B-104.pdf

PDF 3 MB Posted

Attached to
P1395 SOF MARINE RAIDER REGIMENT HQ, MCAS, CAMP LEJEUNE
Solicitation number
N40085-19-R-9148
Issued by

About this file

This document contains boring logs and laboratory test results from geotechnical investigations for the P1395 SOF Marine Raider Regiment HQ project at MCAS Camp Lejeune. The project constructs 2,788 square meters of headquarters facilities including single-story steel frame buildings with brick veneer, standing seam metal roofs, and translucent wall panels. Special construction features include soil surcharge loads and stormwater best management practices. Mechanical, electrical, plumbing, and information systems will be installed. Site work includes utilities, parking, fencing, lighting, and stormwater management features. Low impact development and antiterrorism/force protection standards will be followed per federal requirements. The laboratory test results provided represent subsurface soil properties at boring locations and depths for use in design and construction.

View the file

Other files

File Type Posted
C-514.pdf PDF
CG103.pdf PDF
CE106.pdf PDF
C-513.pdf PDF
CG107.pdf PDF
CD04-20201022 GER P1395 Marine Raider Bn HQS R4 -ALZ Sealed.pdf PDF
CG108.pdf PDF
REVISION 001.pdf PDF
C-507.pdf PDF
B-103.pdf PDF
B-102.pdf PDF
CE103.pdf PDF
B-101.pdf PDF
C-515.pdf PDF
CE102.pdf PDF
AMENDMAENT 0004 FOR P1395.pdf PDF
01 30 01.00 22.pdf PDF
P1395 08052020 Arch Revisions.pdf PDF
20_0622_P1395_Marine-Raider_HQ_FInal_Interior_Sheets.pdf PDF
P-1395-E-Revision 1_2020-08-05.pdf PDF
P1395 AMENDMENT 0003.pdf PDF
P1395 MARINE RAIDER FF-E Est Cost Summary_FINAL_20_0810.pdf PDF
09 69 13.pdf PDF
Part 1-P1395 BVD Request for Pricing Bid Form Spreadsheet.pdf PDF
UPDATED P1395 BID SCHEDULE.pdf PDF
P1395 PPI LOG 03.pdf PDF
AMENDMENT 0002 FOR P1395.pdf PDF
PPI LOG 02 Document..pdf PDF
P1395 SOF PPIs LOG 01.pdf PDF
10 51 00.pdf PDF
13 42 75.pdf PDF
AMENDMENT 0001 P1395.pdf PDF
1603164spc01of01.pdf PDF
Attachment E - Past Performance Questionnaire.docx DOCX document
Attachment F - Small Business Subcontracting Plan.docx DOCX document
1603164dwg01of03.pdf PDF
ATTACHMENT G P1395 PRICE PROPOSAL FORM.pdf PDF
1603164dwg03of03.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
Attachment D - Small Business Participation and Commitment Strategy.docx DOCX document
1603164dwg02of03.pdf PDF
P1395 RFP for N40085-19-R-9148.pdf PDF
Attachment A - Pre-Proposal Inquiries Form.xlsx XLSX spreadsheet
Attachment C - Small Business Subcontracting Record.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N O

R T H

CARO

L

I N A

P R

O

FE

SS I O

N

E

N G I N E

E

R

050964

SEAL

L A

A A

R O

N L . ZD

IN

A K

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

B-104

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

B O

R

IN

G L

O G

S A

N D

L A

B O

R A

TO

R

Y T

E S

T R

E S

U

LT

S

AZ

12794231

SB SD

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C I C

O R

E

LABORATORY TESTING NOTES:

1. THE LABORATORY TEST RESULTS REPRESENT THE SUBSURFACE SOIL PROPERTIES

ENCOUNTERED AT THE SPECIFIC BORING LOCATIONS AND DEPTHS. IT IS POSSIBLE THAT

SOIL PROPERTIES AND CONDITIONS BETWEEN THE INDIVIDUAL BORING LOCATIONS AND

DEPTHS WILL BE DIFFERENT FROM THOSE INDICATED.

2. LABORATORY TESTS WERE PERFORMED IN GENERAL ACCORDANCE WITH THE FOLLOWING

ASTM STANDARDS: D2216, D1140, D6913, D7928, D4318, D698, D1883, AND D2435.

3. MOISTURE CONTENT AND INDEX TESTS WERE PERFORMED ON JAR SAMPLES OBTAINED

FROM THE SOIL BORINGS. MOISTURE-DENSITY AND CBR TESTS WERE PERFORMED ON

SURFACE EXCAVATED COMPOSITE BULK SAMPLES.

4. "HDR GEOTECHNCICAL ENGINEERING REPORT, REV. 4 - P-1395 SPECIAL OPERATIONS

FORCES MARINE RAIDER REGIMENTAL HQS" DATED OCTOBER 22, 2020 CONTAINS DETAILS

OF LABORATORY TESTING RESULTS.

FAD

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

N

C D

E Q

C O

M P

LI

A

N C

E

/2 9/

A

LZ

10-29-2020

File details come from the government source that posted it. Updated .