About this file

Part 10 FP

View the file

Other files

File Type Posted
UAS_SATCOM_RELAY_PADS_AND_FACILITY_11005.docx DOCX document
AMENDMENT_0011_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_0010_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_009_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_008_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_007_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
1118648_SPC_03-09-2015.pdf PDF
1118648_DWG_03-09-2015.pdf PDF
AMENDMENT_006_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
1118648_Amendment_2_Continuation_Sheet_2015-03-06.doc DOC document
AMENDMENT_005_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_004_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
PPI_015__Response_Attachments.pdf PDF
AMENDMENT_003_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
AMENDMENT_002_N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part03-CIV.pdf PDF
N62470-09-R9034_Part02-LS.pdf PDF
N62470-09-R9034_Part05-GEO.pdf PDF
11005R_SPECS_Final-EBS_04.13.12_Vol_1.pdf PDF
11005_SPECS_Final-EBS_04.13.12_Vol_2.pdf PDF
N62470-09-R9034_Part08-AR.pdf PDF
N62470-09-R9034_Part04-CIV_(CONT).pdf PDF
N62470-09-R9034_Part11-FP_(CONT).pdf PDF
N62470-09-R9034_Part09-IN.pdf PDF
N62470-09-R9034_Part06-LAND.pdf PDF
N62470-09-R9034_Part13-ME.pdf PDF
AMENDMENT_0001N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part14-EL.pdf PDF
N62470-09-R9034_Part07-ST.pdf PDF
N62470-09-R9034_Part12-PL.pdf PDF
N62470-09-R9034_Part01-GEN.pdf PDF
N62470-09-R9034_Part08-AR.pdf PDF
N62470-09-R9034_Part03-CIV-revised.pdf PDF
Contract_Risk_Assessment_and_QA_Responsibility_Spreadsheet-.pdf PDF
N62470-09-R9034_Part01-GEN.pdf PDF
N33191-15-R-0802_SATCOM_Relay_Pads.pdf PDF
N62470-09-R9034_Part04-CIV.pdf PDF
N62470-09-R9034_Part14-EL 1 .pdf PDF
11005R_SPECS_Final-EBS_04.13.12_Vol_1.pdf PDF
11005_SPECS_Final-EBS_04.13.12_Vol_2.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FI

RE

P

RO

TE

CT

IO

N

SI

TE

P

LA

N

FX001

1118648

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

N62470-09-R-9034 NOTA:NOTE /

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

As Indicated

14024777

RO

RT

F

BU

NO

M.

TE

NA

16616

ENG

D

NI EER

OL V

SEAL

S

A

SFORP

E H C

I

AL

OI N

OR L

T

KB

KB

IDRANTE

ANTINCENDIO

SCALE: 1:500

SITE LAYOUT PLAN1

LEGEND

FIRE HYDRANT

UNDERGROUND WATER MAIN

POST INDICATOR VALVE

THRUST BLOCK

FENCE

FINISHED FLOOR ELEVATION

2-1/2" SIAMESE FIRE DEPARTMENT CONNECTION

KB KEY BOX

IDRANTE ANTINCENDIO

PLANIMETRIA DEL SITO

CONDOTTA INTERRATA DI

COLONNINA INDICATRICE

BLOCCO REGGISPINTA

RECINZIONE

QUOTA PAVIMENTO FINITO

ATTACCO SIAMESE DA 2-1/2" PER COLLEGAMENTO VV.F.

ARMADIETTO PORTACHIAVI

LEGENDA

/ SCALA: 1:500

ADDUZIONE ACQUA

DI VALVOLA

1:500 GRAPHIC SCALE (METERS)

200 10

N

P

RO

TE

CT

IO

N

FL

OO

R

PL

AN

FX101

1118648

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

N62470-09-R-9034 NOTA:NOTE /

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

As Indicated

14024778

RO

RT

F

BU

NO

M.

TE

NA

16616

ENG

D

NI EER

OL V

SEAL

S

A

SFORP

E H C

I

AL

OI N

OR L

T

2-1/2" SIAMESE FIRE DEPARTMENT CONNECTION

UNDERGROUND FIRE WATER MAINS

POST INDICATOR VALVE

LEGEND

SPRINKLER RISER ASSEMBLY

SCALE: 1:100

FIRE PROTECTION FLOOR PLAN

FDC #1

ORDINARY HAZARD GROUP 1

LIGHT HAZARD

NON-SPRINKLERED AREA

SEE CIVIL FOR UG

ROUTING &

LOCATION OF PIV

ORDINARY HAZARD GROUP 2

FDC #2

GENERAL NOTES:

1. FINAL SPRINKLER PLACEMENT, PIPE ROUTING, AND QUANTITY SHALL BE COORDINATED

BETWEEN SPRINKLER CONTRACTOR AND GENERAL CONTRACTOR. DESIGN SHALL PROVIDE

MINIMUM ACCEPTABLE COVERAGE, FLOW, AND PRESSURE AS SPECIFIED UNDER NFPA 13

AND PER CONTRACT.

2. FIRE CONTRACTOR IS RESPONSIBLE FOR LOCATION OF TEST CONNECTION MEETING

LOCALLY ENFORCED CODE.

3. ALL VALVES SHALL BE READILY ACCESSIBLE FOR OPERATION.

4. ANY PORTION OF THIS SPRINKLER SYSTEM WHICH IS EXPOSED TO FREEZING SHALL BE

ADEQUATELY PROTECTED AGAINST THIS EXPOSURE. HEAT TAPE IS NOT ACCEPTABLE.

5. SPRINKLER RISER FEED FROM HAZMIN FIRE PUMPS RATED AT 4,731 LPM (1250 GPM) AT 5.17

BAR (75 PSI) SEE CU104 FOR CONNECTION AND LOCATION.

6. SPRINKLER SYSTEM TO BE INSTALLED PER NFPA 13 AND PER CONTRACT.

7. PROVIDE WET PIPE SPRINKLERS WITH A LIGHT HAZARD DENSITY OF 4.1 L/MIN/SQ. M FOR

280 SQ. METERS (0.10 GPM OVER 3,000 SQ. FT.). INCLUDES REDUCTION FOR QUICK

RESPONSE SPRINKLER AND LOW CEILINGS.

8. PROVIDE WET PIPE SPRINKLERS WITH ORDINARY GROUP 1 HAZARD DENSITY OF 6.1

L/MIN/SQ. M 280 SQ. METERS (0.15 GPM OVER 3,000 SQ. FT.) FOR RACK, HVAC AND TELECOM

ROOMS. INCLUDES INCREASE FOR SLOPED ROOF/CEILING.

9. PROVIDE WET PIPE SPRINKLERS WITH ORDINARY GROUP 2 HAZARD DENSITY OF 8.1

L/MIN/SQ. M 280 SQ. METERS (0.20 GPM OVER 3,000 SQ. FT.) FOR THE BOILER ROOM.

10. PIPE IN WET PIPE SYSTEM TO BE SCHEDULE 40 BLACK STEEL FOR THREADED PIPES

SMALLER THAN 50mm (2 INCHES) AND SCHEDULE 10 FOR GROOVED PIPE 50mm (2 INCHES)

OR LARGER.

11. PENDANT SPRINKLERS IN FINISHED ROOMS SHALL BE CONCEALED 155° F, K=5.6, QUICK

RESPONSE WITH A WHITE FINISH.

12. SPRINKLER SHALL BE CENTERED IN THE CEILING TILE, WITH A MINIMUM OF 150mm (6 INCH)

TO THE GRID.

13. UPRIGHT SPRINKLER SHALL BE 155° F, K=5.6 QUICK RESPONSE, BRONZE FINISH WITH WIRE

GUARDS.

14. GENERAL CONTRACTOR SEE SITE UTILITY PLAN SHEET CU104 FOR THE FIRE PUMP HOUSE

LOCATION.

LEGENDA

STRUTTURA MONTANTE SPRINKLER

TUBO INTERRATO ADDUZIONE ACQUA ANTINCENDIO

NOTE GENERALI:

1 . LA DISPOSIZIONE QUANTITA' E PERCORSO TUBAZIONI DEGLI SPRINKLER SARA'

COORDINATA FRA L'APPALTATORE DEGLI SPRINKLER E L'APPALTATORE

PRINCIPALE. IL PROGETTO DOVRA' PREVEDERE COPERTURA, FLUSSO E

PRESSIONE ACCETTABILI COME SPECIFICATO IN NFPA 13 E NEL CONTRATTO.

2. L'APPALTATORE DELL'ANTINCENDIO E' RESPONSABILE DELL'UBICAZIONE

DELL'ATTACCO DI PROVA IN ACCORDO CON LA NORMA APPLICABILE.

3. TUTTE LE VALVOLE SARANNO FACILMENTE ACCESSIBILI PER L'USO.

4. LE PARTI DI QUESTO IMPIANTO SPRINKLER CHE SIANO ESPOSTE AL GELO

SARANNO PROTETTE ADEGUAMENTE CONTRO TALE ESPOSIZIONE. IL NASTRO

SCALDANTE NON E' ACCETTABILE.

5. LA MONTANTE DEGLI SPRINKLER E' ALIMENTATA DA POMPE ANTINCENDIO DA

4.731 LPM (1250 GPM), 5.17 BAR (75 PSI). PER ATTACCO E UBICAZIONE VEDERE

CU104.

6. L'IMPIANTO SPRINKLER DEVE ESSERE INSTALLATO IN BASE A NFPA 13 E COME

DA CONTRATTO.

7. PROVVEDERE SPRINKLER A TUBO UMIDO CON UNA DENSITA' DI PERICOLO

LEGGERO DI 4.1 L/MIN/M2 PER 280M2 (0.15 GPM SU 3000 M2). INCLUDERE

RIDUZIONE PER RISPOSTA PRONTA SPRINKLER E SOFFITTI BASSI.

8. PROVVEDERE SPRINKLER A TUBO UMIDO CON UNA DENSITA' DI PERICOLO

GRUPPO 1 ORDINARIO DI 6.1 L/MIN/M2 PER 280M2 (0.15 GPM SU 3000 M2) PER

LOCALI RACK, HVAC E TELECOM. INCLUDERE MAGGIORAZIONE PER

TETTO/SOFFITTO INCLINATO.

9. PROVVEDERE SPRINKLER A TUBO UMIDO CON DENSITA' DI PERICOLO GRUPPO

2 ORDINARIO DI 8.1 L/MIN/M2.

10. I TUBI NEI SISTEMI A TUBO UMIDO DEVONO ESSERE IN ACCIAIO NERO SCH. 40

PER TUBI FILETTATI MINORI DI 50mm (2") O MAGGIORI.

11. GLI SPRINKLER A SOSPENSIONE NEI LOCALI FINITI DOVRANNO ESSERE DEL

TIPO NASCOSTO, 155° F, K=5.6, A RISPOSTA RAPIDA VERNICIATI BIANCHI.

12. GLI SPRINKLER DOVRANNO ESSERE INSTALLATI AL CENTRO DEI QUADROTTI

DEL SOFFITTO, CON UN MINIMO DI 150mm (6") DALLA GRIGLIA.

13. GLI SPRINKLER UPRIGHT DOVRANNO ESSERE PER 155° F, K=5.6, A RISPOSTA

RAPIDA. COLORE BRONZO CON RETE DI PROTEZIONE.

14. PER L'UBICAZIONE DELLE POMPE ANTINCENDIO L'APPALTATORE GENERALE

DEVE VEDERE LA PLANIMETRIA SERVIZI DEL SITO AL FOGLIO CU104.

PIANTA PROTEZIONE INCENDIO

ATTACCO SIAMESE DA 2-1/2" PER COLLEGAMENTO VV.F.

COLONNINA INDICATRICE DI VALVOLA

PERICOLO ORDINARIO GRUPPO 1

PERICOLO ORDINARIO GRUPPO 2

PERICOLO LEGGERO

AREA NON PROTETTA D ASPRINKLER

VEDERE DISEGNI CIVILI

PER PERCORSI INTERRATI

E UBICAZIONE PIV

/ SCALA: 1:100

KEY PLAN

1:100 GRAPHIC SCALE (MILLIMETERS)

50000 1000 2500 10000

A

N

SPRINKERED DI EDIFICIO

BUILDING SPRINKLERED

P

RO

TE

CT

IO

N

DE

TA

ILS

FX102

1118648

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

N62470-09-R-9034 NOTA:NOTE /

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

As Indicated

14024779

RO

RT

F

BU

NO

M.

TE

NA

16616

ENG

D

NI EER

OL V

SEAL

S

A

SFORP

E H C

I

AL

OI N

OR L

T

FDC

RISER CHECK VALVE

OS&Y VALVE W/

TAMPER SWITCH

TO SYSTEM

400mm X 600mm

MIN. SPLASH

BLOCK

50mm DRAIN AT

EXTERIOR

EXTERIOR

400mm X 600mm

PARASPRUZZI

F

45° GALV. ELBOW

CONCRETE SPLASH BLOCK

20mm DRAIN PIPE TO REMOTE

POINT ON SPRINKLER SYSTEM

SLOPE TO EXTERIOR OUTLET

ESCHUTEON

20mm BRONZE GLOBE VALVE

SECURE PIPE TIGHT TO WALL

SURFACE

GRADE/

CEILING/

PARASPRUZZI IN CLS

VALVOLA A GLOBO DA 20mm

IN BRONZO

TERRENO

ESCHUTEON

BORCHIA

CONTROSOFFITTO

13mm ORIFICE BRASS FITTING

CONCRETE SPLASH BLOCK

TO BRANCH LINE

ESCHUTEON

25mm UNION

25mm BRONZE GLOBE VALVE

SECURE PIPE TIGHT TO WALL

SURFACE

GRADE/

PACK WITH MINERAL WOOL &

CAULK WATERTIGHT

GIUNTO A 3 PEZZI

TERRENO

ESCHUTEON

AFFIX PERMANENT SIGN TO WALL

ADJACENT TO VALVE TO READ

SPRINKLER FLOW

TEST VALVE

SLOPE

PENDENZA

FLANGE CONNECTION

COLLEGAMENTO A FLANGIA

6mm X 32mm PIPE CLAMP MORSETTO TUBO 6mm X 32mm

BITUMASTIC PACKING -

MODULAR RUBBER SEAL

(OPTIONAL)

GUARNIZIONE BITUMINOSA-

SIGILLATURA MODULARE IN

GOMMA (OPZIONALE)

DUCTILE IRON

FEEDER PIPE

2 (16mm) COATED STEEL RETAINING ROD WITH (20mm) TIE BOLTS

6mm X 32mm IRON PIPE STRAP

FASCETTA TUBO IN FERRO

6mm X 32mm

EXTERIOR WALL

PARETE ESTERNA

WATER STOP

ALLOY BOLT (TYP.)

BULLONE IN LEGA (TIPICO)

FOLLOWER GLAND

PREMISTOPPA SUSSEGUENTE

RUBBER GASKET

GUARNIZIONE IN GOMMA

SLEEVE

MANICOTTO

FIXED RETAINER GLAND

PREMISTOPPA FISSO DI

FERMO

WATER SUPPLY

SLEEVE

MANICOTTO

CONCRETE SILL

NO OPENING CLEARANCE REQUIRED WITH SEISMIC FLEXIBLE COUPLINGS WITHIN 300mm

OF EACH SIDE OF MASONRY WALL, NOT REQUIRED FOR FRANGIBLE CONSTRUCTION

(GYPSUM BOARD)

FIRE RATED PUTTY IN ANNULAR SPACE OF

RATED WALLS, MIN THICKNESS/UL SYSTEM

MIN. 150mm THICK MASONRY WALL

STEEL PIPE MIN. SCHEDULE 10 MAX.

DIAMETER 600mm

TYPICAL 1 & 2 HR. RATED WALL PENETRATION, UL SYSTEM No WJ-1065 ATTRAVERSAMENTO TIPICO PARETE REI 60' E 120', OMOLOGAZIONE UL No WJ-1065

SEISMIC FLEXIBLE COUPLING

SEISMIC FLEXIBLE COUPLING

50mm CLEARANCE FOR PIPES OVER 90mm 25mm CLEARANCE FOR PIPES UP TO 90mm

FOAM BACKER ROD

VALVOLA OS&Y

CON DISPOSITIVO

ANTIMANOMISSIONE

ALL'IMPIANTO

VALVOLA DI RITEGNO

SCARICO DA 50mm

ALL'ESTERNO

ESTERNO

TUBO DI DRENAGGIO DA 20mm

DAL PUNTO PIU' LONTANO

DELL'IMPIANTO SPRINKLER IN

PENDENZA FINO AL PUNTO DI

USCITA ALL'ESTERNO

BORCHIA

FISSARE SALDAMENTE IL TUBO

ALLA SUPERFICIE DELLA

PARETE

GOMITO ZINCATO A 45° CON

LEVIGATURA

CEILING/ CONTROSOFFITTO

BORCHIA

BORCHIA

APPORRE UN SEGNO PERMANENTE

SULLA PARETE ADIACENTE ALLA

VALVOLA DA SEGNALARE

VALVOLA DI PROVA

OPERAZIONE SPRINKLER

FISSARE SALDAMENTE IL TUBO

ALLA SUPERFICIE DELLA

PARETE

PARASPRUZZI IN CLS

45° GALV. ELBOW W/ SMOOTH

GOMITO ZINCATO A 45° CON

LEVIGATURA

DIAFRAMMA CALIBRATO IN

OTTONE

VALVOLA A GLOBO DA 1" IN

BRONZO

RIEMPIRE CON LANA MINERALE E

SIGILLARE A TENUTA STAGNA

GIUNTO A TENUTA

STAGNA

TUBO IN GHISA

MALLEABILE

SOGLIA IN CLS

2 TIRANTI ANTIPERCUSSIONE DA

16mm IN ACCIAIO VERNICIATO CON

BULLONI DI SERRAGGIO M18

ADDUZIONE

ACQUA

MASTICE ANTINCENDIO NELLO SPAZIO

ANULARE DELLA PARETE REI, SPESSORE

MINIMO COME OMOLOGATO UL

GIUNTO FLESSIBILE

ANTISISMICO

LUCE NETTA 25mm PER TUBI FINO A 90mm LUCE NETTA 50mm PER TUBI > DI 90mm

GIUNTO FLESSIBILE

ANTISISMICO

PARETE IN MURATURA

SPESS. MIN. 150mm

TUBO IN ACCIAIO SCH. 10 MIN.

DIAMETRO MAX 600mm

GIUNTO FLESSIBILE

ANTISISMICO

NESSUNA APERTURA NETTA CON GIUNTI FLESSIBILI E' RICHIESTA ENTRO 300mm DI CIASCUN

LATO DELLA PARETE IN MURATURA. NESSUNA RICHIESTA PER COSTRUZIONI FRAGILI

(LASTRE DI CARTONGESSO)

OAKUM PACKING (OMIT IF

RUBBER SEAL IS USED)

GUARNIZIONE IN CANAPA

(DA OMETTERE SE E' USATA

LA SIGILLATURA IN GOMMA)

NTS

RISER DIAGRAM

FLOOR

150mm (6")

50mm DRAIN TO EXTERIOR

6" UNDERGROUND SUPPLY WITH

RETAINING RODS

PRESSURE GAUGE

RISER CHECK VALVE

FLOW SWITCH

NTS

RISER ROOM LAYOUT

OS&Y VALVE W/ TAMPER SWITCH

GRADE

SCHEMA

MANOMETRO

CONCRETE

SPLASH BLOCK

PARASPRUZZI

IN CLS

FDC

CHECK VALVE W/

BALL DRIP TO

EXTERIOR

VALVOLA DI

RITEGNO A SFERA

ANTIGOCCIA

ALL'INTERNO

TO WET SYSTEM

WIRE TO FIRE

ALARM PANEL

/ PAVIMENTO

/ NON IN SCALA / NON IN SCALA

TERRENO

CAVO DI

COLLEGAMENTO AL

QUADRO ALLARME

ANTINCENDIO

ALL'IMPIANTO AD

UMIDO

FLUSSOSTATO

VALVOLA DI RITEGNO

SCARICO DA 50mm

ALL'ESTERNO

VALVOLA OS&Y CON DISPOSITIVO

ANTIMANOMISSIONE

TUBO DI ADDUZIONE DA 150mm CON

TIRANTI ANTIPERCUSSIONE

SCHEMA LOCALE

1 2

NTS

TYPICAL LOW POINT DRAIN

NTS

TYPICAL WET PIPE TEST DRAIN

/ NON IN SCALA

/ NON IN SCALA

PUNTO BASSO DRENAGGIO DRENAGGIO DI PROVA

4 5

NTS

TYPICAL WALL PENETRATION DETAIL

/ NON IN SCALA

PARETE

PARTICOLARE ATTRAVERSAMENTO

NTS

RISER DETAIL

/ NON IN SCALA

ADDUZIONE

PARTICOLARE SCHEMA

FX103

R

E

PR

O

TE

C

TI

O N

D

ET

AI

L

1118648

1 2

PM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A

B

C

D

1 2 3 4 5

3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

OF

EPROJECT NO.:

DRAWFORM REVISION: 10 MARCH 2009

N62470-09-R-9034 NOTA:NOTE /

IF THIS DRAWING IS LESS THAN 841 X 594mm

IT IS A REDUCED SIZE DRAWING

SE QUESTO DISEGNO E' PIU' PICCOLO DI 841 X 594mm

E' UN DISEGNO A DIMENSIONI RIDOTTE

As Indicated

14024780

RO

RT

F

BU

NO

M.

TE

NA

16616

ENG

D

NI EER

OL V

SEAL

S

A

SFORP

E H C

I

AL

OI N

OR L

T

NTS

SECTION

GROUND FLR

T.O CONC

ROOF

LOWER FLR

WHITE CONCEALED

SPRINKLER3660mm (144")

SEZIONE

13 2

COPERTURA

ESTRADOSSO CLS

PIANO TERRA

SOTTOPAVIMENTO

/ NON IN SCALA

SPRINKLER BIANCO

NASCOSTO

WHITE CONCEALED

SPRINKLER

3250mm (128") SPRINKLER BIANCO

NASCOSTO

NTS

F.D CONNECTION

/ NON IN SCALA

COLLEGAMENTO VV.F.

NTS

SECTION

BRONZE UPRIGHT

SPRINKLERS W/

GUARDS OVER

STORAGE/SHOP

BRONZE UPRIGHT SPRINKLERS W/

GUARDS OVER HVAC/BOILER

T.O CONC

ROOF

SEZIONE

13 2

/ NON IN SCALA

SPRINKLER UPRIGHT BRONZEO CON

RETE DI PROTEZIONE SOPRA

STORAGE/SHOP

COPERTURA

ESTRADOSSO CLS

GROUND FLR

LOWER FLR

PIANO TERRA

SOTTOPAVIMENTO

SPRINKLER UPRIGHT

BRONZEO CON RETE

DI PROTEZIONE

SOPRA

STORAGE/SHOP

SIAMESE CONNECTOR TO BE UL LISTED OR FM APPROVED.

FINISHED IN BRASS.

THE LOCATION OF F.D CONNECTOR MUST BE ACCEPTED BY AHJ AND CHIEF FIRE INSPECTOR

FOR THE BASE.

WALL FLANGE W/ SYSTEM I.D.

ELEVATION VIEW

DRAIN 45° EL DOWN

GRADE/

CONCRETE SPLASH BLOCK

600mm MIN.

1100mm MAX.

ABOVE GRADECONCRETE SILL

PARASPRUZZI IN CLS

SOGLIA IN CLS

TERRENO

VISTA FRONTALE

FLANGIA A PARETE CON IL

DIAMETRO INTERNO

DELL'IMPIANTO

600mm MIN.

1100mm MAX

SOPRA IL TERRENO

GOMITO A 45°

COLLEGAMENTO SIAMESE CERTIFICATO UL O FM

FINITURA IN OTTONE

L'UBICAZIONE DEL COLLEGAMENTO PER I VV.F. DEVE ESSERE ACCETTATO

DALL'AUTORITA' PREPOSTA E DALL'ISPETTORE CAPO ANTINCENDIO DELLA BASE.

FX001- FIRE PROTECTION SITE PLAN
FX101- FIRE PROTECTION FLOOR PLAN
FX102- FIRE PROTECTION DETAILS
FX103- FIRE PROTECTION DETAILS

2012-04-26T10:35:50-0400

2012-04-26T10:36:26-0400

2012-04-26T10:36:27-0400

2012-04-26T10:36:28-0400

2012-04-26T10:37:03-0400

2012-04-26T10:37:43-0400

2012-04-26T10:37:44-0400

2012-04-26T10:37:46-0400

2012-05-08T12:24:04-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.
2012-05-08T12:24:15-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.
2012-05-08T12:24:18-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.
2012-05-08T12:24:21-0400
Robert J. Tabet, P.E.
I, Robert J. Tabet, P.E., am signing this document to confirm that it has been reviewed.

2012-05-11T06:50:30-0400

2012-05-11T06:53:10-0400

2012-05-11T06:53:11-0400

2012-05-11T06:53:12-0400

File details come from the government source that posted it. Updated .