VALVOLETUBAZIONI
D
GENERAL IDENTIFICATION
FITTINGS
ABBREVIATIONS
PIPING VALVES
PLUMBING SYMBOLS
SPECIALTIES
M
DRAWING REQUIREMENTS. DO NOT PROCEED WITH
TYPICAL PIPE SLEEVE DETAILS.
NON-ACCESSIBLE.
1. REFER TO DIVISION 22 SPECIFICATIONS FOR ALL PIPING
CONSTRUCTION AND INSTALLATION REQUIREMENTS.
3.
2.
SPECIFICATIONS FOR SHOP DRAWING AND COORDINATION
PIPING LOCATIONS SHOWN ARE SCHEMATIC. REFER TO
AND ASSEMBLY DETAILS.
VALVING, ACCESSORIES, EQUIPMENT CONNECTIONS,
REFER TO TYPICAL DETAIL SHEETS FOR ADDITIONAL
4.
5. PROVIDE FIRE RATED SLEEVES FOR PIPING
CONCEALED SPLINE TILE CEILINGS ARE CONSIDERED
SPECIFICATIONS. WOOD, GYPSUM DRYWALL AND
CONTROL DEVICES AND EQUIPMENT. REFER TO
ADJUSTMENT OF ALL CONCEALED VALVES, FLOW
CONSTRUCTION SUBSTRATES FOR MAINTENANCE AND
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE GENERAL
DRAWINGS ARE AVAILABLE AT THE SITE.
INSTALLATION OF PIPING UNTIL APPROVED SHOP
COORDINATE WITH LIFE SAFETY PLANS. REFER TO
PENETRATIONS THROUGH RATED ASSEMBLIES.
NOTES:
SHEET NOTES:
OWW
CA
G
G
RW
RW
SHW
SHWR
B
COMPRESSED AIR PIPING
GAS GAS METER
OIL-WATER SEPARATOR TANK
OWW
WATER HEATERWH
HEATING/VENTILATING/AIR CONDITIONING
I.E. INVERT ELEVATION
INV INVERT
JANITOR'S SINKJS
HVAC
HD
HDPE
HUB DRAIN
HIGH DENSITY POLYETHYLENE
HOT WATER
HOT WATER RETURN
HW
HWR
HB HOSE BIBB
GR GREASE WASTE
GALLONGAL
G GAS
SCHEDULE REFERENCE
EQUIPMENT TYPE
WH
PDI-A
WATER HAMMER ARRESTER SIZE
PLUMBING DRAINAGE INSTITUTE
WATER HAMMER ARRESTER MARK
EQUIPMENT MARK
WC WATER CLOSET
S
UR
SH
URINAL
SINK
SHOWER
ABB
FCO
AFF
AUTO
BFP
CMH
DWG
ECO
ELEC
ELEV
CAP
CONT
FFE
FLR
CO
AC
FLOOR CLEANOUT
FINISHED FLOOR ELEVATION
FLOOR
EXTERIOR CLEANOUT
ELEVATION
CONTINUATION
ELECTRIC
DRAWING
CLEANOUT
CUBIC METERS PER HOUR
CAPACITY
ABOVE FINISHED FLOOR
AUTOMATIC
BACKFLOW PREVENTER
AIR COMPRESSOR
DESCRIPTION
CW COLD WATER
FS FLOOR SINK
FLOOR DRAINFD
AD AREA DRAIN
TEMP TEMPERATURE
DRAIN PIPING
SAFETY RELIEF VALVE
MAX
(N.C.)
(N.O.)
PRESS
REQD
RPM
TP
WCO
WHA
WHY
VTR
W
SQ
RW
PSI
PDI
PB
MIN
WALL CLEAN OUT
WALL HYDRANT
WATER HAMMER ARRESTER
TRAP PRIMER
VENT THROUGH ROOF
WASTE
SQUARE
PLUMBING DRAINAGE INSTITUTE
RAINWATER
POUNDS PER SQUARE INCH
ROTATIONS PER MINUTE
REQUIRED
NORMALLY OPEN
PRESSURE BOOSTER
PRESSURE
NORMALLY CLOSED
MINIMUM
MAXIMUM
SUMP PUMPSP
V VENT
SAN SANITARY
PRV PRESSURE REDUCING VALVE
MX MIXING VALVE
RD ROOF DRAIN
DESCRIPTIONABB
FLOW (IN DIRECTION OF ARROW)
RISE OR DROP
RISER UP (ELBOW)
VENT THROUGH ROOF
RISER DOWN (ELBOW)
STRAINER
FLOOR/EXTERIOR CLEANOUT
UNION
HOSE BIBB
CLEANOUT
CHECK VALVE
GLOBE VALVE
GATE VALVE
MANUAL BALANCING VALVE
GAS PIPING ABOVE GRADE/SLAB
HOT WATER RETURN PIPING
RAINWATER PIPING ABOVE GRADE/SLAB
PLUG VALVE
BALL VALVE
RAINWATER PIPING BELOW GRADE/SLAB
HOT WATER PIPING
COLD WATER PIPING
VENT PIPING
OR
OR
SANITARY OR WASTE PIPING BELOW
SANITARY OR WASTE PIPING ABOVE
GRADE/SLAB
GRADE/SLAB
HOT WATER MIXING VALVE
WALL HYDRANT (FREEZEPROOF)
TRENCH DRAIN
BACKWATER VALVE
FLOOR PENETRATION
FLOOR DRAIN/HUB DRAIN
FLOOR SINK
BRANCH BOTTOM CONNECTION
BRANCH TOP CONNECTION
CAP
PRESSURE REDUCING VALVE
GAS PIPING BELOW GRADE/SLAB
ROOF DRAIN
HUB DRAIN
SEISMIC BRACING
OILY WASTEWATER PIPING BELOW
OILY WASTEWATER
OWS
HORSEPOWERHP
LAVATORYLAV
GD GARBAGE DISPOSAL
SOLAR HOT WATER RETURN PIPING
SOLAR HOT WATER PIPING
NTS NOT TO SCALE
NPT NATIONAL PIPE THREAD
BOOSTED COLD WATER PIPING
GWH GAS WATER HEATER TMV THERMOSTATIC MIXING VALVE
WM WATER METER
ACQUA OLEOSA DI SCARICO
AL DI SOTTO
TUBAZIONE ARIA COMPRESSA
ABBREVIAZIONI
ABBREVIAZ. DESCRIZIONE
SIMBOLI IDRICO-SANITARIO
RACCORDI
SPECIALITA'
AMMORTIZZATORE COLPO D'ARIETE
IDRANTE A PARETE
TAPPO DI ISPEZIONE A PARETE
SCARICO
VENTILAZIONE ATTRAVERSO COPERTURA
VENTILAZIONE
INNESCO SIFONE
TEMPERATURA
QUADRATO
POMPA DI SENTINA
SANITARIO
ACQUA PIOVANA
ROTAZIONI AL MINUTO
RICHIESTO
SCARICO DEL TETTO
VALVOLA RIDUZIONE PRESSIONE
LIBBRE PER POLLICE QUADRO
PRESSIONE
PLUMBING DRAINAGE INSTITUTE
INNALZATORE PRESSIONE
NORMALMENTE APERTO
NORMALMENTE CHIUSO
VALVOLA MISCELATRICE
MINIMO
MASSIMO
TAPPO DI ISPEZIONE A PAVIMENTO/ESTERNO
TAPPO DI ISPEZIONE
TAPPO
GIUNTO
DIRAMAZIONE CON CONNESSIONE IN BASSO
DIRAMAZIONE CON CONNESSIONE IN ALTO
MONTANTE O DISCENDENTE
MONTANTE VERSO L'ALTO (GOMITO)
MONTANTE VERSO IL BASSO (GOMITO)
VALVOLA MISCELATRICE ACQUA CALDA
PILOZZO A PAVIMENTO
SCARICO A PAVIMENTO/SCARICO PRINCIP.
SCARICO CUNICOLO
SCARICO DEL TETTO
SCARICO PRINCIPALE
VENTILAZIONE ATTRAVERSO LA COPERTURA
PORTATA (IN DIREZIONE DELLA FRECCIA)
ATTRAVERSAMENTO PIANO
VALVOLA SICUREZZA
IDRANTE A PARETE (ANTIGELO)
RUBINETTO PORTAGOMMA
VALVOLA RITEGNO
FILTRO
VALVOLA DI RITEGNO
VALVOLA BILANCIAMENTO MANUALE
VALVOLA A GLOBO
VALVOLA RIDUZIONE PRESSIONE
VALVOLA A SARACINESCA
VALVOLA A SFERA
VALVOLA A MASCHIO
TUBAZIONE SCARICO
TUBAZIONE GAS SOTTO TERRENO/SOLETTA
TUBAZIONE GAS SOPRA TERRENO/SOLETTA
TUBAZIONE RICIRCOLO ACQUA CALDA
TUBAZIONE ACQUA CALDA
TUBAZIONE ACQUA FREDDA
TUBAZIONE VENTILAZIONE
TUBAZIONI PLUVIALI SOTTO TERRENO/SOLETTA
TUBAZIONI PLUVIALI SOPRA TERRENO/SOLETTA
TUBAZIONI SANITARIE O SCARICO
TUBAZIONI SANITARIE O SCARICO
SOTTO TERRENO/SOLETTA
SOPRA TERRENO/SOLETTA
CONTROVENTATURA SISMICA
COMPRESSORE D'ARIA
DRENAGGIO BOCCHE DI LUPO
SOPRA PAVIMENTO FINITO
AUTOMATICO
DISCONNETTORE
CAPACITA'
METRI CUBI PER ORA
TAPPO DI ISPEZIONE
CONTINUAZIONE
ACQUA FREDDA
DISEGNO
TAPPO DI ISPEZIONE ESTERNO
ELETTRICO
QUOTA
TAPPO DI ISPEZIONE A PAVIMENTO
PILETTA SCARICO A PAVIMENTO
QUOTA PAVIMENTO FINITO
PAVIMENTO
PILOZZO A PAVIMENTO
DESCRIZIONEABBREVIAZ.
DOCCIA
ORINATOIO
LAVELLO
VASO IGIENICO
IDENTIFICAZIONE
APPARECCHIATURA
PLUMBING DRAINAGE INSTITUTE
COLPO D'ARIETE
IDENTIFICAZIONE AMMORTIZZATORE
COLPO D'ARIETE SECONDO IL
GRANDEZZA AMMORTIZZATORE
IDENTIFICAZIONE GENERALE
RIFERIMENTO TABELLA
TIPO APPARECCHIATURA
GAS
GALLONE
SCARICO GRASSI
RUBINETTO PORTAGOMMA
SCARICO PRINCIPALE
POLIETILENE ALTA DENSITA
RISCALD./VENTIL./ARIA CONDIZIONATA
ACQUA CALDA
RITORNO ACQUA CALDA
PILOZZO DEL RIPOSTIGLIO
FONDO
QUOTA DI FONDO SCALDA ACQUA
SERBATOIO SEPARATORE OLIO/ACQUA
CONTATORE GAS
TUBAZIONE ACQUE DI SCARICO OLEOSE
CAVALLI DI POTENZA
LAVABO
CONTENITORE RIFIUTI
TUBAZIONE RICIRCOLO ACQUA CALDA SOLARE
TUBAZIONE ACQUA CALDA SOLARE
NON IN SCALA
NOTE:
1. FARE RIFERIMENTO ALLE SEZIONI 22 DELLE SPECIFICHE
PER LE PRESCRIZIONI DI COSTRUZIONE E DI INSTALLAZIONE
DELLE TUBAZIONI.
2. FARE RIFERIMENTO ALLE TAVOLE DEI PARTICOLARI TIPICI PER
I PARTICOLARI DI ASSEMBLAGGIO, DI COLLEGAMENTI DI
APPARECCHIATURE, DI ACCESSORI, E DI VALVOLAME.
3.
PROVVEDERE PANNELLI DI ACCESSO NEI SOTTOSTRATI DI
COSTRUZIONE GENERALE NON ACCESSIBILI AI FINI DELLA
MANUTENZIONE E DELLA REGOLAZIONE DI TUTTE LE
APPARECCHIATURE, DEI DISPOSITIVI DI CONTROLLO DI FLUSSO E
DELLE VALVOLE NASCOSTE. FARE RIFERIMENTO ALLE SPECIFICHE.
SONO CONSIDERATI NON ACCESSIBILI TRAMEZZATURE IN LEGNO
E CARTONGESSO E LISTELLI DI ELEMENTI DI SOFFITTO.
PROVVEDERE MANICOTTI RESISTENTI AL FUOCO PER GLI
ATTRAVERSAMENTI DI TUBAZIONI ATTRAVERSO ASSEMBLAGGI
CLASSIFICATI. COORDINARE CON LE PIANTE PER IL PIANO DI
SICUREZZA. FARE RIFERIMENTO AI PARTICOLARI TIPICI DEI
4.
5.
MANICOTTI PER TUBAZIONI.
NOTE DEL FOGLIO:
LA POSIZIONE INDICATA PER LE TUBAZIONI E' SCHEMATICA.
FARE RIFERIMENTO ALLE SPECIFICHE PER LE PRESCRIZIONI PER
I DISEGNI COSTRUTTIVI E PER I DISEGNI DI COORDINAMENTO.
NON PROCEDERE CON L'INSTALLAZIONE DELLE TUBAZIONI FINO
A QUANDO I DISEGNI DI OFFICINA APPROVATI NON SIANO
DISPONIBILI IN CANTIERE.
FILETTATURA NAZIONALE TUBO
TUBAZIONE ACQUA DI PRESS. INNALZATA
SCALDA ACQUA A GAS VALVOLA MISCELATRICE TERMOSTATICA
CONTATORE ACQUA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
S
YM
BO
LS
A N
D A
BB
R
EV
IA
TI
O
N S
PP001
CA
CRF CRF JEB
SI
M
BO
LI
E
AB
BR
EV
IA
ZI
O N
I I D
R
IC
O S
AN
IT
AR
IO
14024787
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A B C E FD
COMM EXTCOMM EXT
SECURE ROOMSECURE ROOM
IT-2 OPSIT-2 OPS
OFFICEOFFICE
CORRCORR
BREAKBREAK
JANJAN
CONFERENCECONFERENCE
CORRCORR
VESTVEST
TLT FTLT F
TLT MTLT M
STORAGE / SHOPSTORAGE / SHOP
HVACHVAC
BOILERBOILER
IT-1 RACK ROOMIT-1 RACK ROOM
CORRCORR
ELECELEC
STORSTOR
CORRCORR
M S
-1
W F-
FD-3
WHY-1
WHY-1
WHY-1
H B
-1
HB-1
65mm
FD-1
C A
CACA
ELEV. =
GROUND LEVEL FINISHED FLOOR
24.875
AC
TMV
ST
EWC-1
S-1
WC-1
WC-2 WC-2
MS-1
SH-1SH-1
FD
-1
FD-2
FD
-1
IMB-1
UR-1UR-2
L-1
L-1
FCO
FD
-1
L-1
L-1
ECO
FD-2
FD
-1
E W
-1
GWH
RP
RP
RP
S H
W
S H
W R
SP
ET
WM
FD-3
FCO
BFP
2-WAY
WHY-1
FCO
G G
BFP
BFP
BFP
BFP
80mm VTR
80mm VTR
80mm VTR
BFP
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
NOTES:
SHEET NOTES:
1. REFER TO DRAWING PP001 FOR GENERAL SHEET NOTES.
KEY NOTES: 00
NOTE:
NOTE DEL FOGLIO:
1. VEDERE IL DISEGNO PP001 PER LE NOTE
GENERALI DEL FOGLIO
NOTE DI RIFERIMENTO: 00
4750 New Broad Street Orlando, FL www.rlfae.com
1 : 100
G R
O U
N D
F
LO
O R
P
LU
M
BI
N G
P
LA
N
SA
TC
O M
F
AC
IL
IT
Y
PP100A
CA
CRF CRF JEB
IM
PI
AN
TO
ID
R
O -S
AN
IT
AR
IO
P
IA
N O
T
ER
R A
- S
AT
C O
M F
AC
IL
IT
Y
14024788
SANITARIO PIANTA PIANO TERRA - SATCOM FACILITY
1 : 100A2 GROUND LEVEL PLUMBING PLAN-SATCOM FACILITY
N
TRUE
NORTH
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
KEY PLAN
A
1 100 mm SANITARY. INVERT ELEVATION -1.07 M.
2 65 mm RPZ BACKFLOW PREVENTER VALVE.
PIPE THE DRAIN FROM THE BACKFLOW TO
THE MOP SINK ON ADJACENT WALL.
3 80 mm VENT UP TO VTR.
4 40 mm NATURAL GAS TO FUEL CELL (BID
OPTION #1). SEE MECHANICAL DRAWING
MP102 AND PP611.
5 CONNECT 15 mm DOMESTIC HW TO
DISHWASHER UNDER COUNTER THROUGH
MILLWORK.
6 15 mm DOMESTIC CW CONNECTION TO CAC
UNIT.
C1
PP501
C4
PP501
A2
PP601
A4
PP503
A1
PP507
A4
PP509
A3
PP502
A3
PP507
B3
PP508
C4
PP503
C1
PP503
A1
PP502
A1
PP505
C1
PP507
A2
PP503
1 SANITARIO DA 100 mm. QUOTA DI FONDO 1.07 m
2 DISCONNETTORE RPZ DA 65 mm. PROVVEDERE
TUBO DI DRENAGGIO DAL DISCONNETTORE AL
LAVASCOPE SULLA PARETE ADIACENTE
3 SFIATO DA 80 mm FINO A VTR
4 GAS NATURALE 40 mm AL FUEL CELL
(OPZIONE D’OFFERTA #1). VEDI I DISEGNI
MP102 E PP611.
5 COLLEGARE HW DOMESTICA 15 mm ALLA
LAVASTOVIGLIE INCASSATA ATTRAVERSO
L’ARREDO.
6 COLLEGARE CW DOMESTICA 15 mm ALLA CAC UNITA.
TYPICAL
TIPICO
B3
PP5086
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
G.1 G.2
G.B
G.A
G.D
L-2WC-2
MS-1
GUARDHOUSE
TLT
JAN
50mm
ECO
ECO
FD-1
BFP
100mm
2-WAY
ET
WHY-1
G.1 G.2
G.B
G.A
G.D
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
NOTES:
SHEET NOTES:
1. REFER TO DRAWING PP001 FOR GENERAL SHEET NOTES.
KEY NOTES: 00
NOTE:
NOTE DEL FOGLIO:
1. VEDERE IL DISEGNO PP001 PER LE NOTE
GENERALI DEL FOGLIO
NOTE DI RIFERIMENTO: 00
4750 New Broad Street Orlando, FL www.rlfae.com
1 : 50
G R
O U
N D
/R O
O F
FL
O
O R
P
LU
M
BI
N G
G
U
AR
D H
O U
SE
PP100B
CA
CRF CRF JEB
IM
PI
AN
TO
ID
R
O -S
AN
IT
AR
IO
P
IA
N O
T
ER
R A/
C O
PE
R
TU
R
A
- G
U
AR
D H
O U
SE
14024790
1:50 GRAPHIC SCALE (MILLIMETERS)
2500500 1500 50000
N TRUE
NORTH
KEY PLAN
B
IMPIANTO IDRO-SANITARIO PIANO
TERRA-GATE HOUSE
1 100 mm SANITARY. INVERT ELEVATION -1.07 M.
2 50 mm RPZ BACKFLOW PREVENTER VALVE 3 50 mm RPZ BACKFLOW PREVENTER VALVE 4 80 mm VTR 5 40 mm WATER METER
6 PROVIDE WATER HEATER STAND AND
DRAIN PAN. PIPE RELIEF VALVE AND
DRAIN PAN TO MOP SINK
1 : 50B3 PLUMBING GROUND LEVEL-GATE HOUSE
1 : 50B1 PLUMBING ROOF LEVEL-GATEHOUSE
C4
PP601 6
IMPIANTO IDRO-SANITARIO LIVELLO
COPERTURA- GATE HOUSE
1 SANITARIO DA 100 mm. I.E. -1.07 M.
2 MANDATA ACQUA FREDDA DI CONSUMO DA 50 mm
3 DISCONNETTORE RPZ DA 50 mm
4 VTR DA 80 mm
5 CONTATORE ACQUA DA 40 mm
6 PREVEDERE SUPPORTO SCALDA ACQUA E PIATTO
DI DRENAGGIO. COLLEGARE LA VALVOLA ED IL PIATTO
DI DRENAGGIO AL LAVASCOPE
ELEV. =
GROUND LEVEL FINISHED FLOOR
24.600
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A B C E F
D
SP
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
NOTES:
SHEET NOTES:
1. REFER TO DRAWING PP001 FOR GENERAL SHEET NOTES.
KEY NOTES: 00
NOTE:
NOTE DEL FOGLIO:
1. VEDERE IL DISEGNO PP001 PER LE NOTE
GENERALI DEL FOGLIO
NOTE DI RIFERIMENTO: 00
4750 New Broad Street Orlando, FL www.rlfae.com
1 : 100
R O
O F
PL
U
M
BI
N G
P
LA
N
SA
TC
O M
F
AC
IL
IT
Y
PP110A
CA
CRF CRF JEB
IM
PI
AN
TO
ID
R
O -S
AN
IT
AR
IO
C O
PE
R
TU
R
A
- S
AT
C
O M
F
AC
IL
IT
Y
14024789
N
TRUE
NORTH
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
KEY PLAN
A
1 : 100A2 ROOF PLUMBING PLAN-SATCOM FACILITY
1 80 mm VTR
2 (3) SOLAR PANELS MOUNTED TO ROOF.
3 SOLAR HOT WATER RETURN LOOP.
4 SOLAR HOT WATER SUPPLY LOOP.
1 VTR DA 80 mm
2 (3) PANNELLI SOLARI MONTATI IN COPERTURA
3 RITORNO ACQUA CALDA SOLARE
4 MANDATA ACQUA CALDA SOLARE
IMPIANTO IDRO-SANITARIO PIANTA
COPERTURA-SATCOM FACILITY
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
NOT TO SCALE
NOT TO SCALE NOT TO SCALE NOT TO SCALE
KEY NOTES:
FINISHED FLOOR.
KEY NOTES:
FLOOR STRAINER, FLUSH.
CAST IRON BODY, 180mm � STRAINER.
SUPPLEMENTARY STRAINER SCREWED
IN PLACE.
EXTENSION TO SEWER LINE
BRASS PLUG
CHROME PLATED BRONZE WALL PLATE
COMPATIBLE WITH TYPE FLOOR INSTALLED.
PROVIDE FLOOR PLATE TO BE
EXTENSION TO SOIL OR WASTE LINE
SOIL OR WASTE
A3 TYPICAL CARRIER DETAILS
C1 TYPICAL FLOOR DRAIN C3 TYPICAL CLEANOUT DETAIL C4 PLUMBING VENT THROUGH ROOF
KEY NOTES:
SLEEVE THROUGH ROOF
REFER TO SPECIFICATIONS FOR ROOF
TYPE AND FLASHING REQUIREMENTS.
VENT STACK LOCATIONS INDICATED ON PLANS
TURN LEAD DOWN INTO STACK
FLASHING AND COUNTERFLASHING
300mm MINIMUM STACK HEIGHT
TOILET SEAT
FINISHED WALL.
32mm WASTE & "P" TRAP
END OF O.D. TAIL PIECE
15mm SHUT OFF VALVE
FIXTURE HANGER.
SUPPORT ARM LOCKING DEVICE
FINISHED FLOOR.
WATER INLET 10mm O.D. COMPRESSION
BLOCK BASE PLATES (ANCHOR TO FLOOR).
FLUSH VALVE.
WASTE OR VENT.
EXTENDED FRONT FOR HANDICAPPED.
URINAL CARRIER.
WATER CLOSET CARRIER.
32mm WASTE AND "P" TRAP.
15mm HOT AND COLD WATER SUPPLIES WITH
NOZZLE
DRAIN
KEY NOTES:
WATER CLOSET, WALL HUNG, HANDICAPPED
URINAL, WALL HUNG
VITREOUS CHINA LAVATORY.
FAUCET - SEE SPECIFICATIONS
6mm VINYL PLASTISOL OR EQUAL.
WASTE AND P-TRAP SHALL BE INSULATED WITH
STOPS AND ESCUTCHEONS.
HANDICAPPED CLEARANCE LINE
CARRIER WITH CONCEALED ARMS.
BEARING PLATE
32mm W
203203
AGAINST FINISHED WALL
THAT LIP OF FRAME OVERLAPS AND BUTTS
MOUNTING FRAME MUST BE INSTALLED SO
WALL
CHILLER
32mm
MOUNTING
FRAME
C.O. TEE
FLOORWALLEXTERIOR
CONCRETE
450mm X 450mm X 200mm
DRAIN LINE TO "P" TRAP
HANDICAPPED COUNTER LAVATORYURINAL
OUTLET
WATER CLOSET
20mm
25mm
100mm WASTE
WALL HUNG LAVATORY
HI/LOW TYPE WATER COOLER
VENTILAZIONE ATTRAVERSO LA COPERTURAPARTICOLARI TIPICI TAPPI D'ISPEZIONEPILETTA A PAVIMENTO TIPICA
LINEA DI SCARICO A SIFONELINEA DI SCARICO A SIFONELINEA DI SCARICO A SIFONELINEA DI SCARICO A SIFONE
CALCESTRUZZO
CHE SIA COMPATIBILE CON IL TIPO DI PAVIMENTO
ESTENSIONE ALLA RETE DI SCARICO BIANCA O NERA.
PROVVEDERE PIASTRA A PAVIMENTO
PIASTRA A PARETE IN BRONZO CROMATO.
ESTENSIONE ALLA RETE DI FOGNATURA.
CALCESTRUZZO
INSTALLATO.
SCARICO BIANCO O NERO.
NOTE DI RIFERIMENTO:
TAPPO IN OTTONE.
ESTERNOESTERNO PARETEPARETE PAVIMENTOPAVIMENTO
REQUISITI DELLA COPERTURA E DELLA SCOSSALINA
SONO INDICATE SULLE PIANTE
ALTEZZA MINIMA CAMINO 300mm
NOTE DI RIFERIMENTO:
SCOSSALINA E CONTROSCOSSALINA
RIPIEGARE IN BASSO NEL CAMINO
MANICOTTO ATTRAVERSO LA COPERTURA
FARE RIFERIMENTO ALLE SPECIFICHE PER I
LE POSIZIONI DEI CAMINI DI VENTILAZIONE
LAVABO DA MOBILE PER DISABILIORINATOIO
USCITAUSCITA
SEDILE TAZZA
VASO A SEDERE
SCARICO DA 100mmSCARICO DA 100mm
SUPPORTO CON BRACCIA INCASSATE.
LINEA DI RISPETTO PER DISABILI.
FRONTALE ESTESO PER DISABILI.
DISPOSITIVO DI SUPPORTO E DI BLOCCAGGIO
SOSPENSIONE DELL'APPARECCHIO.
LAVABO SOSPESO A PARETE
22PIASTRA DI SUPPORTO.
FREDDA CON VALVOLE D'ARRESTO E BORCHIE.
ALIMENTAZIONI DA 15mm DI ACQUA CALDA E
SCARICO DA 32mm E SIFONE.
14 FLUSSOSTATO
SUPPORTO ORINATOIO.
SUPPORTO VASO IGIENICO.
SCARICO O VENTILAZIONE.
PIASTRE DELLA BASE DI BLOCCAGGIO (ANCORARE A PAVIMENTO).
BEVERINO ELETTRICO TIPO ALTO/BASSO
4 VALVOLA D'ARRESTO DA 15mm
SCARICO DA 32mm E SIFONE
PARETE FINITA.
NOTE DI RIFERIMENTO:
ENTRATA ACQUA DA 10mm A COMPRESSIONE
PAVIMENTO FINITO.
LAVABO IN VETROCHINA.
RUBINETTO-VEDI LE SPECIFICHE
ESTREMITA' DEL DIAMETRO ESTERNO DEL
32mm SCARICO
UGELLO
PEZZO DI CODA
SCARICO E SIFONE DEVONO ESSERE ISOLATI CON
ISOLAMENTO PLASTICO VINILICO DA 6mm O DA
UGUALE PRODOTTO
23 VASO IGIENICO, ANCORATO A PARETE, PER DISABILI.
24 ORINATOIO, ANCORATO A PARETE
NON IN SCALA
180 mm.
CORPO IN GHISA, FILTRO DA
FILTRO SUPPLEMENTARE AVVITATO
GRIGLIA DA PAVIMENTO, A FILO.
IN OPERA.
NOTE DI RIFERIMENTO:
PAVIMENTO FINITO.
NON IN SCALA
REFRIGERATORE
INTELAIATURA DI MONTAGGIO
MURO
L'INTELAIATURA DI MONTAGGIO
DOVRA' ESSERE INSTALLATA COSI
CHE IL FILO DEL TELAIO SUPERI E
SI ALLINEI ALLA FINITURA A PARETE
NON IN SCALA
PARTICOLARI TIPICI SUPPORTI
NON IN SCALA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP501
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024791
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
NOT TO SCALE NOT TO SCALE
NOT TO SCALE
KEY NOTES:
SUPPLY WATER PIPING.
STAINLESS STEEL CASING.
WATER HAMMER ARRESTER.
BELLOWS EXPANDED UNDER SHOCK
PDI (PLUMBING AND DRAINAGE INSTITUTE)
STAINLESS STEEL BELLOWS UNDER NORMAL
PRESSURE.
CONDITIONS.
125mm
TRAP
FINISHED FLOOR
0m m
SEALANT FUNNEL
M
IN
50mm, 80mm, 100mm
STAINLESS STEEL SEISMIC RESTRAINT
RELIEF DRAIN THROUGH WALL AND DOWN TO SPLASH BLOCK
STRAINER WITH CLEARANCE FOR SCREEN REMOVAL
BALL VALVE
THRUST BLOCK
DOMESTIC WATER SUPPLY
SUPPORT BRACKET FROM WALL OR FLOOR
DIELECTRIC UNION BETWEEN ABOVE-GROUND
NOTES:
RELIEF VALVE
SUPPLY TO DOMESTIC WATER SYSTEM
GATE VALVE
AND BELOW-GROUND PIPING
VENT
CHECK VALVE ASSEMBLY
TEST COCKS
NOTES:
MAINTAIN ACCESS RECCOMMENDED BY
MANUFACTURER.
DISCHARGE SIDE.
INCREASER.
FLEXIBLE CONNECTOR.
CHECK VALVE.
BALANCING VALVE.
BALL VALVE.
PROVIDE DISTANCE UPSTREAM & DOWNSTREAM
OF FLOW BALANCING VALVE AS RECOMMENDED
BY MANUFACTURER.
STRAINER.
HOT WATER RECIRCULATION PUMP.
DECREASER.
THERMOMETER.
PRESSURE GAUGE.
AIR GAP FITTING.
PIPE WASTE FULL SIZE TO HUB DRAIN.
20mm BALL VALVE WITH THREADED HOSE END, CHAIN AND CAP FOR STRAINER BLOW DOWN.
0m m A
FF
A1 BACKFLOW PREVENTER DETAIL A3 HOT WATER RECIRCULATION PUMP
C3 TYPICAL INDIRECT FLOOR DRAIN
C5 TYPICAL WATER HAMMER ARRESTOR
REDUCED-PRESSURE SYSTEM (65mm AND LARGER)
REDUCED-PRESSURE SYSTEM (50mm AND SMALLER)
POMPA DI RICIRCOLO ACQUA CALDAPARTICOLARE DISCONNETTORE IDRAULICO
SECONDO QUANTO RICHIESTO DAL COSTRUTTORE.
VALVOLA DI BILANCIAMENTO.
COSTRUTTORE.
LATO DI SCARICO.
COLLEGAMENTO FLESSIBILE.
VALVOLA A SFERA.
VALVOLA DI RITEGNO.
VALLE DELLA VALVOLA DI BILANCIAMENTO
PROVVEDERE LE DISTANZE A MONTE E A
MANTENERE L'ACCESSO INDICATO DAL
POMPA DI RICIRCOLO ACQUA CALDA.
RIDUZIONE.
FILTRO.
NOTE:
RACCORDO.
IMPIANTO RIDUTTORE DI PRESSIONE (65mm O PIU' GRANDE)
IMPIANTO RIDUTTORE DI PRESSIONE (50mm O PIU' PICCOLO)
NOTE:
VALVOLA A SARACINESCA
MANDATA ALL'IMPIANTO ACQUA DOMESTICA
VALVOLA DI SFIATO
GIUNTO DIELETTRICO TRA LE TUBAZIONI SOPRA
STAFFA DI SUPPORTO DAL MURO O PAVIMENTO
MANDATA ACQUA DOMESTICA
BLOCCO REGGISPINTA
VALVOLA A SFERA
FILTRO CON SPAZIO PER RIMOZIONE RETE
TUBAZIONE DI SFIATO ATTRAVERSO LA PARETE,
INCASTRO SISMICO IN ACCIAIO INOSSIDABILE
VENTILAZIONE
GRUPPO VALVOLA DI RITEGNO
RUBINETTI DI PROVA
TERRA E INTERRATE
SIFONE
SIGILLANTE
PAVIMENTO FINITO
IMBUTO
TIPICO SCARICO A PAVIMENTO INDIRETTO
TERMOMETRO.
MANOMETRO
NON IN SCALA
CONVOGLIATA AL PARASPRUZZI
MANICOTTO DISTANZIATORE
TUBO DI SCARICO DELLA STESSA MISURA DEL DRENAGGIO.
VALVOLA A SFERA DA 20 mm CON ESTREMITA'
FILETTATA PER MANICHETTA, CATENELLA E TAPPO
PER LO SCARICO DEL FILTRO.
TIPICO AMMORTIZZATORE DI COLPO D'ARIETE
SOFFIETTI IN ACCIAIO INOSSIDABILE IN
CONDIZIONI NORMALI.
NE DEL COLPO.
D'ARIETE SECONDO IL "PDI".
SOFFIETTI ESPANSI SOTTO LA PRESSIO
AMMORTIZZATORE IDRAULICO DI COLPO
TUBO DI MANDATA ACQUA.
NOTE DI RIFERIMENTO:
INVOLUCRO IN ACCIAIO INOSSIDABILE.
NON IN SCALA
NON IN SCALA
NON IN SCALA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP502
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024792
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
NOT TO SCALENOT TO SCALE
C5
MH5004
KEY NOTES:
BACKFLOW PREVENTER, TEE KEY AND BRASS FINISH.
FREEZELESS WALL HYDRANT WITH VACUUM BREAKER-
INSIDE FACE OF STRUCTURAL WALL.
20mm
C1 TYPICAL AIR CONTROL STATION DETAIL
C4 AIR COMPRESSOR PIPING DIAGRAM
A4 TYPICAL WALL HYDRANTA2 MOP BASIN DETAIL
5 7
KEY NOTES:
SUPPORT BRACKET.
VACUUM BREAKER.
BASIN.
FLOOR MOUNTED MOP
HOT AND COLD WATER
WRIST BLADE HANDLES.
SUPPLY PIPING.
80mm DRAIN CONNECTION.
DRAIN WITH STRAINER.
FINISHED WALL
PAIL HOOK.
0m m
4m m 230mm12 m m
0m m
M
IN
M
IN
HOLD TO MIN. DIMENSION FOR
INSTALLATION AND MAINTENANCE
SERVICE VALVE
SPLIT RING STAND-OFF
PIPE HANGERS MOUNTED
TO WALL (MAX.1050mm O.C.)
20mm X 300mm LONG
DIRT LEG WITH
DRAIN COCK
SAFETY PLUG
FILTER/DRYER
THREADED
NIPPLE (TYP.)
REGULATOR (206.8-689.5 kPA AT X) (413.7-1103.2 kPA AT X)
PRESSURE GAUGE
(0-1379 kPA)
20mm AIR TO
1.
M
ET
ER
S
A.
F.
F.
OUTLETS
20mm COMPRESSED AIR SUPPLY PIPING
KEY NOTES:
REFRIGERATED AIR DRYER
DUPLEX COMPRESSORS MOUNTED ON TANK.
MOTORS PRE-WIRED TO STARTER.
R
EF
ER
T
O
FRONT VIEW
FINISHED FLOOR
WALL FACE
VARIES
SIDE VIEW
AR
C
H
IT
EC
TU
R
AL
INTAKE AIR FILTER
PRESSURE RELIEF VALVE, SET 800 kPa
OIL FILTER
THICK CONCRETE HOUSEKEEPING PAD.
LIQUID DRAIN TRAP PRESSURE RELIEF.
PRESSURE GUAGE (0 - 1000kPa)
PRESSURE RELIEF VALVE, SET 800kPa. BY PASS
AUTOMATIC LIQUID DRAIN TRAP.
1067mm LENGTH X 1524 mm WIDE X 100mm THICK
SCHEMA TUBAZIONE ARIA COMPRESSA
COMPRESSORE D'ARIA DUPLICE MONTATO SUL SERBATOIO.
VALVOLA DI SOVRAPRESSIONE , TARATA A 800 kPa
MISURATORE DI PRESSIONE (0 - 1000kPa)
VALVOLA DI SOVRAPRESSIONE, TARATA A 800 kPa. BY PASS
DELLA VALVOLA DI SFIATO AL SIFONE DI DRENAGGIO DEL
SIFONE DI DRENAGGIO AUTOMATICO DEL LIQUIDO.
NOTE DI RIFERIMENTO:
FILTRO PRESA D'ARIA
MOTORI PRE-CABLATI FINO ALL'AVVIATORE.
ESSICCATORE D'ARIA REFRIGERATO
LIQUIDO.
FILTRO OLIO
MENSOLA DI SUPPORTO.
NOTE DI RIFERIMENTO:
ROMPIVUOTO.
SCARICO CON FILTRO
VOLANTINO AD ASTA
LAVASCOPE MONTATO
ACQUA CALDA E FREDDA
A PAVIMENTO.
GIREVOLE.
TUBI DI ALIMENTAZIONE
GANCIO DEL SECCHIO
PARETE FINITA -
ATTACCO SCARICO
DA 80 mm
PARTICOLARE LAVASCOPE
VISTA FRONTALE
PAVIMENTO FINITO
VARIABILE
VISTA LATERALE
NOTE DI RIFERIMENTO:
VISTA LATERALE
FACCIA INTERNA DELLA PARETE
FACCIA DEL MURO
PARTIC. TIPICO DI IDRANTE A PARETE
IDRANTE A PARETE ANTIGELO CON ROMPIVUOTO,
DISCONNETTORE, CHIAVE A "T" E FINITURA IN
OTTONE
PARTICOLARE TIPICO STAZIONE CONTROLLO ARIA
FILTRO ESSICCATORE
1.
M
ET
R I A
.F .F
MANOMETRO
REGOLATORE
VALVOLA DI SERVIZIO
NIPPLO FILETTATO (TIP.)
LASCIARE LA DIMENSIONE MINIMA
NECESSARIA PER INSTALLAZIONE
VALVOLA DI SCARICO
SCARICO LUNGO
CRAVATTA A DUE PEZZI
MONTATO A PARETE
20mm ARIA
ALLA PRESA
E MANUTENZIONE
SUPPORTO TUBAZ. TIPO A
(MAX.1050mm O.C.)
TRONCHETTO DI
20mm X 300mm CON
TUBAZIONE DI MANDATA ARIA COMPRESSA DA 20 mm
TAPPO DI SICUREZZA
FA
R
E R
IF
ER
IM
EN
TO
PEDANA DI SUPPORTO IN CLS.
1067mm LUN. X 1524 mm LARG. X 100mm ALT.
NON IN SCALA NON IN SCALA
NON IN SCALANON IN SCALA
AL
LA
A R
C H
IT
EC
TU
R
AL
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP503
CA
JEB CJF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024793
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
NOT TO SCALE
C2 PIPE SLEEVES THROUGH WALLS
A3 TYPICAL PIPE SLEEVE THROUGH FLOOR
A1 GUARDHOUSE WATER HEATER DETAIL
A4 WATER HEATER MOUNTED ABOVE MOP SINK
ET
T & P RELIEF VALVE. PIPE TO DRAIN PAN FULL SIZE.
ALUMINUM 600mm DIAMETER DRAIN PAIN.
25 mm DRAIN FITTING. ROUTE DRAIN TO MOP SINK.
VACUUM RELIEF VALVE
THERMAL EXPANSION TANK
TANK DRAIN VALVE
BALL VALVE
ELECTRIC WATER HEATER
FLOOR MOUNTED MOP SINK
NOTE: PROVIDE SEISMIC BRACING FOR WATER
HEATER AND FOR WATER HEATER STAND
MOP HANGER
SUPPORT BRACKET
FAUCET WITH PAILHOOK AND VACUUM BREAKER
WITH 457 mm HOSE AND HOLDER BRACKET
NOTE: COORDINATE MOUNTING HEIGHT WITH ALL
OTHER TRADES AND ENSURE IT IS KEPT HIGH AS
POSSIBLE, BUT MAINTAIN ROOM TO SERVICE THE
HEATER. COORDINATE STUD FRAMING AS
REQUIRED.
KEY NOTES:
KEY NOTES:
BACKUP MATERIAL
SEALANT, FIRE STOP MATERIAL
PIPE
25mm
PLACE.
SURFACES.
INSULATION.
STANDARD WEIGHT STEEL PIPE SLEEVE ANCHORED IN
BACK UP MATERIAL
STEEL PIPE SLEEVE OF SIZE TO PASS PIPE AND
TERMINATED SLEEVE FLUSH WITH FINISHED WALL
COAT EXTERIOR SURFACES WITH TAR COMPOUND.
SEAL OR CAULK SLEEVES THRU FIRE WALLS IN A SMOKE
TIGHT MANNER, WITH FIRE STOP MATERIAL.
PIPE INSULATION TO BE CENTERED IN SLEEVE. DO NOT
SUPPORT PIPE FROM SLEEVE.
SEAL SLEEVE WITH SEALANT
AND OF SIZE TO COMPLETELY COVER OPENING.
FINISHED ESCUTCHEON PLATE FLUSH AGAINST WALL,
CENTER PIPE IN SLEEVE
SHALL BE SEALED AIR TIGHT.
ALL INTERIOR AND EXTERIOR PENETRATIONS
KEY NOTES:
WATER HEATER STAND-12 GAUGE GALVANIZED
MOUNTED TO WALL AND SEISMICALLY BRACED
20 mm DOMESTIC COLD WATER SUPPLY
20 mm DOMESTIC HOT WATER SUPPLY
2m m
3/8" ALL THREAD ROD
SECURE TO STRUCTURE
KEY NOTES:
SEISMIC STRAPS
ANGLE BRACKET
SECURE TO STRUCTURE
DRAIN PAN
COVER EXPOSED EDGES
WITH INSULATION SIMILAR
TO HOT WATER PIPING
SYSTEM
RUN T&P DISCHARGE
LINE AND 1" DRAIN PAN
DRAIN LINE DOWN WALL,
SECURE PIPES TO WALL
METAL JACKET
PIPE WITHOUT INSULATION
PIPE WITH INSULATION
EXTERIOR WALL
INTERIOR WALL
FINISHED WALL
SEALING AND ANCHORING COLLAR.
NOTE DI RIFERIMENTO:
MATEIRALE AGGIUNTIVO
CAMICIA IN METALLO
TUBO CON ISOLAMENTO
TUBO SENZA ISOLAMENTO
TUBO
SIGILLANTE, MATERIALE RESISTENTE AL FUOCO
TUBO
MANICOTTO DI TUBO ATTRAVERSO
IL PAVIMENTO - TIPICO
PARETE ESTERNA
PARETE INTERNAPARETE INTERNA
COLLARE DI TENUTA E ANCORAGGIO.COLLARE DI TENUTA E ANCORAGGIO.
PARETE FINITAPARETE FINITA
NOTE DI RIFERIMENTO:
CATRAME.CATRAME.
ANCORATO IN OPERA.
MATERIALE DI RIEMPIMENTO.
DELLA PARETE FINITA.
MATERIALE RESISTENTE AL FUOCO.
ANCORATO IN OPERA.
MATERIALE RESISTENTE AL FUOCO.
DELLA PARETE FINITA.
MATERIALE DI RIEMPIMENTO.
MANICOTTO.MANICOTTO.
L'APERTURA.L'APERTURA.
FAR PASSARE IL TUBO E L'ISOLAMENTO.FAR PASSARE IL TUBO E L'ISOLAMENTO.
SIGILLARE IL MANICOTTO CON SIGILLANTE.
TERMINARE IL MANICOTTO A FILO DELLA SUPERFICIE
SIGILLARE O CIANFRINARE I MANICOTTI ATTRAVERSO
I MURI TAGLIAFUOCO CON SISTEMA ANTIFUMO CON
L'ISOLAMENTO DEL TUBO VA CENTRATO NELLA
TUBAZIONE. NON SUPPORTARE IL TUBO COL
BORCHIA RIFINITA INSTALLATA A FILO PARETE E DI
DIMENSIONI TALI DA COPRIRE COMPLETAMENTE
MANICOTTO IN TUBO D'ACCIAIO DIMENSIONATO PER
MANICOTTO PER TUBO IN ACCIAIO DI PESO STANDARD
RIVESTIRE LA SUPERFICIE ESTERNA CON COMPOSTO DI
TUBAZIONE. NON SUPPORTARE IL TUBO COL
L'ISOLAMENTO DEL TUBO VA CENTRATO NELLA
I MURI TAGLIAFUOCO CON SISTEMA ANTIFUMO CON
SIGILLARE O CIANFRINARE I MANICOTTI ATTRAVERSO
TERMINARE IL MANICOTTO A FILO DELLA SUPERFICIE
SIGILLARE IL MANICOTTO CON SIGILLANTE.
MANICOTTO IN TUBO D'ACCIAIO DIMENSIONATO PER
DIMENSIONI TALI DA COPRIRE COMPLETAMENTE
BORCHIA RIFINITA INSTALLATA A FILO PARETE E DI
RIVESTIRE LA SUPERFICIE ESTERNA CON COMPOSTO DI
MANICOTTO PER TUBO IN ACCIAIO DI PESO STANDARD3
CENTRARE IL TUBO NEL MANICOTTO.2 CENTRARE IL TUBO NEL MANICOTTO.
MANICOTTO DI TUBO ATTRAVERSO LE PARETI
TUTTE LE PENETRAZIONI INTERNE ED ESTERNE12
SARANNO FORTEMENTE ARIA SIGILLATA
NOTE DI RIFERIMENTO:
PARTICOLARI SCALDA
MANDATA ACQUA FREDDA DOMESTICA 20 mm
NOTA:PROVVEDERE CONTROVENTI ANTISISMICI
MANDATA ACQUA CALDA DOMESTICA 20mm
CONTENITORE SCALDA ACQUA ZINCATO 12 GAUGE
VALVOLA DI SICUREZZA. COLLEGARE ALLA COPPA DI SCARICO
GANCIO PORTA SCOPE
COPPA DI SCARICO IN ALLUMINIO 600mm
SCARICO 25mm. COLLEGARE LO SCARICO AL LAVASCOPE
VALVOLA DI SICUREZZA
VASO AD ESPANSIONE TERMICA
VALVOLA DI SCARICO SERBATOIO
VALVOLA A SFERA
SCALDA ACQUA ELETTRICO
LAVASCOPE MONTATO A PAVIMENTO
MONTATO A PARETE CON CONTROVENTI ANTISISMICI
PER LO SCALDA ACQUA E PER IL SUPPORTO DELLO
SCALDA ACQUA
ACQUA GUARDHOUSE
NON IN SCALA
NON IN SCALANON IN SCALA
MENSOLA
RUBINETTO CON GANCIO PER SECCHIO E ROMPIGETTO NON IN SCALA
CON MANICHETTA DA 457mm E MENSOLA DI SOSTEGNO
REGGETTE ANTISISMICHE
COPPA DI SCARICO
TUBI DI SCARICO T&P E TUBO DI
SCARICO CONDENSA DA 1"
LUNGO LA PARETE. FISSARE
I TUBI ALLA PARETE
NOTA: COORDINARE L'ALTEZZA DI MONTAGGIO
DELLO SCALDA ACQUA CON TUTTI GLI ALTRI
IMPIANTI E ASSICURARSI CHE SIA LA PIU' ALTA
POSSIBILE, MA PREVEDRE ADEGUATO SPAZIO DI
SERVIZIO. COORDINARE I FISSAGGI COME
RICHIESTO.
IL LAVASCOPE
SCALDA ACQUA MONTATO SOPRA
NOTE DI RIFERIMENTO:
MENSOLA FISSATA ALLA
STRUTTURA
TUTTE ASTE FILETTATE DA
3/8" FISSATE ALLA STRUTTURA
RIVESTIRE I BORDI ESPOSTI
CON ISOLANTE SIMILE A
QUELLO DELLE TUBAZIONI
ACQUA CALDA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP504
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024794
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
C4
PP507
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
C2 SEISMIC COUPLING DETAIL
B4 SEISMIC ANCHOR FOR COLD WATER SERVICE
A1 EMERGENCY FACE & EYE-WASH DETAIL
7 8
EYE/FACE WASH WITH CAPS.
FLOOR DRAIN.
STAY OPEN BALL VALVE WITH PUSH HANDLE.
ANCHOR TO WALL.
STAY OPEN BALL VALVE.
KEY NOTES:
TEMPERED WATER SUPPLY.
CW AND HW.
MIXING VALVE PROVIDED WITH EMERGENCY
SHOWER AND EYEWASH.
229mm
100mm
ALLOWABLE MOVEMENT
PIPE SLEEVE.
PROPER CONSTRUCTION INSPECTION, FROM A SEISMIC
STANDPOINT, REQUIRES THAT CONCRETE NOT INTERFERE
WITH THE ACTION OF THE FLEXIBLE COUPLING.
FLEXIBLE COUPLING.
EDGE OF CONCRETE FOOTER OR WALL
WATER STOP.
(OPTIONAL).
BITUMASTIC PACKING - MODULAR RUBBER SEAL
OKUM PACKING (OMIT IF RUBBER SEAL IS USED).
KEY NOTES:
PUSH
100mm
16mm DIAMETER
USED)
OAKUM PACKING (OMIT IF RUBBER SEAL IS
100mm
80mm
175mm
SEAL (OPTIONAL)
RUBBER GASKET
ALLOY BOLT (TYPICAL)
BITUMASTIC PACKING - MODULAR RUBBER
WATER STOP
FIXED RETAINER GLAND
FOLLOWER GLAND
6mm X 32mm IRON PIPE STRAP
6mm X 32mm PIPE CLAMP
FLANGE CONNECTION
EXTERIOR WALL
SLEEVE
KEY NOTES:
80mm 80mm
PARTICOLARE LAVA OCCHI/VISO DI EMERGENZA
ANCORAGGIO ANTISISMICO PER
E' USATA LA SIGILLATURA IN GOMMA)
GUARNIZIONE IN CANAPA (DA OMETTERE SE
ALIMENTAZIONE ACQUA FREDDA
GUARNIZIONE BITUMINOSA - SIGILLATURA
BULLONE IN LEGA (TIPICO)
GUARNIZIONE IN GOMMA
PREMISTOPPA SEGUENTE
PREMISTOPPA FISSO DI TENUTA
MANICOTTO
NOTE DI RIFERIMENTO:
PARETE ESTERNA
BARRIERA A TENUTA STAGNA
COLLEGAMENTO A FLANGIA
MORSETTO TUBO 6 mm x 32 mm
FASCETTA TUBO IN FERRO 6 mm x 32 mm
MODULARE IN GOMMA (OPZIONALE)
USATA SIGILLATURA IN GOMMA)
GUARNIZIONE IN CANAPA (OMETTERLA SE VIENE
GUARNIZIONE BITUMINOSA-SIGILLATURA IN GOMMA
MANICOTTO
MODULARE (OPZIONALE)
BARRIERA A TENUTA STAGNA
UNA CORRETTA ISPEZIONE DI COSTRUZIONE
DAL PUNTO DI VISTA ANTISISMICO, RICHIE-
DE CHE IL CEMENTO NON INTERFERISCA CON
L'AZIONE DELL'ACCOPPIAMENTO FLESSIBILE
GIUNZIONE FLESSIBILE
BORDO DELL'APPOGGIO IN CEMENTO O DELLA PARETE
MOVIMENTO CONSENTITO
NOTE DI RIFERIMENTO:
PARTICOLARE GIUNZIONE ANTISISMICA
SCARICO A PAVIMENTO
VALVOLA A SFERA CON
ANCORAGGIO A PARETE
VALVOLA A SFERA A
NOTE DI RIFERIMENTO:
MANDATA ACQUA MISCELATA
CW E HW.
PROVVEDERE MISCELATORE PER
DOCCIA DI EMERGENZA E LAVAOCCHI
COMANDO A SFERA
CHIUSURA MANUALE
LAVA OCCHI/VISO CON TAPP/
NON IN SCALA
NON IN SCALA
NON IN SCALA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP505
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024795
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
SEISMIC CONNECTIONS TO STRUCTURE
B
A
E
C
D
F
65x65x1.7
65x65x1.7
65x65x2.9
65x65x1.7
76x76x2.9
65x65x2.9
65x65x1.7
65x65x1.7
65x65x1.7
65x65x1.7
50x50x1.7
50x50x1.7
50x50x1.7
50x50x1.7
65x65x2.9
65x65x1.7
50x50x1.7
50x50x1.7
16.07
24.26
34.68
11.76
74.86
46.88
NOT TO SCALE
NOT TO SCALE
A1 SEISMIC PIPE BRACING
A3 SEISMIC CONNECTION TO STRUCTURE
REFER TO DETAIL A4/PP506 FOR CONNECTION TO STRUCTURE.
VERTICAL HANGERS ARE REQUIRED IN ADDITION TO THE HANGER ROD ONLY WHEN THE MAXIMUM LENGTH FOR RODS IS EXCEEDED.
1 MIN
2 MAX
38mm MAX
50mm MAX
(1)
(2)
(3)
(4)
(5)
APPLIES TO PIPE CONDUIT.
MAXIMUM LENGTH OF HANGER ROD WITHOUT VERTICAL HANGER SUPPORT.
PLACE STANDARD CUT WASHERS BETWEEN SHEET METAL ANGLES AND NUT.
BRACE ALL PIPING AS FOLLOWS:
BOLT WITH LOCK WASHER & NUT.
LARGER PIPES USE 100mm x 10mm STEEL PLATE.
TRANSVERSE ANGLE BRACE.
LONGITUDINAL ANGLE BRACE.
AT 12 METERS MAXIMUM.
C. BRACE ALL PIPES 65mm INSIDE DIAMETER & LARGER.
EXCEPTION: PIPING SUSPENDED BY INDIVIDUAL HANGERS
120mm USE 76mm x 6.4mm STEEL PLATE AND FOR PIPE HANGER ROD CLIP, FOR PIPE SIZES 60mm THROUGH
BRANCH LINES MAY NOT BE USED TO BRACE MAIN LINES.
METERS MAXIMUM AND LONGITUDINAL BRACING SHALL BE
FOR GAS PIPING TRANSVERSE BRACING SHALL BE AT 6
LONGITUDINAL BRACING SHALL BE AT 24 METERS MAXIMUM.
TRANSVERSE BRACING SHALL BE AT 12 METERS MAXIMUM.
WHERE THE HANGER IS ATTACHED, NEED NOT BE BRACED.
TOP OF THE PIPE TO THE BOTTOM OF THE SUPPORT
300mm OR LESS IN LENGTH, AS MEASURED FROM THE
D. WHERE PIPING IS LESS THAN 65mm AND MUST BE BRACED, BRACE PIPE AS REQUIRED FOR 65mm PIPE.
ROOMS THAT IS 32mm INSIDE DIAMETER & LARGER.
B. BRACE ALL PIPING LOCATED IN BOILER & MECHANICAL
A. GAS PIPING THAT IS 25mm INSIDE DIAMETER & LARGER.
VERTICAL HANGER.
6.4mm LARGER THAN THE OUTSIDE DIAMETER OF BOLT.
PIPE SLEEVE OVER BOLT THAT HAS AN INSIDE DIAMETER
HANGER ROD.
(6)
(7)
"L
(5) MAXIMUM
LENGTH FOR
150mm MAX
MIN.
ROD SIZE
mm�
TYPE TO
(1) CONNECTION
STRUCTUREmm�
BRACES
(4) LONGITUDINAL
(mm x mm x mm)
(2) MIN.
BOLT SIZE
(6)TRANSVERSE
BRACES
(3) VERTICAL
HANGERS
MAXIMUM
MASS PER
(4) PIPE SIZE
DIAMETER
mm� METER (kg/m) (mm x mm x mm)
NOTES:
(mm x mm x mm)
NOTES:
24 METERS OF PIPE/CONDUIT RUN.
RODS (mm)
EXCEPT AS NOTED OTHERWISE, PROVIDE TRANSVERSE BRACING AT EVERY 12 METERS AND LONGITUDINAL BRACING AT EVERY
G/2
25mm
TYPE F
32mm
G/2
TYPE A & B
GGG
TYPE C, D, & E
NOTES
STRUCTURAL
SUPPORTING
MEMBERS
ANGLE TO
L 90x65x10x80 LLH
L 130x80x10x80 LLH
2 - L 120x76x10x100 LLH
-2 - L 125x80x10x250 LLH
2 - L 150x90x10x100 LLH
2 - L 130x80x10x100 LLH
BOLT
(mm)
SIZE
EXPANSION
ANCHORS
15mm
16mm
2 - 15mm
(kg)
MAX. LOAD
CAPACITY
TYPE
A
C
B
2 - 15mm
4 - 15mm
2 - 20mm
D
E
F
NOTES:
A - F ARE SHOWN ON THIS DETAIL.
LLH = LONG LEG HORIZONTAL
"L" MAXIMUM LENGTH ALLOWED IS 1.8 METERS
(7
"G"
DIM.
(mm)
STRUCTURE
CONTROVENTATURA
PER IL COLLEGAMENTO ALLA STRUTTURA VEDERE IL PARTICOLARE A2/PP506.
LUNGHEZZA
PER LE BARRE
(5) MASSIMA
NOTE:
DIMENSIONE
DELLA BARRA
�mm
ALLA
STRUTTURA
ATTACCOLONGITUDINALE
(mm x mm x mm)
DIMENSIONE
DEL BULLONE
�mm
(1) TIPO DI(4) CONTROVENTATURA (2) MINIMA MINIMA
VERTICALI
PER METRO
(Kg/m)
MASSIMA DEL TUBO
NOTE:
(mm x mm x mm)
(3) SOSPENSIONI(4) DIAMETRO MASSA
TRASVERSALE
(mm x mm x mm)
CONTROVENTATURA
SI APPLICA AL CONDOTTO.
MASSIMA LUMGHEZZA DELLA BARRA.
LAMIERA E IL DADO.
SUPPORTO VERTICALI.
MASSIMA LUNGHEZZA DELLE BARRA DI SOSPENSIONE SENZA SOSPENSIONI DI
LE SOSPENSIONI VERTICALI SONO RICHIESTE IN AGGIUNTA ALLA BARRA DI SOSPENSIONE SOLO QUANDO VIENE SUPERATA LA
PIAZZARE UNA RONDELLA TAGLIATA STANDARD FRA GLI ANGOLARI IN
LA TABELLA RIPORTATA QUI SOTTO:
GRANDE.
INTERNO DI 25mm O SUPERIORE.
INTERNO DI 65mm O PIU' GRANDE.
2 ECCEZIONE: IL TUBO SOSPESO CON PROPRIE
DI CONTROVENTATURA.
(mm)
CONTROVENTARE LA LINEA PRINCIPALE.
CONTROVENTATURA TRASVERSALE AD ANGOLO.
24 METRI MASSIMO.
12 METRI MASSIMO.
10 mm.
DIAMETRO ESTERNO DEL BULLONE.
DIAMETRO INTERNO DI 6.4mm PIU' LARGO DEL
BARRA DI SOSPENSIONE.
SOSPENSIONE VERTICALE.
ABBIANO UN DIAMETRO INTERNO DI 32mm O PIU'
SALA CALDAIE E NELLA SALA MACCHINE E CHE
B. CONTROVENTARE TUTTI I TUBI UBICATI NELLA
A. LA TUBAZIONE DEL GAS CHE HA UN DIAMETRO
CONTROVENTARE TUTTE LE TUBAZIONI COME SEGUE:
C. CONTROVENTARE TUTTI I TUBI DI DIAMETRO
DOVE E' ATTACCATA LA SOSPENSIONE NON NECESSITA
DALLA SOMMITA' DEL TUBO AL FONDO DEL SUPPORTO
SOSPENSIONI LUNGHE 300mm O MENO, MISURATE
MANICOTTO SOPRA IL BULLONE CHE HA UN
PIU' GRANDI USARE PIASTRA DI ACCIAIO DA 100mm x PIASTRA IN ACCIAIO DA 76mm x 6.4mm E PER I TUBI
QUELLA LONGITUDINALE A 12 METRI AL MASSIMO.
TRASVERSALE DOVRA' ESSERE AL MASSIMO A 6 METRI E
PER LA TUBAZIONE DEL GAS LA CONTROVENTATURA
LA CONTROVENTATURA LONGITUDINALE DOVRA' ESSERE A
LA CONTROVENTATURA TRASVERSALE DOVRA' ESSERE A
TUBAZIONI DI DIAMETRO DA 60 A 120mm USARE
FERMO DELLA BARRA DI SOSPENSIONE DEL TUBO, PER
BULLONE CON RONDELLA DI FISSAGGIO E DADO.
CONTROVENTATURA LONGITUDINALE AD ANGOLO.
LE DIRAMAZIONI NON DEVONO ESSERE USATE PER
SALVO DIVERSA ANNOTAZIONE PROVVEDERE CONTROVENTATURA TRASVERSALE OGNI 12 METRI E LONGITUDINALE OGNI 24 METRI
DI LUNGHEZZA DEL CANALE. PROVVEDERE CONTROVENTATURA PER CANALI CIRCOLARI SECONDO
COLLEGAMENTI ANTISISMICI ALLA STRUTTURA
NOTE
STRUTTURALI
SUPPORTO DI
ELEMENTI
ANGOLARI A
ANCORAGGI AD
ESPANSIONEDI CARICO KgTIPO
CAPACITA' MAX.
NOTE: LLH = GAMBA LUNGA ORIZZONTALE
A - F SONO MOSTRATI IN QUESTO PARTICOLARE.
BULLONI
DIMENSIONE
LA MASSIMA LUNGHEZZA "L" AMMESSA E' DI 1.8m
"G"
DIM.
STRUTTURA
D. OVE VI SIANO TUBAZIONI INFERIORI A 65mm
CHE DEVONO ESSERE CONTROVENTATE, USARE LE
PRESCRIZIONI PER I TUBI DA 65mm.
ANTISISMICA PER TUBO
TIPO A & B TIPO C, D, & E TIPO F
COLLEGAMENTI ANTISISMICI ALLA STRUTTURA
NON IN SCALA
NON IN SCALA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP506
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024796
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
C1 4 PERSON WASH FOUNTAIN DETAIL
C4 THERMOSTATIC MIXING VALVE AT EW-1
A3 MIXING VALVE DETAILA1 GAS METER
DIRT LEG
KEY NOTES:
FINISHED GRADE
CONCRETE SUPPORT
REDUCER IF REQUIRED
60° FROM WATER HEATERS.
48°C HW SUPPLY.
MIXING VALVE BY-PASS.
CW SUPPLY.
KEY NOTES:
MIXING VALVE.
TEMPERATURE GAGE (TYPICAL).
UNION (TYPICAL).
BALL VALVE (TYPICAL).
HWR FROM RECIRCULATION.
PUMPS.
GATE VALVE (TYPICAL).
CHECK VALVE (TYPICAL).
BALANCING VALVE (TYPICAL).
TEMPERATURE AND PRESSURE
TEST PLUG (TYPICAL).
GAS LINE TO BUILDING.
UNION.
GAS PLUG COCK.
PRESSURE GAGE TAP.
REDUCING GAS REGULATOR.
GAS INLET LINE.
EARTHQUAKE VALVE (SEISMIC)
DIGITAL FLOWMETER WITH DDC OUTPUT
GAS METER.
REGULATED DOWN TO 13.8 kPa
CONNECT TO CW SUPPLYING
WATER HEATER.
15mm X 20mm
15mm15mm 20mm
20mm
20mm
40mm50mm
50mm
1 2
4 4
8 231
60 48
KEY NOTES:
SEMI-CIRCULAR WASH FOUNTAIN.
FRONT VIEW
TOP VIEW
SIDE VIEW
25mm CW/HW UP THROUGH FLOOR.
50mm DRAIN.
METERED ON/OFF VALVE FOR WATER SUPPLY.
FINISHED FLOOR.
KEY NOTES:
20 mm NPT. TEMPERED WATER OUTLET.
15 mm NPT. HOT WATER INLET.
15 mm NPT. COLD WATER INLET.
1. VALVE MUST MEET ANSI Z358.1 and ASSE 1071
GENERAL NOTES:
2. VALVE MUST BE ACCURATE TO WITHIN +/- (-16° C)
3. VALVE MUST HAVE INTEGRAL STRAINER CHECKSTOPS
ON INLETS.
4. VALVE MUST HAVE BUILT-IN COLD WATER BY-PASS,
ASSURING COLD FLOW.
DIAL THERMOMETER.
5. TEMPERATURE ADJUSTMENT WILL BE VANDAL RESISTANT.
TEMPERED WATER OUTLET SET POINT TO BE 30°C
PARTICOLARE VALVOLA MISCELATRICE
NOTE DI RIFERIMENTO:
1 60° DAGLI SCALDA ACQUA
ALIMENTAZIONE ACQUA CALDA A 43°C.
ESCLUSIONE VALVOLA MISCELATRICE .
ALIMENTAZIONE ACQUA FREDDA.
VALVOLA MISCELATRICE.
CALIBRO DI TEMPERATURA (TIPICO).
BOCCHETTONE (TIPICO).
VALVOLA A SFERA (TIPICO).
RITORNO DELL'ACQUA CALDA DALLE
POMPE DI RICIRCOLO.
10 VALVOLA A SARACINESCA (TIPICO).
11 VALVOLA DI RITENUTA (TIPICO).
12 VALVOLA DI EQUILIBRATURA (TIPICO).
13 SPINA DELLA PROVA DI PRESSIONE E
DI TEMPERATURA (TIPICO).
NOTE DI RIFERIMENTO:
LAVABO SEMICIRCOLARE
25mm CW/HW SALE ATTRAVERSO IL PAVIMENTO2
50mm SCARICO.3
VALVOLA DOSATRICE DI INTERCETTAZIONE EROGAZIONE ACQUA4
PAVIMENTO FINITO5
LAVABO SEMICIRCOLARE PER 4 PERSONE
VISTA LATERALE VISTA FRONTALE
VISTA DALL'ALTO
NOTE DI RIFERIMENTO:
20 mm NPT. USCITA ACQUA MISCELATA.1
15 mm NPT. INGRESSO ACQUA CALDA.2
15 mm NPT. INGRESSO ACQUA FREDDA.3
4 TERMOMETRO A QUADRANTE
USCITA ACQUA MISCELATA REGOLATA A 30° C.
1. LA VALVOLA DEVE ESSERE ANSI Z358.1 e ASSE 1071
NOTE GENERALI:
2. LA VALVOLA DEVE REGOLARE +/- (-16° C)
3. LA VALVOLA DEVE AVERE UN FILTRO ANTIRIFLUSSO
INCORPORATO SULL'INGRESSO
4. LA VALVOLA DEVE AVERE UN BY-PASS SULL'ACQUA FREDDA
PER ASSICURARE IL FLUSSO
5. IL CONTROLLO DELLA TEMPERATURA DEVE ESSERE ANTIVANDALO
MISCELATORE TERMOSTATICO EW-1
RIDUTTORE SE RICHIESTORIDUTTORE SE RICHIESTO
LINEA DI ARRIVO GAS.
FLUSSOMETRO DIGITALE CON USCITA DDC
VALVOLA ANTISISMICA
SUPPORTO IN CLSSUPPORTO IN CLS
INGRESSO GAS ALL'EDIFICIO.
RUBINETTO A MASCHIO PER GAS.
ATTACCO PER MANOMETRO.
NOTE DI RIFERIMENTO:
BOCCHETTONE.
ESTENSIONE
DI SPURGODI SPURGO
ESTENSIONE
TERRENO FINITOTERRENO FINITO
CONTATORE GAS
9 CONTATORE GAS
REGOLATORE RIDUTTORE GAS
REGOLATO A MENO DI 13.8 kPa
NON IN SCALA NON IN SCALA
NON IN SCALA
14 COLLEGHI AI RISCALDATORI DI ACQUA
DI FORNITURA DELLACCQUA FREDDA
NON IN SCALA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP507
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024797
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
REGULATOR VENT THRU ROOF WITH
RETURN BEND AND INSECT SCREEN.
TERMINATE A MINIMUM OF 10'-0" FROM
ALL SOURCES OF IGNITION AND 30'-0" FROM
ROOF
ALL AIR INTAKES . TYPICAL
20mm
20mm
50 mm 40 mm
20 mm 40 mm
25 mm
25 mm
50 mm
50 mm
25mm
25mm
25mm
25mm
NOT TO SCALEB3 SOLAR SCHEMATIC
610 mm MIN.
ROOF
SHWR
SH
W
SHWR
SHW
ET
TMV
RP
RP
RP
RP
SP
C5
MH5004
A4
PP509
A1
PP509
C3
PP508
0 bar
°C 80
0 120
°C40
3 6
0 bar
SOLAR SYSTEM STORAGE TANK WITH DOUBLE HEAT EXCHANGER
3 EA. FLAT PLATE SOLAR PANELS-SILE RT.
PRESSURE GAUGE
SOLAR CIRCUIT RETURN PIPE
SOLAR CIRCUIT SUPPLY PIPE
SOLAR CIRCUIT CIRCULATING PUMP
BALL-CHECK VALVE
MANUAL AIR VENT (TO BE USED AT FIRST FILLING OF INSTALLATION)
MEMBRANE TYPE EXPANSION TANK
FILLING GROUP
COLD WATER PIPE
SAFETY VALVE
DOMESTIC HOT WATER PIPE
FILLING PORT FOR ANTIFREEZE SOLUTION
KEY NOTES:
ELECTRONIC CONTROL PANEL FOR CIRCULATING PUMP
BALL VALVE
STORAGE TANK TEMPERATURE SENSOR
SOLAR PANELS TEMPERATURE SENSOR
HEATING HOT WATER SUPPLY PIPE
HEATING HOT WATER RETURN PIPE
STORAGE TANK DRAIN VALVE
TEMPERATURE SENSOR FOR HOT WATER BOILER
COMBINED TEMPERATURE/PRESSURE SAFETY VALVE
2438mm x 1372 mm x 100 mm HOUSEKEEPING PAD
ACCUMULATORE SOLARE CON DOPPIO
N°. 3 PANNELI SOLARI SILE RT
MANOMETRO
CIRCUITO DI RITORNO PANNELLI SOLARI
CIRCUITO DI M ANDATA PANNELLI SOLARI
CIRCOLATORE CIRCUITO PANNELLI SOLARI
VALVOLA A SFERA CON RITEGNO
ESPANSORE CHIUSO A MEMBRANA
GRUPPO DI RIEMPIMENTO
TUBAZIONE ACQUA FREDDA
VALVOLA DI SICUREZZA
TUBAZIONE ACQUA CALDA DOMESTICA
ATTACCO CARICAMENTO LIQUIDO ANTIGELO
NOTE DI RIFERIMENTO:
REG. ELETT. COMMANDO CIRCOLATORE
VALVOLA A SFERA
SONDA TEMPERATURA ACCUMULATORE SOLARE
SONDA TEMPERATURA PANNELLI SOLARI
TUBAZIONE MANDATA RISCALDAMENTO ACQUA CALDA
TUBAZIONE RITORNO RISCALDAMENTO ACQUA CALDA
SCARICO ACCUMULATORE SOLARE
SONDA TEMPERATURA BOLLITORE DI CALDAIA
VALVOLA MANUALE DI SFIATO ARIA (DA UTILIZZARSI
AL CARICO INIZIALE DELL'IMPIANTO)
VALVOLA DI SICUREZZA SENSIBILE A
TEMPERATURA E PRESSIONE
24 PEDANA DI SUPPORTO 2438mm x 1372 mm x 100 mm
REGOLATORE SFIATO ATTRAVERSO IL TETTO PIEGATO
E CON RETE ANTINSETTI. TERMINARE A 3.05m MINIMO DA FONTI DI FIAMMAE A 9.15m DA TUTTE LE PRESE
D'ARIA. TIPICO
COPERTURA
SCAMBIATORE DI CALORE
G
G
17 8
2 22
10 11
GAS SUPPLY
°C
48°C
TYP.
BY DIVISION 23
PANNELLI SOLARI
SCHEMA IMPIANTO
NON IN SCALA
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
L A
N T
C A
P
IT
A L
IM
P
R O
V E
M E
N T
S N
O R
F O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-11-D-1008 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
NTS
PL
U
M
BI
N G
D
ET
AI
LS
PP508
CA
CRF CRF JEB
PA
R
TI
C
O
LA
R I I
D R
IC
O
S
AN
IT
AR
IO
14024798
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
8 10
ELECTRICALLY BOND PIPE TO
PIPE INSUALTION
BUILDING STEEL STRUCTURE.
TRANSITION METAL TO PVC
PVC PIPE SLEEVE
SECURE WALL PARTITION
ACCOUSTICAL SEALANT-TYPICAL
METALLIC PIPE
SCHEDULE 80 PVC
METALLIC PIPE
ACCOUSTICAL SEALANT
KEY NOTES:
EYEWASH WITH CAPS.
FLOOR DRAIN.
STAY OPEN BALL VALVE WITH PUSH HANDLE.
ANCHOR TO WALL.
DRENCH SHOWER.
STAY OPEN BALL VALVE.
PULL HANDLE.
KEY NOTES:
TEMPERED WATER SUPPLY.
EMERGENCY ALARM SOUNDER.
EMERGENCY ALARM LIGHT.
EMERGENCY FLOW SWITCH.
CW AND HW.
MIXING VALVE PROVIDED WITH EMERGENCY
SHOWER AND EYEWASH.
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE NOT TO SCALE
A1 GAS/OIL FIRED WATER HEATER DETAIL
A4 SOLAR HOT WATER HEAT EXCHANGER TANK DETAIL
C1 PIPE PENETRATION THROUGH SECURE WALL
C4 EMERGENCY SHOWER AND EYE-WASH DETAIL
SOLAR HOT WATER TANK
990 mm
WITH DOUBLE HEAT EXCHANGER.
25mm DOMESTIC COLD WATER INLET
40mm MAGNESIUM ANODE
25mm WATER…
This is the start of the file's text. The full file is on GovTribe.