/2 9/

A

LZ

10-29-2020