N62470-09-R9034_Part10-FP.pdf
PDF 1 MB Posted
- Solicitation number
- N33191-15-R-0802
About this file
Part 10 FP
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FI
RE
P
RO
TE
CT
IO
N
SI
TE
P
LA
N
FX001
1118648
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
N62470-09-R-9034 NOTA:NOTE /
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
As Indicated
14024777
RO
RT
F
BU
NO
M.
TE
NA
16616
ENG
D
NI EER
OL V
SEAL
S
A
SFORP
E H C
I
AL
OI N
OR L
T
KB
KB
IDRANTE
ANTINCENDIO
SCALE: 1:500
SITE LAYOUT PLAN1
LEGEND
FIRE HYDRANT
UNDERGROUND WATER MAIN
POST INDICATOR VALVE
THRUST BLOCK
FENCE
FINISHED FLOOR ELEVATION
2-1/2" SIAMESE FIRE DEPARTMENT CONNECTION
KB KEY BOX
IDRANTE ANTINCENDIO
PLANIMETRIA DEL SITO
CONDOTTA INTERRATA DI
COLONNINA INDICATRICE
BLOCCO REGGISPINTA
RECINZIONE
QUOTA PAVIMENTO FINITO
ATTACCO SIAMESE DA 2-1/2" PER COLLEGAMENTO VV.F.
ARMADIETTO PORTACHIAVI
LEGENDA
/ SCALA: 1:500
ADDUZIONE ACQUA
DI VALVOLA
1:500 GRAPHIC SCALE (METERS)
200 10
N
P
RO
TE
CT
IO
N
FL
OO
R
PL
AN
FX101
1118648
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
N62470-09-R-9034 NOTA:NOTE /
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
As Indicated
14024778
RO
RT
F
BU
NO
M.
TE
NA
16616
ENG
D
NI EER
OL V
SEAL
S
A
SFORP
E H C
I
AL
OI N
OR L
T
2-1/2" SIAMESE FIRE DEPARTMENT CONNECTION
UNDERGROUND FIRE WATER MAINS
POST INDICATOR VALVE
LEGEND
SPRINKLER RISER ASSEMBLY
SCALE: 1:100
FIRE PROTECTION FLOOR PLAN
FDC #1
ORDINARY HAZARD GROUP 1
LIGHT HAZARD
NON-SPRINKLERED AREA
SEE CIVIL FOR UG
ROUTING &
LOCATION OF PIV
ORDINARY HAZARD GROUP 2
FDC #2
GENERAL NOTES:
1. FINAL SPRINKLER PLACEMENT, PIPE ROUTING, AND QUANTITY SHALL BE COORDINATED
BETWEEN SPRINKLER CONTRACTOR AND GENERAL CONTRACTOR. DESIGN SHALL PROVIDE
MINIMUM ACCEPTABLE COVERAGE, FLOW, AND PRESSURE AS SPECIFIED UNDER NFPA 13
AND PER CONTRACT.
2. FIRE CONTRACTOR IS RESPONSIBLE FOR LOCATION OF TEST CONNECTION MEETING
LOCALLY ENFORCED CODE.
3. ALL VALVES SHALL BE READILY ACCESSIBLE FOR OPERATION.
4. ANY PORTION OF THIS SPRINKLER SYSTEM WHICH IS EXPOSED TO FREEZING SHALL BE
ADEQUATELY PROTECTED AGAINST THIS EXPOSURE. HEAT TAPE IS NOT ACCEPTABLE.
5. SPRINKLER RISER FEED FROM HAZMIN FIRE PUMPS RATED AT 4,731 LPM (1250 GPM) AT 5.17
BAR (75 PSI) SEE CU104 FOR CONNECTION AND LOCATION.
6. SPRINKLER SYSTEM TO BE INSTALLED PER NFPA 13 AND PER CONTRACT.
7. PROVIDE WET PIPE SPRINKLERS WITH A LIGHT HAZARD DENSITY OF 4.1 L/MIN/SQ. M FOR
280 SQ. METERS (0.10 GPM OVER 3,000 SQ. FT.). INCLUDES REDUCTION FOR QUICK
RESPONSE SPRINKLER AND LOW CEILINGS.
8. PROVIDE WET PIPE SPRINKLERS WITH ORDINARY GROUP 1 HAZARD DENSITY OF 6.1
L/MIN/SQ. M 280 SQ. METERS (0.15 GPM OVER 3,000 SQ. FT.) FOR RACK, HVAC AND TELECOM
ROOMS. INCLUDES INCREASE FOR SLOPED ROOF/CEILING.
9. PROVIDE WET PIPE SPRINKLERS WITH ORDINARY GROUP 2 HAZARD DENSITY OF 8.1
L/MIN/SQ. M 280 SQ. METERS (0.20 GPM OVER 3,000 SQ. FT.) FOR THE BOILER ROOM.
10. PIPE IN WET PIPE SYSTEM TO BE SCHEDULE 40 BLACK STEEL FOR THREADED PIPES
SMALLER THAN 50mm (2 INCHES) AND SCHEDULE 10 FOR GROOVED PIPE 50mm (2 INCHES)
OR LARGER.
11. PENDANT SPRINKLERS IN FINISHED ROOMS SHALL BE CONCEALED 155° F, K=5.6, QUICK
RESPONSE WITH A WHITE FINISH.
12. SPRINKLER SHALL BE CENTERED IN THE CEILING TILE, WITH A MINIMUM OF 150mm (6 INCH)
TO THE GRID.
13. UPRIGHT SPRINKLER SHALL BE 155° F, K=5.6 QUICK RESPONSE, BRONZE FINISH WITH WIRE
GUARDS.
14. GENERAL CONTRACTOR SEE SITE UTILITY PLAN SHEET CU104 FOR THE FIRE PUMP HOUSE
LOCATION.
LEGENDA
STRUTTURA MONTANTE SPRINKLER
TUBO INTERRATO ADDUZIONE ACQUA ANTINCENDIO
NOTE GENERALI:
1 . LA DISPOSIZIONE QUANTITA' E PERCORSO TUBAZIONI DEGLI SPRINKLER SARA'
COORDINATA FRA L'APPALTATORE DEGLI SPRINKLER E L'APPALTATORE
PRINCIPALE. IL PROGETTO DOVRA' PREVEDERE COPERTURA, FLUSSO E
PRESSIONE ACCETTABILI COME SPECIFICATO IN NFPA 13 E NEL CONTRATTO.
2. L'APPALTATORE DELL'ANTINCENDIO E' RESPONSABILE DELL'UBICAZIONE
DELL'ATTACCO DI PROVA IN ACCORDO CON LA NORMA APPLICABILE.
3. TUTTE LE VALVOLE SARANNO FACILMENTE ACCESSIBILI PER L'USO.
4. LE PARTI DI QUESTO IMPIANTO SPRINKLER CHE SIANO ESPOSTE AL GELO
SARANNO PROTETTE ADEGUAMENTE CONTRO TALE ESPOSIZIONE. IL NASTRO
SCALDANTE NON E' ACCETTABILE.
5. LA MONTANTE DEGLI SPRINKLER E' ALIMENTATA DA POMPE ANTINCENDIO DA
4.731 LPM (1250 GPM), 5.17 BAR (75 PSI). PER ATTACCO E UBICAZIONE VEDERE
CU104.
6. L'IMPIANTO SPRINKLER DEVE ESSERE INSTALLATO IN BASE A NFPA 13 E COME
DA CONTRATTO.
7. PROVVEDERE SPRINKLER A TUBO UMIDO CON UNA DENSITA' DI PERICOLO
LEGGERO DI 4.1 L/MIN/M2 PER 280M2 (0.15 GPM SU 3000 M2). INCLUDERE
RIDUZIONE PER RISPOSTA PRONTA SPRINKLER E SOFFITTI BASSI.
8. PROVVEDERE SPRINKLER A TUBO UMIDO CON UNA DENSITA' DI PERICOLO
GRUPPO 1 ORDINARIO DI 6.1 L/MIN/M2 PER 280M2 (0.15 GPM SU 3000 M2) PER
LOCALI RACK, HVAC E TELECOM. INCLUDERE MAGGIORAZIONE PER
TETTO/SOFFITTO INCLINATO.
9. PROVVEDERE SPRINKLER A TUBO UMIDO CON DENSITA' DI PERICOLO GRUPPO
2 ORDINARIO DI 8.1 L/MIN/M2.
10. I TUBI NEI SISTEMI A TUBO UMIDO DEVONO ESSERE IN ACCIAIO NERO SCH. 40
PER TUBI FILETTATI MINORI DI 50mm (2") O MAGGIORI.
11. GLI SPRINKLER A SOSPENSIONE NEI LOCALI FINITI DOVRANNO ESSERE DEL
TIPO NASCOSTO, 155° F, K=5.6, A RISPOSTA RAPIDA VERNICIATI BIANCHI.
12. GLI SPRINKLER DOVRANNO ESSERE INSTALLATI AL CENTRO DEI QUADROTTI
DEL SOFFITTO, CON UN MINIMO DI 150mm (6") DALLA GRIGLIA.
13. GLI SPRINKLER UPRIGHT DOVRANNO ESSERE PER 155° F, K=5.6, A RISPOSTA
RAPIDA. COLORE BRONZO CON RETE DI PROTEZIONE.
14. PER L'UBICAZIONE DELLE POMPE ANTINCENDIO L'APPALTATORE GENERALE
DEVE VEDERE LA PLANIMETRIA SERVIZI DEL SITO AL FOGLIO CU104.
PIANTA PROTEZIONE INCENDIO
ATTACCO SIAMESE DA 2-1/2" PER COLLEGAMENTO VV.F.
COLONNINA INDICATRICE DI VALVOLA
PERICOLO ORDINARIO GRUPPO 1
PERICOLO ORDINARIO GRUPPO 2
PERICOLO LEGGERO
AREA NON PROTETTA D ASPRINKLER
VEDERE DISEGNI CIVILI
PER PERCORSI INTERRATI
E UBICAZIONE PIV
/ SCALA: 1:100
KEY PLAN
1:100 GRAPHIC SCALE (MILLIMETERS)
50000 1000 2500 10000
A
N
SPRINKERED DI EDIFICIO
BUILDING SPRINKLERED
P
RO
TE
CT
IO
N
DE
TA
ILS
FX102
1118648
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
N62470-09-R-9034 NOTA:NOTE /
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
As Indicated
14024779
RO
RT
F
BU
NO
M.
TE
NA
16616
ENG
D
NI EER
OL V
SEAL
S
A
SFORP
E H C
I
AL
OI N
OR L
T
FDC
RISER CHECK VALVE
OS&Y VALVE W/
TAMPER SWITCH
TO SYSTEM
400mm X 600mm
MIN. SPLASH
BLOCK
50mm DRAIN AT
EXTERIOR
EXTERIOR
400mm X 600mm
PARASPRUZZI
F
45° GALV. ELBOW
CONCRETE SPLASH BLOCK
20mm DRAIN PIPE TO REMOTE
POINT ON SPRINKLER SYSTEM
SLOPE TO EXTERIOR OUTLET
ESCHUTEON
20mm BRONZE GLOBE VALVE
SECURE PIPE TIGHT TO WALL
SURFACE
GRADE/
CEILING/
PARASPRUZZI IN CLS
VALVOLA A GLOBO DA 20mm
IN BRONZO
TERRENO
ESCHUTEON
BORCHIA
CONTROSOFFITTO
13mm ORIFICE BRASS FITTING
CONCRETE SPLASH BLOCK
TO BRANCH LINE
ESCHUTEON
25mm UNION
25mm BRONZE GLOBE VALVE
SECURE PIPE TIGHT TO WALL
SURFACE
GRADE/
PACK WITH MINERAL WOOL &
CAULK WATERTIGHT
GIUNTO A 3 PEZZI
TERRENO
ESCHUTEON
AFFIX PERMANENT SIGN TO WALL
ADJACENT TO VALVE TO READ
SPRINKLER FLOW
TEST VALVE
SLOPE
PENDENZA
FLANGE CONNECTION
COLLEGAMENTO A FLANGIA
6mm X 32mm PIPE CLAMP MORSETTO TUBO 6mm X 32mm
BITUMASTIC PACKING -
MODULAR RUBBER SEAL
(OPTIONAL)
GUARNIZIONE BITUMINOSA-
SIGILLATURA MODULARE IN
GOMMA (OPZIONALE)
DUCTILE IRON
FEEDER PIPE
2 (16mm) COATED STEEL RETAINING ROD WITH (20mm) TIE BOLTS
6mm X 32mm IRON PIPE STRAP
FASCETTA TUBO IN FERRO
6mm X 32mm
EXTERIOR WALL
PARETE ESTERNA
WATER STOP
ALLOY BOLT (TYP.)
BULLONE IN LEGA (TIPICO)
FOLLOWER GLAND
PREMISTOPPA SUSSEGUENTE
RUBBER GASKET
GUARNIZIONE IN GOMMA
SLEEVE
MANICOTTO
FIXED RETAINER GLAND
PREMISTOPPA FISSO DI
FERMO
WATER SUPPLY
SLEEVE
MANICOTTO
CONCRETE SILL
NO OPENING CLEARANCE REQUIRED WITH SEISMIC FLEXIBLE COUPLINGS WITHIN 300mm
OF EACH SIDE OF MASONRY WALL, NOT REQUIRED FOR FRANGIBLE CONSTRUCTION
(GYPSUM BOARD)
FIRE RATED PUTTY IN ANNULAR SPACE OF
RATED WALLS, MIN THICKNESS/UL SYSTEM
MIN. 150mm THICK MASONRY WALL
STEEL PIPE MIN. SCHEDULE 10 MAX.
DIAMETER 600mm
TYPICAL 1 & 2 HR. RATED WALL PENETRATION, UL SYSTEM No WJ-1065 ATTRAVERSAMENTO TIPICO PARETE REI 60' E 120', OMOLOGAZIONE UL No WJ-1065
SEISMIC FLEXIBLE COUPLING
SEISMIC FLEXIBLE COUPLING
50mm CLEARANCE FOR PIPES OVER 90mm 25mm CLEARANCE FOR PIPES UP TO 90mm
FOAM BACKER ROD
VALVOLA OS&Y
CON DISPOSITIVO
ANTIMANOMISSIONE
ALL'IMPIANTO
VALVOLA DI RITEGNO
SCARICO DA 50mm
ALL'ESTERNO
ESTERNO
TUBO DI DRENAGGIO DA 20mm
DAL PUNTO PIU' LONTANO
DELL'IMPIANTO SPRINKLER IN
PENDENZA FINO AL PUNTO DI
USCITA ALL'ESTERNO
BORCHIA
FISSARE SALDAMENTE IL TUBO
ALLA SUPERFICIE DELLA
PARETE
GOMITO ZINCATO A 45° CON
LEVIGATURA
CEILING/ CONTROSOFFITTO
BORCHIA
BORCHIA
APPORRE UN SEGNO PERMANENTE
SULLA PARETE ADIACENTE ALLA
VALVOLA DA SEGNALARE
VALVOLA DI PROVA
OPERAZIONE SPRINKLER
FISSARE SALDAMENTE IL TUBO
ALLA SUPERFICIE DELLA
PARETE
PARASPRUZZI IN CLS
45° GALV. ELBOW W/ SMOOTH
GOMITO ZINCATO A 45° CON
LEVIGATURA
DIAFRAMMA CALIBRATO IN
OTTONE
VALVOLA A GLOBO DA 1" IN
BRONZO
RIEMPIRE CON LANA MINERALE E
SIGILLARE A TENUTA STAGNA
GIUNTO A TENUTA
STAGNA
TUBO IN GHISA
MALLEABILE
SOGLIA IN CLS
2 TIRANTI ANTIPERCUSSIONE DA
16mm IN ACCIAIO VERNICIATO CON
BULLONI DI SERRAGGIO M18
ADDUZIONE
ACQUA
MASTICE ANTINCENDIO NELLO SPAZIO
ANULARE DELLA PARETE REI, SPESSORE
MINIMO COME OMOLOGATO UL
GIUNTO FLESSIBILE
ANTISISMICO
LUCE NETTA 25mm PER TUBI FINO A 90mm LUCE NETTA 50mm PER TUBI > DI 90mm
GIUNTO FLESSIBILE
ANTISISMICO
PARETE IN MURATURA
SPESS. MIN. 150mm
TUBO IN ACCIAIO SCH. 10 MIN.
DIAMETRO MAX 600mm
GIUNTO FLESSIBILE
ANTISISMICO
NESSUNA APERTURA NETTA CON GIUNTI FLESSIBILI E' RICHIESTA ENTRO 300mm DI CIASCUN
LATO DELLA PARETE IN MURATURA. NESSUNA RICHIESTA PER COSTRUZIONI FRAGILI
(LASTRE DI CARTONGESSO)
OAKUM PACKING (OMIT IF
RUBBER SEAL IS USED)
GUARNIZIONE IN CANAPA
(DA OMETTERE SE E' USATA
LA SIGILLATURA IN GOMMA)
NTS
RISER DIAGRAM
FLOOR
150mm (6")
50mm DRAIN TO EXTERIOR
6" UNDERGROUND SUPPLY WITH
RETAINING RODS
PRESSURE GAUGE
RISER CHECK VALVE
FLOW SWITCH
NTS
RISER ROOM LAYOUT
OS&Y VALVE W/ TAMPER SWITCH
GRADE
SCHEMA
MANOMETRO
CONCRETE
SPLASH BLOCK
PARASPRUZZI
IN CLS
FDC
CHECK VALVE W/
BALL DRIP TO
EXTERIOR
VALVOLA DI
RITEGNO A SFERA
ANTIGOCCIA
ALL'INTERNO
TO WET SYSTEM
WIRE TO FIRE
ALARM PANEL
/ PAVIMENTO
/ NON IN SCALA / NON IN SCALA
TERRENO
CAVO DI
COLLEGAMENTO AL
QUADRO ALLARME
ANTINCENDIO
ALL'IMPIANTO AD
UMIDO
FLUSSOSTATO
VALVOLA DI RITEGNO
SCARICO DA 50mm
ALL'ESTERNO
VALVOLA OS&Y CON DISPOSITIVO
ANTIMANOMISSIONE
TUBO DI ADDUZIONE DA 150mm CON
TIRANTI ANTIPERCUSSIONE
SCHEMA LOCALE
1 2
NTS
TYPICAL LOW POINT DRAIN
NTS
TYPICAL WET PIPE TEST DRAIN
/ NON IN SCALA
/ NON IN SCALA
PUNTO BASSO DRENAGGIO DRENAGGIO DI PROVA
4 5
NTS
TYPICAL WALL PENETRATION DETAIL
/ NON IN SCALA
PARETE
PARTICOLARE ATTRAVERSAMENTO
NTS
RISER DETAIL
/ NON IN SCALA
ADDUZIONE
PARTICOLARE SCHEMA
FX103
R
E
PR
O
TE
C
TI
O N
D
ET
AI
L
1118648
1 2
PM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
A
B
C
D
1 2 3 4 5
3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
OF
EPROJECT NO.:
DRAWFORM REVISION: 10 MARCH 2009
N62470-09-R-9034 NOTA:NOTE /
IF THIS DRAWING IS LESS THAN 841 X 594mm
IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm
E' UN DISEGNO A DIMENSIONI RIDOTTE
As Indicated
14024780
RO
RT
F
BU
NO
M.
TE
NA
16616
ENG
D
NI EER
OL V
SEAL
S
A
SFORP
E H C
I
AL
OI N
OR L
T
NTS
SECTION
GROUND FLR
T.O CONC
ROOF
LOWER FLR
WHITE CONCEALED
SPRINKLER3660mm (144")
SEZIONE
13 2
COPERTURA
ESTRADOSSO CLS
PIANO TERRA
SOTTOPAVIMENTO
/ NON IN SCALA
SPRINKLER BIANCO
NASCOSTO
WHITE CONCEALED
SPRINKLER
3250mm (128") SPRINKLER BIANCO
NASCOSTO
NTS
F.D CONNECTION
/ NON IN SCALA
COLLEGAMENTO VV.F.
NTS
SECTION
BRONZE UPRIGHT
SPRINKLERS W/
GUARDS OVER
STORAGE/SHOP
BRONZE UPRIGHT SPRINKLERS W/
GUARDS OVER HVAC/BOILER
T.O CONC
ROOF
SEZIONE
13 2
/ NON IN SCALA
SPRINKLER UPRIGHT BRONZEO CON
RETE DI PROTEZIONE SOPRA
STORAGE/SHOP
COPERTURA
ESTRADOSSO CLS
GROUND FLR
LOWER FLR
PIANO TERRA
SOTTOPAVIMENTO
SPRINKLER UPRIGHT
BRONZEO CON RETE
DI PROTEZIONE
SOPRA
STORAGE/SHOP
SIAMESE CONNECTOR TO BE UL LISTED OR FM APPROVED.
FINISHED IN BRASS.
THE LOCATION OF F.D CONNECTOR MUST BE ACCEPTED BY AHJ AND CHIEF FIRE INSPECTOR
FOR THE BASE.
WALL FLANGE W/ SYSTEM I.D.
ELEVATION VIEW
DRAIN 45° EL DOWN
GRADE/
CONCRETE SPLASH BLOCK
600mm MIN.
1100mm MAX.
ABOVE GRADECONCRETE SILL
PARASPRUZZI IN CLS
SOGLIA IN CLS
TERRENO
VISTA FRONTALE
FLANGIA A PARETE CON IL
DIAMETRO INTERNO
DELL'IMPIANTO
600mm MIN.
1100mm MAX
SOPRA IL TERRENO
GOMITO A 45°
COLLEGAMENTO SIAMESE CERTIFICATO UL O FM
FINITURA IN OTTONE
L'UBICAZIONE DEL COLLEGAMENTO PER I VV.F. DEVE ESSERE ACCETTATO
DALL'AUTORITA' PREPOSTA E DALL'ISPETTORE CAPO ANTINCENDIO DELLA BASE.
| FX001- FIRE PROTECTION SITE PLAN |
| FX101- FIRE PROTECTION FLOOR PLAN |
| FX102- FIRE PROTECTION DETAILS |
| FX103- FIRE PROTECTION DETAILS |
2012-04-26T10:35:50-0400
2012-04-26T10:36:26-0400
2012-04-26T10:36:27-0400
2012-04-26T10:36:28-0400
2012-04-26T10:37:03-0400
2012-04-26T10:37:43-0400
2012-04-26T10:37:44-0400
2012-04-26T10:37:46-0400
| 2012-05-08T12:24:04-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
| 2012-05-08T12:24:15-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
| 2012-05-08T12:24:18-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
| 2012-05-08T12:24:21-0400 | |
| Robert J. Tabet, P.E. | |
| I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed. |
2012-05-11T06:50:30-0400
2012-05-11T06:53:10-0400
2012-05-11T06:53:11-0400
2012-05-11T06:53:12-0400
File details come from the government source that posted it. Updated .