J-1601000-04 Utility Map Attributes.xlsx

XLSX spreadsheet 59 KB Posted

Attached to
Base Operations Support (BOS) Services at U. S. Naval Air Station (NAS) Sigonella and its outlying support activities, Sicily, Italy
Solicitation number
N6247025R0020
Issued by

About this file

This document is a detailed technical specification file for a utility map attributes data interface, specifically focused on file transfer and data mapping processes for inserting or updating Facilities/UEM Assets records. The file describes a complex inbound data transfer process involving pipe-delimited text files, with specific protocols for file handling, conversion, and error management across multiple server directories. Key technical details include automatic file placement in specific interface folders, conversion processes managed by cron tasks, and a precise data mapping specification that defines required fields such as Asset Number, Site ID, Class Structure ID, and various attribute specifications with validation rules.

The interface is designed to process inserts and updates into an ASSETSPEC table, with strict validation requirements for data fields including domain value checks and specific rules for numeric and alphanumeric value population. Error handling is comprehensive, with provisions for creating .processed, .error, and .log files to track successful and failed record transfers. The specification includes sample data demonstrating the expected file format, with guidelines specifying that pipe-delimited files should not start with a pipe character and must end with a final pipe delimiter. While the file appears to be a technical specification for a data transfer interface, it is not directly related to the referenced federal contract opportunity for Base Operations Support Services at Naval Air Station Sigonella in Sicily, Italy.

View the file

Other files

File Type Posted
Solicitation Amendment N6247025R00200012 SF 30.pdf PDF
J-14 PPI Responses (Ament 0010).pdf PDF
J-1606001-03 Water System Description and Inventory - Amend 0010.xlsx XLSX spreadsheet
Annex 1601000 C Utility Management - Amend 0008.pdf PDF
Annex 1602000 C Electrical - Amend 0008.pdf PDF
J-13 PPI Responses (Ament 0008).pdf PDF
J-10 Pre-Proposal Site Visit Sign-In Sheet (Amend 0007).pdf PDF
J-11 Pre-Proposal Conference Presentation Sigonella BOS (Amend 0007).pdf PDF
J-1502000-05 Base Systems Description RFP - Amend 0007.xlsx XLSX spreadsheet
J-1503030-06 Solid Waste Containers Inventory - Amend 0007.xlsx XLSX spreadsheet
J-1606001-03 Water System Description and Inventory Amend 0007.xlsx XLSX spreadsheet
Solicitation Amendment N6247025R00200005 SF 30.pdf PDF
Attachment J-9- PPI Responses.pdf PDF
J-4 Pre-Award Inquiry Form (AMD 0001).xlsx XLSX spreadsheet
J-2 Corporate Experience Project Data Sheet.pdf PDF
J-4 Pre-Award Inquiry Form.xlsx XLSX spreadsheet
J-7 Communicazione Antimafia self-cert form.pdf PDF
J-8 Informazione Antimafia self-cert form.pdf PDF
Annex 1503020 Pest Control.pdf PDF
Annex 1604000 Wastewater.pdf PDF
Annex 1606001 Water (Overseas).pdf PDF
Annex 1700000 Transportation.pdf PDF
J-0200000-06.a - ASSET SPECIFICATION.xlsx XLSX spreadsheet
J-0200000 -12 ELINs Sigonella.xlsx XLSX spreadsheet
J-1402000 Unaccompanied Housing.pdf PDF
J-1502000-06 DHA Systems Descriptions.xlsx XLSX spreadsheet
J-1502000-07.d Vehicle Fueling Station Equipment Description.xlsx XLSX spreadsheet
J-1503010-06.a Custodial Inventory and Frequencies.xlsx XLSX spreadsheet
J-1503020-04 Sigonella IPMP 2024.pdf PDF
J-1503050-02.b Eucalyptus Trees Inventory.xlsx XLSX spreadsheet
J-1503050-06 BASH Requirements and Site Map.pdf PDF
J-1503050-07 NASSIG WHA.pdf PDF
J-1503050-08 Exterior Containers Inventory.xlsx XLSX spreadsheet
J-1601000-08 Utility Asset Inventory.xlsx XLSX spreadsheet
J-1604000-03 Wastewater Systems Description and Inventory.xlsx XLSX spreadsheet
J-1606001-04 Historical Critical Spare Parts Inventory.xlsx XLSX spreadsheet
J-1606001-06 Unidirectional Flushing Plan NAS I.pdf PDF
Section F Deliverables.pdf PDF
J-1 Past Performance Questionnaire (Form PPQ).pdf PDF
Annex 0100000 General Information.pdf PDF
Annex 1401000 Family Housing.pdf PDF
Annex 1402000 Unaccompanied Housing.pdf PDF
Annex 1503010 Custodial.pdf PDF
Annex 1503050 Grounds Maintenance and Landscaping.pdf PDF
Annex 1602000 Electrical.pdf PDF
J-0200000 Management and Adminstration.pdf PDF
J-1401000 Family Housing.pdf PDF
J-1501000 Facility Management.pdf PDF
J-1502000 Facility Investment.pdf PDF
J-1502000-04 Bldg 273 Critical Areas Requiring ICRA.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

File Transfer

J-1601000-04_Utlity Map Attributes
Interface:Specification File
File Transfer
Current as of April 4, 2012

Purpose: Insert or update Facilities/UEM Assets records with specifications

Type: Inbound

Arctic OEM Job: TBD
Frequency: TBD

Cron Task: ConvertFileImport

Cron Task Instance: SpecificationFile_<SITEID>

File Format: Pipe Delimited (.txt)
File Transfer Process:

1. File is received from FEC and automatically placed in the site-specific SpecificationFile interface folder (<server> /wsbin01/app/integration/assetfile/<SITEID>) with a Permission Mode value of 640. Note: When manually copying an interface file to its corresponding site-specific folder, the Permission Mode value needs to be set to 644.

2. When picked up by the SpecificationFile_<SITEID> Cron it is converted into a pipe delimited (.txt) file. The new .txt file is placed in the server's /wsbin01/app/integration/Global/PipedFiles/ folder.

3. Once the .txt file is created the string ".processed" is appended to the original file located in the server's /wsbin01/app/integration/assetfile/<SITEID> folder.

4. The Cron Task Instance Specification Interface (under Cron Task "ConvertFileImport") will process the newly created .txt file. The .processed file is placed in the server's /wsbin01/app/integration/global/PipeFiles/backup folder when done.

Error Handling:Yes - error log and log file both created when a bad record is found
Any other kind of error handling (such as Message Reprocessing, other file mentioned in the Business Logic tab, et al?

J-1601000-05_Utility Map Attributes N62470-17-D-4012 &KFF0000A0051 19-Nov-2021

Data Mapping

Interface: Asset File
Data Mapping
Current as of February 28, 2012
Design ID:
Requirement ID:
Site Specific: Yes
Cron Task: ConvertFileForImport
Cron Task Instance: assetspecfile_<SITEID>
Type: Inbound
Source File Format: Pipe Delimited (.txt)
Converted File Format: N/A

Note: All other TABLE.COLUMN contents and/or field values not listed below are NULL on insert.

Source File and Source Code
NamePositionLengthStartStopReq'dNotesMaximo 7
ApplicationTitle - Field NameTabTableColumnTypeValueValidated against DOMAINInsertUpdatePopulated ByNotesRqmt IDHPQC
Asset125N/AN/AYESAssetAssetSpecificationASSETASSETNUMVARCHAR2(25)NONO
siteid28N/AN/AYESAssetAssetSpecificationASSETSITEIDVARCHAR2(8)NONO
CLASSSTRUCTUREID320N/AN/AYESnot shown on front endN/AN/AN/AASSETSPECCLASSSTRUCTUREIDVARCHAR2(20)NONO
Attribute4300N/AN/AYESAssetAttributeSpecificationASSETSPECASSETATTRIDVARCHAR2(300)NONO
Numeric Value540N/AN/ANOonly one value can be pased Numeric or AlphaNumericAssetNumeric ValueSpecificationASSETSPECNUMVALUENUMBER(30,10)possiblyNOYESInterface
Alphanumeric6254N/AN/ANOonly one value can be pased Numeric or AlphaNumericAssetAlphanumericSpecificationASSETSPECALNVALUEVARCHAR2(254)possiblyNOYESInterface
Unit of Measure78N/AN/ANOmust match domainAssetUnit of MeasureSpecificationASSETSPECMEASUREUNITIDVARCHAR2(8)yesNOYESInterface
Display Sequence810N/AYESInteger valueAsset SpecN/AN/AASSETSPECDISPLAYSEQUENCESMALLINT(10)noYESYESInterface8099
Linear Asset Spec ID912N/AYESInteger valueAsset SpecN/AN/AASSETSPECLINEARASSETSPECIDINTEGER(12)noYESYESInterfaceShould always be 0 unless client is using Linear8099
AssetChanged byAssetASSETCHANGEBYVarchar(30)userinterfaceInterface
Assetchange dateASSETCHANGEDATEDateserver dateInterface

J-1601000-05_Utility Map Attributes N62470-17-D-4012 &KFF0000A0051

Business Logic

Business Logic
LogicDescriptionAdditional Notes
Interface processesInserts and Updates into ASSETSPEC table (no modification of CLASSSPEC, i.e., don't touch templates)
SITEIDIncluded in Source File
Required FieldsASSETNUMRequired fields not provided in the source file will be rejected via .error/.log ConvertFileForImport process
SITEID
CLASSSTRUCTUREID
ASSETATTRID
ValidationASSETNUM + SITEID
CLASSSTRUCTUREID
If the AssetNum + SiteID + Classification doesn't exist, then the interface will create the associated specification record.Note: There must be an asset and classification populated before a specification is created.
ALN and/or NUMERIC value depending on what is populated in the source file. These fields can be null individually; however, not both null. Not all attributes have domain lists for the Alphanumeric and Numeric Values; the MIF will validate the individual ALN or NUMERIC domain values and throw the rejects to MRP.
The value in ASSETATTRIBUTE.DATATYPE specifies if attribute can be updated with Alphanumeric value or Numeric value
VALUE UOM
ASSET.CHANGEBY populated by INTERFACE (not in the source)
ASSET.CHANGEDATE populated by server date (not in the source)
On UPDATE, data will be validated against domain lists when one exists for that data field; if data is not valid, record will not be updated and will be written to the error logs
If multiple attributes are to be updated on the same asset then a new record should be created for each attribute update
DISPLAYSEQUENCE will be created only for inserted records. It will grab the next sequence #. Updates will not affect this field.
Error HandlingIf Successful, source file will be named .processed in the SOURCEDIRECTORY

If Failed, .processed, .error and .log files will be created.

1) The .processed will contain all records that were successfully processed. Processed files shall be named with .datetime .processed extension.

2) The .error will contain the original transaction with the error.

3) The .log will contain the error message.

Message ReprocessingIf the MBO cannot validate a value that comes in from the source (e.g. Invalid GL, Location etc.,) it will throw this error in Message Reprocessing. This is separate from the error handling that addresses issues with the original source file above.
Additional RequirementsIgnore Status and Change Date. Let the MIF construct these.
Business Logic
Current as of Februrary 28, 2012
Rqmt IDDescriptionComments -Matt's comments
TBDFlat file named Specification_FECID_DATETIME.txt shall be provided by the FEC in /assetfile/FECID on the Arctic server
TBDFile will be picked up and moved over to the Maximo Server (Adria) by OEM job created by NITC
TBDData should be in a pipe delimited file in the format specified in the Specification(F12)DataMapping tab (required fields, order, type, length)See "Data Mapping" tab for list of required values.
TBDAny record missing a required data field shall be written to the error log named SpecificationFile_FECID_ErrorLog.txtShouldn't this really be just written to the .error and .log files we create in preprocessing with the ConvertFileForImport cron task?
TBDAssetNum, SiteId and Classstructureid must match for a record to be updated; on failure record should be written to error logsSo just to be clear, if this combination doesn't already exist in Maximo, we are not to create the Asset Specification record? We are just associating existing Asset Specifications with Asset records, right?If the AssetNum + SiteID + Classification doesn't already exist, I create it.
TBDNot all attributes have domain lists for the Alphanumeric and Numeric Values; must verify if domain list exists for that attribute; if one exists the data must be validated against the domain list
TBDOn update data will be validated against domain lists when one exists for that data field; if data is not valid, record will not be updated and will be written to the error logs
TBDAny record failing domain validation shall be written to the error log named SpecificationFile_FECID_LogFile.txt
TBDAny record written to the error log shall have a corresponding error message written in the log file with an explanation as to why the record failed validation
TBDThe error log file & log file shall be placed in xxxx directory on xxxx server for FEC review
TBDInterface will create SpecificatoinFile_FECID_DateTime.txt file inserting additional required data fields updated by the system without frontend input. Those fields from the asset table are defined in the data mapping document under the Maximo 7 application portion
TBDInnterface shall update the ASSETSPECHIST table shall be updated with data added to asset recordMbo handles this
TBDThe value in ASSETATTRIBUTE.DATATYPE specifies if attribute can be updated with Alphanumeric value or Numeric value
If multiple attributes are to be updated on the same asset then a new record should be created for each attribute update
TBDOnly one of the two values can be populated Alphanumeric or Numeric
TBDIf both are left blank should any exsitsing data be blanked out or should the record be rejected and written to error log?Question for usersI am rejecting the record in this scenario and creating the .log/.error files
TBDProcessed files shall be named with .datetime .processed extension.

J-1601000-05_Utility Map Attributes N62470-17-D-4012 &KFF0000A0051

Sample Data

Sample Data
Current as of February 22, 2012

*Please do not include a | as the first character in the source and end the record with a final |

3-440-EPN-007|11001|1616|UAMETERDEVICEID||A1234||
3-440-EPN-007|11001|1616|AMRINDICATOR||No||
3-440-EPN-007|11001|1616|PTRATIO|36||BA|
INTTEST1|10401|1014|HP|250||CC|

J-1601000-05_Utility Map Attributes N62470-17-D-4012 &KFF0000A0051