20_0622_P1395_Marine-Raider_HQ_FInal_Interior_Sheets.pdf

PDF 4 MB Posted

Attached to
P1395 SOF MARINE RAIDER REGIMENT HQ, MCAS, CAMP LEJEUNE
Solicitation number
N40085-19-R-9148
Issued by

About this file

This solicitation seeks proposals for the construction of Marine Raider Regiment headquarters facilities at Camp Lejeune, North Carolina. Key details include the construction of approximately 30,000 square feet of single-story steel frame buildings with brick veneer, standing seam metal roofs, and translucent wall panels. The project scope encompasses miscellaneous supporting structures, utilities, parking, roadways, sidewalks, running trails, and site work. Special construction features involve soil surcharge loads and storm water best management practices. Mechanical, electrical, plumbing, and information systems will be designed and installed to support the facilities. Sustainability and force protection measures are required. The closing date for proposals was not specified. The Naval Facilities Engineering Command is the contracting agency.

View the file

Other files

File Type Posted
C-514.pdf PDF
CG103.pdf PDF
CE106.pdf PDF
C-513.pdf PDF
CG107.pdf PDF
CD04-20201022 GER P1395 Marine Raider Bn HQS R4 -ALZ Sealed.pdf PDF
CG108.pdf PDF
REVISION 001.pdf PDF
B-104.pdf PDF
C-507.pdf PDF
B-103.pdf PDF
B-102.pdf PDF
CE103.pdf PDF
B-101.pdf PDF
C-515.pdf PDF
CE102.pdf PDF
AMENDMAENT 0004 FOR P1395.pdf PDF
01 30 01.00 22.pdf PDF
P1395 08052020 Arch Revisions.pdf PDF
P-1395-E-Revision 1_2020-08-05.pdf PDF
P1395 AMENDMENT 0003.pdf PDF
P1395 MARINE RAIDER FF-E Est Cost Summary_FINAL_20_0810.pdf PDF
09 69 13.pdf PDF
Part 1-P1395 BVD Request for Pricing Bid Form Spreadsheet.pdf PDF
UPDATED P1395 BID SCHEDULE.pdf PDF
P1395 PPI LOG 03.pdf PDF
AMENDMENT 0002 FOR P1395.pdf PDF
PPI LOG 02 Document..pdf PDF
P1395 SOF PPIs LOG 01.pdf PDF
10 51 00.pdf PDF
13 42 75.pdf PDF
AMENDMENT 0001 P1395.pdf PDF
1603164spc01of01.pdf PDF
Attachment E - Past Performance Questionnaire.docx DOCX document
Attachment F - Small Business Subcontracting Plan.docx DOCX document
1603164dwg01of03.pdf PDF
ATTACHMENT G P1395 PRICE PROPOSAL FORM.pdf PDF
1603164dwg03of03.pdf PDF
Attachment B - Construction Experience Project Data Sheet.docx DOCX document
Attachment D - Small Business Participation and Commitment Strategy.docx DOCX document
1603164dwg02of03.pdf PDF
P1395 RFP for N40085-19-R-9148.pdf PDF
Attachment A - Pre-Proposal Inquiries Form.xlsx XLSX spreadsheet
Attachment C - Small Business Subcontracting Record.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

I-

A

I-

A

I-

A

I-

1 1

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

RAISED ACCESS FLOORING. SEE SHEETS I-621 AND I-622

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

C A

M P

L E

J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/5

/2

:3

:3

P M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

S

N U

T T

A L L

.r v t

I-605

P M A R

IN

E R A

ID

E R H E A D Q U A R T E R S

O V E R A

LL

F F E P

LA

N

ZNK

12794333

AVS KLC

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C O

R E

C I

SCALE: 1/16" = 1'-0" (A-100)

A1

OVERALL FF&E PLAN

8' 16' 32'0'

KEY PLAN

A B

PLAN

NORTH

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

DJD

OFFICE 9

OFFICE 8

OFFICE 7

OFFICE 6

OFFICE 5

OFFICE 4

OFFICE 3

OFFICE 2

SHARED OFFICE

OPEN OFFICE

OFFICE 11

OFFICE 10

CONFERENCE ROOM

BLUE OPS AREA

MECHANICAL SPACE

ELECTRICAL

COMM

JTAC

CORRIDOR

MENS RESTROOM

WOMENS RESTROOM

SECURITY

SECURITY BUNK

C2

D3

WSC1 C1

QTY 60QTY 60

THIS IS THE

TYPICAL LAYOUT

FOR A PRIVATE

OFFICE, UNO

A11SC1

A15

A11

SC1

QTY 2PRINTER

PRINTER

QTY 28

QTY 28

WR1

QTY 60

FC1

QTY 60

A5

QTY 60

QTY 10

QTY 7

A5

QTY 14

A5

QTY 2

A12

QTY 2

A12

ART1A

A12

A12

A13

A15

BD2

A7

A8

A12

A12

A4

QTY 2

A4

QTY 4

ART1

QTY 2

QTY 2

A

I-

A

I-

ENTRY VESTIBULE

SH3

SH2

SH3

SH2

A11

A14

REF1

A12 A11

REF1

A14

REF1

FB1

REF1

T2

C1

D1C1

FC2

C1

ART3

A11

'-9

C

LR

4' -6

'-9

C

LR

4' -6

'-9

C

LR

4' -6

'-9

4' -6

'-9

C

LR

4' -6

'-9

C

LR

5' -6

I5

C5

WS1WS2WS3WS5 WS4

WS10WS9WS8WS6 WS7

WS11WS12WS13WS15 WS14

WS20WS19WS18WS16 WS17

WS21WS22WS23WS25 WS24

WS30WS29WS28WS26 WS27

WS31WS32WS33WS35 WS34

WS40WS39WS38WS36 WS37

WS41WS42WS43WS45 WS44

WS50WS49WS48WS46 WS47

WS51WS52WS53WS55 WS54

WS60WS59WS58WS56 WS57

C3

C4

SEE ROOM

502 FOR

FURNITURE

LAYOUT

MW1

MW1

T2

QTY 4

A9

A10

A15

EQ EQ

A12A12

D1

C1

FB1

WR2

C3

QTY 2

A15

I6

CLOSET

JTAC CONTROL ROOM

A5

BD1

A15

A6

QTY 4

QTY 4

A5

QTY 2

T1

C1

QTY 2

FC2

A15

QTY 2

PRINTER

BREAKROOM

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

RAISED ACCESS FLOORING. SEE SHEETS I-621 AND I-622

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

C A

M P

L E

J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/5

/2

:3

:3

P M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

S

N U

T T

A L L

.r v t

I-606

P M A R

IN

E R A

ID

E R H E A D Q U A R T E R S

F F E P

LA

N A R E A A

ZNK

12794334

AVS KLC

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C O

R E

C I

SCALE: 1/8" = 1'-0" (A-100)

A1

FF&E PLAN - AREA A

4' 8' 16'0'

KEY PLAN

A B

NEW WORK KEYNOTES

PLAN

NORTH

I5 AV CABINET. SEE AV DRAWINGS AND SPECS

I6 TELEVISION, SEE AV DRAWINGS AND SPECS

FURNISHING AND EQUIPMENT LEGEND

WSC1 WORKSTATION - 6' x 8'

WR2 WARDROBE - 30"W - OFFICES

WR1 WARDROBE - 24"W - METAL (AT WSC1)

T3 TABLE, SMALL CONFERENCE

T2 DESK, 30"W x 60"L - CONFERENCE ROOMS

T1 DESK, 30" x 72"L - OPS AREAS

SH3 HIGH SECURITY PAPER SHREDDER

SH2 HIGH SECURITY DVD & CD SHREDDER

SH1 CROSS CUT AND CD SHREDDER

SC1 STORAGE CABINET - 36"W

REF1 REFRIGERATOR - COFFEE AREAS

MW1 COMMERCIAL MICROWAVE

FC2 FILE CABINET - 36"W x 4H, LATERAL - METAL

FC1 MOBILE BF PED W/ATTACHED SEAT CUSHION (PART OF WSC1)

FB1 FILE/ BOOKCASE - 30"W - METAL/LAMINATE TOP

D3 DESK - COMMAND U-SHAPED INCLUDING WARDROBE

D2 U-SHAPED DESK - RECEPTION - LAMINATE

D1 DESK W/SIDE HUTCH - 6' x 6'-6" - LAMINATED METAL

CL2 (3) LOUNGE CHAIRS W/ (2) TABLES

C5 CHAIR - CONFERENCE

C4 CHAIR - GUEST - EXECUTIVE OFFICE

C3 CHAIR - GUEST - PRIVATE OFFICE AND CONFERENCE

C2 CHAIR - TASK - EXECUTIVE OFFICE

C1 CHAIR - TASK - CARPET CASTERS

BD2 NIGHT STAND

BD1 BUNK BED

ART3 CHAIN OF COMMAND

ART1A LOGO/GRAPHICS

ART1 LOGO/GRAPHICS

A15 WALL CLOCK

A14 PLUMBED COFFEE - 2 BURNER

A13 TRASH AT LOBBY

A12 TRASH CAN

A11 RECYCLE BIN AT BREAKROOMS AND PRINT ROOMS

A10 DEFIBRILLATOR - PORTABLE

A9 TABLE LAMP AT NIGHTSTAND

A8 BED IN A BAG

A7 MATTRESS - TWIN

A6 TIME ZONAL CLOCK

A5 TRASH CAN - DESK SIDE

A4 SHOWER CURTAIN (SPA CURTAIN)

A3 JANITOR SUPPLY CART

A2 TILT TRUCK - TRASH

MARK NAME

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

PURPLE OPS AREA

CO OFFICE

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

CONFERENCE ROOM

CORRIDOR

OFFICE 6

TRASH/MANT.

BREAKROOM

CORRIDOR

FIRE ALARM ROOM

CONFERENCE ROOM

BREAKROOM

CONFERENCE ROOM

TEAM ROOM

OFFICE 8

PRINTER

CO OFFICE

OFFICE 7

OFFICE 6

OFFICE 5

OFFICE 3

OFFICE 2

OFFICE 1

GREEN OPS AREA

C1

WR2

FB1

QTY 2

TEAM ROOM

C2

QTY 4QTY 14

QTY 8

SC1

QTY 3

PRINTER

PRINTER

PRINTER

SC1

QTY 2

SC1

QTY 3

SC1

QTY 2

A12

A11

QTY 3

A5

QTY 18

QTY 35

QTY 35

D1

D2

C1

CL2

ART1A

ART1AART1A

SH1

SH2

SH3

A11

A5

QTY 2

A12

A11

A5

QTY 30

QTY 59

QTY 59

SH3

SH2

SH1

A11

QTY 2

A11

A12

QTY 6

A2

QTY 2

A3

REF1

QTY 5

A6

A5

QTY 2

A6A14

MW1

A14

REF1

REF1

A11

FB1

D3

C2

A

I-

A

I-

D3

FB1

QTY 2

C1

T1

C1

T2

T2

MW1

QTY 12

C5

QTY 6

QTY 4

A5

QTY 2

T2

QTY 10

C5

C3

C5

QTY 6

T2

REF1

C

LR

'-9

/4

C

LR

9' -9

6'-6" 6'-6" 6'-6"

8'-0" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8"

THIS IS THE TYPICAL

LAYOUT FOR A SMALLER

PRIVATE OFFICE. SEE

RM 511 FOR TYP

D1

C1

WR2

QTY 2

T3

I5I5

I5

SEE OFFICE 213

LAYOUT

SEE OFFICE 213

LAYOUT

SEE OFFICE 213

LAYOUT

SEE OFFICE 213

LAYOUT

OFFICE 4

SEE OFFICE 213

LAYOUT

C3

C3

C3

C4

C4

MW1

A10A12

A15

MW1

A6

A6

A6

A5

A5

QTY 2

QTY 4 QTY 4

T1

QTY 2

T1

QTY 2

C1

C1

A15

A15

A15

A15

C3

A15

A15

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

RAISED ACCESS FLOORING. SEE SHEETS I-621 AND I-622

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

C A

M P

L E

J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/5

/2

:3

:4

P M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

S

N U

T T

A L L

.r v t

I-607

P M A R

IN

E R A

ID

E R H E A D Q U A R T E R S

F F E P

LA

N A R E A B

ZNK

12794335

AVS KLC

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C O

R E

C I

SCALE: 1/8" = 1'-0" (A-100)

A1

FF&E PLAN - AREA B

4' 8' 16'0'

KEY PLAN

A B

NEW WORK KEYNOTES

PLAN

NORTH

I5 AV CABINET. SEE AV DRAWINGS AND SPECS

FURNISHING AND EQUIPMENT LEGEND

WSC1 WORKSTATION - 6' x 8'

WR2 WARDROBE - 30"W - OFFICES

WR1 WARDROBE - 24"W - METAL (AT WSC1)

T3 TABLE, SMALL CONFERENCE

T2 DESK, 30"W x 60"L - CONFERENCE ROOMS

T1 DESK, 30" x 72"L - OPS AREAS

SH3 HIGH SECURITY PAPER SHREDDER

SH2 HIGH SECURITY DVD & CD SHREDDER

SH1 CROSS CUT AND CD SHREDDER

SC1 STORAGE CABINET - 36"W

REF1 REFRIGERATOR - COFFEE AREAS

MW1 COMMERCIAL MICROWAVE

FC2 FILE CABINET - 36"W x 4H, LATERAL - METAL

FC1 MOBILE BF PED W/ATTACHED SEAT CUSHION (PART OF WSC1)

FB1 FILE/ BOOKCASE - 30"W - METAL/LAMINATE TOP

D3 DESK - COMMAND U-SHAPED INCLUDING WARDROBE

D2 U-SHAPED DESK - RECEPTION - LAMINATE

D1 DESK W/SIDE HUTCH - 6' x 6'-6" - LAMINATED METAL

CL2 (3) LOUNGE CHAIRS W/ (2) TABLES

C5 CHAIR - CONFERENCE

C4 CHAIR - GUEST - EXECUTIVE OFFICE

C3 CHAIR - GUEST - PRIVATE OFFICE AND CONFERENCE

C2 CHAIR - TASK - EXECUTIVE OFFICE

C1 CHAIR - TASK - CARPET CASTERS

BD2 NIGHT STAND

BD1 BUNK BED

ART3 CHAIN OF COMMAND

ART1A LOGO/GRAPHICS

ART1 LOGO/GRAPHICS

A15 WALL CLOCK

A14 PLUMBED COFFEE - 2 BURNER

A13 TRASH AT LOBBY

A12 TRASH CAN

A11 RECYCLE BIN AT BREAKROOMS AND PRINT ROOMS

A10 DEFIBRILLATOR - PORTABLE

A9 TABLE LAMP AT NIGHTSTAND

A8 BED IN A BAG

A7 MATTRESS - TWIN

A6 TIME ZONAL CLOCK

A5 TRASH CAN - DESK SIDE

A4 SHOWER CURTAIN (SPA CURTAIN)

A3 JANITOR SUPPLY CART

A2 TILT TRUCK - TRASH

MARK NAME

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:1

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-609

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

IN

TE

R

IO

R F

IN

IS

H L

E G

E N

D

ZNK

12794336

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

NOTES: ACOUSTICAL FLEECE

ABOVE CEILING

COLOR: CONSTANTS WALNUT

EDGE: 1/4" REVEAL 15/16"

PATTERN: NOMINAL 6IN PLANK

DIMENSIONS: 24x96x 3/4

COLOR: BLACK #40 PRODUCT #: 6691W1

SIZE: 4" HEIGHT

MODEL: SC-29-4 SYSTEM: WOODWORKS LINEAR

VENEERED PANELS

MANUFACTURER: JOHNSONITE MANUFACTURER: ARMSTRONG

RB2 RUBBER BASE CLG1 WOOD CEILING SYSTEM

COLOR: MOON ROCK #29 09 51 00 WOOD CEILING

SIZE: 4" HEIGHT

MODEL: SC-29-4 GRID COLOR: BLACK

MANUFACTURER: JOHNSONITE NOTE:

NOTE: APPLY PER MFR INSTRUCTIONS

TO INTERIOR GLAZING BETWEEN OPEN

OFFICE 514 AND BLUE OPS 515

GRID: 15/16" EXPOSED TEE

RB1 RUBBER BASE PRODUCT #: PF001-801 WALL PANEL... 1/4" TILE COLOR: BLACK

COLOR: CLEAR COLOR: IVORY WHITE #S029 TILE SIZE: 24x24x1

09 65 00 BASE MANUFACTURER: LG HI-MACS SURFACES EDGE PROFILE: SQUARE

ITEM #: 2820 CALLA

TYPE: 304 STAINLESS STEEL SS2 SOLID SURFACE SHOWER WALLS, AND WINDOW

STOOLS

MANUFACTURER: ARMSTRONG COLOR: CHARCOAL GREY

SERIES: G6 GRIDLINE PRODUCT:

CASPER CLOAKING

TECHNOLOGY

ARCHITECTURAL GLASS

FILMS

ACT2 ACOUSTIC CEILING TILE (AT JTAC) MATERIAL: HDPE

MANUFACTURER: CONSTRUCTION SPECIALTIES MANUFACTURER: DESIGNTEX COLOR: MILKY WAY #T009 STYLE: "Z" STYLE

RM1 RECESSED ENTRANCE MAT WF1 WINDOW FILM SERIES: GALAXY GRID COLOR: WHITE TYPE: TUFFTEC

MANUFACTURER: LG HI-MACS SURFACES GRID: 15/16" EXPOSED TEE MANUFACTURER: SCRANTON PRODUCTS

12 48 13 RECESSED ENTRY MAT WINDOW FILM SS1 SOLID SURFACE COUNTER TOP TILE COLOR: WHITE L1 LOCKERS

TILE SIZE: 24x24x3/4

INSTALLATION MONOLITHIC 06 61 16 SOLID SURFACE EDGE PROFILE: SQUARE 10 51 13 LOCKERS

SIZE: 24x24 OPERATION: MANUAL AT EXTERIOR

WINDOWS

ITEM #: 1910

COLOR: 15139 NIGHT FABRIC COLOR: 0104 SANDSTONE FINISH: TEXTURED MANUFACTURER: ARMSTRONG FINISH: ORANGE PEEL

PRODUCT NAME: BELVEDERE V SERIES: 0100 COLOR #: WM0047T ACT1 ACOUSTIC CEILING TILE COLOR: CHARCOAL GREY

MANUFACTURER: MANNINGTON TYPE: ROOM DARKENING SPACE COLOR: ICONIC MAPLE MATERIAL: HDPE

CPT2 CARPET TILE MANUFACTURER: MECHOSHADE SYSTEMS MANUFACTURER: NEVAMAR 09 51 00 ACOUSTICAL CEILING TILE TYPE: HINEY HIDER

WC2 WINDOW SHADES PL1 PLASTIC LAMINATE MANUFACTURER: SCRANTON PRODUCTS

INSTALLATION MONOLITHIC TP1 TOILET PARTITIONS

SIZE: 24x24 06 41 16 PLASTIC LAMINATE NOTE: HOLLOW METAL DOOR FRAMES AND

EXPOSED STEEL

OPERATION: MANUAL AT EXTERIOR

WINDOWS

COLOR: PORPOISE 10 21 13 TOILET PARTITIONS

COLOR: 6018 STONE COLOR NUMBER: SW7047

COLOR: SYNERGY W/ #1245 / C381

AUTUMN GLORY ACCENT

STRIPE

SERIES: 6000 (3% OPEN) MANUFACTURER: SHERWIN WILLIAMS

PRODUCT NAME: MEDIA TYPE: LIGHT FILTERING SHADES NOTE: SCHLUTER TRANSITION AT TOILET ROOM

WALL AND FLOOR TILE

PNTM4 TYPE: ENAMEL

MANUFACTURER: MANNINGTON MANUFACTURER: MECHOSHADE SYSTEMS FINISH: ANODIZED ALUMINUM NOTE: SCHLUTER PROFILE AT OUTSIDE

CORNERS OF ALL PORCELAIN WALL

TILE

CPT1 CARPET TILE WC1 WINDOW SHADES PRODUCT #: AHK1S100AE NOTE: RESTROOMS AND TRASH/MAINT. FINISH: SATIN ANODIZED ALUMINUM

PRODUCT: DILEX-AHK COLOR: NUANCE PRODUCT #: Q100AE

09 68 00 CARPET TILE 12 24 13 WINDOW SHADES TR3 MANUFACTURER: SCHLUTER SYSTEMS COLOR NUMBER: SW7049 PRODUCT: QUADEC

MANUFACTURER: SHERWIN WILLIAMS MANUFACTURER: SCHLUTER SYSTEMS

PNTE1 TYPE: EPOXY MT1 CORNER GUARD

NOTE: FIELD FLOOR TILE IN

RESTROOMS

NOTE: SCHLUTER TRANSITION AT RESILIENT TO

TILE

NOTE: TRANSITION PIECE AT CARPET TO

RESILIENT FLOORING. REFERENCE

DETAIL A1/I-610

GROUT: GT1 FINISH: SATIN ANODIZED ALUMINUM NOTE: JTAC FIELD PAINT COLOR: #209 SLATE

COLOR: SYNC # 905 PEWTER SIZE: 12x24 PRODUCT #: AE100 COLOR: TRICORN BLACK SIZE: 2"

PRODUCT #: 152 FINISH: MATTE PRODUCT: SCHIENE COLOR NUMBER: SW6258 SERIES: SM-20N

MANUFACTURER: MANNINGTON COLOR: DELORIAN GREY TR2 MANUFACTURER: SCHLUTER SYSTEMS MANUFACTURER: SHERWIN WILLIAMS MATERIAL: VINYL

TR1 FINISHING ACCESORY - TRANSITION PIECE SERIES: HALCYON II PNT4 TYPE: LOW ODOR LATEX MANUFACTURER: C/S GROUP

MANUFACTURER: TRINITY TILE CG2 CORNER GUARD

PT2 FLOOR TILE NOTE:

ACCENT WALL TILE IN RESTROOMS

NOTE: ACCENT PAINT WHERE NOTED

NOTE: ACCENT LVT FLOORING GROUT: GT1 COLOR: BACKDROP COLOR: #934 PEARL

SIZE 12x18 SIZE: 12x24 COLOR NUMBER: SW7025 SIZE: 2"

COLOR: LINEAR STONE SHALE NOTE:

FIELD FLOOR TILE IN LOBBY

FINISH: MATTE MANUFACTURER: SHERWIN WILLIAMS SERIES: SM-20N

PATTERN: #SS5S3606 GROUT: GT1 COLOR: BLUE PNT3 TYPE: LOW ODOR LATEX MATERIAL: VINYL

SERIES: SPACIA SIZE: 12x24 SERIES: ARAGONITE MANUFACTURER: C/S GROUP

MANUFACTURER: MANNINGTON FINISH: MATTE MANUFACTURER: TRINITY TILE NOTE: ACCENT PAINT WHERE NOTED CG1 CORNER GUARD

RF1 RESILIENT FLOORING COLOR: VELVET PWT2 WALL TILE COLOR: AMAZING GRAY

SERIES: EVE COLOR NUMBER: SW7044 MATERIAL: STAINLESS STEEL

09 65 00 RESILIENT FLOORING MANUFACTURER: TRINITY TILE NOTE:

FIELD WALL TILE IN RESTROOMS

MANUFACTURER: SHERWIN WILLIAMS WP2 PROTECTIVE WALL COVERING (AT MOP SINK)

PT1 FLOOR TILE GROUT: GT1 PNT2 TYPE: LOW ODOR LATEX

SIZE: 12x24 COLOR: #934 PEARL

09 30 10 PORCELAIN TILE FINISH: MATTE NOTE: FIELD WALL AND CEILING PAINT

REFERENCE ARCHITECTURAL SPECIFICATION

SECTION FOR COMPLETE PRODUCT SPECIFICATION.

COLOR: DELORIAN GREY COLOR: NUANCE SIZE:

.040" THICK, SEE C4/I-612 FOR HEIGHT

COLOR: #60 DUSTY GRAY SERIES: HALCYON II COLOR NUMBER: SW7049 MATERIAL: VINYL

SEALED & HARDENED MANUFACTURER: LATICRETE MANUFACTURER: TRINITY TILE MANUFACTURER: SHERWIN WILLIAMS MANUFACTURER: C/S GROUP

SC1 CONCRETE FLOORING GT1 EPOXY GROUT PWT1 WALL TILE PNT1 TYPE: LOW ODOR LATEX WP1 PROTECTIVE WALL COVERING

09 90 00 CONCRETE SEALER 09 30 10 GROUT 09 30 10 PORCELAIN WALL TILE 09 90 00 PAINT 10 26 00 WALL PROTECTION

FINISH LEGEND

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

GENERAL INTERIOR NOTES

1. REFER TO SHEET I-609 FOR FINISH LEGEND.

2. ALL WALLS AND CEILINGS TO BE PAINTED PNT1 UNO.

3. ALL HM DOOR FRAMES TO BE PAINTED WITH PNTM4.

4. FOR TRANSITION, BASE, AND WALL PROTECTION DETAILS SEE I-613.

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:1

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-610

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IN

IS

H

S C

H E

D U

LE

ZNK

12794337

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

FINISH SCHEDULE

ROOM

FLOOR BASE WALL

CEILING

NOTESNO. NAME FINISH

100 ENTRY VESTIBULE PT1 RB1 PNT1 PNT1/CLG1

101 WOMENS RESTROOM PT2 PTB1 PWT1/PWT2 PNT1

102 MENS RESTROOM PT2 PTB1 PWT1/ PWT2 PNT1

103 SECURITY CPT1 RB1 PNT1 ACT1

104 SECURITY BUNK CPT1 RB1 PNT1 ACT1

105 CORRIDOR RF1 RB1 PNT1/PNT3 ACT1/ PNT1 SEE I-611 FOR ACCENT WALL

106 TRASH/MANT. SC1 RB1 PNT1 ACT1/ PNT1

107 COMM SC1 RB1 PNT1 ETS

108 ELECTRICAL SC1 RB1 PNT1 ETS

109 MECHANICAL SPACE SC1 RB1 PNT1 ETS

110 FIRE ALARM ROOM SC1 RB1 PNT1 ETS

200 RECEPTION CPT1 RB1 PNT1 ACT1/ PNT1

201 CONFERENCE ROOM CPT1 RB1 PNT1 PNT1/CLG1

202 CONFERENCE ROOM CPT1 RB1 PNT1 PNT1/CLG1

203 BREAKROOM RF1 RB1 PNT1/PNT3 ACT1 SEE I-612 FOR ACCENT WALL

204 TEAM ROOM CPT1 RB1 PNT1 ACT1

205 OFFICE 8 CPT1 RB1 PNT1 ACT1

206 PRINTER CPT1 RB1 PNT1 ACT1

207 CO OFFICE CPT1 RB1 PNT1 ACT1

208 OFFICE 7 CPT1 RB1 PNT1 ACT1

209 OFFICE 6 CPT1 RB1 PNT1 ACT1

210 OFFICE 5 CPT1 RB1 PNT1 ACT1

211 OFFICE 4 CPT1 RB1 PNT1 ACT1

212 OFFICE 3 CPT1 RB1 PNT1 ACT1

213 OFFICE 2 CPT1 RB1 PNT1 ACT1

214 OFFICE 1 CPT1 RB1 PNT1 ACT1

215 GREEN OPS AREA CPT1 RB1 PNT1/PNT3/PNT2 ACT1/ PNT1 SEE I-612 FOR ACCENT WALL, RAISED ACCESS FLOOR (RAF1)

300 CORRIDOR CPT1 RB1 PNT1 ACT1

301 CONFERENCE ROOM CPT1 RB1 PNT1 PNT1/CLG1

302 OFFICE 5 CPT1 RB1 PNT1 ACT1

303 OFFICE 4 CPT1 RB1 PNT1 ACT1

304 OFFICE 3 CPT1 RB1 PNT1 ACT1

305 OFFICE 2 CPT1 RB1 PNT1 ACT1

306 OFFICE 1 CPT1 RB1 PNT1 ACT1

307 CO OFFICE CPT1 RB1 PNT1 ACT1

308 OFFICE 6 CPT1 RB1 PNT1 ACT1

309 TEAM ROOM CPT1 RB1 PNT1 ACT1

310 PURPLE OPS AREA CPT1 RB1 PNT1/PNT3/PNT2 ACT1/ PNT1 SEE I-612 FOR ACCENT WALL, RAISED ACCESS FLOOR (RAF1)

311 BREAKROOM RF1 RB1 PNT1/PNT3 ACT1 SEE I-612 FOR ACCENT WALL

400 JTAC CPT2 RB2 PNT4 ACT2

402 JTAC CONTROL ROOM CPT2 RB2 PNT4 ACT2

500 RECEPTION CPT1 RB1 PNT1 ACT1/PNT1

501 OFFICE 11 CPT1 RB1 PNT1 ACT1

502 OFFICE 10 CPT1 RB1 PNT1 ACT1

503 CONFERENCE ROOM CPT1 RB1 PNT1 PNT1/CLG1

504 OFFICE 9 CPT1 RB1 PNT1 ACT1

505 OFFICE 8 CPT1 RB1 PNT1 ACT1

506 OFFICE 7 CPT1 RB1 PNT1 ACT1

507 OFFICE 6 CPT1 RB1 PNT1 ACT1

508 OFFICE 5 CPT1 RB1 PNT1 ACT1

509 OFFICE 4 CPT1 RB1 PNT1 ACT1

510 OFFICE 3 CPT1 RB1 PNT1 ACT1

511 OFFICE 2 CPT1 RB1 PNT1 ACT1

512 SHARED OFFICE CPT1 RB1 PNT1 ACT1

513 CLOSET CPT1 RB1 PNT1 PNT1

514 OPEN OFFICE CPT1 RB1 PNT1/PNT2 ACT1/ PNT1 SEE I-611 FOR ACCENT WALL

515 BLUE OPS AREA CPT1 RB1 PNT1/PNT3 ACT1 SEE I-611 FOR ACCENT WALL, RAISED ACCESS FLOOR (RAF1)

518 PRINTER CPT1 RB1 PNT1 ACT1

700 COVERED AREA

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

OFFICE 6

OFFICE 5

OFFICE 4

OFFICE 3

SHARED OFFICE

OFFICE 2

OFFICE 9

OFFICE 8

OFFICE 7

OPEN OFFICE

CONFERENCE ROOM

BLUE OPS AREA

MECHANICAL SPACE

CORRIDOR

ELECTRICAL

COMM

OFFICE 11

OFFICE 10

JTAC

SECURITY

ENTRY VESTIBULE

WOMENS RESTROOM

MENS RESTROOM

SECURITY BUNK

BREAKROOM

CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1 CG1

CG1CG1 CG1 CG1 CG1 CG1

CG1

P N

T

P N

T

P N

T

CG1 CG1

PNT3

A 1/

I-6

A 1/

-I-

PNT3

CG1 CG1

I2

I2

CG1

I3

I3

P N

T -3

PRINTER

CG1

A52

CG1

P N

T

CLOSET

PNT3PNT3

JTAC CONTROL ROOM

COVERED AREA

GENERAL INTERIOR NOTES

1. REFER TO SHEET I-609 FOR FINISH LEGEND.

2. ALL WALLS AND CEILINGS TO BE PAINTED PNT1 UNO.

3. ALL HM DOOR FRAMES TO BE PAINTED WITH PNTM4.

4. FOR TRANSITION, BASE, AND WALL PROTECTION DETAILS SEE I-613.

LEGEND

PNTX

CORNER GUARD: CG1, CG2

WALL PROTECTION: WP1, WP2

FLOOR TRANSITION STRIP

INTERIOR ACCENT TAG

SHEET KEYNOTES

MODULAR SYSTEM: INCLUDING WALLS,

DOORS AND

WINDOWS. SEE SHEETS I-614 THRU

I-620

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:2

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-611

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IN

IS

H

P

LA

N

A R

E A

A

ZNK

12794338

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

SCALE: 1/8" = 1'-0" (A-100)

A1

FINISH PLAN - AREA "A"

KEY PLAN

4' 8' 16'0'

A B

PLAN

NORTH

A52 RECESSED WALK OFF MAT (RM1) SEE D4/A-510

I2 ALL WALLS IN RESTROOMS (EXCEPT SIDE WALLS AND WALLS BEHIND

LOCKERS) TO RECEIVE PWT-1 AND PWT-2. SEE INTERIOR ELEVATIONS

FOR LAYOUT

I3 ALL SHOWER BASES TO BE SSF, TYP

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

TEAM ROOM

TRASH/MANT.

CONFERENCE ROOM

PURPLE OPS AREA

TEAM ROOM

OFFICE 5

OFFICE 4

CO OFFICE

OFFICE 6

CONFERENCE ROOM

GREEN OPS AREA

OFFICE 5

OFFICE 6

CO OFFICE

OFFICE 7

OFFICE 1

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 3

OFFICE 2

OFFICE 1

OFFICE 8

CONFERENCE ROOM

FIRE ALARM ROOM

BREAKROOM

BREAKROOM

CORRIDOR

PRINTER

CG2 CG1 CG1

CG1

CG1 CG1 CG1 CG1 CG1

CG1

CG1

CG1CG2CG1

CG1

CG1

CG1

CORRIDOR

A 1/

I-6

A 1/

I-6

P N

T

P N

T

P N

T

P N

T

P N

T

P N

T

PNT2

P N

T

CG1

I1

CG1

CG1CG1

CG1

CG1

GENERAL INTERIOR NOTES

1. REFER TO SHEET I-609 FOR FINISH LEGEND.

2. ALL WALLS AND CEILINGS TO BE PAINTED PNT1 UNO.

3. ALL HM DOOR FRAMES TO BE PAINTED WITH PNTM4.

4. FOR TRANSITION, BASE, AND WALL PROTECTION DETAILS SEE I-613.

LEGEND

PNTX

CORNER GUARD: CG1, CG2

WALL PROTECTION: WP1, WP2

FLOOR TRANSITION STRIP

INTERIOR ACCENT TAG

SHEET KEYNOTES

MODULAR SYSTEM: INCLUDING WALLS,

DOORS AND

WINDOWS. SEE SHEETS I-614 THRU

I-620

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:2

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-612

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F

IN

IS

H

P

LA

N

A R

E A

B

ZNK

12794339

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

SCALE: 1/8" = 1'-0" (A-100)

A1

FINISH PLAN - AREA "B"

KEY PLAN

4' 8' 16'0'

A B

PLAN

NORTH

I1 (3) WALLS AROUND MOP SINK TO HAVE WP2. 48"H PANELS

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

GROUT

PORCELAIN TILE

FLOORING AS

SCHEDULED

WATER VAPOR

CONTROL

SYSTEM/CRACK

SUPPRESSION

MEMBRANE

DOOR FRAME BEYOND

LINE OF FLOOR FINISH

CHANGE OR SEAM

DOOR AS SCHEDULED

ALUMINUM TRANSITION STRIP

RESILIENT FLOORING AS

SCHEDULED

WATER VAPOR CONTROL

SYSTEM

TOP OF SLAB

1/ 4"

M A

X

C CENTER LINE OF DOORL

CENTERLINE OF ADAPTER

DOOR AS SCHEDULED

CARPET FLOORING AS

SCHEDULED

WATER VAPOR CONTROL

SYSTEM

DOOR FRAME BEYOND

RESILIENT TRANSITION

STRIP

RESILIENT FLOORING

AS SCHEDULED

C CENTER LINE OF DOORL

TOP OF SLAB

CARPET FLOORING AS

SCHEDULED

RESILIENT TRANSITION STRIP

RESILIENT FLOORING AS

SCHEDULED

CONTINUOUS WATER

VAPOR CONTROL SYSTEM

TOP OF SLAB

DOOR FRAME BEYOND

RESILIENT TRANSITION

STRIP

SEALED CONCRETE

CENTER LINE OF

FLOOR FINISH

CHANGE OR SEAM

DOOR AS SCHEDULED

RESILIENT FLOORING

AS SCHEDULED

WATER VAPOR CONTROL

SYSTEM

C CENTER LINE OF DOORL

TOP OF SLAB

2"

2"

WALL PROTECTION AS

SCHEDULED

RESILIENT BASE AS

SCHEDULED

TOP OF SLAB

F

IE

LD

V

A R

IA

T

IO

N

2" F

O R

RESILIENT FLOORING

AS SCHEDULED

WATER VAPOR

CONTROL SYSTEM

SCHEDULED

WALL PARTITION

RESILIENT BASE AS

SCHEDULED

CARPET FLOORING AS

SCHEDULED

WATER VAPOR

CONTROL SYSTEM

TOP OF SLAB

SCHEDULED

WALL PARTITION

RESILIENT BASE AS

SCHEDULED

TOP OF SLAB

RESILIENT FLOORING

AS SCHEDULED

WATER VAPOR

CONTROL SYSTEM

SCHEDULED

WALL PARTITION

WALL PROTECTION

AS SCHEDULED

TOP OF SLAB

SCHEDULED

WALL PARTITION

I-613

B4

T O

P O

F W

A

LL

P R

O T

E C

T

IO

N

WALL TILE AS

SCHEDULED

GROUT

THIN SET PORCELAIN

FLOOR TILE AS

SCHEDULED

WATER VAPOR CONTROL

SYSTEM/CRACK

SUPPRESSION MEMBRANE

TOP OF SLAB

COVE-SHAPED TILE TRIM,

TR3

SCHEDULED

PARTITION

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:2

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-613

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

IN

TE

R

IO

R D

E

TA

IL

S

ZNK

12794340

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

SCALE: 6" = 1'-0"

D1

THRESHOLD - PORCELAIN TILE TO RESILIENT

SCALE: 6" = 1'-0"

D4

THRESHOLD - RESILIENT TO CARPET

SCALE: 6" = 1'-0"

C1

THRESHOLD - RESILIENT TO CARPET

SCALE: 6" = 1'-0"

C2

THRESHOLD - SEALED CONCRETE TO RESILIENT

SCALE: 6" = 1'-0"

C5

CORNER GUARD DETAIL

SCALE: 6" = 1'-0" (I-613)

B4

RESILIENT FLOORING TO RESILIENT BASE W/ WALL PROTECTION

(TOE BASE)

SCALE: 6" = 1'-0"

B1

CARPET TO RESILIENT BASE (TOE BASE)

SCALE: 6" = 1'-0"

B2

RESILIENT FLOORING TO RESILIENT BASE (TOE BASE)

SCALE: 3" = 1'-0"

C4

WALL PROTECTION SECTION

SCALE: 6" = 1'-0"

B5

TILE BASE DETAIL

0' 6"3" 9"

0" 1 1/2" 3" 6"

3" = 1'-0"

6" = 1'-0"

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

1 2 3 4 5 6 7 8 9

G

F

E

D

C

B

A

OFFICE 6

OFFICE 5

OFFICE 4

OFFICE 3

SHARED OFFICE

OFFICE 2

OFFICE 9

OFFICE 8

OFFICE 7

OPEN OFFICE

CONFERENCE ROOM

BLUE OPS AREA

MECHANICAL SPACE

CORRIDOR

ELECTRICAL

COMM

OFFICE 11

OFFICE 10

JTAC

SECURITY

COVERED AREA

ENTRY VESTIBULE

WOMENS RESTROOM

MENS RESTROOM

SECURITY BUNK

BREAKROOM

PRINTER

CLOSET

JTAC CONTROL ROOM

M505

M504

M506

M507

M508

M509

M510

M511

M512

M502

M501

M515A

'-3

'-0

'-0

'-0

'-0

'-0

'-0

'-0

T Y

P

'-0

A

LI

G N

ALIGN

A

LI

G N

8' -4

VIF

10'-10 1/2"

A

I-6

A

I-6

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

M515B

MOD1

11'-3"

B

A

D

J

L

P

R

T

C

G

I

K

O

Q

S

H

E F

U V

A D

A C

W X

M N

Z

Y

AA

AB

11'-3" TYP

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS.

XX

MODULAR WALL SYSTEM ELEVATION SYMBOL. SEE

I-617 THRU I-620 FOR ELEVATIONS.

MODULAR WALL NOTES:

• TOTAL OF APPROXIMATELY 778 LINEAR FEET OF 9’-0” TALL DIRTT WALLS –

WILL TIE INTO EXISTING CEILING

• ANODIZED ALUMINUM FINISH ON ALL FRAMING AND POSTS

• TYPICAL DEMISING WALLS OF OFFICES AND MEETING SPACES WILL

HAVE STACKED PAINTED MDF TILES (DIRTT GRADE 1 OFFERING) AND

WRITE AWAY TILES IN CENTER OF ONE WALL

• SURFACE MOUNTED TV’S WHERE SHOWN ON DRAWINGS; WALL

MOUNTED TELEVISIONS INCLUDE SURFACE MOUNTING BRACKETS AND

EXTENSION ARMS FOR VERTICAL ADJUSTABILITY *TV’S BY OTHERS

• ALL SOLID WALLS WILL HAVE DOUBLE INSULATION FOR HIGHER STC

RATING

• TYPICAL FRONTS WILL HAVE PAINTED MDF TILES (DIRTT GRADE 1

OFFERING) WITH CLERESTORY AND FULL HEIGHT GLASS SIDELIGHT

• (1) LARGE MAIN CONFERENCE ROOM WILL HAVE DOUBLE GLAZED (EVIL

TWIN) SYSTEM FOR HIGHER STC RATING AND APPLIED FILM FOR

PRIVACY

• (32) SOLID VENEER (DIRTT GRADE 2 OFFERING) BUTT HINGE DOORS WITH

DROP SEAL AND STANDARD DIRTT HARDWARE

• WALL POWER:

• PRE-MOUNTED MOUNTING BRACKETS AND MODULAR BACK BOXES

• TRIM RINGS AND FACEPLATES

• POWER FEED WHIPS TO ACCOMMODATE THE NUMBER OF OUTLETS

• PRE-WIRED 20 AMP RECEPTACLES

• *ALL DATA DEVICES AND WIRING IS BY OTHERS

• *ALL POWER CONNECTIONS IN THE FIELD ARE BY OTHERS

• *CUTOUTS AND BACK BOXES WILL BE SUPPLIED FOR LIGHT SWITCHES

(WIRING/ DEVICE BY OTHERS)

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:2

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-614

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F F

E

P

LA

N

A R

E A

A

M O

D U

LA

R

W A

LL

S

Y S

TE

M

ZNK

12794341

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

KEY PLAN

A B

PLAN

NORTH

4' 8' 16'0'SCALE: 1/8" = 1'-0" (A-100)

A1

FF&E PLAN - AREA A - MODULAR WALL SYSTEM

7. MODULAR WALL FINISHES TO BE SELECTED FROM MANUFACTURER STANDARDS.

ENSURE COLORS/TEXTURES COORDINATE AS CLOSELY AS POSSIBLE WITH THE FINISH

SELECTIONS FOR ADJACENT CONVENTIONAL WALLS.

6. SEE A/V DRAWINGS FOR ALL EQUIPMENT INFORMATION, COORDINATE WITH

ELECTRICAL AND COMM DRAWINGS. PROVIDE BLOCKING OR BACK PLATING AT ALL

WALL MOUNTED MONITORS AND PROVIDE SUPPORTS FOR ALL CEILING MOUNTED

EQUIPMENT AS REQUIRED. COORDINATE WITH MODULAR WALL MANUFACTURER ALL

REQUIRED/REQUESTED DATA AND ELECTRICAL RECEPTACLES. MODULAR WALL

MANUFACTURER TO PROVIDE FLAT PANEL MOUNTING HARDWARE, COORDINATE WITH

A/V DRAWINGS FOR LOCATIONS.

5. COORDINATE ALL REQUIRED CONDUIT, PIPING, AND CHASES FOR ALL GOVERNMENT

FURNISHED, GOVERNMENT INSTALLED EQUIPMENT.

4. ALL DOOR FRAMES ARE TO BE INSTALLED 4” AWAY FROM ADJACENT PERPENDICULAR

WALLS UNLESS NOTED OTHERWISE.

3. ALL DIMENSIONS ARE TO COLUMN GRIDLINES OR FACE OF FINISHED WALLS OR

SURFACES UNLESS NOTED OTHERWISE.

2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND,

NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION. NOT ALL GRID LINES ARE

CENTER.

1. REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF WORK.

NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION OF INCONSISTENCIES,

CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.DRAWINGS & SPECIFICATIONS ARE

COMPLIMENTARY COMPONENTS OF THE CONTRACT DOCUMENTS.

GENERAL NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

8 9 10 11 12 13 14

G

F

E

D

C

B

A

M305

M304

M306

M303

M307

M302

M308

M210

M212

M214

M213

M207

M211

M209

M208

M202

M205

M201

M301

TEAM ROOM

TRASH/MANT.

CONFERENCE ROOM

PURPLE OPS AREA

TEAM ROOM

OFFICE 5

OFFICE 4

CO OFFICE

OFFICE 6

CONFERENCE ROOM

GREEN OPS AREA

OFFICE 5

OFFICE 6

CO OFFICE

OFFICE 7

OFFICE 1

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 3

OFFICE 2

OFFICE 1

OFFICE 8

CONFERENCE ROOM

FIRE ALARM ROOM

BREAKROOM

BREAKROOM

311 CORRIDOR

PRINTER

'-0

'-0

'-0

T

Y P

'-0

'-0

'-2

'-4

'-4

'-4

T Y

P

'-4

'-4

ALIGN

ALIGN

A

LI

G N

A

LI

G N

VIF

10'-7 1/2"

ALIGN

ALIGN

5'-0" 9'-1"

20'-1 3/4" 21'-2"

ALIGN

ALIGN

'-9

V

IF

5' -1

'-7

A

A

A

A

A

A

A

LI

G N

A

LI

G N

6'-9 1/4" 6'-7 1/4"

A

I-6

A

I-6

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

MOD1

A G

A H

AM

AN

AO

AP

AQ

AR

AU

AV

AW

AX

AF

AE

BQ

BR

BO

BP

BU

BV

BY

BZ

CC

CD

CI

CJ

CM

CN

BA

BB

CH

CG

BH

BG

BC

BD

A S

A T

A L

A C

B F

B E

B K

B L

MOD1

AJ

AI

4'-7 3/4" 10'-10"11'-5 1/4"

CLR

5'-0"

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS.

XX

MODULAR WALL SYSTEM ELEVATION SYMBOL. SEE

I-617 THRU I-620 FOR ELEVATIONS.

MODULAR WALL NOTES:

• TOTAL OF APPROXIMATELY 778 LINEAR FEET OF 9’-0” TALL DIRTT WALLS –

WILL TIE INTO EXISTING CEILING

• ANODIZED ALUMINUM FINISH ON ALL FRAMING AND POSTS

• TYPICAL DEMISING WALLS OF OFFICES AND MEETING SPACES WILL

HAVE STACKED PAINTED MDF TILES (DIRTT GRADE 1 OFFERING) AND

WRITE AWAY TILES IN CENTER OF ONE WALL

• SURFACE MOUNTED TV’S WHERE SHOWN ON DRAWINGS; WALL

MOUNTED TELEVISIONS INCLUDE SURFACE MOUNTING BRACKETS AND

EXTENSION ARMS FOR VERTICAL ADJUSTABILITY *TV’S BY OTHERS

• ALL SOLID WALLS WILL HAVE DOUBLE INSULATION FOR HIGHER STC

RATING

• TYPICAL FRONTS WILL HAVE PAINTED MDF TILES (DIRTT GRADE 1

OFFERING) WITH CLERESTORY AND FULL HEIGHT GLASS SIDELIGHT

• (1) LARGE MAIN CONFERENCE ROOM WILL HAVE DOUBLE GLAZED (EVIL

TWIN) SYSTEM FOR HIGHER STC RATING AND APPLIED FILM FOR

PRIVACY

• (32) SOLID VENEER (DIRTT GRADE 2 OFFERING) BUTT HINGE DOORS WITH

DROP SEAL AND STANDARD DIRTT HARDWARE

• WALL POWER:

• PRE-MOUNTED MOUNTING BRACKETS AND MODULAR BACK BOXES

• TRIM RINGS AND FACEPLATES

• POWER FEED WHIPS TO ACCOMMODATE THE NUMBER OF OUTLETS

• PRE-WIRED 20 AMP RECEPTACLES

• *ALL DATA DEVICES AND WIRING IS BY OTHERS

• *ALL POWER CONNECTIONS IN THE FIELD ARE BY OTHERS

• *CUTOUTS AND BACK BOXES WILL BE SUPPLIED FOR LIGHT SWITCHES

(WIRING/ DEVICE BY OTHERS)

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:2

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-615

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

F F

E

P

LA

N

A R

E A

B

M O

D U

LA

R

W A

LL

S

Y S

TE

M

ZNK

12794342

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

4' 8' 16'0'

KEY PLAN

A B

PLAN

NORTH

SCALE: 1/8" = 1'-0" (A-100)

A1

FF&E PLAN - AREA B - MODULAR WALL SYSTEM

7. MODULAR WALL FINISHES TO BE SELECTED FROM MANUFACTURER STANDARDS.

ENSURE COLORS/TEXTURES COORDINATE AS CLOSELY AS POSSIBLE WITH THE FINISH

SELECTIONS FOR ADJACENT CONVENTIONAL WALLS.

6. SEE A/V DRAWINGS FOR ALL EQUIPMENT INFORMATION, COORDINATE WITH

ELECTRICAL AND COMM DRAWINGS. PROVIDE BLOCKING OR BACK PLATING AT ALL

WALL MOUNTED MONITORS AND PROVIDE SUPPORTS FOR ALL CEILING MOUNTED

EQUIPMENT AS REQUIRED. COORDINATE WITH MODULAR WALL MANUFACTURER ALL

REQUIRED/REQUESTED DATA AND ELECTRICAL RECEPTACLES. MODULAR WALL

MANUFACTURER TO PROVIDE FLAT PANEL MOUNTING HARDWARE, COORDINATE WITH

A/V DRAWINGS FOR LOCATIONS.

5. COORDINATE ALL REQUIRED CONDUIT, PIPING, AND CHASES FOR ALL GOVERNMENT

FURNISHED, GOVERNMENT INSTALLED EQUIPMENT.

4. ALL DOOR FRAMES ARE TO BE INSTALLED 4” AWAY FROM ADJACENT PERPENDICULAR

WALLS UNLESS NOTED OTHERWISE.

3. ALL DIMENSIONS ARE TO COLUMN GRIDLINES OR FACE OF FINISHED WALLS OR

SURFACES UNLESS NOTED OTHERWISE.

2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND,

NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION. NOT ALL GRID LINES ARE

CENTER.

1. REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF WORK.

NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION OF INCONSISTENCIES,

CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.DRAWINGS & SPECIFICATIONS ARE

COMPLIMENTARY COMPONENTS OF THE CONTRACT DOCUMENTS.

GENERAL NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:3

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-616

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

M O

D U

LA

R

W A

LL

S

Y S

TE

M

D E

TA

IL

S

ZNK

12794343

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

MODULAR WALL SYSTEM DOOR SCHEDULE

D O

O R

N O

DOOR

MODULAR WALL

- DIRTT DOOR

PANEL TYPE

MODULAR

WALL - DIRTT

DOOR FINISH

HW Set R E

M A

R K

SSIZE

W

ID

TH

H E

IG

H

T

M201 3'-0" 8'-10" HD40 BHF7 WD 10.0

M202 3'-0" 8'-10" HD41 BHF8 WD 10.0

M205 3'-0" 8'-10" HD40 BHF7 WD 9.0

M207 3'-0" 8'-10" HD41 BHF8 WD 9.0

M208 3'-0" 8'-10" HD41 BHF8 WD 9.0

M209 3'-0" 8'-10" HD40 BHF7 WD 9.0

M210 3'-0" 8'-10" HD41 BHF8 WD 9.0

M211 3'-0" 8'-10" HD40 BHF7 WD 9.0

M212 3'-0" 8'-10" HD41 BHF8 WD 9.0

M213 3'-0" 8'-10" HD40 BHF7 WD 9.0

M214 3'-0" 8'-10" HD41 BHF8 WD 9.0

M301 3'-0" 8'-10" HD40 BHF7 WD 10.0

M302 3'-0" 8'-10" HD40 BHF7 WD 9.0

M303 3'-0" 8'-10" HD40 BHF7 WD 9.0

M304 3'-0" 8'-10" HD40 BHF7 WD 9.0

M305 3'-0" 8'-10" HD41 BHF8 WD 9.0

M306 3'-0" 8'-10" HD40 BHF7 WD 9.0

M307 3'-0" 8'-10" HD41 BHF8 WD 9.0

M308 3'-0" 8'-10" HD40 BHF7 WD 9.0

M501 3'-0" 8'-10" HD45 BHF7 WD 9.0

M502 3'-0" 8'-10" HD44 BHF8 WD 9.0

M504 3'-0" 8'-10" HD44 BHF8 WD 9.0

M505 3'-0" 8'-10" HD45 BHF7 WD 9.0

M506 3'-0" 8'-10" HD44 BHF8 WD 9.0

M507 3'-0" 8'-10" HD45 BHF7 WD 9.0

M508 3'-0" 8'-10" HD44 BHF8 WD 9.0

M509 3'-0" 8'-10" HD45 BHF7 WD 9.0

M510 3'-0" 8'-10" HD44 BHF8 WD 9.0

M511 3'-0" 8'-10" HD45 BHF7 WD 9.0

M512 3'-0" 8'-10" HD45 BHF7 WD 9.0

M515A 3'-0" 8'-10" HD44 BHF8 WD 7.0

M515B 3'-0" 8'-10" HD45 BHF7 WD 7.0

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

Elevation M Elevation N

Elevation E

Elevation F

Elevation K Elevation LElevation I Elevation JElevation G Elevation H

Elevation C Elevation DElevation A Elevation B

HD43

BHF8

HD42

BHF7

HD43

BHF8

HD42

BHF7

HD45

BHF7

HD45

BHF7

HD45

BHF7

HD44

BHF8

HD45

BHF7

HD44

BHF8

HD44

BHF8

HD45

BHF7

HD44

BHF8

HD45

BHF7

HD45

BHF7

HD45

BHF7

HD44

BHF8

HD44

BHF8

'-0

7 _ 8

'-8

3 _ _ 1

'-0

7 _ 8

'-8

3 _ _ 1

'-6

'-4

'-8

3 _ _ 1

"4 '-5

'7

'-6

'-8

3 _ _ 1

'7

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

4'-8 9__

" 4'-8 9__

"4'-8 9__

"4'-8 9__

"4'-8 9__

"4'-8 9__

" 4'-8 9__

" 3'-4"4'-8 9__

" 4'-8 9__

"3'-4"

53'-9 1_

10'-7 11__

3'-4" 2'-5 1_ " 2'-6"3'-6" 2'-4

7_ " 2'-4

7_

" 2'-6"3'-11 15__

" 2'-4 5_

10'-7 5_

2'-6" 3'-4"

10'-7 15__

2'-5"2'-4 11__

"3'-6" 2'-4 13__

"3'-11 15__

" 3'-11 15__

" 3'-4"

10'-7 1_

3'-4"2'-4 11__

"2'-6"2'-6"

10'-7 7__

3'-4"2'-6"2'-6"

10'-8 1_

2'-5 1_ " 2'-4

5_

24'-9 13__

2'-4 13__

"2'-5"3'-4"3'-4"

8'-7 7__

2'-10 1_

" 2'-10 1_ "2'-10

1_

11'-2 7__

3'-8 13__

"3'-8 13__

"3'-8 13__

"2'-10 1_ " 2'-10

1_

" 2'-10 1_

8'-7 7__

3'-8 13__

" 3'-8 13__

"3'-8 13__

11'-2 7__

"8'-7 7__

2'-10 1_ " 2'-10

1_ "2'-10

1_

4'-8 9__

NOTE: ELEVATIONS PROVIDED TO HDR FROM DIRTT.

THEY ARE FOR REFERENCE ONLY. FURNITURE DEALER

RESPONSIBLE FOR VERIFYING ALL CONTENT.

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:3

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-617

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

M O

D U

LA

R

W A

LL

S

Y S

TE

M

E

LE

V A

TI

O

N S

ZNK

12794344

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

2' 4' 8'0'

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

Elevation AI Elevation AJ

Elevation AE Elevation AF Elevation AG

Elevation AH

Elevation U Elevation V Elevation W Elevation X

Elevation Y Elevation Z Elevation AA Elevation AB Elevation AC Elevation AD

Elevation S Elevation TElevation Q Elevation RElevation O Elevation P

HD44

BHF8

HD44

BHF8

HD45

BHF7

HD44

BHF8

HD45

BHF7

HD45

BHF7

HD45

BHF7

HD44

BHF8

HD41

BHF8

HD41

BHF8

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD41

BHF8

HD41

BHF8

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD40

BHF7

3'-4 11__

"3'-4 11__

2'-4 13__

" 2'-4 13__

" 2'-8" 3'-4"

10'-9 5_ " 10'-2

15__

" 10'-8 3__

2'-4 1__

"2'-8"2'-1 1_

" 2'-5 13__

10'-11 3_

2'-5 13__

"2'-8" 2'-5 13__

"2'-1 1_ " 2'-8"

10'-11 11__

3'-4" 2'-4 1__

"2'-5 7_ "3'-4" 2'-5

13__

"2'-8" 3'-4"

10'-11 9__

2'-8" 2'-5 7_

"3'-4" 2'-5 7_

" 3'-4"2'-5 7_

10'-11 9__

2'-8" 3'-4"

2'-6" 2'-11"2'-4 9__

"2'-4 9__

" 2'-11"2'-11"2'-6"

10'-7 1__

" 14'-7 1__

3'-4" 3'-4" 3'-0 5__

" 2'3'-0 5__

17'-5 3__

3'-0 5__

"3'-0 5__

" 3'-4"

3'-5 13__

" 3'-5 13__

"3'-5 13__

10'-5 3_

3'-5 7_

10'-5 5_

3'-5 7_ " 3'-5

7_ " 3'-4"

9'-11 5_

2'-3 13__

" 2'2'-3 13__

3'-8 13__

" 3'-8 13__

11'-2 7__

3'-8 13__

8'-7 7__

2'-10 1_ "2'-10

1_ "2'-10

1_

"3'-8 13__

"3'-8 13__

11'-2 7__

3'-8 13__

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-8

3 _ _ 1

"4 '-5

'-6

'-8

3 _ _ 1

'-6

'-8

3 _ _ 1

'-6

"3 '-4

'-8

3 _ _ 1

"4 '-5

'7

'-6

"3 '-4

'-8

3 _ _ 1

"4 '-5

'7

'-6

'-8

3 _ _ 1

'-6

'-8

3 _ _ 1

'-6

"3 '-4

'-8

3 _ _ 1

"4 '-5

'-6

'-6

"3 '-4

'-6

"3 '-4

'-4

'-8

3 _ _ 1

"4 '-5

'-6

'-8

3 _ _ 1

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

3'-4 11__

10'-2 1__

NOTE: ELEVATIONS PROVIDED TO HDR FROM DIRTT.

THEY ARE FOR REFERENCE ONLY. FURNITURE DEALER

RESPONSIBLE FOR VERIFYING ALL CONTENT.

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:3

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-618

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

M O

D U

LA

R

W A

LL

S

Y S

TE

M

E

LE

V A

TI

O

N S

ZNK

12794345

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

2' 4' 8'0'

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

Elevation AM Elevation AN Elevation AO Elevation AP Elevation AQ

Elevation AR Elevation AU Elevation AV

Elevation AK Elevation AL

Elevation AW Elevation AX

Elevation AS Elevation AT

Elevation BI Elevation BJ

Elevation BA

Elevation BB Elevation BC Elevation BD Elevation BE Elevation BF

Elevation AY Elevation AZ

Elevation BG Elevation BH

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD41

BHF8

HD40

BHF7

HD40

BHF7

HD41

BHF8

3'-4 11__

" 3'-4 11__

" 3'-4 11__

10'-2 1__

3'-4 11__

" 3'-4 11__

10'-2 1__

3'-4 11__

" 3'-4 11__

" 3'-4 11__

10'-2 1__

3'-4 11__

3'-4 11__

" 3'-4 11__

"3'-4 11__

10'-2 1__

3'-4 1__

"3'-4 1__

" 3'-4 1__

10'-0 1_

10'-2 1__

3'-4 11__

" 3'-4 11__

" 3'-4 11__

6'-0 3__

3'-0 1_ " 3'-0

1_

3'-8 1_

"2'-8" 3'-8 1_

" 3'-8 1_ "3'-4" 3'-8

1_

20'-8 7__

2'-4 3_

2'-6"2'-8" 2'-6"

11'-0 1__

3'-4"

3'-8" 3'-8"3'-8"

11'-0 1__

3'-0 1_ " 3'-0

1_ " 3'-0

1_ " 3'-0

1_

12'-0 3_

3'-3 9__

" 3'-3 9__

"3'-3 9__

"3'-3 9__

16'-5 3_

3'-3 9__

3'-4" 2'-6"3'-6 3__

19'-10 5_

3'-10 3_ "3'-4" 3'-10

3_

"3'-6 3__

" 3'-10 3_

"3'-6 3__

" 2'-6"3'-6 3__

21'-3 1_

3'-10 3_

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-4

'-8

3 _ _ 1

'-6

'-8

3 _ _ 1

'7

'-6

'-4

'-6

'-8

3 _ _ 1

'-6

"3 '-4

'-8

3 _ _ 1

"4 '-5

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

'-6

"3 '-4

'-8

3 _ _ 1

'7

'-8

3 _ _ 1

NOTE: ELEVATIONS PROVIDED TO HDR FROM DIRTT.

THEY ARE FOR REFERENCE ONLY. FURNITURE DEALER

RESPONSIBLE FOR VERIFYING ALL CONTENT.

- NOT USED- NOT USED

- NOT USED- NOT USED

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:3

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-619

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

M O

D U

LA

R

W A

LL

S

Y S

TE

M

E

LE

V A

TI

O

N S

ZNK

12794346

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

2' 4' 8'0'

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

Elevation BM

Elevation BN

Elevation BW

Elevation BX

Elevation BS Elevation BT

Elevation BK

Elevation BL

Elevation BU Elevation BV

Elevation BO

Elevation BP

Elevation BQ Elevation BR

Elevation BY Elevation BZ Elevation CC Elevation CD

Elevation CM Elevation CNElevation CI Elevation CJElevation CG Elevation CH

Elevation CA Elevation CB Elevation CE Elevation CF

Elevation CK Elevation CL

HD40

BHF7

HD41

BHF8

HD40

BHF7

HD41

BHF8

HD41

BHF8

HD41

BHF8

HD40

BHF7

HD40

BHF7

HD40

BHF7

HD41

BHF8

HD41

BHF8

HD41

BHF8

HD41

BHF8

HD40

BHF7

HD41

BHF8

HD41

BHF8

12'-0 3_

3'-0 1_ " 3'-0

1_ "3'-0

1_ "3'-0

1_

2'-4 3_

"3'-3 9__

"3'-3 9__

" 3'-3 9__

"3'-3 9__

"3'-3 9__

16'-5 3_

2'-4 11__

" 2'-4 13__

"3'-4"

10'-7 3_

2'-6"2'-6" 2'-6"3'-4"2'-6" 2'-2 3__

"3'-4" 2'-4 7_

10'-7 13__

3'-4"2'-4 15__

9'-2 13__

2'-4 3_

10'-7 7__

2'-4 13__

"2'-4 7_

10'-7 9__

3'-4" 2'-4 15__

10'-7 1_

2'-4 11__

"2'-6"2'-6"3'-4 13__

10'-8 3__

2'-6" 2'-4 3_ "2'-5

1_

"2'-5 1_ " 3'-4"3'-4"

3'-5 5_

10'-4 15__

3'-5 5_ "3'-5

5_

7'-9 15__

3'-10 15__

"3'-10 15__

3'-5 5_

" 3'-5 5_

10'-4 15__

3'-5 5_

3'-10 15__

" 3'-10 15__

7'-9 15__

3'-5 5_

"3'-5 5_

10'-4 15__

3'-5 5_

10'-4 15__

3'-5 5_ "3'-5

5_

" 3'-5 5_ "3'-10

15__

7'-9 15__

3'-10 15__

"3'-4" 1'-6 3_

4'-10 3_

1'-11" 3'-0 1__

" 3'-0 1__

" 3'-0 1__

"3'-0 1__

12'-0 1_

1'-10 13__

"3'-10 3__

'-6

"3 '-4

'-4

'-6

"3 '-4

'-6

"3 '-4

'-6

'-8

3 _ _ 1

'-6

"3 '-4

'-8

3 _ _ 1

"4 '-5

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'-6

"3 '-4

'7

'-6

"3 '-4

'-6

"3 '-4

'-8

3 _ _ 1

'-8

3 _ _ 1

'-4

'-6

"3 '-4

'-6

"3 '-4

'-4

'-4

NOTE: ELEVATIONS PROVIDED TO HDR FROM DIRTT.

THEY ARE FOR REFERENCE ONLY. FURNITURE DEALER

RESPONSIBLE FOR VERIFYING ALL CONTENT.

- NOT USED

- NOT USED

- NOT USED - NOT USED - NOT USED - NOT USED - NOT USED

- NOT USED - NOT USED

- NOT USED - NOT USED

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:3

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-620

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

M O

D U

LA

R

W A

LL

S

Y S

TE

M

E

LE

V A

TI

O

N S

ZNK

12794347

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

2' 4' 8'0'

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

I-

A

I-

2' -9

'-3

2' -9

38'-6"

RAMP

RAMP

RAF1

OFFICE 6

OFFICE 5

OFFICE 4

OFFICE 3

SHARED OFFICE

OFFICE 2

OFFICE 9

OFFICE 8

OFFICE 7

OPEN OFFICE

CONFERENCE ROOM

BLUE OPS AREA

MECHANICAL SPACE

CORRIDOR

ELECTRICAL

COMM

OFFICE 11

OFFICE 10

JTAC

SECURITY

COVERED AREA

ENTRY VESTIBULE

WOMENS RESTROOM

MENS RESTROOM

RECEPTION

SECURITY BUNK

BREAKROOM

PRINTER

CLOSET

JTAC CONTROL ROOM

C3

A-511

C4

A-511

C4

A-511

D4

A-511

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

RAISED ACCESS FLOORING

RAF1 RAISED ACCESS FLOORING CALL OUT

GENERAL NOTES

1. RAF1 = FREEAXEZ GRIDD40 SERIES. 2.75” HIGH, WITH RAMPS.

2. REFER TO SPEC SECTION 09 69 13 LOW PROFILE CABLE MANT ACCESS

FLOORING FOR MORE INFORMATION

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

C A

M P

L E

J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/5

/2

:3

:4

P M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

S

N U

T T

A L L

.r v t

I-621

P M A R

IN

E R A

ID

E R H E A D Q U A R T E R S

C O

LL

A

TE

R A L E Q U

IP

M E N T P

LA

N A R E A A R A

IS

E D A C C E S S F

LO

O R

ZNK

12794348

AVS KLC

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C O

R E

C I

KEY PLAN

A B

PLAN

NORTH

4' 8' 16'0'SCALE: 1/8" = 1'-0" (A-100)

A1

COLLATERAL EQUIPMENT PLAN - AREA A - RAISED ACCESS FLOOR

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

I-

A

I-

RAF1

RAF1

RAMP

R A

M P

RAMP

RAMP

R A

M P

RAMP

24'-9" 5'-0" 2'-9"

2' -9

'-8

1' -1

0" 2'

-9

41'-11" 5'-0" 2'-9"

2' -9

'-8

1' -1

0" 2'

-9

TEAM ROOM

204TRASH/MANT.

CONFERENCE ROOM

PURPLE OPS AREA

TEAM ROOM

OFFICE 5

OFFICE 4

CO OFFICE

OFFICE 6

CONFERENCE ROOM

GREEN OPS AREA

OFFICE 5

OFFICE 6

CO OFFICE

OFFICE 7

OFFICE 1

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 3

OFFICE 2

OFFICE 1

OFFICE 8

CONFERENCE ROOM

FIRE ALARM ROOM

BREAKROOM

BREAKROOM

CORRIDOR

RECEPTION

PRINTER

C3

A-511

C3

A-511

C4

A-511

C4

A-511

C4

A-511

D4

A-511

C4

A-511

C4

A-511

C4

A-511

D4

A-511

D1

A-100

RAMP RAMP

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

RAISED ACCESS FLOORING

RAF1 RAISED ACCESS FLOORING CALL OUT

GENERAL NOTES

1. RAF1 = FREEAXEZ GRIDD40 SERIES. 2.75” HIGH, WITH RAMPS.

2. REFER TO SPEC SECTION 09 69 13 LOW PROFILE CABLE MANT ACCESS

FLOORING FOR MORE INFORMATION

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A V A L F A C

IL

IT

IE

S E N G

IN

E E R

IN

G C O M M A N D M

ID

-A T L A N T

IC

C A

M P

L E

J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/5

/2

:3

:4

P M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

S

N U

T T

A L L

.r v t

I-622

P M A R

IN

E R A

ID

E R H E A D Q U A R T E R S

C O

LL

A

TE

R A L E Q U

IP

M E N T P

LA

N A R E A B R A

IS

E D A C C E S S F

LO

O R

ZNK

12794349

AVS KLC

06/19/2020

Approved by Emily Sylvester, Director of Installation Development Division

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

M

ID

L A

N T

C O

R E

C I

4' 8' 16'0'

KEY PLAN

A B

PLAN

NORTH

SCALE: 1/8" = 1'-0" (A-100)

A1

COLLATERAL EQUIPMENT PLAN - AREA B - RAISED ACCESS FLOOR

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P P

R

R

E V

IS

IO

N

/0

5/

OFFICE 9

OFFICE 8

OFFICE 7

OFFICE 6

OFFICE 5

OFFICE 4

OFFICE 3

OFFICE 2

SHARED OFFICE

OPEN OFFICE

OFFICE 11

OFFICE 10

CONFERENCE ROOM

BLUE OPS AREA

MECHANICAL SPACE

ELECTRICAL

COMM

JTAC

CORRIDOR

MENS RESTROOM

COVERED AREA

WOMENS RESTROOM

SECURITY

SECURITY BUNK

A 1/

I-6

A 1/

I-6

ENTRY VESTIBULE

BREAKROOM

B

C

C

C

C

C

C

C

C

C

C

C

C

D E

F

G

J

A

H

H

H

J J J J

J

H

H

H

K

H

C

CLOSET

PRINTER

JTAC CONTROL ROOM

L

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

X SIGNAGE CALL OUT. SEE ABOVE FOR LEGEND

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

A M

P L

E J E

U N

E

J A

C K

S O

N V

IL

L E

N

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

I E

D

440 S. CHURCH STREET, SUITE 1000

CHARLOTTE, NC 28202

TEL (704)338-6700

/1

/2

:3

:4

A M

C rv t\

\1

-A

-C E

N T

R A

L

P -1

M

A R

IN

E

H Q

M

A N

G U

S .r v t

I-623

P

M

A R

IN

E

R A

ID

E

R H

E A

D Q

U A

R T

E R

S

S

IG

N A

G E

P

LA

N

A R

E A

A

ZNK

12794350

AVS KLC

SGL/RMS

1603164

JA

C

K S

O N

V

IL

LE

, N

O R

T H

C A

R O

LI

N

A M

A R

S O

C

EJA

D J D

DJD

8' 16' 32'0'

KEY PLAN

A B

PLAN

NORTH

L L - EVACUATION SIGN 3

K K - HVAC EMERGENCY SHUTOFF 1

J J - NO SMOKING SIGN 9

H H - ROOM SIGN 13

G G - DIRECTORY SIGN 1

F F - DIRECTORY 2

E E - WOMENS RESTROOM 1

D D - MENS RESTROOM 1

C C - OFFICE SIGN 34

B B - CONFERENCE SIGN 4

A A - ENTRANCE DOOR SIGN 1

SIGN TYPE DESCRIPTION COUNT

BUILDING AREAS A AND B

SIGNAGE LEGEND

SCALE: 1/8" = 1'-0" (A-100)

A1

SIGNAGE PLAN - AREA A

ALL SIGNAGE TO COMPLY WITH UFC 3-120-01

S Y

M D

E S

C R

IP

T

IO

N

D A

TE

A

P

PURPLE OPS AREA

CO OFFICE

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

CONFERENCE ROOM

CORRIDOR

300OFFICE 6

TEAM ROOM

TRASH/MANT.

BREAKROOM

CORRIDOR

FIRE ALARM ROOM

CONFERENCE ROOM

BREAKROOM

203CONFERENCE ROOM

TEAM ROOM

OFFICE 8

PRINTER

CO OFFICE

OFFICE 7

OFFICE 6

OFFICE 5

OFFICE 3

OFFICE 2

OFFICE 1

GREEN OPS AREA

A 1/

I-6

A 1/

I-6

OFFICE 4

B B

B

CC

C

C

C

C

C

C C

C

C

C

C

C

C

CCC

C

F

J J

J

H

H

H

H

J

H

H

L

L

FLOOR PLAN LEGEND

MODULAR SYSTEM: INCLUDING WALLS, DOORS AND

WINDOWS. SEE SHEETS I-614 THRU I-620

X SIGNAGE CALL OUT. SEE ABOVE FOR LEGEND

N O

T F

O R

C O

N S

T R

U C

T

IO

N

P R

E L

IM

IN

A

R Y

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

DRAWFORM REVISION: 17…

This is the start of the file's text. The full file is on GovTribe.