About this file

Part 02 LS

View the file

Other files

File Type Posted
UAS_SATCOM_RELAY_PADS_AND_FACILITY_11005.docx DOCX document
AMENDMENT_0011_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_0010_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_009_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_008_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_007_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
1118648_SPC_03-09-2015.pdf PDF
1118648_DWG_03-09-2015.pdf PDF
AMENDMENT_006_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
1118648_Amendment_2_Continuation_Sheet_2015-03-06.doc DOC document
AMENDMENT_005_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_004_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
PPI_015__Response_Attachments.pdf PDF
AMENDMENT_003_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_002_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part10-FP.pdf PDF
N62470-09-R9034_Part03-CIV.pdf PDF
N62470-09-R9034_Part05-GEO.pdf PDF
11005R_SPECS_Final-EBS_04.13.12_Vol_1.pdf PDF
11005_SPECS_Final-EBS_04.13.12_Vol_2.pdf PDF
N62470-09-R9034_Part08-AR.pdf PDF
N62470-09-R9034_Part04-CIV_(CONT).pdf PDF
N62470-09-R9034_Part11-FP_(CONT).pdf PDF
N62470-09-R9034_Part09-IN.pdf PDF
N62470-09-R9034_Part06-LAND.pdf PDF
N62470-09-R9034_Part13-ME.pdf PDF
AMENDMENT_0001N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part14-EL.pdf PDF
N62470-09-R9034_Part07-ST.pdf PDF
N62470-09-R9034_Part12-PL.pdf PDF
N62470-09-R9034_Part01-GEN.pdf PDF
N62470-09-R9034_Part08-AR.pdf PDF
N62470-09-R9034_Part03-CIV-revised.pdf PDF
Contract_Risk_Assessment_and_QA_Responsibility_Spreadsheet-.pdf PDF
N62470-09-R9034_Part01-GEN.pdf PDF
N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part04-CIV.pdf PDF
N62470-09-R9034_Part14-EL 1 .pdf PDF
11005R_SPECS_Final-EBS_04.13.12_Vol_1.pdf PDF
11005_SPECS_Final-EBS_04.13.12_Vol_2.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A B C E FD

COMM EXT

SECURE ROOM

IT-2 OPS

OFFICE

CORR

BREAK

CONFERENCE

CORR

VEST

TLT F

107 TLT M

STORAGE / SHOP

HVAC

BOILER

IT-1 RACK ROOM

CORR

ELEC

STOR

CORR

JAN

FEC

FE

FE

FE

FE

FE

FE

FE FE

0A

0D

0B0C

68 (INCHES)

3 (IEM)

46 (INCHES)

1 (IEM)

FE

FEC

46 (INCHES)

1 (IEM)

FE

NOTES:

SHEET NOTES:

NOTE:

NOTE DEL FOGLIO:

LEGENDA PIANO DI SICUREZZA

LIFE SAFETY LEGEND

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

TRAMEZZO REI 60

TRAMEZZO REI 120

1 HOUR SMOKE BARRIER

TRAMEZZO REI 60

2 HOUR SMOKE BARRIER

TRAMEZZO REI 120

FIRE SPRINKLER

SPRINKLER ANTINCENDIO

EXIT LIGHT

LUCIE INDAZIONE USCITA

SMOKE DETECTOR

RIVELATORE DE FUMO

FIRE ALARM SPEAKER

ALTOPARLANTE ALLARME INCENDIO

STOBE LIGHT

LUCE DELLO STROBOSCOPIO

DUCT SMOKE DETECTOR

RIVELATORE DI FUMO DA CANALE

COMBINATION SPEAKER STROBE

COMBINAZIONE

ALTOPARLANTE/LAMPEGGIANTE

MANUAL PULL STATION

PULSANTE MANUALEP

HEAT DETECTOR

RIVELATORE DE CALORE

FIRE EXTINGUISHER TABLE

TAVOLA DEGLI ESTINTORI ANTINCENDIO

TYPE HAZARD QTY

TIPO PERICOLO QUANTITA'

SECCO

CHIMICO

CLASS A/B

RATING

PORTATA

ROOM No.

NUMERO

STANZA

ROOM NAME

NOME STANZA

55A/233B;C

55A/233B;C CLASSE A/B

STORAGE/SHOP

HVAC

COMM EXT

IT-1 RACK ROOM

IT-2 OPS

ELECTRICAL ROOM

CORRIDOR

CORRIDOR

BOILER1

DRY

CHEMICAL

RO

RT

F B U

NO

M.

TE

N A

16616 E N G

D

NI E E R

OL V

SEAL

S

A

SFORP

E H C

I A L

OI N

OR L

T

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-09-R-9034 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

As indicated

CO

MP

OS

IT

E

GR

OU

ND

F

LO

OR

P

LA

N

- L

IF

E

SA

FE

TY

GC100A

CA

BML MEC JL

PI

AN

TA

C

OM

PO

SI

TA

P

IA

NO

T

ER

RA

PI

AN

O

DI

S

IC

UR

EZ

ZA

14024657

1 : 100A1 COMPOSITE GROUND FLOOR PLAN - LIFE SAFETY

PIANTA COMPOSITA PIANO TERRA - PIANO DI SICUREZZA

N

TRUE

NORTH

1:100 GRAPHIC SCALE (MILLIMETERS)

50000 1000 3000 10000

KEY PLAN

A

SCALA GRAFICA (MILLIMETRI)

TRAVEL DISTANCE / DISTANZA D'ESODO

PATH OF EGRESS

VIA DI FUGA

DISTANCE

DISTANZA

(MM)

DISTANCE

DISTANZA

(FT DECIMALS)

0A 30,761 mm 100.92 0B 31,268 mm 102.59 0C 31,960 mm 104.85 0D 47,264 mm 155.07

A. REFER TO SHEET GC201 FOR CALCULATIONS AND GC202 FOR LIFE

SAFETY NOTES.

A. FARE RIFERIMENTO AL FOGLIO GC201 PER CALCOLI E GC202 PER NOTE

PIANO DI SICUREZZA.

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

WALLS

BUILDING MEMBER IBC/NFPA

DOORS/

WINDOWS

EXTERIOR WALLS

INTERIOR WALLS

LOAD BEARING

NON LOAD BEARING

LOAD BEARING

NON LOAD BEARING

SPECIAL ROOMS

ROOM PARTITIONS

WAYS OF EGRESS

ELECTRICAL WITH UPS

COMMUNICATIONS

JANITOR'S CLOSET

MECHANICAL

BOILER ROOM

RACK ROOM

OPS

SECURE ROOM

WALLS

STORAGE/SHOP

STRUCTURAL FRAME

FLOOR CONSTRUCTION

COLUMNS SUPPORTING ROOF

ROOF CONSTRUCTION

* HORIZONTAL STRUCTURE RATING WILL BE EQUIVALENT TO WALL RATING

DESIGNED PER MOST STRINGENT OF THE TWO CODES - NO CONFLICT

ANTICIPATED

0 HR

0 HR

0 HR

0 HR

0 HR

1 HR

0 HR

0 HR

0 HR

1 HR

45 MIN

1 HR

0 HR

1 HR

0 MIN

0 MIN

0 MIN

0 MIN

0 MIN

45 MIN

0 MIN

0 MIN

0 MIN

45 MIN

45 MIN

45 MIN

45 MIN

0 MIN

0 HR

0 HR

0 HR

WALLS

ITALIAN CODE

DOORS/

WINDOWS

0 0

0 0

0 0

0 0 0 0

60 45

120 120

WALLS

SOLUTION

DOORS/

WINDOWS

0 0

0 0

0 0

0 0 0 0

60 60

120 120

CONSTRUCTION

250MM CONCRETE WALL

200MM REINFORCED CONCRETE WALL W/ STUD & GWB

METAL STUD WALL W/ TWO LAYERS OF GWB

METAL STUD WALL W/ TWO LAYERS OF GWB

200MM REINFORCED CONCRETE & 200MM REINFORCED CONCRETE W/ STUD & GWB

200MM REINFORCED CONCRETE

METAL STUD WALL W/ TWO LAYERS OF GWB

200MM REINFORCED CONCRETE & 200MM REINFORCED CONCRETE W/ STUD & GWB

METAL STUD WALL W/ FOUR LAYERS OF GWB

200MM REINFORCED CONCRETE

200MM REINFORCED CONCRETE W/ STUD & GWB

200MM REINFORCED CONCRETE W/ STUD & GWB

200MM REINFORCED CONCRETE & 200MM REINFORCED CONCRETE W/ STUD & GWB

STEEL JOISTS/FABRICATED ROOF PANEL ASSEMBLY

CONCRETE W/ TILE-RUBBER-CARPET FLOORING

MURI

ELEMENTO DELL'EDIFICIO IBC/NFPA

PORTE/

FINESTRE

MURI ESTERNI

MURI INTERNI

PORTANTI

NON PORTANTI

PORTANTI

NON PORTANTI

LOCALI SPECIALI

TRAMEZZI STANZE

VIE DI USCITA

ELETTRICO CON UPS

COMUNICAZIONE

LOCALE DI SERVIZIO

MECCANICA

CENTRALE TERMICA

RACK ROOM

OPS

SECURE ROOM

MURI

STORAGE/SHOP

OSSATURA STRUTTURALE

COSTRUZIONE PAVIMENTO

PILASTRI A SUPPORTO COPERTURA

COSTRUZIONE DELLA COPERTURA

* LA CLASSE DI RESISTENZA DELLA STRUTTURA ORIZZONTALE SARA'

EQUIVALENTE ALLA CLASSE DI RESISTENZA DEL MURO

PROGETTATI PER LE PRESCRIZIONI PIU' RESTRITTIVE DEI DUE CODICI - NON SI

PREVEDE CONFLITTO

0 ORE

0 ORE

0 ORE

0 ORE

0 ORE

1 ORE

0 ORE

0 ORE

0 ORE

1 ORA

45 MIN

1 ORA

0 ORE

1 ORA

0 MIN

0 MIN

0 MIN

0 MIN

0 MIN

45 MIN

0 MIN

0 MIN

0 MIN

45 MIN

45 MIN

45 MIN

45 MIN

0 MIN

0 ORE

0 ORE

0 ORE

MURI

CODICE ITALIANO

PORTE/

FINESTRE

0 0

0 0

0 0

0 0 0 0

60 45

120 120

MURI

SOLUZIONE PROPOSTA

PORTE/

FINESTRE

0 0

0 0

0 0

0 0 0 0

60 45

120 120

COSTRUZIONE

MURO IN CLS ARMATO 250MM

MURO IN CLS ARMATO 200MM

PARETE IN MONTANTI METALLICI CON 2 STRATI DI GWB

PARETE IN MONTANTI METALLICI CON 2 STRATI DI GWB

MURO IN CLS ARMATO 200MM E MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB

MURO IN CLS ARMATO 200MM

PARETE IN MONTANTI METALLICI CON 2 STRATI DI GWB

MURO IN CLS ARMATO 200MM E MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB

PARETE IN MONTANTI METALLICI CON 4 STRATI DI GWB

MURO IN CLS ARMATO 200MM

MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB

MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB

MURO IN CLS ARMATO 200MM E MURO IN CLS ARMATO 200MM CON MONTANTI METALLICI E GWB

TRAVETTI DI ACCIAIO/PANNELLI DI COPERTURA PREFORMATI

CLS CON PAVIMENTAZIONE IN PIASTRELLE-GOMMA-MOQUETTE

0 0

0 0 0 0

RO

RT

F B U

NO

M.

TE

N A

16616 E N G

D

NI E E R

OL V

SEAL

S

A

SFORP

E H C

I A L

OI N

OR L

T

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-09-R-9034 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 1

LIF

E

SA

FE

TY

A

NA

LY

SI

S

GC201

CA

BML MEC JL

AN

AL

IS

I P

IA

NO

D I S

IC

UR

EZ

ZA

14024658

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

FACILITY IS TO BE SPRINKLERED THROUGHOUT

(SPRINKLERS NOT PROVIDED IN ELECTRICAL AND COOMUNCATION ROOMS PER

ITALIAN NORM).

DUE TO ANALYSIS AND INCORPORATION OF THE MOST STRINGENT ASPECTS OF

BOTH CODES, WE ANTICIPATE NO CONFLICTS.

PRIMARY OCCUPANTS ON BASE:

MILITARY

U.S. CODES REFERENCED:

NFPA 101 LIFE SAFETY CODE (2009)

INTERNATIONAL BUILDING CODE (2009)

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (2009)

U.S. OCCUPANT LOAD CALCULATIONS:

100 SF (9.3 SM) / PERSON PER BUSINESS OCCUPANCY

500 SF (46.4 SM) / PERSON PER STORAGE OCCUPANCY

(1) ITALIAN EGRESS MODULE = 60 CM (MIN 120 CM PER EXIT)

ITALIAN LAWS AND DECREES:

D.P.R. 503, 24TH JULY 1996

D.M. 236, 24TH JUNE 1989

D.M. 25TH AUGUST 1989

D.M. 19TH AUGUST 1996

D.M. 18TH MARCH 1998

CIRCOLARE 16, 15TH FEBRUARY 1951 OF THE MINISTRY OF INTERIOR

D.M. 30TH NOVEMBER 1983

ITALIAN CROWDING INDEXES:

Ns = 0.10 FOR OFFICES, STORAGE, AND SIMILAR Ns = 0.40 FOR COMMON AREAS Ns = 0.70 FOR CONCENTRATED USE AREAS

(1) ITALIAN EGRESS MODULE = 60 CM (MIN 120 CM PER EXIT)

ITALIAN OUTFLOW CAPACITY PER ITALIAN EGRESS MODULE (IEM):

50 PERSONS, GROUND FLOOR

37.5 PERSONS, FIRST FLOOR

NOTES:

L'EDIFICIO SARA' TOTALMENTE PROTETTO DA UN IMPIANTO SPRINKLER

(SPRINKLER NON PREVISTO NEI LOCALI ELETTRICI E COMUNICAZIONI IN BASE ALLE

NORME ITALIANE)

DATA L'ANALISI E L'INCORPORAZIONE DEI PIU' RIGOROSI ASPETTI DI ENTRAMBI I

CODICI, SI PREVEDE L'ASSENZA DI CONFLITTUALITA'

OCCUPANTI PRINCIPALI DELLA BASE:

MILITARI

CODICI DI RIFERMENTO U.S.:

NFPA 101 LIFE SAFETY CODE (2009)

INTERNATIONAL BUILDING CODE (2009)

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (2009)

INDICI STANDARD DI SUPERFICIE U.S.:

100 SF (9.3 MQ) / PERSONA CON ATTIVITA’ GESTIONALE

500 SF (46.4 MQ) / PERSONA ADDETTA AL MAGAZZINO

LEGGI E DECRETI ITALIANI:

D.P.R. 503, 24 LUGLIO1996

D.M. 236, 24 GIUGNO 1989

D.M. 25 AGOSTO 1989

D.M. 19 AGOSTO 1996

D.M. 18 MARZO 1998

CIRCOLARE 16, 15 FEBBRAIO 1951 DEL MINISTERO DEGLI INTERNI

D.M. 30 NOVEMBRE 1983

INDICI ITALIANI DI AFFOLLAMENTO:

Ns = 0.10 PER UFFICI, MAGAZZINI E SIMILI Ns = 0.40 PER AREE COMUNI Ns = 0.70 PER AREE DI USO CONCENTRATO

(1) MODULO DI USCITA ITALIANO = 60 cm (MIN 120 cm PER USCITA)

CAPACITA' DI DEFLUSSO SECONDO IL MODULO ITALIANO PER LE VIE DI USCITA (IEM):

50 PERSONE, PIANO TERRA

37.5 PERSONE, PRIMO PIANO

NOTE:

OCCUPANCY: MIXED OCCUPANCY, NON-SEPARATED USE

STORAGE/BUSINESS

BUSINESS: "B" (OFFICE) MODERATE-HAZARD,

IBC SEC 311.2

STORAGE - ORDINARY HAZARD,

NFPA 101, CH. 42

STORAGE: S-1 (STORAGE/MECHANICAL) MODERATE-HAZARD,

IBC SEC 311.2

STORAGE - ORDINARY HAZARD,

NFPA 101, CH. 42

REQUIRED SEPARATION OF OCCUPANTS (IBC TABLE 508.4): NONE

CONSTRUCTION TYPE:

TYPE II - B, FULLY SPRINKLERED, IBC TABLE 503 AND SEC 602

(NOT PROVIDED IN ELECTRICAL EQUIPMENT ROOMS)

ALLOWABLE BUILDING AREA (IBC TABLE 503):

ALLOWABLE GROSS AREA: 2,137 GSM (23,000 GSF)

GROUND FLOOR:

DESIGN GROSS AREA: 1,208 GSM (13,006 GSF)

EXTERIOR (HALF AREA): 2 GSM (21 GSF)

TOTAL GROSS AREA: 1,210 GSM (13,024 GSF)

GROUND FLOOR U.S. OCCUPANT LOAD:

ASSEMBLY:

56.6 SM / 1.4 SM/PER = 41 PEOPLE

BUSINESS:

852.2 SM / 9.3 SM/PER = 92 PEOPLE

STORAGE/MECHANICAL:

226.4 SM / 27.9 SM/PER = 9 PEOPLE

GROUND FLOOR PROVIDED EXIT UNITS CAPACITY

STORAGE HORIZONTAL:

46 @ 0.20" (0.38 CM): 230 PEOPLE

BUSINESS HORIZONTAL:

114 @ 0.20" (0.38 CM): 228 PEOPLE

BUILDING HEIGHT (IBC TABLE 503)

ALLOWABLE HEIGHT: 2 STORIES (16.8 M)

ACTUAL HEIGHT: 1 STORY (8.2 M)

STORAGE, ORDINARY HAZARD (IBC):

DEAD END CORRIDORS SHALL NOT EXCEED: 30M (100 FT)

COMMON PATH OF TRAVEL SHALL NOT EXCEED: 30M (100 FT)

MAX. TRAVEL DISTANCE TO AN EXIT: 122M (400 FT)

BUSINESS, ORDINARY HAZARD (IBC):

DEAD END CORRIDORS SHALL NOT EXCEED: 15M (50 FT)

COMMON PATH OF TRAVEL SHALL NOT EXCEED: 30M (100 FT)

MAX. TRAVEL DISTANCE TO AN EXIT: 91M (300 FT)

SATCOM FACILITY

UTILIZZO: UTILIZZO MISTO, USO NON SEPARATO

MAGAZZINI/GESTIONALE

GESTIONALE: "B" (UFFICIO) RISCHIO MODERATO,

IBC SEZ. 311.2

MAGAZZINO - RISCHIO ORDINARIO,

NFPA 101, CH. 42

MAGAZZINI: S-1 (MAGAZZINO/MECCANICO) RISCHIO MODERATO,

IBC SEZ. 311.2

MAGAZZINO - RISCHIO ORDINARIO,

NFPA 101, CH. 42

SEPARAZIONE UTILIZZI RICHIESTA (TAV. IBC 508.4): NESSUNA

TIPO DI CONTRUZIONE:

TIPO II - B, TOTALMENTE PROTETTA DA IMPIANTO SPRINKLER, IBC TAV. 503 E SEZ. 602

(NON PREVISTO NEI LOCALI IMPIANTI ELETTRICI)

AREA CONSENTITA EDIFICIO (TAV. IBC 503):

AREA LORDA CONSENTITA: 2,137 MQ LORDI (23,000 GSF)

PIANO TERRA:

AREA LORDA DI PROGETTO: 1,208 MQ LORDI (13.006 GSF)

ESTERNO (MEZZA AREA): 2 MQ LORDI (21 PQ)

AREA LORDA TOTALE: 1,210 MQ LORDI (13,024 GSF)

CARICO OCCUPANTE U.S. PIANO TERRA:

OCCUPANTI RIUNIONE:

56.6 MQ / 1.4 MQ/PERSONA = 41 PERSONE

OCCUPANTI GESTIONALE:

852.2 MQ / 9.3 MQ/PERSONA = 92 PERSONE

OCCUPANTI MAGAZZINO/MECCANICO:

226.4 MQ / 46.5 MQ/PERSONA = 5 PERSONE

UNITA' DI USCITA PREVISTE AL PIANO TERRA CAPACITA'

MAGAZZINO ORIZZONTALE:

46 / 0.20" (0.38 cm) 230 PERSONE

GESTIONALE ORIZZONTALE:

114 / 0.20" (0.38 cm) 228 PERSONE

ALTEZZA EDIFICIO (TAV. IBC 503)

ALTEZZA CONSENTITA: 2 PIANI (16.8 m) ALTEZZA EFFETIVA: 1 PIANO (8.2 m)

RISCHIO ORDINARIO MAGAZZINI (NFPA 101):

I CORRIDOI CIECHI NON DOVRANNO SUPERARE: 30 m (100 PIEDI) DISTANZA COMUNE DI PERCOSO NON SUPERIORE A : 30 m (100 PIEDI) PERCOSO MASSIMO EFFETTIVO VERSO UN'USCITA: 122 m (400 PIEDI)

RISCHIO ORDINARIO GESTIONALE (NFPA 101):

I CORRIDOI CIECHI NON DOVRANNO SUPERARE: 15 m (50 PIEDI) DISTANZA COMUNE DI PERCOSO NON SUPERIORE A : 30 m (100 PIEDI) PERCOSO MASSIMO EFFETTIVO VERSO UN'USCITA: 91 m (300 PIEDI)

SATCOM FACILITY

RO

RT

F B U

NO

M.

TE

N A

16616 E N G

D

NI E E R

OL V

SEAL

S

A

SFORP

E H C

I A L

OI N

OR L

T

U

AS

S

AT

C O

M R

EL

AY

P

AD

S

AN

D F

AC

IL

IT

Y

1118648

N

AV

AL

A

IR

S

TA

TI

O N

II

SI

G O

N

EL

LA

, S

IC

IL

Y, IT

AL

Y

SATISFACTORY TO

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

A

TL

AN

TI

C

LA

N T

C

AP

IT

AL

IM

PR

O

VE

M

EN

TS

N

O R

FO

LK

, V

IR

G

IN

IA

D

EP

A R

TM

E

N T

O F

TH

E

N

AV

Y N

AV

AL

F A

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

A N

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

NOTE / N62470-09-R-9034 NOTE:

INC.ROGERS, LOVELOCK FRITZ,&

LICENSE # AA C000564 # EB 0000629

esignrchitectureA ngineeringE nteriorI D

4750 New Broad Street Orlando, FL www.rlfae.com

1 : 1

LIF

E

SA

FE

TY

N

OT

ES

GC202

CA

BML MEC JL

NO

TE

P

IA

NO

D

I S

IC

UR

EZ

ZA

14024659

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

GENERAL-LIFE SAFETY
GC100A - COMPOSITE GROUND FLOOR PLAN - LIFE SAFETY
GC201 - LIFE SAFETY ANALYSIS
GC202 - LIFE SAFETY NOTES

2012-04-17T08:17:18-0400

2012-04-17T08:17:56-0400

2012-04-17T08:17:56-0400

2012-04-17T08:18:26-0400

2012-04-17T08:18:51-0400

2012-04-17T08:18:52-0400

2012-05-08T10:47:29-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.
2012-05-08T10:47:41-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.
2012-05-08T10:47:43-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.
2012-05-08T10:48:26-0400
Robert J. Tabet, P.E.
2012-05-08T10:48:37-0400
Robert J. Tabet, P.E.
2012-05-08T10:48:39-0400
Robert J. Tabet, P.E.

2012-05-10T14:22:28-0400

2012-05-10T14:22:48-0400

2012-05-10T14:22:49-0400

File details come from the government source that posted it. Updated .