N62470-09-R9034_Part02-LS.pdf
PDF 698 KB Posted
- Solicitation number
- N33191-15-R-0802
About this file
Part 02 LS
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A B C E FD
COMM EXT
SECURE ROOM
IT-2 OPS
OFFICE
CORR
BREAK
CONFERENCE
CORR
VEST
TLT F
107 TLT M
STORAGE / SHOP
HVAC
BOILER
IT-1 RACK ROOM
CORR
ELEC
STOR
CORR
JAN
FEC
FE
FE
FE
FE
FE
FE
FE FE
0A
0D
0B0C
68 (INCHES)
3 (IEM)
46 (INCHES)
1 (IEM)
FE
FEC
46 (INCHES)
1 (IEM)
FE
NOTES:
SHEET NOTES:
NOTE:
NOTE DEL FOGLIO:
LEGENDA PIANO DI SICUREZZA
LIFE SAFETY LEGEND
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
TRAMEZZO REI 60
TRAMEZZO REI 120
1 HOUR SMOKE BARRIER
TRAMEZZO REI 60
2 HOUR SMOKE BARRIER
TRAMEZZO REI 120
FIRE SPRINKLER
SPRINKLER ANTINCENDIO
EXIT LIGHT
LUCIE INDAZIONE USCITA
SMOKE DETECTOR
RIVELATORE DE FUMO
FIRE ALARM SPEAKER
ALTOPARLANTE ALLARME INCENDIO
STOBE LIGHT
LUCE DELLO STROBOSCOPIO
DUCT SMOKE DETECTOR
RIVELATORE DI FUMO DA CANALE
COMBINATION SPEAKER STROBE
COMBINAZIONE
ALTOPARLANTE/LAMPEGGIANTE
MANUAL PULL STATION
PULSANTE MANUALEP
HEAT DETECTOR
RIVELATORE DE CALORE
FIRE EXTINGUISHER TABLE
TAVOLA DEGLI ESTINTORI ANTINCENDIO
TYPE HAZARD QTY
TIPO PERICOLO QUANTITA'
SECCO
CHIMICO
CLASS A/B
RATING
PORTATA
ROOM No.
NUMERO
STANZA
ROOM NAME
NOME STANZA
55A/233B;C
55A/233B;C CLASSE A/B
STORAGE/SHOP
HVAC
COMM EXT
IT-1 RACK ROOM
IT-2 OPS
ELECTRICAL ROOM
CORRIDOR
CORRIDOR
BOILER1
DRY
CHEMICAL
RO
RT
F B U
NO
M.
TE
N A
16616 E N G
D
NI E E R
OL V
SEAL
S
A
SFORP
E H C
I A L
OI N
OR L
T
U
AS
S
AT
C O
M R
EL
AY
P
AD
S
AN
D F
AC
IL
IT
Y
1118648
N
AV
AL
A
IR
S
TA
TI
O N
II
SI
G O
N
EL
LA
, S
IC
IL
Y, IT
AL
Y
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
A
TL
AN
TI
C
LA
N T
C
AP
IT
AL
IM
PR
O
VE
M
EN
TS
N
O R
FO
LK
, V
IR
G
IN
IA
D
EP
A R
TM
E
N T
O F
TH
E
N
AV
Y N
AV
AL
F A
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
As indicated
CO
MP
OS
IT
E
GR
OU
ND
F
LO
OR
P
LA
N
- L
IF
E
SA
FE
TY
GC100A
CA
BML MEC JL
PI
AN
TA
C
OM
PO
SI
TA
P
IA
NO
T
ER
RA
PI
AN
O
DI
S
IC
UR
EZ
ZA
14024657
1 : 100A1 COMPOSITE GROUND FLOOR PLAN - LIFE SAFETY
PIANTA COMPOSITA PIANO TERRA - PIANO DI SICUREZZA
N
TRUE
NORTH
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 3000 10000
KEY PLAN
A
SCALA GRAFICA (MILLIMETRI)
TRAVEL DISTANCE / DISTANZA D'ESODO
PATH OF EGRESS
VIA DI FUGA
DISTANCE
DISTANZA
(MM)
DISTANCE
DISTANZA
(FT DECIMALS)
0A 30,761 mm 100.92 0B 31,268 mm 102.59 0C 31,960 mm 104.85 0D 47,264 mm 155.07
A. REFER TO SHEET GC201 FOR CALCULATIONS AND GC202 FOR LIFE
SAFETY NOTES.
A. FARE RIFERIMENTO AL FOGLIO GC201 PER CALCOLI E GC202 PER NOTE
PIANO DI SICUREZZA.
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
WALLS
BUILDING MEMBER IBC/NFPA
DOORS/
WINDOWS
EXTERIOR WALLS
INTERIOR WALLS
LOAD BEARING
NON LOAD BEARING
LOAD BEARING
NON LOAD BEARING
SPECIAL ROOMS
ROOM PARTITIONS
WAYS OF EGRESS
ELECTRICAL WITH UPS
COMMUNICATIONS
JANITOR'S CLOSET
MECHANICAL
BOILER ROOM
RACK ROOM
OPS
SECURE ROOM
WALLS
STORAGE/SHOP
STRUCTURAL FRAME
FLOOR CONSTRUCTION
COLUMNS SUPPORTING ROOF
ROOF CONSTRUCTION
* HORIZONTAL STRUCTURE RATING WILL BE EQUIVALENT TO WALL RATING
DESIGNED PER MOST STRINGENT OF THE TWO CODES - NO CONFLICT
ANTICIPATED
0 HR
0 HR
0 HR
0 HR
0 HR
1 HR
0 HR
0 HR
0 HR
1 HR
45 MIN
1 HR
0 HR
1 HR
0 MIN
0 MIN
0 MIN
0 MIN
0 MIN
45 MIN
0 MIN
0 MIN
0 MIN
45 MIN
45 MIN
45 MIN
45 MIN
0 MIN
0 HR
0 HR
0 HR
WALLS
ITALIAN CODE
DOORS/
WINDOWS
0 0
0 0
0 0
0 0 0 0
60 45
120 120
WALLS
SOLUTION
DOORS/
WINDOWS
0 0
0 0
0 0
0 0 0 0
60 60
120 120
CONSTRUCTION
250MM CONCRETE WALL
200MM REINFORCED CONCRETE WALL W/ STUD & GWB
METAL STUD WALL W/ TWO LAYERS OF GWB
METAL STUD WALL W/ TWO LAYERS OF GWB
200MM REINFORCED CONCRETE & 200MM REINFORCED CONCRETE W/ STUD & GWB
200MM REINFORCED CONCRETE
METAL STUD WALL W/ TWO LAYERS OF GWB
200MM REINFORCED CONCRETE & 200MM REINFORCED CONCRETE W/ STUD & GWB
METAL STUD WALL W/ FOUR LAYERS OF GWB
200MM REINFORCED CONCRETE
200MM REINFORCED CONCRETE W/ STUD & GWB
200MM REINFORCED CONCRETE W/ STUD & GWB
200MM REINFORCED CONCRETE & 200MM REINFORCED CONCRETE W/ STUD & GWB
STEEL JOISTS/FABRICATED ROOF PANEL ASSEMBLY
CONCRETE W/ TILE-RUBBER-CARPET FLOORING
MURI
ELEMENTO DELL'EDIFICIO IBC/NFPA
PORTE/
FINESTRE
MURI ESTERNI
MURI INTERNI
PORTANTI
NON PORTANTI
PORTANTI
NON PORTANTI
LOCALI SPECIALI
TRAMEZZI STANZE
VIE DI USCITA
ELETTRICO CON UPS
COMUNICAZIONE
LOCALE DI SERVIZIO
MECCANICA
CENTRALE TERMICA
RACK ROOM
OPS
SECURE ROOM
MURI
STORAGE/SHOP
OSSATURA STRUTTURALE
COSTRUZIONE PAVIMENTO
PILASTRI A SUPPORTO COPERTURA
COSTRUZIONE DELLA COPERTURA
* LA CLASSE DI RESISTENZA DELLA STRUTTURA ORIZZONTALE SARA'
EQUIVALENTE ALLA CLASSE DI RESISTENZA DEL MURO
PROGETTATI PER LE PRESCRIZIONI PIU' RESTRITTIVE DEI DUE CODICI - NON SI
PREVEDE CONFLITTO
0 ORE
0 ORE
0 ORE
0 ORE
0 ORE
1 ORE
0 ORE
0 ORE
0 ORE
1 ORA
45 MIN
1 ORA
0 ORE
1 ORA
0 MIN
0 MIN
0 MIN
0 MIN
0 MIN
45 MIN
0 MIN
0 MIN
0 MIN
45 MIN
45 MIN
45 MIN
45 MIN
0 MIN
0 ORE
0 ORE
0 ORE
MURI
CODICE ITALIANO
PORTE/
FINESTRE
0 0
0 0
0 0
0 0 0 0
60 45
120 120
MURI
SOLUZIONE PROPOSTA
PORTE/
FINESTRE
0 0
0 0
0 0
0 0 0 0
60 45
120 120
COSTRUZIONE
MURO IN CLS ARMATO 250MM
MURO IN CLS ARMATO 200MM
PARETE IN MONTANTI METALLICI CON 2 STRATI DI GWB
PARETE IN MONTANTI METALLICI CON 2 STRATI DI GWB
MURO IN CLS ARMATO 200MM E MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB
MURO IN CLS ARMATO 200MM
PARETE IN MONTANTI METALLICI CON 2 STRATI DI GWB
MURO IN CLS ARMATO 200MM E MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB
PARETE IN MONTANTI METALLICI CON 4 STRATI DI GWB
MURO IN CLS ARMATO 200MM
MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB
MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB
MURO IN CLS ARMATO 200MM E MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB
TRAVETTI DI ACCIAIO/PANNELLI DI COPERTURA PREFORMATI
CLS CON PAVIMENTAZIONE IN PIASTRELLE-GOMMA-MOQUETTE
0 0
0 0 0 0
RO
RT
F B U
NO
M.
TE
N A
16616 E N G
D
NI E E R
OL V
SEAL
S
A
SFORP
E H C
I A L
OI N
OR L
T
U
AS
S
AT
C O
M R
EL
AY
P
AD
S
AN
D F
AC
IL
IT
Y
1118648
N
AV
AL
A
IR
S
TA
TI
O N
II
SI
G O
N
EL
LA
, S
IC
IL
Y, IT
AL
Y
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
A
TL
AN
TI
C
LA
N T
C
AP
IT
AL
IM
PR
O
VE
M
EN
TS
N
O R
FO
LK
, V
IR
G
IN
IA
D
EP
A R
TM
E
N T
O F
TH
E
N
AV
Y N
AV
AL
F A
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
1 : 1
LIF
E
SA
FE
TY
A
NA
LY
SI
S
GC201
CA
BML MEC JL
AN
AL
IS
I P
IA
NO
D I S
IC
UR
EZ
ZA
14024658
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
FACILITY IS TO BE SPRINKLERED THROUGHOUT
(SPRINKLERS NOT PROVIDED IN ELECTRICAL AND COOMUNCATION ROOMS PER
ITALIAN NORM).
DUE TO ANALYSIS AND INCORPORATION OF THE MOST STRINGENT ASPECTS OF
BOTH CODES, WE ANTICIPATE NO CONFLICTS.
PRIMARY OCCUPANTS ON BASE:
MILITARY
U.S. CODES REFERENCED:
NFPA 101 LIFE SAFETY CODE (2009)
INTERNATIONAL BUILDING CODE (2009)
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (2009)
U.S. OCCUPANT LOAD CALCULATIONS:
100 SF (9.3 SM) / PERSON PER BUSINESS OCCUPANCY
500 SF (46.4 SM) / PERSON PER STORAGE OCCUPANCY
(1) ITALIAN EGRESS MODULE = 60 CM (MIN 120 CM PER EXIT)
ITALIAN LAWS AND DECREES:
D.P.R. 503, 24TH JULY 1996
D.M. 236, 24TH JUNE 1989
D.M. 25TH AUGUST 1989
D.M. 19TH AUGUST 1996
D.M. 18TH MARCH 1998
CIRCOLARE 16, 15TH FEBRUARY 1951 OF THE MINISTRY OF INTERIOR
D.M. 30TH NOVEMBER 1983
ITALIAN CROWDING INDEXES:
Ns = 0.10 FOR OFFICES, STORAGE, AND SIMILAR Ns = 0.40 FOR COMMON AREAS Ns = 0.70 FOR CONCENTRATED USE AREAS
(1) ITALIAN EGRESS MODULE = 60 CM (MIN 120 CM PER EXIT)
ITALIAN OUTFLOW CAPACITY PER ITALIAN EGRESS MODULE (IEM):
50 PERSONS, GROUND FLOOR
37.5 PERSONS, FIRST FLOOR
NOTES:
L'EDIFICIO SARA' TOTALMENTE PROTETTO DA UN IMPIANTO SPRINKLER
(SPRINKLER NON PREVISTO NEI LOCALI ELETTRICI E COMUNICAZIONI IN BASE ALLE
NORME ITALIANE)
DATA L'ANALISI E L'INCORPORAZIONE DEI PIU' RIGOROSI ASPETTI DI ENTRAMBI I
CODICI, SI PREVEDE L'ASSENZA DI CONFLITTUALITA'
OCCUPANTI PRINCIPALI DELLA BASE:
MILITARI
CODICI DI RIFERMENTO U.S.:
NFPA 101 LIFE SAFETY CODE (2009)
INTERNATIONAL BUILDING CODE (2009)
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (2009)
INDICI STANDARD DI SUPERFICIE U.S.:
100 SF (9.3 MQ) / PERSONA CON ATTIVITA’ GESTIONALE
500 SF (46.4 MQ) / PERSONA ADDETTA AL MAGAZZINO
LEGGI E DECRETI ITALIANI:
D.P.R. 503, 24 LUGLIO1996
D.M. 236, 24 GIUGNO 1989
D.M. 25 AGOSTO 1989
D.M. 19 AGOSTO 1996
D.M. 18 MARZO 1998
CIRCOLARE 16, 15 FEBBRAIO 1951 DEL MINISTERO DEGLI INTERNI
D.M. 30 NOVEMBRE 1983
INDICI ITALIANI DI AFFOLLAMENTO:
Ns = 0.10 PER UFFICI, MAGAZZINI E SIMILI Ns = 0.40 PER AREE COMUNI Ns = 0.70 PER AREE DI USO CONCENTRATO
(1) MODULO DI USCITA ITALIANO = 60 cm (MIN 120 cm PER USCITA)
CAPACITA' DI DEFLUSSO SECONDO IL MODULO ITALIANO PER LE VIE DI USCITA (IEM):
50 PERSONE, PIANO TERRA
37.5 PERSONE, PRIMO PIANO
NOTE:
OCCUPANCY: MIXED OCCUPANCY, NON-SEPARATED USE
STORAGE/BUSINESS
BUSINESS: "B" (OFFICE) MODERATE-HAZARD,
IBC SEC 311.2
STORAGE - ORDINARY HAZARD,
NFPA 101, CH. 42
STORAGE: S-1 (STORAGE/MECHANICAL) MODERATE-HAZARD,
IBC SEC 311.2
STORAGE - ORDINARY HAZARD,
NFPA 101, CH. 42
REQUIRED SEPARATION OF OCCUPANTS (IBC TABLE 508.4): NONE
CONSTRUCTION TYPE:
TYPE II - B, FULLY SPRINKLERED, IBC TABLE 503 AND SEC 602
(NOT PROVIDED IN ELECTRICAL EQUIPMENT ROOMS)
ALLOWABLE BUILDING AREA (IBC TABLE 503):
ALLOWABLE GROSS AREA: 2,137 GSM (23,000 GSF)
GROUND FLOOR:
DESIGN GROSS AREA: 1,208 GSM (13,006 GSF)
EXTERIOR (HALF AREA): 2 GSM (21 GSF)
TOTAL GROSS AREA: 1,210 GSM (13,024 GSF)
GROUND FLOOR U.S. OCCUPANT LOAD:
ASSEMBLY:
56.6 SM / 1.4 SM/PER = 41 PEOPLE
BUSINESS:
852.2 SM / 9.3 SM/PER = 92 PEOPLE
STORAGE/MECHANICAL:
226.4 SM / 27.9 SM/PER = 9 PEOPLE
GROUND FLOOR PROVIDED EXIT UNITS CAPACITY
STORAGE HORIZONTAL:
46 @ 0.20" (0.38 CM): 230 PEOPLE
BUSINESS HORIZONTAL:
114 @ 0.20" (0.38 CM): 228 PEOPLE
BUILDING HEIGHT (IBC TABLE 503)
ALLOWABLE HEIGHT: 2 STORIES (16.8 M)
ACTUAL HEIGHT: 1 STORY (8.2 M)
STORAGE, ORDINARY HAZARD (IBC):
DEAD END CORRIDORS SHALL NOT EXCEED: 30M (100 FT)
COMMON PATH OF TRAVEL SHALL NOT EXCEED: 30M (100 FT)
MAX. TRAVEL DISTANCE TO AN EXIT: 122M (400 FT)
BUSINESS, ORDINARY HAZARD (IBC):
DEAD END CORRIDORS SHALL NOT EXCEED: 15M (50 FT)
COMMON PATH OF TRAVEL SHALL NOT EXCEED: 30M (100 FT)
MAX. TRAVEL DISTANCE TO AN EXIT: 91M (300 FT)
SATCOM FACILITY
UTILIZZO: UTILIZZO MISTO, USO NON SEPARATO
MAGAZZINI/GESTIONALE
GESTIONALE: "B" (UFFICIO) RISCHIO MODERATO,
IBC SEZ. 311.2
MAGAZZINO - RISCHIO ORDINARIO,
NFPA 101, CH. 42
MAGAZZINI: S-1 (MAGAZZINO/MECCANICO) RISCHIO MODERATO,
IBC SEZ. 311.2
MAGAZZINO - RISCHIO ORDINARIO,
NFPA 101, CH. 42
SEPARAZIONE UTILIZZI RICHIESTA (TAV. IBC 508.4): NESSUNA
TIPO DI CONTRUZIONE:
TIPO II - B, TOTALMENTE PROTETTA DA IMPIANTO SPRINKLER, IBC TAV. 503 E SEZ. 602
(NON PREVISTO NEI LOCALI IMPIANTI ELETTRICI)
AREA CONSENTITA EDIFICIO (TAV. IBC 503):
AREA LORDA CONSENTITA: 2,137 MQ LORDI (23,000 GSF)
PIANO TERRA:
AREA LORDA DI PROGETTO: 1,208 MQ LORDI (13.006 GSF)
ESTERNO (MEZZA AREA): 2 MQ LORDI (21 PQ)
AREA LORDA TOTALE: 1,210 MQ LORDI (13,024 GSF)
CARICO OCCUPANTE U.S. PIANO TERRA:
OCCUPANTI RIUNIONE:
56.6 MQ / 1.4 MQ/PERSONA = 41 PERSONE
OCCUPANTI GESTIONALE:
852.2 MQ / 9.3 MQ/PERSONA = 92 PERSONE
OCCUPANTI MAGAZZINO/MECCANICO:
226.4 MQ / 46.5 MQ/PERSONA = 5 PERSONE
UNITA' DI USCITA PREVISTE AL PIANO TERRA CAPACITA'
MAGAZZINO ORIZZONTALE:
46 / 0.20" (0.38 cm) 230 PERSONE
GESTIONALE ORIZZONTALE:
114 / 0.20" (0.38 cm) 228 PERSONE
ALTEZZA EDIFICIO (TAV. IBC 503)
ALTEZZA CONSENTITA: 2 PIANI (16.8 m) ALTEZZA EFFETIVA: 1 PIANO (8.2 m)
RISCHIO ORDINARIO MAGAZZINI (NFPA 101):
I CORRIDOI CIECHI NON DOVRANNO SUPERARE: 30 m (100 PIEDI) DISTANZA COMUNE DI PERCOSO NON SUPERIORE A : 30 m (100 PIEDI) PERCOSO MASSIMO EFFETTIVO VERSO UN'USCITA: 122 m (400 PIEDI)
RISCHIO ORDINARIO GESTIONALE (NFPA 101):
I CORRIDOI CIECHI NON DOVRANNO SUPERARE: 15 m (50 PIEDI) DISTANZA COMUNE DI PERCOSO NON SUPERIORE A : 30 m (100 PIEDI) PERCOSO MASSIMO EFFETTIVO VERSO UN'USCITA: 91 m (300 PIEDI)
SATCOM FACILITY
RO
RT
F B U
NO
M.
TE
N A
16616 E N G
D
NI E E R
OL V
SEAL
S
A
SFORP
E H C
I A L
OI N
OR L
T
U
AS
S
AT
C O
M R
EL
AY
P
AD
S
AN
D F
AC
IL
IT
Y
1118648
N
AV
AL
A
IR
S
TA
TI
O N
II
SI
G O
N
EL
LA
, S
IC
IL
Y, IT
AL
Y
SATISFACTORY TO
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
AN
D
A
TL
AN
TI
C
LA
N T
C
AP
IT
AL
IM
PR
O
VE
M
EN
TS
N
O R
FO
LK
, V
IR
G
IN
IA
D
EP
A R
TM
E
N T
O F
TH
E
N
AV
Y N
AV
AL
F A
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O
M M
A N
D
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
NOTE / N62470-09-R-9034 NOTE:
INC.ROGERS, LOVELOCK FRITZ,&
LICENSE # AA C000564 # EB 0000629
esignrchitectureA ngineeringE nteriorI D
4750 New Broad Street Orlando, FL www.rlfae.com
1 : 1
LIF
E
SA
FE
TY
N
OT
ES
GC202
CA
BML MEC JL
NO
TE
P
IA
NO
D
I S
IC
UR
EZ
ZA
14024659
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
| GENERAL-LIFE SAFETY |
| GC100A - COMPOSITE GROUND FLOOR PLAN - LIFE SAFETY |
| GC201 - LIFE SAFETY ANALYSIS |
| GC202 - LIFE SAFETY NOTES |
2012-04-17T08:17:18-0400
2012-04-17T08:17:56-0400
2012-04-17T08:17:56-0400
2012-04-17T08:18:26-0400
2012-04-17T08:18:51-0400
2012-04-17T08:18:52-0400
| 2012-05-08T10:47:29-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
| 2012-05-08T10:47:41-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
| 2012-05-08T10:47:43-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
| 2012-05-08T10:48:26-0400 | |
| Robert J. Tabet, P.E. |
| 2012-05-08T10:48:37-0400 | |
| Robert J. Tabet, P.E. |
| 2012-05-08T10:48:39-0400 | |
| Robert J. Tabet, P.E. |
2012-05-10T14:22:28-0400
2012-05-10T14:22:48-0400
2012-05-10T14:22:49-0400
File details come from the government source that posted it. Updated .