N62470-09-R9034_Part07-ST.pdf
PDF 8 MB Posted
- Solicitation number
- N33191-15-R-0802
About this file
Part 07 ST
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
G E
N E
R A
L N
O T
E S
SE001
CA
CMG FMN RDS
DESIGN DATA
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS:
A. ICC INTERNATIONAL BUILDING CODE, 2009 EDITION.
B. ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR BUILDINGS.
C. UFC 3-301-01 STRUCTURAL ENGINEERING WITH CHANGE 2.
D. ITALIAN D.M. 14 GENNAIO 2008 "NORME TECHNICHE PER LE COSTRUZION".
E. UFC 1-200-01 GENERAL BUILDING REQUIREMENTS
2. DESIGN LOADS ARE IN ACCORDANCE WITH UFC 1-200-01, UFC 3-301-01, IBC 2009,
AND ASCE 7-05, FOR AN OCCUPANCY CATEGORY IV BUILDING AND THE FOLLOWING:
A. GRAVITY LOADS:
ROOF (REDUCIBLE)
GROUND SNOW LOAD
FROST PENETRATION
IMPORTANCE FACTOR (SNOW)
FLOORS (UNLESS OTHERWISE NOTED - SEE SHEET SE100A)
B. LATERAL LOADS: WIND
BASIC WIND VELOCITY
BASIC WIND VELOCITY
WINDWARD PRESSURE COEFFICIENT
LEEWARD SUCTION COEFFICIENT
INTERNAL PRESSURE (INWARD AND OUTWARD)
EXPOSURE
IMPORTANCE FACTOR (WIND)
C. LATERAL LOADS: SEISMIC
BASIC SEISMIC FORCE RESISTING SYSTEM
SEISMIC (U.S. CRITERIA, IBC 2009)
SEISMIC BASE SHEAR (EQUIVA LENT LATERAL FORCE)
SITE CLASS
SPECTRAL RESPONSE ACCELERATIONS
SITE RESPONSE COEFFICENT
ADJUSTED SPECTRAL RESPONSE ACCELERATIONS
DESIGN SPECTRAL ACCELERATIONS
RESPONSE MODIFICATION FACTOR
SEISMIC RESPONSE COEFFICIENT
IMPORTANCE FACTOR (SEISMIC)
DESIGN CATEGORY
1.00 kPa (20 PSF)
1.00 kPa (20 PSF)
127MM (5 IN)
Is = 1.20
4.8 kPa (100 PSF)
145 KM/HR (90 MPH) FOR BUILDINGS
242 KM/HR (150 MPH) FOR RADOME
0.80 0.50
0.18 kPa (3.5 PSF) C Iw = 1.15
SPECIAL REINFORCED CONCRETE SHEAR
WALL
V = Cs*W D Ss = 1.20, S1= 0.31 Fa = 1.02, Fv = 1.78 Sms = 1.224, Sm1 = 0.552 Sds = 0.816, Sd1 = 0.368 R = 5 Cs = 0.245 Ie = 1.50 D
DATI DI PROGETTAZIONE
1. LA PROGETTAZIONE STRUTTURALE E’ IN CONFORMITA’ CON LE SEGUENTI SPECIFICHE:
A. ICC INTERNATIONAL BUILDING CODE, 2009 EDITION.
B. ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR BUILDINGS.
C. UFC 3-301-01 STRUCTURAL ENGINEERING WITH CHANGE 2.
D. D.M. ITALIANO. 14 GENNAIO 2008 "NORME TECNICHE PER LE COSTRUZIONI".
E. UFC 1-200-01 GENERAL BUILDING REQUIREMENTS
SEISMIC (ITALIAN CRITERIA D.M. 14 JAN. 2008)
REGION
NOMINAL LIFE
UTILIZATION COEFFICIENT
TOPOGRAPHIC CATEGORY
SOIL CATEGORY
HORIZONTAL ACCELERATION SLV
VERTICAL ACCELERATION SLV
HORIZONTAL STRUCTURAL COEFFICIENT FOR STEEL
VERTICAL STRUCTURAL COEFFICIENT FOR STEEL
SICILY
50 YEARS
T1 C Seh = 0.223g Sev = 0.145g q = 4 q = 1.50
GENERAL NOTES
1. THE GENERAL STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS AND
SPECIFICATIONS. SHOULD CONFLICTS EXIST BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND
THE GENERAL STRUCTURAL NOTES, THE STRICTEST PROVISION SHALL GOVERN.
NOTE GENERALI
LA NOTE GENERALI SONO DESTINATE AD AUMENTARE LE INFORMAZIONI INDICATE SUI DISEGNI E NELLE SPECIFICHE. ESISTESSERO CONFLITTI TRA I DISEGNI, LE SPECIFICHE E LE NOTE GENERALI STRUTTURALI, SARA’ APPLICATA LA CONDIZIONE PIU’ RIGOROSA.
LE STRUTTURE SONO PROGETTATE PER ESSERE AUTOPORTANTI E STABILI DOPO LA COMPLETA
COSTRUZIONE DELL’EDIFICIO. L’APPALTATORE E’ L’UNICO RESPONSABILE PER STABILIRE LA SEQUENZA E LE PROCEDURE DI COSTRUZIONE, PER ASSICURARE LA SICUREZZA DI TUTTI GLI ELEMENTI DELL’EDIFICIO DURANTE LA COSTRUZIONE E FORNIRA’ CONTROVENTI, TIRANTI E LEGATURE PROVVISORI NECESSARI PER IL COMPLETAMENTO DEI LAVORI. TALI MATERIALI RESTERANNO DI PROPRIETA’ DELL’APPALTATORE
DOPO IL COMPLETAMENTO DEI LAVORI.
SEGUIRE TUTTI I REGOLAMENTI E I CODICI DI SICUREZZA APPLICABILI DURANTE TUTTE LE FASI DI
COSTRUZIONE.
TUTTE LE CONDIZIONI E LE DIMENSIONI DELLE LINEE DI SERVIZIO ESISTENTI E LE COSTRUZIONI NEL SITO DOVRANNO ESSERE VERIFICATE DALL’APPALTATORE PRIMA DI PROCEDERE CON I LAVORI. QUESTI ACCERTAMENTI SARANNO EFFETTUATI CON SUFFICIENTE ANTICIPO PER OGNI FASE DI LAVORO ED ESTESI
AL MASSIMO POSSIBILE PER EVITARE RALLENTAMENTI NEI LAVORI.
I PARTICOLARI INTITOLATI O MARCATI COME “ TIPICO” SARANNO APPLICATI NON SOLTANTO DOVE SPECIFICATAMENTE INDICATO O RIFERITO, MA ANCHE IN TUTTI GLI ALTRI CASI DOVE LA NATURA DELLA COSTRUZIONE NE RICHIEDA L’UTILIZZO. L’APPLICAZIONE DEI PARTICOLARI TIPICI SARA’ DETERMINATA DA TITOLI O NOTE DESCRITTIVI INDICATI NEL PARTICOLARE, DA SPECIFICI RIMANDI AL PARTICOLARE, O DA CONDIZIONI DI COSTRUZIONE SIMILI AD ALTRE CONDIZIONI DOVE IL PARTICOLARE E’ STATO
SPECIFICATAMENTE INDICATO O RIFERITO.
COORDINARE LE POSIZIONI E LE DIMENSIONI DI TUTTE LE APERTURE IN TUTTI I MURI E SOLAI GETTATI IN OPERA, E LE POSIZIONI DEI COMPONENTI RICHIESTI DA ANNEGARE NEL CALCESTRUZZO, CON LE PRESCRIZIONI NEI DISEGNI ARCHITETTONICI ED IDRAULICI, MECCANICI ED ELETTRICI. L’APPALTATORE SARA’ RESPONSABILE DI INDIVIDUARE E COORDINARE LE DIMENSIONI RICHIESTE DI TUTTE LE APERTURE
E DEI COMPONENTI INCASSATI, PRIMA DI GETTARE IL CALCESTRUZZO.
I PESI DELLE APPARECCHIATURE E GLI ELEMENTI STRUTTURALI IN QUALUNQUE MODO RIFERITI AL SOSTEGNO DELLE APPARECCHIATURE O DELLE APERTURE SONO INDICATI SOLO A SCOPO INFORMATIVO.
VERIFICARE E COORDINARE DIMENSIONE, POSIZIONE E QUANTITA’ DELLE APERTURE ED I PESI DELLE
APPARECCHIATURE CON I FORNITORI ARCHITETTONICI, MECCANICI ED ELETTRICI. OTTENERE
L’APPROVAZIONE DEI FORNITORI INTERESSATI PRIMA DI PROCEDERE A TALI FASI DI LAVORO.
CAMBIAMENTI RICHIESTI PER ECCESSO DI PESO O DIFFERENZE GEOMETRICHE DELLE APPARECCHIATURE
SONO RESPONSABILITA’ DELL’APPALTATORE.
TUTTI I CARICHI E LE REAZIONI INDICATE NEI DISEGNI ED IN QUESTE NOTE GENERALI STRUTTURALI SONO CARICHI DI SERVIZIO NON FATTORIZZATI, SE NON DIVERSAMENTE INDICATO. CASI DI CARICO CHE INCLUDANO CARICHI COMBINATI SARANNO CALCOLATI IN CONFORMITA’ CON “INTERNATIONAL BUILDING
CODE”.
LA QUOTA 0.00 INDICATA SUI DISEGNI STRUTTURALI CORRISPONDE ALLA QUOTA PAVIMENTO FINITO QUALE PREDOMINANTE SUL PRIMO PIANO DI OGNI STRUTTURA DATA. VEDERE I DISEGNI CIVILI PER LE
QUOTE DI OGNI STRUTTURA.
5. DETAILS ENTITLED OR NOTED AS "TYPICAL" SHALL APPLY NOT ONLY WHERE
SPECIFICALLY INDICATED OR REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE
THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE. APPLICATION OF
TYPICAL DETAILS SHALL BE DETERMINED FROM DESCRIPTIVE TITLES OR NOTES
INDICATED ON THE DETAILS, FROM SPECIFIC CROSS-REFERENCES TO THE DETAILS,
OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER
CONDITION WHERE THE DETAIL IS SPECIFICALLY INDICATED OR REFERENCED.
6. COORDINATE THE LOCATIONS AND SIZES OF ALL OPENINGS IN CAST-IN-PLACE
WALLS AND FLOORS, AND LOCATIONS OF COMPONENTS REQUIRED TO BE
EMBEDDED IN THE CONCRETE, WITH THE ARCHITECTURAL DRAWINGS AND
PLUMBING, MECHANICAL AND ELECTRICAL REQUIREMENTS. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR PROPERLY LOCATING AND COORDINATING THE
REQUIRED SIZES OF ALL OPENINGS AND EMBEDDED COMPONENTS PRIOR TO
PLACING CONCRETE.
7. EQUIPMENT WEIGHTS AND STRUCTURAL ITEMS IN ANY WAY RELATED TO THE SUPPORT OF
EQUIPMENT OR OPENINGS ARE INDICATED FOR INFORMATIONAL PURPOSES ONLY. VERIFY AND
COORDINATE SIZE, LOCATION AND QUANTITY OF OPENINGS AND EQUIPMENT WEIGHTS
REQUIRED FOR ARCHITECTURAL, MECHANICAL AND ELECTRICAL TRADES. OBTAIN APPROVAL
OF AFFECTED TRADES BEFORE PROCEEDING WITH SUCH PORTION OF THE WORK. CHANGES
REQUIRED BY EQUIPMENT IN EXCESS OF THE WEIGHT OR GEOMETRIC ALLOWANCES ARE THE
CONTRACTOR'S RESPONSIBILITY.
2. THE STRUCTURES ARE DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING
IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURE AND SEQUENCE, TO INSURE THE SAFETY OF THE BUILDING AND ITS
COMPONENT PARTS DURING ERECTION, AND TO PROVIDE TEMPORARY BRACING, GUYS, OR
TIE-DOWNS AS NECESSARY FOR COMPLETION OF THE WORK. SUCH MATERIAL SHALL REMAIN
THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE WORK.
3. FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.
4. ALL CONDITIONS AND DIMENSIONS PERTAINING TO EXISTING UTILITIES AND CONSTRUCTION AT THE SITE SHALL BE VERIFIED BY THE CONTRACTOR BEFORE PROCEEDING WITH THE WORK. THIS
ASSESSMENT SHALL BE CONDUCTED SUFFICIENTLY IN ADVANCE OF ANY PHASE OF
CONSTRUCTION, TO THE MAXIMUM EXTENT POSSIBLE, TO AVOID DELAYS IN THE WORK.
8. ALL LOADS AND REACTIONS ON DRAWINGS AND IN THESE GENERAL STRUCTURAL NOTES ARE
UNFACTORED SERVICE LOADS UNLESS OTHERWISE NOTED. LOAD CASES WHICH INCLUDE
COMBINED LOADS SHALL BE CALCULATED IN ACCORDANCE WITH THE ICC INTERNATIONAL
BUILDING CODE.
9. ELEVATION 0.00 INDICATED ON THE STRUCTURAL DRAWINGS CORRESPONDS TO THE FINISHED
FLOOR ELEVATION WHICH PREDOMINATES ON THE FIRST FLOOR OF ANY GIVEN STRUCTURE.
SEE THE CIVIL DRAWINGS FOR THE ELEVATION DATUM OF EACH STRUCTURE.
ABBREVIATIONS /
3D
BOT
B.O. CONC
B.O. OPNG
CONC
CJ
CONT
CTJ
DIA (Ø)
FTG
L
LONG.
MAX
MIN
PLS
SIM
t
T & B
TYP
VERT
w/
THREE DIMENSIONAL
BOTTOM
BOTTOM OF CONCRETE
BOTTOM OF OPENING
CONCRETE
CONSTRUCTION JOINT
CONTINUOUS
CONTROL JOINT
DIAMETER
FOOTING
ANGLE
LONGITUDINAL
MAXIMUM
MINIMUM
PLACES
SIMILAR
WALL THICKNESS
TOP AND BOTTOM
TYPICAL
VERTICAL
WITH
TRIDIMENSIONALE
INFERIORE
INTRADOSSO DEL CALCESTRUZZO
INTRADOSSO DELL’APERTURA
CALCESTRUZZO
GIUNTO DI COSTRUZIONE
CONTINUO
GIUNTO DI CONTROLLO
DIAMETRO
FONDAZIONE
ANGOLO
LONGITUDINALE
MASSIMO
MINIMO
POSTI/POSIZIONI
SIMILE
SPESSORE MURO
SUPERIORE ED INFERIORE
TIPICO
VERTICALE
CON
ABBREVIAZIONI
2. I CARICHI DI PROGETTO SONO IN CONFORMITA’ CON UFC 1-200-01, UFC 3-301-01, IBC 2009, AND
ASCE 7-05, PER OCCUPANTI EDIFICIO CATEGORIA IV, E CON QUANTO SEGUE:
A. CARICHI ACCIDENTALI: GRAVITA’
CARICO ACCIDENTALE (RIDUCIBILE)
CARICO DELLA NEVE A TERRA
PENETRAZIONE DEL GELO
FATTORE DI IMPORTANZA (NEVE)
SOLAI (SE NON DIVERSAMENTE INDICATO)
B. CARICHI LATERALI: VENTO
VELOCITA’ DI BASE DEL VENTO
VELOCITA’ DI BASE DEL VENTO
COEFFICIENTE DI PRESSIONE SOPRAVENTO
COEFFICIENTE DI ASPIRAZIONE SOTTOVENTO
PRESSIONE INTERNA (IN ENTRATA E IN USCITA)
ESPOSIZIONE
FATTORE DI IMPORTANZA (VENTO)
C. CARICHI LATERALI: SISMICI
SISTEMA DI RESISTTENZA DELLA FORZA SISMICA ALLA BASE
SISMICI (U.S. CRITERIA, IBC 2009)
TAGLIO SISMICO ALLA BASE (FORZA LATERALE EQUIVALENTE)
CLASSE SITO
ACCELLERAZIONI DI RISPOSTA SPETTRALE
COEFFICIENTE DI RISPOSTA DEL SITO
ACCELLERAZIONI DI RISPOSTA SPETTRALE ADATTATE
ACCELLERAZIONI SPETTRALI DI PROGETTO
FATTORE DI RISPOSTA MODIFICATO
COEFFICIENTE DI RISPOSTA SISMICO
FATTORE DI IMPORTANZA (SISMICO)
CATEGORIA DI PROGETTO
1.00 kPa (20 PSF)
1.00 kPa (20 PSF)
127MM (5 IN)
Is = 1.20
4.8 kPa (100 PSF)
145 KM/HR (90 MPH) FOR BUILDINGS
242 KM/HR (150 MPH) FOR RADOME
0.80 0.50
0.18 kPa (3.5 PSF) C Iw = 1.15
PARETI SPECIALI A TAGLIO IN CALCESTRUZZO ARMATO
V = Cs*W D Ss = 1.20, S1= 0.31 Fa = 1.02, Fv = 1.78 Sms = 1.224, Sm1 = 0.552 Sds = 0.816, Sd1 = 0.368 R = 5 Cs = 0.245 Ie = 1.50 D
DATI DI PROGETTAZIONE
1.
2.
3.
4.
5.
6.
7.
8.
9.
N O T E G E N E R A
LI
SISMA (D.M. ITALIANO 14 JAN. 2008)
REGIONE
VITA NOMINALE
COEFFICIENTE DI UTILIZZAZIONE
CATEGORIA TOPOGRAFICA
CATEGORIA DEL TERRENO
ACCELLERAZIONE ORIZZONTALE SLV
ACCELLERAZIONE VERTICALE SLV
COEFFICIENTE STRUTTURALE ORIZZONTALE PER L’ACCIAIO
COEFFICIENTE STRUTTURALE VERTICALE PER L’ACCIAIO
SICILIA
50 ANNI
T1 C Seh = 0.223g Sev = 0.145g q = 4 q = 1.50
14024703
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
G E
N E
R A
L N
O T
E S
C
O N
T
IN
U E
D
SE002
CA
CMG FMN RDS
CONCRETE CONSTRUCTION NOTES
1. NO CONCRETE SHALL BE PLACED UNTIL ALL OPENINGS, EMBEDDED WORK, AND
EXCAVATIONS HAVE BEEN INSPECTED BY THE CONTRACTING OFFICER.
NOTE DI COSTRUZIONE DEL CALCESTRUZZO
IL CALCESTRUZZO NON SARA’ GETTATO PRIMA CHE TUTTE LE APERTURE, I COMPONENTI
INCASSATI E GLI SCAVI SIANO STATI ISPEZIONATI DALL’UFFICIALE CONTRAENTE.
L’ACCIAIO DI ARMATURA SARA’ IN BARRE AD ADERENZA MIGLIORATA SARANNO IN
CONFORMITA’ AL TIPO B450C AVENTE LE SEGUENTI CARATTERISTICHE MINIME:
CARICO DI ROTTURA - 540 MPa SNERVAMENTO - 450 MPa
ALLUNGAMENTO - 12%
IL COPRIFERRO MINIMO PER LE ARMATURE SARA’ COME INDICATO SUI DISEGNI .DOVE IL
COPRIFERRO NON E’ DIMENSIONATO USARE LO STESSO PER ELEMENTI SIMILI. DOVE NON VI
SIANO ELEMENTI SIMILI CHE INDICHINO IL COPRIFERRO, USARE QUANTO SEGUE:
A. CALCESTRUZZO GETTATO CONTRO TERRA - 75mm
B. CALCESTRUZZO GETTATO CONTRO CASSEFORME
ED ESPOSTO A TERRA O INTEMPERIE - 50mm
C. CALCESTRUZZO GETTATO CONTRO CASSEFORME
E NON ESPOSTO A TERRA O INTEMPERIE – SOLETTA DA 150mm – 50mm SOLETTA DA 200mm – 60mm MURI – 20mm TRAVI E PILASTRI – 40mm
TUTTI I BORDI DEL CALCESTRUZZO A FACCIA VISTA SARANNO SMUSSATI DI 15 MILLIMETRI
O COME INDICATO.
LE ARMATURE INDICATE CONTINUE (CONT.) SARANNO SOVRAPPOSTE PER 64 DIAMETRI
DELLA BARRA, SE NON DIVERSAMENTE INDICATO.
LE ARMATURE INDICATE ”GANCIO STANDARD” SARANNO COME DA PARTICOLARE SU QUESTA
TAVOLA, SE NON DIVERSAMENTE INDICATO.
TUTTE LE ARMATURE SARANNO TENUTE SALDAMENTE IN POSIZIONE PER EVITARE
SPOSTAMENTI DURANTE LE OPERAZIONI DI GETTO.
PROVVEDERE MATERIALE PER GIUNTO DI ESPANSIONE PREFORMATO SPESSO 15mm DOVE LE
SOLETTE A TERRA SI ATTESTANO CONTRO MURI, TRAVI A TERRA E PILASTRI.
TUTTI I GIUNTI CON SEGATRICE NEI SOLAI IN CALCESTRUZZO GETTATO IN OPERA SARANNO
REALIZZATI ENTRO 12 ORE DOPO IL GETTO DEL CALCESTRUZZO.
TUTTE LE ARMATURE SALDATE SARANNO IN CONFORMITA’ AL D.M. 14/01/2008 CLASSE
B450C.
LE “STAFFE CHIUSE” PER ARMATURE SARANNO COME DA PARTICOLARE SU QUESTA TAVOLA,
SE NON DIVERSAMENTE INDICATO.
LE “STAFFE APERTE” PER ARMATURE SARANNO COME DA PARTICOLARE SU QUESTA TAVOLA,
SE NON DIVERSAMENTE INDICATO.
2. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO TYPE B450C
HAVING THE FOLLOWING MINIMUM CHARACTERISTICS:
ULTIMATE TENSILE STRENGTH - 540 MPa YIELD POINT - 450 MPa
ELONGATION - 12%
3. MINIMUM CONCRETE COVER FOR THE REINFORCEMENT SHALL BE AS DETAILED ON
THE DRAWINGS. WHERE THE COVER IS NOT DIMENSIIONED, USE THE SAME FOR
SIMILAR ITEMS. WHERE NO SIMILAR ITEMS INDICATE THE AMOUNT OF COVER, USE
FOLLOWING:
A. CONCRETE DEPOSITED AGAINST THE EARTH - 75mm
B. CONCRETE DEPOSITED AGAINST FORMS AND
EXPOSED TO EARTH OR WEATHER - 50mm
C. CONCRETE DEPOSITED AGAINST FORMS
NOT EXPOSED TO WEATHER OR EARTH: 150mm SLAB - 50mm 200mm SLAB - 60mm WALLS - 20mm BEAMS AND COLUMNS - 40mm
4. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 15 MILLIMETERS OR AS
SHOWN.
5. REINFORCING STEEL MARKED `CONTINUOUS' (CONT.) SHALL BE LAPPED 64 BAR
DIAMETERS, UNLESS OTHERWISE NOTED.
6. REINFORCING STEEL MARKED `STANDARD HOOK' SHALL BE AS DETAILED ON THIS
SHEET, UNLESS OTHERWISE NOTED.
7. ALL REINFORCING STEEL SHALL BE HELD SECURELY IN PLACE TO PREVENT
DISLOCATIONS DURING THE POURING OPERATION.
8. PROVIDE 15 MILLIMETERS THICK PREMOLDED EXPANSION JOINT (PEJ) MATERIAL
WHERE SLABS-ON-GRADE ABUT WALLS, GRADE BEAMS AND COLUMNS.
9. ALL SAW CUT JOINTS IN CAST-IN-PLACE CONCRETE FLOORS SHALL BE PREFORMED
WITHIN 12 HOURS AFTER PLACEMENT OF THE FLOOR SLAB CONCRETE.
10. ALL REINFORCEMENT THAT IS WELDED SHALL CONFORM TO D.M. 14/01/2008 GRADE B450C.
11. `CLOSED TIES' FOR REINFORCING SHALL BE AS DETAILED ON THIS SHEET,
UNLESS OTHERWISE NOTED.
12. `CROSSTIES' FOR REINFORCING SHALL BE AS DETAILED ON THIS SHEET,
UNLESS OTHERWISE NOTED.
STEEL CONSTRUCTION NOTES
1. ROLLED STEEL SHAPES, BARS AND PLATES SHALL CONFORM TO TYPE S355 (Fe 510)
HAVING THE FOLLOWING MINIMUM CHARACTERISTICS:
NOTE DI COSTRUZIONE DELL’ACCIAIO
ELEMENTI IN ACCIAIO LAMINATO, BARRE E PIASTRE SARANNO IN CONFORMITA’AL TIPO S355
(Fe510) AVENTE LE SEGUENTI CARATTERISTICHE MINIME:
CARICO DI ROTTURA – 500 MPa SNERVAMENTO – 350 MPa
ALLUNGAMENTO – 20%
I BULLONI SARANNO IN ACCIAIO AD ALTA RESISTENZA IN CONFORMITA’ AD UNI EN ISO 898-1 CLASSE 10.9. I COLLEGAMENTI MOSTRATI SUI DISEGNI DI CONTRATTO FANNO SUPPORRE CHE LA
PORZIONE FILETTATA DEL BULLONE.
I DADI PER I BULLONI AD ALTA RESISTENZA SARANNO ESAGONALI PESANTI IN CONFORMITA’
AD UNI EN 14399 E UNI EN 20898-2, TIPO ESAGONALE PESANTE, CLASSE 10.
LE RONDELLE PER I BULLONI AD ALTA RESISTENZA SARANNO IN CONFORMITA’ AD UNI EN 10083-2
E UNI 14399-5.
GLI ELETTRODI PER SALDATURA METALLICA AD ARCOSARANNO CONFORMI ALLE PRESCRIZIONI
DI UNI 5132. IL METALLO PER SALDATURA AVRA’ UN CARICO DI ROTTURA MINIMO
UGUALE E NON MINORE DI 480 MPa.
LA SALDATURA SARA’ ESEGUITA IN FABBRICA NEL MAGGIOR NUMERO DI CASI POSSIBILI.
IN OGNI CASO LA SALDATURA SUL POSTO SARA’ PERMESSA PER QUALSIASI SALDATURA
INDICATA SU QUESTI DISEGNI DOVE SIA NECESSARIO FACILITARNE IL MONTAGGIO.
2. BOLTS SHALL BE HIGH STRENGTH STEEL FASTENERS CONFORMING TO
UNI EN ISO 898-1 CLASS 10.9. CONNECTIONS SHOWN ON CONTRACT DRAWINGS
ASSUME THAT THREADED PORTIONS OF THE BOLTS ARE NOT IN THE SHEAR PLANE.
3. NUTS FOR HIGH STRENGTH BOLTS SHALL BE HEAVY HEX CONFORMING TO UNI EN 14399, AND
UNI EN 20898-2, HEAVY HEX STYLE, CLASS 10.
5. ELECTRODES FOR MANUAL SHIELDED METAL-ARC WELDING SHALL CONFORM TO
THE REQUIREMENTS OF UNI 5132. THE WELDED METAL SHALL PROVIDE A MINIMUM
TENSILE STRENGTH EQUAL TO NOT LESS THAN 480 MPa.
6. WELDING SHALL BE PERFORMED IN THE FABRICATION SHOP TO THE GREATEST
EXTENT POSSIBLE. HOWEVER, FIELD WELDING SHALL BE PERMITTED FOR ANY
WELDS SHOWN ON THESE DRAWINGS WHERE IT IS NECESSARY TO FACILITATE
ERECTION.
STANDARD HOOKS
GANCI STANDARD
90° db
D
12db
-OR-
-O-
4d b
D db
180° db D
12db
CLOSED TIES
STAFFE CHIUSE
D
CROSSTIES
STAFFE APERTE
5°
6d b
6db
D90°
ULTIMATE YIELD STRENGTH - 500 MPa YIELD POINT - 350 MPa
ELONGATION - 20%
4. WASHERS FOR HIGH STRENGTH BOLTS SHALL BE CONFORMING TO UNI EN 10083-2 AND UNI
14399-5.
DATUM FOR ELEVATIONS GIVEN THIS PROJECT ARE FINISHED GROUND FLOOR ELEVATIONS:
A. SATCOM FACILITY 24.875m = 0.00 B. GUARDHOUSE 24.60m = 0.00
C. RADOME SLABS VARIES, SEE CIVIL DRAWINGS = 0.00
DATUM NOTES
NOTE SUI DATI
I DATI PER LE QUOTE IN QUESTO PROGETTO SONO RIFERITI ALLA QUOTA DEL PIANO TERRA FINITO:
A. SATCOM FACILITY 24.875m= 0.00 B. GUARDHOUSE 24.60m = 0.00
C. SOLETTE RADOME VARIE, VEDERE DISEGNI CIVILI = 0.00
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
1.
2.
3.
4.
5.
6.
N O T E G E N E R A
LI
S E G U
IT
O
14024704
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
2 1
2 2
5 5
1.0m
1.0m 1.0m
1.0m
1.0m
1.0m
2.2m
2.2m
2.2m
2.2m
2.2m
2.2m2.2m
2.2m
NOTES:
ZONE
TRIBUTARY AREA
COMPONENTS AND CLADDING WIND PRESSURES, UNFACTORED (kPa)
POSITIVE PRESSURES ACT INWARD, TOWARD THE WIND SURFACE.1.
≤ 1.0 SM
+0.61 -0.97
+0.61 -1.68
+0.61 -2.50
+1.06 -1.15
+1.06 -1.42
2.0 SM
+0.56 -0.95
+0.56 -2.33
+1.01 -1.10
+1.01 -1.32
5.0 SM
+0.50 -0.91
+0.50 -1.37
+0.50 -2.11
+0.94 -1.04
+0.94 -1.20
+0.48 -0.88
+0.48 -1.24
+0.48 -1.95
+0.90 -1.00
+0.90 -1.10
+0.56 -1.55
≥ 9.0 SM
PRESSURES GIVEN ARE UNFACTORED AND INCLUDE NO GRAVITY
LOADS.
2.
LINEAR INTERPOLATION IS PERMITTED FOR INTERMEDIATE
TRIBUTARY AREAS.
3.
DIAGRAMMI ELEMENTI E RIVESTIMENTI PER LA
PRESSIONE DEL VENTO
AREA DI IMMISSIONE
ZONA
PRESSIONE POSITIVAAD AZIONE INTERNA, VERSO LA SUPERFICIE DEL
VENTO.
1.
NOTE:
I DATI DI PRESSIONE SONO NON FATTORIZZATI ED INCLUDONO
CARICHI NON A GRAVITA'.
2.
L'INTERPOLAZIONE LINEARE E' PERMESSA PER AREE DI IMMISSIONE
INTERMEDIE.
3.
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
1 : 1
C O
M P
O N
E N
T S
A N
D C
LA
D
D
IN
G W
IN
D
P R
E S
S U
R E
S D
IA
G
R A
M S
SE003
CA
CMG FMN RDS
GATEHOUSE - SOUTHEAST VIEW
SATCOM FACILITY - SOUTHEAST VIEW
SATCOM FACILITY – VISTA SUD-EST
GATEHOUSE - VISTA SUD-EST
NO SCALE
D
IA
G R A M M I E L E M E N T I E
R
IV
E S T
IM
E N T I P E R L A P R E S S
IO
N E D E L V E N T O
14024705
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
50 CLEAR
300 , TYP
250 CONCRETE WALL
MURO IN CALCESTRUZZO
1-Ø10 (MIDDLE OF
SLAB) AT RE-ENTRANT
CORNER, EACH SIDE
(AL CENTRO SOLETTA)
ALLO SPIGOLO
RIENTRANTE, SU ENTRAMBI
I LATI
RE-ENTRANT
CORNER
SPIGOLO RIENTRANTE
Ø10/300 MIDDLE
OF SLAB
AL CENTRO SOLETTA
CONCRETE SLAB
SOLETTA IN CALCESTRUZZO
TIPICO
ROUPH OPENING
APERTURA GREZZA
1-Ø10 (MIDDLE OF SLAB)
(AL CENTRO SOLETTA)
NETTO
50 CLEAR
300 , TYP
200 CONCRETE WALL
MURO IN CALCESTRUZZO
1-Ø10 (MIDDLE OF
SLAB) AT RE-ENTRANT
CORNER, EACH SIDE
RE-ENTRANT
CORNER
Ø10/300 MIDDLE
OF SLAB
CONCRETE SLAB
SOLETTA IN CALCESTRUZZO
TIPICO
ROUPH OPENING
1-Ø10 (MIDDLE OF SLAB)
PREFORMED JOINT FILLER
RIEMPITIVO GIUNTO A ESPASIONE
CONSTRUCTION JOINT
GIUNTO DI COSTRUZIONE
(AL CENTRO SOLETTA)
ALLO SPIGOLO
RIENTRANTE, SU ENTRAMBI
I LATI
SPIGOLO RIENTRANTE
APERTURA GREZZA
(AL CENTRO SOLETTA)
NETTO
AL CENTRO SOLETTA
FLOOR PENETRATION
ATTRAVERSAMENTO A
PAVIMENTO
2-Ø10x1000
MIDDLE OF SLAB, TYP
AL CENTRO SOLETTA, TYP
033000.B01
SEE PLAN FOR
THICKNESS AND
ELEVATION
VEDERE PIANTA PER
SPESSORE E QUOTA
032001.W01
SEE PLAN FOR SLAB ON
GRADE REINFORCING
VEDERE PIANTA PER
ARMATURA SOLETTA A TERRA
033000.V02 033000.C02
150 THICK POROUS
FILL MATERIAL
MATERIALE POROSO DI
RIEMPIMENTO SPESSORE 150
COMPACTED SELECT
FILL MATERIAL
MATERIALE SELEZIONATO DI
RIEMPIMENTO COMPATTATO
C
L E
A R
S
L A
B C
L E
A R
S
L A
B
N E T T O S O
LE
T T A D A
N E T T O S O
LE
T T A D A
033000.B01
SEE PLAN FOR
THICKNESS AND
ELEVATION
VEDERE PIANTA PER
SPESSORE E QUOTA
032001.W01
SEE PLAN FOR SLAB ON
GRADE REINFORCING
VEDERE PIANTA PER
ARMATURA SOLETTA A TERRA
N E T T O S O
LE
T T A D A
N E T T O S O
LE
T T A D A
033000.V02 033000.C02
150 THICK POROUS
FILL MATERIAL
MATERIALE POROSO DI
RIEMPIMENTO SPESSORE 150
COMPACTED SELECT
FILL MATERIAL
MATERIALE SELEZIONATO DI
RIEMPIMENTO COMPATTATO
PREVIOUS POUR NEW POUR
NUOVO GETTOGETTO PRECEDENTE
15 MIN 600 LAP
SOVRAPPOSIZIONE
M
A X
M A X
MIN
SIGILLANTE
SEALANT
E Q
U A
L
U G U A
LE
C
L E
A R
S
L A
B C
L E
A R
S
L A
B
INTERRUPT 50% OF
REINFORCEMENT AT
CONSTRUCTION JOINT (CJ)
INTERROMPERE IL 50% DELLE
ARMATURE AL GIUNTO DI
COSTRUZIONE
033000.B01
SEE PLAN FOR
THICKNESS AND
ELEVATION
VEDERE PIANTA PER
SPESSORE E QUOTA
032001.W01
SEE PLAN FOR SLAB ON
GRADE REINFORCING
VEDERE PIANTA PER
ARMATURA SOLETTA A TERRA
033000.V02 033000.C02
150 THICK POROUS
FILL MATERIAL
MATERIALE POROSO DI
RIEMPIMENTO SPESSORE 150
COMPACTED SELECT
FILL MATERIAL
MATERIALE SELEZIONATO DI
RIEMPIMENTO COMPATTATO
t /
4 SIGILLANTE
SEALANT
6 MIN
MIN
INTERRUPT 50% REINFORCEMENT
AT CONTROL JOINTS (CTJ)
INTERROMPERE IL 50% DELLE
ARMATURE AL GIUNTO DI CONTROLLO
C
L E
A R
S
L A
B C
L E
A R
S
L A
B
GIUNTO TAGLIATO
CON SEGATRICE
SAW CUT JOINT
N E T T O S O
LE
T T A D A
N E T T O S O
LE
T T A D A
033000.B01
SEE PLAN FOR
THICKNESS AND
ELEVATION
VEDERE PIANTA PER
SPESSORE E QUOTA
032001.W01
SEE PLAN FOR SLAB ON
GRADE REINFORCING
VEDERE PIANTA PER
ARMATURA SOLETTA A TERRA
N E T T O
033000.V02 033000.C02
150 THICK POROUS
FILL MATERIAL
MATERIALE POROSO DI
RIEMPIMENTO SPESSORE 150
COMPACTED SELECT
FILL MATERIAL
MATERIALE SELEZIONATO DI
RIEMPIMENTO COMPATTATO
NEW POUR PREVIOUS POUR
E Q
U A
L
U G U A
LE
C
L E
A R
NUOVO GETTO GETTO PRECEDENTE
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
As indicated
T Y
P
IC
A L
S
LA
B D
E T
A
IL
S
SE004
CA
CMG FMN RDS
MATERIAL NOTES / NOTE DEI MATERIALI
NOTES:
SHEET NOTES:
NOTE:
NOTE DEL FOGLIO:
1. SEE SHEET SE002 FOR CONCRETE CONSTRUCTION NOTES.1. VEDERE FOGLIO SE002 PER NOTE DI COSTRUZIONE DEL CALCESTRUZZO.
TYPICAL DETAIL SHOWING ADDED SLAB REINFORCING
AT INTERIOR DOOR OPENINGS
NO SCALE / NON IN SCALA
PARTICOLARE TIPICO MOSTRANTE L’ARMATURA ADDIZIONALE
NELLA SOLETTA ALLE APERTURE DELLE PORTE INTERNE
TYPICAL DETAIL SHOWING ADDED SLAB
REINFORCING AT EXTERIOR DOOR OPENINGS
NO SCALE / NON IN SCALA
PARTICOLARE TIPICO MOSTRANTE L’ARMATURA ADDIZIONALE
NELLA SOLETTA ALLE APERTURE
TYPICAL DETAIL SHOWING ADDED SLAB
REINFORCING AT FLOOR PENETRATIONS
NO SCALE / NON IN SCALA
PARTICOLARE TIPICO MOSTRANTE L’ARMATURA
ADDIZIONALE NELLA SOLETTA AGLI
ATTRAVERSAMENTI A PAVIMENTO
TYPICAL SLAB DETAIL
NO SCALE / NON IN SCALA
PARTICOLARE TIPICO SOLETTA
SLAB CONSTRUCTION JOINT (CJ) DETAIL
NO SCALE / NON IN SCALA
PARTICOLARE GIUNTO DI COSTRUZIONE
NELLA SOLETTA
SLAB CONTROL JOINT (CTJ) DETAIL
NO SCALE / NON IN SCALA
PARTICOLARE GIUNTO DI CONTROLLO NELLA
SOLETTA
032001.W01 033000.B01 033000.C02 033000.V02
REINFORCING STEEL
CONCRETE SLAB
CONCRETE MUD SLAB
VAPOR RETARDER
/ ACCIAIO DI ARMATURA
/ SOLETTA IN CALCESTRUZZO
/ PLATEA IN CLS
/ RITARDANTE DI VAPORE
CONSTRUCTION JOINT (CJ) AT DEPRESSED SLAB
NO SCALE / NON IN SCALA
GIUNTO DI COSTRUZIONE NELLA SOLETTA
RIBASSATA
P A R T
IC
O
LA
R E T
IP
IC
O S O
LE
T T A
14024706
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
MASSIMO MASSIMO
VEDERE
PIANTA
SHEET NOTES:
KEY NOTES:
MATERIAL NOTES
M
A X
IM
U
M t/3
8 8
8 88 t t
X t t
X t tt t t
1000 LAP
t
SPEZZONI DALLA FONDAZIONE
PROSPETTO
SEZIONE TIPICA MURO GIUNTO DI COSTRUZIONE VERTICALE DEL MURO
SEZIONE PARAPETTO
INTERSEZIONE MUROANGOLO MURO
PRECEDENTE NUOVO
TUTTA L'ARMATURA SARA'
CONTINUA ATTRAVERSO IL GIUNTO
SOVRAPPOSIZIONE
MASSIMO
M A
S S
IM
O
ABBREVIAZIONI
SEZIONE A-A
SEZIONE B-B TIPICO
MASSIMO
MINIMO, TIPICO
PARTICOLARI TIPICI ARMATURA MURI
MASSIMO MASSIMO
NON IN SCALA
TUTTE LE ARMATURE VETRICALI ED ORIZZONTALI NEI MURI DI SPESSORE DI
250mm E 200mm SARANNO BARRE Ø16 SPAZIATE RISPETTIVAMNTE A 350mm E
400mm IN ASSE. GLI SPEZZONI DELLA FONDAZIONE SARANNO UGUALI ALLE
ARMATURE VERTICALI DEL MURO.
L'ARMATURA INDICATA E' SOLO PER SCOPO ILLUSTRATIVO. L'ARMATURA
EFFETTIVA RICHIESTA SARA' IN ACCORDO CON LA SEZIONE MURARIA
APPLICABILE.
PER I MURI SENZA APERTURE, X E' LA LUNGHEZZA TOTALE DEL MURO.
NELLA DETERMINAZIONE DELLA LUNGHEZZA X, LE PENETRAZIONI CON UN'AREA
DI APERTURA MINORE DI 0.5m2 SARANNO IGNORATE. LE BARRE ORIZZONTALI E
VERTICALI 4- Ø16 SI ESTENDERANNO 600mm OLTRE IL BORDO DELL'APERTURA.
LE BARRE DIAGONALI SARANNO LUNGHE 1000mm. LE BARRE SARANNO
POSIZIONATE AD OGNI LATO (2 PER OGNI FACCIA) DELL'APERTURA E
DIAGONALMENTE AD OGNI ANGOLO.
PROVVEDERE BARRE DIAGONALI 4- Ø16x1000 AGLI ANGOLI QUANDO X > 500
PER L'ARMATURA RICHIESTA VEDERE I PARTICOLARI TIPICI DELLE ARMATURE
DEI MURI.
X DENOTA LA LUNGHEZZA ORIZZONTALE DEL SEGMENTO DI PARETE.
PROVVEDERE AMMORSATURE LUNGHE 300mm A 600mm DI INTERASSE. I GIUNTI DI
COSTRUZIONE NON SARANNO POSIZIONATI PIU' VICINO DI 0.15 X DAL BORDO DEL MURO.
2. COORDINARE LE APERTURE PER I CANALI CON I DISEGNI MECCANICI.
SOVRAPPORRE LE GIUNZIONI NELLE ARMATURE VERTICALI SARA' PERMESSO
SOLAMENTE NELLE POSIZIONI MOSTRATE NEI PARTICOLARI DI SEZIONE RIFERITI ALLE
PIANTE. SOVRAPPORRE LE GIUNZIONI NELLE ARMATURE ORIZZONTALI SARA'
CONSENTITA A META' DISTANZA TRA PARETI INTERSECANTI. SFALSARE LE
SOVRAPPOSIZIONI DI 42 DIAMETRI DELLA BARRA A RICORSI ALTERNATI. PROVVEDERE
LUNGHEZZE DI SOVRAPPOSIZIONE DEI GIUNTI PARI A 42 DIAMETRI DELLA BARRA, SE
NON ALTRIMENTI INDICATO.
NOTE DEL FOGLIO:
NOTE:
1.
NOTE DI RIFERIMENTO:
STAFFE Ø10, SPAZIATE IN MODO UGUALE SIA VERTICALMENTE CHE ORIZZONTALMENTE
CON DISTANZA NON MAGGIORE DEL DOPPIO DELLA SPAZIATURA DELLE BARRE VERTICALI
, IN MODO DI AVERE UN MINIMO DI 6 STAFFE PER METRO QUADRATO DI MURO.
/ BARRE DI ARMATURA IN ACCIAIO
/ MURO IN CALCESTRUZZO
3. L'APPALTATORE DOVRA' POSIZIONARE I GIUNTI DI COSTRUZIONE VERTICALI DEI MURI
TRA DUE GETTI SUCCESSIVI DI CALCESTRUZZO IN MODO DA EVITARE FESSURAZIONI NEL
MURO.
64x * BARRE
MINIMO
t VARIE, VEDERE
PIANTA
LUNGO 600mm
X = LUNGHEZZA TOTALE DEL MURO
t = SPESSORE MURO
DIA (*) = DIAMETRO
/ NOTE DEI MATERIALI
032001.W01 STEEL REINFORCING BARS
033000.A04 CONCRETE WALL
032001.W01
032001.W01032001.W01
032001.W01
032001.W01 032001.W01
032001.W01
032001.W01
ELEVATION
B B
AA
X X
50 MAXIMUM
64xBAR Ø, MINIMUM
X
FOUNDATION DOWELS,
TYP
032001.W01032001.W01
X
032001.W01
NO SCALE /
TYPICAL WALL REINFORCING DETAILS
033000.A04032001.W01
032001.W01 Ø12/100
032001.W01
X ≤ 250mm
WALL CORNER
250mm < X ≤ 500mm
032001.W01
Ø12/100 032001.W01
032001.W01
Ø12/100 032001.W01
X
032001.W01 Ø12/100
200200
Ø12/100 032001.W01
0.15X
X > 1000mm
MAXIMUM
MAXIMUM
500 MAXIMUM
CL
032001.W01
WALL INTERSECTION
032001.W01
032001.W01
033000.A04
032001.W01
TYPICAL WALL SECTION
033000.A04 t VARIES, SEE PLAN
033000.A04
VERTICAL WALL CONSTRUCTION JOINT
032001.W01
NEWPREVIOUS
ALL REINFORCING SHALL BE
CONTINUOUS ACROSS JOINTS
032001.W01
600mm LONG
032001.W01 2-Ø20
032001.W01
PARAPET WALL SECTION
SEE PLAN
033000.A04
033000.A04
SECTION A-A
SECTION B-B
x/2
TYPICAL
ABBREVIATIONS:
X = TOTAL LENGTH OF WALL
t = WALL THICKNESS
MINIMUM, TYPICAL
ALL VERTICAL AND HORIZONTAL WALL REINFORCEMENT IN 250 MM AND 200 MM
THICK WALLS SHALL BE Ø16 BARS AT 350 MM AND 400 MM ON CENTER,
RESPECTIVELY. FOUNDATION DOWELS TO MATCH VERTICAL WALL
REINFORCING.
REINFORCING SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY. ACTUAL
REQUIRED REINFORCING SHALL BE IN ACCORDANCE WITH THE APPLICABLE "X"
WALL SECTION.
FOR WALLS WITHOUT OPENINGS, X IS THE TOTAL LENGTH OF WALL.
WHEN DETERMINING LENGTH X, PENETRATIONS HAVING AN OPENING AREA
SMALLER THAN 0.5 SQUARE METER SHALL BE IGNORED. 4- Ø16 HORIZONTAL AND
VERTICAL BARS SHALL EXTEND 600 MM BEYOND EDGE OF OPENING. DIAGONAL
BARS SHALL BE 1000 MM LONG. BARS SHALL BE PROVIDED ON EACH SIDE (2
EACH FACE) OF OPENING AND DIAGONALLY AT EACH CORNER.
PROVIDE 4- Ø16x1000 DIAGONAL BARS AT CORNERS OF OPENINGS WHEN X > 500.
SEE TYPICAL WALL REINFORCING DETAILS FOR REQUIRED REINFORCING.
X DENOTES HORIZONTAL LENGTH OF WALL SEGMENT.
PROVIDE 300 MM LONG KEYS AT 600 MM ON CENTERS. CONSTRUCTION JOINTS
SHALL NOT BE LOCATED CLOSER THAN 0.15X FROM A WALL EDGE.
2. COORDINATE OPENINGS FOR DUCTWORK WITH MECHANICAL DRAWINGS.
LAP SPLICES IN THE VERTICAL REINFORCING SHALL BE PERMITTED ONLY AT THE
LOCATIONS SHOWN IN THE SECTIONAL DETAILS REFERENCED TO THE PLANS. LAP
SPLICES IN THE HORIZONTAL REINFORCING SHALL BE PERMITTED MIDWAY BETWEEN
INTERSECTING WALLS. STAGGER SPLICES 42 x BAR DIAMETER IN ALTERNATE LAYERS.
PROVIDE LAP SPLICE LENGTHS = 42 X BAR DIAMETER UNLESS ONTHERWISE NOTED.
NOTES:
1.
Ø10 TIES, EQUALLY SPACED VERTICALLY AND HORIZONTALLY WITH DISTANCE
BETWEEN TIES NOT MORE THAN TWICE THE VERTICAL BAR SPACING,
PRODUCING A MINIMUM OF 6 TIES PER SQUARE METER OF WALL.
500mm < X ≤ 1000mm
DIA (Ø) = DIAMETER
MAXIMUM MAXIMUM
3. THE CONTRACTOR SHALL LOCATE VERTICAL WALL CONSTRUCTION JOINTS BETWEEN
TWO SUCCESSIVE CONCRETE POURS AND AS NEEDED TO PREVENT CRACKING IN THE
WALL.
4-Ø24 6-Ø24 10 BARS
4 BARS
4 BARS
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
1 : 1
T Y
P
IC
A L
W A
LL
R
E
IN
F O
R C
IN
G
D E
T A
IL
S
SE005
CA
CMG FMN RDS
NO SCALE
P A
R T
IC
O
LA
R
I T
IP
IC
I A
R M
A T
U R
A M
U R
I
14024707
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A B C D E F
C1
SE501A
1258560605017460128559150125
-600
-600
-600
C2
SE501A
B2
SE501A
033000.A04
033000.A04
033000.A04
033000.A04
033000.A04
033000.A04
033000.B01
033000.B01
033000.B01
033000.B01
033000.B01
033000.B01
033000.B01
033000.B01 033000.B01
033000.A04
033000.A06
F-4 033000.A06
F-4 033000.A06
033000.A04
033000.A04 033000.A04
033000.A04
033000.A04
7150 2000
1600 6050
8355 2935 6170
F-4 033000.A06
B1
SE501A
A2
SE502A
-50 -50
A1
SE501A
-25
033000.A04
F-4 033000.A06
033000.A06 F-3
F-3
F-2 033000.A06
F-2 033000.A06
F-1 033000.A06
F-1 033000.A06
F-1 033000.A06
F-1 033000.A06
F-1 033000.A06
F-1 033000.A06
F-5 033000.A06
T-1 033000.A06
T-1 033000.A06
T-1 033000.A06
T-2 033000.A06
T-2 033000.A06
C1
SE501A
A2
SE502A
A1
SE502A
D2
SE502A
D1
SE502A
SE502A
B2
A1
SE502A
A1
SE502A A1
SE502A
A1
SE502A
B1
SE501A
SIM
C T J
C T J
C T J
C T J
C T J
C T J
C T J
C T J
C J
C T J
CTJCTJCTJCTJCTJ CTJ CTJ
C T J
CTJ CTJC
T J
C J
C T J
C T J
CTJ
CTJ
C T J
C T J
CTJ CTJ CTJ CTJ
CTJ CTJ CTJ
C T J
C T J
C T J
C T J
C T J
C T J
C T J
C T J
C T J
C T J
CTJ CTJ
C T J
CTJCTJ
CTJ
CTJ
CJ
12 kPa (250 PSF)
6 kPa (125 PSF)
9.6 kPa (200 PSF)
7.2 kPa (150 PSF)
7.2 kPa (150 PSF)
7.2 kPa (150 PSF)
C1
SE501A
SIM
C1
SE510A
SEE DETAIL C1/C-503
FOR PIPE BOLLARD
VEDERE PARTICOLARE
C1/C-503 PER DISSUASORE
TUBOLARE
A4
SE502A
(24.875m)
(24.875m)
(24.875m)
(24.875m)
(24.875m)
MARK
FOUNDATION SCHEDULE
TABELLA FONDAZIONI
SIMBOLO
SIZE (mm)
DIMENSIONE
DEPTH (mm)
PROFONDITA’
F-1 800 x CONT. 450
REINFORCING
ARMATURA
5-Ø14 LONG. T & B w/ Ø14/250 CLOSED TIES
REMARKS
ANNOTAZIONI
F-2 1000 x CONT. 450 6-Ø14 LONG. T & B w/ Ø14/250 CLOSED TIES -
F-3 1200 x CONT. 450 7-Ø14 LONG. T & B w/ Ø14/250 CLOSED TIES -
F-4 1500 x CONT. 450 9-Ø14 LONG. T & B w/ Ø14/250 CLOSED TIES -
F-5 3300 x 4135 450
9-Ø14 (PLUS F-4) LONG. T & B FOR LONG
SPAN AND 18-Ø20 LONG. T & B FOR SHORT
SPAN
STAFFE CHIUSE
T-1 450 450 3-Ø20 LONG. T & B w/ Ø10/200 CLOSED TIES SEE SHEET SE501A
PER LATO CORTO
T-2 600 450 6-Ø20 LONG. T & B w/ Ø10/200 CLOSED TIES SEE SHEET SE501A
VEDI FOGLIO
TOP OF FOOTING ELEVATION (mm)
QUOTA SUPERIORE DELLA
FONDAZIONE
-1550
-1550
-1550
-1550
-1550
-1550
-1550
VEDI FOGLIOSTAFFE CHIUSE
STAFFE CHIUSE
STAFFE CHIUSE
STAFFE CHIUSE
PER LATO LUNGO
STAFFE CHIUSE
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
As indicated
F O U N D A T
IO
N /S
LA
B P
LA
N
SE100A
CA
CMG FMN RDS
1 : 100 B1
FOUNDATION/SLAB PLAN
NOTES:
SHEET NOTES:
NOTE:
NOTE DEL FOGLIO:
N
TRUE
NORTH
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
KEY PLAN
A
PIANTA FONDAZIONI/SOLETTA
MATERIAL NOTES / NOTE DEI MATERIALI
033000.A04 CONCRETE WALL / MURO IN CALCESTRUZZO
033000.A06 CONCRETE FOOTING / PLINTO IN CALCESTRUZZO
033000.B01 CONCRETE SLAB / SOLETTA IN CALCESTRUZZO
5. SEE THIS SHEET FOR FOUNDATION SCHEDULE.5. VEDERE QUESTO FOGLIO PER TABELLA FONAZIONI.
2. SEE SHEET SE002 FOR CONCRETE CONSTRUCTION NOTES.
1. SEE SHEET SE001 FOR GENERAL NOTES.
4. SEE SHEET SE005 FOR TYPICAL WALL REINFORCING DETAILS.4. VEDERE FOGLIO SE005 PER I PARTICOLARI TIPICI ARMATURA MURI.
3. SEE SHEET SE004 FOR TYPICAL SLAB DETAILS.3. VEDERE FOGLIO SE004 PER I PARTICOLARI TIPICI SOLETTA
KEY NOTES:NOTE DI RIFERIMENTO:
1. 150mm CONCRETE SLAB WITH Ø10/250 EACH WAY.1. SOLETTA IN CLS DA 150mm CON Ø10/250 NELLE DUE DIREZIONI.
00 00
2. 200mm CONCRETE SLAB WITH Ø10/250 EACH WAY.2. SOLETTA IN CLS DA 200mm CON Ø10/250 NELLE DUE DIREZIONI.
3. 200mm CONCRETE WALL. SEE SHEETS SE005, SE201A, AND SE202A FOR REINFORCING.
3. MURO IN CLS DA 200mm. VEDERE FOGLI SE005, SE201A E SE202A
PER ARMATURA.
4. 250mm CONCRETE WALL. SEE SHEETS SE005, SE201A, AND SE202A FOR REINFORCING.
4. MURO IN CLS DA 250mm. VEDERE FOGLI SE005, SE201A E SE202A
PER ARMATURA.
NOTE: NOTES:
5. SEE MECHANICAL DRAWINGS FOR CONCRETE PAD
DIMENSIONS AND REINFORCEMENT.
5. VEDERE DISEGNI MECCANICI PER DIMENSIONI ED ARMATURAPEDANA
IN CLS.
6. GRAVITY FLOOR LOADS AS NOTED. ALL OTHER AREAS
4.8 kPa (100 PSF).
6. CARICHI ACCIDENTALI DEL PIANO COME INDICATI. TUTTE LE
ALTRE AREE 4.8 kPa (100PSF)
P
IA
N
TA
F O N D A
ZI
O N I/S
O
LE
T T A
2. VEDERE FOGLIO SE002 PER LE NOTE DI COSTRUZIONE DEL CALCESTRUZZO.
1. VEDERE FOGLIO SE001 PER LE NOTE GENERALI.
6. SEE SHEETS CG101, CG102, CG103, AND CG104 FOR SITE GRADING.6. VEDERE FOGLI CG101, CG102, CG103 E CG104 PER I LIVELLAMENTI DEL SITO.
14024708
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A B C D E F
9150 12855 17460 6050 8560 125
D E C K S P A N
D E C K S P A N
IPE 400, TYP
033000.A04
033000.A04
D E C K S P A N
L U
C E
IM
P
A L C
A T
O
D E C K S P A N
20002000
IP
E
IP
E
5 SPAZI UGUALI
54325
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
IP
E
3500 35003525 3500 3500 3500 3500 29355 EQUAL SPACES = 16510
2 EQUAL SPACES = 5855
L x8
L x8
L x8
051200.A01
IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360
IPE360
IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360
IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360 IPE360
HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200
HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200 HEA200
051200.E01 L100x7, TYP. UNLESS
NOTED OTHERWISE
SE NON DIVERSAMENTE
INDICATO
L100x10 L100x14
L100x10
033000.A04
033000.A04 200033000.A04
L100x7, TYP. UNLESS
NOTED OTHERWISE
C1
SE510A
C1
SE510A
C1
SE510A
051200.E01
C1
SE510A
SIM
SIMC1
SE510A
051200.E01
051200.E01
051200.E01
SE510A
B1 TYP
H E A
B2
SE510A
B4
SE510A
A1
SE510A
A1
SE510A
SIM
A2
SE510A
D1
SE511A
D1
SE511A
SE510A
B1 SIM
051200.E01 L100x10 L100x10
051200.E01 L100x10 051200.E01
L U
C E
IM
P
A L C
A T
O
L U
C E
IM
P
A L C
A T
O
L U
C E
IM
P
A L C
A T
O
SE NON DIVERSAMENTE
INDICATO
2 SPAZI UGUALI
IPE360
IPE360
H E A
IPE360
IPE360
IPE360
HEA200
HEA200
HEA200
HEA200
L x8
IPE300
H E A
HEA200IPE300 HEA200 HEA200 HEA200 HEA200 IPE300 IPE300 HEA200
HEA200
HEA200 HEA200 IPE300 IPE300 HEA200 HEA200
HEA200
D2
SE511A
B1
SE511A
B E L O W
S O
T T
O
B1
SE511A
SIM
SIM
B4
SE511A
B4
SE511A
.A
.A
051200.A01
.A
.A
033000.A04
051200.A01
051200.A01
.A
033000.A04
051200.A01
A1
SE511A
D2
SE511A
SIM
D2
SE511A
SIM EACH SIDES
SU ENTRAMBI I LATI
051200.A01
B4
SE510A
SIM
(2
(2
(2
(2
(2
(2
(2
A4
SE511A
(2
SE511A
D3
SE511A
D3 SIM
SE511A
D3 SIM
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
1 : 100
R O O F T O P C H O R D F R A M
IN
G P
LA
N
SE123A
CA
CMG FMN RDS
1 : 100 A1
ROOF TOP CHORD FRAMING PLAN
NOTES:
SHEET NOTES:
NOTE:
NOTE DEL FOGLIO:
N
TRUE
NORTH
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
KEY PLAN
A
MATERIAL NOTES / NOTE DEI MATERIALI
033000.A04 CONCRETE WALL / MURO IN CALCESTRUZZO
051200.A01 STEEL BEAM / TRAVE IN ACIAIO
051200.E01 STEEL ANGLE / ANGOLARE IN ACCIAIO
1. SEE SHEET SE001 FOR GENERAL NOTES.1. VEDERE FOGLIO SE001 PER LE NOTE GENERALI.
2. SEE SHEET SE002 FOR STEEL CONSTRUCTION NOTES.2. VEDERE FOGLIO SE002 PER LE NOTE DI COSTRUZIONE DELL’ACCIAIO.
P
IA
N T
A I N
T E
L A
IA
T
U R
A S
U P
E R
IO
R
E C
O P
E R
T U
R A
PIANTA INTELAIATURA SUPERIORE COPERTURA
KEY NOTES:NOTE DI RIFERIMENTO: 0000
1. ESTRATTORE FUMI. VEDI DISEGNI MECCANICI 1. SMOKE EXHAUST FAN. SEE MECHANICAL DRAWINGS.
14024709
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
SLAB PLAN
TOP OF WALL
TOP OF FOOTING
-1550
PARAPET RIDGE
033000.A04
033000.A06
10750 10750
ESTRADOSSO MURO
PIANTA SOLETTA
ESTRADOSSO
FONDAZIONE
COLMO PARAPETTO
2 2
.2
SLAB PLAN
ABCDEF
TOP OF WALL
TOP OF FOOTING
-1550
033000.A04
033000.A06
9150128551746060508560
ESTRADOSSO MURO
PIANTA SOLETTA
ESTRADOSSO
FONDAZIONE
. .2 2 . . . . . . . . . ..2 2 2 2 2 2 2 2 2 2 2
.5
.6
.6
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
1 : 100
W A
LL
R E
IN
F O R C E M E N T E
LE
V A T
IO
N S
SE201A
CA
CMG FMN RDS
1 : 100 C1
NORTH ELEVATION
1 : 100 B1
EAST ELEVATION
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
NOTES:
SHEET NOTES:
NOTE:
NOTE DEL FOGLIO:
PROSPETTO NORD
PROSPETTO EST
1. SEE SHEET SE001 FOR GENERAL NOTES.1. VEDERE FOGLIO SE001 PER LE NOTE GENERALI.
2. SEE SHEET SE002 FOR CONCRETE CONSTRUCTION NOTES.2. VEDERE FOGLIO SE002 PER LE NOTE DI COSTRUZIONE DELL’ACCIAIO.
3. SEE SHEET SE005 FOR TYPICAL WALL REINFORCING DETAILS.3. VEDERE FOGLIO SE005 PER I PARTICOLARI TIPICI ARMATURA MURI.
KEY NOTES:NOTE DI RIFERIMENTO:
1. SEE SHEET SE005 FOR ADDED WALL REINFORCING.1. VEDERE FOGLIO SE005 PER ARMATURA ADDIZIONALE AI MURI.
00 00
MATERIAL NOTES / NOTE DEI MATERIALI
033000.A04 CONCRETE WALL / MURO IN CALCESTRUZZO
033000.A06 CONCRETE FOOTING / PLINTO IN CALCESTRUZZO
P R O S P E T T I A
R M A T U R E M U R I
2. SEE SHEET SE005 FOR REQUIRED WALL SEGMENT REINFORCING.2. VEDERE FOGLIO SE005 PER LE ARMATURE RICHIESTE SU PORZIONI DI MURO.
3. SEE SHEET SE005 FOR TYPICAL WALL REINFORCING.3. VEDERE FOGLIO SE005 PER LE ARMATURE TIPICHE DEI MURI.
4. SEE SHEETS ES101 AND ES403 FOR DUCT BANK LOCATIONS.
COORDINATE FINAL LOCATION WITH POSITION OF ELECTRICAL SWITCH
GEAR IN BUILDING.
4. VEDERE FOGLI ES101 E ES403 PER L’UBICAZIONE DEI CAVIDOTTI.
COORDINARE L’UBICAZIONE FINALE CON LA POSIZIONE DEL QUADRO
ELETTRICO NELL’EDIFICIO.
5. VERTICAL WALL REINFORCING LAP WITH DOWELS 64 BAR DIAMETERS,
TYPICAL.
5. SOVRAPPORRE LE ARMATURE VERTICALI DEI MURI CON SPEZZONI
LUNGHI 64 DIAMETRI, TIPICO.
6. HORIZONTAL WALL REINFORCING LAP 64 BAR DIAMETERS. LOCATE LAPS
AWAY FROM INTERSECTING WALLS.
6. SOVRAPPORRE LE ARMATURE ORIZZONTALI DEI MURI PER UNA
LUNGHEZZA DI 64 DIAMETRI. POSIZIONARE LE SOVRAPPOSIZIONI
LONTANO DALLE INTERSEZIONI DEI MURI.
14024710
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
1 2 3
TOP OF WALL
TOP OF FOOTING
-1550
PARAPET RIDGE
B.O. CONC
B.O. OPNG
B1
SE502A
033000.A04
033000.A06
10750 10750
ESTRADOSSO MURO
PIANTA SOLETTA
ESTRADOSSO
FONDAZIONE
COLMO PARAPETTO
2 2
SLAB PLAN
A B C D E F
DEPRESSED SLAB
-600
TOP OF WALL
TOP OF FOOTING
-1550
033000.A04
033000.A06
9150 12855 17460 6050 8560
ESTRADOSSO MURO
PIANTA SOLETTA
ESTRADOSSO
FONDAZIONE
SOLETTA RIBASSATA
3. . .2 2 2
A4
SE502A
44 4
.5
.6
U A
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
1 : 100
W A
LL
R E
IN
F O R C E M E N T E
LE
V A T
IO
N S
SE202A
CA
CMG FMN RDS
1 : 100 C1
SOUTH ELEVATION
1 : 100 B1
WEST ELEVATION
NOTES:
SHEET NOTES:
NOTE:
NOTE DEL FOGLIO:
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
PROSPETTO SUD
PROSPETTO OVEST
1. SEE SHEET SE001 FOR GENERAL NOTES.
2. SEE SHEET SE002 FOR CONCRETE CONSTRUCTION NOTES.
3. SEE SHEET SE005 FOR TYPICAL WALL REINFORCING DETAILS.
KEY NOTES:NOTE DI RIFERIMENTO:
1. SEE SHEET SE005 FOR ADDED WALL REINFORCING.
00 00
MATERIAL NOTES / NOTE DEI MATERIALI
033000.A04 CONCRETE WALL / MURO IN CALCESTRUZZO
033000.A06 CONCRETE FOOTING / PLINTO IN CALCESTRUZZO
1. VEDERE FOGLIO SE001 PER LE NOTE GENERALI.
2. VEDERE FOGLIO SE002 PER LE NOTE DI COSTRUZIONE DELL’ACCIAIO.
3. VEDERE FOGLIO SE005 PER I PARTICOLARI TIPICI ARMATURA MURI.
1. VEDERE FOGLIO SE005 PER ARMATURA ADDIZIONALE AI MURI.
P R O S P E T T I A
R M A T U R E M U R I
2. SEE SHEET SE005 FOR REQUIRED WALL SEGMENT REINFORCING.
3. SEE SHEET SE005 FOR TYPICAL WALL REINFORCING.
4. SEE SHEETS ES101 AND ES403 FOR DUCT BANK LOCATIONS.
COORDINATE FINAL LOCATION WITH POSITION OF ELECTRICAL SWITCH
GEAR IN BUILDING.
2. VEDERE FOGLIO SE005 PER LE ARMATURE RICHIESTE SU PORZIONI DI MURO.
3. VEDERE FOGLIO SE005 PER LE ARMATURE TIPICHE DEI MURI.
4. VEDERE FOGLI ES101 E ES403 PER L’UBICAZIONE DEI CAVIDOTTI.
COORDINARE L’UBICAZIONE FINALE CON LA POSIZIONE DEL QUADRO
ELETTRICO NELL’EDIFICIO.
5. VERTICAL WALL REINFORCING LAP WITH DOWELS 64 BAR DIAMETERS,
TYPICAL.
5. SOVRAPPORRE LE ARMATURE VERTICALI DEI MURI CON SPEZZONI
LUNGHI 64 DIAMETRI, TIPICO.
6. HORIZONTAL WALL REINFORCING LAP 64 BAR DIAMETERS. LOCATE LAPS
AWAY FROM INTERSECTING WALLS.
6. SOVRAPPORRE LE ARMATURE ORIZZONTALI DEI MURI PER UNA
LUNGHEZZA DI 64 DIAMETRI. POSIZIONARE LE SOVRAPPOSIZIONI
LONTANO DALLE INTERSEZIONI DEI MURI.
14024711
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
S S
A T
C O
M R
E
LA
Y P
A D
S A
N D
F A
C
IL
IT
Y
1118648
N A
V A
L A
IR
S
T A
T
IO
N
II
S
IG
O N
E
LL
A , S
IC
IL
Y , I
T A
LY
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A T
LA
N
T
IC
LA
N
T C
A P
IT
A
L
IM
P R
O V
E M
E N
T S
N O
R F
O
LK
, V
IR
G
IN
IA
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
ROGERS, LOVELOCK & FRITZ, INC
LICENSE # AA C000564 # EB 0000629
Architecture Engineering
4750 New Broad Street Orlando, FL www.rlfae.com
Interior Design
D V
IE
W R O O F F R A M
IN
G
SE203A
CA
CMG FMN RDS
SOUTHWEST ELEVATION
NORTHEAST ELEVATION
V
IS
T A
D
I N
T E
L A
IA
T
U R
E C
O P
E R
T U
R A
PROSPETTO SUD-OVEST
PROSPETTO NORD-EST
14024712
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
A
TOP OF FOOTING
-1550
GRID
PIANTA SOLETTA
ESTRADOSSO
FONDAZIONE
SEE PLANS
033000.A06
033000.B01
033000.J05
033000.A04
TIPICO
Ø16/350
032001.W01 Ø10/350
033000.W01
EQUAL EQUAL
0mm, TYP
E X
C A
V A
T E
FINISHED GRADE
TERRENO FINITO
VEDERE PIANTE
SEE PLANS
S O V R A P P O S
IZ
IO
N E
VEDERE PIANTE
UGUALE UGUALE
SLAB PLAN
DEPRESSED SLAB
-600
TOP OF FOOTING
-1550
GRID
033000.A04
033000.J05
033000.A06
PIANTA SOLETTA
ESTRADOSSO
FONDAZIONE
SEE PLANS
033000.B01SOLETTA RIBASSATA
0mm, TYP
TIPICO
0mm, TYP
TIPICO
Ø16/350 032001.W01
Ø10/350 032001.W01
750 750
VEDERE PIANTE
SLAB PLAN
DEPRESSED SLAB
-600
TOP OF FOOTING
-1550
CENTERLINE WALL
MEZZERIA DEL MURO
SOLETTA RIBASSATA
ESTRADOSSO
FONDAZIONE
400 400
033000.A06
033000.A04
033000.B01
033000.J05
033000.B01
033000.J05
SEE PLANS
PIANTA SOLETTA
Ø16/400
Ø10/400 033000.W01
033000.W01
VEDERE PIANTE
SLAB PLAN
DEPRESSED SLAB
-600
TOP OF FOOTING
-1550
CENTERLINE WALL
033000.A04
033000.B01
033000.J05
033000.A06
SEE PLANS
033000.B01
033000.J05
EQUAL EQUAL
Ø16/400
Ø10/400
033000.W01
033000.W01
MEZZERIA DEL MURO
SOLETTA RIBASSATA
ESTRADOSSO
FONDAZIONE
PIANTA SOLETTA
VEDERE PIANTE
SEE PLANS
VEDERE PIANTE
UGUALE UGUALE
SLAB PLAN
TOP OF FOOTING
-1550
033000.A04
033000.B01
033000.B01
033000.A07 F-5
COORDINATE WITH ARCHITECTURAL DRAWINGS
COORDINARE CON I DISEGNI ARCHITETTONICI
SE502A
A1 SIM
750 974 1576
SEE SHEET SE004 FOR ADDED REINFORCING AT
EXTERIOR DOOR OPENING
VEDERE FOGLIO SE004 PER ARMATURA ADDIZIONALE ALLE
APERTURE DELLE PORTE ESTERNE
ESTRADOSSO
FONDAZIONE
PIANTA SOLETTA
SOVRAPPOSIZIONE
S O V R A P P O S
IZ
IO
N E
033000.A04 TYP HORIZONTAL
REINFORCING
ARMATURA
ORIZZONTALE TIPICA
033000.W01
OUTSIDE CORNER
BARS SAME SIZE AND
NUMBER AS
HORIZONTAL BARS
BARRE ALL’ANGOLO
ESTERNO DELLA
STESSE DIMENSIONI
E NUMERO
TIPICO
CORNER
ANGOLI
LAP
LA
P
0mm, TYP
0mm, TYP
0m m
, T Y
P
LA
P
S O V R A P P O S
IZ
IO
N
ETIPICO
INTERSECTIONS
INTERSEZIONI
T
IP
IC
O
033000.W01
033000.W01
TYP HORIZONTAL
REINFORCING
ARMATURA
ORIZZONTALE TIPICA
TYP HORIZONTAL
REINFORCING
ARMATURA
ORIZZONTALE TIPICA
50x100 KEYWAY
GIUNTO A CHIAVE
033000.A07
033000.A07
FOUNDATIONTIE BEAM
40 x BAR Ø
FONDAZIONE
BARRE
032001.W01
SEE SCHEDULE
ON SHEET SE100A
033000.A06
STANDARD 90 DEGREE
HOOK OR CONTINUE
REINFORCING THROUGH
MEMBER OR FOUNDATION
GANCIO STANDARD A 90 GRADI
O ARMATURA CONTINUA
ATTRAVERSO GLI ELEMENTI
O FONDAZIONE
ROUGHENED SURFACE,
5mm AMPLITUDE (MIN)
SUPERFICIE IRRUVIDITA,
5mm DI AMPIEZZA (MIN)
TRAVE DI COLLEGAMENTO
032001.W01
SEE SCHEDULE
ON SHEET SE100A
VEDERE TABELLA SU
FOGLIO SE100A
032001.W01
SEE SCHEDULE
ON SHEET SE100A
T-1 T-2
VEDERE TABELLA SU
FOGLIO SE100A
VEDERE TABELLA SU
FOGLIO SE100A
U A
S S
A T
C O
M R
E