About this file

PART 14 AL

View the file

Other files

File Type Posted
UAS_SATCOM_RELAY_PADS_AND_FACILITY_11005.docx DOCX document
AMENDMENT_0011_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_0010_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_009_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_008_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_007_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
1118648_SPC_03-09-2015.pdf PDF
1118648_DWG_03-09-2015.pdf PDF
AMENDMENT_006_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
1118648_Amendment_2_Continuation_Sheet_2015-03-06.doc DOC document
AMENDMENT_005_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_004_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
PPI_015__Response_Attachments.pdf PDF
AMENDMENT_003_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_002_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part10-FP.pdf PDF
N62470-09-R9034_Part03-CIV.pdf PDF
N62470-09-R9034_Part02-LS.pdf PDF
N62470-09-R9034_Part05-GEO.pdf PDF
11005R_SPECS_Final-EBS_04.13.12_Vol_1.pdf PDF
11005_SPECS_Final-EBS_04.13.12_Vol_2.pdf PDF
N62470-09-R9034_Part08-AR.pdf PDF
N62470-09-R9034_Part04-CIV_(CONT).pdf PDF
N62470-09-R9034_Part11-FP_(CONT).pdf PDF
N62470-09-R9034_Part09-IN.pdf PDF
N62470-09-R9034_Part06-LAND.pdf PDF
N62470-09-R9034_Part13-ME.pdf PDF
AMENDMENT_0001N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part14-EL.pdf PDF
N62470-09-R9034_Part07-ST.pdf PDF
N62470-09-R9034_Part12-PL.pdf PDF
N62470-09-R9034_Part01-GEN.pdf PDF
N62470-09-R9034_Part08-AR.pdf PDF
N62470-09-R9034_Part03-CIV-revised.pdf PDF
Contract_Risk_Assessment_and_QA_Responsibility_Spreadsheet-.pdf PDF
N62470-09-R9034_Part01-GEN.pdf PDF
N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part04-CIV.pdf PDF
11005R_SPECS_Final-EBS_04.13.12_Vol_1.pdf PDF
11005_SPECS_Final-EBS_04.13.12_Vol_2.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C

ST

dI

CH/1

MPR

PF-1

EDM

ZONE 2 HAZARDOUS LOCATION

SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES AND CEILING

MOUNTED DEVICES.

INSTALL ALL EQUIPMENT AND DEVICES AT THE HEIGHT INDICATED ON THIS SHEET

UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR

SPECIAL MOUNTING HEIGHTS AND LOCATIONS OF ELECTRICAL DEVICES. MOUNTING

HEIGHTS AND LOCATIONS INDICATED ON ARCHITECTURAL ELEVATIONS TAKE PRECEDENCE

OVER MOUNTING HEIGHTS AND LOCATIONS INDICATED ON THE ELECTRICAL PLANS.

LIGHTING FIXTURES INDICATED AS FOLLOWS: UPPER CASE LETTER WITH NUMERAL

DENOTES FIXTURE TYPE (SEE LIGHTING FIXTURE SCHEDULE ON SHEET EL701 AND EL702),

LOWER CASE LETTER (IF SHOWN) DENOTES SWITCHING ARRANGEMENT.

DEVICES MOUNTED OVER COUNTER TOP SHALL BE 25mm ABOVE THE BACKSPLASH TO

THE BOTTOM. COORDINATE WITH ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION AND

MOUNTING HEIGHT.

SMH - SECONDARY POWER). SEE B1/ES502 FOR DETAIL.

MULTIFUNCTION PROTECTIVE RELAY WITH THE FOLLOWING

PROTECTIVE TRIP FUNCTIONS:

51N

- INSTANTANEOUS OVERCURRENT

- GROUND FAULT CURRENT

- OVER CURRENT

UNLESS INDICATED OTHERWISE, REMOVAL OF UNDERGROUND UTILITIES INCLUDES COMPLETE

REMOVAL OF ALL CABLES, CONDUITS, CONCRETE ENCASED DUCTS, HANDHOLES, AND

MANHOLES. NOTHING IS TO BE ABANDONED UNLESS SPECIFICALLY INDICATED.

PANEL SCHEDULE THERMAL MAGNETIC CIRCUIT BREAKER

NEUTRAL CONNECTION AS INDICATED.

PHASE CONDUCTORS AS INDICATED

WITH GROUND FAULT TRIP IDENTIFICATION.

PANEL SCHEDULE THERMAL MAGNETIC CIRCUIT BREAKER

IDENTIFICATION.

PHASE CONDUCTORS AS INDICATED

NEUTRAL CONNECTION AS INDICATED.

ENCLOSED CIRCUIT BREAKER. MOUNT AT 1.5m ABOVE FINISHED

FLOOR TO BOTTOM.

I d

SINGLE LINE DIAGRAM LEGEND

EQUIPMENT OR CIRCUITS

ELECTRONIC DIGITAL POWER METER

3 POTENTIAL TRANSFORMERS 380V TO 220V RATIO.

3 CURRENT TRANSFORMERS CURRENT RATIO

AS INDICATED.

100A 4P

SCREENED LINE INDICATES EXISTING EQUIPMENT

BOLD LINE INDICATES NEW

OR CIRCUITS.

SWITCH

TRANSFORMER

20KV CABLE TERMINATION

CIRCUIT BREAKER WITH GROUND FAULT INTERRUPTING

DEVICE.

SOLID STATE CIRCUIT BREAKER WITH ADJUSTABLE LONGTIME,

SHORT TIME AND INSTANTANEOUS TRIP UNITS.

EXISTING CABLE TERMINATION

EXISTING SWITCH

SUBSCRIPT INDICATES THE SIZE OF THE CAPACITOR BANK.

AUTOMATIC POWER FACTOR COMPENSATING UNIT.

SURGE ARRESTER.

EH1

SS

K

APPARECCHIATURA O QUADRO CUI LE ALIMENTAZIONI

POZZETTO ESISTENTE (EMH - FM ESISTENTE,

CABINA

CONTATORE ELETTRONICO DIGITALE

3 TRASFORMATORI DI TENSIONE, RAPPORTO 380V/220V

3 TRASFORMATORI DI CORRENTE, RAPPORTO DI

CORRENTE COME INDICATO

LA LINEA RETINATA INDICA APPARECCHIATURE

O CIRCUITI NUOVI

CAVIDOTTO PRIMARIO INTERRATO.

CAVIDOTTO PRIMARIO INTERRATO ESISTENTE.

CAVIDOTTO COMUNICAZIONI INTERRATO.

CAVIDOTTO COMUNICAZIONI INTERRATO ESISTENTE.

CAVIDOTTO ALIMENTAZIONE SECONDARIA INTERRATO.

CIRCUITO LUCE INTERRATO ESISTENTE DA RIMUOVERE.

CIRCUITO LUCE INTERRATO. 2x6+1x6T IN TUBO DIRETTAMENTE INTERRATO DA 50 mm SE NON ALTRIMENTI INDICATO.

LA LINEA RETINATA INDICA APPARECCHIATURE

O CIRCUITI ESISTENTI

SEZIONATORE

TERMINALE CAVO 24KV

TRASFORMATORE

INTERRUTTORE CON NUMERO DI POLI E TARATURA DI

INTERRUTTORE CON DISPOSITIVO DI INTERRUZIONE

INTERRUTTORE CON BOBINA DI APERTURA.

PER GUASTO A TERRA.

INTERVENTO COME INDICATO.

LEGENDA SCHEMA UNIFILARE

FOGLIO SUL QUALE PROSEGUE L'ALIMENTAZIONE

RIFERIMENTO ALIMENTAZIONE

CONTINUAZIONE ALIMENTAZIONE

INTERRUTTORE

CLORURO DI POLIVINILEREFRIGERATORE ACQUA ELETTRICO

RISC.TO/VENT.NE/ARIA CONDIZIONATA

SCARICA ALTA INTENSITA'

VENTILATORE DI ESPULSIONE

UNITA' TRATTAMENTO ARIA

VOLT

TRASFORMATORE

VOLT-AMPERE

CHILOWATT

PRESA

CHILOWATTORA

CHILOAMPERE

CHILOVOLT

TUBO

TERRA

NOTES

ABBREVIAZIONI

CHILOVOLTAMPERE

CREPUSCOLARE

CMH - COMUNICAZIONI ESISTENTI)

SONO COLLEGATE

CABINA

IL PEDICE INDICA LA POTENZA DELLA BATTERIA DEI CONDENSATORI.

UNITA' DI RIFASAMENTO AUTOMATICO.

CHIAVE DI INTERBLOCCO

SEZIONATORE DI TERRA A 24 KV.

LAMPADA SPIA NEL QUADRO A 24 KV.

SEZIONATORE ROTATIVO CON LAME DI TERRA.

PALO ESISTENTE PER ILLUMINAZIONE AREE/STRADALE CON

PALO PER ILLUMINAZIONE AREE/STRADALE CON CORPO ILLUMINANTE.

- LE LETTERE INDICANO I CAVI ESISTENTI.A

- I NUMERI INDICANO I CAVI.1

CORPO ILLUMINANTE ESISTENTE.

INDICAZIONE QUADRO.

SPINTEROMETRO

ARCHITETTONICI L'ESATTA POSIZIONE E PER LE ALTEZZE DI MONTAGGIO.

DALLA PARTE INFERIORE SOPRA IL PARASPRUZZI. COORDINARE CON I PROSPETTI

I DISPOSITIVI MONTATI SOPRA IL PIANO DEL BANCONE DOVRANNO STARE A 25mm

L'INDICAZIONE DEI CORPI ILLUMINANTI E' LA SEGUENTE: LA LETTERA VICINO ALLA

PARTE SUPERIORE DEL CORPO COL NUMERO INDICA IL TIPO DI CORPO ILLUMINANTE

(VEDERE TABELLA CORPI ILLUMINANTI), LA LETTERA IN BASSO (SE MOSTRATA) INDICA

IL TIPO DI ACCENSIONE E LA NUMERAZIONE DELLO STESSO (SE MOSTRATA) INDICA IL

SUULE POSIZIONI INDICATE SULLE PLANIMETRIE ELETTRICHE.

INSTALLARE TUTTE LE APPARECCHIATURE E I DISPOSITIVI ALLE ALTEZZE INDICATE SU

QUESTO FOGLIO, SE NON ALTRIMENTI INDICATO. RIFERIRSI ALLE SERIE DEI PROSPETTI

ARCHITETTONICI INTERNI PER LE ALTEZZE SPECIALI DI MONTAGGIO E PER LA POSIZIONE

DEI DISPOSITIVI ELETTRICI. LE ALTEZZE DI MONTAGGIO E LE POSIZIONI INDICATE SUI

PROSPETTI ARCHITETTONICI HANNO LA PRECEDENZA SULLE ALTEZZE DI MONTAGGIO E

VEDERE LA SERIE DELLE PIANTE DEL CONTROSOFFITTO PER LA POSIZIONE

ESATTA DEI CORPI ILLUMINANTI E DEI DISPOSITIVI MONTATI A SOFFITTO.

NUMERO DEL CIRCUITO.

4.

3.

2.

1.

VENTILATORE DI MANDATA

POZZETTO (PMH - ALIMENTAZIONE PRIMARIA, TMH -

TELECOMUNICAZIONI, SMH - ALIMENTAZIONE SECONDARIA). VEDERE

B1/ES502 PER IL PARTICOLARE.

INTERRUTTORE ALLO STATO SOLIDO CON SGANCIATORI

REGOLABILI A TEMPO LUNGO, BREVE E ISTANTANEO.

APPARECCHIATURA IDONEA PER USO

IN ZONA 2 DI PERICOLO.

TERMINALE CAVO ESISTENTE

SEZIONATORE ESISTENTE

NOTE

SEZIONATORE MONTATO SU PEDANA ESISTENTE.

IDENTIFICAZIONE INTERRUTTORE MAGNETOTERMICO

CONDUTTORI DI FASE COME INDICATO

COLLEGAMENTO DI NEUTRO COME INDICATO

IDENTIFICAZIONE INTERRUTTORE MAGNETOTERMICO CON

DIFFERENZIALE SU TABELLA QUADRI

CONDUTTORI DI FASE COME INDICATO

COLLEGAMENTO DI NEUTRO COME INDICATO

SCARICATORI DI SOVRATENSIONE IN PARALLELO.

- SOVRACORRENTE51

- CORRENTE DI GUASTO A TERRA

- SOVRACORRENTE ISTANTANEA

51N

FUNZIONI DI INTERVENTO:

RELE' MULTIFUNZIONE DI PROTEZIONE CON LE SEGUENTI

INTERRUTTORE SCATOLATO. MONTARE AT 1.5m SOPRA IL PAVIMENTO

FINITO DAL BASSO.

5. SE NON ALTRIMENTI INDICATO, LA RIMOZIONE DEI SERVIZI INTERRATI COMPRENDE LA

COMPLETA RIMOZIONE DI TUTTI I CAVI, DEI TUBI, DEI CAVIDOTTI INCASSATI NEL

CALCESTRUZZO, POZZETTI E PASSI D'UOMO. NIENTE DEVE ESSERE ABBANDONATO SE

NON SPECIFICAMENTE INDICATO.

SEZIONE DEL CAVIDOTTO VISTO IN DIREZIONE DELLE FRECCE, LA

LINEA INGROSSATA INDICA LA PARTE INFERIORE DEL CAVIDOTTO.

VEDERE TABELLA CAVIDOTTI SUI FOGLI EP701.

LE SCRITTE INDICANO QUANTO SEGUE:

SITE LEGEND

DUL

UL

US

EUC

UC

EUP

UP

DUCT BANK SECTION LOOKING IN THE DIRECTION OF ARROWS,

HEAVY LINE INDICATES BOTTOM OF DUCT BANK. SEE DUCT BANK

CABLE SCHEDULE ON SHEET EP701.

SUBSCRIPTS DENOTES THE FOLLOWING:

- LETTERS INDICATE EXISTING CABLES.

- NUMBERS INDICATE CABLES1

A

- SPARE

POLYVINYL CHLORIDE

HEATING/VENTILATING/AIR CONDITIONING

HIGH INTENSITY DISCHARGE

AIR HANDLING UNIT

ELECTRIC WATER COOLER

VOLTS

VOLT-AMPERES

TRANSFORMER

SUPPLY FAN

VA

XFMR

V

SF

KILOWATT-HOURS

PHOTOCELL

RECEPTACLE

PC

REC

KWH

PVC

KILO-AMPERES

KILO-WATTS

KILO-VOLTSKV

KW

HID

KA

GROUND

EXHAUST FAN

HVAC

GND

EWC

EF

CONDUIT

AHU

C

NOTES

ABBREVIATIONS

KILO-VOLTS-AMPERESKVA

EQUIPMENT LISTED FOR USE IN AEX

EXISTING AREA/STREET LIGHTING POLE WITH EXISTING LUMINAIRE.

MANHOLE (PMH - PRIMARY POWER, CMH - TELECOMMUNICATIONS)

EXISTING MANHOLE (EMH - EXISTING POWER,

AREA/STREET LIGHTING POLE WITH LUMINAIRE.

A

B

HANDHOLE (HHL - LIGHTING CIRCUIT HANDHOLE, PHH - POWER CIRCUIT

HANDHOLE, CHH - COMMUNICATIONS HANDHOLE, FHH-FIBER OPTIC

CABLE HANDHOLE). SEE A1/ES502 FOR DETAIL.

SUBSTATION

PANELBOARD DESIGNATION.

DIAGRAM FOR SIZE OF MAIN CIRCUIT BREAKER.

MAIN CIRCUIT BREAKER. SEE ASSOCIATED PANEL SCHEDULE

UNDERGROUND PRIMARY DUCT BANK.

EXISTING UNDERGROUND PRIMARY DUCT BANK.

UNDERGROUND COMMUNICATION DUCT BANK.

EXISTING UNDERGROUND COMMUNICATION DUCT BANK.

UNDERGROUND SECONDARY POWER DUCT BANK.

REMOVE EXISTING UNDERGROUND LIGHTING CIRCUIT.

UNDERGROUND LIGHTING CIRCUIT. 2x6 + 1x6 GROUND IN 50mm DIRECT BURIED CONDUIT UNLESS OTHERWISE NOTED.

CIRCUIT BREAKER WITH NUMBER OF POLES AND TRIP

CIRCUIT BREAKER WITH SHUNT TRIP DEVICE.

RATING AS INDICATED.

EQUIPMENT OR PANEL TO WHICH FEEDER IS CONNECTED

SHEET ON WHICH FEEDER IS CONTINUED

FEEDER REFERENCE

FEEDER CONTINUATION SYMBOL 1.

2.

3.

4.

CMH - EXISTING COMMUNICATIONS)

EXISTING SUBSTATION

EXISTING PAD MOUNTED SWITCH.

PARALLEL CONNECTED TRANSIENT SURGE PROTECTIVE DEVICE.

KEY INTERLOCK

24kV GROUND ISOLATION SWITCH

INDICATOR LIGHT IN 24kV SWITCHGEAR

24kV ROTARY SWITCH WITH GROUNDING POSITION

5.

CAVIDOTTO INTERRATO PER ALIMENTAZIONI SECONDARIE E PER

FEEDERS AI QUADRETTI DEI SATELLITI

USF UNDERGROUND SECONDARY POWER DUCT BANK FOR SATELLITE

PANELBOARD FEEDERS.

CAVIDOTTO INTERRATO PER CAVI COMUNICAZIONI DEI SATELLITI.

UCS UNDERGROUND COMMUNICATIONS DUCT BANK FOR SATELLITE

COMMUNICATIONS CABLES.

POZZETTO DI INFILAGGIO (HHL - LUCE, PHH - POTENZA, CHH -

TELECOMUNICAZIONI, FHH - FIBRA OTTICA). PER PARTICOLARI VEDERE

DISEGNO A1/ES502.

100A 4P

100A 4P

100A 4P

FCS UNDERGROUND FUEL CELL DUCT BANK. (OPTION ITEM No. 1) CAVIDOTTO INTERRATO PER CELLA A COMBUSTIBILE. (OPZIONE No. 1)

LEGENDA SCHEMA UNIFILARE

GC DIREC BURIED 95mm² BARE COPPER GROUNDING CONDUCTOR AT 810mm

BELOW FINISHED GRADE.

CONDUTTORE DI TERRA IN RAME 95mm2 DIRETTAMENTE INTERRATO A 810mm AL DI SOTTO

DEL PIANO DI CAMPAGNA.

INTERRUTTORE GENERALE. PER I DATI VEDI SCHEMA E TABELLA

DEL QUADRO ASSOCIATO.

AP AUTOMATIC TRANSFER SWITCH.

COMMUTATORE AUTOMATICO

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 1

EL

EC

TR

IC

AL

LE

GE

ND

EG001

CA

DRS SAE KLM

LE

GE

ND

A

EL

ET

TR

IC

O

14024869

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

PE

a a

A1

NOTED.

RECEPTACLES IN FLUSH FLOOR BOX. SEE DETAIL C4/EP503 FOR REQUIREMENTS.

ST- EQ#

DS1

a

P

WP

DISPOSITIVI DI COLLEGAMENTO (CONTINUAZIONE)

LA LETTERA PER IL SIMBOLO DELL'INTERRUTTORE INDICA LA FUNZIONE.

PRESA SPECIALE. TENSIONE E CORRENTE COME INDICATO MONTATA A 457mm

PRESA MONTATA A FILO SOFFITTO. FORNIRE DUE PRESE SINGOLE TIPO ITALIANO

MONTATO A 1.2m DAL PAVIMENTO FINITO AL CENTRO SALVO DOVE DIVERSAMENTE

DEVIATORE BIPOLARE 220V VOLTS, 16A SALVO ALTRIMENTI INDICATO.

DAL PAVIMENTO FINITO AL CENTRO SALVO DOVE DIVERSAMENTE INDICATO.

A 1,2 m. IN ASSE COL PAVIMENTO FINITO SE NON ALTRIMENTI INDICATO.

INTERRUTTORE BIPOLARE 220 V, 16 A SE NON ALTRIMENTI INDICATO. MONTARE

1P+N+G, 16A, 220V.

INDICATO.

DISPOSITIVI DI COLLEGAMENTO

LE LETTERE DEI SIMBOLI DELLE PRESE BASE DENOTANO LA FUNZIONE.

PRESA CON DISPOSITIVO DIFFERENZIALE

COPERCHIO STAGNO PER L'APPARECCHIO MOSTRATO.

LE ALTEZZE DI MONTAGGIO SONO IN METRI.

INDICA L'ALTEZZA DI MONTAGGIO SOPRA IL PAVIMENTO FINITO.

PRESA MONTATA A 100mm IN ASSE SOPRA IL BANCONE.

SCATOLA A DUE SCOMPARTI CON PLACCA DOPPIA. MONTARE A 457 mm.

IN ASSE SOPRA IL PAVIMENTO FINITO SE NON ALTRIMENTI INDICATO.

PRESA A PARETE. 2 PRESE SINGOLE 220 V, 16 A, 2P +T TIPO ITALIANO IN

INCORPORATO.

COPERCHIO STAGNO PER L'APPARECCHIO MOSTRATO.

INDICA L'INTERRUTTORE DI COMANDO

INTERRUTTORE CON GEmmA LUMINOSA

INDICATORE DI USCITA, A PARETE. FRECCE DIREZIONALI COME INDICATO.

INDICATORE DI USCITA, A SOFFITTO O PENDENTE: LA PARTE OMBREGGIATA

FARETTO INCASSATO (CON UNITA' DI EMERGENZA)

INDICA LE FACCE. FRECCE DIREZIONALI COME INDICATO.

600x1200mm FLUORESCENTE

600x1200mm FLUORESCENTE

VARI

PUNTO DI RIMOZIONE, DEMOLIZIONE.

COMANDO FOTOELETTRICO

PUNTO DI COLLEGAMENTO, ESISTENTE COL NUOVO LAVORO

TERRA ELETTRICA

RIFERIMENTO SUI SINGOLI DISEGNI)

SIMBOLO PER NOTA DI RIFERIMENTO (VEDERE NOTE DI

300x1200mm FLUORESCENTE

PRESA ITALIANA 220V, 16A, 1P+N+T, PER BEVERINO

ELETTRICO.

SOFFITTO FINITO, SE NON ALTRIMENTI INDICATO.

ITALIANE 2P + T, 6A, 220V. MONTARE A 300mm AL DI SOTTO DEL

PRESA PER TELEVISIONE. FORNIRE DUE PRESE SINGOLE TIPO

TIPO DI APPARECCHIO. VEDERE TABELLA APPARECCHI, FOGLIO EL701 .

LINEARE FLUORESCENTE.

APPARECCHIO A PARETE. MONTARE A 100 MM DALL’INFISSO DELLA PORTA. (CON UNITA' DI EMERGENZA).

APPARECCHIO A PARETE.

FARETTO INCASSATO O APPARECCHI A SCARICA AD ALTA INTENSITA' (HID).

STRISCIA FLUORESCENTE O APPARECCHIO INDUSTRIALE (CON UNITA' DI EMERGENZA).

STRISCIA FLUORESCENTE, APPARECCHIO INDUSTRIALE O PENDENTE.

SEZIONATORE SENZA FUSIBILI. VEDERE TABELLA SEZIONATORI SUI FOGLIO

EP701. MONTARE A 1.5m SOPRA IL PAVIMENTO FINITO DALL'ALTO.

COMBINAZIONE AVVIATORE MAGNETICO IRREVERSIBILE/SEZIONATORE, A

PIENA TENSIONE. VEDERE TABELLA AVVIATORI MOTORE SUI FOGLI EP702.

MONTARE A 1.5m DAL BASSO SOPRA IL

PAVIMENTO FINITO. EQ# INDICA L'APPARECCHIATURA ALIMENTATA.

PULSANTE "DISALIMENTAZIONE DI EMERGENZA" CON CONTATTO ISTANTANEO NORMALMENTE APERTO TARATO A 16A, 220V. MONTARE A 1.8 m DALLA PARTE INFERIORE IN ASSE COL PAVIMENTO.

CORPI ILLUMINANTI

PRESE IN SCATOLE INCASSATE A PAVIMENTO. VEDI PARTICOLARE C4/EP503 PER LE CARATTERISTICHE

RECEPTACLE MOUNTED IN FLUSH CEILING. PROVIDE TWO SINGLE 220V, 16A, 1P +

3-WAY, SINGLE POLE SWITCH RATED 220 VOLTS, 16 AMPS UNLESS OTHERWISE NOTED.

MOUNT AT 1.2m ABOVE FINISHED FLOOR TO CENTER UNLESS OTHERWISE NOTED.

UNLESS NOTED OTHERWISE. MOUNT AT 1.2m ABOVE FINISHED FLOOR TO

DOUBLE POLE SWITCH RATED 220 VOLTS, 16 AMPS

CENTER UNLESS OTHERWISE NOTED.

SCHEDULE ON SHEET EP702.

NON-FUSIBLE DISCONNECT SWITCH. SEE DISCONNECT SWITCH

MOUNT AT 1.5m ABOVE FINISHED FLOOR TO TOP.

MOUNT AT 300mm BELOW FINISHED CEILING UNLESS OTHERWISE

TELEVISION OUTLET. PROVIDE TWO 220V, 16A, 2P + G,

ITALIAN RECEPTACLE.

ONE 220V, 16A, 1P + N + G, ITALIAN RECEPTACLE FOR

SPECIAL RECEPTACLE. VOLTAGE AND CURRENT RATING AS INDICATED.

MOUNT AT 457mm ABOVE FINISHED FLOOR TO CENTER UNLESS OTHERWISE NOTED.

RECEPTACLE, WALL MOUNTED. TWO SINGLE 220V, 16A, 2P + G.

ITALIAN RECEPTACLES IN A TWO-GANG BOX WITH A TWO GANG

SUBSCRIPT FOR BASIC RECEPTACLE SYMBOL DENOTING FUNCTION.

WEATHER PROOF COVER FOR DEVICE SHOWN.

FAULT CIRCUIT INTERRUPTING MECHANISM.

RECEPTACLE WITH BUILT-IN GROUND

INDICATES MOUNTING HEIGHT ABOVE FINISHED FLOOR.

COVER PLATE. MOUNT AT 457mm ABOVE FINISHED FLOOR TO CENTER

RECEPTACLE MOUNTED 100mm ABOVE COUNTER TOP TO CENTER.

ELECTRIC WATER COOLER

MOUNTING HEIGHT IS IN METERS.

LINE UNLESS OTHERWISE NOTED.

"EMERGENCY POWER OFF" PUSH BUTTON WITH NORMALLY OPEN, MOMENTARY CONTACT RATED

FOR 16A, 220V. MOUNT 1.8m ABOVE FINISHED FLOOR TO BOTTOM.

WEATHER PROOF COVER FOR DEVICE SHOWN.

SUBSCRIPT FOR SWITCH SYMBOL DENOTES FUNCTION.

SWITCH WITH PILOT LIGHT

INDICATES SWITCH LEGS

LUMINAIRE TYPE. SEE LUMINAIRE SCHEDULE, SHEETS EL701.

WALL MOUNTED LUMINAIRE. MOUNT AT 100mm ABOVE DOOR FRAME. (BATTERY BALLAST)

LINEAR FLUORESCENT.

WALL MOUNTED LUMINAIRE.

LIGHTING

RECESSED DOWN LIGHT OR HIGH INTENSITY DISCHARGE FIXTURE (HID)

PORTION DENOTES FACE(S). DIRECTIONAL ARROWS AS INDICATED.

FLUORESCENT STRIP OR INDUSTRIAL LUMINAIRE. (BATTERY BALLAST)

WALL MOUNTED EXIT SIGN. DIRECTIONAL ARROWS AS INDICATED. MOUNT AT 100mm ABOVE DOOR FRAME.

FLUORESCENT STRIP, INDUSTRIAL LUMINAIRE OR PENDANT.

RECESSED DOWN LIGHT. (BATTERY BALLAST)

EXIT SIGN, CEILING OR PENDANT MOUNTED: SHADED

600mm X 1200mm FLUORESCENT.

600mm X 1200mm FLUORESCENT. (BATTERY BALLAST)

MISCELLANEOUS

POINT OF REMOVAL , DEMOLITION.

PHOTOELECTRIC CONTROLLER.

POINT OF CONNECTION, EXISTING TO NEW WORK.

ELECTRICAL GROUND. PROVIDE INSPECTION WELL AT EACH GROUND

ROD CONNECTION. SEE C1/EQ501 FOR DETAIL.

KEY NOTE SYMBOL. (SEE KEY NOTES ON INDIVIDUAL DRAWINGS).

300mm X 1200mm FLUORESCENT. (BATTERY BALLAST)COMBINATION FULL VOLTAGE, NON-REVERSING MAGNETIC MOTOR STARTER/DISCONNECT

SWITCH. SEE MOTOR STARTER SCHEDULE ON SHEET EP702.

MOUNT AT 1.5m ABOVE FINISHED FLOOR TO BOTTOM. EQ# INDICATES EQUIPMENTSERVED.

EPO

G

WP

TV

OC

EWC

+1.2

WIRING DEVICES (CONTINUED)

N + G ITALIAN RECEPTACLE.

WIRING DEVICES

FLUORESCENT DIMMER SWITCH.

VARIATORE LUMUNOSO PER LAMPADE FLUORESCENTI.

PUNTO DI COLLEGAMENTO A TERRA. PER PARTICOLARI VEDERE B3/EP503.

GROUNDING POINT. SEE DETAIL B3/EP503.

PROVIDE TWO SINGLE 120V, 16A, 2P + G USA TYPE RECEPTACLES IN ADDITION TO THE 220V, 16A, 2P + G, ITALIAN RECEPTACLE. MOUNT ITALIAN AND USA TYPE RECEPTACLES IN SEPARATE BOXES SEE B1/EP503 FOR DETAIL

D

PROVEDERE DUE PRESE SINGOLE TIPO USA A 120V, 16A, 2P + T, IN AGGIUNTA A UNA PRESA ITALIANA 220V, 16A, 2P + T. MOTARE LE PRESE ITALIANE E USA IN SCATOLE SEPARATE. VEDI B1/EP503 PER IL PARTICOLARE.

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 1

EL

EC

TR

IC

AL

LE

GE

ND

EG002

CA

DRS SAE KLM

LE

GE

ND

A

EL

ET

TR

IC

O

14024870

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

TUBI E CONDUTTORI

TUTTI I CAVI SONO UNIPOLARI

CONDUTTORE (mmq)

NUMERO DI CAVI

SEZIONE DEL

IN PARALLELI

NOTA:

NUMERO DEI CONDUTTORI

CODICE TUBO E SEZIONE

CONDUTTORE

MISURA DEL TUBO (mm)

DISTRIBUZIONE ENERGIA ELETTRICA

QUADRO, MONTATO IN VISTA.

2x2,5mmq + 1x2,5mmq T/16 QUANDO NON SONO INDICATE LINEE DI

IDENTIFICAZIONE, SE NON ALTRIMENTI INDICATO. LA LINEA CORTA

INDICA IL NUMERO DEI CONDUTTORI DI FASE DA 2,5 mmq, LA

LINEA LUNGA INDICA IL NUMERO DEI CONDUTTORI DI NEUTRO DA

2,5 mmq. I CONDUTTORI DI TERRA SONO RICHIESTI MA NON

PERCORSO AL QUADRO. IL PEDICE INDICA IL NOME DEL QUADRO E

LA DESIGNAZIONE DEL CIRCUITO. TUTTI I CONDUTTORI SONO 2x2,5 + 1x2,5 T/16, SE NON ALTRIMENTI INDICATO. LA LINEA CORTA INDICA IL NUMERO DEI CONDUTTORI DI FASE DA 2,5 mmq, LA

LINEA LUNGA INDICA IL NUMERO DEI CONDUTTORI DI NEUTRO DA

2,5 mmq. LE LINEE NON SONO INDICATE SE SONO RICHIESTI SOLTANTO DUE CONDUTTORI DA 2,5 mmq. O QUANDO

L'INFORMAZIONE SUI CONDUTTORI E' NOTA. I CONDUTTORI DI

TERRA SONO RICHIESTI MA NON MOSTRATI.

MOSTRATI.

1LR1-1

CONDUIT AND CONDUCTORS

2 2

2 2

CONDUIT AND WIRE SIZE CODE

POWER DISTRIBUTION

HOMERUN TO PANELBOARD. SUBSCRIPT INDICATES PANEL DESIGNATION

AND CIRCUIT NUMBERS. ALL HOME RUNS ARE 2x2.5mm + 1x2.5mm

GND/16 UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE

THE NUMBER OF 2.5mm PHASE CONDUCTORS, LONG TICK MARKS INDICATE THE NUMBER OF 2.5mm NEUTRAL CONDUCTORS. TICK MARKS NOT SHOWN WHEN ONLY TWO 2.5mm CONDUCTORS ARE

REQUIRED OR WHEN CONDUCTOR INFORMATION IS NOTED. GROUNDING

CONDUCTORS ARE REQUIRED BUT NOT SHOWN.

2x2.5mm + 1x2.5mm GND/16 WHERE NO TICK MARKS ARE SHOWN, UNLESS OTHERWISE INDICATED. LONG TICK MARKS INDICATE THE

NUMBER OF 2.5mm NEUTRAL CONDUCTORS, SHORT TICK MARKS INDICATED THE NUMBER OF 2.5mm PHASE CONDUCTORS. GROUND

CONDUCTOR REQUIRED BUT NOT SHOWN, UNLESS OTHERWISE

INDICATED.

CONDUCTOR

ALL CABLES ARE SINGLE

PARALLEL FEEDERS

SIZE (mm )2

CONDUCTOR

NUMBER OF

(2) 3x95 + 1x70 GND/80

NOTE:

NUMBER OF SINGLE

CONDUCTORS

CONDUIT SIZE (mm)

PANELBOARD, SURFACE MOUNTED.

T

VFD

M

CONNESSIONE AL MOTORE. IL NUMERO INDICA LA POTENZA IN KW.

TRASFORMATORE A SECCO.

AVVIATORE A FREQUENZA VARIABILE. VEDERE TABELLA AVVIATORI A FREQUENZA VARIABILE

SUI FOGLI EP702

INDICATO SULLE PLANIMATRIE INGRANDITE DEI LOCALI.

SBARRA DI TERRA, VEDRE A3/EP503 PER IL PARTICOLARE. ALTEZZA DI MONTAGGIO COME

GROUND BUS, SEE A3/EP503 FOR DETAIL. MOUNTING HEIGHT AS INDICATED

VARIABLE FREQUENCY DRIVE. SEE VARIABLE FREQUENCY DRIVE SCHEDULE

DRY TYPE TRANSFORMER.

ON ENLARGED ELECTRICAL ROOM PLANS.

CONNECTION TO MOTOR, NUMERAL INDICATES KW RATING.

ON SHEET EP702

ONE 220V CIRCUIT PLUS ONE 120V CIRCUIT. UNLESS OTHERWISE

INDICATED EACH CIRCUIT SHALL BE 2x2.5mm + 1x2.5mm GND/16.

UN CIRCUITO A 220V, PIU UN CIRCUITO A 120V. SE NON ALTRIMENTI

INDICATO, OGNI CIRCUITO DOVRA' ESSERE 2x2,5mmq + 1x2,5mmq T/16.

GRAP GENERATOR REMOTE ANNUNCIATOR PANEL. MOUNT AT 1.8m ABOVE FINISHED FLOOR TO TOP OF PANEL QUADRETTO ALLARMI A DISTANZA DEL GENERATORE. MONTARE A 1.8m DALLA PARTE SUPERIORE IN ASSE

COL PAVIMENTO.

CEILING/WALL SENSORS

CEILING MOUNTED LINE VOLTAGE OCCUPANCY SENSOR. SEE D1/EL601 FOR

WIRING DIAGRAMS.

a 1

U

SWITCH LEG BEING CONTROLLED.

PATTERN TYPE. SEE SCHEDULE BELOW.

SENSOR ORIENTATION

TECHNOLOGY TYPE. SEE SCHEDULE BELOW.

WALL SWITCHES

OCCUPANCY SENSING WALL SWITCH WITH MANUAL OVERRIDE. MOUNT AT 1.2m

AFF TO CENTER.

L U

TECHNOLOGY TYPE. SEE SCHEDULE BELOW.

LOW VOLTAGE SENSOR.

TECHNOLOGY TYPE SCHEDULE:/

U ULTRASONIC/

R INFRARED/

D DUAL TECHNOLOGY(INFRARED & ULTRASONIC)/

PATTERN TYPE SCHEDULE:/

1 10' x 90' 2 20' x 20' 3 30' x 30' 4 40' x 40'

5 500 SQFT

6 1000 SQFT

7 1200 SQFT

OCCUPANCY SENSORS

SENSORE DI PRESENZA A TENSIONE DI RETE PER MONTAGGIO A SOFFITTO.

PER SCHEMA DI CABLAGGIO VEDERE DISEGNO D1/EL601.

COLLEGAMENTO DI COMANDO

TIPO DI ARTICOLO. VEDERE TABELLA SOTTOSTANTE

ORIENTAMENTO DEL SENSORE

TIPO DI TECNOLOGIA. VEDERE TABELLA SOTTOSTANTE

SENSORE DI PRESENZA. TUTTI GLI INTERRUTTORI DEVONO AVERE UN BY-

PASS MANUALE. MONTARE A 1.2 m IN ASSE SUL PAVIMENTO FINITO.

INTERRUTTORI A PARETE

RILEVATORI DI PRESENZA

RILEVATORI A PARETE/SOFFITTO

TIPO DI TECNOLOGIA. VEDERE TABELLA SOTTOSTANTEITO.

SENSORE A BASSA TENSIONE.

TABELLA ARTICOLI

TABELLA TIPI DI TECNOLOGIA

ULTRASUONI

INFRAROSSI

TECNOLOGIA DUALE INFRAROSSI/ULTRASUONI

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 1

EL

EC

TR

IC

AL

LE

GE

ND

EG003

CA

DRS SAE KLM

LE

GE

ND

A

EL

ET

TR

IC

O

14024871

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

610mm BELOW FINISHED GRADE.

100mm DEEP UNLESS OTHERWISE NOTED. SEE A2/ET502 FOR SUPPORT DETAIL.

DN

G

TV

E1

ST

E

J

C

M

C

CTX-X

XX

X

H

A O

R

G

OC

SCATOLA DI DERIVAZIONE O DI TIRO.

COLLEGAMENTI APPARECCHIATURE

LE ALTEZZE DI MONTAGGIO SONO IN MILLIMETRI.

INDICA L'ALTEZZA DI MONTAGGIO SOPRA IL PAVIMENTO FINITO.

IMPIANTO TELEVISIVO

AMPLIFICATORE CON DATI NOMINALI.

CAVO TELEVISIVO PER PARTITORE DI SEGNALE.

CONTATTO NORMALMENTE APERTO (N.O.)

BOBINA DI AZIONAMENTO.

FUSIBILE CIRCUITO DI CONTROLLO

CONTATTO NORMALMENTE CHIUSO (N.C.).

CONTATTORE AVVIAMENTO MOTORE

CONTATTO RELE' DI SOVRACCARICO

SELETTORE A 3 POSIZIONI AUTOMATICO-MANUALE-ESCLUSO

CIRCUITO DI COMANDO SE NON INDICATO DIVERSAMENTE.

BOBINA CON SGANCIO. LA TENSIONE DOVRA' ESSERE DELLO STESSO TIPO DEL

SIMBOLI SCHEMI DI CONTROLLO

TERMINALE DI LINEA.

ARMADIO TELEFONICO IN COMPENSATO.

SPIA ROSSA

SPIA VERDE

IMPIANTO STRUTTURATO PER CAVI E PERCORSI

CONDUTTORE DISCENDENTE PER IMPIANTO PARAFULMINI.

DISPERSORE(I).

CONNESSIONE A T.

CAVO PER PRESA TELEVISIVA. VEDERE A1/EP503 PER PARTICOLARE. MONTARE

A PARETE A 300mm SOTTO IL SOFFITTO FINITO IN ASSE SE NON DIVERSAMENTE

DISPOSITIVO MULTIPRESA DIREZIONALE PER COLLEGAMENTO AL CAVO TV.

"CTX-X" INDICA LA PRESA DESIGNATA. VEDERE D2/ET502 PER IL PARTICOLARE DEL

COLLEGAMENTO AI TERMINALI DELL'APPARECCHIATURA, ALLE STRISCE

ACCESSORI, ECC. NECESSARI PER UN CORRETTO COLLEGAMENTO. LE

TUBI FLESSIBILI, I CONNETTORI DELLE SCATOLE DI DERIVAZIONE, GLI

VEDERE TABELLA COLLEGAMENTO APPARECCHIATURE SUI FOGLI EP701.

TERMINALI O AL QUADRO COMPRESI TUTTI I CONDUTTORI, I TUBI, I

SCRITTE INDICANO IL NUMERO DI COLLEGAMENTO DELL'APPARECCHIATURA.

PRESA TELEFONICA A PARETE. VEDEREC1/ET501 PER LA CONFIGURAZIONE DELLE PRESE.

MONTARE A 1,4 m IN ASSE SUL PAVIMENTO FINITO SE NON ALTRIMENTI INDICATO.

PRESA COMBINATA VOCE/DATI MONTATA CON ASSE A 100mm SOPRA AL BANCONE O AL PARASPRUZZI, QUALE SIA PIU’ ALTO. PER LA CONFIGURAZIONE DELLA PRESA VEDI C1/ET501.

COMBINAZIONE PRESA FONIA/DATI. VEDERE C1/ET501 PER LA CONFIGURAZIONE DELLE PRESE.

MONTARE A 457 mm IN ASSE SUL PAVIMENTO FINITO SE NON ALTRIMENTI INDICATO.

COMBINAZIONE PRESA FONIA/DATI MONTATA IN SCATOLA INCASSATA. VEDI PARTICOLARE C4/EP503

SBARRA DI TERRA PER TELECOMUNICAZIONI. MONTARE A 460mm SOPRA IL PAVIMENTO FINITO IN ASSE.

VEDI PARTICOLARE A1/ET501.

INDICATO.

SBARRA PRINCIPALE DI TERRA PER TELECOMUNICAZIONI. MONTARE A 460mm SOPRA IL PAVIMENTO FINITO

IN ASSE. VEDI PARTICOLARE A4/ET501.

CANALINA PER I SOLI CAVI A BASSA TENSIONE PER IL CABLAGGIO DEGLI IMPIANTI DI COMUNICAZIONE, LARGA 300mm E PROFONDA 100mm SALVO DIVERSA ANNOTAZIONE. VEDI PARTICOLARE A2/ET502

CONDUTTORE SUL TETTO PER IMPIANTO PARAFULMINI.

IMPIANTO PARAFULMINI

CONDUTTORE ANELLO DI TERRA IMPIANTO PARAFULMINE A 610mm

AL DI SOTTO DEL PIANO DI CAMPAGNA.

DISPOSITIVO DI ATTACCO LINEA.

JUNCTION BOX OR PULL BOX.

EQUIPMENT CONNECTIONS

TELEVISION SYSTEM

AT 300mm BELOW FINISHED CEILING TO CENTER UNLESS OTHERWISE NOTED.

CABLE TELEVISION OUTLET. SEE A1/EP503 FOR DETAIL. WALL MOUNT

AMPLIFIER WITH RATING.

CABLE TELEVISION CABLE SPLITTER.

CABLE TELEVISION DIRECTIONAL MULTI-TAP DEVICE. "CTX-X" INDICATES TAP

NORMALLY CLOSED CONTACT (N.C.)

NORMALLY OPEN CONTACT (N.O.)

CONTROL CIRCUIT FUSE

OVERLOAD RELAY CONTACT.

MOTOR STARTER COIL.

3 POSITION HAND-OFF-AUTOMATIC SELECTOR SWITCH

SHUNT TRIP OPERATING COIL. VOLTAGE SHALL BE THE SAME AS CONTROL

CIRCUIT VOLTAGE, UNLESS OTHERWISE INDICATED.

LINE TERMINATOR.

DESIGNATION. SEE D2/ET502 FOR LINE TAP DEVICE DETAIL.

RED PILOT LIGHT

TELECOMMUNICATIONS GROUND BUS BAR. MOUNT AT 460mm ABOVE FINISHED FLOOR TO

1.4m ABOVE FINISHED FLOOR TO CENTER UNLESS OTHERWISE NOTED.

WALL MOUNTED TELEPHONE OUTLET. SEE C1/ET501 FOR OUTLET CONFIGURATION. MOUNT

COMBINATION VOICE/DATA OUTLET MOUNTED 100mm ABOVE COUNTER OR BACKSPLASH, WHICHEVER

IS HIGHER TOP TO CENTER. SEE C1/ET501 FOR OUTLET CONFIGURATION.

CENTER. SEE DETAIL A1/ET501.

PLYWOOD TELEPHONE BACKBOARD.

TGB O.L.

GREEN PILOT LIGHT

457mm ABOVE FINISHED FLOOR TO CENTER UNLESS OTHERWISE NOTED.

COMBINATION VOICE/DATA OUTLET. SEE C1/ET501 FOR OUTLET CONFIGURATION. MOUNT

AND PATHWAY SYSTEM

STRUCTURED CABLING

OPERATING COIL

LIGHTNING PROTECTION SYSTEM DOWN CONDUCTOR.

TEE CONNECTION.

GROUND ROD(S).

LIGHTNING PROTECTION SYSTEM

LIGHTNING PROTECTION SYSTEM GROUND LOOP CONDUCTOR AT

LOW VOLTAGE CABLE TRAY FOR COMMUNICATIONS SYSTEMS WIRING ONLY, 300mm WIDE BY

TELECOMMUNICATIONS MAIN GROUND BUS BAR. MOUNT AT 460mm ABOVE FINISHED FLOOR TO

CENTER. SEE DETAIL A4/ET501.

TMGB

LIGHTNING PROTECTION SYSTEM ROOF CONDUCTOR.

COMBINATION VOICE/DATA OUTLET MOUNTED IN RECESSED FLOOR BOX. SEE DETAIL C4/EP503.

CONNECTION TO EQUIPMENT LEADS, TERMINAL STRIPS OR CONTROL PANEL INCLUDING

ALL CONDUCTORS, CONDUIT, FLEXIBLE CONDUIT, JUNCTIONS BOXES CONNECTORS,

FITTINGS, ETC. REQUIRED FOR PROPER CONNECTION. SUBSCRIPT INDICATES

EQUIPMENT CONNECTION NUMBER, SEE EQUIPMENT CONNECTION SCHEDULE ON SHEET EP701.

MOUNTING HEIGHT IS IN MILLIMETERS.

INDICATES MOUNTING HEIGHT ABOVE FINISHED FLOOR.

CONTROL DIAGRAM SYMBOLS

+457

LOW VOLTAGE LADDER RACK FOR COMMUNICATIONS SYSTEMS WIRING ONLY, 500mm WIDE. SEE C2/ET502 FOR

SUPPORT DETAIL

PASSERELLA A SCALETTA A BASSA TENSIONE PER IMPIANTI DI CABLAGGIO SOLO PER TELECOMUNICAZIONI. LAR.

500 mm. VEDI PARTICOLARE C2/ET502

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 1

EL

EC

TR

IC

AL

LE

GE

ND

EG004

CA

DRS SAE KLM

LE

GE

ND

A

EL

ET

TR

IC

O

14024872

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

C M

H

C M

H

C M

H

CMH631

CMH632

CMH633

UT

U T

UT

U T

UT

CMH634

CMH635

CMH636

CMH637

CMH638

CMH640

C M

H

C M

H

CMH 639

CMH 329

UL

UL

UL

UL

UL

UL

UL

U L

U L

UL

UL

U L

UL

U L

U L

UL

UL

UL

U L

U L

U L

UL

U L

UL

U L

UL

UL

U L

UL

UL

UL

UL

UL

U L

U L

U L

U L

UL

UL

U L

LV

LV

U L

UL

UL

UL

UL

UL

UP

UP

UP

UP

UP

UP

UP

UP

US

US

US

US

US

US

US

US

US

U S

U P

U P

U P

U P

UP

UP

D OW N

M M

M

M

M

M

PIG RECEIVER

JP5-150-CS

JP5-150-CS

PIG LAUNCHER

JP

5-

0-

CS

JP

5-

0-

CS

JP5-300-CS

JP5-200-CS

JP5-150-CS

JP

5-

0-

CS

JP

5-

0-

CS

JP5-300-CS

JP

5-

0-

CS

JP5-300-CS

JP5-200-SS

JP5-200-CS

JP5-200-CS

JP

5-

0-

SS

JP

5-

0-

CS

TT

TT

D OW N

M M

M

M

M

M

PIG RECEIVER

JP5-150-CS

JP5-150-CS

PIG LAUNCHER

JP

5-

0-

CS

JP

5-

0-

CS

JP5-300-CS

JP5-200-CS

JP5-150-CS

JP

5-

0-

CS

JP

5-

0-

CS

JP5-300-CS

JP

5-

0-

CS

JP5-300-CS

JP5-200-SS

JP5-200-CS

JP5-200-CS

JP

5-

0-

SS

JP

5-

0-

CS

VALVOLA D'IRRIGAZIONE

TT

TT

200∅ SAN.

SA

N S 1%

150∅ SAN.

FM.

SA

N

∅ S

AN

. F M.

200∅ SAN.S=0.5%

S=0.5%

CURVA A 45° - 150∅CON BLOCCO REGGISPINTA

65∅ W

200∅ F.W

250∅ F.W

200∅ W.

150∅ F.W.

80∅ W.

S A N

200∅ SAN.

S A N S 1%

THRUST BLOCK

150∅ 45° BEND W/

200∅ W

150∅ W.

200∅ SAN.

S A N S 1%

S A N

200∅ SAN.

200∅ SAN.

200∅ SAN.

200∅ SAN.

150∅ W.

200∅ W.

D

200∅ W

L

200∅ W.

150∅ SAN.

FM.

65∅ W .250∅ F.W.

250∅ F.W.

200∅ W.

S D

S D

S D

S D

S .7

SD

S D

S .0

S D

SD ∅375

SD ∅375 S=0.7%

S D

S

S D

S D

S D

S D

SD ∅ 300

S D

S D

SD ∅ 300

S D

S D

S D

S D

SD ∅ 300

SD ∅ 300

SD ∅ 600

SD ∅ 600

SD ∅ 300

SD ∅ 375

SD ∅ 300

SD ∅ 375

S D

S D

SD ∅300

S D

SD ∅300

S D

S D

S D

S D

5S D

S D

S

SD ∅375

SD ∅375

SD

S D

S A N

113°

4.50

∅ S

AN.

FM

IE=22.05

USCITA

200∅ SAN.

S=0.5% S=0.5%

S=0.5%

S=0.5%

WADY

WADY

T

T

10211011

1014 1015

1016 1017

S

ES101

ES103

ES102

ES104

ES105 ES106

ES107

SATCOM FACILITY

DRMO

HAZMAT

FUEL FARM

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 2000

CO

MP

OS

IT

E

SI

TE

P

LA

N

ES100

CA

DRS SAE KLM

PI

AN

TA

C

OM

PO

SI

TA

14024873

N TRUE

NORTH

100000

1:2000 GRAPHIC SCALE (MILLIMETERS)

50000 2000000

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

SA

TC

OM

F

AC

ILI

TY

FF

.87

GUARDHOUSE

FF =24.600SA

TC

OM

F

AC

ILI

TY

FF

.87

SA

TC

OM

F

AC

ILI

TY

FF

.87

SA

TC

OM

F

AC

ILI

TY

FF

.87

M

- 1

SS

50M - 200� SS

61M - 200� SS

M

- 1

SS

M

- 1

SS

62M - 200� SS

SS MH SS MH 35 SS MH 4

SCO

INV=21.989

SCO

INV=21.791SCO

INV=23.805

300� SD

300� SD 300� SD

300� SD

300� SD

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

400� SD

0�

S D

400� SD

0�

S D

200� SD

200� SD

200� SD

200� SD

200� SD

200� SD

0�

S D

0�

S D

SD

200�

200� SD

200� SD 200� SD

200� SD

300� SD

200� SD 200� SD

DI 105 DI 106 DI 302

DI 104

DI 103

DI 101

DI 301

DI 102

EW 107 EW 303

DI 203

DI 202

DI 201

EW 204

DI 407

DI 405

DI 404

DI 402

EW 408

DI 406

DI 403

DI 401

DI 502

DI 500

EW 503

FES 605

FES 601

FES 60

FES 606

FES 607

FES 608

DI 100

DI 501

FH

FH

WM

WM

FH

W

0 �

W

0 � W

150 � W

150 � W

0 �

F W

PI

V

0 �

W

150 � W 150 � W

0�

W

150 � FW

150 � W

W

150 � W

150 � FW

W

CMH640

UL

UL

UL

UP

UP

CURVA A 45°

CON BLOCCO REG

S D m m

S D

B

LD

G

F

IR

E

P U M P

H O U S E

S

TY

C O N C

F F .6

N

°3 '3 E

.6 m

E

EE

PHM108S

PMH1

PMH3

CMH105

CMH203

CMH201

CMH202

CMH102

CMH101

EUP

UP

UP

UP

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

UC

ES401

B1

ES402

A1

CMH103

ES501

A3

R1

R3

R5

P1

R2

R4

R6

P2

R7

R9

R11

P3

R8

R10

R12

P4

CMH104

SATCOM

FACILITY

GUARD

HOUSE

ES501

D2

ES501

A1

27 26

US

ES501

B1

ES501

D2

ES501

D2

RADOME/SATELLITE PAD

(TYPICAL FOR 12)

SS1

ES501

A3

ES501

A3

ES501

A1

ES501

A1ES501

A1

PAD FOR PORTABLE/FUTURE

SATELLITE (TYPICAL FOR 4)

ES501

A1

ES403

A3

ES501

A1

ES501

A1

ES501

A3

2828ES501

D2

REF LINE

ES103

RE

F

LIN

E

ES

RE

F

LIN

E

ES

REF LINE

ES103

PHH-501

CHH-1

US

UC

ES501

D1

FC

S

UC

UC

CMH205

UCCMH204

SWITCH STATION 1SWITCH STATION 2

PMH2

UP

1 ES501

D2

1 111

ES501

A1

F1 F2 F3 F4

SPACE FOR FUTURE

RADOME/SATELLITE PAD

(TYPICAL FOR 4)

PEDANA ANTENNA

SATELLITARE RADOME

(TIP. PER 12)

SPAZIO PEDANA

SATELLITARE RADOME

FUTURA (TIP. PER 4)

SPAZIO PEDANA ANTENNA

SATELLITARE RADOME

FUTURA (TIP. PER 4)

SOTTOSTAZIONE DI

SEZIONAMENTO 1

SOTTOSTAZIONE DI

SEZIONAMENTO 2

FCS

ES403

A1

ES501

D2

ES501

D2

ES501

D2

ES403

A4

UP UP

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES101

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024874

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000 N TRUE

NORTH

1 ENGINE GENERATOR SET

2 FUTURE ENGINE GENERATOR SET

3 FUEL CELL (BID OPTION).

4 CHILLER CH/1 TOWER (BASE BID).

5 COOLING TOWER (BID OPTION).

6 NOT USED.

7 PROVIDE CONDUCTORS IN EXISTING SPARE 140mm CONDUIT.

8 TO SWBD-UPS2, SEE C1/EP401 FOR LOCATION.

9 TO ESSWBD, SEE C1/EP401 FOR LOCATION.

10 TO EMSWBD, SEE C1/EP401 FOR LOCATION.

11 ONE CONDUIT WITH FEEDER SERVING PANEL EL8 SHALL BE

TERMINATED AT SWBD-UPS-1, SEE C1/EP401 FOR LOCATION

NOTES:

SHEET NOTES:

KEY NOTES:

A. SEE SHEET ES108 FOR SITE LIGHTING PLAN.

B. SEE SHEETS EP402 AND ET401 FOR GUARD HOUSE PLANS.

NOTE:

NOTE DEL FOGLIO:

A. PER LA PIANTA DELL'ILLUMINAZIONE DELL'AREA VEDERE FOGLIO

ES108.

B. PER LA PIANTA DELLA GUARDHOUSE VEDERE FOGLI EP402 E

ET401.

NOTE DI RIFERIMENTO:

1. GRUPPO GENERATORE DIESEL.

2. GRUPPO GENERATORE DIESEL FUTURO.

3. CELLA A COMBUSTIBILE.

4. TORRE GRUPPO FRIGO CH/1 (OFFERTA DI BASE)

5. TORRE DI RAFFREDDAMENTO (OPZIONE DI OFFERTA)

6. NON USATO.

7. PROVVEDERE CONDUTTORI NEL TUBO DA 140 mm DI RISERVA.

8. AL QUADRO WWBD-UPS2, PER L’UBICAZIONE VEDI C1/EP401.

9. AL QUADRO ESSWBD, PER L’UBICAZIONE VEDI C1/EP401.

10. AL QUADRO EMSWBD, PER L’UBICAZIONE VEDI C1/EP401.

11. UN TUBO CON CAVO ALIMENTAZIONE QUADRO EL8 SARA’

TERMINATO A SWBD-UPS1, PER L’UBICAZIONE VEDI C1/EP401.

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U

R S

C H

AN

G

ES

J U

L

35M - 200� SS

SS MH 2

600� SD

FES 603

FES 604

0 �

W

0 � W

C M

H

C M

H

CMH631

CMH632

CMH633

CMH634

CMH635

CMH636

CMH637

CMH638

CMH 639

UL

UL

UL

UL

U L

U L

UL

UL

U L

UL

U L

U L

U L

UL

UL

UL

UL

UL

UL

UL

UL

P

UP

UP

UP

UP

UP

UP

US

US

US

US

US

US

U S

U P

U P

U P

UP

200∅ SAN.

S A N S 1%

150∅ SAN.

FM.

S A N

∅ S

AN.

FM

200∅ SAN.S=0.5%

S=0.5%

- 150∅

GGISPINTA

65∅ W 200∅

250∅ F.W

200∅ W.

150∅ F.W.

80∅ W.

S A N

200∅ SAN.

S A N S 1%

THRUST BLOCK

150∅ 45° BEND W/

200∅ W

150∅ W.

200∅ SAN.

S A N S 1%

S A N

200∅ SAN.

200∅ SAN.

200∅ SAN.

200∅ SAN.

150∅ W.

200∅ W.

D

200∅ W

L

200∅ W.

150∅ SAN

. FM.

S D

S

S D

S .7

S

S D

S

S D

SD ∅300

S D

SD ∅300

S D

S D

S D

S D

SD ∅375

S D

S A N

113°

4.50

∅ S

AN.

FM

IE=22.05

USCITA

200∅ SAN.

S=0.5% S=0.5%

S=0.5%

S=0.5%

WADY

S m

C

LF

W

B A R B E D

W

IR

E

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS

GRASS IRVIRV

IRV

IRV

IRV

IRV

IRV IRV

IRV

IRV

WV

WV WV

WV

m m

F W

(P E R

P

LA

N

250mm FW

(PER PLAN)

250m m

FW

(PER

PLAN)

m m

W

(P E R

P

LA

N

200mm W

(PER

PLAN)

200mm W

(PER

PLAN)

150mm W

(PER

PLAN)

150mm W

(PER

PLAN)

150mm W 150mm FW80mm W m m

S D6 m m

S D

0m m

SD

m m

S D

300mm

SD

m m

S D

LIFT

FOR

EQUIP

SCO

FM

100m m

SS

m m

S S m m

S S

200mm SS m m

S S

200mm SS

200mm SS

200mm

SS

200mm

SS CONTROL

BOXU

C

UC

UC

UC

U C

U C

U C

U C

UC

0m m m m m m m m m m m m

0m m m m m m m m50 m m

0m m m m m m m m m m m m

CONC

CONC

C O N C

C O N C

CONC

CONC

CONC

CONC

SIGN

TOB

TOB

TOB

TOB

BUS STOP

SWITCHGEAR

CONC BLDG

FF=24.845

BLDG #1020

FF=24.694

SWITCHGEAR

S 85°36'57" E 74.731m

S

°1 '5 W

.9 m

TR 3 MAG

NAIL(S)

N 4138987.67 E 2511609.81

TR 2 MAG NAIL(S)N 4139032.47

E 2511612.97

TR 1 MAG NAIL(S)N 4139038.18

E 2511538.46

TBM 1

MHFF7

CMH231

MHFF6

EUP

EUP

EUC

PMH101S

CMH631

PHM102S

CMH632

PHM103S

PHM105S

CMH636

PHM104S

CMH634

CMH635

PHM106S

CMH637

PHM107S

CMH636

CMH633

EU

P

EU

C

EU

P

EU

C

EUP

EUPEUC

EUC

EUP EUC

EUP

EUP

EUP

EUP

EUP

EUC

EUC

EUC

EUC

REF LINE

ES104

REF LINE

ES104

EUP

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES102

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024875

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

1 CONNECT PRIMARY FEEDER TO SPARE SWITCH

POSITION IN EXISTING PAD MOUNTED SWITCH 693.

2 EXISTING PAD MOUNTED SWITCH 693.

3 EXISTING SUBSTATION 1019.

4 SPARE SWITCH POSITION CURRENTLY HAS

ABANDONED CABLE CONNECTED TO IT. ABANDONED

CABLE IS CAPPED IN EXISTING MANHOLE PMH1065.

DISCONNECT AND COMPLETELY REMOVE CABLE

PRIOR TO INSTALLING NEW PRIMARY FEEDER.

COORDINATE SPARE SWITCH POSITION WITH THE

CONTRACTING OFFICER.

5 PROVIDE CONDUTORS IN EXISTING SPARE 140mm

CONDUIT.

NOTES:

KEY NOTES:

NOTES:

NOTE DI RIFERIMENTO:

1. COLLEGARE IL FEEDERE PRIMARIO AL SEZIONATORE DI

RISERVA DEL QUADRO DI SEZIONAMENTO SU PEDANA

ESISTENTE 693.

2. QUADRO DI SEZIONAMENTO SU PEDANA ESISTENTE 693.

3. CABINA ESISTENTE 1019.

4. IL CAVO COLLEGATO ALL'INTERRUTTORE DI RISERVA E'

ATTUALMENTE ABBONDANATO E LA SUA ESTREMITA'

NEL POZZETTO ESISTENTE PMH1065 E' NASTRATA.

SCOLLEGARE E RIMUOVERE COMPLETAMENTE IL CAVO

PRIMA DELL'INSTALLAZIONE DEL NUOVO CAVO DI

ALIMENTAZIONE PRIMARIA. COORDINARE LA POSIZIONE

DELL'INTERRUTORE DI RISERVA CON L'UFFICIALE

CONTRAENTE.

5. PROVVEDERE CONDUTTORI NEL TUBO DA 140 mm DI

RISERVA.

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

US

T

T

.5 m

C

LF

W

B A R B E D

W

IR

E

BRUSH

WV

WV

IRV

IRV

150mm

(PER

PLAN)

m m

S D m m

S D m m

S D m m

S D

380mm

SD

CENTRO DI MANUTENZIONEVIA FLORIO, 21MISTERBIANCO (CT) TEL095/471 444

CENTRO DI MANUTENZIONEVIA FLORIO, 21MISTERBIANCO (CT) TEL095/471 444

GAS MAIN

GAS MAIN

GAS MAIN

G A S

M A

IN

0m m

0m m

0m m

BAMBOO

PATCH

CONC

CONC

CONC

2.1m PERIMETER FENCE W/

CONSTANTINE & 6 BARBED WIRE

2.1m PERIMETER FENCE W/CONSTANTINE & 6 BARBED WIRE

TOB

TOB

TOB

TOB

TOB

TOB

TO

B

B

LD

G

P U M P

H O U S E

S

TY

C O N C

F F .7

S

°3 '4 E

.7 m

TR 4 MAG NAIL(S)N 4138907.49

E 2511489.39

TR 5 MAG NAIL(S)N 4138809.07

E 2511505.75

TBM 2

CMH207

UC

ES501

A1

REF LINE

ES101

REF LINE

ES101

RE

F

LIN

E

ES

RE

F

LIN

E

ES

CMH206

UC

UC

ES501

A1

ES501

A1

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES103

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024876

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U

R S

C H

AN

G

ES

J U

L

U L

UL

UL

UL

U L

U L

UL

U L

UL

UL

U L

UL

UL

UL

UL

UL

U L

U L

U L

U L

U L

LV

LV

U L

US

US

S

W . F.W

65∅ W .250∅ F.W.

250∅ F.W.

200∅ W.

S D

S D

0S D ∅ 3

S D

S .0

S D

SD ∅375

SD ∅375 S=0.7%

S D

S D

S D

SD ∅ 300

S D

S D

SD ∅ 300

S D

S D

S D

S D

SD ∅ 300

SD ∅ 300

SD ∅ 600

SD ∅ 600

SD ∅ 300

SD ∅ 375

SD ∅ 300

SD ∅ 375

S D

S D

S D

S

SD ∅375

S D

WADY

1014 1015

1016 1017

.5

2.5m CLF W/ 3 BARBED WIRE

2.5m CLF W/ 3 BARBED WIRE

2.5m CLF W/ 3 BARBED WIRE

BRUSH

BRUSH

BRUSH

BRUSH

BRUSH

BRUSH

BRUSH

WV

WV

WV

W

200mm W

(PER PLAN)

250mm FW

(PER PLAN)

250mm W

(PER

PLAN)

380m m

SD

m m

S D m m

S D m m

S D

SCO

UC

U C

0m m

0m m

0m m

0m m

0m m

0m m

0m m

0m m

0m m

0m m m m

0m m

C O N C

2.1m PERIMETER FENCE W/CONSTANTINE & 6 BARBED WIRE

2.1m PERIMETER FENCE W/CONSTANTINE & 6 BARBED WIRE

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

SWITCHGEAR

BLDG #1019

S 86°20'45" E 302.341m

TR 6 MAG

NAIL(S)

N 4138789.80 E 2511807.47

TBM 3

CMH638

CMH208

CMH209

CMH210

UC

UC

UC

ES501

A1

ES501

A1

ES501

A1

RE

F

LIN

E

ES

RE

F

LIN

E

ES

REF LINE

ES102

REF LINE

ES102

RE

F

LIN

E

ES

UC

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES104

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024877

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U

R S

C H

AN

G

ES

J U

L

UT

UT

U T

DOWN

M M

M

M

M

M

PIG RECEIVER

JP5-150-CS

JP

5-2

-C

S JP

5-3

-C

S

JP5-300-CS

JP5-200-CS

JP5-150-CS

JP

5-1

-C

S

JP

5-2

-C

S

JP5-300-CS

JP

5-2

-C

S

JP5-300-CS

JP5-200-SS

JP5-200-CS

JP5-200-CS

JP

5-1

-S

S

JP

5-2

-C

S

DOWN

M M

M

M

M

M

PIG RECEIVER

JP5-150-CS

JP

5-2

-C

S JP

5-3

-C

S

JP5-300-CS

JP5-200-CS

JP5-150-CS

JP

5-1

-C

S

JP

5-2

-C

S

JP5-300-CS

JP

5-2

-C

S

JP5-300-CS

JP5-200-SS

JP5-200-CS

JP5-200-CS

JP

5-1

-S

S

JP

5-2

-C

S

10381041

1029 1049

BRUSH

BRUSH

BRUSH

(4) 1.400m x 2.150mBOX CULVERT

380mmSD 38 0m m

SD

2.1m PERIMETER FENCE W/

CONSTANTINE & 6 BARBED WIRE

2.1m PERIMETER FENCE W/

CONSTANTINE & 6 BARBED WIRE

2.1m PERIMETER FENCE W/

CONSTANTINE & 7 BARBED WIRE

2.1m PERIMETER FENCE W/

CONSTANTINE & 7 BARBED WIRE

TOB

TOB

TOB

TOB

TOB

TOB

TO

BTOB

TOB

TO

B

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

TOB

CONC FLUME

N 86°27'13" E

151.860m

S 80°10'21" E272.169m

TR 7 MAG

NAIL(S)

N 4138799.19 E 2511959.04

10501029 1049

DOWN

M M

M

M

M

M

JP5-150-CS

JP

5-2

-C

S JP

5-3

-C

S

JP5-300-CS

JP5-150-CS

JP5-200-CSJP5-300-CS

JP5-200-SS

JP

5-2

-C

S

JP5-200-CS

JP

DOWN

M M

M

M

M

M

JP5-150-CS

JP

5-2

-C

S JP

5-3

-C

S

JP5-300-CS

JP5-150-CS

JP5-200-CSJP5-300-CS

JP5-200-SS

JP

5-2

-C

S

JP5-200-CS

JP

CMH211

CMH212

CMH213

UC

UC

ES501

A1

ES501

A1

RE

F

LIN

E

ES

UC

RE

F

LIN

E

ES

ES501

A1

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES105

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024878

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U

R S

C H

AN

G

ES

J U

L

JP5-150-CS

JP5-150-CS

GRASS

GRASS

BRUSH

BRUSH

510mm SD~

460mm SD~

500m m

SD

(2) 150mm

PVC CONDUIT

.1 m

P E R

IM

E

TE

R

F E N C E

W

C O N S

TA

N

TI

N E

B A R B E D

W

IR

E

TOB

TOB

TOB

TOB TOB

TOB

TOB

TOB

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

TO

B

N

°4 '9 E

.1 m

TR 8 MAG

NAIL(S)

N 4138752.74 E 2512227.22

TBM 4

JP5-150-CS

JP5-150-CS

CMH214

CMH215

UC

UC

ES501

A1

RE

F

LIN

E

ES

REF LINE

ES107

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES106

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024879

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U

R S

C H

AN

G

ES

J U

L

GRASS

GRASS

460mm SD

460mm SD

.1 m

P E R

IM

E

TE

R

F E N C E

W

C O N S

TA

N

TI

N E

B A R B E D

W

IR

E

TO

B

TO

BTO

B

TO

B

TO

BTO

B

TO

B

TO

B

TO

B

TR 9 MAG

NAIL(S)

N 4138942.23 E 2512242.92

CMH1

UC

EU

C

ES501

A1

REF LINE

ES106

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

EL

EC

TR

IC

AL

S

IT

E

PL

AN

ES107

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024880

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U

R S

C H

AN

G

ES

J U

L

SCO

INV=21.989

SCO

INV=21.791SCO

INV=23.805

300� SD

300� SD 300� SD

300� SD

300� SD

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

400� SD

600� SD

0�

S D

400� SD

0�

S D

200� SD

200� SD

200� SD

200� SD

200� SD

200� SD

0�

S D

0�

S D

SD

200�

200� SD

200� SD 200� SD

200� SD

300� SD

200� SD 200� SD

DI 105 DI 106 DI 302

DI 104

DI 103

DI 101

DI 301

DI 102

EW 107 EW 303

DI 203

DI 202

DI 201

EW 204

DI 407

DI 405

DI 404

DI 402

EW 408

DI 406

DI 403

DI 401

DI 502

DI 500

EW 503

FES 603

FES 605

FES 601

FES 602

FES 604

FES 606

FES 607

FES 608

DI 100

DI 501

CMH637

CMH638

CMH640

CMH 639

UL

UL

UL

UL

U L

U L

UP

UP

UP

UP

US

US

U S

CURVA A 45° - 150∅CON BLOCCO REGGISPINTA

250∅ F.W

200∅ W.

150∅ F.W.

80∅ W.

S A N

200∅ SAN.

THRUST BLOCK

150∅ 45° BEND W/

200∅ W

150∅ W.

200∅ SAN.

200∅ SAN.

D

S D

S D

S D

S D

5S D

S D

S=0.5%

S

S1

S3

S3

S3

S3

S3 S3 S3 S3 S3

S1 S1 S1 S1 S1 S1 S1 S1 S1

S3 S3

S1

S1

S1

S3 S3 S3 S3 S3 S3 S3 S3

S2

S3

S3

S3

S1 S1

S1 S1

S1 S1

S1 S1

S2

S2

S2

S2

SATCOM

FACILITY

GUARD

HOUSE

S2

S2

S2

S1

1 1

DUL

DUL

DUL DUL

S1

S1

S1

S1 S1

S1

S1

S1

S3

ES1-2

ES1-3

ES1-4

ES1-5 ES1-6

ES1-7

UL ULULULULULULULUL

UL

UL

UL

UL

UL UL UL UL UL UL UL

UL UL UL UL UL UL UL

UL

UL

UL

UL

UL

UL

UL

UL UL

UL

UL

UL

UL

UL

UL

UL

UL

UL UL UL

UL UL UL UL

UL

UL

UL

HHHHHHHHHHHHHHHHHH HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HHHHHHHHHHHHHH

HHHHHHHHHHHHHHHH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

HH

S1

UL

HH

HHHH

HH

HH

HH

HH

HH

HH

HH

HH

UL

AD L

EK

N

LL

E F

S

R P

O

IS EN

L

GI

O N A

E E

N R

EC NIL

S E

No 0052705

STATE OF

ROLF

I D A

EE

AS

M

ON

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

E

ER

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S E

N G

IN

EE

R

IN

G C

O M

M A

N D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-11-D-1008 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 500

SI

TE

LI

GH

TI

NG

P

LA

N

ES108

CA

DRS SAE KLM

PL

AN

IM

ET

RI

A

EL

ET

TR

IC

A

14024881

25000

1:500 GRAPHIC SCALE (MILLIMETERS)

12500 500000

N TRUE

NORTH

1 REMOVE EXISTING POLE TOP LIGHTING FIXTURE,

POLE, POLE BASE, AND HANDHOLE

2 REMOVE UNDERGROUND LIGHTING CIRCUIT TO NEXT

EXISTING HANDHOLE APPROXIMATEL 20m FROM

LAST DEMOLISHED POLE.

NOTES:

KEY NOTES:

NOTE:

NOTE DI RIFERIMENTO:

1. SMANTELLARE APPARECCHIO ILLUMINANTE, PALO,

BASAMENTO E POZZETTO DI INFILAGGIO.

2. SMANTELLARE IL CIRCUITO LUCE INTERRATO FINO

AL POZZETTO DI INFILAGGIO SUCCESSIVO

ESISTENTE UBICATO A CIRCA 20 m DALL'ULTIMO

PALO SMANTELLATO.

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

SCO

INV=21.791SCO

INV=23.805

300� SD

300� SD 300� SD

300� SD

300� SD

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

0�

S D

400� SD

0�

S D

400� SD

0�

S D

200� SD

200�…

This is the start of the file's text. The full file is on GovTribe.